Military Engineer Services Tender

View complete overview of Meghalaya MES Tender

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date10 Feb 2020
Closing Date15 Feb 2020
Tender Amount₹ 10,08,892 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling of wall/ceiling boards (fibre, pulp,insulation, etc.) or insulation boards/ slab/blankets, any thickness including cover fillets.

80

-

-

... More
S&F 4mm thick Non asbestos fibre cement Bldg Board fixed with screws to timber frame work as in ceiling complete all as specified and as directed.

80

-

-

... More
Dismantling timber scantlings, 40 sqcm and over in section in any position as in unframed work complete as directed.

0.25

-

-

... More
M&L for 2nd class hard wood as in scantling, clean sawn, timber fixed complete all as specified and directed.

0.25

-

-

... More
Dismantlling timber as in fillets rails posts, rafter, purlins etc under 40 Sqcm in section in unframed work.

100

-

-

... More
M&L 2nd class hard wood Plain fillets square rectangular or tringular in section clean sawn on one face or edge in section wrought secured with nails or brads sectional area exc 13 Sqcm but n.exc 25 Sqcm complete all as specified and as directed.

75

-

-

... More
M&L for 2nd class hard wood plain fillets bullnosed, splayed, chamfered or rounded on one edge or face in section clean sawn, fixed with screws sectional area exc. 6 sqcm but n.exc.13 sqcm etc complete all as specified and directed

25

-

-

... More
Taking down cement plaster on brick, concete or stone walls etc inlcuding racking out joints, hacking for key, scrubbing down with water etc including removing debris from site complete all as directed.

140

-

-

... More
M&L for Rendering, 15 mm thick plaster in cement sand mortar ( 1:4), in two layers, top 5 mm thick with approved Water proofing compound @ 3% by the weight of cement or as per manufacturers instructions over a layer of 10 mm thick base coat complete all as specified and as directed by Engineer-in-Charge. Note WPC shall be measured and paid separately.

70

-

-

... More
M&L for rendering 10 mm thick cement plaster in cement sand mortar (1:6) on fair faces of brickwork or concrete work , finished even and smooth using extra cement complete all as specified and directed.

60

-

-

... More
M&L for 5mm thick plaster in cement sand mortar (1:3) on fair faces of concrete surfaces of ceiling including finishing even & smooth without using extra cement. complete all as specified and directed.

10

-

-

... More
Supply only integral water proofing compound (liquid) , ISI marked.complete all as specified and as directed.

9

-

-

... More
M&L for preparation of new or previously undecorated plastered surfaces of walls including cornices, plasters etc and applying three coats of white wash including necessary preparation etc complete all as specified and directed.

50

-

-

... More
M&L for preparation of new or previously undecorated plastered surfaces of wall and applying two coats of acrylic emulsion distemper over a coat of primer etc complete all as specified and directed

30

-

-

... More
M&L for preparation of new plastered surfaces of wall and applying two coats of white or tinned with cement base paint over a coat of wall primer etc complete all as specified and directed

60

-

-

... More
M&L for preparation of new or previously undecorated plastered surfaces of ceiling and applying three coats of white wash including necessary preparation etc complete all as specified and directed.

10

-

-

... More
Taking down chowkhat with shutter (without taking off shutter from the frame) and area exc 1.5 sqm but n.exc. 4.00 sqm each with all builders hardwares etc complete all as specified and as directed.

10

-

-

... More
S&F pre laminated solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam single piece extruded pvc profile and edgs will be painted to match with prelam sheet , PVC sheet are to be reinforced with 19x19mm MS square tube EPDM rubber gasket weather seal shall be provided through out the frame. The profile shall be mitre cut at two corners and joint by insrting 2 nos of 150mm long backets of 15mmx15mm MS square tube inside the 19mmx19mm MS square tube and suitably screwed and fixing in opening as per specification & drawing complete all as specified and directed.

48

-

-

... More
S&F Factory made pre laminated PVC flush type shutter as in cup board, self, etc of 18mm (+ 0.5) thickness consisting of panel of 18mm (+0.7mm) thick celluca ply, of denstity 600 Kg per cum manufactured by ISO-9000 certified company, using for shutter celluca ply 18mm thick and fixed with frame, all four edges of shutters, using 13/6 size self tapping steel screws. The thickness of shutter is edges painted by matching colour of PVC lining of prelam coloured PVC sheet using etc complete all as specified,as per manufactuer's instruction and as directed.

14.25

-

-

... More
S&F Butt hinges, medium weight, ISI Marked ,cold rolled mild steel, size of hinges 100mm complete all as specified and as directed by Engineer - in -Charge.Make:- Classic / Hardwyn or equivalent.

30

-

-

... More
S&F 125 mm long, anodised aluminium, barrel tower bolts of extruded section ISI marked complete all as specified and directed. Make:- Classic / Hardwyn or equivalent.

20

-

-

... More
S&F 125 mm size anodised aluminium handles, cast type, ISI marked complete all as specified and directed.Make:- Classic / Hardwyn or equivalent.

20

-

-

... More
Hacking out old broken glass (any thickness, size, quality or description) from wooden frame including taking out old wooden beads complete all as specified and directed.

8

-

-

... More
S&F Sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden beads in square n.exc 0.5 Sqm in each pane etc complete all as specified and as directed.

5

-

-

... More
S&F figured glass 3.00mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane,etc complete all as specified and as directed.

3

-

-

... More
S&F in repairs galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples and wooden beads complete all as specified and as directed.

5

-

-

... More
M&L for preparation of new surfaces of wood and wood based materials of any description not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of pink primer all as specified and as directed.

30

-

-

... More
M&L for taking down of existing sunken slab treatment form the sunken portion and cleaning the surfaces by washing down with water and rubbish off the premises. (a) Cleaning and filling cracks with sealing compound, brushing neat with neat cement slurry @ 3.00 kg/ sqm and grouting in 25 mm thick plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) over sunken slab portion and finishing the top surfaces even and smooth without using extra cement . (b) M&L for two coats of acrylic cementitious water proofing coating (Dr Fixit pidifin 2K manufactured by M/s Pidilite industries Ltd or equivalent make as approved by GE) and followed by a overlay protective 15 mm thick screed/ rendering in CM 1:3 along with liquid water proofing at appropriate ratio of approved make on top surfaces of sunken slab after preparations as mentioned above. Method of application for acrylic cementitious water proofing coating is followed as per manufacturers instructions.

5

-

-

... More
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc. and applying cement slurry @ 3kg/Sqm (ii) Screed bed or bedding layer of mortar 15 mm thick in CM (1:4) for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items) (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied by torch application over bituminous primer as specified. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm. (NOTE:- The work of water proofing treatment shall be got executed through expert team of manufacturers or authorised applicator of manufacturer Contractor shall submit documentary evidence in support of applicator engaged for approval of GE.)

200

-

-

... More
S&F in repair 15 mm bore pillar taps fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. Make:- Jaquar / Prayag / Hindware.

10

-

-

... More
S&F in repair 15 mm bore brass chromium plated wall mixer with telephonic shower, complete all as specified and directed. Make : Jaquar Cat part No CON 217KN wall mixer, HSH 1929 (Shower) SHA 571(tube) Marc cat No. ES 517A(wall mixer) ES 531 (shower)/Pearl ARI-014 (wall mixer) HS 470 (Shower with tube)

1

-

-

... More
S&F in repair 15 mm bore brass chromium plated wall mixer (3 in 1) complete all as specified and directed. Make: Jaquar Model No CON 281KN, HSH 1929 & OHS 1989/ Marc ES547A & ES 531 (Telephone shower) ES 549 (shower) ES 536 (Shower)/Pearl ARI 016 (wall mixer) HS 470 (hand shower with tube) SHA 512 (Arm) SHP 525 (OH shower)

3

-

-

... More
S&F in repair 15 mm bore CP central hole basin mixer fancy type complete all as specified and directed. Make : Jaquar Model No. 167KNB, Mark: ESSCO ES-516/ Pearl ARI 013.

3

-

-

... More
S&F in repair 15 mm bore angle cock, brass chromium plated, fancy type with round headed knob, suitable for 15mm bore iron pipe complete all as specified. Make: Jaquar CON 059KN/Marc ESSCO/ES 526/Pearl ARI 004.

10

-

-

... More
S&F in repair Bib tap of 15mm dia in PTMT of any colour high pressure screwed for iron pipe and fixed. (Minimum weight 90 gms) complete all as specified and as directed.Make:- Prayag / Parryware / Sona

30

-

-

... More
S&F in repair Health Faucet with 1 mtr metalic expandable tube & hook complete all as specified and directed. Make : Jaquar model No. ALDCHR 585/ Prayag model No BEA 41/Pearl HF-133, HF 134.

7

-

-

... More
S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed.

6

-

-

... More
S&F in repair shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and as directed. Make:- Prayag / Parryware / Sona

10

-

-

... More
S&F in repair for PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.Make:- Prayag / Parryware / Sona

20

-

-

... More
S&F in repair 32 mm bore PTMT waste pipe for wash hand basin complete all as specified and directed.

38

-

-

... More
S&F in repair for grating doom 100mm dia of PTMT (minimum weight 25gms) complete all as specified and directed.Make:- Prayag / Parryware / Sona

10

-

-

... More
Dismantling of plain or corrugated steel /AC sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and directed.

320

-

-

... More
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed

270

-

-

... More
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed

50

-

-

... More
Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and refixing in position of capacity exc 500 litres & not exc 1000 litres with polythelene float and fly nut complete screwed down for iron pipe of 20 mm dia all as specified and directed.

40

-

-

... More
M&L for preparation old or previously decorated plastered surfaces of wall and applying one coat of cement base paint including necessary preparation etc complete all as specified and as directed.

2000

-

-

... More
M&L for preparation of old or previously treated wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint including necessary preparation etc complete all as specified and as directed.

400

-

-

... More
M&L for preparation of old or previously treated steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint including necessary preparation etc complete all as specified and as directed.

170

-

-

... More
M&L for applying wall care putty chalk whitening 2 to 3 mm thick and rubbing with sand paper to make the surface smooth and even etc complete all as specified and as directed.

2500

-

-

... More
M&L for preparation of old or previously decorated plastered surfaces of ceiling including cornices, plasters etc and applying one coat of white wash including necessary preparation etc complete all as specified and as directed.

500

-

-

... More
M&L for preparation of old or previously decorated plastered surfaces of wall and applying one coat of acrylic distemper including necessary preparation etc complete all as specified and as directed.

3050

-

-

... More
Excavation in trenches n. exc. 1.5 m wide and n. exc. 1.5 m depth and getting out in soft/ loose soil for foundation etc. complete all as specified and directed.

5

-

-

... More
Excavation over areas n. exc. 1.5 m depth and getting out in soft/ loose soil for foundation etc.complete all as specified and directed.

5

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25cm in soft/loose soil complete all as specified and directed.

2

-

-

... More
Removing excavated soils to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.

8

-

-

... More
Demolition and breaking up of drain pipes 200 mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.

10

-

-

... More
Demolition and breaking up of drain pipes 150 mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.

20

-

-

... More
Demolition and breaking up of drain pipes 100 mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.

50

-

-

... More
M&L for PVC (SWR) pipe single socketed 180 mm dia in any length with rubber ring joints laid in trenches including testing etc complete all as specified and directed.

10

-

-

... More
M&L for PVC (SWR) pipe single socketed 160 mm dia in any length with rubber ring joints laid in trenches including testing etc complete all as specified and directed.

20

-

-

... More
M&L for PVC (SWR) pipe single socketed 110 mm dia in any length with rubber ring joints laid in trenches including testing etc complete all as specified and directed.

50

-

-

... More
M&L for RCC pipes, class NP-2 of 200mm bore laid and jointed complete with collars complete all as specified and as directed

4

-

-

... More
M&L for RCC pipes, class NP-2 of 150mm bore laid and jointed complete with collars complete all as specified and as directed

8

-

-

... More
M&L for RCC pipes, class NP-2 of 100mm bore laid and jointed complete with collars complete all as specified and as directed

20

-

-

... More
Dismantling of cast iron or reinforced concrete drain pipes 100/75 mm, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.

10

-

-

... More
S&F cast iron soil, waste and vent sand cast pipes of 100 mm bore in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.

5

-

-

... More
S&F cast iron soil, waste and vent sand cast pipes of 100 mm bore in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed.

5

-

-

... More
S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.

25

-

-

... More
S&F in repair PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.

10

-

-

... More
S&F in repair PVC (SWR) 110mm dia branch piece, (Single Y) equal or unequal complete all as specified and as directed.

5

-

-

... More
S&F in repair PVC (SWR) 110mm dia branch piece with access door, (Single Y) equal or unequal complete all as specified and as directed.

5

-

-

... More
S&F in repairs PVC (SWR) bend of any radius 110mm bore complete all as specified and as directed.

5

-

-

... More
S&F in repairs PVC (SWR) bend with access door of any radius 110mm bore complete all as specified and as directed.

5

-

-

... More
S&F in repairs PVC (SWR) bend of any radius 75mm bore complete all as specified and as directed.

5

-

-

... More
S&F in repair PVC (SWR) 110mm dia in junction single with access door, (Single T) equal or unequal complete all as specified and as directed.

5

-

-

... More
S&F in repair PVC (SWR) 75mm dia in junction single with access door, (Single T) equal or unequal complete all as specified and as directed.

5

-

-

... More
S&F in repair PVC (SWR) vent cowl 110mm dia complete all as specified and as directed.

5

-

-

... More
S&F in repair PVC (SWR) vent cowl 75mm dia complete all as specified and as directed.

5

-

-

... More
S&F in repair PVC (SWR) reducer 110mm dia complete all as specified and as directed.

5

-

-

... More
M&L for concrete bed in cement concrete (1:3:6) type C-2 to drain pipes of 200mm bore including packing under and haunching against the sides of pipes after they are laid and tested; complete all as specified and as directed

10

-

-

... More
M&L for concrete bed in cement concrete (1:3:6) type C-2 to drain pipes of 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested; complete all as specified and as directed

20

-

-

... More
M&L for concrete bed in cement concrete (1:3:6) type C-2 to drain pipes of 100mm bore including packing under and haunching against the sides of pipes after they are laid and tested; complete all as specified and as directed

50

-

-

... More
S&F stack clamps made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm dia pipe complete all as specified and as directed

10

-

-

... More
All as per item no. 86.00 here in above but for 75 mm dia pipe complete all as specified and as directed

5

-

-

... More
Cleaning of SWG Pipe 100/150/200 mm internal dia of depth upto 1 m by rodding or by using pressure pump completely including man holes and removal of sludge to a distance exc 1.5 Km and n.exc 5 Km out side of MOD land complete all as specified & directed by Engineer-in-Charge.

150

-

-

... More
Dewatering of soak well or sewage pit of any dia and depth manually or by using mechanical pump and removal of sludge if any to a distance exc 1.5 Km but not exc 5 Km out side of MOD land complete as specified & directed by Engineer-in-Charge.

5

-

-

... More
Cleaning of septic tank of any size capacity by removing sludge in semi solid state or liquid state by manually or by mechanical pressure pump including removal of sludge to a distance exc 1.5 Km but n.exc 5 Km out of MOD land complete all as specified & directed by Engineer-in-Charge. (Note:- Measurements will be taken only after dewatering of the septic tank).

6

-

-

... More
Cleaning of manholes not exceeding 1.5m depth and removing the sludge and burying the waste material in borrow pits. Note:- (Cost of the borrowpit shall be deemed to be included in the quoted rates of this item)

40

-

-

... More
Cleaning of CI/RCC/PVC pipes of any dia from first floor to ground floor up to trap and 1st manhole along the wall, floor, including rodding and removing waste material to a distance not exc 50 mtr etc complete all as specified and as directed.

30

-

-

... More
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-l smooth finished, and reforming benching as required for 100 mm internal dia of pipe complete all as specified and as directed

10

-

-

... More
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-l smooth finished, and reforming benching as required for 150 mm internal dia of pipe complete all as specified and as directed

3

-

-

... More
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.

1

-

-

... More
M&L for precast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slabs, shelves and similar articles set in cment sand mortar (1:6) including necessary form work complete all as specified and directed.

0.5

-

-

... More
M&L for RCC (nominal mix) (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, deck slabs and in shelves etc complete all as specified and directed.

0.5

-

-

... More
M&L for form work to sides and soffits of suspended slab such as roof slabs, deck slabs and similar work, vertical or to batter, n. exc. 200 mm thick, rough finished flat surfaces complete all as specified and directed.

10

-

-

... More
M&L for Mild steel TMT deformed bars, 10 mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to Fe 500D complete all as specified and directed.

150

-

-

... More
Demolition of brickwork or stone/boulder masonry, precast cement concrete block walling in any position, built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.

4

-

-

... More
M&L for precast cement concrete (1:3:6) type C1 (using 20mm graded agg) solid block masonry exc 10cm in width or girth and setting in CM (1:6) complete all as specified and directed.

3

-

-

... More
M&L for precast cement concrete (1:3:6) type C1 (Using 20mm graded agg) solid building blocks or slabs 10cm thick (with plain or interlocking joints) setting in cement sand mortar 1:4 complete all as specified and directed.

8

-

-

... More
Demolition of PCC of any description and in any position not otherwise specifically provided for complete all as specified and as directed.

1.5

-

-

... More
M&L for PCC type B1 (1:2:4) (using 20mm graded stone aggregate) as in surface channels and drains etc. finishing surface even and smooth without using extra cement including form work complete all as specified and as directed.

0.5

-

-

... More
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.

30

-

-

... More
Add or deduct for each 25mm girth or part thereof over or under 30cm complete all as specified and directed

30

-

-

... More
M&L for Construction of PCC block masonary Soakage wells for 50 users , excavation in any type of soil, foundation in PCC 1:3:6,type C-2 using 40 mm graded stone aggregate, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in cement sand mortar (1:4) , RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8M dia x 3.0M effective depth complete all as specified and as shown in Drg No. TD/SZ/502 / Sheet no. 1/1 and as directed. Note:- Rate quoted against ibid item shall be deemed to be included for all types of required works such as earthwork, PCC block walling etc)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.