Military Engineer Services Tender
View complete overview of Meghalaya MES Tender
Costs
EMD
₹ 1,04,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665471_1Bid Award Id
ViewTender No
8782/SHL/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
308
-
-
M & L for Cement concrete in foundation, filling in mass concrete of pole and stay concrete for pole and stay, type B-2 1:2:4 (using 40 mm graded crushed stone aggregate) complete all as specified and directed.
6
-
-
M & L for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges, type C-1, 1:3:6 (using 20 mm graded crushed stone aggregate) for coping complete all as specified and directed.
1
-
-
Dismantling of ACSR or AAC conductors complete all as specified and directed.
3
-
-
Dismantling steel poles/ struts, any size complete all as specified and directed
12
-
-
Dismantling stay assembly (demolition of concrete, etc. and excavation measured separately) complete all as specified and directed.
4
-
-
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. complete all as specified and directed.
8
-
-
Dismantling cross-arms of M.S. channel or angle sections anticlimbing devices etc. complete and setting asidefor re-use with in 50m etc complete all as specified and directed
4
-
-
Dismantling insulators any type, any size complete all as specified and directed.
26
-
-
Demolition steel pole of any description and in any position not otherwise specifically provided for floor,mass foundation PCC of stay, pole etc. complete all as specified and directed
6
-
-
S&F aluminium conductor steel re-inforced (ACSR) of size 6/1x2.59 mm (weasal) and 6/1x2.11 mm for HT lines on steel tubular poles, stretching without kinks and bends, binding with flat aluminium type conductor (rates inclusive) binding wire confirming to IS:5613(part1/sec2)-1985 complete all as specified and directed.
2
-
-
Supply, erecting, testing and commissioning of Steel tubular swaged poles complete with iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) complete all as specified and directed. [Note: - (i) Excavation, earth work and PCC and painting of pole shall be measured and paid for separately under relevant item of BOQ]
4
-
-
M&L for Stay assembly complete with stay rod 20 mm,stay rod, stay anchoring either provided by base plate incl all accessories as shown in plate No.1 of SSR Part-I including galvanised steel wire stranded stay strand of size 7/4mm,stay clamps,guy wire,etc excluding loop type stay insulator complete all as specified directed. Note: The cost of Excavation, earth work, PCC, loop type insulator shall be measured and paid separetely under relevant item of BOQ
2
-
-
M&L for Loop type insulator, vitreous porcelain, white, brown or green: Large size, with overall dimensions 90mmx140mm, clearance of hole 25.5mm complete all as specified and directed.
2
-
-
M&L for fixing in repair of HT Lightning arresters for outdoor use, expulsion type complete incl taking down with all fittings, transmission class, discharge capacity 65kilo amps, minimum working pressure 11000 volts grade conforming to IS complete all as specified and directed. Note :The cost for neccesaary jumpers for connecting the LA shall be measured and paid separetely under relevant item of BOQ
8
-
-
S&F Air break switch out door type triple pole, 11000 volts mechanically operated Air break switch (GOD), mounted on insulators and steel frame, with mechanically operating mechanism worked from ground level suitable for current rating up to 200amps mounted on insulators including all accessories ie pipe clamp,nut,bolts& washers etc complete all as specified and directed.
8
-
-
M&L for Structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, duly welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coats of aluminium paint complete all as specified and directed.
2
-
-
S & F Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green: Single disc assemblyfor tension with tension clamps for conductors, working pressure 11000 volts confirming to IS:3188-1980 complete all as specified and directed.
6
-
-
S & F pin type,porcelain,vitreous,white,brown insulator including galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 150 mm height,150mm dia for 11000 volt grade, confirming to IS:731-1971 complete all as specified and directed.
18
-
-
Supply and fixing Anticlimbing device for HT poles spikes type fabricated out of MS flat iron 50x6mm, MS bars (round) of 10mm dia including nuts bolts washers etc. having spikes of 200 mm long duly welded -12 Nos. made in two halves made to shape in suit the cross section of pole including painted with two coats of sythetic enamelled aluminium paint over a coat of red oxide primer, complete all as specified and directed.
0.5
-
-
M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter,figures and conventional skull and bones in signal red colour and fix with including MS clamps, bolts and nuts of approved size, for HT 25x20 cm including taking out of old one complete all as specified and directed.
40
-
-
Restretching/ restringing of existing loose Overhead , ACSR conductor wire including GI wire along the span between poles (upto 60 mtr approx) to maintain sagging within the permissible limit, including winding/rewinding/joining with Aluminium winding wire in case of breakge of conductor, size of winding wire shall not be less than 2 mm complete all as specified and directed. Note : (i) Nothing extra is admissible on account of jointing material and labour in case the conductor breaks during stretching.
10
-
-
Trimming/cutting tree branches with clearing space upto 2 meter from the over head conductor's any side along the span between poles (upto 60 mtr approx), all around for HT distribution system complete all as specified and directed. [Note- The team for trimming should be assisted with one Electrcian shall be taken shutdown from JE Incharge and proper enter in to the register at Power house and complete the work within the time, and clear the shut down from main power house after completion the work.
90
-
-
Painting of 2 pole structures comprising of cross arms, supporting angle iron, clamps, nuts & bolts complete with 1 coat of aluminium paint over existing surface with black and Red colour in alternate layers of 25 cm upto 1.5 metre above the coping after scraping old painted surface complete all as specified and directed.
16
-
-
Painting of 4 pole structures comprising of cross arms, supporting angle iron, clamps, nuts & bolts complete with 1 coat of aluminium paint over existing surface with black and Red colour in alternate layers of 25 cm upto 1.5 metre above the coping after scraping old painted surface complete all as specified and directed.
8
-
-
M&L for Aluminium painting to cross arms "V" type or straight type, clamps, in position on 11 metres long Steel tubular pole after throughly cleaning the surfaces including bolt nuts etc. complete all as directed by Engr-in-charge.
80
-
-
M&L for Painting of HT poles with One coats of sythetic enemal paint with black and Red colour in alternate layers of 25 cm upto 1.5 metre above the coping and one coats of aluminium paints above 1.5 m from coping upto the tip of the pole complete all as specified and directed.
80
-
-
Supply, laying, commissioning and testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor,11000 volts grade, cross-sectional area 120 Sqmm 3 core complete all as specified and directed.
480
-
-
Supply, laying, commissioning and testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor,11000 volts grade, cross-sectional area 95 Sqmm 3 core complete all as specified and directed.
560
-
-
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
2
-
-
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
2
-
-
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
1
-
-
M&L for laying unreinforced pre cast concrete cable cover HV Type 1 flat size 300mmx180mmx40mm complete all as specified and directed.
5200
-
-
M & L for Sand cushioning for underground cable 8cm before laying the cable and 15cm (punned down to 18 cm) after laying and stretching the cable complete all as specified and directed.
Note: Punned down thickness i.e 18cm shall be measured and paid.
84
-
-
M & L for GI pipe light grade of size 100 mm dia laid in trenches/ wall for protection of cable complete all as specified and directed.
24
-
-
M & L for GI pipe light grade of size 80 mm dia laid in trenches/ wall for protection of cable complete all as specified and directed.
24
-
-
Suppply and fix Precast cement concrete cable route marker indicator of size 600mx 300mm x50mm having "MES HT CABLE" written by embossing or engraved over surface of the route marker, fixing over the route of existing HT cable complete all as specified and directed.
255
-
-
Earthing complete with galvanised steel earth plate electrode 600mmx600mm x6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr deep below normal ground level connected to in and including galvanised iron strip 32x6mm upto test point including providing test point inclulding funnel,wire mesh, charcoal dust, salt etc and 40mm dia bore 7.5 mtr long medium grade GI protection pipe for earth strip and GI watering pipe 20mm dia bore medium grade with concrete earth pit of PCC type C1 (1:3:6, using 20mm graded crushed stone aggregates) 50mm thick precast RCC type B1, (1:2:4, using 20mm graded crushed stone aggregates) pit cover reinforced with 8mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 10 mm dia including necessary excavation and earth work in soft/loose soil and disposal of spoils to a distance n.exc 50m and necessary connection and testing complete all as shown in electrical plate No 3 of SSR Part-I, 2009 including taking down old unserviceable earth plate with all accessories complete all as specified and directed.
[Note:- The rates quoted deemed to include the cost of Earth test point and earth lead and protection pipe upto 7.5 meter beyond the earth plate electrode]
16
-
-
Earthing complete with galvanised steel earth plate electrode 600mmx600mm x6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr deep below normal ground level connected to in and including galvanised iron wire of 4 mm dia upto test point including providing test point inclulding funnel,wire mesh, charcoal dust, salt etc and 20mm dia bore 7.5 mtr long medium grade GI protection pipe for earth lead and GI watering pipe 20mm dia bore medium grade with concrete earth pit of PCC type C1 (1:3:6, using 20mm graded crushed stone aggregates) 50mm thick precast RCC type B1, (1:2:4, using 20mm graded crushed stone aggregates) pit cover reinforced with 8mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 10 mm dia including necessary excavation and earth work in soft/loose soil and disposal of spoils to a distance n.exc 50m and necessary connection and testing complete all as shown in electrical plate No 3 of SSR Part-I, 2009 including taking down old unserviceable earth plate with all accessories complete all as specified and directed.
[Note:- The rates quoted deemed to include the cost of Earth test point and earth lead and protection pipe upto 7.5 meter beyond the earth plate electrode]
4
-
-
M & L for Replacement of GI strip of size 32x6mm from test point to transformer or other places complete all as specified and directed.
15
-
-
M & L for replacement of Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
30
-
-
M & L for attending fault of HT overhead lines by Carrying out inspection/ emergency inspection, inspection of insulators of HT overhead lines pole to pole carefully, thoroughly after switching off by taking proper shutt down from MRS necessary existing system i.e isolator switches, GODs, VCBs etc. after wind storm, heavy rain, thunder storm etc., check thoroughly by expertise team, tracing out the fault and restore the supply by necessary repairs i.e. applying drop out fuses, jumpering, replacing the insulator, HT overhead lines incl maggering/ servicing complete all as specified and directed.
[Note : (i) The inspection will be carried out by skilled electrician and expert staff deputed by the contractor on direction/ information from JE E/M/Engr-in-charge.
(iii) The damaged/ worn out parts replaced will be measured and paid separately under relevant items of BOQ and the same will be treated as supply only.
5
-
-
Supply only Drop out fuse wire bimetallic of rating 30 amps suitable for 11 KV Air break switch/GODs complete all as specified and directed.
100
-
-
Supply only Drop out fuse wire bimetallic of rating 60 amps suitable for 11 KV Air break switch/GODs complete all as specified and directed.
250
-
-
Boring of holes in any type of soil/ driling/augering under road, pavement hard standing by trenchless technology using horizontal driling machine/manually upto depth as required on site complete all as specified and directed.
18
-
-
M & L for attending fault of HT UG cables by Carrying out inspection, emergency inspection, periodical inspection of underground HT cable network after informed by JE/Engr-in-charge telephonically to the contractor in case emergency after wind storm, heavy rain, thunder storm, natural beark down of supply, by disconnecting necessary connections of 11 KV HT cable from VCB panel, transformer, 2 pole/ 4 poler structure any size, taking out loop manually, carefully by necessary earth work carefully to avoid any damage of HT UG cables, trace out the fault by cable fault locator machine and replacement of old end termination with new end jointing kit, aluminium lugs, nut bolts and washers etc. connecting, thimbling by crimpling tool properly, strenghtening the all joints in to panel board,GOD, transformer VCB etc. passing through cable protection pipe 100/80mm dia existing pipe, sand cushioning including, spreading,leveleing, returning filling, testing on completion after repair complete all as specified and directed.
[Note: (i) The inspection will be carried out by skilled electrician and expert staff deputed by the contractor on direction/ information from JE E/M/Engr-in-charge. (ii) The damaged/ worn out parts replaced will be measured and paid separately under relevant items of BOQ and the same will be treated as supply only.
6
-
-
Supply only Aluminium lugs suitable 70 sqmm 3 core HT UG cable complete all as specified and directed.
45
-
-
Supply only Aluminium lugs suitable 95 sqmm 3 core HT UG cable complete all as specified and directed.
45
-
-
Supply only PVC insulation tape 20 mm x7.5mtr long ISI marked good quality adhessive complete all as specified and directed.
75
-
-
Supply only PVC insulation tape 15 mm x7.5mtr long ISI marked good quality adhessive complete all as specified and directed.
82.5
-
-
M & L for attending fault of defective transformer step down 11 KV / 0.433 upto 750 KVA transformer any make, plinth/ floor/ pole mounted, indoor/ outdoor type, inspecting the transformer, meggering, step opening, removing the top cover of transformer, detecting the fault, rectfying the defect at site (Umroi mil stn, Jackwell Barapani area) except major fault of burnt winding or other. and reassemble the same incl minor repairs i.e. tightening all loose connections at HV/LV bushings, any portion, spare parts of the transfomer and replace the gasket, cleaning outer surface by using cotton waste, panting complete all as specified and directed. Note : (i) The damaged/ worn out parts replaced will be measured and paid separately under relevant items of BOQ.
12
-
-
M & L for removing from site by disconnecting all connections of defective step down 11 KV / 0.433 any capacity from 25 KVA upto 750 KVA transformer any make, plinth/ floor/ pole mounted, indoor/ outdoor type, (Umroi mil stn, Jackwell Barapani area), transporting/ lifting with required T&P, hydra machine etc. to local/ authorised work shop for carrying out major repair of the transformer, detecting the fault, step opening of the transformer, including spray painting. A factory test should be carried out after repair and before dispatch of the transformer. including transporting carefully, refixing back to original position complete all as specified and directed.
4
-
-
[Note: (a) Dismantling/ reassembling, at work shop shall be included in quoted rates (b) lifting, transportation from site to work shop and refixing back to original posittion shall inculded in quoted rates (c) Dehydration/filteration & trf oil shall be mesured and paid separetely under relevant item of BOQ and treated as supply only
(d) Spray painting, nuts, bolts and washer deemed to be included in the quoted rate. (e) The cost of silica jel, rubber gasket, temperature gauge, breather assembly, gate valves shall be measured and paid separetely under relevant items of BOQ (f) Rewinding part or entire windings, replacement of LV / HV bushing/ spindles/ copper wire wt. for rewinding of HV / LV coils / tap changer etc will be measured and paid for separately under relevant items of BOQ. and treated as supply only (g) Topping up of transformer oil (if required) shall be mesured and paid separetely under relevant item of BOQ and treated as supply only. (j) The neccesary T&P,hydra machine shall be provided by the contractor and the same shall be included in quoted rates)
-
-
-
Repair/ reconditioning of winding of LV/HV leg coil aluminium/ copper as per existing winding for transformer of capacity 63 KVA to 750 KVA to be done only in case where only insulation is damaged and conductor strip is intact i.e. not deformed. This work will involve all turns of leg coil to be reconditioned removing complete insulation from conductor strip, cleaning of conductor, wrapping of conductor with fresh DPC insulation and remaking of LV leg coils with reconditioned strip for use in transformer under repairs complete all as specified and directed.
120
-
-
Rewinding complete of any HV/ LV leg coil of aluminum for transformer of capacity 63 KVA to 750KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly to match with the existing original winding coils and turn ratio complete all as specified and directed.
42
-
-
Rewinding complete of any HV/LV leg coil of copper conductor for transformer of capacity 63 KVA to 750KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly to match with the existing original winding coils and turn ratio complete all as specified and directed.
80
-
-
HT 11 KV brass spindle, threaded with washers, nuts, lock nut and rubber seal suitable for transformers of any make /Type rating from 100 KVA to 250 KVA complete all as specified and directed.
8
-
-
HT 11 KV brass spindle, threaded with washers, nuts,lock nut and rubber seal suitable for transformers of any make /Type rating from 315 KVA to 750 KVA complete all as specified and directed.
10
-
-
LT 433 V, brass spindle threaded with washers, nuts, lock nuts, and rubber seal suitable for existing transformers rating from 100 KVA to 250 KVA complete all as specified and directed.
15
-
-
LT 433 V, brass spindle threaded with washers, nuts, lock nuts, and rubber seal suitable for existing transformers rating from 315 KVA to 750 KVA complete all as specified and directed.
15
-
-
Supply only transformer oil as per IS 355 and minimum di-electric strength 30 KV complete all as specified and directed.
2100
-
-
M & L for Filteration and dehydration of transformer oil by centrifuging machine includng heating continuously till obtaining the desired dielectric strength complete includuing taking result of transformer oil before/after filteration and dehydration of transformer oil complete all as specified and directed. [Note: Centrifuging machine shall be arranged by the contractor]
8100
-
-
Replacement of temperature gauge circular dia type of standard size and suitable for existing indoor/ outdoor type transformer of 100 KVA to 750 KVA capacity all as specified and directed.
15
-
-
Replacement of breather assembly duly filled with silica gel suitable for existing transformer complete all as specified and as directed.
10
-
-
Supply and filling of silica gel in to the existing breather assembly of transformer complete all as specified and directed.
5
-
-
Replacement of gun metal gate valve upto 40mm for drainout of transofrmer oil at the bottom of the transformer complete all as specified and directed.
6
-
-
Material and Labour for repairing and refixing the transformer tap changing mechanism for varying HT voltage in steps for transformer capacity from 100 KVA to 750 KVA complete all as specified and directed.
2
-
-
M&L for Painting of the transformer of any capacity 25 KVA to 160 KVA complete with synthetic enamel paint as existing earlier by spray painting including filling cavities with filler one coat after cleaning all dust etc and marking SM/MES No on the transformer at both site in letter (white colour) complete all as specified and directed.
7
-
-
M&L for Painting of the transformer of any capacity 200 KVA to 750 KVA complete with synthetic enamel paint as existing earlier by spray painting including filling cavities with filler one coat after cleaning all dust etc and marking SM/MES No on the transformer at both site in letter (white colour) complete all as specified and directed.
18
-
-
M&L for Writing of MES/SM No on the transformer/Panel with synthetic enamel paint after scraping the old painted surface complete all as specified and directed.
25
-
-
M&L for Gasket sets for transformer tank 100 KVA to 250 KVA capacity with nuts, bolts etc complete all as specified and directed.
7
-
-
M&L for Gasket sets for transformer tank 315 KVA to 750 KVA capacity with nuts, bolts etc complete all as specified and directed.
18
-
-
M&L for repair of leakage of oil from transformer fins, conservator tank, body of transformer, by welding, grinding process at the site or work shop through welding machine complete including welding materials,T&P completion on testing complete all as specified and directed.
2
-
-
M & L for shifting of transformer within complex 100 KVA to 750 KVA as per site requirement from 2/ 4 pole structure/ platform to another plateform or plateform to 2/4 pole structure including transportation & labour, T&P, hydra machine required for shifting of the transformer complete including disconnecting the cable/ connections and connecting the cable at new shifted site complete all as specified and directed. Note: The rates quoted are deemed to be included for disconnecting and connecting of connections any type and T&P, hydra machine required. No extra amout be paid on this account.]
2
-
-
Repair to platform of existing transformer of size (2.60 M x 2.0M x 1.20 M) disconnection all electric connection, disconnecting the existing earthings, taking down the transformer from damage plateform and put at another location during repair the plateform and disconneccting and connecting/fputtingfixing the transformer after repair at original position including dismantling/removing old cracked PCC at the top portion of the transformer 30cm thick, crack plaster,and replastering the same with fair finish on all sides & top of the plateform,including painting, levelling with providing additional PCC for repair the damage portion over the transformer plinth/ platform complete all as specified and directed. Note : (i) The rate of taking down of the transformer from plateform and refixing the same after repair of transformer deemed to be included in quoted rate (ii) The cost of necessary T&P, hydra lifting machine shall be included in quoted rate.
1
-
-
Taking out VCB trolly from the VCB chamber after switching off all necessary system , calibrating/ servicing, greasing the gear operating mechanism,charging spring stiffness, ensure the contact force of spring and setting of relays IDMT/ micropressor type adjusting with the tripping fault level, tuning with the state elctricity department tripping system, so that the fault in MES system should not get transfered onward (IDMT Alstom or approved make with 2 over current and 1 Earth fault element, CDG 32 replacing of damaged/ worn out part of VCB for any type/ any capacity of matching with existing VCB make Schneider, Crompton Greaves, Seimens etc. complete all as specified and directed. Note : (i) The damaged/ worn out parts replaced will be measured and paid separately under relevant items of BOQ.
6
-
-
Supply only indication lamp red, yellow, amber, white, blue or green in colour of 22.5mm dia with fuse contacts suitable for 11 KV HT VCB panel supply complete all as specified and directed.
6
-
-
Supply only Digital ammeter (0-100A) suitable for 11 KV VCB with in-built selector switchflush pattern square type matching with existing slot including wiring duly interconnected with CT complete all as specified and directed.
2
-
-
Supply only Digital voltmeter 0-11 KV suitable to function with in-built selector switch suitable for 11KV HT VCB panel flush pattern matching with existing surface including wiring, dult interconnected with Potential transformer (PT) complete all as specified and directed.
2
-
-
Supply only Over current and Earth fault IDMT relay complete matching with existing 11 KV of VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
2
-
-
Supply isolating contact -flat type variant 630 amps suitable for VCB make Schneider, crompton greaves, seimens etc omplete all as specified and directed.
1
-
-
Supply only flexible connections variant 800A, up to 25 KA capacity suitable for VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Breaker wheel Nylon VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Breaker wheel cast iron suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Operating Handle for (dia 6mm hex) suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Interlock Handle (dia-6mm hexsuitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Guide Bush suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Closing coil (24V DC-110V DC) suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Triping coil (24V DC-110V DC) suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Release coil assembly with plunger without coil suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Trip coil Box assembly with single Plunger without coil suitable for existing VCB make Schneider, crompton greaves, seimens complete all as specified and directed.
1
-
-
Supply only Pin for release prop suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Ratchet wheel assembly including ratched pin suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Trip roller complete suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Motor cutt-off switch lever : including (manual release lever-Nylon,Buffer-opening spring opening buffer, Buffer for closing spring,operating counter) complete suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Spring charging motor 110V AC/DC complete suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Breaker auxiliary switch 6NO+6NC complete suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Main drive shaft assembly complete suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Trip Fork linkage assembly complete suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Over Ride stop complete suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Over Ride stop Pin complete suitable for existing VCB make Schneider, crompton greaves, seimens etc complete all as specified and directed.
1
-
-
Supply only Potential transformer three single phase draw out type 11 KV/rt3/110V/rt3 class 0.5, burden 100 VA with risers complete suitable for HT 11KV panel complete including testing and commissioning complete all as specified and directed.
1
-
-
Supply only Epoxy Rasin cast CT of ratio 400-200/ 5-5 class 0.5/ 5P10, burden 2.5 VA/15 VA including wiring and testing with primary and secondary injection kit including to match with the existing system testing commisioning complete all as specified and directed.
1
-
-
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
2
-
-
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
1
-
-
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
1
-
-
S&F HT feeder pillar box 2way suitable for HT cable of size 95aqmm 3core including all accessories all as specified and as directed. Note: Drawing must be approved by GE before procurement.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements