Military Engineer Services Tender

View complete overview of Manipur MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date1 May 2024
Closing Date29 May 2024
Tender Amount₹ 32,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down shutter of any description and removing frome site exc. 1 Sqm & n. exc. 2 Sqm each leaf complete all as specified and directed.

4

-

-

... More
Taking down shutter of any description and removing frome site n exc. 1 Sqm each leaf complete all as specified and directed.

6

-

-

... More
S&F II nd class hard wood (haldu/ hallock) plain, solid, straight chowkats & frames , wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.

0.2

-

-

... More
S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, both face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed.

14.7

-

-

... More
S&F 2nd Class H.W. Skeleton shutter 35 mm thick open rebated & prepared to receive glass, gauze, etc. divided into squares with plain chamfered or rounded & rebated sash bars (of any nos)as spd in SSR Pt-I Sec 8 Cl. 8.24.(a) as per specification complete all as specified and directed.

8.4

-

-

... More
S&F 2nd Class H.W. Skeleton shutter 35 mm thick open rebated & prepared to receive glass, gauze, etc. divided into squares with plain chamfered or rounded & rebated sash bars (of any nos)as spd in SSR Pt-I Sec 8 Cl. 8.24.(b) as per specification complete all as specified and directed.

12.96

-

-

... More
S&F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube in opening as per specification & drawing complete all as specified and directed.

19.85

-

-

... More
S&F factorymade solid pannel PVC door shutter 30mm thick consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with neat moulded plan colour PVC 'C' channel having a PVC sheet strips of 20mm width stuck in side with solvent cement for styles and plain colour PVC sheets for top rails, lock rail and bottom rail on eithor side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheets to be fitted in the MS frame welded/sealed to the stiles, and rails with suitable PVC sheet bedding and jointed together with solvenet cement, supply and fixing in the frame at site as per specification complete all as specified and directed.

11.34

-

-

... More
S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.

15

-

-

... More
M&L two coat of synthetic enamel painting to wooden surfaces (frame & shutter) over a coat of primer incl preparation of wooden surface.Surfaces of any description, not otherwise descri-bed, over 10cm width or girth complete all as specified and directed.

46.2

-

-

... More
Taking down chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) and refixing in same opening complete all as specified and directed by Engr-in-Charge.

18

-

-

... More
Taking down chowkats or frames exc. 1.5 sq. m but n exc 4 sqm each with shutters (without taking off shutters from the frames)and refixing in same opening complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply and fix for aluminium powder coated three track sliding window with two glazed shutters, one 4mm thick float glass ordinary quantity and one shutter of stainless steel wire mesh 0.36mm nominal dia of wire & average width of aperture 1.40mm including good quality of bearing handle, locks, PVC rubber lining, rollers etc complete all as specified and as directed.

9.6

-

-

... More
S&F ventiltors/ louvers with parttially guaged shutter using 5 mm thick x 10 cm wide frosted glass strips and following aluminium powder coated sections conforming to catalogue complete all as specified and directed.

1.8

-

-

... More
S & F aluminium anodised Hasp and staple 75mm , safety type, mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.

16

-

-

... More
S&F 100 mm long Aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.

12

-

-

... More
Supply and fix Extruded aluminium alloy handles, 100 mm long fabricated type complete all as specified and directed.

10

-

-

... More
S&F 100 mm long Stainless Steel butt hinges medium weight colld rolld complete all as specified and directed.

30

-

-

... More
S&F 150mm aluminium anodised of extruded section barrel tower bolts complete all as specified and directed.

28

-

-

... More
S&F 200mm aluminium anodised of extruded section barrel tower bolts complete all as specified and directed.

48

-

-

... More
S&F 150mm long alumiunium handles cast type anodised complete all as specified and directed.

20

-

-

... More
S&F 140mm long floor door stopper of brass body and tongue with had drawn steel spring complete all as specified and directed.

20

-

-

... More
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed 300mm long complete all as specified and directed

10

-

-

... More
S&F in repairs 100 mm long Stainless Stee butt hinges medium weight colld rolld complete all as specified and directed.

50

-

-

... More
S&F in repairs 150 mm long Aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.

40

-

-

... More
Supply and fix in repairs Extruded aluminium alloy handles, 150mm long complete all as specified and directed.

35

-

-

... More
S&F in repairs 300 mm long Aluminium allow anodised sliding door bolt with hasp staple (bolt type ) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast alu allow complete all as specified and directed.

30

-

-

... More
Supply and fix in repairs floor door stopper of aluminium body and tongue anodised with hard drawn steel spring fixed in floor over all length of cover plate 150mm complete all as specified and directed.

25

-

-

... More
S & F in repairs fancy type decorative Drapary rod of 20mm dia for window and doors with curtain rings and decorative doom holders fixed to wall with screw complete all as specified and directed.

80

-

-

... More
S&F in Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.

15

-

-

... More
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.

22

-

-

... More
S&F 3 mm thick sheet glass ordinary quality & glazing with oil putty in squares n. exc. 0.5 Sqm in each pane complete all as specified and directed.

10

-

-

... More
S&F figured glass 3 mm thick, pin head type & glazing with oil putty in squares n. exc. 0.5 Sqm in each pane complete all as specified and directed.

10

-

-

... More
Supply only 5.5 mm thick sheet glass, selected quality, in square exc 0.5 Sqm each pane including solar control film 25 micron reflective type over it complete all as specified and directed.

2

-

-

... More
S&F door closer (aluminium extuded body section) hydreulically regulated, ,designation No 1 universal type, suitable for door shutters up to 700mm in width and of wieght not more than 35Kg complete all as directed.

4

-

-

... More
S&F in repairs vitreous china European type wash down water closet pan (Pedestal pattern) of white colour including plastic water closet seat black closed pattern with flat bottom (with MS or CP hinging device) and fixing bolts, P or S trap, necessary inlet and outlet connections including syphonic action type low level PVC flushing cistern of 10 lit capacity white in colour and PVC flush pipe 32mm dia complete all as specified and directed by Engineer -in- Charge.

6

-

-

... More
Supply and fix in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests Complete all as specified and directed

5

-

-

... More
S&F in repair PVC flushing cistern 10 ltrs capacity ISI marked incl PVC down pipe and connection etc complete all as specified and directed.

15

-

-

... More
S&F in repairs plastic water closet seat cover black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminum hinging device complete all as specified and directed.

6

-

-

... More
Supply only Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed.

10

-

-

... More
S&F Vitreous china coloured Wash Hand Basin (Oval Shape) 580mm X 450mm fixed in repairs including 15 mm pillar cock cast copper alloy CP, 15mm cast copper stop valve, 32 mm brass CP waste fitting & 15 mm PVC connection pipe 450 mm long fixed in repairs complete all as specified and directed.

4

-

-

... More
Supply and fix in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union fixed in repair complete all as specified and directed.

4

-

-

... More
S&F in repair for stop cock copper alloy CP screwed down high pressure with crutch or butterfly handle screwed both ends for iron/pipe or for union and fixed 15 mm bore in repairs complete all as specified and directed.

30

-

-

... More
S&F in repair bib taps cast copper alloy with crutch or butterfly handle, chromium plated fancy type screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs complete all as specified and directed.

30

-

-

... More
S&F in repairsHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.

15

-

-

... More
S&F in repairs 32/50mm dia PVC waste pipe for kitchen sink , WHB , Urinal etc complete all as specified and directed.

8

-

-

... More
Supply and fix in repair 15mm bore piller taps of cast copper with capstan head CP screwed down high pressure with or without lettered hot and cold with long screwed shank and fly nut for iron pipe and fixed in repairs complete all as specified and directed.

15

-

-

... More
S&F in repair Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.

5

-

-

... More
S&F PVC connections 15 mm size with PTMT nuts to length 450 mm in repairs complete all as specified and directed.

40

-

-

... More
S&F in repair Brass, Chromium plated, Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.

15

-

-

... More
S&F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.

20

-

-

... More
Supply and fix in repairs brass Chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.

10

-

-

... More
S & F 600mmx450mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.

25

-

-

... More
Taking down steel tubing and connections including cleaning for re-fixing or removal to store of 15 mm bore complete all as specified and directed.

15

-

-

... More
Taking down steel tubing necessary fittings connection etc for 20 mm bore pipe complete all as specified and directed.

15

-

-

... More
S&F GI tubing 15mm dia medium grade galvannised with all fitting &fixed complete to walls & ceiling or laid in floors complete all as specified and directed.

15

-

-

... More
S&F 20mm thick GI Tubing medium grade galvanised with all fitting and fixed complete all as specified and directed.

15

-

-

... More
S&F in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement dia of outlet in 75mm complete all as specified and directed.

8

-

-

... More
S&F in repairs 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors complete all as specified and directed.

25

-

-

... More
S&F in repairs 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors complete all as specified and directed.

20

-

-

... More
S&F in repairs 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to walls complete all as specified and directed.

20

-

-

... More
S&F in repairs 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to walls complete all as specified and directed.

20

-

-

... More
S&F in repairs PVC (SWR) bends of any radius of 110mm dia. With oval and access door complete all as specified and directed.

5

-

-

... More
S&F in repairs PVC (SWR) bends of any radius of 75mm dia complete all as specified and directed.

5

-

-

... More
S&F in repairs PVC (SWR) branch piece (single ‘Y’) equal or unequal for 110mm dia PVC pipe complete all as specified and directed.

5

-

-

... More
S&F in repair PVC(SWR) branch piece (single ‘Y’) equal or unequal for 75mm dia PVC pipe complete all as specified and directed.

5

-

-

... More
S&F in repair for PVC (SWR) junction (single ‘T’) with access door for 110mm dia pipe complete all as specified and directed.

5

-

-

... More
S&F in repair for PVC (SWR) junction (single ‘T’) with access door for 75mm dia pipe complete all as specified and directed.

5

-

-

... More
S&F in repair for PVC (SWR) vent cowl suitable for 110mm dia PVC pipe complete all as specified and directed.

5

-

-

... More
S&F in repair for PVC (SWR) vent cowl suitable for 75mm dia PVC pipe complete all as specified and directed.

10

-

-

... More
Supply and fix in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed in repairs of pipe 20 mm dia complete all as specified and directed.

8

-

-

... More
S/F in repair sinks made of stainless steel of 1 mm thick kitchen sink with plug washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495 x 420 mm bowl size 410 mm x 330 mmx 160 mm complete all as specified and directed.

3

-

-

... More
Dismantling Water Tanks & removing from site, capacity of tanks exc 250 litres & n. exc. 500 Litres capacity each complete all as specified and directed.

6

-

-

... More
Dismantling Water Tanks & removing from site, capacity of tanks 500 ltr and n exc 1000 ltr complete all as specified and directed.

7

-

-

... More
S/F Rotational moulded polyethelene water storage tanks (cylindrical, vertical with closed top) hoisted & fixed in position all as specified in SSR Pt-I, 500 litre capacity complete all as specified and directed.

6

-

-

... More
S/F Rotational moulded polyethelene water storage tanks (cylindrical, vertical with closed top) hoisted & fixed in position all as specified in SSR Pt-I, exc 1000 ltr capacity complete all as specified and directed.

3

-

-

... More
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, Capacity exc 250 litrs n exc 500 litrs, cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed.

2

-

-

... More
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, Capacity exc 500 litrs n exc1000 litrs and cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed.

169

-

-

... More
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.

70

-

-

... More
S&F for exposed GI powder coated snap grid frame work for false ceiling of grid size 600X600mm comprising of wall /cleat angle of size 24X 38X0.70mm with 4mm dia GI providing 4mm thick 'E' board in ceiling with galvanised iron snap frame of 'T' Section 24x38x0.70mm wall/cleat angle 25x25x0.35mm thick and hanging with 2mm GI wire all fixed arrangement will be done as per manfraxture instruction including two coat of oil bound distemper and one coat of primer complete all as specified and directed.

30

-

-

... More
S&F 4mm thick ply wood grade BWR (type BB) fixed with nails to the timber frame work as in wall complete all as specified and directed.

30

-

-

... More
M&L for RAJSHRI brand insulated PVC wall panelling consisting of PVC insulated panels having wall thickness of 2mm (+or -0.2) PVC sheet opf density 600 Kg /CbmManufactured by an ISO-9001-2015 certified company, and the desired thickness of EPS ( Dependent on the insulation required) screwed into the wall using screws of adequate length. The screws shall be placed at a distance of 150mm and shall be 25mm from the edge of the insulated panelon all four sides of the panel. The PVC strips of 5mm ( + or - 0.25) thick PVC sheet of width 75mm feathered at the edges shall be stuck using solvent cement adhesive at the places where two panels are joined, so as to cover the screw of both panels, using solvent cement 900 heat bent strips of 5mm thick PVC sheets of width 75mm x75mm feathered at the edges shall be stuck at wall joints / pillars etccomplete all as specified and directed.

30

-

-

... More
M&L for Second class hardwood Weather boarding, clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give 20mm laps and fixed complete all as specified and directed.

13

-

-

... More
Material and labour for 0.90mm thick decorative laminate type 1 of surface finish, colour, pattern and size as approved, fixed with approved adhesive as per manufacturer’s instructions on horizontal and vertical surfaces etc. complete all as specified and as directed.

13

-

-

... More
Material and labour for 4mm thick one side decorative group match veneer complete all as specified and as directed.

13

-

-

... More
Dismantling of timper scantling 40 sq .cm and over in section,in any position complete all as specified and directed.

0.9

-

-

... More
M&L for second class hard wood in scantling wrought, timber framed & fixed complete all as specified and directed.

0.51

-

-

... More
Fixing only second class hard wood in scantling clean sawan , timber framed & fixed complete all as specified and directed.

0.39

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.

2

-

-

... More
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, including one coat shop primer complete all as specified and directed.

200

-

-

... More
M & L two coat of synthetic enamel paint on steel surfaces over one coat of zinc primer including preparation of new steel surfaces exceeding 10 cm width or girth complete all as specified and directed.

10

-

-

... More
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings ,any description and in any positioncomplete all as specified and directed.

208

-

-

... More
M&L for Pre- painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr -in- Charge.

180

-

-

... More
S&F Galvanised, corrugated mild steel sheeting pf 0.63mm thickness with two corrugations side lap, fixed with L type or J type or cranked hook bolts, in roofs, walls etc. with grade of zinc coating 275 complete all as specified and directed.

15

-

-

... More
S&F galvanized plain mild steel sheeting 0.63 mm thick in ridges, hips, valley gutters, drip & straight flashings (length and firth as fixed ) with grade of zink coating 275 complete all as specified and directed.

13

-

-

... More
M&L for filleting in any position & to any shape, sectional area exc.25 but n. exc. 50 sqcm. In CM 1:4 including all mitres , stops etc complete all as specified and directed.

10

-

-

... More
Demolition of brick work or stone/ boulders masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work and precast concrete articles complete all as specified and directed.

5.73

-

-

... More
M&L for brick work with subclass 'B' brick straight or curved on plan 6m mean radious built in CM (1:6) etc complete all as specified and directed.

4

-

-

... More
M&L brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius built in cement mortar 1:4 using old size bricks as in half brick thick wall complete all as specified and directed.

15

-

-

... More
Demolition of cement concrete in ground floors and paving not exc 15cm thick (below or above ground level) un-reinforced complete all as specified and directed.

1.5

-

-

... More
M&L for 75mm thick PCC (1:4:8) type C2 (using 40mm graded aggregate) as in sub base/flooring/ paving complete all as specified and directed.

8

-

-

... More
M&L for 75mm thick PCC (1:3:6) type B2 (using 20mm graded aggregate) as in plinth protection/hard standing, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.

12

-

-

... More
Taking down cement plaster on stone / Brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.

198

-

-

... More
M&L for rendering 10mm thick plaster on fair faces of brick work or concrete surfaces (1:6) finished the surface even and Smooth without extra cement complete all as specified and directed.

66

-

-

... More
M&L for rendering in CM 1:4 with 15mm cement plaster with water proofing compound @ 2% by weight of cement or as per manufacture's instrs having smooth and fair finish all as specified and directed by engineer - in - charge Note :- (1) Use of Dimapur Sand to plaster. (2) WPC pdr shall be measured and paid separately.

102

-

-

... More
Supply only integral water proofing compound complete all as specified and directed.

18.93

-

-

... More
M&L for rendering 5 mm thick plaster on ceiling concrete surfaces as in CM (1:3) finished even & Smooth without using extra cement complete all as specified and directed.

30

-

-

... More
M&L for three coat of white wash to newly plastered surfaces of on ceiling complete all as specified and directed.

30

-

-

... More
M&L for two coats of oil bound distemper over a coat alkali resistent primer to newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed.

66

-

-

... More
M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint over a alkali resistent primer complete all as specified and directed.

102

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.

178

-

-

... More
M&L for colored Non Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colored cement to match, including 15 mm thick screed bed or bedded layer in cement mortar 1:6 for laying floor finish complete all as specified and directed.

73

-

-

... More
M&L for colored glazed ceramic tiles (300mm x450mm) x 7 mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or colored cement to match including 10 mm thick backing coat in cement mortar (1:4) on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing to receive /fixing dado/ skirting tile complete all as specified and directed.

55

-

-

... More
M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over 15mm thick screed bed in CM 1:6 etc set and jointed in neat cemet slurry and pointed in white or coloured cement to match complete all as specified and directed.

50

-

-

... More
Dismantling of stone slab in any description or thickness, laid bedded jointed in any morter complete all as specified and directed.

0.67

-

-

... More
Material and labour for Granite(of any type) 18 to 20 mm thick work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and directed.

6.7

-

-

... More
Material and labour for bitumen patches on roof sheet to arised the leakage seapakge complete all as specified and directed.

15

-

-

... More
Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc all as directed.

134

-

-

... More
Material and labour for point wiring in repair for one light point or one fan point or one fan point controlled by one switch with using 1.5 Sq mm (nominal area) stranded copper conductor single core, PVC insulated & unsheathed cable, 1100 volts grade in existing concealed PVC conduit (medium grade) of 20mm dia/as exist on site all as specified and directed with using new sunken type Pre - coated 120 GSM (Gram Per m²) GI sheet pressed steel box including modular cover plate for mounting modular switch socket etch incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable (In green colour) as in earth wire connected to common earth dolly complete all as specified and directed. Make PVC cable .Havells/Finolex/Polycab Note : (i) The quoted rates shall be deemed to be inclusive of sunction boxes/modular cover plate and cutting chases in brick walls/pillars etc for concealing the depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the portion of point wiring at for covering / fix sunken boards/terminal boxes/junction boxes of any shape and size . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for seperatly of cencern item of Sch’A’. (iii)The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at E/M complaint cell to carry out maintenance within stipulated time.without fail One light point controlled by one one/way switch complete all as specified and directed.

3

-

-

... More
One Fan point controlled by one one/way switch complete all as specified and directed

2

-

-

... More
One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed

1

-

-

... More
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size complete all as specified and directed

2

-

-

... More
One bell point controlled by one way switches complete all as specified and directed

1

-

-

... More
All as per item No. 121 above but using 2.5 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board complete all as specified and directed

2

-

-

... More
All as per item No.121 above but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.

1

-

-

... More
Material and labour for point wiring for one light point or one fan point or one fan point controlled by one switch with using 1.5 Sq mm (nominal area) stranded copper conductor single core, PVC insulated & unsheathed cable, 1100 volts grade in concealed PVC conduit (medium grade) of 20mm dia/as exist on site all as specified and directed with using new sunken type Pre - coated 120 GSM (Gram Per m²) GI sheet pressed steel box including 3 mm thick plastic laminated sheet top cover with 4 Nos SS screw and washer for mounting of paino type switches, sockets and fan regulators etc incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable (In green colour) as in earth wire connected to common earth dolly complete all as specified and directed. Make PVC cable .Havells/Finolex/Polycab Note : (i) The quoted rates shall be deemed to be inclusive of sunction boxes/modular cover plate and cutting chases in brick walls/pillars etc for concealing the depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the portion of point wiring at for covering / fix sunken boards/terminal boxes/junction boxes of any shape and size . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for seperatly of cencern item of Sch’A’. The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at E/M complaint cell to carry out maintenance within stipulated time.without fail One light point controlled by one one/way switch complete all as specified and directed

2

-

-

... More
One Fan point controlled by one one/way switch complete all as specified and directed

1

-

-

... More
One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed.

1

-

-

... More
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size complete all as specified and directed.

2

-

-

... More
One bell point controlled by one way switches complete all as specified and directed.

1

-

-

... More
All as per item No. 128 above but using 2.5 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board complete all as specified and directed.

1

-

-

... More
All as per item No.128 above but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.

1

-

-

... More
M&L for point wiring for one light or one fan point controlled by one switch with using 1.5 Sq mm (nominal area) stranded copper conductor single core PVC insulated & unsheathed cable 1100 volts grade in and incl PVC casing and capping of suitable size fixed on surface all as directed with using new sunken type pressed steel box/terminal boxes for mounting fittings/junction boxes not less than 1.6 mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with and incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor PVC insulated & unsheathed cable as in earth wire connected to commen earth dolly complete all as specified and directed.Make PVC cable .Havells/Finolex/Polycab Note : (i) The quoted rates shall be deemed to be inclusive for fixing the PVC casing caping to surface with using PVC of covering sunken boards /terminal boxes/junction boxes of any shape and size with 3 mm thick suitable GI screws and cup washers. (ii) Fititngs like switches, sockets, regulators lamp holders light fittings shall be measured and paid appropriate item of schedule ‘A’ (iii) The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at E/M complaint cell to carry out maintenance within stipulated time.without fail One light point controlled by one one/way switch complete all as specified and directed.

50

-

-

... More
One Fan point controlled by one one/way switch complete all as specified and directed

10

-

-

... More
One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed

10

-

-

... More
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size complete all as specified and directed

25

-

-

... More
One bell point controlled by one way switches complete all as specified and directed.

4

-

-

... More
All as per item No.135 above but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 2.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.

15

-

-

... More
All as per item No.135 above but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed

3

-

-

... More
S & F in repair switch piano Modular type single pole one way 6 Amp 240 Volts complete all as specified and directed

109

-

-

... More
S & F in repair switch piano Modular type single pole one way 16 Amp 240 Volts complete all as specified and directed

18

-

-

... More
S & F in repair socket only 6 Amps 2 in 1 Socket with Shutter Modular type 240 Volt complete all as specified and directed

41

-

-

... More
S & F in repair socket only 6/16 Amps Twin Socket Modular type 240 Volt complete all as specified and directed

18

-

-

... More
S & F in repair in repair Bell push switch Modular type single pole one way 10 Amp 240 Volts complete all as specified and directed

6

-

-

... More
S & F in repair in repair Fan Regulator 2M FSC Modular type 240 Volts complete all as specified and directed

13

-

-

... More
S & F in repair ceiling rose PVC polycarbonate isolated body 63.5x20 mm three terminal complete all as specified and directed.

87

-

-

... More
S & F in repair lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed

15

-

-

... More
S & F in repair sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/PVC Conduit or in existing concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed.

40

-

-

... More
All as above item No.150 but using 4 Sqmm cable for phase and neutral and 4 Sqmm for earth wire. Note:(point wiring): The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at E/M compaint cell to carry out maintenance within stipulated time.without fail complete all as specified and directed

50

-

-

... More
S & F in repair Concealed Galvanised (GI) metal flush Boxes Modular 3 module concealed and making good the disturbed surface by white cement&Existing color of bld distamper complete and all as directed by Engr-in-charge.

5

-

-

... More
S & F in repair Concealed Galvanised (GI) metal flush Boxes Modular 4 module concealed along with white cover plate and making good the disturbed surfaceby white cement&Existing color of bld distamper complete and all as directed by Engr-in-charge.

2

-

-

... More
S & F in repair Concealed Galvanised (GI) metal flush Boxes Modular 6 module along with white cover plate concealed and making good the disturbed surfaceby white cement & Existing color of bld distamper complete and all as directed by Engr-in-charge.

5

-

-

... More
S&fix in repair 5 Amps Socket only 3 Pin flush type complete all as specified and directed.

30

-

-

... More
S&f in repair 15 Amps Socket only 3 Pin flush type complete all as specified and directed.

15

-

-

... More
S & F in repair 15 Amps Switch flush type complete all as specified and directed.

15

-

-

... More
S & F in repair switchsocket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal 240 Volt complete all as specified and directed

15

-

-

... More
S & F in repair switch socket combination 3 pin 16 Amp 2 flush type complete all as specified and directed

5

-

-

... More
S & F in repair switch piano flush type single pole one way 5 Amp 240 Volts complete all as specified and directed

35

-

-

... More
S & F in repair switch piano flush type single pole two way 5 Amp 240 Volts complete all as specified and directed

5

-

-

... More
S&fix in repair modular switch one way 6 Amps 1 module 240 Volts complete all as specified and directed

20

-

-

... More
S & F in repair modular switch one way 16 Amps 1 module 240 Volts complete all as specified and directed

20

-

-

... More
S & F in repair modular switch two way 6 Amps 1 module 240 Volts complete all as specified and directed

10

-

-

... More
S & F in repair modular bell push way 6 Amps 1 module 240 Volts complete all as specified and directed

5

-

-

... More
S & F in repair modular socket outlet 6A 3 pin 2 module 240 Volts complete all as specified and directed

20

-

-

... More
S & F in repair modular socket outlet 6A/16 5 pin 2 module 240 Volts complete all as specified and directed

10

-

-

... More
S & F in repair modular fan regulator 120W-2 module 240 Volts complete all as specified and directed

10

-

-

... More
S & F in repair Bell push flush type single pole 5 Amp 240 Volts complete all as specified and directed.

5

-

-

... More
S & F in repair Bell ding dong type, one way, 240 volts, AC, ISI marked complete all as specified and directed

5

-

-

... More
S & F in repair ceiling rose in replacement surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked complete all as specified and directed.

40

-

-

... More
S & F in repair stright/Angle bulb holder pvc body complete.Make: Anchor, kolors, material to be supplied as per demand of qty is ordered by Engineer -in- charge as per site requirement complete all as specified and directed.

20

-

-

... More
S & F in repair in Stepped/socket type electronic fan regulator heavy duty typeA/C 240 V complete all as specified and directed.

5

-

-

... More
S & F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.

5

-

-

... More
S & F in repair TPN DBs Vertical type 4 way DB 415 volt with provision for FP MCB as incomer and MCB SP as outgoing complete all as specified and directed.

2

-

-

... More
S & F in repair sheet metal enclosure for single pole and neutral 12 way DB 240 voilts, 100 Amp rated bus bar complete all as specified and directed.

2

-

-

... More
S & F in repair sheet metal enclosure for single pole and neutral 08 way DB 240 voilts, 100 Amp rated bus bar complete all as specified and directed.

4

-

-

... More
S & F in repair sheet metal enclosure for single pole and neutral 04 way DB 240 voilts, 100 Amp rated bus bar complete all as specified and directed.

4

-

-

... More
S & F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps complete all as specified and directed.

2

-

-

... More
S & F in repair MCB SP 5 to 32 Amps 10KA 'C' curve and240 volts current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed

30

-

-

... More
S & F in repair MCB SPN 32 Amp, 10 KA, 240 Volts complete all as specified and directed.

10

-

-

... More
S & F in repair MCB SPN 40 to 63 Amp 240 Volts complete all as specified and directed.

8

-

-

... More
S & F in repair MCB SP & N up to 100 Amp 240 Volts complete all as specified and directed.

2

-

-

... More
S & F in repair MCB four pole up to 80 Amp 415 Volts complete all as specified and directed.

2

-

-

... More
S & F in repair MCB (Four pole) 100 Amp 415 Volts complete all as specified and directed.

1

-

-

... More
S & F in repair MCCB 100 Amp 16 KA complete all as specified and directed.

1

-

-

... More
M&L in repair for Earthing complete as per electrical plate NO.3 of MES SSR Part I with galvanised steel plate earth electrode 600 mm x 600mm x 6 mm burried directly in ground in a pit of depth not less than 2.25 metre below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and incl galvanised iron or steel earth lead wire 4 mm dia by mneans of bolts, nuts, check nuts and washers of galvanised iron or steel earthing wire protected by galvanised iron or steel pipe 15 mm dia light grade and connected to main switch board or main control board watering pipe shall be 20 mm dia GI medium grade incl excavation and earth work in any type of soil, PCC pit, CI Frame, RCC covers complete all as specified and directed.

1

-

-

... More
S & F in repair PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm x 50 mm complete all as specified and directed.

1

-

-

... More
All as per serial item No. 188 above but for size 175x100x50 mm deep complete all as specified and directed.

2

-

-

... More
All as per serial item No. 188 above but for size 200x150x50 mm deep complete all as specified and directed.

2

-

-

... More
All as per serial item No. 188 above but for size 250x200x50 mm deep complete all as specified and directed.

2

-

-

... More
All as per serial item No. 188 above but for size 350x200x50 mm deep complete all as specified and directed.

2

-

-

... More
S & F in repair single phase electronic meters temper proof LCD display with polycarbonate cover 230 V,10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH Class 1 complete all as specified and directed.

1

-

-

... More
S & F in repair of PVC conduit size 25mm Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories including chase cutting such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed

70

-

-

... More
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed

50

-

-

... More
S & F in repair LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete complete all as directed by Engr-in-charge.

12

-

-

... More
S & F in repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light 20W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed by Engr-in-charge.

70

-

-

... More
S & F in repair LED lights fitting 1x 20W, 220V, AC LED Batten with Opal Diffuser, IP20, Inbuilt Motion Sensor based Auto Dim/Brightness decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed by Engr-in-charge.

10

-

-

... More
S & F in repair LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, including 600mm long bracket with fastner bolt nut and washer for fix in wall complete all as specified and directed.

30

-

-

... More
S & F in repair LED light fittings small 6 watt round/square type white/yellow complete with choke/driver complete all as specified nd as directed Make : Hallonix/C&S/Orient/Havells/Phillips/Surya

10

-

-

... More
S & F in repair recess mounted down lighter 12 Watts complete all as specified and directed yellow/white AS Per Sample complete all as specified and directed

20

-

-

... More
S & F in repair LED bulb Lamp 09/10 Watts Retrofit B22 holder type base wth polycorbonate diffuser and alluminiun heat sink complete all as specified and directed.

50

-

-

... More
Taking down fan, sealing cable end,dismantling blades and removing fan and blades to E/M store complete all as specified and directed

20

-

-

... More
S & F in repair of storage type water heater from wall by disconnecting the electric connection and water inlet/outlet connection from main and repairing the water heater storage type capacity 25 ltrs of any type and make, checking the serviceablity of all parts such as inner vesser, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of unserviceable parts and assembly completet (considered as one unit) and installing and testing the same as per the direction of Engineer-In-Charge.

8

-

-

... More
All as per serial item No 204 above but for capacity 50 ltrs complete all as specified and directed.

2

-

-

... More
S & F in repair of heating elements, 1.5/2 KW any type any size ISI mark 230 volts complete all as specified and directed.

10

-

-

... More
S & F in repair of thermostat immersion point type 15 Amps, 230250 volts/AC ISI marked complete all as specified and directed.

10

-

-

... More
S & F in repair ,stainless steel flexible conneciton pipe with brass check nuts complete as per site requirement all as specified and directed by Engineer-In-Charge.

5

-

-

... More
S & F in repair of indicator lamp assembly for geyser complete all as specified and directed by Engr-In-Charge.

5

-

-

... More
S & F in repair 15 Amp plug top complete all as specified and directed.

15

-

-

... More
S & F in repair earth industrial plug top for socket for industrial socket metal glad suitable for 16 Amps metal glad MCB DB complete all as specified and directed.

2

-

-

... More
S & F in repair industrial socket metal glad suitable for 16 Amps 240 volts metal glad MCB DB complete all as specified and directed.

2

-

-

... More
S & F in repair 4 sq mm 3 core flexible copper cable for maintenance of geyser, and cooling appliances. (In Role of 90 RM) complete all as specified and directed.

35

-

-

... More
S & F in repair syphon assembly suitable for 25/50 ltr geyser complete including nuts and washer complete all as specified and directed.

5

-

-

... More
S & F in repair geyser brass tank for 25/50 ltr geyser complete including nuts, washer, glass wool etc complete all as specified and directed.

2

-

-

... More
S & F in repair 23/.0076 sq mm 2 core flexible copper cable for maintenance of light/ fan etc complete all as specified and directed.

90

-

-

... More
M&L for attending complaint of ceiling fan/exhaust fan/air circulator/ cabin fan such as hanging/dismantling/loose connection etc complete all as specified and directed

70

-

-

... More
S & F in repair of capacitor 4 MFD suitable for any make, type & sweep ceiling fan, exhaust fan, cabin fan & pedestal fan of complete all as specified and directed.

20

-

-

... More
S & F in repair capacitor of 2.5 MFD of ISI marked complete all as specified and directed.

15

-

-

... More
M & L in repair of rewinding of ceiling fans 1200/1400mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed

15

-

-

... More
M & L in repair of rewinding of Exhaust fan 300 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed

5

-

-

... More
M & L in repair of rewinding Exhaust fan 450 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed

5

-

-

... More
M & L in repair of fan bearing 6201/6202 of ceiling fan of any capacity any size all as specified and directed Note: Replacement of bearing to be carried out at E/M complaint cell at LMS only exceptional case where lathe work is required then only fan to be taken at workshop.

5

-

-

... More
M & L in repair of bearing/bush of exhaust fan/cabin fan/air circulator of any capacity any size all as specified and directed. Note: Replacement of bearing to be carried out at E/M complaint cell at LMS only exceptional case where lathe work is required then only fan to be taken at workshop.

5

-

-

... More
S & F in repair exahust fan blade 300mm sweep with locking nut complete all as specified and directed

3

-

-

... More
S & F in repair ceiling fan blade 1200mm/1400 mm complete all as specified and directed.

5

-

-

... More
Dismantling and taking out existing unserviceable geyser and deposited to E/M store yard complete all as specified and directed

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.