Western Railway Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Western Railway - WR Tender
Machinery and Tools
Metals and Non-Metals
Ireps
Opening Date30 Dec 2024
Closing Date21 Jan 2025
Tender Amount₹ 1,07,71,266.31
Costs
EMD
₹ 2,03,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Signaling Work In Connection With Ccg-vr Trr(p)- 17.219 Tkm &tsr(p) - 63.968 Tkm In Mumbai Division Western Railway.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
W_829_2024_SG_WA-MUMBAI CENTRAL DIVISION-S AND T/WESTERN RLYTender No
W_829_2024_SG_WATender Authority
Western Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
RAIL TWIST ADAPTOR FOR 7.2MM DRILL FOR 19 MM suitable for battery operated rail drill machine make Eibenstok Positron or similar
8
674
5399.68
... More
RAIL TWIST ADAPTOR FOR 13MM DRILL FOR 19 MM suitable for battery operated rail drill machine make Eibenstok Positron or similar
8
850
6801.52
... More
RAIL TWIST ADAPTOR FOR 16MM DRILL FOR 19 MM suitable for battery operated rail drill machine make Eibenstok Positron or similar
8
1152
9222.88
... More
RAIL TWIST DRILL DIA 7.2MM FOR ADAPTOR 19 MM suitable for battery operated rail drill machine make Eibenstok Positron or similar
10
1045
10454.8
... More
RAIL TWIST DRILL DIA 13MM ADAPTOR 19 MM suitable for battery operated rail drill machine make Eibenstok Positron or similar
10
2820
28202
... More
RAIL TWIST DRILL DIA 16MM ADAPTOR 19 MM suitable for battery operated rail drill machine make Eibenstok Positron or similar
10
3229
32296.6
... More
SS taper pin(stud) 15mm dia/ 65mm long with one plain washer,one spring washer & two nuts for siemens AFTC as per drg no: DRM/SG/942
640
152
97299.2
... More
Supply of Nylon Insulation for Thick Web point machine, consist of Insulating. (1) plate - 02 Nos . as per RDSO Drg. No-S-34041(2) Nylon Insulation bush-8 Nos , as per RDSO Drg. No-(a) S- 32199-04 Nos . (b) S-8813-04 Nos , (3) Nylon Insulation Washer 08 Nos, as per RDSO Drg. No. (a) S- 8640/1-04 Nos . (b) S-8640- 04 Nos. 2) Through rod Insulation = 1 no Bush(RDSO Drg No. CSE- 11 8640/1, 2 nos Washers (CSE8640/2) 3) Lock slideInsulation -2 nos Bushes (RDSO Drg No- CSE 8640/A)4 nos Washers (RDSODrg No. CSE-8640/1). 4) Detection slide insulation =2 nos Bushes (RDSO Drgno. 8641/A), 4 nos Washers (RDSO Drg No-8640/1). 5) SSD Insulation Rod =1no. Plate (RDSO Drg No S325/M), 2 nos . Bushes (RDSO Drg No-T10372), 4nos. Washers (RDSO Drg No T-10371). 6) SSD Insulation in Rail 1 no . Washer(RDSO Drg No washer : S8640) 1 no Bush (RDSO Drg No S8641/A) 7) Pbracket Insulation :- Insulation Plate 01 (RH) RDSO Drg No: S3265 Insulation Plate = 01 No (LH) RDSO Drg no. S3266 , Insulation Bushes=04 nos. RDSO Drgno S23199 Insulation Washer : 04 nos . RDSO Drg no. S8640.
20
995
19918.4
... More
Point insulation Complete set as per RDSO Specification IRS: S-40/84 for Switch bracket, Split-Stretcher bar & Gauge tie plates (52 Kg/60Kg asper site requirement)
50
1345
67296.5
... More
Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia.0.2mm), as per IRS 76/89 (Amd3).
3
5548
16645.62
... More
Battery operated Impact wrench mainly used to easily open the jammed/rusted nuts of Point, signal units and other bolts in plain track etc. asper (No. TM/SM/IW dated 09.01.2014) (Rev 02 of 2022) , ISO 28927-2: 2009(Amendment-01-2017)
2
59000
118000
... More
Copper lug 25 sqmm suitable for siemens AFTC lead wire for TU,make Dowels,braco or similar
240
9
2337.6
... More
Copper lug 25sq mm,16mm dia holes suitable for siemens AFTC center connection with double holes, Make dowels, braco or similar
80
138
11116.8
... More
Copper lug 25sq mm,8 mm dia holes suitable for siemens AFTC center connection with double holes, Make dowels, braco or similar
80
117
9404.8
... More
Clamp with deflector plate and hardware for fixing the Transmitter and Receiver Coil suitable for MSDAC
80
7080
566400
... More
Switch plate Lubricant, High Performance Slide Chair Lubricant With Excellent 19 Corrosion Protection Colour - Black,) Appearance Semi Fluid,Thickener Type Inorganic, Penetration 450-470, 4 Ball Weld Load 315kg, 4 BallWear Scar 0.60mm, Temperature Range -30C To 80C, Packing of 12.5 Kg PailBox. 20
175
3540
619500
... More
Earth Electrodes as per Drawing No.CSTE/6091
10
2798
27989.9
... More
MS galvanized Flat Plate Strip (Specification no. 226 STD or latest 35 mm x 6 mm thick for earth connection to Signal post, L/Box etc.
1000
138
138350
... More
ALLUMINIUM ANGLE OF SIZE (FROM 25 X 25 X 6 MM TO 50 X 50X6 MM ) ALONG WITH ACCESSORIES & TRANSPORTATION
75
450
33750
... More
ALLUMINIUM ANGLE OF SIZE (FROM 25 X 6 MM TO 50 X 6 MM )ALONG WITH ACCESSORIES, HEAT SHRINK SLEEVES & TRANSPORTATION
25
470
11750
... More
Supply of Extension Card siemens make MSDAC
5
12289
61448.5
... More
Disconnect Terminal Block, Screw less type, as per RDSO Spec No. 26 RDSO/SPN/189/2004 or latest.(i) Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decidedby Engineer-in-Charge. (Preferably In Blue, Red & Grey Colors in the ratio of1:2:3). Preferably approved by Railway before supply.
300
58
17559
... More
Disconnect Terminal Block, Screw less type, as per RDSO SpecNo. RDSO/SPN/189/2004 or latest. (ii)Supply of End plate for above item(I)2.5mm/0.091 in thick as per site requirement.
-
-
27
... More
Disconnect Terminal Block, Screw less type, as per RDSO SpecNo. RDSO/SPN/189/2004 or latest. (iii) Supply of End Stopper for above item(I) 10mm/0.0394 in width as per site requirement.
75
10
814.5
... More
Disconnect Terminal Block, Screw less type, as per RDSO SpecNo. RDSO/SPN/189/2004 or latest. (iv) Supply of Carrier Rails for above 35mmx 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement.
5
113
569.4
... More
Crimping pliers PEW12 with Die Set ( Capacity- 16 mm2 /25mm2 ) Dimension - 250 x 108 x 43 mm Make:- Rennsteig, DMC ,Molex,Amphenol
1
22712
22712.64
... More
Cable Knife System 4-70 with automatic blade protection and cable bracket for stripping round cables, Make- Jokari-70000, Weidmuller,Knipex, Phoenix contact
1
4413
4413.2
... More
Cable cutter (SWA cable) Capacity (diameter)- 45 mm/380 mm2with precision blades Make:- KNIPEX , Gedore, Sthwille, Greenlee 33
1
45548
45548
... More
Contact Alu-Plus syringe 249 series for Wago terminals, Anti rusting Pest (20 ml) 34
20
161
3233.2
... More
Printed PVC Ferrule FOR CTR / Location Box And Junction Box 35
5000
5
27750
... More
Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. (The 37 manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified.
40
1912
76488
... More
Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 50 mm outer dia, & 38 mm inner dia. (The 38 manufacturers,suppliers must produce valid IS license and should be certified under ISO 9000and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. 39
20
444
8896
... More
L sensor clamp for MSDAC
80
826
66080
... More
Silicone Gel based cable Jointing kit suitable for cable Jointing of Signalling cable of various size, having dielectric strength > 20KV/mm, NonToxic, low viscosity, Flamability point > 200 C, Reentrable, Long storage life Make RAYTECH or Similar. Cable Size 12 x 1.5 Sq. mm
10
4855
48550.3
... More
Diagnostic Terminal :Multi section Portable operator console for onsite programming of Axle Counters as per technical requirement.
1
98280
98280.68
... More
Portable work station for Data input & configuration with necessary software/programs /Accessories, simulation and functional testing,diagnostics and trouble shooting and commissioning of 3 EI system. Suitable table and chair of reputed make shall be supplied by the contractor. Note: The specification of portable work station shall be as per Technical specification or higher version as approved by Engineer In-Charge. All the required software should be uploaded Licensed CD should be given along with software.
2
132660
265321.82
... More
As and when required by the Engineer in charge arranging/providing of labors for 3 various safety related works such as protection of track etc. with contractor's T&P, equipment, hand signal flags, spanners, hammers,etc. as per specification special conditions and detailed scope of work as furnished in the tender and directed by the engineer incharge.
800
649
519768
... More
Skilled man power to be provided by contractor for Engg. JCBs working to provide marking & supervisory work for the S&T cables during digging work by JCB's and repairing /restoring/jointing of cables, if damaged Cables & Joints Material will be provided by railway. While 4 Chuna marking will be done by his/her Chuna will provided by contractor information for deputing skilled man power for above work will be provided by Railway Engineer incharge before 24 hours from commencement of digging by JCBs. They will check cablesroute by Cable route tracer and will do chuna marking and will show the cables(on rough sketch) available in a small length approximate 50-100 meters of digging. Note: Minimum two man will be provided at a time including Cable jointer, they will stay whole time during JCB digging work. (The CV to be got approved by Railway).
700
707
495096
... More
Termination of outdoor cables, main cables laid in location boxes,Cable termination rack etc at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends 5 of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as perinstructions of Rly engineer at site.
300
23
7110
... More
Disconnecting the S bond and alpha bond from the rail by cutting rivets or removing the bolts etc removing them away from track and reconnect the same later on. As per instruction of railway site incharge. The tapper pin,rivets required for reconnecting the bonds will be supplied by railway.
-
-
6
... More
Disconnecting the AFTC lead wire from the rail removing them away from track and 7 reconnect the same later on. The bond plates tapper pins required for refixing the track lead wire would be provided by railway. Removal and refixing of all the track lead wires connected to one unit would constitute one set.
30
252
7567.8
... More
Removing of existing DAC censer/AWS track magnet for replacing clamp assembly , The work shall be done as per instructions of Rly engineer at site
20
76
1523.2
... More
Fixing of DAC censer/ Tx-Rx coils/TM with clamp assembly, The work shall be done as per instructions of Rly engineer at site
20
205
4110.6
... More
Placing of DWC/GI/ RCC / HDPE pipe in trench for track / road crossing protruding equally outside the rail/road edge on either side.
-
-
10
... More
Drilling of holes of different sizes in rails7.2mm/12mm/16mm/22mm, as per instructions of rly site in charge in rails using contractors own drilling equipment. Power supply for operating drillingequipments to be arranged by contractor.
1600
37
60080
... More
Excavation of cable trench as per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes 12 etc.,covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site.In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m
100
839
83900
... More
Digging of trench 1.2 M deep from rail flange/ road level and, 0.3Mtr to 0.6 Mtr wide 13 and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No. CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed.
100
873
87393
... More
Laying of S&T Cables of various cores/pairs/quads in trenches/GIpipes/RCC pipes/DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes 14 provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.
500
9
4685
... More
Jointing of 4 /6 quad /Signaling cable with Heat Shrinkable straight through Jointing 15 Kit. All the material required for the work are to be arrange by contractor himself at his own cost except Thermo shrinkable Joint Kit. After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost.
20
1190
23804
... More
Installation of Earth Electrodes asper Drawing No.SEM2021,19-D6, GI pipe confirming to19-D6IS:1239 of 3.0mm thickness,3.0 meter long,50.0mmdiameter, 5 mm diameter and MS Flat Plate Strip(Specification no. 226STD or latest 35 mm x 6 mm thick for earth connection to Signal post, L/Boxetc.Installation includes Excavation of earth pit,placing & fixing of Earth electrode with 16 construction of cement enclosure to SEMDrawing No. 19-D6and19-D6drawal of 6 SWG GI/Coppercable from earth electrode to goomties,relay room, cabin,station, etc. and drawal ofMS flat 35mm x 6mm for signal post/Location box shall be used as the case may be,including fixing at both ends of the wire/MS flat. This includes transportation of materials. Note:Materials such as charcoals, salt, salammoniac, 6 SWG GI wire,copper lugs with Steel bolts& nuts etc. shall be suppliedby the contractor.
10
5579
55797.7
... More
Cement concrete work for miscellaneous items in the ratio 1 : 3 :6 . Item includes excavation, ramming, curing and plastering with cement &sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand tobe supplied by the contractor).
50
6259
312950
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%