Military Engineer Services Tender
View complete overview of Manipur MES Tender
Costs
EMD
₹ 73,520Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_639626_1Bid Award Id
ViewTender No
8566/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PROVN OF WAITING SHED (BUS SHED) AT MIL HOSP AND ADDN/ALTN TO REFUSE BINS AT VARIOUS LOCATIONS AT LEIMAKHONG MIL STN
PROVN OF WAITING SHED (BUS SHED) AT MIL HOSP AND ADDN/ALTN TO REFUSE BINS AT VARIOUS LOCATIONS AT LEIMAKHONG MIL STN
PROVN OF WAITING SHED (BUS SHED) AT MIL HOSP AND ADDN/ALTN TO REFUSE BINS AT VARIOUS LOCATIONS AT LEIMAKHONG MIL STN
BOQ Items
S&F Pre-Painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed.
480
-
-
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip, straight flashing etc fixed with self tapping screws complete all as specified and directed.
28.2
-
-
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
25
-
-
S & F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc .Fe 410-gde -E250 quality-A complete all as specified and directed.
1500
-
-
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to beprepared for hangingor slidingwith and including either hooksand hinges or steel hangingdoor fittings (exclusive of steelsheeting or other covering,running rails and guides) and hanging; also fastening andfixing complete all as specified & directed.
1000
-
-
S&F Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. complete all as specified and directed.
20
-
-
S&F framed iron work conforming to Fe-290 Gde-E-165 for portions framed and hung as gates, including pintle hinges, stops, handmade sliding bolts, etc complete all as specified and directed.
20
-
-
M&L for preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed.
250
-
-
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles and removing unserviceable materials from site of work complete all as specified and directed.
38
-
-
M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed.
50
-
-
M&L for rendering (10mm+5mm) thick in two layer on other than fair faces of brick work in cement mortar (1:4) using water proofing compound @2% by weight of cement as per manufacture instruction and finishing the surface even and smooth without using extra cement complete all as specified and directed.(Using Dimapur Sand)
[Note: WPC will be measured and paid separately)
300
-
-
M&L for preparation of new plastered surfaces applying two coats of cement base paint over a coat primer complete all as specified and directed.
300
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
5
-
-
S&F Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile including 10mm thick cement mortar backing in CM (1:4) as backing coat to receive tiles complete all as specified and directed.
203
-
-
Demolition of cement concrete un-reinforced of any description and any position not otherwise specifically provided for complete all as specified and directed.
11
-
-
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, including screed bed 20mm thick in CM 1:6 complete all as specified and directed.
105
-
-
M&L for 75mm thick cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in plinth protection including finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.(Using dimapur sand)
175
-
-
M & L for forming 20mm thick expansion joints 100 mm thick of concrete slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and directed
8
-
-
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft and loose soil complete all as specified and as directed.
200
-
-
Removing excavated material to a distance exceeding 250 m but n. exc. 500 m and diposited where directed by Engineer-in-Charge
30
-
-
M&L hardcore of gauge n exc 63mm, broken stone or boulders deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface completed all as specified and directed.
10
-
-
M&L 75mm thick cement concrete type D-2 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
200
-
-
M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick set jointed with grey cement and pigments and pointed in neat cement slurry in floors including 15mm thick sreed bed in CM 1:4 complete all as specified and directed.
200
-
-
S&F PVC SWR pipes 160 mm bore single socketed in any length with rubber ring joint laid in trenches or in floors as in waste / soil pipe complete all as specified and directed.
32
-
-
S&F Mild steel 0.80mm thick plain sheet in steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. complete all as specified and directed.
30
-
-
M&L for preparation of old treated surface of wall and applying one coat of cement base paint on wall complete all as specified and directed.
55
-
-
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and getting out in soft/loose soil complete all as specified and directed.
20
-
-
M & L for PCC 1:2:4 type B2 using 40mm graded aggregate as in walls or retaining walls, any thickness, size or shape including pilasters,buttresses columns, pillars boundary pillars and posts (including caps and bases) complete all as specified and directed
2.5
-
-
S&F 0.63mm plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip, wall cladding and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
10
-
-
S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with coach screws and washers in roof, wall etc complete all as specified and directed.
20
-
-
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240.complete all as specified and as directed.
850
-
-
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sucnk) forming holes with any attachement Fe 410W (Gde-E-250) complete all as specified and directed.
50
-
-
M&L for structural steel work in Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410-W (Grade E-250) quality-A complete all as specified and as directed.
1192
-
-
S&F PVC SWR pipes 110 mm bore single socketed in any length with rubber ring joint fixed to wall with steel clamps and laid in trenches or in floors as in waste / soil pipe weight of pipe not less than .70Kg/Rm complete all as specified and directed.
8
-
-
S&F for 110 mm PVC (SWR) bends any radius complete all as specified and directed.
2
-
-
Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated 1100 volts grade and unsheathed, multi-stranded, copper conductor single core cable through and including concealed wiring 20 mm pvc rigid conduit all fixing accessories and suitable including 1.6 mm thick size sunk MS pressed steel terminal modular box for mounting modular switches,sockets and regulator etc including multi-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc complete all as specified and directed for following :- (Colour code to be followed) (a) One light point controlled by one, one way switch
9
-
-
One ceiling/exhaust fan point controlled by one, one way switch
2
-
-
All as per item No. 38.00 here-in-above but with cable size 2.5 Sqmm for one 5 pin, 15 Amps socket outlet on independent board/400 Watt flood light and multistrand insulator copper earth continuity conductor of size 2.5 Sqmm complete all as specified and directed.
4
-
-
S&F modular switch piano, 6 Amps, single pole, one way complete all as specified and directed.
11
-
-
S&F modular switch piano, 16 Amps, single pole, one way complete all as specified and directed.
4
-
-
Supply and fixing modular Socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module complete all as specified and directed.
4
-
-
S&F Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed.
11
-
-
S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 12 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed.
1
-
-
S&F MCB single pole 06 to 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
4
-
-
S&F MCB single pole and neutral upto 63 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
1
-
-
S & F LED light fitting 1x20 Watt , 220 V , AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
9
-
-
M & L for submain wiring with single core 4.0 sqmm PVC FRLS insulated unsheathed cable multi stranded copper conductor drawn through and inclduing PVC casing / capping of suitable size with all fittings and fixing accessories on roof , walls, ceiling etc including 4.00 Sqmm PVC insulated unsheathered one core multistranded copper condutor earth wire complete all as specified and directed. (Note : Two run of single core cable and one run earth wire will be measured as one length)
35
-
-
M&L for circuit main wiring using two single core 1.5 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/ PVC Conduit or in existing Concealed Conduit (as required & directed by Engr-in-charge) accessories like bends, tee,etc fix on wall and ceiling and connceting to earth dolly and including 1.5 sqmm earth wire, PVC insulted & Unsheathed complete all as specified and directed.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements