Military Engineer Services Tender

View complete overview of Mizoram MES Tender

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date16 Jul 2024
Closing Date5 Sep 2024
Tender Amount₹ 31,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed

12

-

-

... More
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed

27.8

-

-

... More
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed

47.8

-

-

... More
Excavating in post holes (or similar holes) each not exceeding 0.5cum, returning, filling in, getting out in soft / loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance not exceeding 50m complete all as specified and as directed

40

-

-

... More
M&L for hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, using broken stone or boulders complete all as specified and as directed

9.3

-

-

... More
M&L for hand packing (any thickness) with broken stone or boulders at back of walls over arches, etc. and raising (or lowering) to the required level complete all as specified and as directed

10

-

-

... More
B/R WORKS

-

-

-

... More
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed

3.75

-

-

... More
Dismantling of plain or corrugated steel sheeting, any gauge or any thickness in roof covering /wall cladding complete all as specified and as directed

168

-

-

... More
Dismantling mild steel work or wraught iron of any description and in any position complete all as specified and as directed

1.6

-

-

... More
Dismantling of timber scantling 40sqcm and over in section, in any position in unframed works complete all as specified and as directed

3.2

-

-

... More
Dismantling wall and ceiling boards (fibre, pulb, insulation, etc.) or insulation boards slabs/blankets of any thickness including cover fillets complete all as specified and as directed

231

-

-

... More
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed

2.3

-

-

... More
Taking down cement or cement/lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed

52.5

-

-

... More
Taking down wooden shutters of size not exceeding 1.0sqm and disposing off complete all as specified and directed

10

-

-

... More
Taking down wooden shutters of size exceeding 1.0sqm but not exceeding 2.0sqm and disposing off complete all as specified and directed

6

-

-

... More
Taking down chowkats or frames not exceeding 1.5sqm each with shutters (without taking off shutters from the frame), disposing off and making good the disturbed areas, portions and surfaces

5

-

-

... More
Taking down chowkats or frames exceeding 1.5sqm but not exceeding 4.0sqm each with shutters (without taking off shutters from the frame), disposing off and making good the disturbed areas, portions and surfaces

3

-

-

... More
Cutting into existing manholes for connecting new drain pipes, 150mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed

1

-

-

... More
M&L for taking down wooden shutters of any description not exceeding 2sqm each from steel / wooden frame and refixing after adjusting and easing out and refixing builder's hardware, mongeries, etc. complete all as specified and as directed

2

-

-

... More
M&L for dismantling plain steel sheet cladding on walls and refixing same after repairs complete all as specified and as directed

108.76

-

-

... More
S&F in position mild steel sheet 1.0mm thick, eaves gutters, galvanised class 3, half round, 150mm dia with rounded edges complete all as specified and as directed

22

-

-

... More
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed at both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm in length, dia of neck & shank 10mm complete all as specified and as directed

11.4

-

-

... More
S&F bands, straps, hold fasts, wall ties, two way and three way straps, plate washers and similar articles of mild steel 25x5mm conforming to Fe-290 grade E-165 complete all as specified and as directed

7.5

-

-

... More
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed

160

-

-

... More
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing conforming to Fe 410W grade-E -250, quality 'A' complete all as specified and as directed

120.5

-

-

... More
S&F rolled mild steel in stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. conforming to Fe-410-W grade E-250 quality-'A' complete all as specified and as directed

211

-

-

... More
S&F rolled mild steel angle iron posts & struts in fencing including cutting top to shape, drilling holes, notching for wire, flat iron fillets (for securing wire mesh) including all necessary drilling bolts or rivetting & similar works of Fe-410-0 or Fe-310-0 grade E-165 for securing chain link fencing, etc. complete all as specified and as directed

552

-

-

... More
Supply only chain link MS galvanised fencing, any size or type complete all as specified and as directed Note: Weight of chain link shall be ascertained by a BOO ordered by the GE

555

-

-

... More
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provisioning of binding wire complete all as specified and as directed

236

-

-

... More
Supply only mild steel conforming to Fe-410W grade E-250 quality-A, round bars 10mm dia, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in tie rods to chain link fencing complete all as specified and as directed

259

-

-

... More
M&L for mild steel TMT bars 10mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed

90

-

-

... More
M&L for formwork to soffits of suspended slabs, such as roof slab, floor slab, landings and similar works not exceeding 200mm thick for rough finished flat surfaces of concrete complete all as specified and as directed

5.9

-

-

... More
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed

5.2

-

-

... More
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed

56.8

-

-

... More
M&L for walling of random rubble, coursed in retainning walls, abutments and similar works, regular coursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) with lime/sand stone and PCC (1:3:6) type C1 precast bond stone (in lieu of stone bond stone) set in cement mortar (1:4) complete all as specified and as directed Notes: (i) Precast PCC bond stone shall be measured and paid separately under relevant item herein (ii) RR masonry shall be measured after deducting volume of PCC bond stones

36

-

-

... More
M&L for precast PCC bond stone of in PCC (1:3:6) type C1 using 20mm graded stone aggregates for retainning wall, abutment and similar works (set in cement mortar 1:4) including all neccessary formwork, etc. complete all as specified and as directed

2.5

-

-

... More
M&L for raised pointing to random rubble, coursed masonry walls in CM (1:3) complete all as specified and as directed

3.9

-

-

... More
M&L for 25mm thick plain cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregates) in floors, levelling courses and similar works complete all as specified and as directed

96

-

-

... More
M&L for 40mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregates) as in su-bases, flooring, paving, etc. surfaces finished even and fair complete all as specified and as directed

93

-

-

... More
M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping including necessary formwork complete all as specified and as directed

0.55

-

-

... More
M&L for pre-cast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in landings, cover slabs for manholes, chullah hoods, chajjas, water troughs, shelves and similar articles, with plain faces, set in CM 1:4 complete all as specified and as directed

0.7

-

-

... More
M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping, benching inside manholes (1/2 or 3/4 sections), rounded or chamfered at edges including all necessary formwork complete all as specified and as directed

0.3

-

-

... More
M&L for plain cement concrete 1:2:4 (type B-2) using 40mm graded stone aggregate as in beds of drains, surface channels, etc. complete all as specified and as directed

0.3

-

-

... More
M&L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in floors, plinth protection, pavings, etc. surface finished even and fair, laid in alternate bays/panels and joints filled with bituminous mix of 1 part bitumen and 3 part of sand complete all as specified and as directed

18

-

-

... More
M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in foundation filling, mass concrete, complete all as specified and as directed

10.8

-

-

... More
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregates as in foundation filling, mass concrete, etc. complete all as specified and as directed

8

-

-

... More
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed

5

-

-

... More
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directed Note: Inner girth shall only be measured

27

-

-

... More
M&L rendering 15mm thick, in cement mortar (1:4) on walls / concrete surfaces, etc. in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished even and smooth without using extra cement complete all as specified and as directed Note: WPC will be measured and paid separately under respective item herein

22.5

-

-

... More
M&L rendering 15mm thick, in cement mortar (1:4) on walls / concrete surfaces, etc. finished even and fair without using extra cement complete all as specified and as directed

82.5

-

-

... More
M&L rendering 15mm thick, in cement mortar (1:6) on walls / concrete surfaces, etc. finished even and fair without using extra cement complete all as specified and as directed

30

-

-

... More
M&L rendering 10mm thick, in cement mortar (1:4) on walls / concrete surfaces, etc. finished even and fair without using extra cement complete all as specified and as directed

8.9

-

-

... More
Supply only integral water proofing compound all as specified

1.7

-

-

... More
M&L for 2nd class hardwood fillets square, rectangular or triangular in section clean sawn secured with nails exceeding 6sqcm and not exceeding 13sqcm in section complete all as specified and as directed

160

-

-

... More
M&L for 2nd class hard wood timber scantling clean sawn in section, timber framed & fixed complete all as specified and as directed

3.3

-

-

... More
S&F 30mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc and divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, sizes of members of shutters as specified in clause 8.24(b) of SSR Part-I, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., supplied and fitted to chowkats complete all as specified and as directed

10.8

-

-

... More
S&F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc and divided into squares, with plain, chamfered or rounded, mitred and rebated with sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., supplied and fitted to chowkats complete all as specified and as directed

10.8

-

-

... More
S&F 4mm thick asbestos cement plain building boards in ceilings, soffits, etc. fixed to timber framework with screws and applying two coats of white wash complete all as specified and as directed

231.4

-

-

... More
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed

8

-

-

... More
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5sqm in each pane complete all as specified and as directed

1.3

-

-

... More
S&F 150mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed

36

-

-

... More
S&F 150mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed

20

-

-

... More
S&F 200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed

14

-

-

... More
S&F 300mm aluminium anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed

3

-

-

... More
S&F 300mm, brass, ordinary rat tail rod pattern door springs including roller and roller plate complete all as specified and as directed

6

-

-

... More
S&F in repairs 20mm dia fancy type chromium coated (tint as approved) MS curtain / drapery rods, etc. of rod wall thickness 1mm (min), including pair of CP MS brackets, holders with funnel at ends complete all as specified and as directed

24

-

-

... More
M&L for preparation of masonry / concrete wall surfaces and applying two coats of oil bound distemper (tint as approved) over and including one coat of alkali resistant walll primer and chalk whitening with all necessary staging, scaffolding, etc. as required complete all as specified and as directed

170

-

-

... More
M&L for preparation of old decorated plastered masonry / concrete wall surfaces and applying one coat of oil bound distemper (tint as approved) with all necessary staging, scaffolding, etc. as required complete all as specified and as directed

123

-

-

... More
M&L preparation of old decorated plastered / unplastered ceiling / soffit surfaces including cornices, etc. and applying two coats of white wash complete all as specified and as directed

61.8

-

-

... More
M&L for preparing of new plastered or unplastered surfaces of walls and applying two coats of cement based paint over a coat of wall primer complete all as specified and as directed

57.6

-

-

... More
M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed

62.8

-

-

... More
M&L for preparing of new steel / metal surfaces of any description not exceeding 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed

50

-

-

... More
M&L for preparing of old steel / metal surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint (tint as approved) complete all as specified and as directed

108.8

-

-

... More
M&L for preparation of new wood or wood based surfaces of any description not exceeding 10cm in width or girth and applying two coats of synthetic enamel paint (of approved tint) over one coat of pink primer complete all as specified as as directed

36.6

-

-

... More
M&L for preparing of old wood / wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint, tint as approved complete all as specified and as directed

47.7

-

-

... More
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.11sqm but not exceeding 0.18sqm each, 7 to 8mm thick of superior quality as in floors, etc. laid over 15mm thick screed bed in CM (1:6) (rate shall be included) set and jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed

96

-

-

... More
M&L for glazed ceramic tiles, coloured, of size 300x200mm, 6 to 7mm thick, of superior quality as in vertical surfaces, skirting, dado, etc. laid over 10mm thick backing coat in CM (1:4) (rate shall be included) pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed

9

-

-

... More
M&L for reflective type chequered cement concrete tiles 250x250x25mm thick, set, jointed and pointed in neat grey cement slurry mixed with no pigment as in floors laid over and including 15mm screed bed in CM 1:4 (rate shall be included) complete all as specified and as directed

93

-

-

... More
S&F pre-painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed

162

-

-

... More
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed

6.6

-

-

... More
S&F in repairs 600x450mm full sized bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed

6

-

-

... More
S&F PVC (SWR) pipes, 110mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, etc. complete all as specified and as directed

12

-

-

... More
S&F PVC (SWR) pipes, 75mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, etc. complete all as specified and as directed

3.6

-

-

... More
S&F PVC (SWR) pipes, 75mm bore, single socketed in any length as in weel holes, etc. complete all as specified and as directed

33

-

-

... More
S&F 75mm dia PVC (SWR) vent cowl complete all as specified and as directed

2

-

-

... More
E/M WORKS

-

-

-

... More
Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed

83

-

-

... More
Taking down house service bracket of any size / shape from any location/position and disposing off complete all as specified and as directed

1

-

-

... More
Taking down main switches, sheet metal enclosures, DBs by disconnecting and blanking supply mains from any location/position and disposing off complete all as specified and as directed

3

-

-

... More
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic PVC casing capping not less than 25mm wide and accessories flush on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for sinking for box and making good to the surface to match the existing and terminal boxes complete all as specified and as directed for the following:

-

-

-

... More
One light point controlled by one 5A one way switch

36

-

-

... More
One ceiling fan / exhaust fan point controlled by one 5A one way switch

12

-

-

... More
One switch socket outlet 3 pin 5A controlled by one switch on independent board

17

-

-

... More
One switch socket outlet 3 pin 5A controlled by one switch on same board

6

-

-

... More
M&L for point wiring with 2.5sqmm, two single core, FRLS PVC insulated, ISI-694 marked, unsheathed cable 1100V grade with multi-stranded copper conductor, drawn through and including non-metallic PVC casing capping not less than 20mm wide and accessories surface on walls, ceiling etc. and including provision of 2.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including surface box, etc. complete all as specified and as directed for one switch socket combination outlet 3 pin 15A multipurpose complete all as specified and as directed

12

-

-

... More
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed

32

-

-

... More
S&F switch piano flush modular type, single pole, ISI marked, one way 6A, 1 module, 230V complete all as specified and as directed

71

-

-

... More
S&F switch piano flush modular type, single pole, ISI marked, one way 16A, 1 module, 230V complete all as specified and as directed

12

-

-

... More
S&F socket outlet, 2/3 pin, 6A modular type, ISI marked, combined 2 module, 230V complete all as specified and as directed

23

-

-

... More
S&F socket combination outlet, 6 pin, 16A modular type, ISI marked, 3 module, 230V complete all as specified and as directed

12

-

-

... More
S&F electronic fan regulator, modular type, stepped type (8 steps), 100W, 230V, 2 module, ISI marked duly connected up complete all as specified and as directed

6

-

-

... More
S&F in repairs PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder with back plate 240V complete all as specified and as directed

6

-

-

... More
S&F in repairs modular metal flush box with white cover plate with frame ISI marked complete all as specified and as directed suitable of the following modules:

-

-

-

... More
3 modules

29

-

-

... More
4 modules

1

-

-

... More
6 modules

13

-

-

... More
8 modules

1

-

-

... More
S&F modular 1 module blank plate complete all as specified and as directed

4

-

-

... More
S&F in repairs decorative bracket flush type, PVC or polycarbonate suitable for LED bulb / lamp of approved design and pattern complete all as specified and as directed

6

-

-

... More
S&F in repairs 10W, white light, LED lamp suitable for bracket fittings complete all as specified and as directed

12

-

-

... More
S&F LED tube light fitting 1x20W, 220V, AC, decorative box type, with suitable driver, holder including 20W LED tube, all accessories prewired and connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to fitting and taking down and disposing off old fitting complete all as specified and as directed

16

-

-

... More
S&F LED bulk head 10W with pressure die cast aluminium housing high efficient LEDs and enclosed with milky diffuser IP 66 protection, input voltage 90-300V, PF 0.95, CRI 70, L 80 stranded luminaries with efficiency 100 lumen/Watt, with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable and taking down and disposing off old fitting complete all as specified and as directed

4

-

-

... More
S&F building security light, LED luminaire 20W IP 66 with LED lamp, driver, etc. with all accessories pre-wired and connecting with 3 core flexible copper conductor cable drawn through PVC conduit of size 20mm and taking down and disposing off old fitting complete all as specified and as directed

4

-

-

... More
S&F ceiling fan 1200mm sweep, 230V, minimum air delivery 210CFM with service value 6.00 BEE 5 star rated, with blades, down rods and accessories and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to fan and taking down old unserviceable ceiling fan, any sweep from any location/position and depositing in MES storeyard (cost of loading, unloading, carting to MES store as required shall be included in quoted rate) complete all as specified and as directed

6

-

-

... More
S&F heavy duty, sturdy Engineering plastic body with PVC blades, legs, ISI marked energy efficient, 230V, 50Hz, 900RPM, exhaust fan, 200mm sweep with louvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts and taking down old / unserviceable fan from any location / position and disposing off complete all as specified and as directed

6

-

-

... More
S&F sheet metal enclosures for 8 way MCB DB, 240V, SPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces complete all as specified and as directed

2

-

-

... More
S&F sheet metal enclosures for 4 way MCB DB, 240V, TPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces complete all as specified and as directed

1

-

-

... More
Taking down old unserviceable submain wiring of any type, any size, from any location or position and disposing off including making good the disturbed surfaces, etc. complete all as specified and as directed

65

-

-

... More
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 6sqmm and 1 run of 6sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 20mm wide, heavy duty, ISI marked concealed in wall/ceiling/roof, etc. with all required accessories complete all as specified and as directed Notes: (i) 2 runs of 6sqmm main cable, 1 run of earth conductors and 1 run of PVC conduit shall be measured as one length (ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of casing as per requirement at site

65

-

-

... More
S&F MCB SP, 240V, 6 to 32A, 10kA, 50Hz, C curve complete all as specified and as directed

20

-

-

... More
S&F MCB SPN, 240V, 6 to 32A, 10kA, 50Hz, C curve complete all as specified and as directed

4

-

-

... More
S&F MCB TPN, 415V, 63A, 4P 10kA, 50Hz, C curve complete all as specified and as directed

1

-

-

... More
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes

2.8

-

-

... More
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed

280

-

-

... More
S&F in repairs steel water tubing, light grade, 40mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for cable protection, etc. complete all as specified and as directed

12

-

-

... More
Supply, laying, jointing, connecting and testing 4 core 16sqmm XLPE insulated PVC sheathed cable 1100V grade, screwed PVC bedded, armoured electric power cable, conforming to IS: 7098 (Part-I), heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed Note: Excavation and earthwork will be measured and paid separately under respective item herein

45

-

-

... More
M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed

2

-

-

... More
Notes for serial item No. 131: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.