Military Engineer Services Tender

View complete overview of Meghalaya MES Tender

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date17 Oct 2024
Closing Soon19 Nov 2024
Tender Amount₹ 15,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Electric motor capacity 1.5 HP

1

-

-

... More
Electric motor capacity 2 HP

2

-

-

... More
Electric motor capacity 10 HP

1

-

-

... More
Supply and fixing the following spare parts as per the existing specification, size and make of Motors complete all as directed by Engr-in-charge.

-

-

-

... More
Ball bearing as per sample for 3 HP motor

4

-

-

... More
Ball bearing as per sample for 7.5 HP motor

2

-

-

... More
Ball bearing as per sample for 1.5 HP motor

2

-

-

... More
Ball bearing as per sample for 2 HP motor

4

-

-

... More
Ball bearing as per sample for 10 HP motor

2

-

-

... More
Repair/overhauling and testing of Sewage centrifugal pump sets by dismantling completely and replacing unserviceable ball bearing, shaft sleeve, gland neck ring gland rope, nut and bolts, pump bushing, coupling, rubber coupling etc. assembling back the complete pump and fixing alignment to the original position and coupling with motor and necessary alignment etc painting with of synthetic two coat enamel paint including scraping complete and writing MES/SM No, testing and commissioning all as directed by Engr-in-charge for following capacity :- . Note : (i) Spare parts shall be measured and paid separatly under relavent items, (ii) Painting and writting is deemed included in item rate quoted. Maintenance schedule :- (i) Checking for looseness of all the foundation and coupling nuts/bolts and rectification. (ii) Checking for proper functioning of all the voltmeter, Ammeter, starter, contactor etc and rectification. (iii) Checking for proper functioning of suction and discharge pressure gauges and rectification. (iv) Checking of leakage in gland packing, shifting base, bushes sluice valves, gate valves etc and rectification. (v) Checking for any undue noise of motor pump and rectification. (vi) Checking for proper aligment and rectification.

-

-

-

... More
3 HP centrifugal pump

3

-

-

... More
1.5 HP Centrifugal pump, Make - UT pumps and system pvt ltd

2

-

-

... More
10 HP Centrifugal pump, Make- Kirloskar

2

-

-

... More
2 HP Centrifugal pump Non clogging pump, Make-KSB

2

-

-

... More
Supply and fix in repair of impeller with nut and bolt suitable for following capacity pump set.

-

-

-

... More
3 HP Pressure filter pump

2

-

-

... More
3 HP FMR pump

2

-

-

... More
10 HP pump

2

-

-

... More
2 HP pump

2

-

-

... More
Material and labour for shaft welding Turning with nut and bolt suitable for following capacity pump set.

-

-

-

... More
3 HP FMR pump

1

-

-

... More
1.5 HP Pump

1

-

-

... More
2.0 HP pump

1

-

-

... More
10 HP pump

1

-

-

... More
Supply and fix in repair the following spare parts of the pumps as per the existing specification, size and make complete all as directed by Engr-in-charge.

-

-

-

... More
Coupling assembly for 3 HP capacity FMR pump set.

1

-

-

... More
Coupling assembly for 2 HP capacity Non clogging Centrifugal pump set.

1

-

-

... More
Rubber coupling for 3 HP capacity pump set.

2

-

-

... More
Rubber coupling for 2 HP capacity pump set.

2

-

-

... More
NRV for 3 HP pump capacity

2

-

-

... More
NRV for 2 HP pump capacity

2

-

-

... More
Ball bearing as per sample for 3 HP pump capacity

2

-

-

... More
Ball bearing as per sample for 1.5 HP pump capacity

2

-

-

... More
Ball bearing as per sample for 2 HP pump capacity

2

-

-

... More
Repair/overhauling of 7.5HP Air blower by dismantling completely and replacing unserviceable ball bearing, shaft sleeve, nut and bolts , Gears, V belt, pulley etc. assembling back the complete Air blower and fixing alignment to the original position and coupling with motor and necessary alignment etc with two coat synthetic enameled paint including scraping complete and writing MES/SM No, testing and commissioning all as directed by Engr-in-charge. Note : (i) Spare parts shall be measured and paid separatly under relavent items.(ii) Painting and writting including item rate.

2

-

-

... More
S&F in repair Pulley for 7.5 HP Air blower

1

-

-

... More
S&F in repair Bearing for 7.5 HP Air blower

2

-

-

... More
Supply and fill in repair Gear oil (Recommended oil grade is CASTROL HYOY B90/ SERVO GEAR SUPER90/ HP GEAR OIL X- P90/ BP SPIROL SUPER 90 EP

10

-

-

... More
S&F in repair Oil seal, Gasket for 7.5 HP Air blower

1

-

-

... More
S&F in repair Air filter for 7.5 HP Air Blower

2

-

-

... More
S&F in repair V Belt For 7.5 HP Air blower

1

-

-

... More
Supply and fix filter press - Hydraulic Motorised Sliding type having following specifications as mentioned below (i) Size ; 470mmx 470mm (18") (ii) No of Chambers : 17 Nos (iii) Plate thickness : 55+/- 2 MM (IV) Cake Holding Capcities: 125 Ltrs (v) Air Provision: Not Required (vi) Max operating Temperature: 80 to 85 Deg C ( vii) Max Operating Temp: 5 to 6 Bar (viii) Plate Closing : Hydraulic Hydraulic Details (i) Motor Power: ( 1 HPX 1500 RPM) (II) Cylinder Dia: 90mm (iii) Electric Supply : 3 Phase ,415 V Frequency 50 Hz (IV) Max Operating Temp : 5000PSI MOC OF FILTER PRESS (I) Filter Head: M.S (II) Follower: MS (III) Moving Plate: MS (IV) Rollers: MS (V) Plates: Non Pigmented While PP (VI) Fiber Cloth : PP Woven (vii)Tie Bar: MS (VIII) Distance Piece: MS (IX) In case of Hydraulic Press, Hydraulic Pack with Cylinder : MS

1

-

-

... More
S&F in repair Chemical dosing plant with high speed agitator having LDPE Tank Cap 150Ltrs ,Discharge 4 ltrs/hr , Pressure 4 Bar all as specified as directed by Engr-in-charge. Model CDS-2 INDION

1

-

-

... More
Material and labour for formation of consumables for bacteria formation having Gur, Flour, Cow dung on monthly basis in 200 Litre drum, Complete as directed and specified by Engr in charge

2

-

-

... More
Material and labour for media for FMR tank including replacing of old media drom FMR tank , Complete as directed and specified by Engr in charge

2

-

-

... More
S&F in repair 3 Ph LED Ammeter of flush mounting 96 x96 mm square flush pattern with selector switch, Make as above . Make L&T, Cat No. WL131010OOOO or equivalent make as specified in CA.

1

-

-

... More
S&F in repair 3 Ph LED Voltmeter 0-500 Volts 96 x96 mm square flush pattern with selector switch, Make L&T, Cat No. WL132010OOOO or equivalent make as specified in CA.

1

-

-

... More
S&F in repair Indicator lamps of different colors with holder 15 mm screw type.

3

-

-

... More
S&F in repair DOL starter for 2/3 HP Motor (Motor rating AC-3, 415V, 50 Hz, 3-Ph). complete all as directed.

1

-

-

... More
S&F in repair DOL starter for 7.5/10 HP Motor (Motor rating AC-3, 415V, 50 Hz, 3-Ph). complete all as directed.

1

-

-

... More
S&F in repair CT cast resin type suitable for 3 Ph LED Ammeter, of suitable VA burden

3

-

-

... More
supply and fix single phase preventer for electriacl panels all a specified and directed.

2

-

-

... More
Supply and fixing MCB 16 amps three pole C Curve ,breaking capacity 10 KA suitable for operaions of 415 volts AC 50 HZ with fixed type all as specified in SSR Part-I including making necessary electric connections complete all as specified and directed

2

-

-

... More
Supply and fixing MCB 32 Amps TPN, C Curve, breaking capacity 10 KA suitable for operaions of 415 volts AC 50 HZ with fixed type all as specified in SSR Part-I including making necessary electric connections complete all as specified and directed

2

-

-

... More
S&F 3-layer PP-R (Polyproplene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to walls, ceilings or laid in trenches etc.outer diameter of pipe 25 mm including taking down of old U/S PPR pipe, complete all as directed.

50

-

-

... More
S&F in repair Female thread coupling of size 25-3/4" complete all as specified and directed.

8

-

-

... More
S&F in repair Bib tap of size 20mm standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 20mm-125gms).

8

-

-

... More
Supply and fix in repair Non return valve of size 100 mm matching with existing NRV and Taking out old unserviceable NRV ISI marked including complete fitting item with jointing materials such as nuts, bolts, washers and rubber gasket etc of suitable size all as specified and directed.

2

-

-

... More
Supply and fix in repair butterfly valve of size 100 mm and Taking out old unserviceable Butterfly valve ISI marked including complete fitting item with jointing materials such as nuts, bolts, washers and rubber gasket etc of suitable size all as specified and directed.

3

-

-

... More
Supply and fixing in replacement of Old/UNSV water Pressure gauge 4"dial 0-14 kgs rating complete with jointing material make as per sample and all as directed by Engineer-in-Charge

2

-

-

... More
Taking out old unservicesble gate valve and supply and fix new 50mm dia gun metal gate valve conforming to IS with iron wheel head screwed both ends for iron pipe all as specified and directed.

1

-

-

... More
Taking out old unservicesble gate valve and supply and fix new 25mm dia gun metal gate valve conforming to IS with iron wheel head screwed both ends for iron pipe all as specified and directed.

2

-

-

... More
M&L for cleaning of complete sewage treatment plant including aeration tank, oil and grease chamber, FMR tank, final treated water tank, secondary filtration tank (02 nos) etc by draining out the Sewage water by using exit valve or by own high capacity dewatering system and cleaning all the algae formation inside the tank by scrubbing the walls of the tanks using wire brush and scrubber of Umroi Military Station (Umroi Cantonment, Barapani) by engaging requisite resources, manpower and T&P etc., up to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. Notes: (a) The contractor shall carry out normal maintenance of the sewage system and cost thereof shall be deemed to have been included in the quoted rate. However extensive repair where involved shall be intimated to the contractor seperately and repairs thereof shall be undertaken against this contract. (b) T&P as required for the work shall be organised by the contractor under their own arrangement. (c) For any default/delay in the work, penal recovery shall be effected from payments due to the contractor in terms of PS clause. (d) Labour/workmen engaged by the contractor shall take all requisite preventive safety measures and adequate precautions to avoid any health hazard and the department shall not be responsible any eventualities in this regard.

1

-

-

... More
M&L for removal of solid sludge from cake formation machine on weekly basis by deploying two labours and depositing the sludge at a location specified by Engr-in-charge (a) T&P as required for the work shall be organised by the contractor under their own arrangement. (b) For any default/delay in the work, penal recovery shall be effected from payments due to the contractor in terms of PS clause. (c) Labour/workmen engaged by the contractor shall take all requisite preventive safety measures and adequate precautions to avoid any health hazard and the department shall not be responsible any eventualities in this regard.

10

-

-

... More
Supply & fix in repair of cake formation machine of STP by repalcing the existing filtration cloth with new one complete all as specified and directed.

5

-

-

... More
M&L for reapair of cake formation machine of STP by repalcing the existing defected drain valves with the new one complete all as specified and directed.

6

-

-

... More
Material and labour for overhauling of filter media MGF800 Plant including Removing and refilling of filter media incuding the following items (i) Fine silex-320 KG (ii) Coarse silex-200 KG (iii) Pebbles(1/2")- 200 KG (iv) Pebbles(3/4")- 200 KG (v) Pebbles(1")-200 KG

1

-

-

... More
Material and labour for overhauling of filter media ACF 1200 Plant including Removing and refilling of filter media incuding the following items (i) Pebbles(1/2")- 200 KG (ii) Pebbles(3/4")- 200 KG (iii) Pebbles(1")-200 KG (iv) Activated Carbin 1100 ID-450 KG

1

-

-

... More
Material and labour for Testing of Raw sewage and treated water , Following parameters is tested on regular basis from any recogonised Govt lab or authoeised lab and Testing certificate is submitted to GE Umroi on regular basis. Complete as directed and specified by Engr in charge. (i) PH(For Raw sewage and traeted water) (ii) BOD(For Raw sewage and traeted water) (iii) COD(For Raw sewage and traeted water) (iv) TSS(For Raw sewage and traeted water) (v) Res.Cl (For traeted water only) (vi) E-Coli (For Raw sewage and traeted water)

6

-

-

... More
Repair/replacement of old unsv Air Grid system of FMR tank by replacing the existing grid with new one. new grid should be same as existing grid comprising of PVC pipe of dia 90mm PN 16 ISI marked of total length not less than 18m and making grid by using TEE, end cap, flanges of specification 90mm working pressure 6 kgf/cm2. PVC pipes of grid should be perforated for blowing of air and should covered with synthetic rubber sleeve cover including clamp complete all as directed, Note : Material and labour, T&P and transport shall be included in the quoted rate.

2

-

-

... More
Cleaning ,desilting of Collection Chamber upto 20000 Gallon capacity, of any size & depth from solid liquid/liquid mud etc, and removing SOLID/LIQUID/FOREIGN MATTER/MUD and deposited to 4 km to 5 km from site in the hygienic manner and deposited material shall be dump 0.75 m below underground the natural ground level (Rate will be inclusive for excavation of soft/loose soil for deposited material), complete including pumping out liquid and liquid sluge with pumping arrangements, labour and machine as required, complete all as specified and directed. Note : (a)Contractor shall arrange the sewage suction machine or sewage pump of minium 5HP along with the equipments to clean the sewage line by super suction machine, MH, septic tank & soakage well etc. and cost in this respect shall be deemed included in the quated rates of respective items and no extra payment on this account shall be made. (a) Labour/workmen engaged by the contractor shall take all requisite preventive safety measures and adequate precautions to avoid any health hazard and the department shall not be responsible any eventualities in this regard. (b) Rate will be inclusive for excavation of soft/loose soil for deposited material.

3

-

-

... More
M&L for complete removal of old painted surface and applying two coats of anti fungal paint over a coat of alkali resistant primer on wall surface upto 10m height, complete all specfied and directed by the Engr-in-charge. Note : rate shall be inclusive of scaffolding.

150

-

-

... More
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as directed by the Engr-in-charge.

200

-

-

... More
S&F in repair PVC (SWR) pipe 110 mm bore single socketed ,in any length with rubber ring joints, laid in floors,with clamp and all necessary fitting, complete all as specified

24

-

-

... More
Demolition of cement concrete (Unreinforceed) of any description in ground floor n exc 15cm thickness (Below or above ground level) complete all as directed by the Engr-in-charge.

6

-

-

... More
Material and labour for Cement concrete 1:3:6 Type C-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed by Engr-in-charge.

6

-

-

... More
M&L for 25 mm PCC 1:2:4 Type B0 using 12.5 mm graded stone aggregate as in path, concrete surface even and smooth without using extra cement, complete all as directed by the Engr-in-charge.

55

-

-

... More
M&L for for 75 mm PCC 1:3:6 Type C2 using 40 mm graded stone aggregate as in sub base , concrete surface even and smooth without using extra cement complete all as directed by the Engr-in-charge.

60

-

-

... More
S&F 3-layer PP-R (Polyproplene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to walls, ceilings or laid in trenches etc.outer diameter of pipe 90 mm including taking down of old U/S PPR pipe, complete all as directed.

40

-

-

... More
Supply and fix in repair Sluice valve of size 100 mm matching with exisiting and Taking out old unserviceable NRV ISI marked including complete fitting item with jointing materials such as nuts, bolts, washers and rubber gasket etc of suitable size all as specified and directed.

2

-

-

... More
Supply Only Calcium hypochlorite Available Chlorine Percent by mass by volume (as CI): 65-70% Packing in 45 kg /50kg/100kg plastic recycled jars Availability of Test Report from a taboratory/study/centre of any state University (a university established or incorporated by a provincial Act or by a state Act) OEM must possess the following valid certificates: FSSAI, ISO 9001, ISO 14001, ISO 45001 superior quality suitable for treatment of drinking water and swimming pool all as specified and directed by Engr-in-Charge. Make : As per Approved make list of E-in-C.

910

-

-

... More
Supply only bleaching powder of grade confirming to IS-1065-1989 (2nd Revision) minimum markable chlorine 33.5% by mass packed in HDPE bag of 25 Kg capacity ISI marked complete all as specified. Make: E-in-C's approved make or equivalent Eastern Command approved make. Note: (a) The contractor shall produce manufacturers "Certificate of Compliance" indicating date of manufacturer in original alongwith every consignment of supply. (b) Test certificate from Govt approved Test Laboratory shall accompany with every consignment of supply to ensure that the materials supplied are in with conformity with relevant IS.

15

-

-

... More
Supply, install, testing and commissioning of Cubical type CPRI approved dust and vermin proof and water proof LT Panel of size 75x60x45cm out door type floor mounted including PCC (1:3:6) type C1 in foundation grouting & fabrication totally enclosed with double door factory made out of 16 guage MS Sheet and angle iron of 50x50x6 mm size duly painted with two coats of red synthetic enamel paint over a coat of red oxide Primer with locking arrangement made of MS Angle iron frame work and CRCA SHEET OF 3.15mm thick as per 5039 duly painted with powder coated paint of approved shade . The Panel shall be suitable for 415 Volts ,50 Hz 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar ( 1.5 times the incoming switch gear current rating) with suitable size of PVC Copper conductor,thimbles glands and shall be completed all as directed with following accessories. The cost of the PCC Pedestal will be as per the manufacturers instruction.The Panel will be comprises of the following. Incoming :- (a) MCCB, 4 Pole, 100A, 415 V, 16 kA.- 01 No. Outgoing :- (a) MCCB, 4 Pole ,63 Amps, 16 KA,415 V-01 Nos (b) Digital Voltmeter 0-500 Volt Range with Selector Switch- 01 Nos (c) Digital Ammeter 0-100 Amps Range with Selector Switch- 01 Nos Incl CT coil RYB Phases ( CT Ratio 200/5A) (d) Al bus bar 4 strip -250 amps (e) Automatic Star Delta Starter, 415 Volts, 50 Hz Suitable for Submersible Pump Motor 7.5 HP- 01 Nos (f) Indicator Lamp ,Set of three, RYB- 01 Set ( Set of three) with holder and fuse arrangement.

1

-

-

... More
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for foundation of pole and laying of CI/GI/DI/PPR pipe and getting out in any type of soil, complete all as specified and directed by Engr-in-charge.

20

-

-

... More
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed by Engr-in-charge.

2.4

-

-

... More
Returning filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engr-in-charge.

17.6

-

-

... More
Supply and Fix Dosing Pump of Discharge 4LPH, Max Working Pressure 5.5 Kg/cm2 working on Single Phase 230V , 50 Hz all as specified and directed by Engr-in-charge

1

-

-

... More
Schedule of Credit

-

-

-17197



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.