Military Engineer Services Tender

View complete overview of Mizoram MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Feb 2023
Closing Date10 Mar 2023
Tender Amount₹ 14,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes

24.4

-

-

... More
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed

3440

-

-

... More
M&L for dismantling and taking down old unserviceable junction boxes of any type /size from any location / position and disposing off including all necessary carting, etc. complete all as specified and as directed

10

-

-

... More
S&F thermoplastic cable junction boxes IP-65 protection class, of size 210x155x92mm, with metric knockout for cable entry, weather proof suitable for outdoor installation, including glands and with 4 terminal for terminating one incoming and outgoing UG cable of size 10/16sqmm 2/4 core fixed to electric poles any type by means of suitable MS clamps, nuts and bolts with 01No. MCB SP 20A 10kA (rate shall be included) inside the box complete all as specified and as directed

10

-

-

... More
Supplying, laying / fixing, testing and commissioning of electric cable, 1100V grade aluminium conductor XLPE insulated, armoured cables conforming to IS-7098 (Part-I)-1988, stranded, PVC bedded laid in trenches, passing through ducts, etc. fixed on poles, etc. including taking out old damaged cable and disposing off complete all as specified and as directed of the following sizes: Note: Excavation/earthwork, bricks, sand cushioning and GI pipe will be measured and paid separately under respective items herein

-

-

-

... More
3.5 core 25sqmm

50

-

-

... More
4 core 16sqmm

100

-

-

... More
4 core 10sqmm

50

-

-

... More
2 core 10sqmm

50

-

-

... More
2 core 6sqmm

100

-

-

... More
2 core 4sqmm

100

-

-

... More
M&L for taking down carefully post top lanterns of any capacity / any make after disconnecting electric connections and carrying out repairs by replacing worn out / burnt / damaged parts / components and refixing the same after carrying out necessary repairs to original place and re-connecting up complete all as specified and as directed Note: Replaced major parts / components will be measured under respective items hereunder and minor spares viz. glands, nuts, bolts, etc. shall be deemed to be included in quoted rate

35

-

-

... More
M&L for taking down carefully flood light / street light of any capacity / any make after disconnecting electric connections and carrying out repairs by replacing worn out / burnt / damaged parts / components and refixing the same after carrying out necessary repairs to original place and re-connecting up complete all as specified and as directed Note: Replaced major parts / components will be measured under respective items hereunder and minor spares viz. glands, nuts, bolts, etc. shall be deemed to be included in quoted rate

20

-

-

... More
S&F LED street light, 72W new generation energy saving, environmental friendly, long life, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP-66 protection and impact resistance of IK07 with 10kV built-in surge protection device with 72W LED lamp including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

7

-

-

... More
S&F LED street light, 70W new generation energy saving, environmental friendly, long life, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP-66 protection and impact resistance of IK07 with 10kV built-in surge protection device with 70W LED lamp including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

6

-

-

... More
S&F 150W LED flood light fitting, pressure die cast aluminium housing with heat resistant toughened glass, IP-66 protection luminaries with 150W LED lamp including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

2

-

-

... More
S&F 200W LED flood light fitting, pressure die cast aluminium housing with heat resistant toughened glass, IP-66 protection luminaries with 200W LED lamp including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

2

-

-

... More
S&F LED 100W flood light, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP-66, suitable for highlighting architectural facade and general purpose lighting with 100W LED lamp including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

2

-

-

... More
S&F LED 120W flood light, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP-66, suitable for highlighting architectural facade and general purpose lighting with 120W LED lamp including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

2

-

-

... More
S&F LED 300W flood light, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP-66, suitable for highlighting architectural facade and general purpose lighting with 300W LED lamp including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

2

-

-

... More
S&F 25W post-top lantern, opal light fitting, IP-65, new generation, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

4

-

-

... More
S&F 20W LED heritage pattern post top, ideal to light up parks, garden ways and heritage sites, IP-65 with rated LED 20W including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

4

-

-

... More
S&F neo LED street light 90W for garden ways and other City beautification applications with decorative steel bracket astehtically designed as per manufacturer including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

2

-

-

... More
S&F LED 10W light, pressure die cast powder coated housing with PC diffuser and efficient high output LED with IP-66 protection including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

4

-

-

... More
S&F radiant LED step light 7W for outdoor application with IP-65 protection including taking down old / unserviceable light and disposing off complete all as specified and as directed

4

-

-

... More
S&F moon (opal) 9W decorative gate light made up of high grade unbreakable polycarbonate material suitable for 9W LED bulb including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

6

-

-

... More
S&F LED 60W street light, new generation energy saving, environmental friendly, long life, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP-66 protection, impact resistance of IK07 with 1kV built-in surge protection device including taking down old / unserviceable fitting and disposing off complete all as specified and as directed

4

-

-

... More
M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in foundations, for fixing poles, etc. complete all as specified and as directed

0.75

-

-

... More
M&L in repairs for cross arms, bracings, supports clamps, and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat, one under coat and one finishing coat of good quality of aluminium paint all as specified and as directed

0.4

-

-

... More
S&F in repairs security light bracket with 40mm bore GI tubing, light grade, cut and bent to shape required, 1.5m long fixed with including bends, flat iron clamp made of FI 40x6mm, nuts, bolts, washers, etc. duly painted with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specfied and as directed

4

-

-

... More
Supplying, fixing steel water tubing, 40mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or floors for mounting of post top lanterns, cut to required length of 1.5m long (each) duly grouted in ground complete all as specified and as directed

10

-

-

... More
M&L for taking down AC 1.5/2TR capacity for required servicing, cleaning of cooling coil, air filters/plasma filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solutions, etc., checking serviceability of electrical / electronic parts viz. circuit relays, wiring kit, thermostat switches, knobs, remote control unit, fan, blower, etc. and ensuring the AC unit in satisfactory working conditions complete all as specified and as directed for the following type of AC units: Notes: (a) Spares / parts / components replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement including all allied works shall be deemed to be included in the unit rate quoted (b) Gas charging as required shall be deemed to be included in the quoted rate (c) Cost of taking down, loading / unloading, carting (to & fro) to workshop if required shall be deemed to be included in the quoted rate

-

-

-

... More
Window type AC units

5

-

-

... More
Spli type AC units

12

-

-

... More
S&F in repairs the following spare parts including necessary fittings as per sample and suitable for air conditioner 1.5/2T, split / window type units complete all as specified

-

-

-

... More
Thermostat switch with regulating knob

5

-

-

... More
Starting capacitor 80/100Mfd

6

-

-

... More
Blower motor 8Mfd capacitor

5

-

-

... More
Running capacitor 36Mfd

4

-

-

... More
Running capacitor 50Mfd

2

-

-

... More
Relay box / open type

2

-

-

... More
Selector switch with knob

4

-

-

... More
Overload protector relay

4

-

-

... More
Strainer / drier

3

-

-

... More
Front grill suitable as per existing pattern including fixing screw

2

-

-

... More
Air filter

4

-

-

... More
Remote control PCB

2

-

-

... More
Capillary charging

2

-

-

... More
MS stand for split AC

2

-

-

... More
Supply, installing, testing and commissioning of compressors of AC units, in any location / position including disconnecting electrical mains, remove the refrigerant and capture it in a storage cylinder, cutting line sets, removing the condenser coil and everything around the compressor, taking out the condenser unit, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally put the rest back together and balance charging of refrigerant gas F-22/R-134A (if required) including disposing of old unserviceable condensor unit complete all as specified and as directed of the following capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers

-

-

-

... More
1.5Ton

3

-

-

... More
2Ton

4

-

-

... More
S&F in repairs condensing coil assembly of air conditioner of any make, including necessary fittings viz. clamps, nuts, bolts, etc. and all required soldering, brazing, etc. complete all as specified and as directed

4

-

-

... More
S&F in repairs blower motor assembly of air conditioner of any make, as per existing including necessary fittings viz. clamps, nuts, bolts, etc. complete all as specified and as directed

4

-

-

... More
M&L for charging refrigerant gas F-22/R-134A in split type AC unit of capacity 1.52Ton including required staging / taking down of compressor units, etc. as required, detecting leakages, etc. stopping leakages by welding and testing on commissioning in satisfactory working conditions complete all as specified and as directed

5

-

-

... More
M&L for disconnecting from mains, for servicing refrigerators including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches, knobs, leakage of gas, etc. and making the deep freezer / refrigerator to satisfactory working conditions complete all as specified and as directed of the following capacities: Notes: (a) Spares / parts / components replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement including all allied works shall be deemed to be included in the unit rate quoted (b) Gas charging as required shall be deemed to be included in the quoted rate (c) Cost of lifting, loading / unloading, carting (to & fro) to workshop if required shall be deemed to be included in the quoted rate

-

-

-

... More
310litres

3

-

-

... More
230/285/286litres

2

-

-

... More
165/175/185litres

4

-

-

... More
Supply only the following spare parts as per sample and suitable for refrigerators including necessary fittings complete all as specified and as directed

-

-

-

... More
Strainer or drier round type

3

-

-

... More
Relay box type 1/6HP

4

-

-

... More
Switch for cabinet bulb

4

-

-

... More
Lamp screw type

3

-

-

... More
Door lock with duplicate keys

4

-

-

... More
Relay open type (over load cum relay)

3

-

-

... More
Overload protector

4

-

-

... More
Cooling coil door with locking spring

3

-

-

... More
Thermostat switch with regulating knob

4

-

-

... More
Ice tray

2

-

-

... More
Fan motor / evaporator

4

-

-

... More
Fan blade

3

-

-

... More
Chiller tray as per existing model

4

-

-

... More
Frost free timer

1

-

-

... More
Frost free cooling coil

2

-

-

... More
Capillary charging

2

-

-

... More
Thermal fuse

5

-

-

... More
S&F company made new sealed compressor units for refrigerators, including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed of the following capacities: Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers

-

-

-

... More
165 to 185litres

2

-

-

... More
310litres

2

-

-

... More
M&L for charging refrigerant gas F-22/R-134A in refrigerator units of any capacity and testing on commissioning in satisfactory working conditions complete all as specified and as directed

5

-

-

... More
M&L for disconnecting from mains and taking down for servicing water coolers including cleaning the cooling coil, air filters, condenser, compressors, fan motor, etc. with vacuum cleaner and cleaning solution, checking serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc. and making the water cooler to satisfactory working conditions complete all as specified and as directed of the following capacities: Notes: (a) Spares / parts / components replaced will be measured and paid separately under relevant items hereinafter and labour charges for replacement including all allied works shall be deemed to be included in the unit rate quoted (b) Gas charging as required shall be deemed to be included in the quoted rate (c) Cost of lifting, loading / unloading, carting (to & fro) to workshop if required shall be deemed to be included in the quoted rate

-

-

-

... More
150litres

5

-

-

... More
60/120litres

4

-

-

... More
40/80litres

5

-

-

... More
S&F company made new sealed compressor units for water coolers of capacity 60/120litres, including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas (if required) including disposing off old unserviceable compressor unit complete all as specified and as directed Notes: (i) Compressor units shall be from existing manufacturer / as approved by the GE (ii) Compressors shall be brought in sealed conditions (iii) Compressor shall bear a minimum guarantee of 5years and as given by manufacturers

2

-

-

... More
M&L for charging refrigerant gas F-22/R-134A in water cooler units of any capacity and testing on commissioning in satisfactory working conditions complete all as specified and as directed

2

-

-

... More
S&F in repairs blower motor assembly of water coolers of any make, as per existing including necessary fittings viz. clamps, nuts, bolts, etc. complete all as specified and as directed

4

-

-

... More
S&F in repairs condensing coil assembly of water coolers of any make, including necessary fittings viz. clamps, nuts, bolts, etc. and all required soldering, brazing, etc. complete all as specified and as directed

4

-

-

... More
Supply only the following spare parts as per sample and suitable for water coolers including necessary fittings complete all as specified and as directed

-

-

-

... More
Starting capacitor 60-80Mfd

4

-

-

... More
Running capacitor 25Mfd

4

-

-

... More
Relay box type 1022

3

-

-

... More
Thermostatic switch with regulating knob

4

-

-

... More
Push cock, self closing chromium plated 15mm bore including nut and washer, etc.

4

-

-

... More
PVC drain pipe 1m long including clamps

3

-

-

... More
Float valve of glass or gun metel, 15mm bore with ball

3

-

-

... More
Over load protector relay

4

-

-

... More
Running capacitor 36Mfd

4

-

-

... More
Capillary charging

4

-

-

... More
Pencil strainer

2

-

-

... More
M&L for earthing using GI earthing strip with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 25x4mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm medium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x 600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications and taking down old earthing complete all as specified and as directed

2

-

-

... More
Notes for serial item No. 105: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.