Manipur State Rural Roads Development Agency Tender

View complete overview of Manipur MSRRDA Tender

Manipur State Rural Roads Development Agency - MSRRDA Tender

Works
Eprocure
Opening Date14 Sep 2020
Closing Date9 Oct 2020
Tender Amount₹ 4,51,29,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Scarifying Existing Granular Surface to a Depth of 50 mm by Manual Means Scarifying existing granular surface to a depth of 50 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4.

12000

-

31.02

... More
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.

4288.05

-

494.37

... More
Compacting original ground supporting subgrade Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.

7124.76

-

49.95

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 i) 5th Kilometer Stone (Precast)

1

-

4803.91

... More
ii) Ordinary Kilometer Stone (Precast)

5

-

2844.75

... More
iii) 200 m stone (precast)

24

-

745.01

... More
Providing and Fixing 'Logo' of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

1

-

18526.43

... More
Providing and Fixing of Citizen Information Board of PMGSY Project (Steel Tube) Providing and fixing of Citizen's Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5m size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frames of the plates will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

1

-

21914.81

... More
Providing and Fixing Maintenance Information Board of PMGSY Project Providing and fixing of maintenance Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5 mm size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the plates will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enamelled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing clause 1701 and Annexure 1700.1

1

-

21863.83

... More
Traffic Signs/Retro-reflectorised Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. a) 600 mm dia circle

3

-

2986.54

... More
b) 600 mm equilateral triangle

3

-

2836.29

... More
Providing and Fixing PMGSY Logo Board at starting point (Steel Tube) Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing. One plate of 1.6mm thick with MS flat 25mm x 5mm size on back on centre. The topmost diamond plate & mid. Plate will be welded to 75mm x 75mm 0f 12 SWG steel plate tube posts & dully embedded to CC 450mm x 450mm x 600mm below GL. Lettering and printing etc. will be with ready mixed synthetic enamel paint of superior.

2

-

10220.11

... More
Direction and Place Identification signs upto 0.90 Sqm Size Board A. Retro-reflectorised Traffic Signs Providing and erecting direction and place identification retro-reflectorised sheeting vide clasue 1701.2.3., fixed over aluminium sheeting 2mm thick with area not exceeding 0.90 sqm supported on a mild steel angle iron posts 75 x 75 x 6 mm firmly fixed to the gorund by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600mm, 600mm below ground level as per approved drawing and technical specifications Clasuse 1701

1

-

4120.51

... More
Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method. Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. ii) For Grading II Material

4166.2

-

866.92

... More
WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405. A) By Manual Means

1656.41

-

2528.75

... More
WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405. A) By Manual Means

1656.41

-

2899.31

... More
Prime Coat:Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502.A) By Manual Means

22047.6

-

33.07

... More
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. A) By Manual Means

22047.6

-

12.23

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case-I By Manual Means (i) Bitumen(S-90)

22047.6

-

206.24

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510.Case II : Type B (By Manual means)(i) Bitumen(S-90)

22047.6

-

65.68

... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. II) By Manual Means (C) Reinforced Cement Concrete

9.38

-

1614.84

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. (B) Above 600 mm to 900 mm dia Hume pipe

120

-

335.2

... More
CONSTRUCTION OF PUCCA LINED DRAIN WORKS(100m)

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary Soil (i) Upto 3m depth.

89.25

-

381.78

... More
Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10

13.5

-

6456.63

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. III) Random Rubble Masonry (ii) In 1:4 Cement Mortar

36

-

5052.53

... More
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204

180

-

231.56

... More
Construction of 1.50 m span RCC Slab Culvert 4.63 ht.(7nos)

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary Soil (i) Upto 3m depth.

794.36

-

381.78

... More
Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:6

41.23

-

6456.63

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 i) PCC M 15 i) Nominal mix (1:2.5:5)

335.79

-

6777.56

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II. RCC Grade M 25

26.46

-

9089.16

... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

2.64

-

50663.56

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

112

-

276.54

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

147.97

-

981.95

... More
Construction of 2.00m span slab culvert (Height - 3.44m).(1no)

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material I) Ordinary Soil i) upto 3m depth

189.45

-

381.78

... More
Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:6

15.67

-

6456.63

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 i) PCC M 15 i) Nominal mix (1:2.5:5)

77.01

-

6777.56

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II. RCC Grade M 25

5.12

-

9089.16

... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

0.49

-

50663.56

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

32

-

276.54

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

45.41

-

981.95

... More
Construction of 3m span RCC Slab Culvert (Ht-3.70m)(2nos)

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material I) Ordinary Soil i) upto 3m depth

307.9

-

381.78

... More
Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:6

21.7

-

6456.63

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 i) PCC M 15 i) Nominal mix (1:2.5:5)

123.5

-

6777.56

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II. RCC Grade M 25

18.28

-

9089.16

... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

1.82

-

50663.56

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

60

-

276.54

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

46.8

-

981.95

... More
Construction of 10.00 m span RCC Slab Culvert (ht-6m.)(1no)

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary Soil (i) Upto 3m depth.

699.19

-

381.78

... More
(ii)3 m to 6 m depth

474.32

-

453.37

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8. I)Granular material

391.17

-

949.91

... More
Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:6

25.89

-

6456.63

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 i) PCC M 15 i) Nominal mix (1:2.5:5)

316.96

-

6777.56

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. (I) R.C.C grade M 20 (i) For nominal mix 1:2:4

9.29

-

9089.16

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II. RCC Grade M 25

50.4

-

8520.34

... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

4.31

-

50663.56

... More
Drainage spouts complete as per drawing and technical specifications Clause 1209

6

-

2004.21

... More
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3

23.6

-

2716.28

... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3

5.04

-

13387.98

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

36

-

276.54

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

129.7

-

981.95

... More
Construction of Retaining Wall : Height 3.5 m(10nos)

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material I) Ordinary Soil i) upto 3m depth

1205.4

-

381.78

... More
Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:6

54.5

-

6456.63

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 III) Random rubble masonry ii) In 1:4 cement mortar

554.8

-

5422.63

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

170

-

276.54

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

150

-

981.95

... More
Pointing with cement mortar (1:3) on brickwork as per drawing and technical sepecification clauses 613.3 and 1204

536

-

84.74

... More
Maintenance component for 5(five) years after construction (not to be quoted yearwise) in INR:

-

-

-

... More
1st year 455800

-

-

-

... More
2nd year 683700

-

-

-

... More
3rd year 1139500

-

-

-

... More
4th year 1139500

-

-

-

... More
5th year 1139500

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.