Military Engineer Services Tender

View past bidders for Meghalaya MES Tender

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date1 Apr 2025
Closing Soon29 Apr 2025
Tender Amount₹ 23,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for Virified Ceramic tiles Light shade 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in skirting, dado and risers to steps, etc over and including 10mm thick rendering in CM 1:3 set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing surface complete all as specified and directed.

25

-

-

... More
Taking down chowkats or frames exc 1.50 sqm but not exc 4.00 sqm each with shutters (without taking off shutters from the frame),complete all as specified and directed.

4

-

-

... More
Supply and fix anodised powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.

30

-

-

... More
Supply & fix powder coated (minimum thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section weighing 0.75 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading, lock, screws etc, complete all as specified and as directed.

9.6

-

-

... More
Supply & fixing sheet glass ordinary quality 5.50mm thick glazing in square/ rectangle n exc 0.50 sqm each pane with oil putty or aluminium beads fixed to steel etc, complete all as specified and as directed.

8

-

-

... More
Supply and fixing aluminium anodised (powder coated) Three track sliding window frame with shutters with ( 2 nos glazed and one wire gauzed shutter)including all necessary jointing cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete and glazing with and including 4 mm thick sheet glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc including aluminium grill of thickness 5mm and opening not exceeding 75mmx75mm complete with the following section of frame and shutter:- (A) Sections for shutter (i) 'H' section 39 x 20 x 1.20 mm thick (ii) 'Interlock' section 39 x 20 x 1.20 mm thick (iii) 'Edge & Bottom' section 41 x 20 x 1.20 mm thick (B) Section for frame (i) Top & Sides 92 X 29.50X 1.20mm thick (ii) Bottom 92 X 29.70 X 1.20mm thick complete all as specified and directed .

20

-

-

... More
S & F in repair 20mm dia mild steel chromium plated tubular decorative curtain rod complete all as specified and directed.

30

-

-

... More
S & F in repair decorative brackets suitable for curtain rod of 20mm dia complete all as specified and directed.

20

-

-

... More
M&L for Green Marble 16 to 18mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble over and including 15mm thick screed bed/bedding layer in CM 1:4 complete all as specified and directed.

4

-

-

... More
Material and labour for 15 mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.

60

-

-

... More
Material and labour for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces of walls, chajja, fins, facia etc any height mixed with water proofing compound @ 200 ml per 500 kg of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified and directed. Note :- (a) Water proofing compound shall be mix with 2nd layer only measured and paid separately under relevant item. (b) Cost of scaffolding of any height shall be included in this item. (c) Rendering will be done in two layers. 1st layer will be 10 mm thick and 2nd layer will be 5 mm thick. .

100

-

-

... More
Supply only Liquid water proofing compound complete all as specified and directed.

1

-

-

... More
Material and labour for 5 mm thick rendering in cement mortar (1:3) on concrete surfaces as in ceiling/chajja finished even and smooth without using extra cement complete all as specified and directed.

30

-

-

... More
M&L for preparation of new plastered surfaces and applying two coats of oil emulsion distemper (any colour/tint) over a coat of primer and 1 mm thick wall care putty on ceiling surfaces including rubbing with emmery paper to make wall surface smooth and even, complete all as specified and directed.

30

-

-

... More
M&L for preparation of new plastered surfaces and applying two coats of oil emulsion distemper (any colour/tint) over a coat of primer and 1 mm thick wall care putty on wall surfaces including rubbing with emery paper to make wall surface smooth and even complete all as specified and directed.

60

-

-

... More
M & L for complete removal of existing finishes and treating with two coats of oil emulsion distemper (any colour/tint) over a coat of primer and 1 mm thick wall care putty including rubbing with emery paper to make wall surface smooth and even complete all as directed and specified.

408

-

-

... More
Material & Labour for preparation of new plastered surface of wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.

100

-

-

... More
Material & Labour for preparation of old plastered surface of wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and as directed.

252

-

-

... More
M & L for complete removal of existing finishes and treating with two coats of oil emulsion distemper (any colour/tint) over a coat of primer and 1 mm thick wall care putty including rubbing with emery paper to make ceiling surface smooth and even complete all as specified and directed.

74

-

-

... More
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for etc complete all as specified and directed.

13.42

-

-

... More
M&L for 25mm thick PCC 1:2:4 Type B-1 ( using 20 mm graded crushed stone aggregate) as in sub base of floor complete all as specified and directed.

310

-

-

... More
M&L for 75 mm thick cement concrete 1:3:6 type C1 (using 20 mm graded aggregate) as in plinth protection finished fair and even with using extra cement complete all as specified and directed.

75

-

-

... More
Material and labour for taking down of existing roof treatment from roof and terrace, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust etc and applying roof treatment with the following steps and specifications:- a) Applying cement slurry over concrete surfaces @3kg/sqm. b) Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound @ 3% by weight of cement or @ 200ml per 50 Kg of cement or as per manufacturer's instruction on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof (levelling course). c) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @0.25 litres per sqm conforming to IS : 3384-1986. d) Applying evenly one coat of blown hot bitumen of grade 85/25@ 1.20Kg square metre on primed surfaces. e) A layer of APP based polymeric membrane, 3mm thick (minimum), weighing 3.5 kg/m2 reinforced with polyster non woven fabric (weighing not less than 160gms/Sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. f) Applying evenly one coat of aluminium paint @ 0.10litre per square metre over the APP based polymeric membrane.

150

-

-

... More
Material and labour for complete/Partial removal of loose/cracked concrete including cutting of reinforcement at Single/Double/Triple storey if required from RCC roof projection, chajja, fins, facia etc and applying bonding agent as per manufacture instruction and making good with RCC (1:1.5:3) type A0 (using 12.5 mm graded aggregate) in any slab and in any position finished the surface even and smooth without using extra cement including necessary formwork and welding/binding of reinforcement if required complete as directed by Engineer in charge. Note:- (1) reinforcement will be measured and paid seperately under respective items, (2) Rate shall be inclusive of bonding agent; make of bonding agent: Fosroc nitobond EP, Sika hibond, Pidilite 301 pidicrete URP. (3) The rate shall be inclusive of Scaffolding if required.

0.75

-

-

... More
M&L for Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.

45

-

-

... More
M&L for Providing and fixing false ceiling of designer tile ivory/white painted (high pressure steam cured ) of 4mm thick (as per IS: 14862) of size 595x595mm and any one of the design (cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel section (galvanized @120gms both side inclusive and black painted groove on all T webs)consisting of main T runner with suitably spaced joints to get required length and 15x32mm made of 0.3mm thick sheet spaced at 1200mm c/c and cross T of size 15x32mm made of 0.3mm sheet 1200mm long spaecd between main T at 600mm c/c to form a grid of 1200x600mm and secondary cross T of length 600mm and size 15x32mm made of 0.3mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.Main T runners to be suspended from trusses/ceilings using suitable suspension arrangement as per manufacturers instructions/literature. GI adjustable wire of 4mm dia with galvanized butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T section of 4mm dia GI wire shall be pre-painted with polyster paint and black painted groove at centre of size 4mm depth and 4.5mm width, including taking down old false ceiling board of any description alongwith rails and connecting items all complete at all heights as per direction of Engr-in-charge.

202

-

-

... More
Cutting opening in cement concrete/brick/block wall (any descript-ion) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc. complete all as specified and directed.

4

-

-

... More
M & L for RCC( Nominal Mix) Type B-1(1:2:4) (using 20mm aggregate) in beams, cantilevers,lintels, columns pillars,piers, posts, struts,chullah hoods, stair case,arches, domes, vaults,shell roofs, arch ribs,folded plates, slabs,balconies, canopies, deckslabs etc. or in similar articles etc complete all as specified and directed.

1

-

-

... More
M&L for RCC( Nominal Mix) Type B-1(1:2:4) (using 20mm aggregate) as in slab, chajjas and similar work complete all as specified and directed.

0.72

-

-

... More
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.

100

-

-

... More
S&F TMT bars 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.

50

-

-

... More
Use and waste of formwork to sides and soffit of beams, lintels, cantilevers, shelves etc for rough finished surface ,complete all as specified and directed.

12

-

-

... More
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.

12

-

-

... More
Material and labour for Pre-cast cement concrete block masonry Type C1 (1:3:6) (using 20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6) complete all as specified and directed.

2

-

-

... More
Dismantling CGI corrugated or semi corrugated sheets in wall cladding or roof coverings and hanger doors including ridges and make good for earthing strips after fixing of sheets complete all as specified and directed.

320

-

-

... More
S&F Pre- painted galvalume aluminium zinc coating PPGL based corrugated/Trapezoidal steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.

288

-

-

... More
S&F Pre- painted galvalume aluminum zinc coating PPGL based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, eaves board, fixed with self tapping screws complete all as specified and directed.

32

-

-

... More
Taking down carefully old unsv copper/aluminium point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. to be measured separately) and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as directed by the Engr-in-Charge.

90

-

-

... More
Taking down carefully MCB DBs SP/TP by unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed.

2

-

-

... More
Material and labour for point wiring for the followings with 1.5 sqmm single core, nominal cross sectional area PVC FRLSH insulated unsheathed, multistranded copper conductor drawn through concealed Conduit wiring including necessary accessories like bends, tees, PVC square and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLSH insulated unsheathed multi stranded copper conductor cable as earth conitinuity (green in colour) connected to common earth dolly including sunken type pressed steel terminal boxes of suitable sizes with plastic laminated white/coloured top sheet cover 3 mm thick complete all as specified and directed as below :- Note :- Rate for Cutting, chieseling and making good the existing surface for complete wiring is deemed to be included in quoted rate all as specified & directed by Engr-in-Charge.

-

-

-

... More
(a) One light/fan point controlled by one,one way switch.

61

-

-

... More
(b) One 3 Pin 5 Amps socket out let point on independent board.

16

-

-

... More
(c) One 3 Pin 5 Amps socket out let point on same board alongwith other suitable switches.

4

-

-

... More
All as per item No 43 here-in-before but using 2.5 sqmm PVC FRLSH insulated copper condutor wire for connecting 15A socket on independent board.

9

-

-

... More
Supply and fixing in repair switch piano flush type 240 Volts 5 Amps, SP, one way with white colour complete all as specifed and directed.

65

-

-

... More
Supply and fixing in repair switch socket outlet combination 3 Pin,5 Amps, 240 volts flush type (non shuttered) with white colour complete all as specified/ directed.

16

-

-

... More
Supply & fixing in repair socket 3 pin 5 Amps 240 Volts flush type (non shuttered) with white colour complete all as specified / directed.

4

-

-

... More
Supply and fixing in repair switch socket out let combination multipurpose 3 pin, 5/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) with white colour complete all as specified and directed.

9

-

-

... More
Supply and fixing in repair ceiling rose surface 3Phase/PVC/Polycarbonate, isolated body complete all as specified and directed.

36

-

-

... More
Supply & fixing ceiling fan regulator electronic, deluxe,rotary, step type, 120/280 V.

6

-

-

... More
Supply and fix in repair of MCB TPN DB 4 way 415 Volt, Busbar Capacity of 200 Amps double door,IP 43 protection,Glazed door, isolated neutral bar,insulated bus bar assembly,mechanical strength of IK09 including taking down old unserviceable MCB complete all as specified and directed.

1

-

-

... More
Supply and fix in of MCB SPN DB 8 way double door,IP 43 protection,Glazed door, isolated neutral bar,insulated bus bar assembly,mechanical strength of IK09 complete all as specified and directed.

2

-

-

... More
Supply and fix MCB TPN 63 Amps 'C' series 10 Ka, 240 volts include taking down old U/S MCB complete all as specified and directed.

3

-

-

... More
Supply and fix MCB SPN 32 Amps 'B' series 10 Ka, 240 volts include taking down old U/S MCB complete all as specified and directed.

3

-

-

... More
Supply and fix MCB SP 6 to 20 Amps 'B' series 10 Ka,240 volts include taking down old U/S MCB complete all as specified and directed.

10

-

-

... More
Supply and fixing Bulb holder angular PVC/Polycarbonate suitable for batten fittings complete all as directed.

3

-

-

... More
Supply and fixing LED Batten fitting 1x18 watts including cube rod, 230 Volts, bipin holders connector block etc.complete with all accessories internally pre-wired and including provision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23.0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting complete all as specified and directed.

8

-

-

... More
Supply and fix in repair of LED Luminarie 600mm x 600mm, 35/36 watt 220 Volt AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver suitable for roof ceiling including connecting up with the driver complete all as specified and directed.

30

-

-

... More
Material & labour for Sub main wiring with two runs of single core, FRLSH 6 sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi-standed copper conductor cable LT 1100 volts grade drawn through PVC casing capping of adequate size fixed on surfafce of wall/ceiling with all necessary fittings and accessaries and 1 run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 6 sqmm as earth wire (green in colour) run through casing capping and connected common earth dolly including taking out the old sub main wiring. Note : Two run of 6 Sqmm cable, one run of casing capping and one run of 6 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed.

99

-

-

... More
Supply & fixing Wall mounted fans AC single phase 230/ 240 V of size 400 mm sweep including taking down ceiling/wall mounted fan with all accesories and depositing MES Store yard complete all as specified and directed.

6

-

-

... More
Supply & fixing Ceiling fan of 1200mm working on BLDC Technology without remote with all its accessories, taking down ceiling/wall mounted fan with all accesories and depositing MES Store yard complete all as specified and directed.

8

-

-

... More
Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to earth lead wire 4 mm dia by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar, funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary excavation and earth works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I including taking out the old earthing material complete all as specified and directed.

2

-

-

... More
Taking down and refixing, old existing servicable MCB's SPN, SP, TPN, DPN for any other size/ type and refixed complete all as specified and directed.

2

-

-

... More
Schedule of Credit

-

-

-31768



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.