National Environmental Engineering Research Institute Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
National Environmental Engineering Research Institute - NEERI Tender
Eprocure
Opening Date27 Aug 2021
Closing Date3 Sep 2021
Tender Amount₹ 31,42,133
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_CSIR_84202_2Bid Award Id
ViewTender No
50(13E)/19-20/WTender Authority
National Environmental Engineering Research Institute ViewPurchaser Address
-Website
http://csir.res.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
200
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
3 X 2.5 sq. mm
715
-
-
3 X 4 sq. mm
25
-
-
3 X 6 sq. mm
25
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
-
-
-
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
26
-
-
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
26
-
-
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
26
-
-
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
26
-
-
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required
-
-
-
2 Pair
40
-
-
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit , or cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
40
-
-
25 mm
370
-
-
32 mm
26
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
390
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
5/6 A switch
110
-
-
15/16 A switch
20
-
-
3 pin 5/6 A socket outlet
110
-
-
6 pin 15/16 A socket outlet
50
-
-
Telephone socket outlet
3
-
-
Bell push
3
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
30
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
-
-
-
1 or 2 Module (75mmX75mm)
24
-
-
3 Module (100mmX75mm)
5
-
-
4 Module (125mmX75mm)
7
-
-
6 Module (200mmX75mm)
30
-
-
8 Module (125mmX125mm)
8
-
-
12 Module (200mmX150mm)
5
-
-
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
98
-
-
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
2
-
-
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
5
-
-
supplying energy saving , 5 star rated, 43 watts , white coloured ceiling fan with double ball bearing condenser A.C. 230 V . Of 1200mm sweep complete with conopy and rubber bushing having air delivery 215 cmm with speed 330 rpm all accessories etc. including fan clamp of M.S. bar with hook of 16mm thick with glossy paint for superior finish as required. (with guarantee of two years )
5
-
-
Supply, installation testing and commisioning of air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable protection unit, totally enclosed, flame proof motor suitable metre of 3 core lead wire and with moisture proof treatment to winding and with E‘ class insulation
15
-
-
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
124
-
-
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
-
-
-
Upto 450 mm sweep
3
-
-
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
3
-
-
supplying energy saving heavy duty, 145 watt grey coloured exhaust fan, with dynamically balanced impellers for smooth and vibration free operations , AC 230 V , 450 mm sweep complete having 3000 m/hr air delievery with 900 rpm . ( with guarantee of two years )
3
-
-
Supplying oudoor louvers/shutters of size 450mm made up of GI sheet of size 0.6 mm thick, and required frame, necessary arrangement for lifting louvers.
3
-
-
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel conduit as required.
-
-
-
1 run of cable
375
-
-
Supplying and fixing ISI mark modular type computer jack RJ 45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
15
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
8 way , Double door
3
-
-
12 way , Double door
1
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
4 way (4 + 12), Double door
6
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
96
-
-
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
40 A
4
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required
-
-
-
40 A
6
-
-
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
3
-
-
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
1
-
-
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
-
-
-
150 mm width X 50 mm depth X 1.6 mm thickness
35
-
-
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5
-
-
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
80
-
-
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
40
-
-
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re - filling as required.
50
-
-
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
3
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation sand cushioning , protective covering and and refilling the trench etc as required.
-
-
-
Above 35 sq. mm and upto 95 sq. mm
300
-
-
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground in the same trench in one tier horizontal formation including excavation , sand cushioning , protective covering and refilling the trench etc. as required.
-
-
-
Above 35 sq. mm and upto 95 sq. mm
300
-
-
supplying aluminium armoured stranded conductor of cable 3.5 core 50 sqmm of XLPE insulated (cross linked polythelene ) PVC sheathed , armoured with galvanised round / strip steel , 1100 V . Grade conforming to I.S. 1554 (part-1) & IS : 7098 (part-1).
405
-
-
supplying aluminium armoured stranded conductor of cable 3.5 core 70 sqmm of XLPE insulated (cross linked polythelene ) PVC sheathed , armoured with galvanised round / strip steel , 1100 V . Grade conforming to I.S. 1554 (part-1) & IS : 7098 (part-1).
305
-
-
supplying aluminium armoured stranded conductor of cable 2 core 6 sqmm of XLPE insulated (cross linked polythelene ) PVC sheathed , armoured with galvanised round / strip steel , 1100 V . Grade conforming to I.S. 1554 (part-1) & IS : 7098 (part-1).
30
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
2 X 6 sq. mm (19mm)
6
-
-
3½ X 50 sq. mm (35mm)
4
-
-
3½ X 70 sq. mm (38mm)
4
-
-
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
3½ X 70 sq. mm
1
-
-
Supplying and laying of following size DWC HDPE pipe ISI along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
-
-
-
90 mm dia (OD-90 mm & ID-76 mm nominal)
600
-
-
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)
-
-
-
Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
3
-
-
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
17
-
-
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
3
-
-
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
2
-
-
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required
1
-
-
Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required.
1
-
-
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.4 Zone
1
-
-
Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set.
1
-
-
CABLING & WIRING
-
-
-
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
60
-
-
Supplying of square / rectangular shaped CRCA /diecast aluminium powder coated housing LED panel (slim edge-lit) light, having lumens of 3000 lm, cool white suitable for 32W with provision for plane front frame with translucent cover fixed to the housing complete.
76
-
-
Supplying of LED square / circular 12W down lighter with more than 100 lumens, white color, having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
20
-
-
Supplying suspension type decorative pendent fitting single light having more than 60 lumens, white color with anodized aluminium / powder coated MS rod up to 1 m length and canopy on top provided with decorative glass shed duly wired with two core flat wire suitable lamp holder complete.
2
-
-
P/F Street light luminaires 20 w LED: Prioviding and fixing Street light fitting in the exeisting pole/ bracket, fitting shall be comprises of die cast aluminium housing, pipe mounting type with a normal system lumen output of 100 Lumens/watt. The luminaire shall have a rated system lifetime of 15000 burning hours. The luminaire shall have high efficiency diffuser, heat resistance toughened glass. The total power consumption should not exceed 20 Watts, operates on voltage 150-240 V, 50 Hz. etc. complete with all accessories, IP 65 protection for optical compartment with high power LEDs and driver with efficiency 0.85, optics should be such that it gives uniform distribution and having surge protection device. Make: Crompton / Philips /Insta/Havells/Osram or equivalent Make in India.
3
-
-
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
3
-
-
Design supply installation testing & commissioning floor mounted MV cubical (MDB)panel made from 14 SWG CRCA sheet powder coated ( not less than 2.00 mm thick ) (smoke grey paint) powder quoted dust & vermin proof capable to take all following accessories as per cables. all the switches & main busbar should be fixed in seperate compartment & having hinged doors the panel should comprises of all accessories as required (as per drawing attached ) The design should include all provisions for safety of operating & maintenance personnel . The general construction shall confirm to IS : 8623/77 & IP 42. LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measures & displays trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 100/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs. As per detailed specification attached Material
-
-
-
MCCB, 40A , 4P , TM Ics=Icu=25A with thermal magnetic RELEASE (O/L, S/C/, E/F) - 1 nos VOLTMETER - DIGITAL DISPLAY AMMETER - DIGITAL DISPLAY IND LAMPS R,Y,B RELEASE(O/L, S/C )- 10 Nos ASS VSS MCCB , 40 TO 63A, 3P, TM, Ics=Icu=25KA WITH THERMAL MAGNETIC ASS CT 5/5A DANGER NOTICE PLATE
1
-
-
Design supply installation testing & commissioning floor mounted MV cubical panel for HVAC made from 14 SWG CRCA sheet powder coated ( not less than 2.00 mm thick ) (smoke grey paint) powder quoted dust & vermin proof capable to take all following accessories as per cables. all the switches & main busbar should be fixed in seperate compartment & having hinged doors the panel should comprises of all accessories as required (as per drawing attached ) The design should include all provisions for safety of operating & maintenance personnel . The general construction shall confirm to IS : 8623/77 & IP 42. LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measures & displays trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 100/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
-
-
-
As per detailed specification attached Material MCCB, 80A , 4P , TM Ics=Icu=25A with thermal magnetic RELEASE (O/L, S/C/, E/F) - 1 nos VOLTMETER - DIGITAL DISPLAY AMMETER - DIGITAL DISPLAY IND LAMPS R,Y,B ASS VSS MCCB , 20 TO 32A, 3P, TM, Ics=Icu=25KA WITH THERMAL MAGNETIC RELEASE(O/L, S/C )- 6 Nos ASS CT 5/5A DANGER NOTICE PLATE
1
-
-
Design supply installation testing & commissioning floor mounted MV cubical panel for existing panel made from 14 SWG CRCA sheet powder coated ( not less than 2.00 mm thick ) (smoke grey paint) powder quoted dust & vermin proof capable to take all following accessories as per cables. all the switches & main busbar should be fixed in seperate compartment & having hinged doors the panel should comprises of all accessories as required (as per drawing attached ) The design should include all provisions for safety of operating & maintenance personnel . The general construction shall confirm to IS : 8623/77 & IP 42. LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measures & displays trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 100/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
-
-
-
As per detailed specification attached Material VOLTMETER - DIGITAL DISPLAY AMMETER - DIGITAL DISPLAY IND LAMPS R,Y,B ASS VSS MCCB , 40 TO 63A, 3P, TM, Ics=Icu=25KA WITH THERMAL MAGNETIC RELEASE(O/L, S/C )- 4 Nos ASS CT 5/5A ASS CT 5/5A DANGER NOTICE PLATE
1
-
-
Design supply installation testing & commissioning floor mounted MV cubical panel for existing panel made from 14 SWG CRCA sheet powder coated ( not less than 2.00 mm thick ) (smoke grey paint) powder quoted dust & vermin proof capable to take all following accessories as per cables. all the switches & main busbar should be fixed in seperate compartment & having hinged doors the panel should comprises of all accessories as required (as per drawing attached ) The design should include all provisions for safety of operating & maintenance personnel . The general construction shall confirm to IS : 8623/77 & IP 42. LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measures & displays trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 100/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
-
-
-
As per detailed specification attached Material VOLTMETER - DIGITAL DISPLAY AMMETER - DIGITAL DISPLAY IND LAMPS R,Y,B ASS VSS MCCB , 40 TO 63A, 3P, TM, Ics=Icu=25KA WITH THERMAL MAGNETIC RELEASE(O/L, S/C )- 4 Nos ASS CT 5/5A DANGER NOTICE PLATE
1
-
-
Air Conditioning Work
-
-
-
HI-WALL SPLIT AIR CONDITIONER: Supply, Installation, Testing and Commissioning of Hi-Wall Split Air Conditioner, Inverter Type, Latest BEE Star Rating : 5 Star , Copper Condenser and Evaporator Coil, Eco-Friendly refrigerant, Operating on 1Φ, 50Hz, 230 Volts power supply, With inbuilt voltage stabilizer with operational range 180 to 260 Volts, Suitable for Indoor-Outdoor piping length not less than 20.0 Meters, Certified Operating Conditions 20 to 48 ⁰CDB and along with cordless remote control as per following cooling Capacities:
-
-
-
Cooling Capacity Range : 6500 to 12000 BTU/Hr
7
-
-
Cooling Capacity Range : 9500 to 22500 BTU/Hr
5
-
-
CASSETTE AIR CONDITIONER: Supply, Installation, Testing and Commissioning of Cassette Air Conditioner, Inverter Type, Latest BEE Star Rating : 5 Star , Copper Condenser and Evaporator Coil, Eco-Friendly refrigerant, Operating on Single Phase, 50Hz, 230 Volts or 3-Phase power supply, Suitable for Indoor-Outdoor piping length not less than 20.0 Meters, Certified Operating Conditions 20 to 48 ⁰CDB and along with cordless remote control as per following cooling Capacities:
-
-
-
Cooling Capacity Range : 18000 to 36000 BTU/Hr
3
-
-
COPPER REFRIGERANT PIPING: Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/withClass-O closed celle lastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required NOTE: 1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by : (i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe.
-
-
-
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
75
-
-
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
115
-
-
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
75
-
-
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
115
-
-
19.0 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
1
-
-
DRAIN PIPE (RIGID uPVC): Supply and complete fixing of rigid uPVC pipe of following sizes for drain water piping connections of VRF cassette type indoor units including required fittings and Supports duly insulated with 6 mm thick closed cell crosslinked polyethylene (XLPE) tubular insulation Make: ISI mark or any reputed make with prior approval of engineer.
-
-
-
Nominal Dia. Size: 32.0 mm
75
-
-
Nominal Dia. Size: 25.0 mm
75
-
-
CABLE TRAYS: Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
-
-
-
300 mm width X 62.5 mm depth X 2.0 mm thickness
25
-
-
REFRIGERANT CHARGING FOR TOP UP IN HI WALL SPLIT/CASSETTE TYPE AIR CONDITIONER: Supply, Charging and Testing of additional R-410a/R-32 gas charging in split/Cassette Air conditioner as per standard procedure recommended by Air Conditioner manufacturer and complete as required.
15
-
-
POWER CABLE FOR AIR CONDITIONER: Supply, Laying and Testing of 4 core x 4.0 Sq. mm PVC round sheathed, copper conductor Industrial cable for voltage grade upto 1100 Volts as per IS694:1990 in Dia.20.0 mm uPVC (Heavy size) conduit pipe complete as required for air conditioner as per installation guidelines given by air conditioner manufacturer.
-
-
-
Size: 4 core x 4.0 Sq. mm
75
-
-
Size: 4 core x 2.5 Sq. mm
150
-
-
MS FABRICATED STAND: Supply of MS fabricated stand duly painted with two coat of red oxide paint followed by two coat of Black enamel paint and should be suitable for the installation of O. D. units as per approved design and drawing.
200
-
-
DISMANTLING AND SHIFTING OF HI WALL SPLIT AIR CONDITIONER (Cooling Capacity: 2.0 TR): Dismantling and shifting of Hi wall Split air conditioner of following capacity as per standard pracitice recommanded by the AC manufacturer includes required pump down operation for the recovery of refrigerant, dismantling of Indoor-Outdoor unit, complete copper piping and electrical wiring, Base plate of ID Unit and mounting stand of OD unit, Shifting of dismantled material as per instructions of Engineer, at any location of institute premises.
3
-
-
WALL MOUNTING STAND/BRACKET: Supply and Fixing of Wall Mounting Stand made up of Heavy Duty GI sheet (Thickness: 2.0 MM), Powder Coated, along with required fitting material such as Screws, Anchors, Fasteners etc complete as required.
12
-
-