Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681553_1Tender No
8884/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
117.2
-
-
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
64.17
-
-
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
99
-
-
Excavating in post holes (or similar holes) each not exceeding 0.5cum, returning, filling in, getting out in soft / loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance not exceeding 50m complete all as specified and as directed
9
-
-
B/R WORKS
-
-
-
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed
3.18
-
-
M&L for hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, using broken stone or boulders complete all as specified and as directed
10.12
-
-
M&L for hand packing (any thickness) with broken stone or boulders at back of walls over arches, etc. and raising (or lowering) to the required level complete all as specified and as directed
19.42
-
-
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed at both ends, each screwed end to be fitted with washers and one hexagonal or square nut, 22.5 to 30cm in length, dia of neck & shank 11 to 15mm complete all as specified and as directed
24.6
-
-
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed
192
-
-
S&F bands, straps, hold fasts, wall ties, two way and three way straps, plate washers and similar articles of mild steel 25x5mm conforming to Fe-290 grade E-165 complete all as specified and as directed
49.68
-
-
S&F in position steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer, etc. using ERW or induction butt welded tubes / SHS conforming to IS-1161-2014 / IS-4923-1997 grade St-210 complete all as specified and as directed
705.55
-
-
S&F plates (plain or chequered) channels, square cut or notched (ordinay and counter sunk) forming holes, without any attachment of Fe 410W grade-E -250, quality 'B' complete all as specified and as directed
202.91
-
-
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
1752.49
-
-
M&L for mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
233.41
-
-
M&L for mild steel TMT bars 8 mm dia and ove upto and including 10mm dia in stirrups, spacers and binders, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
551.63
-
-
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces complete all as specified and as directed
85.98
-
-
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and as directed
12.6
-
-
M&L for formwork to sides and soffits of floor or roof beam, beam haunching, girder, lintels, cantilever, shelves including supports, etc. for rough finished flat surfaces of concrete complete all as specified and as directed
25.2
-
-
M&L for formwork to rough finished surfaces of flat concrete, chullah hoods, chajjas, troughs and similar items including edges for rough finished flat surfaces of concrete complete all as specified and as directed
8.79
-
-
M&L for walling of random rubble, coursed in retainning walls, abutments and similar works, regular coursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) with lime/sand stone and PCC (1:3:6) type C1 precast bond stone (in lieu of stone bond stone) set in cement mortar (1:4) complete all as specified and as directed Notes:
(i) Precast PCC bond stone shall be measured and paid separately under relevant item herein
(ii) RR masonry shall be measured after deducting volume of PCC bond stones
73.79
-
-
M&L for precast PCC bond stone of in PCC (1:3:6) type C1 using 20mm graded stone aggregates for retainning wall, abutment and similar works (set in cement mortar 1:4) including all neccessary formwork, etc. complete all as specified and as directed
2.74
-
-
M&L for raised pointing to random rubble, coursed masonry walls in CM (1:3) complete all as specified and as directed
7.42
-
-
M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregates as in foundation filling, mass concrete, etc. complete all as specified and as directed
29.95
-
-
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregates as in foundation filling, mass concrete, etc. complete all as specified and as directed
1.08
-
-
M&L for 100mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregates) as in sub-base for floors, etc. surface finished fair and even complete all as specified and as directed
73.5
-
-
M&L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in floors, plinth protection, pavings, etc. surface finished even and fair, laid in alternate bays/panels and joints filled with bituminous mix of 1 part bitumen and 3 part of sand complete all as specified and as directed
29.2
-
-
M&L for 25mm thick plain cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregates) in floors, levelling courses and similar works complete all as specified and as directed
127
-
-
M&L for plain cement concrete 1:2:4 (type B-2) using 40mm graded stone aggregate as in beds of drains, surface channels, etc. complete all as specified and as directed
0.72
-
-
M&L for extra in forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directed
Note: Inner girth shall only be measured
60
-
-
M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping including necessary formwork complete all as specified and as directed
1.29
-
-
M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles, mass concrete, etc. complete all as specified and as directed
17.28
-
-
M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in columns, posts, piers, pillars, struts, etc. complete all as specified and as directed
4.32
-
-
M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in beams, cantilevers, lintels, etc. over 1.5m long complete all as specified and as directed
0.89
-
-
M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in chajjas etc complete all as specified and as directed
0.55
-
-
M&L for precast autoclaved acrated concrete bricks (AAC) blocks masonry with 100mm to 150 mm thick with garde -I , AAC blocks of density 551 to 650kg/cum conforming to IS-2185 (Part-III) supoer structure above plinth level upto floor-V level with RCC bend at still level and lintel level with approved block laying polymer modified adhesive mortar , complete all as specified and directed.
Note: RCC bend and reinforcement shall be measured and paid separately.
23.07
-
-
M&L rendering 12mm thick, in cement mortar (1:6) on fair faces of walls / concrete surfaces, etc. finished even and fair without using extra cement complete all as specified and as directed
289.09
-
-
Supply only integral water proofing compound all as specified
10.95
-
-
S&F pressed steel frames made of 1.25mm thick MS sheet of profile 165x60mm for door and window frames with one or more rebates including hinges (100/50mm stainless steel), lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of aldrop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs, etc. complete all as specified and as directed
76.8
-
-
S&F steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast including suitable locking arrangements complete all as specified and as directed
3.24
-
-
S&F 2nd class hard wood 30mm thick plain, framed, paneled shutters (any number of panels), with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats complete all as specified and as directed
7.2
-
-
S&F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc and divided into squares, with plain, chamfered or rounded, mitred and rebated with sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., supplied and fitted to chowkats complete all as specified and as directed
7.2
-
-
S&F 30mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc and divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, sizes of members of shutters as specified in clause 8.24(b) of SSR Part-I, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., supplied and fitted to chowkats complete all as specified and as directed
17.28
-
-
S&F 3mm thick sheet glass ordinary quality and glazing with oil putting square not exceeding 0.5sqm in each pane including hacking out old glass complete all as specified and as directed
13.83
-
-
S&F in repairs 200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed
9
-
-
S&F in repairs 150mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed
36
-
-
S&F in repairs 150mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed
48
-
-
S&F 300mm aluminium anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed
3
-
-
M&L for preparation of masonry / concrete wall surfaces and applying two coats of oil bound distemper (tint as approved) over a coat of 1mm thick wall putty and including one coat of alkali resistant walll primer with all necessary staging, scaffolding, etc. as required complete all as specified and as directed.
136.24
-
-
M&L for preparing of old steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) complete all as specified and as directed
44.97
-
-
M&L for preparing of new wood / wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, tint as approved complete all as specified and as directed
81.9
-
-
M&L for preparing of new plastered or unplastered surfaces of walls and applying two coats of cement based paint (of approved tint) over a coat of wall primer complete all as specified and as directed
152
-
-
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.11sqm but not exceeding 0.18sqm each, 7 to 8mm thick of superior quality as in floors, etc. laid over 15mm thick screed bed in CM (1:4) (rate shall be included) set and jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed
123.16
-
-
M&L for glazed ceramic tiles, coloured, of size 300x200mm, 7 to 8mm thick, of superior quality as in vertical surfaces, skirting, dado, etc. laid over 10mm thick backing coat in CM (1:4) (rate shall be included) pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed
12
-
-
M&L machine cut and machine polished kota stone slab 20 to 25mm thick as in floors, in sizes as approved, set and jointed in neat cement slurry and pointed with cement and pigments to match the shade of slab including rubbing and polishing etc. laid over and including 20mm thick bedding layer in cement mortar 1:4 with cement slurry 4kg/sqm (cost shall be included) complete all as specified and as directed
77.04
-
-
M&L machine cut and machine polished kota stone slab 20 to 25mm thick as in vertical faces, dado, skirting, etc. in sizes as approved, set and jointed in neat cement slurry and pointed with cement and pigments to match the shade of slab including rubbing and polishing etc. laid over and including 10mm thick backing coat in cement mortar 1:3 (cost shall be included) complete all as specified and as directed
9.3
-
-
M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600x600mm with main runner 38x24mm and wall angle 24x24mm using 4mm thick high pressure non-asbestos fiber cement decorative board (E-Board Classic) in grid of GI system duly suspended from 4mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from roof with adjustment clips, providing positions for light fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detectors, etc., cnforming to IS 14862, the main runners duly secured to structural soffits by hanger @1220mm c/c (maximum) with the last hanger at the end of each main runner not interlocked between main runners @610mm c/c so as to form 600x600mm grid complete all as specified and as directed
61
-
-
S&F pre-painted galvalume aluminum zinc coating GI based corrugated / semi-corrugated steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering, cladding to walls, etc. fixed with self tapping screws complete all as specified and as directed
159.44
-
-
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering, cladding to walls, etc. fixed with self tapping screws complete all as specified and as directed
11.34
-
-
S&F PVC (SWR) pipes, 110mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, etc. complete all as specified and as directed
57
-
-
S&F PVC (SWR) pipes, 75mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, etc. complete all as specified and as directed
64.73
-
-
E/M WORKS
-
-
-
Dismantling , taking down and refixing of serviceable street light fittings of 45 to 90 Watt, complete all as specified and directed.
8
-
-
Dismantling concrete poles/steel tubular poles/struts of any size , complete all as specified and directed.
19
-
-
M&L for point wiring with 1.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories concealed in walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly complete all as specified and as directed for the following:
-
-
-
One light point controlled by one 5A one way switch
13
-
-
One ceiling fan / exhaust fan point controlled by one 5A one way switch
3
-
-
One switch socket outlet 3 pin 5A controlled by one switch on independent board
7
-
-
One switch socket outlet 3 pin 5A controlled by one switch on same board
3
-
-
M&L for point wiring with 2.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC casing caping not less than 20mm wide and accessories flush on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly for 3 pin 15A switch socket independent outlet complete all as specified and as directed
5
-
-
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
16
-
-
S&F switch piano flush modular type, single pole, ISI marked, one way 6A, 1 module, 230V complete all as specified and as directed
29
-
-
S&F switch piano flush modular type, single pole, ISI marked, one way 16A, 1 module, 230V complete all as specified and as directed
5
-
-
S&F socket outlet, 2/3 pin, 6A modular type, ISI marked, combined 2 module, 230V complete all as specified and as directed
5
-
-
S&F socket outlet, 2/3 pin, 6A modular type, ISI marked, combined 2 module, 230V complete all as specified and as directed
1
-
-
S&F socket combination outlet, 2/3 pin, 6A modular type, ISI marked, 2 module, 230V complete all as specified and as directed
5
-
-
S&F socket combination outlet, 2/3 pin, 16A modular type, ISI marked, 2 module, 230V complete all as specified and as directed
6
-
-
S&F electronic fan regulator, modular type, stepped type (8 steps), 100W, 230V, 2 module, ISI marked duly connected up complete all as specified and as directed
3
-
-
S&F in repairs modular white cover plate of 3 module with frame ISI marked complete all as specified and as directed.
17
-
-
S&F in repairs modular white cover plate of 6 module with frame ISI marked complete all as specified and as directed.
3
-
-
S&F modular flush box with cover plate and frame of 3 module, white, ISI marked complete all as specified and as directed.
17
-
-
S&F modular flush box with cover plate and frame of 6 module, white, ISI marked complete all as specified and as directed.
3
-
-
S&F LED tube light fitting of 20 Watt , extruded aluminium housing enhances saftey , high quality PC diffuser, easy to install efficacy 110/125 lumen/ watt, complete all as specified and as directed
13
-
-
S&F BLDC ceiling fan 1200mm sweep, 230V, minimum air delivery 210CFM with service value 6.00 BEE 5 star rated, with blades, down rods and accessories and connecting up, complete all as specified and as directed
3
-
-
S&F sheet metal enclosures for 8 way MCB DB, 240V, SPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down of old enclosure and disposing off complete all as specified and as directed
2
-
-
S&F sheet metal enclosures for 4 way MCB DB, 415V, TPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down of old enclosure and disposing off complete all as specified and as directed
1
-
-
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 4sqmm and 1 run of 4sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit , heavy duty, ISI marked surface on wall/ceiling/roof, etc. with all required accessories complete all as specified and as directed
41
-
-
S&F 3 core flexible aluminium cable 4 sqmm from cable junction box to street light fitting with and including ERW steel conduit of 20mm dia with clamps, nuts, bolts etc , complete all as specified and directed.
115
-
-
S&F MCB SP, 240V, 5 to 32A, 10kA, 50Hz, C curve complete all as specified and as directed
10
-
-
S&F MCB SPN, 240V,32A, 10kA, 50Hz, C curve complete all as specified and as directed
2
-
-
S&F MCB isolator TPN, 415V, 63A, 10kA, 50Hz, B curve complete all as specified and as directed
1
-
-
S&F MCB SPN, 240V, 6 to 32A, 10kA, 50Hz, C curve complete all as specified and as directed
19
-
-
Supply, fixing, commissioning and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductors, 1100V grade 2 core 10 Sqmm laid in trenches/fixed to wall/under road/drawn through pipes etc. with copper cable glands and copper thimbles complete all as specified and as directed
Note: Excavation and earthwork will be measured and paid under respective items herein
256
-
-
Supply, fixing, commissioning and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductors, 1100V grade 4 core 10 Sqmm laid in trenches/fixed to wall/under road/drawn through pipes etc. with copper cable glands and copper thimbles complete all as specified and as directed
Note: Excavation and earthwork will be measured and paid under respective items herein
320
-
-
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed
Note: Only punned thickness of sand shall be considered for measurement purposes
24.3
-
-
Supply and laying burnt bricks of sub-class 'B' designation 75 of size 230x115x75mm laid in trenches for cable protection complete all as specified and as directed
3528
-
-
S&F steel water tubing, light grade, 40mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for cable protection, etc. complete all as specified and as directed
73
-
-
S&F hot dipped GI octagonal pole of 5 mtrs long with single arm, complete arrangment suitable for for mounting LED street light fitting, with bottom dia 130mm, top dia 70mm with 3mm sheet thickness and foundation nut bolts inlcuding necessary earthwork excavation, PCC,RCC (1:1.5:3) as per OEM drawing, complete all as specified and directed.
19
-
-
S&F new generation, energy saving and environmental friendly long life LED street light 45 Watt, made up of pressure die cast aluminium housing, toughened glass with high power LED as lightening source and lens embedded PC cover having top opening seperate driver compartment with IP 66 protection and impact resistant of IK07 with 10KV buit in surge protection device including taking down , complete all as specified and directed.
12
-
-
M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed
6
-
-
Notes for serial item No. 186: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included
(ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%