Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for brick work with sub class ‘B’ brick straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed.

5

-

-

... More
Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water complete all as specified and directed.

190

-

-

... More
M&L for rendering 15mm thick in CM 1:4 on on fair surfaces of brick in two separate coats (10mm thick backing coat and 5mm thick) using water proofing compound @2% by weight of cement as per manufacture instruction and finishing works/concrete surfaces finished even and smooth complete all as specified and directed. Note : (i) WPC will be measured and paid separately (ii) Rates deemed to be inclusive of scaffolding upto height 12 Mtr at reqd places. No additional payment will be made on this account.

120

-

-

... More
Supply only intergral water proofing compound complete all as specified and directed

10.22

-

-

... More
M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed.

50

-

-

... More
M & L for rendering 5mm thick on fair face of brick work or concrete surface wall or ceiling in CM 1:3 finishing even and smooth without using extra cement complete all as specified and as directed.

20

-

-

... More
M&L for preparation for new or previously untreated plastered surface of walls and applying two coats of cement base paint complete all as specified and directed.

120

-

-

... More
M&L for preparation of surfaces plastered or unplastered new surface on wall and applying two coats of oil bound distemper complete all as specified and directed.

50

-

-

... More
M&L for preparation of surfaces plastered or unplastered new surface on ceiling and applying three coats of white washing complete all as specified and directed.

20

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed

290

-

-

... More
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thick thickness below or above ground level complete all as specified and directed.

5.5

-

-

... More
M & L for Non skid coloured ceramic tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and includig 15 mm thick screed bed in CM 1:4 complete all as specified and directed

180

-

-

... More
M&L for 25mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in levelled course finish even and fair for tile finishes complete all as specified and directed by Engr in Charge.

220

-

-

... More
M & L for Non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed by Engr in Charge

40

-

-

... More
M & L for Glazed Coloured Ceramic tiles in vertical surface 350x250x7mm / 450x350x7mm thick set and joint in neat cement slury and pointed in white or colour cement to match over and including 10mm thick rendering in CM 1:4 as backing coat to receive tiles complete all as specified and directed.

60

-

-

... More
M & L for Non skid coloured ceramic tiles 7 to 8mm thick of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including rendering 10 mm thick on fair faces of brick work in CM (1:4) for receving vertical dado tiling complete all as specified and directed.

10

-

-

... More
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete all as specified and directed.

15

-

-

... More
Taking down shutters of any description exc 1 sqm and not exc 2 sqm each including easing and adjusting and also refixing builder hardware as required including renewal of unserviceable screw and necessarry materials refixing shutter in same opening complete all as specifeid and directed.

20

-

-

... More
Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm single piece extruded PVC profiles reinforced with 19 x 19mm MS square tube provided with EPDM rubber gasket weather seal through out the frame and the profile mitre cut at two corners and joined by inserting 2 nos 150mm long brackets of 15 x 15mm MS square tube inside 19 x 19mm MS square tube suitably screwed complete all as specified and as directed.

40

-

-

... More
Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes of size 15 x 15mm for top and bottom rails and 19 x 19mm for stiles, MS frame covered with 5mm thick single piece extruded PVC profile 'C' channel having a 5mm thick PVC sheet strip of 20mm width struck inside with solvent cement, forming stiles, and 5mm thick single piece extruded PVC profile for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail; panelling of 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc all as per manufacturer's instructions and drawings as shown in SSR Part-I 2009 complete all as specified and as directed.

10

-

-

... More
S&F 75mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed.

27

-

-

... More
S&F 150mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.

20

-

-

... More
S&F 150mm long alumiunium handles cast type anodised complete all as specified and directed.

19

-

-

... More
S&F 50mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed

21

-

-

... More
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.

19

-

-

... More
S&F 2nd class hard wood small fittings such as brackets of any type ,latch and hing block ,shaped door and window stops and the like including all necessary labours articles n exe 200 cu.cm each complete all as specified and directed.

30

-

-

... More
Dismantling of framed timper scantling 40 sq .cm and over in section,in any position complete all as specified and directed.

0.5

-

-

... More
Ditto all as per item No 29 here-in-above but in fillets in framed work under 40 sq.cm in section complete all as specified and directed

30

-

-

... More
M&L for second class clean sawn hard wood in scantling wrought, timber framed & fixed complete all as specified and directed.

0.5

-

-

... More
Preparation of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oil complete all as specified and directed

15

-

-

... More
S&F 18/19 mm thick block boards, grade 1 quality, exterior with decorative face veneer on both faces grade, fixed with screws to timber frame work complete all as specified and directed

10

-

-

... More
S&F 2nd class HW weather boarding, clean sawn, plainl 20mm thick or reather edged 15mm to 20mm thick and fixed with 30mm laps complete all as specified and directed

9

-

-

... More
M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer on wooden surfaces complete all as specified and directed.

18

-

-

... More
Hacking out old brocken glass (any thickness, size,quality or description) from wooden frames or steel frame, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed

30

-

-

... More
S&F sheet glass 3mm thick, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed.

30

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.

12.13

-

-

... More
M&L for MS work as in framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.

50

-

-

... More
S & F steel work in tubular or square trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to Fe 410-W (Gde-E-250 quality A) complete all as specified and as directed by the Engineer-in-Charge

400

-

-

... More
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sucnk) forming holes with any attachement Fe 410W (Gde-E-250) Quality A complete all as specified.

100

-

-

... More
S&F rolled mild steel Fe-410w (Gde-E-250) quality 'A' Roof trusses (framed) , trussed, purlins, crane gantries , rails and fastening and havy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc complete all as specified.

600

-

-

... More
All as per item No 42 here-in-before but fixing only complete all as specified and directed

62.5

-

-

... More
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.

60

-

-

... More
S&F in repair water closet (Squating pattern) of vitreous china squatting pan of "ORRISA" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) incl connection to trap and flushing pipe and anti syphon pipe etc complete incl trap set in and incl concrete bedding complete all as specified and as directed

3

-

-

... More
S&F in repair, light coloured Vitreous china wash basin, white oval shape, size 550 x 400 mm excl taps, waste chain and plug and porcelain stopper but incl brackets, waste pipe & CP waste coupling complete all as specified and as directed.

6

-

-

... More
S&F in repairs Pillar taps, 15mm dia cast copper alloy, with capstan heads, chromium plated, but fancy type screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.

10

-

-

... More
S&F in repair 10 ltrs capacity high or low level flushing cistern PVC of selected white valveless syphonoic action type inlet ball valve float and handle 10 ltrs discharge capacity complete including PVC connection and brackets complete all as specified and directed.

10

-

-

... More
S&F PVC (SWR) floor trap with grating with incl jointing to waste pipe fixed in cement concerete (1:2:4) diameter of outlet pipe 75mm complete all as specified and directed.

12

-

-

... More
S&F PVC connection 15x600mm long with PTMT nuts & bolts complete all as specified and directed.

11

-

-

... More
S & F in repairs bore bib taps, ISI marked cast copper alloy, chromium plated fancy type screwed down, screwed for iron pipe or for brass ferule for 15 mm bore dia of pipe complete all as specified and directed.

12

-

-

... More
S&F in repair fancy type Chromium plated with long shank and cup (concealed type) stop valve cost copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe 15mm bore complete all as specified and as directed.

10

-

-

... More
S&F in repairs brass chromium plated shower roses 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union any colour for fixing with 15mm pipe complete all as specified and directed.

5

-

-

... More
S&F in repairs brass chromium plated, 600mm long between flanges tubular towel rail , 20mm dia, D type. fixed with and including chromium plated brass screws and wooden plastic cleats, complete all as specified and directed.

10

-

-

... More
S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.

10

-

-

... More
S&F as in replacement stainless steel plate rack of size 24" x 36" x 10" complete all as specidfied and directed.

3

-

-

... More
S & F in repair Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed.

5

-

-

... More
S & F in repairs fancy type Harrison rails, andodised aluminium alloy with fixing brackets, stops, rollers etc, of 20mm dia for window and doors with curtain rings and decorative doom holders fixed to wall with screw complete all as specified and as directed.

39

-

-

... More
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coveringscomplete all as specified and directed

522

-

-

... More
S&F Pre-Painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified.

407

-

-

... More
S&F Pre-Painted galvantume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified.

40

-

-

... More
S&F 0.63mm thick galvanised corrugated mild steel sheeting with two corrugation side lap fixed with 'J' type hook bolt and washer or self tapping screws in roof, wall etc.with grade of zinc coating 275 complete all as specified.

35

-

-

... More
S&F 0.63mm thick, plain galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed

40

-

-

... More
M&L for preparation of new zinc (or galvanised) surfaces to receive painting including washing and cleaning by coating with mordant solution including washing and cleaning and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed

35

-

-

... More
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation oards/slabs /blankets, any thickness, including cover fillets complete all as specified and directed.

178

-

-

... More
S&F exposed GI powder coated snap grid frame work for false ceiling of grid size 600 x600mm comprising of wall/cleat angle of size 25 x25 x0.35mm and main/cross tee of size 24 x38 x0.70mm with 4mm dia GI wire as suspender and including 4mm thick Plain E-Board including fixing arrangement from steel truss of any type and applying two coats of oil bound distemper over one coat of chalk whiting complete all as specified and directed.

178

-

-

... More
Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc all as directed.

115

-

-

... More
Material and labour for point wiring in repair for one light point or one fan point or one fan point controlled by one switch with using 1.5 Sq mm (nominal area) stranded copper conductor single core, PVC insulated & unsheathed cable, 1100 volts grade in existing concealed PVC conduit (medium grade) of 20mm dia/as exist on site all as specified and directed with using new sunken type Pre - coated 120 GSM (Gram Per m²) GI sheet pressed steel box including modular cover plate for mounting modular switch socket etch incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable (In green colour) as in earth wire connected to common earth dolly complete all as specified and directed. Note : (i) The quoted rates shall be deemed to be inclusive of sunction boxes/modular cover plate and cutting chases in brick walls/pillars etc for concealing the depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the portion of point wiring at for covering / fix sunken boards/terminal boxes/junction boxes of any shape and size . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for seperatly of cencern item of Sch’A’. (iii)The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at E/M complaint cell to carry out maintenance within stipulated time.without fail One light point controlled by one one/way switch complete all as specified and directed.

5

-

-

... More
One Fan point controlled by one one/way switch complete all as specified and directed

1

-

-

... More
One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed

1

-

-

... More
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size complete all as specified and directed

2

-

-

... More
One bell point controlled by one way switches complete all as specified and directed

1

-

-

... More
All as per item No. 68 above but using 2.5 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board complete all as specified and directed

1

-

-

... More
All as per item No.68 above but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.

1

-

-

... More
Material and labour for point wiring for one light point or one fan point or one fan point controlled by one switch with using 1.5 Sq mm (nominal area) stranded copper conductor single core, PVC insulated & unsheathed cable, 1100 volts grade in concealed PVC conduit (medium grade) of 20mm dia/as exist on site all as specified and directed with using new sunken type Pre - coated 120 GSM (Gram Per m²) GI sheet pressed steel box including 3 mm thick plastic laminated sheet top cover with 4 Nos SS screw and washer for mounting of paino type switches, sockets and fan regulators etc incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable (In green colour) as in earth wire connected to common earth dolly complete all as specified and directed. Note : (i) The quoted rates shall be deemed to be inclusive of sunction boxes/modular cover plate and cutting chases in brick walls/pillars etc for concealing the depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the portion of point wiring at for covering / fix sunken boards/terminal boxes/junction boxes of any shape and size . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for seperatly of cencern item of Sch’A’. The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at E/M complaint cell to carry out maintenance within stipulated time.without fail One light point controlled by one one/way switch complete all as specified and directed

5

-

-

... More
One Fan point controlled by one one/way switch complete all as specified and directed

3

-

-

... More
One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed.

2

-

-

... More
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size complete all as specified and directed.

5

-

-

... More
One bell point controlled by one way switches complete all as specified and directed.

2

-

-

... More
All as per item No. 75 above but using 2.5 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board complete all as specified and directed.

2

-

-

... More
All as per item No. 75 above but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.

1

-

-

... More
M&L for point wiring for one light or one fan point controlled by one switch with using 1.5 Sq mm (nominal area) stranded copper conductor single core PVC insulated & unsheathed cable 1100 volts grade in and incl PVC casing and capping of suitable size fixed on surface all as directed with using new sunken type pressed steel box/terminal boxes for mounting fittings/junction boxes not less than 1.6 mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with and incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor PVC insulated & unsheathed cable as in earth wire connected to commen earth dolly complete all as specified and directed. Note : (i) The quoted rates shall be deemed to be inclusive for fixing the PVC casing caping to surface with using PVC of covering sunken boards /terminal boxes/junction boxes of any shape and size with 3 mm thick suitable GI screws and cup washers. (ii) Fititngs like switches, sockets, regulators lamp holders light fittings shall be measured and paid appropriate item of schedule ‘A’ (iii) The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at E/M complaint cell to carry out maintenance within stipulated time.without fail One light point controlled by one one/way switch complete all as specified and directed.

40

-

-

... More
One Fan point controlled by one one/way switch complete all as specified and directed

5

-

-

... More
One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed

5

-

-

... More
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size complete all as specified and directed

15

-

-

... More
One light point controlled by two way switches complete all as specified and directed

3

-

-

... More
One bell point controlled by one way switches complete all as specified and directed.

4

-

-

... More
All as per item No. 82 above but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 2.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.

10

-

-

... More
All as per item No. 82 above but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed

2

-

-

... More
S & F in repair switch piano Modular type single pole one way 6 Amp 240 Volts complete all as specified and directed

89

-

-

... More
S & F in repair switch piano Modular type single pole one way 16 Amp 240 Volts complete all as specified and directed

13

-

-

... More
S & F in repair socket only 6 Amps 2 in 1 Socket with Shutter Modular type 240 Volt complete all as specified and directed

30

-

-

... More
S & F in repair socket only 6/16 Amps Twin Socket Modular type 240 Volt complete all as specified and directed

13

-

-

... More
S & F in repair in repair Bell push switch Modular type single pole one way 10 Amp 240 Volts complete all as specified and directed

7

-

-

... More
S & F in repair in repair Fan Regulator 2M FSC Modular type 240 Volts complete all as specified and directed

9

-

-

... More
S & F in repair ceiling rose PVC polycarbonate isolated body 63.5x20 mm three terminal complete all as specified and directed.

67

-

-

... More
S & F in repair lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed

20

-

-

... More
S & F in repair sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/PVC Conduit or in existing concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed.

40

-

-

... More
All as above item No.98 but using 4 Sqmm cable for phase and neutral and 4 Sqmm for earth wire. Note:(point wiring): The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at E/M compaint cell to carry out maintenance within stipulated time.without fail complete all as specified and directed

50

-

-

... More
S & F in repair Concealed Galvanised (GI) metal flush Boxes Modular 3 module concealed and making good the disturbed surface by white cement&Existing color of bld distamper complete and all as directed by Engr-in-charge.

3

-

-

... More
S & F in repair Concealed Galvanised (GI) metal flush Boxes Modular 4 module concealed along with white cover plate and making good the disturbed surfaceby white cement&Existing color of bld distamper complete and all as directed by Engr-in-charge.

2

-

-

... More
S & F in repair Concealed Galvanised (GI) metal flush Boxes Modular 6 module along with white cover plate concealed and making good the disturbed surfaceby white cement & Existing color of bld distamper complete and all as directed by Engr-in-charge.

2

-

-

... More
S&fix in repair 5 Amps Socket only 3 Pin flush type complete all as specified and directed.

20

-

-

... More
S&f in repair 15 Amps Socket only 3 Pin flush type complete all as specified and directed.

10

-

-

... More
S & F in repair 15 Amps Switch flush type complete all as specified and directed.

15

-

-

... More
S & F in repair switchsocket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal 240 Volt complete all as specified and directed

10

-

-

... More
S & F in repair switch socket combination 3 pin 16 Amp 2 flush type complete all as specified and directed

5

-

-

... More
S & F in repair switch piano flush type single pole one way 5 Amp 240 Volts complete all as specified and directed

30

-

-

... More
S&fix in repair modular switch one way 6 Amps 1 module 240 Volts complete all as specified and directed

20

-

-

... More
S & F in repair modular switch one way 16 Amps 1 module 240 Volts complete all as specified and directed

20

-

-

... More
S & F in repair modular switch two way 6 Amps 1 module 240 Volts complete all as specified and directed

15

-

-

... More
S & F in repair modular bell push way 6 Amps 1 module 240 Volts complete all as specified and directed

5

-

-

... More
S & F in repair modular socket outlet 6A 3 pin 2 module 240 Volts complete all as specified and directed

20

-

-

... More
S & F in repair modular socket outlet 6A/16 5 pin 2 module 240 Volts complete all as specified and directed

20

-

-

... More
S & F in repair modular fan regulator 120W-2 module 240 Volts complete all as specified and directed

10

-

-

... More
S & F in repair Bell push flush type single pole 5 Amp 240 Volts complete all as specified and directed.

5

-

-

... More
S & F in repair Bell ding dong type, one way, 240 volts, AC, ISI marked complete all as specified and directed

5

-

-

... More
S & F in repair ceiling rose in replacement surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked complete all as specified and directed.

20

-

-

... More
S & F in repair stright/Angle bulb holder pvc body complete.Make: Anchor, kolors, material to be supplied as per demand of qty is ordered by Engineer -in- charge as per site requirement complete all as specified and directed.

8

-

-

... More
S & F in repair in Stepped/socket type electronic fan regulator heavy duty typeA/C 240 V complete all as specified and directed.

5

-

-

... More
S & F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.

4

-

-

... More
S & F in repair TPN DBs Vertical type 4 way DB 415 volt with provision for FP MCB as incomer and MCB SP as outgoing complete all as specified and directed.

1

-

-

... More
S & F in repair sheet metal enclosure for single pole and neutral 12 way DB 240 voilts, 100 Amp rated bus bar complete all as specified and directed.

1

-

-

... More
S & F in repair sheet metal enclosure for single pole and neutral 08 way DB 240 voilts, 100 Amp rated bus bar complete all as specified and directed.

2

-

-

... More
S & F in repair sheet metal enclosure for single pole and neutral 04 way DB 240 voilts, 100 Amp rated bus bar complete all as specified and directed.

2

-

-

... More
S & F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps complete all as specified and directed.

2

-

-

... More
S & F in repair MCB SP 5 to 32 Amps 10KA 'C' curve and240 volts current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed

18

-

-

... More
S & F in repair MCB SPN 32 Amp, 10 KA, 240 Volts complete all as specified and directed.

6

-

-

... More
S & F in repair MCB SPN 40 to 63 Amp 240 Volts complete all as specified and directed.

5

-

-

... More
S & F in repair MCB SP & N up to 100 Amp 240 Volts complete all as specified and directed.

2

-

-

... More
S & F in repair MCB four pole up to 80 Amp 415 Volts complete all as specified and directed.

2

-

-

... More
S & F in repair MCB (Four pole) 100 Amp 415 Volts complete all as specified and directed.

1

-

-

... More
S & F in repair MCCB 100 Amp 16 KA complete all as specified and directed.

1

-

-

... More
M&L in repair for Earthing complete as per electrical plate NO.3 of MES SSR Part I with galvanised steel plate earth electrode 600 mm x 600mm x 6 mm burried directly in ground in a pit of depth not less than 2.25 metre below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and incl galvanised iron or steel earth lead wire 4 mm dia by mneans of bolts, nuts, check nuts and washers of galvanised iron or steel earthing wire protected by galvanised iron or steel pipe 15 mm dia light grade and connected to main switch board or main control board watering pipe shall be 20 mm dia GI medium grade incl excavation and earth work in any type of soil, PCC pit, CI Frame, RCC covers complete all as specified and directed.

1

-

-

... More
S & F in repair PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm x 50 mm complete all as specified and directed.

2

-

-

... More
All as per serial item No. 135 above but for size 175x100x50 mm deep complete all as specified and directed.

2

-

-

... More
All as per serial item No. 135 above but for size 200x150x50 mm deep complete all as specified and directed.

2

-

-

... More
All as per serial item No. 135 above but for size 250x200x50 mm deep complete all as specified and directed.

1

-

-

... More
All as per serial item No. 135 above but for size 350x200x50 mm deep complete all as specified and directed.

1

-

-

... More
S & F in repair single phase electronic meters temper proof LCD display with polycarbonate cover 230 V,10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH Class 1 complete all as specified and directed.

2

-

-

... More
S & F in repair of PVC conduit size 25mm Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories including chase cutting such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed

30

-

-

... More
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed

40

-

-

... More
S & F in repair LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete complete all as directed by Engr-in-charge.

10

-

-

... More
S & F in repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light 20W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed by Engr-in-charge.

40

-

-

... More
S & F in repair LED lights fitting 1x 20W, 220V, AC LED Batten with Opal Diffuser, IP20, Inbuilt Motion Sensor based Auto Dim/Brightness decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed by Engr-in-charge.

10

-

-

... More
S & F in repair LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, including 600mm long bracket with fastner bolt nut and washer for fix in wall complete all as specified and directed.

8

-

-

... More
S & F in repair LED light fittings small 6 watt round/square type white/yellow complete with choke/driver complete all as specified nd as directed Make : Hallonix/C&S/Orient/Havells/Phillips/Surya

6

-

-

... More
S & F in repair recess mounted down lighter 12 Watts complete all as specified and directed yellow/white AS Per Sample complete all as specified and directed

10

-

-

... More
S & F in repair LED bulb Lamp 09/10 Watts Retrofit B22 holder type base wth polycorbonate diffuser and alluminiun heat sink complete all as specified and directed.

35

-

-

... More
Taking down fan, sealing cable end,dismantling blades and removing fan and blades to E/M store complete all as specified and directed

10

-

-

... More
Taking down and refixing of storage type water heater from wall by disconnecting the electric connection and water inlet/outlet connection from main and repairing the water heater storage type capacity 25 ltrs of any type and make, checking the serviceablity of all parts such as inner vesser, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of unserviceable parts and assembly completet (considered as one unit) and installing and testing the same as per the direction of Engineer-In-Charge.

8

-

-

... More
All as per serial item No 151 above but for capacity 50 ltrs complete all as specified and directed.

2

-

-

... More
S & F in repair of heating elements, 1.5/2 KW any type any size ISI mark 230 volts complete all as specified and directed.

5

-

-

... More
S & F in repair of thermostat immersion point type 15 Amps, 230250 volts/AC ISI marked complete all as specified and directed.

5

-

-

... More
S & F in repair ,stainless steel flexible conneciton pipe with brass check nuts complete as per site requirement all as specified and directed by Engineer-In-Charge.

5

-

-

... More
S & F in repair of indicator lamp assembly for geyser complete all as specified and directed by Engr-In-Charge.

5

-

-

... More
S & F in repair 15 Amp plug top complete all as specified and directed.

10

-

-

... More
S & F in repair earth industrial plug top for socket for industrial socket metal glad suitable for 16 Amps metal glad MCB DB complete all as specified and directed.

2

-

-

... More
S & F in repair industrial socket metal glad suitable for 16 Amps 240 volts metal glad MCB DB complete all as specified and directed.

2

-

-

... More
S & F in repair 4 sq mm 3 core flexible copper cable for maintenance of geyser, and cooling appliances. (In Role of 90 RM) complete all as specified and directed.

20

-

-

... More
S & F in repair syphon assembly suitable for 25/50 ltr geyser complete including nuts and washer complete all as specified and directed.

5

-

-

... More
S & F in repair geyser brass tank for 25/50 ltr geyser complete including nuts, washer, glass wool etc complete all as specified and directed.

4

-

-

... More
S & F in repair 23/.0076 sq mm 2 core flexible copper cable for maintenance of light/ fan etc complete all as specified and directed.

40

-

-

... More
M&L for attending complaint of ceiling fan/exhaust fan/air circulator/ cabin fan such as hanging/dismantling/loose connection etc complete all as specified and directed

40

-

-

... More
S & F in repair of capacitor 4 MFD suitable for any make, type & sweep ceiling fan, exhaust fan, cabin fan & pedestal fan of complete all as specified and directed.

10

-

-

... More
S & F in repair capacitor of 2.5 MFD of ISI marked complete all as specified and directed.

10

-

-

... More
M & L in repair of rewinding of ceiling fans 1200/1400mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed

20

-

-

... More
M & L in repair of rewinding of Exhaust fan 300 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed

10

-

-

... More
M & L in repair of rewinding Exhaust fan 450 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed

4

-

-

... More
M & L in repair of fan bearing 6201/6202 of ceiling fan of any capacity any size all as specified and directed Note: Replacement of bearing to be carried out at E/M complaint cell at LMS only exceptional case where lathe work is required then only fan to be taken at workshop.

4

-

-

... More
M & L in repair of bearing/bush of exhaust fan/cabin fan/air circulator of any capacity any size all as specified and directed. Note: Replacement of bearing to be carried out at E/M complaint cell at LMS only exceptional case where lathe work is required then only fan to be taken at workshop.

5

-

-

... More
S & F in repair exahust fan blade 300mm sweep with locking nut complete all as specified and directed

3

-

-

... More
S & F in repair ceiling fan blade 1200mm/1400 mm complete all as specified and directed.

5

-

-

... More
Dismantling and taking out existing unserviceable geyser and deposited to E/M store yard complete all as specified and directed

3

-

-

... More
M&L in repair for repairing/servecing/welding/brazzing/reinsulating and cladding of hot water tank all as specified and directed.

1

-

-

... More
S & F in repair collecter glass (toughned) of solar water heater all as specified and directed.

2

-

-

... More
Supply and laying in repair CPVC pipe 1" dia including elbow, union, socket,bend etc complete all as specified and directed

10

-

-

... More
Supply and laying in repair CPVC pipe 1.5" dia including elbow, union, socket,bend etc complete all as specified and directed

10

-

-

... More
S & F in repair NRV 1" dia all as specified and directed.

2

-

-

... More
S & F in repair NRV 1.5" dia all as specified and directed.

2

-

-

... More
S & F in repair union 1" dia all as specified and directed.

2

-

-

... More
S & F in repair union 1.5" dia all as specified and directed.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.