Military Engineer Services Tender
View complete overview of Mizoram MES Tender
Costs
EMD
₹ 76,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_696578_1Tender No
8936/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed
Note: Only punned thickness of sand shall be considered for measurement purposes
93
-
-
... More
Supply and laying burnt bricks of sub-class 'B' of size 230x115x75mm laid in trenches for cable protection complete all as specified and as directed
13574
-
-
... More
M&L for plain cement concrete 1:2:4 (type B-1) using 20mm graded stone aggregate as in coping for erected pole, repair of road cuttings , etc. complete all as specified and as directed
2
-
-
... More
Supply,install, test and commissioning LT panel outdoor, floor mounted/pedestal type, cubical, self supported, CPRI approved make, front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides IP 52 protection with dust and vermin proof etc, fabricated out of 3.15mm CRCA sheet duly powder coated, mounted/fixed on and including MS angle iron stand of 1 Mtr height( 50Cm above FFL and 50Cm below FFL), fabricated out of 50x50x6mm thick MS angles duly painted with two coats of black enamel synthetic paint over one coat of red oxide primer duly grouted in PCC 1:3:6 of foundation, control wiring copper stranded PVC insulated FRLS cables & inter connections of suitable size/capacity of copper strips for switch gear connection from main bus bar, earth nbus strip of 25x3mm size for entire length of panel,suiytable size of MS gland with gland plate and aluminium lugs/thumbles for all incoming and outgoing cables etc, complete all as specified and as directed by Engr-in -charge including and accomodating the followings:
1
-
-
... More
(a) MCCB 4 pole 100Amps 25Ka-01 Nos(Incoming)
(b) MCCB 4 pole 63Amps 25Ka-03 Nos(Outgoing)
(c) MCB SPN 32Amps -04 Nos(Outgoing)
(d ) LED type three Phase indicator with controlling fuses for RYB -01 Set
(e) 3 phase multifucntioning energy meter (Next Gen)-01 Nos
-
-
-
... More
Notes for item No. 5 to 10:
(a) The Contractor shall submit drawings from the approved OEM for approval of the GE through the Engineer-in-charge
(b) The feeder pillar/panel shall include 2Nos. danger notice plates made of 1.6mm thick mild steel sheet, vitreous enamelled white, of size 250x200mm with letter, figures and conventional skull bones in signal red colour duly fixed with nuts, bolts and washers, etc. with voltage and danger indicated both in Hindi and English
(c) The feeder shall include electrolyitc aluminium bus bars as stipulated PVC coloured sleeves mounted on hygroscopic insulators duly colour coded and earth bar in 40x5mm GI strip and complete wiring including flush mounting rated CTs of size 96x96mm
(d) Excavation, earthwork in any type of soil, construction of PCC foundation for panel shall be deemed included in quoted rate. Foundation specifics shall be as per OEM of panel. The Contractor shall submit foundation desgn drawings to attain approal of he GE
(e) Foundation bed shall be in PCC 1:3:6 type C2 using 40mm graded stone aggregates with a depth of 15cm below ground level and 1.5m above ground level with stare and slot openings for I/C and O/G cables
-
-
-
... More
Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, screwed PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective item herein
-
-
-
... More
2 core 10 Sqmm
195
-
-
... More
4 core 10 Sqmm
540
-
-
... More
2 core 16 Sqmm
255
-
-
... More
4 core 25 Sqmm
175
-
-
... More
3.5 core 35 Sqmm
120
-
-
... More
3.5 core 50 Sqmm
165
-
-
... More
3.5 core 70 Sqmm
260
-
-
... More
3.5 core 95 Sqmm
140
-
-
... More
3.5 core 120 Sqmm
285
-
-
... More
S&F in repairs onload change over switch, 63A 4 Pole 240V 50Hz, AC-33 suitable for AC supply with side handle operation housed in CRCA sheet dust and vermin proof metal enclosure, stove enameled epoxy coated, polyester insulated including taking down of old unsv, complete all as specified and as directed
2
-
-
... More
S&F in repairs onload change over switch, 100A 4 Pole 240V 50Hz, AC-33 suitable for AC supply with side handle operation housed in CRCA sheet dust and vermin proof metal enclosure, stove enameled epoxy coated, polyester insulated including taking down of old unsv, complete all as specified and as directed
1
-
-
... More
S&F MCCB 4 Pole, 415V, adjustable thermal magnetic release type, Ics=100% Icu, conforming to IS/IEC:60947-2 including shutting down of electric supply, taking out old unserviceable MCCB from any location, position, etc. and disposing off complete all as specified and as directed of the following capacities:
-
-
-
... More
200Amps 36 KA
1
-
-
... More
100 Amps 36 KA
1
-
-
... More
63 Amps 25KA
2
-
-
... More
S&F outdoor type,weather proof, thermplastic polycarbonate, shock proof, rust proof pole mounting junction box, IP66/69 in accordance with IEC 60529, with 5 pole terminal suitable to terminate upto 10sqmm 4 core and 2 core cables with metric knockouts on side walls of size 205x255x112mm, etc. incuding takng down old unserviceable junction box and disposing off complete all as specified and as directed
7
-
-
... More
S&F copper strip of size 20x3mm with saddles and fixing screws, FRP insulators, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed /welded at each joint complete all as specified and as directed
25
-
-
... More
S&F GI strip of size 25x4mm with saddles and fixing screws, FRP insulators, etc. for roof conductors, down conductors and wall conductors above the ground, etc. brazed/welded at each joint complete all as specified and as directed
20
-
-
... More
Supplying, fixing / laying steel water tubing, 25mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables including taking out and disposing off old damaged tubing complete all as specified and as directed
35
-
-
... More
Supplying, fixing / laying steel water tubing, 40mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables including taking out and disposing off old damaged tubing complete all as specified and as directed
55
-
-
... More
Supplying, fixing / laying steel water tubing, 50mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables including taking out and disposing off old damaged tubing complete all as specified and as directed
40
-
-
... More
Supplying, fixing / laying steel water tubing, 80mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables including taking out and disposing off old damaged tubing complete all as specified and as directed
40
-
-
... More
&L for earthing using galvanised earth plate electrode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including copper strip of size 20x3mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
8
-
-
... More
&L for earthing using copper earthing strip with copper steel earth plate electrode 600x600x3.15mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including copper strip of size 20x3mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
10
-
-
... More
M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
6
-
-
... More
Notes for serial item No. 33 to 36: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included
(ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%