Indian Oil Corporation Limited Tender

View complete overview of Meghalaya IOCL Tender

Indian Oil Corporation Limited - IOCL Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date31 Dec 2022
Closing Date12 Jan 2023
Tender Amount₹ 1,78,95,280 
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
CONSTRUCTION OF LGSF SALES BUILDING :

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600

-

-

-

... More
i) All kinds of Soil

170

-

253.1

... More
Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil

45

-

128.75

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m

120

-

312.8

... More
Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.

-

-

-

... More
i) Local Fine Sand within grading zone IV

30

-

2003.1

... More
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil

9

-

615.15

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth

42

-

839.75

... More
Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:

-

-

-

... More
iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)

2

-

9072.95

... More
v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm)

2

-

8417.9

... More
viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm)

6

-

7792.9

... More
Centering and shuttering including strutting, propping etc. and removal of form work for:

-

-

-

... More
i) Foundations,footings,bases of column

15

-

379.3

... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level

-

-

-

... More
ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm

15

-

10303.6

... More
Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement :

-

-

-

... More
ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm

16

-

12546.65

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20 mm nominal size)

20

-

12687.85

... More
Providing and laying RCC work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).

1

-

11453.6

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
i) Foundations,footings,bases of columns, etc. for mass concrete

15

-

379.3

... More
Sales Building 7.5M X 4.8M_Opt 1 (GF)

1

-

1570745.46

... More
CONST. OF BOX CULVERT WITH OPEN DRAIN:

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600

-

-

-

... More
i) All kinds of Soil

30

-

253.1

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth

20

-

839.75

... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level

-

-

-

... More
ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm

14

-

10303.6

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
i) Foundations,footings,bases of columns, etc. for mass concrete

52

-

379.3

... More
Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels

-

-

-

... More
ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786

1500

-

133.75

... More
Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth

-

-

-

... More
ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH

12

-

8202.15

... More
Structural steel work in built up sections/ framed work in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting,hoisting,fixing in position & applying a priming coat of approved steel primer etc. as required.

2800

-

175.3

... More
Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc.

-

-

-

... More
i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand)

30

-

311.75

... More
Providing Neat cement punning

30

-

83.55

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes.

-

-

-

... More
ii) 110 mm diameter

10

-

393.9

... More
CONSTRUCTION OF DRIVEWAY, APPROACH & BUFFER STRIP

-

-

-

... More
Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge.

-

-

-

... More
i) With material confirming to grade-I (size 75 mm to .075 mm) having CBR value - 30, Thickness as desired

289.78

-

3274.45

... More
Supply and laying of water bound macadam of 100 mm consolidated thickness for subbase with 90 to 45 mm stone aggregate,11.2mm size screenings, chippings of stone and murrum spreading, watering and consolidating in camber with power roller complete as/specifications.

865

-

410.4

... More
Supply and laying of water bound macadam in layers, each of 75 mm thick (consolidated) with 63 mm to 45 mm stone aggregate. Each layer shall be consolidated by power roller after watering, spreading chippings of stone and murrum complete as per specifications. Item includes supply of murrum 6 mm thick, watering and rolling with power roller complete with preparation of surface. Rate per Layer

1730

-

324.1

... More
Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:

-

-

-

... More
viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm)

5

-

7792.9

... More
Providing & laying factory made reflective type Lacquered finish Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL's specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. (Payment for provision of edge restraints shall be made separately)

-

-

-

... More
ii) M40 grade 80 mm thick reflective type Lacquered finish

865

-

1519.7

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600

-

-

-

... More
i) All kinds of Soil

10

-

253.1

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth

30

-

839.75

... More
Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:

-

-

-

... More
iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)

1

-

9072.95

... More
Centering and shuttering including strutting, propping etc. and removal of form work for:

-

-

-

... More
i) Foundations,footings,bases of column

2

-

379.3

... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level

-

-

-

... More
ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm

18

-

10303.6

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
i) Foundations,footings,bases of columns, etc. for mass concrete

40

-

379.3

... More
Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels

-

-

-

... More
ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786

1100

-

133.75

... More
Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth

-

-

-

... More
ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH

8

-

8202.15

... More
Providing and laying cement plaster on surfaces with fine sand including curing etc.

-

-

-

... More
ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)

20

-

347.4

... More
Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/perlite respectively conforming to IS:2547 (Part - I & II), applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :

20

-

79.4

... More
Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete

20

-

264

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.

20

-

235.8

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement:3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment) (Precast C.C. kerb stone shall be approved by Engineer-in-charge.

3

-

10610.75

... More
CONSTRUCTION OF CANOPY SIZE 15.2M X 11M

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600

-

-

-

... More
i) All kinds of Soil

55

-

253.1

... More
Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.

-

-

-

... More
i) Local Fine Sand within grading zone IV

25

-

2003.1

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth

16

-

839.75

... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level

-

-

-

... More
ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm

9

-

10303.6

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
i) Foundations,footings,bases of columns, etc. for mass concrete

45

-

379.3

... More
Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels

-

-

-

... More
ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786

1200

-

133.75

... More
Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge :

-

-

-

... More
v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate

32

-

855.1

... More
Constructing masonry Chamber 60x60x75 cm,inside in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valves etc, with CI surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5

4

-

12445

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty

-

-

-

... More
ii) 150 mm dia. R.C.C. pipe

20

-

607.45

... More
iv) 300 mm dia. R.C.C. pipe

40

-

1111.2

... More
Excavating trenches of required width for pipes, cables etc including excavation for sockets & dressing of sides, ramming of bottoms,depth upto 1.5m including taking out excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing surplus excavated soil as directed, within or outside site at unobjectionable place in all kinds of soil

-

-

-

... More
iv) Pipes, Cable etc. 80mm 300m dia

60

-

514.15

... More
Providing and fixing  Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge.

-

-

-

... More
ii) Plain Sheet for Ridges (500 - 600mm).

15.2

-

555.1

... More
iii) Plain sheet for Flashings/ Aprons (Upto 600 mm)

52.4

-

508.6

... More
iv) Plain Sheet for Gutter (600 mm over all girth)

15.2

-

1368.1

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes.

-

-

-

... More
ii) 110 mm diameter

32

-

393.9

... More
Providing & fixing BARE Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of bare metal thickness 0.55 mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, Sheet shall have protective guard film of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m or as desired by Engineer-in-charge.

167.2

-

1697.1

... More
Providing and fixing  150F/200F flush panel,(pre-coated steel) False Ceiling made of  Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa & 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of  thickness of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.

167.2

-

1509.45

... More
Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:

10000

-

160.35

... More
CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items

-

-

-

... More
xxiv) 3 Core x 2.5 sq. mm Copper Cable XLPE

360

-

226.25

... More
CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.

-

-

-

... More
vii) 3 Core x 2.5 sq. mm

24

-

571.45

... More
Supply & Fixing of Weatherproof (IP-65) Thermoplastic Cable Junction Box with terminal block fitted inside the box suitable for following cable sizes.

-

-

-

... More
i) for 2.5 sq.mm. cable entry size with 9 terminals

8

-

2496.6

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material outside premises at an unobjectionable place as per direction of Engineer-in-charge.

-

-

-

... More
i) 1:3:6 or richer mix (i/c equivalent design mix)

4

-

2472.5

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars & disposal of unserviceable material outside site to an unobjectionable place as/ direction of Engineer-in-charge

2

-

3607.05

... More
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.

4

-

1166.7

... More
Demolishing brick work manually/mechanical means including stacking of serviceable material & disposal of unserviceable material outside premises at an unobjectionable place as / direction of Engg-in-charge

4

-

2092.25

... More
Dismantling granite slabs / granite tiles / marble slab on wall, floor, pump Island etc., stacking of the serviceable materials and disposal of damaged materials as directed by IOCL including all charges etc. complete

20

-

364.1

... More
S/F Under Canopy recess mounted Linear LED Lights

20

-

10875

... More
CONSTRUCTION OF HOARDING :

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600

-

-

-

... More
i) All kinds of Soil

6

-

253.1

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m

3

-

312.8

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth

2

-

839.75

... More
Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:

-

-

-

... More
ii) 1:1½:3(1 Cement :1½ Coarse Sand: 2 Graded stone aggregate of 20mm)

3

-

9588.45

... More
Providing and laying cement plaster on surfaces with fine sand including curing etc.

-

-

-

... More
ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)

3

-

347.4

... More
Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:

2000

-

160.35

... More
Painting on G.S. sheet with synthetic enamel paint of approved brand & manufacture of required colour to give an even shade, 2 or more coats,including a coat of approved steel primer but excluding a coat of mordant solution

105

-

185.05

... More
Centering and shuttering including strutting, propping etc. and removal of form work for:

-

-

-

... More
i) Foundations,footings,bases of column

17

-

379.3

... More
Supply and fixing of 30 W LED (Light Emitting Diode) light fixture with fittings and accessories for hoarding light purposes having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff = 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.

10

-

1651.15

... More
CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.

-

-

-

... More
vi) 3 Core x 1.5 sq. mm.

4

-

532.4

... More
vii) 3 Core x 2.5 sq. mm

4

-

571.45

... More
CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items

-

-

-

... More
iv) 3 Core x 2.5 sq. mm Copper Cable FRLS

60

-

234.4

... More
i) 2 Core x 1.5 sq. mm. (copper)

15

-

154.5

... More
Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following :

-

-

-

... More
v) 25 x 3 mm GI strip

20

-

92.15

... More
Supply & fixing of weatherproof 125 mm dia junction box (4 way entry) of BALIGA/CEAG-FCG/FLEXPRO/FEPL make including clamping arrangement, all complete as per specification & direction of Engineer In-charge.

1

-

2781.9

... More
TRANSPORTATION AND INSTALLATION OF TANKS :

-

-

-

... More
Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor)

-

-

-

... More
iii) 15/20 KL Tank with fittings : 0 - 30 Km

2

-

9642.75

... More
iv) 15/20 KL Tank with fittings: Add extra for each addtnl. Km above 30km

800

-

222.55

... More
Installation of supplied 20 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gasket for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete.

-

-

-

... More
iv) In earth pit with RCC matt raft as per standard Drg. ENG/314 (with earth filling)

2

-

193392.3

... More
Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125.

110

-

4641.05

... More
Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.

-

-

-

... More
i) Local Fine Sand within grading zone IV

32

-

2003.1

... More
Constructing masonry Chamber 60x60x75 cm,inside in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valves etc, with CI surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5

2

-

12445

... More
Supply and installation of screwed type gun metal valves as per IOC specifications: Ball Valve

-

-

-

... More
iii) S/I Screwed type GM Ball Valve of 50 mm dia

4

-

6514.55

... More
Supply & welding slip-on flanges conforming to IS2062 GrA, ANSI B16.5, Class#150 with 3 runs of weld outside and one run of weld inside the flanges as per specifications and standard Drg.enclosed herein

-

-

-

... More
iii) S/W Slipon flanges of 50 mm dia. conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein

12

-

1037.2

... More
Making flanged joints between flanges slip on, blind and flange etc. including providing/supplying 3 mm thick permanite oil gasket, nuts, bolts, bonding with 3 mm dia copper wire etc.complete as per IOCL specifications.

-

-

-

... More
i) Making Flange joint between Slip on,blind and flange etc.of 100mm dia. including gasket, nuts, bolts,3mm dia copper wire bonding

6

-

834.1

... More
Supplying and installation of the following threaded coupling

-

-

-

... More
i) 80 mm dia Aluminium camlock coupling - Male only

2

-

1246.15

... More
Supply and installation of ‘U’ type CS bend on the vent pipes including painting as per specifications and supplying and brazing wire mesh of 11 mesh per linear centi-meter of non-corrosive metal in two layers on both ends.

-

-

-

... More
i) Supply & installation of U type CS bend on vent pipe of 80 mm dia

1

-

2489.75

... More
Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loaded type or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Cover and adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval.

1

-

8042.05

... More
Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping

-

-

-

... More
ii) S/L Welded U/G HD MS Pipes of 80mm dia with fittings,doping

10

-

2182.6

... More
iii) S/L Welded U/G HD MS Pipes of 50mm dia with fittings,doping

12

-

1377.6

... More
iv) S/L Welded U/G HD MS Pipes of 40mm dia with fittings,doping

18

-

1112.7

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600

-

-

-

... More
i) All kinds of Soil

25

-

253.1

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth

10

-

839.75

... More
Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:

-

-

-

... More
v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm)

3

-

8417.9

... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level

-

-

-

... More
ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm

2

-

10303.6

... More
Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels

-

-

-

... More
ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786

200

-

133.75

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
i) Foundations,footings,bases of columns, etc. for mass concrete

25

-

379.3

... More
Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth

-

-

-

... More
ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH

8

-

8202.15

... More
Providing and laying cement plaster on surfaces with fine sand including curing etc.

-

-

-

... More
ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)

80

-

347.4

... More
Providing Neat cement punning

18

-

83.55

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.

75

-

235.8

... More
Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete

75

-

264

... More
Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:

900

-

160.35

... More
CONST.OF PUMP ISLAND & DU INSTALLATION:

-

-

-

... More
Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor)

-

-

-

... More
xi) MPD/MPP pumps upto 2 nos., 0-30 Km

2

-

3560.4

... More
xii) MPD/MPP pumps upto 2 nos., Add extra for every additional Km above 30km

700

-

59.35

... More
vii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos,0-30 Km

2

-

2670.3

... More
viii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos, Add extra for every additional Km above 30km

700

-

59.35

... More
Installation of supplied Multi Product Pumps / Dispensers on pump island as per manufacturers installation manual, drawings, including supplying, providing necessary frame of ISMC 100, foundation bolts, supplying and filling required quantity of dry sand in pit(s) below the pump

-

-

-

... More
i) 2 product - 4 nozzle MPPs/MPDs

2

-

16727.9

... More
Installation of Corporation supplied Standard Submersible Turbine Pump on the existing Manhole Cover as per drawing and direction of Engineer in Charge

2

-

2355.2

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600

-

-

-

... More
i) All kinds of Soil

25

-

253.1

... More
Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.

-

-

-

... More
i) Local Fine Sand within grading zone IV

15

-

2003.1

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth

14

-

839.75

... More
Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:

-

-

-

... More
iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)

1

-

9072.95

... More
v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm)

2

-

8417.9

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
i) Foundations,footings,bases of columns, etc. for mass concrete

5

-

379.3

... More
Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth

-

-

-

... More
ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH

8

-

8202.15

... More
viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH

3

-

1032.15

... More
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels.

-

-

-

... More
iv) Granite of any colour and shade having Area of slab over 0.50 sqm

12

-

5451.5

... More
Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete.

9

-

4305.1

... More
CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items

-

-

-

... More
iii) 3 Core x 1.5 sq. mm. (copper)

150

-

178.4

... More
iv) 3 Core x 2.5 sq. mm Copper Cable FRLS

120

-

234.4

... More
CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.

-

-

-

... More
vi) 3 Core x 1.5 sq. mm.

8

-

532.4

... More
vii) 3 Core x 2.5 sq. mm

6

-

571.45

... More
Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make

-

-

-

... More
ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire

20

-

311

... More
CONSTANT VOLTAGE TRANSFORMER Supplying, installation, testing and commissioning of single phase, air cooled constant voltage transformer of approved make having input voltage range of 180-260V and output voltage of 220/230V with sine wave output wave form and having automatic current limiting and short circuit protection including all accessories complete (for displays) for the following VA ratings.

-

-

-

... More
iii) 500VA CVT

2

-

8566.5

... More
PROVIDING INTERNAL WIRING

-

-

-

... More
ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.

2

-

1336.95

... More
Chemical Earthing with Copper Bonded Rod suitable for current carrying capacity of 15kA for 1 second - Supply of chemical earthing Cu Bonded High Tensile Low Carbon Steel Rod of dia not less than 17mm electrode complying to UL 467 Requirements & suitable for current carrying capacity of 15kA for 1 second, exothermic welded & 3Mtr long

2

-

26652.45

... More
Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following :

-

-

-

... More
i) 50 x 10mm G.I. Strip

180

-

468.4

... More
ii) 32 x 6 mm G.I.strip

60

-

171.7

... More
v) 25 x 3 mm GI strip

140

-

92.15

... More
PROVISION OF ELECTRIC PANEL & ALLIED ELECTRICAL WORKS

-

-

-

... More
PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032.

-

-

-

... More
Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL.

1

-

248799.6

... More
CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items

-

-

-

... More
xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS

80

-

570.5

... More
PROVIDING INTERNAL WIRING

-

-

-

... More
i) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.

30

-

1312.05

... More
Providing following point wiring with standard wire/ cable, plug, fittings, with suitable sockets, suitable GI box with front plate etc. complete, to include circuits from distribution boards to individual point boards, suitable PVC casing capping and required accessories pulling of wires, etc. complete.

-

-

-

... More
i) Supplying and drawing following 2 pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.

10

-

42.95

... More
Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make

-

-

-

... More
i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire

35

-

263.55

... More
ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire

40

-

311

... More
iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire

40

-

377.8

... More
iv) 2 x 6 sq mm + 1 x 6 sq mm earth wire

40

-

496.5

... More
SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge.

-

-

-

... More
iii) 4 module frame

6

-

387.95

... More
viii) 15 A Modular switch

20

-

446.85

... More
xi) 2 Pin Telephone Modular Socket

2

-

437.95

... More
xii) Fan Regulator of stepped modular type

2

-

754.45

... More
Supply & fixing of 30mA RCCB of approved Make of following ratings:

-

-

-

... More
v) 4 poles, 63A

1

-

3248.5

... More
Supplying & fixing of approved make 4 pole change over switch in steel sheet enclosure with side handle operation onload type grouting in C.C. Complete as per direction of Engineer-In-Charge.

-

-

-

... More
iii) 100 Amps., 4 Pole

1

-

6328.55

... More
Supply and Installation of Flame Proof ESD Push Button

2

-

2544.7

... More
MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusive of MCB, Three Phase, as per Approved Make of following types: (MCB - 10KA Breaking Capacity)

-

-

-

... More
i) S/E 4 way DB with 63A FP RCBO, 300 mA sensitivity as incoming - 1No.& 6 to 16A SP as outgoing - 4 Nos. for each phase.

1

-

19796.4

... More
Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watt, having IP20 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports & reference/batch nos of LEDs & fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc.

8

-

252.95

... More
Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP65 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc.

6

-

326.35

... More
CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type:

-

-

-

... More
iii) 1200 mm sweep

2

-

3418.75

... More
EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does not include making suitable cut out in the wall for fixing the fan).

-

-

-

... More
ii) 9" dia light duty, make Khaitan or equivalent

2

-

2562.9

... More
Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works:

-

-

-

... More
ii) Horizontal air compressor Assembly of 3 HP (160-220 LITRES) including civil works

1

-

105294.25

... More
Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.)

1

-

40112.35

... More
Supplying and fixing of MV Lightining Arrestor horn gap type as required

1

-

308.75

... More
Supply of Galvanised Fire buckets of 9 litre capacity, painted white inside and red outside with letters 'fire' in black, conforming to IS 2546-1974.

8

-

561

... More
Supplying Fire bucket stand- 4 buckets hanging arrangement 1 meter height, made of 50x50x6mm angle frame, painted with 2 coats of primer and 2 coats of Red, synthetic enamel paint.

2

-

3115.35

... More
Supplying and fixing of 4.5kg CO2 fire extinguisher of approved make Conforming to IS 15683, portable high pressure type. Body seamless Manganese Steel, ISI marked conforming to IS 7285, discharge valve conforming to IS 324,polyethylene flat discharge horn with diffuser,1m wire braded rubber hose, powder coated wall mounting mild steel bracket,stainless steel safety pin of SS 316 grade, CO2 gas with 99.5% purity. Extinguisher shall have anti corrosive treatment of phosphating by hot dipping process to thickness not less than 0.012mm both internally and externally. Epoxy polyester powder coating of minimum 50 micron to all metallic external parts with two bands of yellow colored fluorescent adhesive tape of minimum 20mm thickness of body. Finish of the paint to be PO red as per shade 538 of IS:5

1

-

6230.7

... More
Supplying and fixing of 9kg DCP portable,cartridge type Fire extinguisher of approved make,Conforming to IS15683:2006,Body Carbon Steel as per IS:513,EDD grade with no vertical weld joint on the body Neck ring of seamless mild steel tube conforming to IS 1239 part-1, Valve assembly conforming to SS 316 grade or forged brass as per IS 6912 grade FLB, Inlet and outlet siphon tubes of SS 316 grade or of brass as per IS 407, Discharge nozzle of SS 316 grade of forged brass as per IS 6912, 500mm long discharge hose of EDPM rubber, powder coated wall mounting mild steel bracket,stainless steel safety Pin of SS 316 grade, Dry Chemical powder ( potassium bi-carbonate & Minimum 90% of the total chemical), ISI marked CO2 Gas cartridge of 200 gms, dia of the body 175mm +/- 10mm & overall height less than 650mm.Extinguisher shall have anticorrosive treatment of phosphating by hot dipping process to thickness not less than 0.012mm both internally & externally. Epoxy polyester powder coating of minimum 50 micron to all metallic external parts with two bands of yellow colored fluorescent adhesive tape of minimum 20mm thickness of body. Finish of the paint to be PO red as per shade 538 of IS:5

4

-

3426.9

... More
iii) Supply and fixing of shock treatment chart in English, Hindi & local language framed in glass framework.

1

-

928.95

... More
Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job)

2

-

2687.8

... More
Supplying & Fixing of following items for electrical safety in switch rooms/DG rooms etc

-

-

-

... More
i) Electrical insulating mats made of PVC Elastomer 3mm Thick & 1 mtr wide near swichboards, etc as per direction of Engineer In charge. Mat should conform to IS 15652 Class A - suitable for safe working voltage of upto 33 kV. Test certificate to be provided with supply. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip.

4

-

1100.2

... More
iv) 11 KV grade hand gloves, ISI mark

1

-

778.85

... More
Formation of lighting protection arrangement with supply of 1.0 M height spike and erection at top most portion of structure/building and connecting the same to earthpit by 40x6mm GI strip (excluding supply and laying of GI strip)

1

-

4640

... More
Intelligent Line Conditioner (ILC): Supply, Installation and Commissioning of IGBT based Static Voltage Stabilizer of Capacity 15kVA Three Phase with three phase surge protection device and Manual bypass switch; Voltage regulation done by High Frequency(20kHz) PWM driven IGBT.ensuring that the outpu t voltage complies with the requirements of ITIC curve for regulated voltage supply to electronic machineryby superimposing generate d wave on input wave, without any break or switching in the power path, current interruption, transition or step changingNo moving p art like Relay or Brush to be used for voltage regulation; The Architecture to be fully Solid State; The output voltage must be free of harmful all spikes and EMI/RFI noises; Full Regulation Input Voltage Range 170-290VAC L-N: 295-505VAC L-L; Full Regulation Outpu t Voltage 230VAC L-N ±1%: 400VAC L-L ±1%; Relaxed Regulation Input Voltage Range 140-300VAC L-N: 245-515VAC L-L; Relaxed Regulation Output Voltage 200-240VAC L-N; Operation Frequency 47-53Hz; Correction Speed at least 6000V/s; Efficiency at least 96% even at parti al load; MCB at Input; Contactor at Output; Manual Bypass Switch; Overload, Short- Circuit, Double Phase, Overvoltage (at 300VAC L-N ), Undervoltage (at 140VAC L-N) Protections; Class II Surge Protection on all three phases independently, for at least 6kV, 8x20𝜇s waveform; Ingress Protection at least IP20; Class H Insulation for Galvanic Components; Digital Annunciation for status; Operating T emperature 0-60° C

1

-

65083.49

... More
SUPPLY AND INSTALLATION OF YARD LIGHTS :

-

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty

-

-

-

... More
ii) 150 mm dia. R.C.C. pipe

80

-

607.45

... More
Excavating trenches of required width for pipes, cables etc including excavation for sockets & dressing of sides, ramming of bottoms,depth upto 1.5m including taking out excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing surplus excavated soil as directed, within or outside site at unobjectionable place in all kinds of soil

-

-

-

... More
iv) Pipes, Cable etc. 80mm 300m dia

80

-

514.15

... More
Constructing masonry Chamber 60x60x75 cm,inside in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valves etc, with CI surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5

6

-

12445

... More
CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items

-

-

-

... More
iv) 3 Core x 2.5 sq. mm Copper Cable FRLS

350

-

234.4

... More
xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS

60

-

570.5

... More
CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.

-

-

-

... More
vii) 3 Core x 2.5 sq. mm

8

-

571.45

... More
Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following :

-

-

-

... More
v) 25 x 3 mm GI strip

40

-

92.15

... More
OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) :

-

-

-

... More
iii) S/E of 5 Meter high galvanised Octagonal pole with top 60mm(A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides)

7

-

12137.3

... More
Supply, fitting, fixing of arm bracket, tubular type, 38mm/50mm dia on pole including painting, all complete.

-

-

-

... More
ii) S/E Arm " Y " bracket 38/50mm dia on pole, as per specifications and direction of Engineer in charge

2

-

2187.4

... More
Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge.

-

-

-

... More
i) "Y" Pole

2

-

2863.8

... More
ii) "L" Pole

5

-

2863.8

... More
Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff = 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.

11

-

6484.4

... More
i) All kinds of Soil

12

-

253.1

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth

6

-

839.75

... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level

-

-

-

... More
ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm

5

-

10303.6

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
i) Foundations,footings,bases of columns, etc. for mass concrete

32

-

379.3

... More
Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels

-

-

-

... More
ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786

350

-

133.75

... More
CONSTRUCTION OF MONOLITH FOUNDATION

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600

-

-

-

... More
i) All kinds of Soil

12

-

253.1

... More
Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil

6

-

128.75

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m

17

-

312.8

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth

10

-

839.75

... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level

-

-

-

... More
ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm

5

-

10303.6

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
i) Foundations,footings,bases of columns, etc. for mass concrete

17

-

379.3

... More
Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels

-

-

-

... More
ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786

320

-

133.75

... More
Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth

-

-

-

... More
viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH

2

-

1032.15

... More
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels.

-

-

-

... More
iii) Granite of any colour and shade having Area of slab upto 0.50 sqm

4

-

5764.35

... More
Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete.

6

-

4305.1

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes.

-

-

-

... More
ii) 110 mm diameter

8

-

393.9

... More
Providing and laying cement plaster on surfaces with fine sand including curing etc.

-

-

-

... More
i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)

4

-

363.2

... More
Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge :

-

-

-

... More
v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate

16

-

855.1

... More
CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items

-

-

-

... More
iv) 3 Core x 2.5 sq. mm Copper Cable FRLS

72

-

234.4

... More
CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items

-

-

-

... More
vii) 3 Core x 2.5 sq. mm

2

-

571.45

... More
Supply & fixing of weatherproof 125 mm dia junction box (4 way entry) of BALIGA/CEAG-FCG/FLEXPRO/FEPL make including clamping arrangement, all complete as per specification & direction of Engineer In-charge.

1

-

2781.9

... More
STANDARD DISPLAY BOARD-EGRESS SIDE

-

-

-

... More
i) All kinds of Soil

2.58

-

253.1

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m

0.51

-

312.8

... More
i) M-15 grade plain cement concrete (cement content considered @ 240 kg/cum

1.22

-

10070.25

... More
i) RCC 1 Cement :1 Coarse Sand: 2 Graded Stone Aggregate 20mm

0.86

-

12090.4

... More
i) Foundations,footings,bases of columns, etc. for mass concrete

6.16

-

379.3

... More
ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786

122.01

-

133.75

... More
i) 12mm dia x 300mm long with 75 mm dia x 3 mm thick plate

20

-

70

... More
iv) Granite of any colour and shade having Area of slab over 0.50 sqm

5.29

-

5451.5

... More
i) Hot finished welded type tubes

372.87

-

190.8

... More
ii) Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron)

64.36

-

782.95

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.

21.03

-

235.8

... More
iv) 3 Core x 2.5 sq. mm Copper Cable FRLS

80

-

234.4

... More
i) Pipes,cables etc. not exceeding 80mm dia

50

-

314.8

... More
vii) 3 Core x 2.5 sq. mm

4

-

571.45

... More
i) for 2.5 sq.mm. cable entry size with 9 terminals

1

-

2496.6

... More
ii) 2+8 way SPN

1

-

2910.3

... More
ii) Upto 32A DP MCB

1

-

742

... More
Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff = 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.

2

-

326.35

... More
STANDARD DISPLAY BOARD-INGRESS SIDE

-

-

-

... More
i) All kinds of Soil

1.53

-

253.1

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m

0.35

-

312.8

... More
i) M-15 grade plain cement concrete (cement content considered @ 240 kg/cum

0.69

-

10070.25

... More
i) RCC 1 Cement :1 Coarse Sand: 2 Graded Stone Aggregate 20mm

0.49

-

12090.4

... More
i) Foundations,footings,bases of columns, etc. for mass concrete

4.81

-

379.3

... More
ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786

69.21

-

133.75

... More
i) 12mm dia x 300mm long with 75 mm dia x 3 mm thick plate

12

-

70

... More
iv) Granite of any colour and shade having Area of slab over 0.50 sqm

3.15

-

5451.5

... More
i) Hot finished welded type tubes

202.19

-

190.8

... More
ii) Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron)

38.05

-

782.95

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.

10.66

-

235.8

... More
iv) 3 Core x 2.5 sq. mm Copper Cable FRLS

70

-

234.4

... More
i) Pipes,cables etc. not exceeding 80mm dia

40

-

314.8

... More
vii) 3 Core x 2.5 sq. mm

4

-

571.45

... More
i) for 2.5 sq.mm. cable entry size with 9 terminals

1

-

2496.6

... More
ii) Upto 32A DP MCB

1

-

742

... More
Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff = 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.

1

-

326.35

... More
YARD LIGHTS ADVERTISEMENT BOARD

-

-

-

... More
i) Hot finished welded type tubes

91

-

190.8

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.

4

-

235.8



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.