Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680869_1Bid Award Id
ViewTender No
8899/ E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
22
-
-
Surface dressing not exceeding 15cm deep and getting out in soft/loose soil complete all as specified and as directed
190
-
-
Excavating in post holes (or similar holes) each not exceeding 0.5cum, returning, filling in, getting out in soft / loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance not exceeding 50m complete all as specified and as directed
31
-
-
M&L for hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, using broken stone or boulders complete all as specified and as directed
21
-
-
B/R WORKS
-
-
-
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed
65
-
-
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and as directed
80
-
-
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 200mm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 50mm but n exceeding 100mm wide complete all as specified and as directed
460
-
-
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
1500
-
-
M&L for mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
570
-
-
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders securing with clips complete all as specified and as directed
500
-
-
S&F in position steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer, etc. using ERW or induction butt welded tubes / SHS conforming to IS-1161-2014 / IS-4923-1997 grade St-240 complete all as specified and as directed
1400
-
-
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed
4
-
-
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed
300
-
-
M&L for providing RCC design mix M-25 as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles, mass concrete, etc. complete all as specified and as directed
8
-
-
M&L for providing RCC design mix M-25 as in columns, posts, piers, pillars, struts, etc. complete all as specified and as directed
4
-
-
M&L for providing RCC design mix M-25 as in beams, cantilevers, lintels, etc. over 1.5m long complete all as specified and as directed
4
-
-
Notes for serial item Nos. 18 to 20: (a) Mix design shall be conforming to relevant IS. Design mix shall be got designed from National Test House, SEMT Wing CME, Regional Research labs, IITs, National Institutes of Technology, Command Test Laboratory and Govt Engineering Collage and shall be got approved by the GE. Cost of obtaining design mix shall be included in the quoted rates
(b) The Contractor shall use only one type brand of cement for entire structural/reinforced concrete work. In the event of contractor desiring use of any different brand of cement, fresh design mix shall be
carried out and submitted for approval without any extra cost to the Govt.
(c) Reinforcement steel will be measured separately under respective items herein
-
-
-
M&L for 40mm thick plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregates) as in sub-base, flooring, etc. complete all as specified and as directed
112
-
-
M&L for pre-cast plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregates) as in plain faced covers, etc. including all mouldings, formwork, etc. set in CM 1:6 complete all as specified and as directed
0.25
-
-
M&L for plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregates) as in benching with rounded or chamfered edges, including all formwork, etc. complete all as specified and as directed
1.2
-
-
M&L for 75mm thick plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in floors, sub-bases, pavings, etc. surface finished rough complete all as specified and as directed
182
-
-
M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate for bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm dia drain pipes complete all as specified and as directed
70
-
-
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregates as in foundation filling, mass concrete, etc. complete all as specified and as directed
6.6
-
-
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directed
Note: Inner girth shall only be measured
4.5
-
-
M&L rendering 15mm thick, in cement mortar (1:6) on walls / concrete surfaces, etc. finished even and fair without using extra cement complete all as specified and as directed
100
-
-
M&L rendering 15mm thick, in cement mortar (1:4) on walls / concrete surfaces, etc. in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished even and fair without using extra cement complete all as specified and as directed
Note: WPC will be measured and paid separately under respective item herein
335
-
-
Supply only integral water proofing compound all as specified
90
-
-
M&L for 10mm thick backing coat in CM (1:4) finished rough to receive wall tiles, etc. complete all as specified and as directed
305
-
-
M&L for 15mm thick screed bed or bedding layer in CM (1:6) finished rough to receive floor finish complete all as specified and as directed
90
-
-
S&F solid PVC door frame of size 50x47mm made out of 5mm thick plain / printed coloured PVC sheet (as approved) reinforced with MS square tube all as per specifications and drawing given in SSR Part-I 2009 all as per manufacturer's instructions and making good the disturbed surfaces complete all as specified and as directed
85
-
-
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width, stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2020) complete all as specified and as directed
22
-
-
S&F in position 2 way sliding anodized aluminium glazed ventlator shutter with frame as detailed hereinbelow complete all as specified and as directed
(a) Ventillator frame 2 track of size 60x25x1.5mm thick
(b) Stiles and rails of size 35x25x1.5mm thick
(c) T section mullion 35x35x1.5mm thick
(d) 4mm thick tinted glass duly fixed with PVC gasket allround
(e) 2Nos. of aluminium anodized handles 100mm
(f) Area of opening shall be measured for measurement purposes. All necessary fittings, fixtures, etc. shall be deemed to be included in the quoted rate
7.5
-
-
S&F 100mm long stainless steel butt hinges of selected quality, with stainless steel hinge pin fixed with stainless steel screws complete all as specified and as directed
54
-
-
S&F 150mm extruded aluminum alloy handles, fabricated 'D' type, anodized complete all as specified and as directed
36
-
-
S&F 200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed
36
-
-
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
170
-
-
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
30
-
-
M&L for suspended false ceiling using E-grid 2430, 180GSM (exposed ceiling suspension system) as per IS-14862, of grid size 600x600mm with main runner 38x24mm and wall angle 24x24mm using 4mm thick high pressure stean crude non-asbestos fiber cement plain board in a grid of GI system duly suspended with 4mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning vents, diffuser and ducts, sprinkler, smoke detectors, etc., main runners secured to structural soffits by hanger @1220mm maximum c/c and the last hanger at the end of each main runner placed at more than 450mm from the adjucent wall, flush fitting 1220mm cross tee interlocked between main runners @610mm c/c forming 600x600mm grid and painting with two coats of acrylic emulsion paint (of approved shade) over a coat of cement primer before installing it on the grid complete all as specified and as directed
90
-
-
M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
80
-
-
M&L for preparation of new plastered surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungus resistant, dirt resistant, exterior paint (of approved tint, company depot tinted) with silicon additives @1.43litre/10sqm over a priming coat of exterior primer applied @0.90litre/10sqm complete all as specified and as directed
335
-
-
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.06sqm but not exceeding 0.11sqm each, 7 to 8mm thick of superior quality as in floors, etc. set and jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed
90
-
-
M&L for glazed ceramic tiles, coloured, of size 450x300mm, 6 to 7mm thick, of superior quality as in vertical surfaces, skirting, dado, etc. pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed
305
-
-
S&F wash hand basin, vitreous China, oval shaped, white, flat back type, of size 550x400mm, including CI brackets, cutting for and pinning in ends of brackets with coupling and including PVC connection 60cm key with brass union complete all as specified and as directed
14
-
-
S&F vitreous China wash down water closet pan (Pedestal pattern), coloured (as approved), with 'P' or 'S' trap, including flush pipe, trap, connection to drain or outgoing pipe, anti-syphonic pipe, seat cover to match with colour of WC, closed pattern with flat bottom & cover and chromium plated mild steel or aluminum anodized hinge device and jointing and connecting up complete all as specified and as directed
12
-
-
S&F urinal spreader of PTMT any colour for fixing with 15mm dia pipe of minimum weight 60gms) complete all as specified and as directed
10
-
-
S&F vitreous China half stall type urinal, flat back, of size of 375x390x590mm, white with grating and union for discharge pipe (back or corner wall type), including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal with plugs with 60mm long brass screws, pointing around urinal back in cement, with and including and fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and as directed
10
-
-
S&F 15mm bib taps, chromium plated, cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
13
-
-
S&F 15mm dia pillar taps, fancy type, cast copper alloy, with capstain heads, chromium plated, screwed down, high pressure, with or without lettered 'HOT'/'COLD', with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed
14
-
-
S&F 15mm dia stop cocks / angle valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed
38
-
-
S&F chromium plated mild steel soap dish of approved design, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed
14
-
-
S&F towel ring, PTMT, 9'' dia, fixed with chromium plated screws and wooden/PVC rawl plugs, minimum weight 90gm, of approved design and type complete all as specified and as directed
12
-
-
S&F towel ring, stainless steel, chromium plated, 9'' dia, fixed with chromium plated screws and wooden/PVC rawl plugs, of approved design and type complete all as specified and as directed
12
-
-
S&F stainless steel chromium plated toilet paper holder with flap of approved design and pattern fixed on wall with chromium plated screws complete all as specified and as directed
12
-
-
S&F health faucet, 15mm bore, brass head chromium plated, telephone type, with CP arms, flexible pipe (ABS body) with 1.2m long stainless steel flexible braided hose tube and PTMT wall hook / hanger of approved finish complete all as specified and as directed
12
-
-
S&F brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed
24
-
-
S&F 15mm PVC connections, 450mm long with PTMT couplings, PTMT nuts, etc. complete all as specified and as directed
36
-
-
S&F waste coupling PTMT (half or full threaded), minimum weight 45gms suitable for 32mm bore discharge pipe complete all as specified and as directed
22
-
-
S&F 600x450mm full sized bevelled edge mirror of selected quality glass mounted on 9mm thick AC building board or commercial plywood PVC moulded at edges and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed
14
-
-
S&F steel water tubing, 15mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed
105
-
-
S&F steel water tubing, 20mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed
160
-
-
S&F PVC pipes, 150mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps or laid in trenches, etc. complete all as specified and as directed
95
-
-
S&F PVC (SWR) pipes, 110mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, etc. complete all as specified and as directed
45
-
-
S&F PVC (SWR) pipes, 75mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, etc. complete all as specified and as directed
36
-
-
S&F 110mm bore PVC (SWR) bend of any radius complete all as specified and as directed
12
-
-
S&F 75mm dia PVC (SWR) 'P' floor trap with chromium plated grating jointed with solvent cement complete all as specified and as directed
18
-
-
E/M WORKS
-
-
-
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed
Note: Only punned thickness of sand shall be considered for measurement purposes
14
-
-
Supply and laying burnt bricks of sub-class 'B' designation 75 of size 230x115x75mm laid in trenches for cable protection complete all as specified and as directed
1080
-
-
S&F steel water tubing, light grade, 40mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches as in cable protection, etc. complete all as specified and as directed
30
-
-
M&L for point wiring with 1.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories with MS sunken box, concealed in walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly complete all as specified and as directed for the following:
-
-
-
One light point controlled by one 5A one way switch
47
-
-
One ceiling fan / exhaust fan point controlled by one 5A one way switch
14
-
-
One switch socket outlet 3 pin 5A controlled by one switch on independent board
7
-
-
One switch socket outlet 3 pin 5A controlled by one switch on same board
1
-
-
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
32
-
-
S&F switch piano flush button type, single pole, ISI marked, one way 5A, 240V complete all as specified and as directed
62
-
-
S&F switch socket outlet, 5 pin, 5A flush type, ISI marked, 240V complete all as specified and as directed
1
-
-
S&F switch socket combination outlet, 5 in 1, 5A flush type, ISI marked, 240V complete all as specified and as directed
7
-
-
S&F PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder with back plate 240V complete all as specified and as directed
7
-
-
S&F bulk head fitting LED, 10W, with pressure die cast housing, acrylic diffuser with frame and connecting accessories and connecting up complete all as specified and as directed
17
-
-
S&F LED linear light fitting, 1x20W, 220V AC decorative batten type, wall mounting with polycarbonate housing, integrated electronic driver, all accessories pre-wired including and 20WLED bulb/lamp and connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
21
-
-
S&F LED street / building security light luminaire 30W, IP-66, with LED driver, etc. with all accessories prewired and 30W LED lamp including service bracket complete all as specified and as directed
2
-
-
S&F LED bulb / lamp 10W, 5 star rated, B22 and connecting to lamp holder complete all as specified and as directed
7
-
-
S&F heavy duty, PVC body with PVC blades, legs, ISI marked energy efficient exhaust fan, 250mm sweep, 230V, 50Hz, 1200RPM, copper wound, with louvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts complete all as specified and as directed
14
-
-
Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductors, 1100V grade 2 core 10sqmm laid in trenches/fixed to wall/under road/drawn through pipes etc. with copper cable glands and copper thimbles conforming to IS-7098 (Part-I) 1988 complete all as specified and as directed
180
-
-
S&F sheet metal enclosures 4 way MCB DB, 240V, SPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed/grouted in wall and making good the disturbed surfaces complete all as specified and as directed
6
-
-
S&F MCB isolator SPN, 240V, 40A, 10kA, 50Hz, C curve complete all as specified and as directed
6
-
-
S&F MCB SP, 240V, 6 to 40A, 10kA, 50Hz, C curve complete all as specified and as directed
12
-
-
M&L for earthing using GI earthing wire with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x600x600mm with 10mm thick CI earth pit cover with handle, duly hinged in mild steel angle iron frame of size 300x300x300mm made out of MS angle iron of size 40x40x6mm thick duly fixed to existing earthing pits and entirely painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
6
-
-
Notes for serial item No. 93: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included
(ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
-
-
-