Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Western Railway - WR Tender

Works
Software and IT Solutions
Telecommunication Services
Electrical and Electronics
Electrical Works
Ireps
Opening Date30 Dec 2024
Closing Date21 Jan 2025
Tender Amount₹ 2,60,83,735 
Notes
Download

Costs

Summary

Supply, Installation, Testing And Commissioning Of Telecom Equipments For Networking Of Scada For Sp/ssp/tss In Various Ongoing Project Of Western Railway.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of way station equipment with necessary mounting arrangement on composite 4 rack or on wall. It shall be (-) 48 Volt operated and shall have a provision to connect at least four station telephones and have a facility to give more connection. As per RDSO Specification no. RDSO/SPN/TC/ 66/ 2007 or latest amd. 1 & 2.

4

63394

253576

... More
Supply of 20 pairs CT box with wago terminal for termination cables. The Box is rugged, weatherproof, and highly reliable and uses Universal Test Disconnect Terminal Blocks of PHOENIX OR WAGO Make. Epsilon/SARASWAT ENTERPRISES or as approved by Railway.

8

2596

20768

... More
Supply of 2 x 48 Fiber 2x 48 SC Type Rack Mountable FDMS loaded with SC '0' DB & Adaptor SC SM pigtail 1.5 meters with all the accessories required for installation.

8

43997

351976

... More
Supply of CLI push button telephones suitable for connection with way side equipment and the system mentioned above. as per DOT/TEC specifications TEC /GR/CP/Tele/-002/05 Jan-2010 with latest amendment IRS TC: 38/97 Amd.1 & from DOT/TEC approved firms.

8

650

5200

... More
Supply of patch cord cable (10 m long with FC-PC or LC-FC and STSC/SC-LC connector Patch cord). As per engineer incharge.

20

606

12120

... More
Supply of 2T VF Transformers, 1120:470, Cylindrical type for Derivation and Telecommunication circuits of underground cable. As per RDSO/SPEC/IRS/TC/76-2021 or Latest. Make :EPSILON / DIGITAL/ Similar Accepted.

8

1297

10376

... More
Supply of 10/12 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

4

1478

5912

... More
Supply of 19" covered racks, Vero President /Rittel make or similar having size of approximately 2.2 mtr. (42U) height x 600mm width x 600mm depth and duly approved by the 1 engineer in charge of the work. The rack shall be complete with all fittings for housing SDH equipment, primary Muxes, DDF, MDF using krone module and other equipment like runway ladders etc. completely wired and equipped with integrated protection modules for all channels. It should be possible to lock all the equipment with only order wire telephone remaining outside the rack.

4

37712

150848

... More
Supply of 48V Managed media converter (Ethernet/E1 to Optical) as per RDSO spec No. RDSO/SPN/TC/103/2013, Rev 2.0 or latest and as per details given below for SCADA working. Its supply includes three tributary slots & one optical module supporting distance of 20 Kms with (1+1) protection on optical interface (one dual core & one single core) , 2E1 ports and four 100Mbps ETH interface through Optical interface and built in DSL modem to work on quad or copper (2W) up to five 2 kms with auto change over feature between DSL line (2W) & Optical interfaces and three tributary slots loaded with one four port E&M interface supporting 2W/4W configurable for TPC / EC provision; one tributary slot loaded with ETH module supporting RSTP feature for connecting RTU and one tributary module support four port two wire voice for connecting hotline & Auto phone ( 2 port each (FXO & FXS ). Unit to be standard telecom rack mountable and supplied with rack mounting kit / Unit to have E1 tributary module supporting two E1 as option for converting E1 to ETH for RTU purpose at SSP/SP/TSS locations. Type of Media convertor- option3, Media convertor- without POE, patch cord cable- not required, SFP- should support 20KMS distance. Inspection by RITES.

10

298544

2985440

... More
Supply of Two Port E1 module which can be accommodated in the Managed media converter to convert E1 to ETH for SCADA purpose similar (Inspection by consignee)

10

24816

248160

... More
Supply of way station equipment with necessary mounting arrangement on composite 4 rack or on wall. It shall be (-) 48 Volt operated and shall have a provision to connect at least four station telephones and have a facility to give more connection. As per RDSO Specification no. RDSO/SPN/TC/ 66/ 2007 or latest amd. 1 & 2.

4

63394

253576

... More
Supply of 20 pairs CT box with wago terminal for termination cables. The Box is rugged, weatherproof, and highly reliable and uses Universal Test Disconnect Terminal Blocks of PHOENIX OR WAGO Make. Epsilon/SARASWAT ENTERPRISES or as approved by Railway.

8

2596

20768

... More
Supply of 2 x 48 Fiber 2x 48 SC Type Rack Mountable FDMS loaded with SC '0' DB & Adaptor SC SM pigtail 1.5 meters with all the accessories required for installation.

8

43997

351976

... More
Supply of CLI push button telephones suitable for connection with way side equipment and the system mentioned above. as per DOT/TEC specifications TEC /GR/CP/Tele/-002/05 Jan-2010 with latest amendment IRS TC: 38/97 Amd.1 & from DOT/TEC approved firms.

-

-

7

... More
Supply of patch cord cable (10 m long with FC-PC or LC-FC and STSC/SC-LC connector Patch cord). As per engineer incharge.

20

606

12120

... More
Supply of 2T VF Transformers, 1120:470, Cylindrical type for Derivation and Telecommunication circuits of underground cable. As per RDSO/SPEC/IRS/TC/76-2021 or Latest.Make :EPSILON / DIGITAL/ Similar Accepted.

8

1297

10376

... More
Supply of 10/12 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

4

1478

5912

... More
Supply of 19" covered racks, Vero President /Rittel make or similar having size of approximately 2.2 mtr. (42U) height x 600mm width x 600mm depth and duly approved by the 1 engineer in charge of the work. The rack shall be complete with all fittings for housing SDH equipment, primary Muxes, DDF, MDF using krone module and other equipment like runway ladders etc. completely wired and equipped with integrated protection modules for all channels. It should be possible to lock all the equipment with only order wire telephone remaining outside the rack.

2

37712

75424

... More
Supply of 48V Managed media converter (Ethernet/E1 to Optical) as per RDSO spec No. RDSO/SPN/TC/103/2013, Rev 2.0 or latest and as per details given below for SCADA working. Its supply includes three tributary slots & one optical module supporting distance of 20 Kms with (1+1) protection on optical interface (one dual core & one single core) , 2E1 ports and four 100Mbps ETH interface through Optical interface and built in DSL modem to work on quad or copper (2W) up to five 2 kms with auto change over feature between DSL line (2W) & Optical interfaces and three tributary slots loaded with one four port E&M interface supporting 2W/4W configurable for TPC / EC provision; one tributary slot loaded with ETH module supporting RSTP feature for connecting RTU and one tributary module support four port two wire voice for connecting hotline & Auto phone ( 2 port each (FXO & FXS ). Unit to be standard telecom rack mountable and supplied with rack mounting kit / Unit to have E1 tributary module supporting two E1 as option for converting E1 to ETH for RTU purpose at SSP/SP/TSS locations. Type of Media convertor- option3, Media convertor- without POE, patch cord cable- not required, SFP- should support 20KMS distance. Inspection by RITES.

6

298544

1791264

... More
Supply of Two Port E1 module which can be accommodated in the Managed media converter to convert E1 to ETH for SCADA purpose similar (Inspection by consignee)

6

24816

148896

... More
Supply of way station equipment with necessary mounting arrangement on composite 4 rack or on wall. It shall be (-) 48 Volt operated and shall have a provision to connect at least four station telephones and have a facility to give more connection. As per RDSO Specification no. RDSO/SPN/TC/ 66/ 2007 or latest amd. 1 & 2.

2

63394

126788

... More
Supply of 20 pairs CT box with wago terminal for termination cables. The Box is rugged, weatherproof, and highly reliable and uses Universal Test Disconnect Terminal Blocks of PHOENIX OR WAGO Make. Epsilon/SARASWAT ENTERPRISES or as approved by Railway.

4

2596

10384

... More
Supply of 2 x 48 Fiber 2x 48 SC Type Rack Mountable FDMS loaded with SC '0' DB & Adaptor SC SM pigtail 1.5 meters with all the accessories required for installation.

4

43997

175988

... More
Supply of CLI push button telephones suitable for connection with way side equipment and the system mentioned above. as per DOT/TEC specifications TEC /GR/CP/Tele/-002/05 Jan-2010 with latest amendment IRS TC: 38/97 Amd.1 & from DOT/TEC approved firms.

4

650

2600

... More
Supply of patch cord cable (10 m long with FC-PC or LC-FC and STSC/SC-LC connector Patch cord). As per engineer incharge.

10

606

6060

... More
Supply of 2T VF Transformers, 1120:470, Cylindrical type for Derivation and Telecommunication circuits of underground cable. As per RDSO/SPEC/IRS/TC/76-2021 or Latest.Make :EPSILON / DIGITAL/ Similar Accepted.

-

-

9

... More
Supply of 10/12 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

2

1478

2956

... More
Supply of 19" covered racks, Vero President /Rittel make or similar having size of approximately 2.2 mtr. (42U) height x 600mm width x 600mm depth and duly approved by the 1 engineer in charge of the work. The rack shall be complete with all fittings for housing SDH equipment, primary Muxes, DDF, MDF using krone module and other equipment like runway ladders etc. completely wired and equipped with integrated protection modules for all channels. It should be possible to lock all the equipment with only order wire telephone remaining outside the rack.

2

37712

75424

... More
Supply of 48V Managed media converter (Ethernet/E1 to Optical) as per RDSO spec No. RDSO/SPN/TC/103/2013, Rev 2.0 or latest and as per details given below for SCADA working. Its supply includes three tributary slots & one optical module supporting distance of 20 Kms with (1+1) protection on optical interface (one dual core & one single core) , 2E1 ports and four 100Mbps ETH interface through Optical interface and built in DSL modem to work on quad or copper (2W) up to five 2 kms with auto change over feature between DSL line (2W) & Optical interfaces and three tributary slots loaded with one four port E&M interface supporting 2W/4W configurable for TPC / EC provision; one tributary slot loaded with ETH module supporting RSTP feature for connecting RTU and one tributary module support four port two wire voice for connecting hotline & Auto phone ( 2 port each (FXO & FXS ). Unit to be standard telecom rack mountable and supplied with rack mounting kit / Unit to have E1 tributary module supporting two E1 as option for converting E1 to ETH for RTU purpose at SSP/SP/TSS locations. Type of Media convertor- option3, Media convertor- without POE, patch cord cable- not required, SFP- should support 20KMS distance. Inspection by RITES.

6

298544

1791264

... More
Supply of Two Port E1 module which can be accommodated in the Managed media converter to convert E1 to ETH for SCADA purpose similar (Inspection by consignee)

6

24816

148896

... More
Supply of way station equipment with necessary mounting arrangement on composite 4 rack or on wall. It shall be (-) 48 Volt operated and shall have a provision to connect at least four station telephones and have a facility to give more connection. As per RDSO Specification no. RDSO/SPN/TC/ 66/ 2007 or latest amd. 1 & 2.

2

63394

126788

... More
Supply of 20 pairs CT box with wago terminal for termination cables. The Box is rugged, weatherproof, and highly reliable and uses Universal Test Disconnect Terminal Blocks of PHOENIX OR WAGO Make. Epsilon/SARASWAT ENTERPRISES or as approved by Railway.

4

2596

10384

... More
Supply of 2 x 48 Fiber 2x 48 SC Type Rack Mountable FDMS loaded with SC '0' DB & Adaptor SC SM pigtail 1.5 meters with all the accessories required for installation.

4

43997

175988

... More
Supply of CLI push button telephones suitable for connection with way side equipment and the system mentioned above. as per DOT/TEC specifications TEC /GR/CP/Tele/-002/05 Jan-2010 with latest amendment IRS TC: 38/97 Amd.1 & from DOT/TEC approved firms.

4

650

2600

... More
Supply of patch cord cable (10 m long with FC-PC or LC-FC and STSC/SC-LC connector Patch cord). As per engineer incharge.

10

606

6060

... More
Supply of 2T VF Transformers, 1120:470, Cylindrical type for Derivation and Telecommunication circuits of underground cable. As per RDSO/SPEC/IRS/TC/76-2021 or Latest.Make :EPSILON / DIGITAL/ Similar Accepted.

4

1297

5188

... More
Supply of 10/12 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

2

1478

2956

... More
Supply of 19" covered racks, Vero President /Rittel make or similar having size of approximately 2.2 mtr. (42U) height x 600mm width x 600mm depth and duly approved by the 1 engineer in charge of the work. The rack shall be complete with all fittings for housing SDH equipment, primary Muxes, DDF, MDF using krone module and other equipment like runway ladders etc. completely wired and equipped with integrated protection modules for all channels. It should be possible to lock all the equipment with only order wire telephone remaining outside the rack.

8

37712

301696

... More
Supply of 48V Managed media converter (Ethernet/E1 to Optical) as per RDSO spec No. RDSO/SPN/TC/103/2013, Rev 2.0 or latest and as per details given below for SCADA working. Its supply includes three tributary slots & one optical module supporting distance of 20 Kms with (1+1) protection on optical interface (one dual core & one single core) , 2E1 ports and four 100Mbps ETH interface through Optical interface and built in DSL modem to work on quad or copper (2W) up to five 2 kms with auto change over feature between DSL line (2W) & Optical interfaces and three tributary slots loaded with one four port E&M interface supporting 2W/4W configurable for TPC / EC provision; one tributary slot loaded with ETH module supporting RSTP feature for connecting RTU and one tributary module support four port two wire voice for connecting hotline & Auto phone ( 2 port each (FXO & FXS ). Unit to be standard telecom rack mountable and supplied with rack mounting kit / Unit to have E1 tributary module supporting two E1 as option for converting E1 to ETH for RTU purpose at SSP/SP/TSS locations. Type of Media convertor- option3, Media convertor- without POE, patch cord cable- not required, SFP- should support 20KMS distance. Inspection by RITES.

18

298544

5373792

... More
Supply of Two Port E1 module which can be accommodated in the Managed media converter to convert E1 to ETH for SCADA purpose similar (Inspection by consignee)

18

24816

446688

... More
Supply of way station equipment with necessary mounting arrangement on composite 4 rack or on wall. It shall be (-) 48 Volt operated and shall have a provision to connect at least four station telephones and have a facility to give more connection. As per RDSO Specification no. RDSO/SPN/TC/ 66/ 2007 or latest amd. 1 & 2.

8

63394

507152

... More
Supply of 20 pairs CT box with wago terminal for termination cables. The Box is rugged, weatherproof, and highly reliable and uses Universal Test Disconnect Terminal Blocks of PHOENIX OR WAGO Make. Epsilon/SARASWAT ENTERPRISES or as approved by Railway.

14

2596

36344

... More
Supply of 2 x 48 Fiber 2x 48 SC Type Rack Mountable FDMS loaded with SC '0' DB & Adaptor SC SM pigtail 1.5 meters with all the accessories required for installation.

14

43997

615958

... More
Supply of CLI push button telephones suitable for connection with way side equipment and the system mentioned above. as per DOT/TEC specifications TEC /GR/CP/Tele/-002/05 Jan-2010 with latest amendment IRS TC: 38/97 Amd.1 & from DOT/TEC approved firms.

14

650

9100

... More
Supply of patch cord cable (10 m long with FC-PC or LC-FC and STSC/SC-LC connector Patch cord). As per engineer incharge.

40

606

24240

... More
Supply of 2T VF Transformers, 1120:470, Cylindrical type for Derivation and Telecommunication circuits of underground cable. As per RDSO/SPEC/IRS/TC/76-2021 or Latest.Make :EPSILON / DIGITAL/ Similar Accepted.

14

1297

18158

... More
Supply of 10/12 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

7

1478

10346

... More
Supply of 19" covered racks, Vero President /Rittel make or similar having size of approximately 2.2 mtr. (42U) height x 600mm width x 600mm depth and duly approved by the 1 engineer equipment, primary Muxes, DDF, MDF using krone module and other equipment like runway laddersin charge of the work. The rack shall be complete with all fittings for housing SDH etc. completely wired and equipped with integrated protection modules for all channels. It should be possible to lock all the equipment with only order wire telephone remaining outside the rack.

2

37712

75424

... More
Supply of 48V Managed media converter (Ethernet/E1 to Optical) as per RDSO spec No. RDSO/SPN/TC/103/2013, Rev 2.0 or latest and as per details given below for SCADA working. Its supply includes three tributary slots & one optical module supporting distance of 20 Kms with (1+1) protection on optical interface (one dual core & one single core) , 2E1 ports and four 100Mbps ETH interface through Optical interface and built in DSL modem to work on quad or copper (2W) up to five 2 kms with auto change over feature between DSL line (2W) & Optical interfaces and three tributary slots loaded with one four port E&M interface supporting 2W/4W configurable for TPC / EC provision; one tributary slot loaded with ETH module supporting RSTP feature for connecting RTU and one tributary module support four port two wire voice for connecting hotline & Auto phone ( 2 port each (FXO & FXS ). Unit to be standard telecom rack mountable and supplied with rack mounting kit / Unit to have E1 tributary module supporting two E1 as option for converting E1 to ETH for RTU purpose at SSP/SP/TSS locations. Type of Media convertor- option3, Media convertor- without POE, patch cord cable- not required, SFP- should support 20KMS distance. Inspection by RITES.

6

298544

1791264

... More
Supply of Two Port E1 module which can be accommodated in the Managed media converter to convert E1 to ETH for SCADA purpose similar (Inspection by consignee)

6

24816

148896

... More
Supply of way station equipment with necessary mounting arrangement on composite 4 rack or on wall. It shall be (-) 48 Volt operated and shall have a provision to connect at least four station telephones and have a facility to give more connection. As per RDSO Specification no. RDSO/SPN/TC/ 66/ 2007 or latest amd. 1 & 2.

2

63394

126788

... More
Supply of 20 pairs CT box with wago terminal for termination cables. The Box is rugged, weatherproof, and highly reliable and uses Universal Test Disconnect Terminal Blocks of PHOENIX OR WAGO Make. Epsilon/SARASWAT ENTERPRISES or as approved by Railway.

4

2596

10384

... More
Supply of 2 x 48 Fiber 2x 48 SC Type Rack Mountable FDMS loaded with SC '0' DB & Adaptor SC SM pigtail 1.5 meters with all the accessories required for installation.

4

43997

175988

... More
Supply of CLI push button telephones suitable for connection with way side equipment and the system mentioned above. as per DOT/TEC specifications TEC /GR/CP/Tele/-002/05 Jan-2010 with latest amendment IRS TC: 38/97 Amd.1 & from DOT/TEC approved firms.

4

650

2600

... More
Supply of patch cord cable (10 m long with FC-PC or LC-FC and STSC/SC-LC connector Patch cord). As per engineer incharge.

10

606

6060

... More
Supply of 2T VF Transformers, 1120:470, Cylindrical type for Derivation and Telecommunication circuits of underground cable. As per RDSO/SPEC/IRS/TC/76-2021 or Latest.Make :EPSILON / DIGITAL/ Similar Accepted.

4

1297

5188

... More
Supply of 10/12 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

4

1478

5912

... More
Installation, wiring testing and commissioning of way side equipment and telephone on the rack as per consignee in charge.

4

2732

10928

... More
Fixing of 10/12/20 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

12

381

4572

... More
Supply, Installation, testing, and commissioning of surge protection cum safety device (Class B + Class C) suitable for single phase for Telecom Equipment as per RDSO specification No. RDSO/SPN/TC/98/2011, Rev. 0 with Amendment No.1 or latest.

8

18685

149480

... More
Installation, Testing & commissioning of OFC Equipment for SCADA per location between OFC room & SP/SSP/TSS and in Test room.

10

18048

180480

... More
Supply and Fixing of 19" size, 12U size height Wall Mounting type front glass door with lock and 2 keys and Rack duly fixed with fans, Multi Valrack. It should be suitably supported with angles at the bottom. point AC power strip, cable organizer with suitable wall fixing screws of MRS, HCL or Similar.

4

13081

52324

... More
Installation of fiber distribution management system (Supply covered Above) with all 6 installation materials, restoration wall etc. to original condition , splicing and termination of 2 x 48 fiber cable (With all contractor's materials), routing/ dressing fibers as per directions of Engineer in- charge.

8

3914

31312

... More
Excavation of trench 300mm wide at the bottom and 1.2 mtr deep, in all type of soils including clearing of trees, bushes, etc. and refilling of cable trench by excavated soil and ramming after laying of HDPE DUCT (laying of HDPE/DWC & 6 Quad. cables, PDF cables etc., will be paid under 7 different items of the schedule). Where desired dimensions of trenches could not be achieved proportionate payment will be made as decided by Engineer-in-charge of the Railway at site. The trenching outside the station limits I.e.) between the home signal of station 'A' to home signal of station 'B' may be done manually or by machine, as per the directions of site in charge. In no case the payment will be made for the trench of higher dimensions, than the dimensions as mentioned above

3600

280

1008000

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the 8 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the end of duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

10

6391

63910

... More
Blowing of OFC through HDPE duct & protective work (elicited in above item) already 9 provided. Where it is not feasible to blow OFC due to curves, road/track crossings, bridges or for any other reason, OFC shall be drawn /laid manually as per standard procedure. All the equipments and machinery required shall be arranged by the contractor at his own cost. OFC and HDPE pipe shall be supplied by the railway.

10

12032

120320

... More
Supply of Straight Joint Enclosures (SJC) complete with all accessories as per GR/ OJC 10 /02/02 Sept 2003 for 48 fiber, Raychem make model FOSC 400 B4 48F or RSICS make model 1500-L 183-XX or Birla VXL make model VT-200 or 3 M make model 2179 CS or TYCO make or better as per instruction and approval of Engineer In charge.

5

4088

20440

... More
Splicing of laid under above items OFC cable and making the splice joint in dust free environment with contractor's own equipments and labour. Straight joint enclosure (SJC) is covered under schedule 'A' remaining all required materials, tools , plants shall be arranged by the contractor. 11 splicing shall be started from one end and each splicing shall be monitored after splicing and after closing the enclosure for all the fibers from one central location by contractor's engineer with his own OTDR and optic Talk set with railway engineer , trace for the fibers shall be taken and signed jointly, if any fibred splice shows high loss/lossy event, the same shall be redone before completion of splicing work. The splice loss shall be as per the policy/technical circulars issued by the railways from time to time.

5

7482

37410

... More
End to end testing of all fiber of the optical fibred cable laid under above items 12 between station/cable huts. All required equipments, tools and plants shall be arranged by the contractor. Five nos. of print out of traces in folders of OFC parameters/ results, The per kilometer link loss shall be as per the policy/technical circulars issued by the railways from time to time.

1

14387

14387

... More
Supply of Plasto crate pre-fabricated (RCC) OFC jointing pits size 0.6mx 0.8mx1m.The material shall be supplied as per engineer in charge instructions.

5

5299

26495

... More
Installation, wiring testing and commissioning of way side equipment and telephone on the rack as per consignee in charge.

4

2732

10928

... More
Fixing of 10/12/20 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

12

381

4572

... More
Supply, Installation, testing, and commissioning of surge protection cum safety device (Class B + Class C) suitable for single phase for Telecom Equipment as per RDSO specification No. RDSO/SPN/TC/98/2011, Rev. 0 with Amendment No.1 or latest.

-

-

3

... More
Installation, Testing & commissioning of OFC Equipment for SCADA per location between OFC room & SP/SSP/TSS and in Test room.

10

18048

180480

... More
Supply and Fixing of 19" size, 12U size height Wall Mounting type front glass door with 5 lock and 2 keys and Rack duly fixed with fans, Multi Valrack. It should be suitably supported with angles at the bottom. point AC power strip, cable organizer with suitable wall fixing screws of MRS, HCL or Similar.

6

13081

78486

... More
Installation of fiber distribution management system (Supply covered Above) with all 6 installation materials, restoration wall etc. to original condition , splicing and termination of 2 x 48 fiber cable (With all contractor's materials), routing/ dressing fibers as per directions of Engineer in- charge.

8

3914

31312

... More
Installation, wiring testing and commissioning of way side equipment and telephone on the rack as per consignee in charge.

2

2732

5464

... More
Fixing of 10/12/20 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

6

381

2286

... More
Supply, Installation, testing, and commissioning of surge protection cum safety device (Class B + Class C) suitable for single phase for Telecom Equipment as per RDSO specification No. RDSO/SPN/TC/98/2011, Rev. 0 with Amendment No.1 or latest.

4

18685

74740

... More
Installation, Testing & commissioning of OFC Equipment for SCADA per location between OFC room & SP/SSP/TSS and in Test room.

6

18048

108288

... More
Supply and Fixing of 19" size, 12U size height Wall Mounting type front glass door with 5 lock and 2 keys and Rack duly fixed with fans, Multi Valrack. It should be suitably supported with angles at the bottom. point AC power strip, cable organizer with suitable wall fixing screws of MRS, HCL or Similar.

2

13081

26162

... More
Installation of fiber distribution management system (Supply covered Above) with all 6 installation materials, restoration wall etc. to original condition , splicing and termination of 2 x 48 fiber cable (With all contractor's materials), routing/ dressing fibers as per directions of Engineer in- charge.

4

3914

15656

... More
Installation, wiring testing and commissioning of way side equipment and telephone on the rack as per consignee in charge.

2

2732

5464

... More
Fixing of 10/12/20 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

6

381

2286

... More
Supply, Installation, testing, and commissioning of surge protection cum safety device (Class B + Class C) suitable for single phase for Telecom Equipment as per RDSO specification No. RDSO/SPN/TC/98/2011, Rev. 0 with Amendment No.1 or latest.

4

18685

74740

... More
Installation, Testing & commissioning of OFC Equipment for SCADA per location between OFC room & SP/SSP/TSS and in Test room.

6

18048

108288

... More
Supply and Fixing of 19" size, 12U size height Wall Mounting type front glass door with 5 lock and 2 keys and Rack duly fixed with fans, Multi Valrack. It should be suitably supported with angles at the bottom. point AC power strip, cable organizer with suitable wall fixing screws of MRS, HCL or Similar.

2

13081

26162

... More
Installation of fiber distribution management system (Supply covered Above) with all 6 installation materials, restoration wall etc. to original condition , splicing and termination of 2 x 48 fiber cable (With all contractor's materials), routing/ dressing fibers as per directions of Engineer in- charge.

4

3914

15656

... More
Installation, wiring testing and commissioning of way side equipment and telephone on the rack as per consignee in charge.

8

2732

21856

... More
Fixing of 10/12/20 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

21

381

8001

... More
Supply, Installation, testing, and commissioning of surge protection cum safety device (Class B + Class C) suitable for single phase for Telecom Equipment as per RDSO specification No. RDSO/SPN/TC/98/2011, Rev. 0 with Amendment No.1 or latest.

14

18685

261590

... More
Installation, Testing & commissioning of OFC Equipment for SCADA per location between OFC room & SP/SSP/TSS and in Test room.

18

18048

324864

... More
Supply and Fixing of 19" size, 12U size height Wall Mounting type front glass door with 5 lock and 2 keys and Rack duly fixed with fans, Multi Valrack. It should be suitably supported with angles at the bottom. point AC power strip, cable organizer with suitable wall fixing screws of MRS, HCL or Similar.

8

13081

104648

... More
Installation of fiber distribution management system (Supply covered Above) with all 6 installation materials, restoration wall etc. to original condition , splicing and termination of 2 x 48 fiber cable (With all contractor's materials), routing/ dressing fibers as per directions of Engineer in- charge.

14

3914

54796

... More
Installation, wiring testing and commissioning of way side equipment and telephone on the rack as per consignee in charge.

2

2732

5464

... More
Fixing of 10/12/20 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

8

381

3048

... More
Supply, Installation, testing, and commissioning of surge protection cum safety device (Class B + Class C) suitable for single phase for Telecom Equipment as per RDSO specification No. RDSO/SPN/TC/98/2011, Rev. 0 with Amendment No.1 or latest.

4

18685

74740

... More
Installation, Testing & commissioning of OFC Equipment for SCADA per location between OFC room & SP/SSP/TSS and in Test room.

6

18048

108288

... More
Supply and Fixing of 19" size, 12U size height Wall Mounting type front glass door with 5 lock and 2 keys and Rack duly fixed with fans, Multi Valrack. It should be suitably supported with angles at the bottom. point AC power strip, cable organizer with suitable wall fixing screws of MRS, HCL or Similar.

2

13081

26162

... More
Installation of fiber distribution management system (Supply covered Above) with all installation materials, restoration wall etc. to original condition , splicing and termination of 2 x 48 fiber cable (With all contractor's materials), routing/ dressing fibers as per directions of Engineer in- charge.

-

-

6



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.