Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/MAINT AND CLEANING OF SEWAGE LINE, MANHOLES/SEPTIC TANK/SOAKAGE PITS AT UPPER LKG MIL STN, ENGR REGT, CENTRAL SECTOR AND KOIRENGEI
Amendment to tender documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolition of brick work built in cement mortar incl all quions, arches, pillars etc. but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and directed.

49

-

-

... More
Demolition and breaking up 110/150/200/250 mm bore drain pipes, soil , waste and pipes etc (RCC/ SWG/CI etc) of any description in trenches or floors, including connections and fittings complete all as specified and directed.

30

-

-

... More
Demolition and breaking up of 75/110mm bore PVC/CI pipes & fitted on walls complete all as specified and directed.

335

-

-

... More
Taking down of cement plaster inculding wall finishes in any description on brick or stone wall etc., incl hacking out joints for key scrubbing down with water etc. all as specified and directed

60

-

-

... More
Excavation in trenches n exc 1.5 Mtr wide and n exc 1.5 M deep and getting out in hard dense soil (including cutting of roads) for shafts, wells, man holes and for sewage lines and foundation etc n exc 10 Sqm on plan complete all as specified and directed.

40

-

-

... More
Excavating over areas, n exc .1.5 m deep and getting out soft/loose soil complete all as specified and directed.

48

-

-

... More
Excavating over areas, exc .1.5 m and n.exc 3.00 m deep and getting out soft/loose soil complete all as specified and directed.

16

-

-

... More
Returning filling in of excavated any type soil including spreading leveling watering and well ramming in layers n exc 25 cm thick complete all as specified and directed.

44

-

-

... More
Removal of surplus spoil/excavated material to a distance upto 250M and deposited, spread and leveled where directed by Engineer-in-Charge not exc 1.5 M above the starting point complete all as specified and directed.

60

-

-

... More
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in benching ,kersbs complete all as specified and directed.

1.2

-

-

... More
M&L for PCC (1:4:8) type D-2 using 40 mm graded aggregate as in foundation filling & mass concrete complete all as specified and directed.

11

-

-

... More
M&L for brick work with sub class ‘B’ modular bricks straight or curved o plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.

45

-

-

... More
Ditto all as per Sl item No. 14.00 here-in-above but except brick (NOTE: Seviceable brick obtained from demolition under Sl item No 3.00 here-in-above shall be reused under the item)

4

-

-

... More
M&L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping for manhole including slightly rounded or chamfered angles and including necessary form work finishing exposed surface complete all as specified and directed.

0.9

-

-

... More
M&L PCC 1:2:4 type B-1using 20 mm graded stone aggregate in drains and surface channels and finishing complete all as specified and directed.

1.25

-

-

... More
M&L for rendering 15mm thick on fair faces of brick work in cement mortar(1:4) using water proofing compound @2% by weight or cement as per manufacture instruction and finishing even and smooth without using extra cement all as specified. (Note: Plastering shall be carried out using Dimapur Sand. Note: WPC will be measured and paid separately)

350

-

-

... More
Supply only Integral waterproofing compound complete all as specified and directed.

70

-

-

... More
S& F reinforced concrete pipes class NP-2 laid and jointed complete with collars as directed by engineer in charge for the following dia (a) 150 mm

30

-

-

... More
M&L for concrete bed of PCC 1:4:8 type D2 using 40 mm graded stone aggregate for drain pipes bedding & hunching against the sides complete after pipes are laid, jointed and testedcomplete all as specified and directed. (a) 150 mm

30

-

-

... More
Cutting/filling into existing manholes for connecting new sewage line 225mm bore (internal dia of pipe ) incl making good to disturbed benching and haunching, plaster etc and forming new branch channel ( ½ round of ¾ section) if required in cement concrete 1:2:4 type B1 and smooth finished , reforming benching as required and as directed for internal dia for the following pipe. (Each Man hole shall be measured under this item )

10

-

-

... More
M&L for TMT bars 8 mm dia cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.

307

-

-

... More
M & L for reinforcement TMT bars 10mm dia and over cut to length, bent to shape reqd including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.

420

-

-

... More
M&L for precast RCC ( nominal mix) 1:2:4 type B1( using 20mm stone aggregate ) as in cover slab for manhole etc with plane faces complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M&L for RCC (Nominal Mix) type B0 1:2:4 (12.5mm graded stone aggregate ) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.(Sand :- Dimapur) Note :- Reinforcement and form work required shall be measured and paid seperately.

1

-

-

... More
M&L for Reinforced cement concrete ( nominal mix) type B0 (1 :2:4) (using 12.5 mm graded stone agg.) as in Slabs supported on walls,beams and columns in floors, roofs/chajja, landings, balconies, canopies, deck slabs and in shelves and the like roof complete all as specified and directed.

2.5

-

-

... More
M&L for formwork to sides and soffits of floor or roof beam etc For finished surfaces of concrete complete all as specified and directed.

6

-

-

... More
M&L for formwork to soffits of suspended slabs as roof slabs, floor slabs, landinqs, lintel / chajja and similar work not exceeding 200 mm thick for finished surfaces of concrete complete all as specified and directed.

20

-

-

... More
M&L for 50mm thick sand stone slab in as in manholes cover stone etc size not less than 0.60x 1.20 m ,set and pointed in CM 1:4 complete all as specified and directed.

10

-

-

... More
M&L for 50mm thick sand stone slab in as in GT cover stone etc size not less than 0.45x 0.45 m ,set and pointed in CM 1:4 complete all as specified and directed.

10

-

-

... More
Cleaning existing sewage (SWG,SWR,RCC Pipe line) from manholes to manhole by rodding with required equipments so as to completely removal the accumulated/deposited sludge and sediments and finally washing with clean water all as specified for size of pipe line:- (a) 100 mm dia

450

-

-

... More
(b) 150 mm dia

300

-

-

... More
(c) 200 mm dia

100

-

-

... More
Cleaning of manholes of any depth by opening including de-sludging, de- watering either by mechanical pump or manually, taking out soilids / semi solid sludge, flushing with water, removing and disposal of the sludge etc to a distance not exc 50m & buried in shallow pits with a covering of soft/loose soil of minimum 20 cm thick at an inhabitable location in the cantt area and sprinkling bleaching powder @ 1 kg per sqm complete all as specified and directed. Note:- (i) Unit rate is inclusive of supply of bleaching powder and necessary earth work. (ii) 02 Nos of labourers for cleaning of manholes/nahani trap/gully trap manually will report to AGE B/R -II complaint cell at 0845hrs daily except on holiday, failing which the recovery @ Rs. 500/- day per person will impose to the contractor as the clearing of sewage blockage is an essential work.

305

-

-

... More
Cleaning of accumulated soild/semi soild or liquid sludge from septic tanks or any size either by mechanical pump or manually and collecting the sludge so removed in a container and disposal of the same to a distance not exceeding 50m in shallow pits with a covering of loose /soft soil of minimum 20 cm thick at an inhabitable location in the Cantt area and sprinkling bleaching powder @ 1 Kg per Sqm complete all as specified and directed. Note:-Unit rate is inclusive of supply of bleaching powder and necessary earthwork.

80

-

-

... More
Operation of sewage suction machine by one skilled operator and one helper for collecting waste sewage sludge from septic tank/soak well/soak pit/manhole at various loc of LMS. The trasnportioan/towing of suction machine should be provided by the contractor and dumping of waste at approved dumping site as directed by Engineer-in-Charge. Note: (i) Sewage suction machine will be issued under Sch 'C' items. Machine shall be returned to the deptt after operation duly demand/wasted and disinfected. -cleaned / washind (ii) Towing vechicle shall be provided by the contractor and unit quoted rate shall be demmed to beinclusive for the same. (iii) Waste shall be dumped in excavated dump pits and shall be disinfected using bleaching power.

90

-

-

... More
De-sludging the solid sludge from soak well, cleaning aggregates obtained from soak well for reuse ( minimum 50% for the purpose) placing the same with new brick bats, depositing the sludge / silt in trenches with a coverage of soft/loose soil of minimum 20 cm thick at an inhabitable location in the Cantt area and sprinkling bleaching powder @ 1 Kg/ sqm complete all as specified and directed. Note:-Unit rate is inclusive of supply of bleaching powder and necessary earthwork.

20

-

-

... More
S&F PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenches or in floors of the following bore inculding cutting out wall /concrete and finishing of surface to match existing surface . (a) 75mm

50

-

-

... More
(b) 110mm

150

-

-

... More
S&F PVC (SWR) pipes single socketed in any length with rubber rings joints laid in fixed to walls including clamps of the following bore (a) 75mm

40

-

-

... More
(b) 110mm

95

-

-

... More
S&F PVC (SWR) pipe bend with accessable door of the following bore inculding cutting out wall /concrete and finishing of surface to match existing surface . (a) 75mm

6

-

-

... More
(b) 110mm

4

-

-

... More
S&F PVC (SWR) branch piece single (Y) equal or unequal bend with accessable door of the following bore inculding cutting out wall /concrete and finishing of surface to match existing surface . (a) 75mm

7

-

-

... More
(b) 110mm

7

-

-

... More
S&F PVC (SWR) junction single (single `T') equal or unequal with accessable door of the following bore inculding cutting out wall /concrete and finishing of surface to match existing surface . (a) 75mm

4

-

-

... More
(b) 110mm

6

-

-

... More
S&F PVC (SWR) vent cowl 75mm bore complete all as specified and directed.

5

-

-

... More
S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed.

4

-

-

... More
S&F PVC(SWR) P/S trap 110 mm bore inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed.

10

-

-

... More
S&F PVC(SWR) P/S trap 125 mm bore inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed.

10

-

-

... More
S&F in repairs PVC(SWR) floor trap/Gully Trap 75mm outlet dia plain with grating including jointing with solvent cement inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed.

7

-

-

... More
S&F Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls including clamps of the following bore (a) 75mm

6

-

-

... More
(b) 110mm

12

-

-

... More
S&F CI soil pipes bend with accessable door of the following bore inculding cutting out wall /concrete and finishing of surface to match existing surface . (a) 75mm

2

-

-

... More
(b) 110mm

3

-

-

... More
S&F CI soil pipes branch piece single ( equal or unequal), ordinary or inverted (Spigot or socket type) or with parallel branches , with accessable door of the following bore inculding cutting out wall /concrete and finishing of surface to match existing surface . (a) 75mm

2

-

-

... More
(b) 110mm

3

-

-

... More
S&F CI soil pipes vent cowl 110mm bore complete all as specified and directed.

2

-

-

... More
S&F CI soil pipes vent cowl 75mm bore complete all as specified and directed.

2

-

-

... More
S&F in repairs vitreous china squatting pan “Orissa pattern of size 540x440mm white, back inlet and integral foot rests (excluding flushing cistern and flush pipe) but including lime concrete bedding complete all as specified and directed.

6

-

-

... More
S & Fin repair vitreous china wash down water closet pan (pedestal pattern) white with integral foot rest with ‘P’ or ‘S’ trap (excluding flushing cistern and flush pipe) including all fitting complete all as specified and as directed.

10

-

-

... More
S&Fixed in repair EWC seat cover PVC white colour including all fitting arrangements complete all as specified and as directed.

18

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.