Military Engineer Services Tender
... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Eprocure
Opening Date12 Feb 2025
Closing Date3 Mar 2025
Tender Amount₹ 43,30,000
Costs
EMD
₹ 86,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_697542_1Tender No
8429/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M & L for Cleaning as directed & specified all rust/ scales/corrosion from reinforcement bars using rust remover Reebaklens RR- Rust remover, cleaning and etching agent supplied in 1/2, 1 and 5 Litre containers, having Specific Gravity 1.16 - 1.22 @ 25°C. Reebaklens RR cleaning agent is a combination of acid based material, corrosion inhibitors and dispersing agents and is supplied as a clear green solution. Application of Reebaklens RR with brush for complete wetting of rusted metal surface and allowed to react it for 16-24 hours followed by cleaning the surface with wire brush and washing surface with fresh water as required to exposed reinforcement bars complete as specified. Note : Rates quoted for all items should include working upto 12m height including all necessary scaffolding , staging etc complete all as specified and as directed. HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact.
53.01
-
-
... More
M & L for Providing & applying inhibition coats/system to exposed reinforcement bars after drying & also new bars after cleaning & removing scales and rust completely as specified. Nitozinc Primer- Two component epoxy zinc rich primer supplied in 1 and 5 Litre pack, two component system based on metallic zinc and epoxy resin which on mixing gives a grey coloured liquid. An Anti corrosive coat contents Active 'Zinc-rich' system which combats corrosion by electro chemical means. having specific gravity of 1.75, Adhesive bond strength 1.5 N/mm2 Solid content- 60 %, 40 microns DFT, Fully dry/Recoatable- 45 minutes to 1 hour.Typical application includes surface preparations by cleaning steel surface to a bright condition paying particular attention to the back of exposed steel bars, mixed two components slow speed heavy duty drill fitted with a paddle, applying unbroken coat with suitable brush and allow to dry, after 30 mins apply second coat to ensure complete cover to exposed steel/ rebar etc complete. Total Dry film thickness is 40 microns. HSE Guidelines : Nitozinc Primer and Nitofl or Sol should not come in contact with the skin and eyes, or be swallowed. Adequate ventilation should be ensured and inhalation of vapours should be avoided. suitable protective clothing, gloves and eye protection shall be worn. If working in confined areas, suitable respiratory protective equipment must be used. The use of barrier creams, provide additional skin protection. Incase of contact with skin, it shall be rinsed with plenty of water, then cleansed with soap and water. Note : Rates quoted for all items should include working upto 14m height including all necessary scaffolding , staging etc complete all as specified and as directed.
53.01
-
-
... More
M & Lfor CRS steel bars, as main bars, shear connectors etc.- Cutting, fabricating new reinforcement Fe500 and fixing with old existing reinforcement (using tack welding at suitable intervals) which was reduced to 20 % or more of its original diameter as provided in original structure and additional steels as directed by EIC to be fixed with chemical anchor grout Lokfix E55- Styrene free vinyl-ester resin based cartridge system for anchoring reinforcement supplied in 300 ml cartridge with a single mixer nozzle, application includes drilling hole close to old reinforcement bar with suitable drill (Drilling of hole to be paid saperately ) as per dia of bar, cleaning the hole with wire brush and compressed air, putting Lokfix E55 with gun followed by placing rebar with slide rotational motion to avoid air void formation etc complete as directed by EIC.(i) for 8mm dia (min embedment depth 80mm) (ii) for 10mm dia (min embedment depth 90mm) (iii) for 12 mm dia ( min embedment depth 110 mm) (iv) for 16 mm dia ( min embedment depth 125 mm) . Note : Rates quoted for all items should include working upto 14m height including all necessary scaffolding , staging etc complete all as specified and as directed. HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact.
200
-
-
... More
M & L for Epoxy Bond Coat Providing and applying bond coat on the prepared surface to receive polymer modified mortar/polymer modified micro concrete, with two component epoxy based bonding coat Nitobond EP- Epoxy resin concrete bonding agent supplied in 1/2, 1 and 4 Litre packs, having specific gravity 1.15 to 1.2 gm/cc, Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days, having an over lay time of 6 hrs and 30 ̊C, High bond strength High bond strength : Bond strength is more than the tensile strength of good quality concrete, Barrier coat : Acts as a ‘barrier coat’ to the migration of chloride ions from host concrete. Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. The bond coat act as a bonding coat between old and new concrete. Typical application includes cleaning all loose dust, dirt, grease from host concrete surface by suitable means, mixing both components of bond coat by heavy duty slow speed mixer until a uniform consistency, apply unbroken coat of Nitobond EP with stiff brush covering complete area of patch repair before placing mortar or micro concrete. Item rate is inclusive of materials all labour, tools and tackles, scaffolding and transportation etc. complete as per specification and as directed by Engg.-in-charge. Note : Rates quoted for all items should include working upto 14m height including all necessary scaffolding , staging etc complete all as specified and as directed. HSE Guidelines : Recommended to wear tight-fitting, dust-resistant, chemical splash goggles if airborne dust is generated, Wear protective gloves. Wear appropriate clothing to prevent any possibility of skin contact. Barrier creams provide additional skin protection. Do not smoke during use. Maintained ample ventilation. If contact with the resin occurs, wash immediately with a strong detergent or a resin removing cream. Eye contamination must be immediately washed with plenty of water and medical treatment sought.
490.69
-
-
... More
M & L for Polymer modified Micro-concrete (upto Grade M50) Providing all scaffolding and formwork and applying Render RG- polymer modified micro-concrete supplied in 25 kg moisture resistant bag should possess following properties when mixed with clean water at w:p ratio 0.16, such as compressive strength (BS 4551-80)-50 Mpa at 28 Days, Tensile strength- 2 Mpa @ 28 Days, Flexural Strength(BS 4551-80)-5 Mpa at 28 Days, Young’s modulus-25 kN/mm2, Expansion characteristics (ASTM C827 - 1987)-Unrestrained expansion 1 to 4 %,Pressure to restrain Plastic Expansion-Approx. 0.004 N/mm2,Thermal Conductivity – 1.5 W/m ̊C, Fire rating (EN 1504 cl 5.5)- Class A1, Fresh wet density (Mixed density @27°C)- 2100 - 2200 kg/m3. Typical application include mixing whole bag with clean water about 4 litres, mixing in suitable container with heavy duty slow speed mixer machine to produce uniform, free flowing mix, pouring the same into the formwork using suitable arrangement or if required using pumping device for uniform flow of micro concrete. The side shuttering can be removed after 3 days and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate. Item rate is inclusive of materials all labour, tools and tackles, scaffolding and transportation etc. complete as per specification and as directed by Engg.-in-charge. ates quoted for all items should include working upto 14m height including all necessary scaffolding , staging etc complete all as specified and as directed. HSE Guidelines :
13.8
-
-
... More
M&L for special treatment to sunken portion (including necessary dismantling of tiles and PCC along with required PCC at site of mix 1:2:4 of required thickness) with 10mm thk plaster in CM 1:4 with WPC liquid complast 421 and applying one coat each of Nitoproof 100& Nitoproof 120 on plastered surface. Rendering again 10mm thk plast in CM 1:4 mixed with complast 421 in sunken portion of WC as base for tiling & CI pipe joint shall be filled including filling of lean concrete in 1:5:10 complete all as specified and directed.
24
-
-
... More
Demolition of Brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles .
9
-
-
... More
M&L, type-C1 1:3:6 (20mm graded aggregate) Pre-cast cement concrete block masonry with solid blocks, set in CM 1:6 exc.10 cm in width and setting in mortar, complete all as specified and as directed by Engineer-in-Charge
9
-
-
... More
Taking down cement plaster of any description on brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified & as directed.
222
-
-
... More
M&L for Providing, cement concrete in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angle complete all as spfd
1
-
-
... More
M&L for rendering 5mm thick (1:3) cement plaster newly plastered surface on ceiling fair faces of brick work or concrete surfaces even and smooth without using extra cement complete all as specified and as directed
50
-
-
... More
Material & labour for rendering 10mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished even and smooth (without using extra lime or cement) complete all as specified and directed.
72
-
-
... More
Material & labour for rendering 15mm thick in cement mortar (1:4) on fair faces of brickwork or concrete surfaces, finished even and smooth (without using extra lime or cement) complete all as specified and directed.
100
-
-
... More
M&L for preparation of newly plastered surface of wall and applying two coat of OBD over a coat primer on walls with plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth. all as specified and as directed by Engineer-in-charge
317.34
-
-
... More
M & L for preparing plastered or unplastered surfaces of old walls including Washing, rubbing down and stopping of old painted surfaces and applying two coat of OBD on walls over 1mm thick wall care putty surface to prepare the surface even and smooth all as specified and as directed by Engineer-in-charge
2190.66
-
-
... More
M&L for preparation of newly plastered surface of Ceiling and applying two coat of OBD over a coat primer on Ceiling with over plastered surface to prepare the surface even and smooth. all as specified and as directed by Engineer-in-charge
120
-
-
... More
M & L for preparing plastered or unplastered surfaces of old walls including Washing, rubbing down and stopping of old painted surfaces and applying two coat of OBD on Ceiling surface to prepare the surface even and smooth all as specified and as directed by Engineer-in-charge
852
-
-
... More
M&L for preparation of surface plastered or unplastered new plastered surface of wall and applying Finishing walls with Acrylic Smooth exterior paint of required shade : (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), as in all as specified and as directed by Engineer-in-charge
345.34
-
-
... More
M&L for preparation of surface plastered or unplastered old surface of wall and applying Finishing walls with Acrylic Smooth exterior paint of required shade : (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), as in all as specified and as directed by Engineer-in-charge
1154.66
-
-
... More
M&L for preparation of new steel and iron painted surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engr-in charge
20
-
-
... More
M&L for preparation of Old steel and iron painted surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed by Engr-in charge
109
-
-
... More
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) floors, aprons etc complete all as specified and as directed by Engr In charge
1.8
-
-
... More
M&L for 75 mm thick PCC Type B-2 (1:2:4) nominal mix with 40 mm graded coarse aggregate as per relevant IS code for floors, aprons plinth protection etc complete all as specified and as directed
18
-
-
... More
M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and weeping extra sand;
18
-
-
... More
Taking down Chowkhats or frames with shutters (without taking off shutters from the frame n exc 1.5 sq. m each complete all as specified and directed by Engr-in-Charge.
45
-
-
... More
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
135
-
-
... More
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of
Engineer-in-charge.
180
-
-
... More
S&F sheet glass ordinary quality 4.00mm thick and glazing with oil putty in squares n.exc 0.5 sqm in each pane complete all as specified and as directed by Engineer-in-charge
64.8
-
-
... More
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples
32.4
-
-
... More
Hacking out old broken glass (any thickness, size, quality or description) from wooden, metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and as directed by Engineer-in-charge
15
-
-
... More
S&F in repair sheet glass ordinary quality 4.00mm thick and glazing with oil putty in squares n.exc 0.5 sqm in each pane complete all as specified and as directed by Engineer-in-charge
15
-
-
... More
S&F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples
20
-
-
... More
Dismantling WROUGHT iron work MS of any description as in door / window frame and vertical poles as specified
1
-
-
... More
Demolition and dismantling reinforced conc in situ Roofs, floors (other than ground
floors) at any height incl all arrangements for staging etc., beams, staircases, landing, chajjas and similar suspended work reinforcement cut to facilitate demolition
2
-
-
... More
S&F 11 TO 15 mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with ashers and one hexagonal or square nut, exc 5cm long N exc 10 cm
7
-
-
... More
M&L preparation of newly steel surface of any description over 10cm width or girth not otherwise described two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified
14
-
-
... More
S&F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
108
-
-
... More
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
10.8
-
-
... More
M&L cement concrete type D2 1:4:8 (using 40mm graded stone aggregate )as in foundation, filling and mass concrete complete all as specified
2
-
-
... More
Taking down shutters but exc 1 sq. m and n exc 2 sq. m each each complete all as specified and directed by Engr-in-Charge.
27
-
-
... More
Taking down Chowkhats or frames with shutters (without taking off shutters from the frame exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and directed by Engr-in-Charge.
27
-
-
... More
M&L for II nd class hard wood Glazed and skeleton shutters 30 mm thick , open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkat complete all as specified
37.8
-
-
... More
M&L for 35mm Plain framed, factory made panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated
56.7
-
-
... More
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed by Engr-in-Charge.
17.01
-
-
... More
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engr-in-Charge.
46.8
-
-
... More
S&F aluminium anodized barrel tower bolt extruded section and fixed 150 mm long complete all as specified and directed by Engr-in-Charge.
54
-
-
... More
S&F extruded aluminium alloy handles 100mm fabricated type, anodised complete all as specified
18
-
-
... More
S&F in repair extruded aluminium alloy handles 150 mm fabricated type, anodised complete all as specified
45
-
-
... More
S&F mild steel Butt hinges medium weight ,colled rolled100mm complete all as specified
162
-
-
... More
S&F Aluminium alloy, anodised, sliding door bolt 200mm dia with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed etc complete all as specified
45
-
-
... More
S&F Floor door stopper 150mm length of aluminium alloy body and tongue with hard drawn steel spring complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F in repair aluminium anodized barrel tower bolt extruded section and fixed 150 mm long complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
S&F in repair extruded aluminium alloy handles 100mm fabricated type, anodised complete all as specified
10
-
-
... More
S&F Aluminium alloy in repair , anodised, sliding door bolt 200mm dia with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed etc complete all as specified
15
-
-
... More
S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup complete all as specified and directed by Engr-in-Charge.
9
-
-
... More
Taking up or down steel tubing & connections 15mm, including cleaning for refixing or removal to storage / away from site suitable for following bore of pipe complete all as directed & specified by Engineer-In-charge
90
-
-
... More
Taking up or down steel tubing & connections 20mm, including cleaning for refixing or removal to storage / away from site suitable for following bore of pipe complete all as directed & specified by Engineer-In-charge
84
-
-
... More
S&F tubes medium grade 15mm, galvanized with all fittings and fixed complete o wall and ceilings or laid in floors , for the following bore of tubes , complete all as specified as directed by engineer in charge
90
-
-
... More
S&F tubes medium grade 20mm, galvanized with all fittings and fixed complete o wall and ceilings or laid in floors , for the following bore of tubes , complete all as specified as directed by engineer in charge
84
-
-
... More
Refixing of 15 mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.
10
-
-
... More
Refixing of 20 mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.
5
-
-
... More
S&F in repair Pillar taps 15mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed chromium plate fancy type complete all as specified and directed by Engr-in-Charge.
9
-
-
... More
S&F in repair 15mm Stop valves, fancy type, chromium plated cast copper alloy screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed complete all as specified and directed by Engr-in-Charge.
18
-
-
... More
S&F PVC (SWR) pipes, 110 mm dia ,single socketed in any length with rubber ring joints fixed to walls complete all as specified as directed by engineer-in-charge
44
-
-
... More
S&F PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified as directed by engineer-in-charge
76
-
-
... More
S&F in repairs wash down water closet (pedestal pattern) including seat and cover Complete(excl flushing cistern or flush pipe) all as specified and directed by Engr-in-Charge.
9
-
-
... More
S&F in repairs PVC High/Low level flushing cistern 10 litres capacity including all fittings i.e float valve, syphon, flushpipe,brackets and flush pipes to pedestal pan, including all joints all as specified and directed by Engr-in-Charge.
9
-
-
... More
S&F in repairs vitreous china wash basin white flat back size550 x 400 mm excluding taps waste chain and plug and porcelain stopper but incl necessary brackets CP wastes and other fittings all as specified and directed by Engr-in-Charge.
9
-
-
... More
S & F in repairs bib taps CP Brass fancy type long shank with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm dia complete all as specified and directed by Engr-in-Charge.
27
-
-
... More
S&F in repair Chromium plated shower roses size, including fixing to steel pipe or union complete all as specified and directed by Engr-in-Charge.
9
-
-
... More
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making
connections and fixed in position complete in all respect as specified.
9
-
-
... More
M&L PVC(SWR) floor trap, plain with gratings incl jointing with solvent cement 75mm dia outlet complete all as specified and directed by Engr-in-Charge.
9
-
-
... More
S&F Grating doom 10mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed by Engr-in-Charge.
9
-
-
... More
S & F in repairs PVC connections 15mm dia with brass nut on both ends and washers 450mm long all as specified and directed by Engr-in-Charge.
18
-
-
... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and as directed by Engr-in-charge.
569.87
-
-
... More
M&L Verified Ceramic tiles light shade 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 complete all as specified and as directed by Engr-in-charge.
204
-
-
... More
M&L Glazed ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 15 mm screed in CM 1:4 complete all as specified and as directed by Engr-in-charge.
225
-
-
... More
M&L Non skid ceramic coloured tile 7 to 8 mm thick area of each tile exc 0.18 sqm but not exceeding 0.38 sqm in floor set and jointed in neat cement slurry and point in white or coloured cement to match coloured tile over 15 mm screed in CM 1:4 complete all as specified and as directed by Engr-in-charge.
63
-
-
... More
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment set in CM (1:4) complete all as spfd.
77.87
-
-
... More
Demolition of Stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc. complete all as specified and directed by Engr-In-Charge.
13.52
-
-
... More
M&L for Machine cut kota stone slab flooring 25mm thick over and including 15mm thick 1:4 cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by Engr-in charge
126
-
-
... More
M&L 20 mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr-in-Charge.
15.12
-
-
... More
S&F 500 LRotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part
4
-
-
... More
S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm , complete all as specified and directed by Engr-in-Charge.
9
-
-
... More
Dismantling water tanks and removing to store exc 250 L not Exc 500 L complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
Cleaning and removing all scale and dirt, etc, from tanks exc 250 L not Exc 500 L and from mouths of circulating pipes, etc.
5
-
-
... More
S&F in repair Drapery curtain rod/ Harrison rails of anodised aluminium alloy complete with MS brackets golden colour rings and sode caps fixed in position by drilling holes, complete all as specified and directed by Engr-in-Charge.
90
-
-
... More
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, sockets, light fittings, MCB DBs,out let boxes etc. Removing material for taking credit and making good disturbed surfaces of walls, floors, ceilings etc,complete all as specified and as directed by Engr-in-charge.
118
-
-
... More
M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 V grade confirming to IS 694 drawn through PVC conduit of suitable size heavy grade ISI marked including necessary conduit accessories, sunken type pressed steel terminal boxes with plastic laminated sheet of approved shade 3mm thick including 1.5 mm PVC insulated flame retardant copper conductor as in continuous earth wire ,complete all as specified and as directed by Engr-in-charge. for the following as given below:-
One Light/ceiling fan & exhaust fan point controlled by one switch
42
-
-
... More
One Bell point controlled by one switch .
18
-
-
... More
One 3 pin 5 Amps socket out let on independent board
20
-
-
... More
One 3 pin 5 Amps socket out let on same board
20
-
-
... More
All as per Srl Item No 92.00 above but with 2.5 Sqmm wire for 15 Amp socket outlet on independent board
18
-
-
... More
Supply & Fix switch piano flush button single pole one way 5 Amps, 250 V ,complete all as specified and as directed by Engr-in-charge.
82
-
-
... More
Supply and Fix Bell push button flush type 5 Amps ,complete all as specified and as directed by Engr-in-charge.
10
-
-
... More
Supply and Fix switch piano flush button single pole one way 15 Amps, 250 V ,complete all as specified and as directed by Engr-in-charge.
36
-
-
... More
Supply and Fix socket outlet 2 in 1,3 pin, 5A flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
40
-
-
... More
Supply and Fix socket outlet 2 in 1,6 pin, 5/15Amps flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
18
-
-
... More
Supply and Fix and fix bell buzzer, Ding Dong AC 230 volt single pole ,complete all as specified and as directed by Engr-in-charge.
10
-
-
... More
Supply and Fix fan regulator Electronic type step type for 400 watts ,complete all as specified and as directed by Engr-in-charge.
20
-
-
... More
S&F, in repair ,Ceiling rose, surface bakelite, 65mm x 50mm two to three terminals. ,complete all as specified and as directed by Engr-in-charge.
27
-
-
... More
S&F, in repair , lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting ,complete all as specified and as directed by Engr-in-charge.
15
-
-
... More
S&F in replacement of Batten type LED light fitting 1x18/20watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total harmonic distortion (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Correlated colour should be minimum 6000 degree Kelvin. ,complete all as specified and as directed by Engr-in-charge.
27
-
-
... More
M & L for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel with provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion.
Note:1.After completion if test results are nor satisfied, earthing should be redone by contractor without any extra cost. 2. Contractor should quote the rate deemed to be included with testing.
2
-
-
... More
S&F in replacement of LED bulb 5/7/9 watt, 230 Volt, 50 Hz, complete all as specified and as directed by the Engr- in- Charge. complete all as specified and as directed by the Engr- in- Charge.
15
-
-
... More
Taking down the ceiling fan /Exhaust fan from ceilling,wall,cleaning the dust,drit ,greashing,servicing ,repairing and refixing the original position ,complete all as specified and as directed by Engr-in-charge. Note:- Necessary spare for repairing will be measured and paid in respective items.
90
-
-
... More
S & F factory made sheet metal enclosure double door 415 volts ,AC TPN vertical distribution board painted with epoxy based powder coated suitable for mounting MCCB as incomer of rating upto 160 amps FP 16-36 KA and MCB SP/TP as outgoing and complete with copper Bus bars, 200A, 415V Neutral links, blanking plates, double door 4 way, with and including top and bottom removable gland with IP 43 protection and electrically connecting up ,complete all as specified and as directed by Engr-in-charge.
2
-
-
... More
S & F MCCB FP 4 pole 100 Amps 415volts 50 HZ having 16 KA ,complete all as specified and as directed by Engr-in-charge.
2
-
-
... More
Supply and fix in repairs MCB distribution board SPN 8 way 240 volts, double door with IP 42 protection duly painted with epoxy based powder coated painting suitable for mounting MCB DP/SPN as incomer and MCB SP/DP as outgoings complete with 200 Amps rated bus bar, neutral bar, earth bar connecting cable links with top and bottom removable gland plate including removing old unserviceable item complete and making good the disturbed surfaces to match with existing all as specified and directed.
4
-
-
... More
Supply & fix in repair MCB SPN 32 Amps 10 KA, "C" series, 240 volts complete all as specified and directed.
4
-
-
... More
S & F MCB SP 6 to 32 Amps 240 volts 50 HZ having 10 KA ,complete all as specified and as directed by Engr-in-charge.
24
-
-
... More
Excavation in trenches, not exceeding 1.5m wide and n.exc 10 sqm on plan and n.exc 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
12
-
-
... More
Returning filling in including spreading levelling, watering & well ramming in layers not exceeding 25 cm in soil. Complete all as specified and as directed.
9
-
-
... More
Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 metre above the starting point complete all as specified and as directed.
3
-
-
... More
Supply, spreading in trenches fine dry river sand for cable protection and removing down getting by hand complete all as specified and as directed.
3
-
-
... More
Supply and laying un reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches complete all as specified and as directed.
384
-
-
... More
Supply & laying XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cable with aluminium conductor, 1100 V grade, of 16 Sqmm x 4 core complete all as specified and as directed by Engr-in-charge.
60
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%