Manipur State Rural Roads Development Agency Tender

View complete overview of Manipur MSRRDA Tender

Manipur State Rural Roads Development Agency - MSRRDA Tender

Works
Eprocure
Opening Date17 May 2018
Closing Date1 Jun 2018
Tender Amount₹ 5,97,66,000 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position Plain Cement Concrete of Grade M 15 in leveling course below Pilecap foundation complete as per drawings and Technical Specification section 1500,1700

35.5

-

-

... More
Providing and laying M-30 grade Reinforced Cement Concrete in pile cap complete as per Drawing and Technical Specifications.Ref. to Technical specification 1500,1700 & 2100 .

611.07

-

-

... More
Bored cast-in-situ M30 grade R.C.C. Pile (1.2m dia for Bridge) excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m all complete as per Technical specifications and as directed by the Engineer-in-charge.

-

-

-

... More
Boring in soil

1000

-

-

... More
Supplying, fitting and placing Fe 500 HYSD/TMT bar reinf. in foundation complete as per drawing and Technical Specifications Ref. to Technical specification 1600 & 2200 .

-

-

-

... More
Pile cap

64.18

-

-

75.2

-

-

... More
Permanent Steel Liner (6mm thk) in Piles (MS-Gr 250)

54

-

-

... More
C) Substructure

-

-

-

... More
Providing and laying M-30 grade Reinforced Cement Concrete in Sub structure complete (Pier & Pier Cap) as per Drawing and Technical Specifications.Ref. to Technical specification 1500,1700 & 2100 .

135.98

-

-

... More
Supplying, fitting and placing Fe 500 HYSD/TMT bar reinforcement in substructure complete as per drawing and Technical Specifications . Ref. to Technical specification 1600 & 2200 .

13.74

-

-

... More
D) Superstructure

-

-

-

... More
Providing and Placing Reinforced Cement Concrete in super-structure as per drawing and Technical Specififications Sections 1500, 1700 & 2300.

-

-

-

... More
M30 RCC Deck Slab

73.6

-

-

... More
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

-

-

-

... More
a) RCC Deck Slab

12.6

-

-

... More
Providing steel R.S.Js/built-up steel sections including cutting, welding/rivetting, hoisting, fixing in position for composite girders with shear connectors complete with painting as per drawing and technical specifications Clause 1205.6

-

-

-

... More
Structural steel (GR 250 ) for Composite span

73.9

-

-

... More
Shear Studs (25mm dia 100mm height)

-

-

-

... More
Main Beam ( 25dia 100mm height - characteristic yeild strength 385Mpa with min 18% elongation and characteristic tensile strength 495MPa)

1500

-

-

... More
Cross Beam ( 25dia 100mm height - characteristic yeild strength 385Mpa with min 18% elongation and characteristic tensile strength 495MPa)

126

-

-

... More
Bolts for connections (M24-8.8 grade) Cross Beam

144

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8

120

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing

96

-

-

... More
Providing and fixing of Strip Seal Joints as per MOST specifications and tender clauses in all respect as per detailed drawing for carriageway.

25.6

-

-

... More
Supplying, fitting, and fixing in position true to line and level sliding plate bearing wth PTFE surface sliding on stainless steel complete as per drawing and technical specification and BS: 5400, sections 9.1 & 9.2 (for PTFE) and clause 2004 of MORTH specifications

-

-

-

... More
Bearing

-

-

-

... More
a) Pot PTFE Bearing

-

-

-

... More
Free Bearings (85 MT) 6nos

510

-

-

... More
Guided Bearings (85 MT) 6nos

510

-

-

... More
Fixed Bearings (85 MT) 6nos

510

-

-

... More
Wearing Coat

-

-

-

... More
a) Providing and laying 65 mm thick Bituminous wearing coat (40mm BM + 25mm BC) as per technical specification and as directed by the Engineer.

19.25

-

-

... More
b) Prime Coat on top of Deck Concrete

275

-

-

... More
c) Water Proofing Layer on top of Prime Coat (below WC)

275

-

-

... More
Providing and fixing Drainage Spouts complete as per drawing and Technical specification.Ref. to Technical specification 2705 along with clamps 150mm dia rigid PVC downtake and runner pipe as per IS 4985, Class II including joining with drainage spout pipe , providing couplers, bends etc., complete as per drawings..

11

-

-

... More
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3

120

-

-

... More
Providing and laying PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification. Ref. to Technical specification 2700.

4.95

-

-

... More
Providing and Laying Reinforced cement concrete of Grade M-30 in approach slab including reinforcement Fe500 and formwork complete as per drawing and Technical specification. Ref. to Technical specification 1500,1600,1700 & 2704 .

-

-

-

... More
Concrete

14.85

-

-

... More
Reinforcement

1.11

-

-

... More
Tar paper below approach slab

49.5

-

-

... More
Initial Load Test icluding additional pile with reinforcement for 2.5 times the design load specified in Drawings

-

-

-

... More
a) Initial Load Test ( design Load - 140 mt )

1

-

-

... More
Routine pile load test on working pile for a test load of 1.5 times the design load specified in Drawings.

-

-

-

... More
a) Routine Load test ( design Load - 140 mt )

2

-

-

... More
c) Pile Intergrity test ( LST - by Pulse Echo )

40

-

-

... More
Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site

-

-

-

... More
b) Directional arrows and letters

33

-

-

... More
Painting for Superstructure

-

-

-

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701

879.23

-

-

... More
Setting Out

-

-

-

... More
Construction of Job pillers as per Fig. 1600.1 (d) and Technical Specification Clause 1602.4

1

-

-

... More
Construction of RCC guide posts of 250 mm dia M15 grade cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2

4

-

-

... More
Providing and Fixing 'Logo' of PMGSY Project

-

-

-

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

1

-

-

... More
Providing and Fixing Citizen information Board of PMGSY Project(Steel Tube)

-

-

-

... More
Providing and fixing of Citizen's Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5m size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frames of the plates will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

1

-

-

... More
Providing and Fixing PMGSY Logo Board at starting point(Steel Tube)

-

-

-

... More
Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing.One plate of 1.6mm thick with MS flat 25mm x 5mm size on back on centre. The topmost diamond plate & mid. plate will be welded to 75mmx75mm of 12 SWG steel plate tube posts & duly embedded to CC 450mm x 450mm x 600mm below GL. Lettering and printing etc. will be with ready mixed synthetic enamel paint of superior.

1

-

-

... More
Retro-reflectorised Traffic Signs

-

-

-

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801

-

-

-

... More
a) 600mm equilateral triangle

2

-

-

... More
Compacting original ground supporting subgrade

-

-

-

... More
Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.

347.4

-

-

... More
Construction of Subgrade and earthen shoulder

-

-

-

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.

65.14

-

-

... More
Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408.

-

-

-

... More
(i) Using naturally occuring gravel

164.05

-

-

... More
WBM Grading 3

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.

-

-

-

... More
A) By Manual Means

61.52

-

-

... More
Prime coat : Low porosity

-

-

-

... More
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502

820.25

-

-

... More
Tack Coat

-

-

-

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.

820.25

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder

-

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.

-

-

-

... More
Case-I By Manual Means

-

-

-

... More
(i) Bitumen(S-90)

820.25

-

-

... More
Seal Coat

-

-

-

... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510

-

-

-

... More
Case - II : Type B

-

-

-

... More
(i) Bitumen(S-90)

820.25

-

-

... More
Maintenance component for 5(five) years after construction ( not to be quoted yearwise)

-

-

-

... More
1st year: (INR) 284602.13

-

-

-

... More
2nd year: (INR) 426903.2

-

-

-

... More
3rd year: (INR) 569204.26

-

-

-

... More
4th year: (INR) 711505.33

-

-

-

... More
5th year: (INR) 853806.39

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.