Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Western Railway - WR Tender

Works
Telecommunication Services
Ireps
Opening Date17 Jan 2025
Closing Date17 Feb 2025
Tender Amount₹ 2,69,26,968.56 
Notes
Download

Costs

Summary

Design, Supply, Installation , Programming, Testing And Commissioning Of Electronic Interlocking System Along With Outdoor Signalling Work At Charni Road Station Of Mumbai Division Western Railways

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Portable workstation for Data input & configuration with necessary software/ programs / Accessories, simulation and functional testing, diagnostics, and troubleshooting and commissioning 4 of EI system. A suitable table and chair of a reputed make shall be supplied by the contractor. Note: The specification of the portable workstation shall be as per the Technical specification given in Annexure or higher version as approved by Engineer In-Charge. All the required software should be uploaded Licensed CD should be given along with the software.

1

147350

147350.87

... More
Instruments and Tool Kits required for Trouble Shooting and repair of hardware and software for the EI system should be supplied for stations as per schedule item 1 above. This includes tools required for EI maintenance sorts of crimping, insertion, removal. General purpose tools like screwdrivers, spanners, PCB extractor, temp. Controlled soldering iron, wire cutter, nose pliers, etc. 5 Measuring instruments with carrying case/ holders/ cabinet for technicians/ J.E. for testing, Maintenance and repair at the site). Each set comprises the following: - 1. Crimping tool for all types of special cable assembly used in EI system. 2. Insertion tool for all types of special cable assembly used in EI system. 3 .Removal tool for all types of special cable assembly used in EI system. 4. Digital multimeter (Fluke 111 or better) 5. Steel cabinet/ Almira, Size: 1980mm height, 915 mm width and 485 mm depth (Godrej Make/Jalaram) of good quality to store tools, spare cards and documents.6. Clamp Earth Tester. 7. Clamp Current Meter.

1

130201

130201.33

... More
Data logger system for Railway S&T installation As per spec. IRS: S-99 2006 (Amdt3) or 6 latest. Central Monitoring Unit (Hardware Configuration as per Annexure in technical specification) with UPS minimum 06 Hrs battery backup and required Software tools. This also includes supply of one no composite computer & printer table ( work station table) for keeping Processor module and one no. operator chair model (i)1024 digital and 32 analog inputs.

1

630312

630312.5

... More
"Failure Analysis System or Central Monitoring Unit with Printer. A s per technical 7 specification IRS:S-992006 (Amdt-3) or latest. The specification of Failure Analysis System should be got approved from the Engineer in charge before supply. Note: The Specification of Failure Analysis System shall be as per technical specification or higher version as approved by Engineer In-Charge.

1

287336

287336.91

... More
Failure Analysis & Fault Diagnostic software for data logger of 1024 digital inputs/ 4096 digital inputs

1

52451

52451.4

... More
750 VA Off line UPS with battery backup 3 Hours for Failure Analysis System of reputed make as per Engineer in-charge

1

33329

33329.05

... More
Cable termination racks as per Drg. no. CSTE 5004, 5005, 5006 complete along with 10 fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated.

4

24008

96032.48

... More
"Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out- 11 put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply. " 12

2880

58

168566.4

... More
Supply of End plate 2.5mm/0.091 in thick as per site requirement. 13

720

11

7970.4

... More
Supply of End Stopper 10mm/0.0394 in width as per site requirement.

720

10

7819.2

... More
Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement.

48

113

5466.24

... More
PVC insulated Railway Signalling multi-core Indoor Cable 60core x 0.6mm Dia 15 conforming to IRS:76/89 (Amd3) or latest.

1

174705

174705.11

... More
PVC insulated Railway Signaling multi-core Indoor Cable 1 mm x 40 mm x 0.6mm Dia conforming toIRS:76/89(Amd3) or latest.

1

92180

92180.73

... More
PVC insulated Railway Signaling multi-core Indoor Cable 1mm x 24 mm x 1 mm Dia conforming to IRS:76/89(Amd3) or latest.

1

183153

183153.7

... More
Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3). 19

10

5548

55485.4

... More
Fire Extinguisher CO2 type (capacity 5 kg or 4.5 kg)

4

6814

27256.2

... More
Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm.( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest.

2

33366

66732.42

... More
Flexible cable (Power wire), multi-strand copper conductors cross section 21 (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest.

2

136063

272127.1

... More
Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89.

1

132505

132505.12

... More
Indicative type Fuse base/holder with cap, suitable to G type fuse of capacity 0.63A- 3.0A.

200

50

10198

... More
Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A-3.0 A (System, Rapid, Malnad or RBCO make or similar).

200

18

3720

... More
D type fuse block non indicating type low voltage non deteriorating fuse base suitable for fuse link of capacity 2A/6A/10A as per specification IRS:S-80/92 or latest Quantity break up of each type of fuse block will be specified by Engineer in-charge.

50

31

1596.5

... More
D type fuse link non indicating type low voltage non detonating, capacity 2A/6A/10A as per specification IRS: S-80/92 or latest. Quantity break up of each type of fuse block will be specified by Engineer in-charge.

50

34

1743

... More
Fuse auto changeover system for use in Railway Signaling System as per 27 RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 32 nos. of external Non-Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits. The system shall have 8 cards with a monitoring arrangement of 4 fuses in one card. unit number= per module

6

29743

178461.78

... More
Description : Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008.

10

10403

104030.8

... More
Program switches, snap action, base mounting type along with acrylic cover and mounting bracket, 63A, 9 poles, and 3 positions make Siemens / Thakur or Similar.

10

10714

107144.5

... More
Supply of Power Supply Distribution Box with MCB/Fuse as per specification and requirement given by Site Engineer, Make 3M, SNATEL,ABB. 31

1

22300

22300.23

... More
Rubber Mat for Power Equipment room. ( 5mm thick )

30

121

3648.9

... More
Earthing of EI equipment, relay racks and Power equipment etc. to be done along with the supply of all requisite materials. Earthing shall be in the form of Ring Earth conforming to RDSO 32 specification No. RDSO/SPN/197/2008 (with a min. of 6 maintenance free earth electrodes) & RDSO Drawing issued under Railway Board letter No. 2010/Sig./SGF/EI (Ansaldo) Dated 22.06.11, made using copper rings with earth resistance less than 1 ohm. The earthing shall be maintenance free & earth enhancement compound should be used. The ring earth shall be connected to copper flat of size 25x3 mm in the relay room and IPS room. This copper flat shall be fixed on the wall to the entire breadth of the Relay room and IPS room as an earth bus bar and all earth connections shall be taken from it. A, B, C, & D class protection shall be provided for all EI equipment. Note: - This will also cover the earthing& necessary protection of EI equipment as per details given in the scope of work of Special Condition of Contract and other requirement given in Chapter of tender document & Pre- commissioning check list of EI system.

1

133269

133269.46

... More
Training of Technician/ Jr. Engineer for installation, Commissioning, Testing, Repairs &Troubleshooting of EI system.(Hard copies of training material/ course modules to be given to each participant).{unit NO. is applicable to man-days}

10

1219

12193

... More
Q series Neutral line relay AC Immunized (QNA1K) 24V DC conforming to BRS 931A (as per latest RDSO vender list) configuration 8F-8B complete with plug board.

25

5859

146485.25

... More
Relay, Non-AC Immune, plug-in type, Style 'QN1'Neutral line, 24V DC 12F-4B Contacts, 35 front and back contacts metal to carbon with plug board,retaining clip and connectors conforming to BRS:930-A,IRS S 34 & IRS S 23. The interlocking code for this unit shall be ABCDE. ACCEPTED MAKE/BRAND: JMV 36

50

4284

214224

... More
Supply of Pad locks (universal, 7 lever, Godrej)

10

196

1967.9

... More
ARA Terminal blocks with links made of PBT Spec No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4.

2400

75

180000

... More
IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x8

15

5388

80830.05

... More
"Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. . One of the 39 following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer. "

10

1912

19122

... More
"Supply of documents (Manuals for Installation, Testing, commissioning and maintenance of the system) (One set consist of 6 set of following drawings per Station). (i) Manual for installation, Testing, Commissioning and maintenance of the system for Technicians / Jr. Engineers. (Installation & Maintenance level) (ii)Functioning and system overview (Higher management level). (iii) Completion documents as per special conditions of contract. (iv) Design & Supply of circuits and plans to suit layout given in the signalling plan for Hot Standby Architecture Electronic Interlocking (EI) system. All plans and wiring diagram shall be prepared on Auto cad Drawing and supplied with CD/PENDRIVE. This will include supply of VDU diagram, Square Sheet, Wiring Diagrams (Application Logic and Interface Circuit), Fuse Analysis ,Contact Analysis, Tag Block Analysis, Power Supply Distribution / Power equipment arrangement (with program switch) Diagram, Auto Change over diagram and all other relevant drawings given in tender document. NOTE: The contactor shall initially supply 1 set of documents (Paper Prints) for approval of Railways. He shall ensure the each sheet has a block for signature of Railway official as well as a block for signature of firm, duly signed by the authorized signatory of the firm. The name of the work as given by Railways shall be written on every sheet under the work column. All the drawing shall be supplied in a good quality folder for each station. After approval of documents by Railways, the contractor will make copies of the approved documents and return the approved document to Railways. The contractor will then make necessary correction to Application Logic software duly incorporating Railways' alterations/corrections/ comments, if any. After Complete Testing / Commissioning of the station, tracings of completion documents as mentioned above will be submitted to Railways for approval. Along with the Completion application logic, difference report (showing addition & deletion indifferent colours) as compared to earlier approved application logic should also be submitted. After approval of completion application logic by Railways, 5 sets of copies of completion tracings will be submitted to Railways." 2

1

38583

38583.18

... More
Protocol converter

1

53716

53716.22

... More
Supply of DCM150 to transmit 12 vital inputs and 12 vital outputs (or 24 non-vital) block information safely via a serial interface

2

1546261

3092522

... More
"Supply of Automatic Media changeover of modem working on redundant channels for data transmission on OFC/Quad along with Modem for UFSBI (for use of secondary media OFC/Quad). Railway shall define Secondary media before placing of order"

2

177000

354000

... More
Tag block 200 way/160 way with PVC covers as per (IRS: S-77/2006 (Rev.1) or latest & Drg.no.SA-24751 & 52.

10

2122

21221.2

... More
"PVC insulated Railway Signaling Indoor Single core wire conforming to IRS 76/89 (Amd3) or latest. Note: - Wire Colours shall be decided by engineer - in - Charge. 1 x 0.6 mm"

2

2924

5849.06

... More
"PVC insulated Railway Signaling Indoor Single core wire conforming to IRS 76/89 (Amd3) or latest. Note: - Wire Colours shall be decided by engineer - in - Charge 1 x 1 mm"

2

6403

12806.7

... More
Transformer 230/110-130 V AC single phase Supply 3KVA as per spec. IRS S-72/88 with latest amendment .(For Signal and track Supply)

4

42099

168399.76

... More
Transformer Rectifier Set as per IRS(S) 91/93 Amendment-1.For Gate 230V AC /24-30V DC /20A

4

38949

155799.4

... More
"Supply, Installation, wiring, testing and commissioning of Bump less Power supply 10 Auto changeover device complete along with accessories using Contractors own wiring & fixing materials as per following configuration. i). Power Supply-AC/DC ii). Voltage 24V-150V. iii). Current Upto -45 Amp. Note: The work shall be done as per instructions of Railway's Engineer in-charge. "

10

47054

470542.8

... More
"3 phase 3 Incoming supply changeover panel with manual bypass arrangement Caapcity 63A. Auto changeover panel suitable to changeover between three incoming 3 phase 11 supplies 230V with signalling distribution arrangement, voltage sensing relays, MCB, Fuses and contactor unit as per drawing attached item includes 10 spare fuses each type, 1 contactor relay each type and 1 MCB each type used in panel Program switches and wire to be supplied based on current requirement The cabinet of auto changeover shall be powder coated and in compact size as possible" 12

1

354000

354000

... More
MSDAC mismatch panel of 120 LEDs

1

20959

20959.29

... More
SS Location box made of Spl Grade SS 304 of size as per WR CSTE Drg No. 6285 (Single app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. It includes Angle frame Relay frame fixture , earthing Rod , Drawing Board , Lock etc. as per WR CSTE Drg No. 6285.

-

-

13

... More
SS Location box made of Spl Grade SS 304 of size as per WR CSTE Drg No. 6285 (Half 14 app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. It includes Angle frame Relay frame fixture , earthing Rod , Drawing Board , Lock etc. as per WR CSTE Drg No. 6285.

6

51998

311988.36

... More
Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 20 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied.

10

8863

88638.9

... More
Phenolic laminated Sheet, grade P3 in standard size of 1200 X 1200 x 06 mm as per spec. No IS 2036 of 1995 or latest test report of manufacture to be supplied.

5

1745

8729.15

... More
Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 revision 3 With latest Amd.

25

2046

51165.75

... More
Silicone Gel based cable Jointing kit as per RDSO/SPN/TC/101/2012Amdt. 1 suitable for 18 cable Jointing of Signalling cable of various size, having dielectric strength > 20KV/mm, Non Toxic, low viscosity, Flamability point > 200 deg C, Re-entrable, Long storage life Make RAYTECH or Similar. Cable Size 12 x 1.5 Sq. mm.

40

5138

205523.6

... More
Tools for installation Silicone Gel based cable Jointing kit asper RDSO/SPN/TC/101/2012Amdt. 1 suitable for cable Jointing of Signalling cable 20

2

5299

10599.72

... More
Tic-tac Piano type Switches , 5A (ISI mark of reputed make) 21

10

32

322.4

... More
Supply of Half round RCC with 300 mm outer dia & 250 mm inner dia 1 mtr in length 22

800

301

241096

... More
Lamp holder , two pin , Bakelite type for Apparatus Cases (ISI mark of reputed make) 23

10

48

484.1

... More
CABLE ID PRINTER

-

-

256850

... More
Supply of HDPE duct 40/33 mm as per TEC GR No. G/CDS 08/02 NOV-2004 with latest 24 amendments as available. For each Km of HDPE duct following items are to be supplied a) End Plugs-2 No b) Cable sealing plugs - 2 no. c) Plastic couplers slip fit/push fit type - 2 no d) End plugs to be provided along with drum-2 nos.

3

46831

140494.98

... More
Supply of OFC jointing pits size0.6m X 0.8X 1m. The material shall be supplied as per engineer in charge instructions. 26

3

6207

18622.29

... More
Supply of 2x24 fiber optic fiber splice straight joint enclosure (SJC) complete

3

2929

8788.38

... More
Earth Leakage Detector as per RDSO/SPN/256/2002 or latest with latest amendments. 27 The basic detector unit shall comprise of 12 channels, for use on signaling circuits of 110V AC/DC and/or 60V/24V/12V DC as ordered by purchaser. If the detector is required for less number of channels, dummy plates shall be provided. For additional requirement add on /expendable cabinet may be used. The voltage specified shall be provided with + 25% and - 10% tolerance.

1

151574

151574.89

... More
Installation wiring testing and commissioning of Fuse changeover system (FACS). This 1 includes the provision of a common Buzzer & indication at the ASM Room & ESM Duty Room and the painting of fuse details. This also includes the fabrication of a frame for the installation of FACS at the Station/ LC gate where the installation of relay racks is not feasible. UNIT =PER MODULE

6

915

5492.52

... More
Provision of AUTOMATIC FIRE DETECTION & ALARM SYSTEM as per RDSO/SPN/217/2021version 2 or latest For Signalling System (Four Line station) Contractor shall supply plan and list of material with qty, rate and amount required for commissioning of station. Prior approval of rly authority to be taken

-

-

2

... More
Installation, Wiring and testing of Integrated Power Supply System. This includes power distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing of AC/DC power distribution board made on 8mm thick SMC sheets or any standard make with connections suitable for 32 A. Wiring to be done considering site requirement, 3 depending upon the load with suitable wires, lugs & glands as per instructions of Engineer-in-charge. The work includes installation of ELD's, fixing & wiring of change over switch(program switch) for selection of DG set supply (DG1 & DG2) and wiring of change over switch (program switch) for selection of mains or DG supply. This item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room etc. Any masonry work required will be carried out by contactors own material.

2

109014

218028.92

... More
Installation of LT Power Panel/Power distribution panel/ Auto Changeover Panel, power supply equipments such as Rectifiers Transformers, Battery chargers etc. including mounting on 4 wooden planks/Hylam Sheet and complete wiring for automatic change over arrangement, mounting of Program switches on Bakelite sheet of size 300mm x 300 mm x 8 mm fitted to MS angle (size 25mm x25mm x 5mm) brackets, wiring as per requirements. Necessary wires to be supplied by Rlys, lugs & glands to be supplied by Contractor.

1

21700

21700.75

... More
Installation, wiring, programming, testing and commissioning of EI equipment supplied as per supply item in schedule 'A1' including transportation from Consignee's depot to site. The works and materials for installation, wiring, testing and commissioning, grouting, cutting of floors, walls, refilling of the same, re-plastering, required CC/ masonry works, fixing/ placing/ laying of insulated ladders/ casing-capping/ cable trays/ RCC/GI pipes / Cables, termination of cables with lugs/ connectors, painting, / lettering are to be provided/ done by the contractor for the equipments supplied vide Item of Schedule "A" of this contract. This also covers the networking of built in EI Data loggers of all the stations to monitor the system to any other places where desired by Engineer-in- charge. Note: Installation shall be comply with RDSO Technical Advisory Note No STE/E/TAN/3012 dtd. 28.08.2014 or latest. Installation, wiring, programming, testing and commissioning of Operator VDU in Hot stand-by with Redundancy. Any Equipments/cards/Modules required for Hot stand-by with Redundancy shall be supplied & Installed by the Contractor. This also include supply of one no Godrej 5 make operator chair model PCH7001 or better , one no. of composite computer & printer table (Godrej work station table or better) for keeping MT , one no Godrej make operator chair model PCH7001 or better. Termination of indoor/ PIJF cables in relay room on relays, tag blocks, CT racks as per approved wiring diagram including alterations/ modifications as required at site. Soldering to be done at all required termination. Dressing/ lacing of wiring shall be done neatly with help of dressing thread / plastic self-lock strip of suitable size. The tools/ equipments/ materials/ simulation boards required for testing shall be supplied / fabricated by contactor. This included replacement of modules/ cards/ LEDs/ equipments going defective during testing. Necessary power supply boards with required capacity plugs, sockets, surge & lightning protection boxes shall be supplied and installed by the contractor. 230V supply shall be arranged by Railways. In case supplies are required to be extended, from Power room / relay room then same shall be extended by the contractor with his own materials such as 1X16 sq. mm wires, cables, lugs, RCC/GI pipes, insulated ladders etc. After ST/LT testing, Factory Acceptance Tests (FAT) & Square Sheet testing system should be fault free while submitting to Railways, otherwise suitable necessary action can be taken by Engineer-in-charge.

1

1001913

1001913

... More
Installation of Cable Termination Racks Assembly complete including wall supports, 6 scaffolding, 8 way/ARA terminals /Screw less connectors, Tag blocks & other necessary accessories etc. The work shall be done as per approved plan, extant practice on WR & the instruction of Rly engineer at site.

4

9184

36737.76

... More
Installation, wiring, testing and commissioning of Data logger complete along with 7 accessories using Contractors own wiring & fixing materials as per following configuration. (It includes loading of NETWORKING software, networking of data logger, installation of FEP & Fault diagnosis system). The requisite communication cable/channel for networking will be arranged byRailway.1024 digital & 32 analog inputs / 4096 digital & 32 analog inputs

1

21176

21176.39

... More
Fixing & wiring of QNA1 / QNA1K relays for GPR Circuit in apparatus case as per Standard practice. Fixing and wiring material shall be supplied by the contactor.

25

366

9164.5

... More
Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost. Single Case as per Drg No SK 748 or CSTE/5074 or SS Location

-

-

9

... More
Excavation and Casting of Apparatus Case foundation with contractor's own materials 10 including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost. Single Case as per Drg No SK 748 or CSTE/5074 or SS Location.Half Case as per Drg No SK 747or CSTE/5074 or SS Location.

6

5487

32927.16

... More
Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. Installation of SINGLE apparatus cases

4

1076

4305.16

... More
Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. Installation of HALF apparatus cases

6

657

3942.9

... More
Lettering & numbering of details and description writing of particulars of terminals and equipments on Apparatus cases .Writing works inside A/C single;

4

129

517.04

... More
Lettering & numbering of details and description writing of particulars of terminals and equipments on Apparatus cases Writing works inside A/C HALF;

6

88

529.08

... More
Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).

5

6259

31295

... More
Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 16 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.

5

2061

10306.8

... More
Fixing of ARA/ Wago screwless terminals and fuse block with provision of holes on hylum sheet and fixing by galvanised nuts & bolts

5280

22

120120

... More
Fabrication and fixing of SMC sheet in location box by providing all fixtures as per 18 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783-1/2. With latest alterations & as per instructions of Rly engineer at site. Single apparatus case.

4

2445

9781.44

... More
Fabrication and fixing of SMC sheet in location box by providing all fixtures as per 19 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783-1/2. With latest alterations & as per instructions of Rly engineer at site. Half apparatus case.

6

777

4666.68

... More
Installation of Maintenance Free Earth Electrode for Maintenance Free Earth spec of RDSO/SPN/197/2008.

10

1456

14567.9

... More
Excavation of cable trench as per cable route plan,1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtrs wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from 21 bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.

240

839

201360

... More
Digging of cable trench 0.3 Mtr. Deep and 0.3 Mtr. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches.

100

512

51276

... More
Digging of trench 1.2 M deep from rail flange/ road level and, 0.3 Mtr to 0.6 Mtr wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No. CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed.

25

873

21848.25

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ 24 DWC pipes/ Trucking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be daggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.

44000

9

412280

... More
Transportation and Placing of DWC/RCC/GI pipes along with collars in trenches at places of track and road crossings, platform cuttings etc.

-

-

25

... More
Digging of cable pit (min2x2x1m) as per instruction of Site Engineer, supplying and filling of sand before and after coiling the cables, covering top of the cable pit with stones and providing brick masonry on all four sides of the cable pit and plastering thereafter.

2

12567

25135.66

... More
Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50mm and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker.

50

412

20633

... More
Termination of outdoor cables, main cables laid in location boxes, Cable termination rack etc. at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends 28 of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.

2400

23

56880

... More
Transportation of S&T material leading up to 1 Km including Loading from Starting point, unloading & Stacking at destination.

50

452

22629

... More
Supply and Placing of Polyolefin Cable channel of Polyolefin Cablesize, Width 240/340 31 mm, Height 155/230internal/PC ( INCLUDING BOTTOM AND TOP COVER ) 8.00 KG ( MIN.) LENGTH PER PC/external, length 1 m produced of polyolefin with Fire protection class k-1 in accordance with DIN- 53438 Part II for laying Signalling/Telecom cables, channel attachable to each other with male-female swallow tail connectors and having suitable detachable cover.

300

2178

653436

... More
Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD in A3/A4 size. The contractor shall initially supply 3 32 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards.

1

19772

19772

... More
Releasing of Existing Panel, Power Equipments, relays and relay racks, CT racks, Batteries etc.as per the instructions of Rly Engineer at site & their transportation to nominated depot. This work to be done by contactors with his own vehicle and labour.

1

14762

14762.73

... More
Dismantling of Concrete foundation/ Demolishing RCC/CC/Stone work /Cutting Tar/ 34 carpentering/ CC Flooring / Precast concrete slab/ Brick work including leading the debris inside Railway limit or outside Railway limit as directed by site in charge. This work to be done by contactors with his own vehicle and labour.

5

605

3027.05

... More
Installation & Commissioning charges of DCM

2

64900

129800

... More
Transferring of Signaling/Telecom cables from existing Location box to New Location box . The work include breaking/ Dismantling of Existing foundation of locations, excavating and removing / segregating coils of 2C/6C/12C/19C/24C/30C/Quad cables which may be about 10 mtrs. in length. These cables are to be disconnected and removed from the existing location one by one as per 2 the instruction and under the supervision of Railway staff present at site. The cable is then to be inserted and terminated in new location box. The item includes neatly dressing of cable, making wiring tree etc.The material required to dressing /lacing will be arrange by contactor. The work is required to be done systematically and with due precaution during the block or disconnection within the time that may be allowed. The excavation work to be done carefully without damaging the cable to avoid undue failure. (Termination charges will be given separately). Note: Proportionate payment will be made if cable of other length. One No unit = One cable of 10 m length)

5

337

1685.25

... More
Laying of half round RCC pipe after laying the cables in the trenches. (Cable laying is covered separately)

-

-

3

... More
Removal of Rail (13 mtrs.) in the way of cable route. In case of panel (39 Mtrs. Each) will be consider as three rails for payment purpose. 5

20

89

1795.4

... More
Removal of PRC Sleeper in the way of cable route.

20

93

1871.2

... More
Jointing of 4 / 6 quad /Signaling cable with Heat Shrinkable straight through Jointing 6 Kit. All the material required for the work are to be arrange by contractor himself at his own cost except Thermo shrinkable Joint Kit . After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost. 7

65

1159

75342.15

... More
Supply and preparation of station SWR diagram (Tracing)

1

5653

5653.96

... More
Fabrication and supply of Board made of White sunmica sheet over 12 mm thick 8 particle/laminated/ wooden board covered with 5 mm thick pers transparent sheet in aluminium/ steel frame and Painting of SWR/Track insulation plan etc.(Inspection Agency-Consignee) (UNITNUMBER SHOULD BE READ AS PERSQ METER) 9

1

6972

6972.89

... More
Transportation and Laying of HDPE Duct pipe

3

5997

17993.13

... More
Blowing of OFC through HDPE duct & protective work (elicited in above item) already provided. 11

3

11244

33733.35

... More
Splicing of OFC cable and making the splice joint in dust free environment

3

9393

28181.34



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.