Military Engineer Services Tender
... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date28 Feb 2025
Closing Date28 Mar 2025
Tender Amount₹ 51,20,000
Costs
EMD
₹ 1,02,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_699713_1Tender No
85933 CWE PUNETender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per Item No.1 here-in-above but for Cardiac OPD AC plant (51TR running) at AICTS complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
All as per Item No.1 here-in-above but for PICU AC plant (17.5 TR running) at AICTS complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
All as per Item No.1 here-in-above but for Surgical ICU AC plant (44TR running) at AICTS complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
All as per Item No.1 here-in-above but for medical storage AC plant upto 5TR (running) complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
All as per Item No.1 here-in-above but for DIAC AC plant MINTSD (40TR running) complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
All as per Item No.1 here-in-above but for Negative pressure room at AICTS (4TR running) complete all as specified and directed by Engr-in-Charge.
Note For item 1.00 to 8.00 above : PVC sheets reqd for ingress Protection of medical equipments will be arranged by the contractor and its cost shall deemed to be included in unit quoted rate.
1
-
-
... More
S&F in replacement for brass ball valve from liquid line of size 1-1/8" from the liquid line in a suitable way including necessery jointing and joining material complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
S&F in replacement for brass ball valve from liquid line of size 7/8" from the liquid line in a suitable way including necessery jointing and joining material complete all as specified and directed.
3
-
-
... More
Taking out Old Unserviceable compressor oil, supply and fill by topping up compressor oil N-68 complete all as specified and as directed.
(NOTE : Make and sample of compressor oil shall be got approved by contractor from GE prior procurement.)
150
-
-
... More
S&F in replacement following spare part of Compressor compatible to existing model No. FK - 450 & 500 make : Frizking complete all as specified and as directed.
-
-
-
... More
(a) Piston Ring
8
-
-
... More
(b) Strainer suction assembly
5
-
-
... More
(c) Oil Pump Assembly
5
-
-
... More
(d) Oil filter
4
-
-
... More
(e) 'O' Ring set
3
-
-
... More
(f) Gasket set
4
-
-
... More
(g) Suction & Discharge valve reeds.
6
-
-
... More
S&F in replacement of following spare parts of Compressor compatible to existing model No. 05040S make : Voltas complete all as specified and as directed.
-
-
-
... More
(a) Strainer suction assembly
4
-
-
... More
(b) Oil Pump Assembly
3
-
-
... More
(c) Oil filter
4
-
-
... More
(d) 'O' Ring set
6
-
-
... More
(e) Gasket set
5
-
-
... More
(f) Suction & Discharge valve reeds
4
-
-
... More
(g) Cap Control valve without bellow
3
-
-
... More
M&L for Refrigerant gas R-22 all as specified and directed.
250
-
-
... More
M&L for Refrigerant gas R-134a all as specified and directed.
30
-
-
... More
M&L for Refrigerant gas R-407a all as specified and directed.
90
-
-
... More
M&L for Refrigerant gas R-404a all as specified and directed.
(NOTE for Ser. Item No. 14.00 to 17.00 above : Make of refrigerent gas shall be got approved by Contractor from GE prior procurement.)
110
-
-
... More
Supply and fix in replacement of new shaft seal assembly for Compressor compatible to existing model No. FK-450, & 500 of make : Frizking complete all as specified and as directed.
6
-
-
... More
All as per item No 18.00 above but for Compressor compatible to existing model No. 05040S, Make : Voltas complete all as specified and as directed.
4
-
-
... More
Supply and fix in replacement to suction and discharge valve of following models of compressor by means of replacing the teflon washer sheet, suction and discharge valve ring, spring, 'O' Rings, gasket complete and testing for proper holding of Compressor all as directed by Engr-In-Charge compatible to existing model FK - 450 & 500 of Make:Kirloskar
6
-
-
... More
All as per item no 20.00 above but for Compressor compatible to existing model 05040S, Make : Voltas complete all as specified and as directed.
4
-
-
... More
S&F in replacement of Oil pressure cut Off switch compatible to existing make complete all as specified and directed.
5
-
-
... More
S & F in replacement of compound gauge for low pressure 32 to 250 Kg/cm2 working on F-12 and F-22 gas compatible to existing Make : FIEBIG complete all as specified and as directed.
6
-
-
... More
S & F in replacement of HP/LP cut off switch compatible to existing make complete all as specified and directed.
5
-
-
... More
S&F in replacement pressure gauge suitable for working on F-22 & F-12 gas of ranges 0-300 Kg/Cm2as per site requirement compatible to existing Make complete all as specified and as directed.
5
-
-
... More
S & F in replacement of thermostatic expansion valve of suitable flare size including Brazing, Welding work etc. for the following type/model working on F -12,F-22& 134a gas complete all as directed by EIC compatible to existing model HVE-16, CP-100 of Make : Sporlon.
3
-
-
... More
All as per item No. 26.00 above but Thermostatic expansion valve compatible to existing model SVE-8, VCP-100 Make : Sporlon complete all as specified and as directed.
3
-
-
... More
Supply, Install, test and commissioning in replacement of compressor for Package type AC 5 to 12 TR compatible to existing model DPA-1202 Make - BlueStar complete all as specified and as directed.
6
-
-
... More
S & F in replacement of thermostatic expansion valve of suitable Flaire size including brazing/ welding works etc for Package type AC 6 TR to 12 TR compatible to existing Make complete all as specified and as directed.
2
-
-
... More
All as per item No 29 but for package type AC 10 TR compatible to existing one complete all as specified and as directed.
2
-
-
... More
S & F in replacement of Solenoid valve for package AC 6 TR all as specified and directed.
4
-
-
... More
S & F in replacement of Solenoid valve for package AC 10 TR all as specified and directed.
4
-
-
... More
S & F in replacement of Solenoid coil of suitable size compatible to existing Make one all as specified and directed.
8
-
-
... More
S & F in replacement of strainer for 6 TR Package type ACs complete all as specified and directed.
4
-
-
... More
S & F in replacement of strainer for 10 TR Package type ACs complete all as specified and directed.
4
-
-
... More
S & F in replacement of unserviceable/leakage Service Valve suitable for 6 TR capacity Package AC Plant complete all as specified and as directed.
2
-
-
... More
S & F in replacement of unserviceable/leakage Service Valve suitable for 10 TR capacity Package AC Plant complete all as specified and as directed.
2
-
-
... More
S&F in replacement cooling Coil 75 TR and above capacity by means of opening the cooling coil, with pressure air and water, charge the Nitrogen gas for pressure leak test complete and repairing the same by means of soldering / brazing, repairs to drain water bottom portion by means of replacement of old rusty GI Sheets with 22 gauge of new GI sheet complete with fabrication work etc of size 2400x1800 MM and making good thermal insulation with glass wool, wire mesh plaster for blower portion complete all as specified and directed.
2
-
-
... More
S&F in replacement of cooling Coil 50 to 60 TR capacity by means of opening the cooling coil, with pressure air and water, charge the Nitrogen gas for pressure leak test complete and repairing the same by means of soldering / brazing, repairs to drain water bottom portion by means of replacement of old rusty GI Sheets with 22 gauge of new GI sheet complete with fabrication work etc of size 2400x1800 MM and making good thermal insulation with glass wool, wire mesh plaster for blower portion complete all as specified and directed.
1
-
-
... More
S&F in replacement of cooling Coil 30 to 35 TR capacity by means of opening the cooling coil, with pressure air and water, charge the Nitrogen gas for pressure leak test complete and repairing the same by means of soldering / brazing, repairs to drain water bottom portion by means of replacement of old rusty GI Sheets with 22 gauge of new GI sheet complete with fabrication work etc of size 2400x1800 MM and making good thermal insulation with glass wool, wire mesh plaster for blower portion complete all as specified and directed.
3
-
-
... More
Disconnecting & Dismantling the old Power cables, Circuit wiring and controlling accessories like MCCBs, Contactors, relays and timers from the existing pannel board of 50 to 80 TR capacity AC plant and replacing the power cables with new copper mulistranded power cable 16 Sqmm and circuit wiring with copper multi stranded power cable 4 sqmm including repairs/ replacing Contactors, timers and Relays complete all as specified and directed.
(Note:- Contactor ML 1.5, ML 2, ML 3, Timers and relays will be measured and paid separately under respective items of BOQ.)
5
-
-
... More
Disconnecting & Dismantling the old Power cables, Circuit wiring and controlling accessories like MCCBs, Contactors , relays and timers from the existing pannel board of 20TR capacity AC plant replacing the power cables with new copper mulistranded power cable 10 Sqmm and circuit wiring with copper multi stranded power cable 4 sqmm including repairs/ replacing Contactors, timers and Relays complete all as specified and directed.
(Note:- Contactor ML 1.5, ML 2, ML 3, Timers and relays will be measured and paid separately under respective items of BOQ.)
2
-
-
... More
Disconnecting & Dismantling the old Power cables, Circuit wiring and controlling accessories like MCCBs, Contactors, relays and timer from the existing pannel board of 30 to 35 TR capacity AC plant and replacing the new Copper multi strand Power cables 10 Sqmm, Circuit wiring with Copper multi strand Power cables 4 Sqmm including controlling accessories like MCCBs, Contactors, relays and timer etc. complete all as specified and directed.
(Note :- Controlling accessories like MCCBs, Contactors, relays and timer will be measured and paid separately under respective items of BOQ.)
4
-
-
... More
Disconnecting & Dismantling the old Power cables, Circuit wiring and controlling accessories like MCCBs, Contactors, relays and timer from the existing pannel board of Cold storage AC plant upto 10 TR capacity and replacing the new Copper multi strand Power cables 6 Sqmm, Circuit wiring with Copper multi strand Power cables 4 Sqmm including controlling accessories like MCCBs, Contactors, relays and timer etc. complete all as specified and directed.
(Note :- Controlling accessories like MCCBs, Contactors , relays and timer will be measure and paid separately under respective items of BOQ.)
2
-
-
... More
Supply and fix in replacement Ammeter as per sample of 0-30 Amp all as specified and directed
6
-
-
... More
All as per item no 45 as above as per sample of 0-50 Amp all as specified and directed.
8
-
-
... More
S&F in replacement of contactor ML-1.5 with coil voltage 230 volt AC all as specified and directed.
3
-
-
... More
S&F in replacement of contactor ML-2 with coil voltage 230 volt AC all as specified and directed.
5
-
-
... More
S&F in replacement of contactor ML-3 with coil voltage 230 volt AC all as specified and directed.
3
-
-
... More
S&F in replacement contactor MNX 25 ,3 pole with coil voltage 230 volt AC all as specified and directed.
8
-
-
... More
S&F in replacement of contactor MNX 32 ,3 pole with coil voltage 230 volt AC complete all as specified and directed.
8
-
-
... More
S&F in replacement of ADD ON 2NO (Normally open) + 2NC (Normally closed) for MNX contactor all as specified and directed.
4
-
-
... More
Supply and fix in replacement CT's 100/5, 5 VA complete all as specified and directed.
5
-
-
... More
S&F in replacement of electronic timers, Model GT-200 240 volts AC all as specified and directed.
2
-
-
... More
S&F in replacement of electronic star delta timers / Timer ET, 240 volts AC all as specified and directed.
5
-
-
... More
S&F in replacement of bimetal overload relay, direct mounting type suitable for ML series of range 1.5 to 2.5 Amps,all as specified and directed.
8
-
-
... More
S&F in replacement of bimetal overload relay, direct mounting type suitable for ML series of range 2.5 to 4.1Amps all as specified and directed.
4
-
-
... More
S&F in replacement of bimetal overload relay, direct mounting type suitable for ML series of range 4 to 6.5Amps all as specified and directed.
8
-
-
... More
S&F in replacement of bimetal overload relay, direct mounting type suitable for ML series of range 6 to 10 Amps all as specified and directed.
6
-
-
... More
S&F in replacement of bimetal overload relay, direct mounting type suitable for ML series of range 9 to 14 Amps all as specified and directed.
2
-
-
... More
S&F in replacement of bimetal overload relay, direct mounting type suitable for ML series of range 13 to 21 Amps all as specified and directed.
3
-
-
... More
S&F in replacement of bimetal overload relay, direct mounting type suitable for ML series of range 24 to 32 Amps all as specified and directed.
5
-
-
... More
S&F in replacement of bimetal overload relay, direct mounting type suitable for ML series of range 28 to 42 Amps all as specified and directed.
3
-
-
... More
S&F in replacement of MCCB 200 Amp, 3 pole 25 KA breaking capacity, 440V, AC complete all as specified and directed.
2
-
-
... More
S&F in replacement of MCCB 250 Amp, 3 pole 25 KA breaking capacity, 440V, AC complete all as specified and as directed.
1
-
-
... More
S&F in replacement of MCCB 100/125 Amp, 3 pole 25 KA breaking capacity, 440V, AC complete all as specified and directed.
3
-
-
... More
S&F in replacement of MCCB 63 Amp, 3 pole 16 KA breaking capacity, 440V, AC complete all as specified and directed.
2
-
-
... More
S&F in replacement of MCB TPN 63 Amp, 3 pole 10 KA breaking capacity 440V, AC complete all as specified and directed.
3
-
-
... More
S&F in replacement of MCB TPN 40 Amp, 3 pole 10 KA breaking capacity 440V, AC complete all as specified and directed.
4
-
-
... More
S&F in replacement of MCB TPN 32 Amp, 3 pole 10 KA breaking capacity 440V, AC complete all as specified and directed.
3
-
-
... More
S & F in replacement of unserviceable Solid state indicating lamps 230 Volt AC with RYB and green indication (LED type ) including adopter ring / washer and cable connection compatible to existing Make: Altos complete all as specified and as directed.
30
-
-
... More
S&F in replacement of digital type temperature indicator including sensor and multicore copper cable ( Length of cable as per requirement) complete all as specified and as directed.
3
-
-
... More
Taking out burnt/unserviceable fan/blower motor and rewinding of Package type AC fan/blower motor double shaft single/double speed, single phase, 230 VAC complete suitable fixing arrangement for existing phase and suitable for upto 5 to 12 TR capacity Package AC all as specified and directed.
3
-
-
... More
Supplying & laying in replacement insulating mat of size 2000x1000x12mm thick with ISI mark of LT side all as specified and directed.
4
-
-
... More
S&F in replacement of HP/LP cut off switch, MP-15 complete all as specified and as directed.
2
-
-
... More
S&F in replacement single phase preventer of model VSP D-1A/SP-3 all as specified and directed.
4
-
-
... More
S&F in replacement Contactor 3T II all as specified and directed
3
-
-
... More
S&F in repairs to cooling tower by means of replacement of unserviceable filters, cleaning the filters and replacing the Gun metal / Nylon Nozzles compatible to existing one etc complete all as specified and directed.
(Note :- Gun metal/Nylon Nozzles shall be measured and paid separately under respective items of BOQ)
8
-
-
... More
S&F in replacement of Nylon Nozzles compatible to existing one complete all as specified and directed.
50
-
-
... More
Taking down motor 40HP from foundation by disconnecting electrically and mechanically, transporting to workshop for rewinding with ISI marked copper winding wire, ISI marked insulating paper, varnish, replacement of bearings two Nos. of DE and NDE etc transporting back the motor, installing on foundation, aligning the same reconnecting electrically and mechanically and testing on Full load for two hours for satisfactory functioning complete all as specified and directed.
1
-
-
... More
All as per Item No. 80.00 above but for 30HP motor complete all as specified and directed.
1
-
-
... More
All as per Item No. 80.00 above but for 25HP motor complete all as specified and directed.
1
-
-
... More
All as per Item No. 80.00 above but for 20HP motor complete all as specified and directed.
1
-
-
... More
All as per Item No. 80.00 above but for 7.5 HP motor complete all as specified and directed.
2
-
-
... More
All as per Item No. 80.00 above but for 5 HP motor complete all as specified and directed.
1
-
-
... More
All as per Item No. 80.00 above but for 2 HP motor complete all as specified and directed.
2
-
-
... More
M&L for dismantling the AHU complete and taking out blower shaft for repairs and transport to workshop for weight balancing (Dynamic) and reassembling the complete unit including replacement of old worn out bearings, with housing & sleeves complete for capacity of central AC plant 20 TR to 40 TR capacity complete all as specified and directed.
1
-
-
... More
All as per item No. 87.00 above but Capacity of 45 TR to 95 TR capacity complete all as specified and directed.
1
-
-
... More
S & F in replacement of Condenser unit Suitable for upto 12 TR capacity Package AC all as specified and directed.
2
-
-
... More
Taking down the old filters of any type and size from AHU/duct of Central type AC plant at MH (CTC),CH(SC), ALC and MITS&D by means of unservicing nut bolts, washers etc.including cleaning of AHU/duct as directed by Engineer-in-Charge
88
-
-
... More
S&F in replacement of filters "HEPA" (Absolute) Model 131-C with fibre glass paper filtering media ,capacity 1000CFM efficiency 99.97% down to particle size of 0.3 microns aluminium frame of nominal size 24"x24"x6" or nearest as directed by Engineer-in-Charge
14
-
-
... More
S&F in replacement filter "Microvee" type non woven fabric filter media efficiency 99.98% down to particle size of 5 microns, MS casing flanged type of nominal 24"x24"x6" or nearest complete all as specified and directed.
14
-
-
... More
All as per Item No. 92.00 above but of size 22.5"x 22.5"x 3" or nearest size complete all as specified and directed.
6
-
-
... More
All as per Item No. 92.00 above but of size 17" x 24" x 2" or nearest size all as specified and directed.
6
-
-
... More
S&F in replacement of panel air filters, dry type, washable rated air flow capacity 1600 CFM efficiency 99.9% down to article size 17" x 24" x 2" or nearest size complete all as specified and directed.
4
-
-
... More
S&F in replacement of panel air filters, dry type, washable rated air flow capacity 1600 CFM efficiency 99.9% down to article size 24" x 24" x 1.8" or nearest size complete all as specified and directed.
6
-
-
... More
S&F in replacement of panel air filters, dry type, washable rated air flow capacity 1600 CFM efficiency 99.9% down to article size 24" x 20" x 4" or nearest size complete all as specified and directed.
26
-
-
... More
S&F in replacement of panel air filters, dry type, washable rated air flow capacity 1600 CFM efficiency 99.9% down to article size 42" x 26" x 2" or nearest size complete all as specified and directed.
4
-
-
... More
S&F in replacement of panel air filters, dry type, washable rated air flow capacity 1600 CFM efficiency 99.9% down to article size 32" x 20" x 0.2" or nearest size complete all as specified and directed.
8
-
-
... More
Supply, Install, testing and commission in replacement of Hepa plenum with Hepa Filter (99.97% particulate efficiency) Size : 305mmx610mmx69mm for each bed side, HEPA shall made up of high quality aluminium diffuser grill to secure the unidirectional air flow according to EN ISO 14644. MOC of Plenum & diffuser grill - SS 304, matt polish, sheet thickness 0.8mm complete all as specified and directed.
45
-
-
... More
All as per Ser. Item 100.00 above but of size 610mmx1220x75mm complete all as specified and directed.
8
-
-
... More
All as per Ser. Item 100.00 above but of size 610mmx915 x 75mm all as specified and directed.
6
-
-
... More
S&F in repair V belt A-28 compatible to existing one complete all as specified and directed.
4
-
-
... More
S&F in repair V belt A-32 compatible to existing one complete all as specified and directed.
4
-
-
... More
S&F in repair V belt B-38 compatible to existing one complete all as specified and directed.
6
-
-
... More
S&F in repair V belt B-39 compatible to existing one complete all as specified and directed.
8
-
-
... More
S&F in repair V belt A-41 compatible to existing one complete all as specified and directed.
5
-
-
... More
S&F in repair V belt B-53 compatible to existing one complete all as specified and directed.
3
-
-
... More
S&F in repair V belt B-60 compatible to existing one complete all as specified and directed.
8
-
-
... More
S&F in repair V belt B-73 compatible to existing one complete all as specified and directed.
6
-
-
... More
S&F in repair V belt B-76 compatible to existing one complete all as specified and directed.
4
-
-
... More
S&F in repair V belt B-78 compatible to existing one complete all as specified and directed.
12
-
-
... More
S&F in repair V belt B-82compatible to existing one complete all as specified and directed.
8
-
-
... More
S&F in repair V belt C-82compatible to existing one complete all as specified and directed.
6
-
-
... More
S&F in repair V belt B-88compatible to existing one complete all as specified and directed.
2
-
-
... More
S&F in repair V belt B-92compatible to existing one complete all as specified and directed.
4
-
-
... More
S&F in repair V belt B-102 compatible to existing one complete all as specified and directed.
6
-
-
... More
S&F in repair V belt B-105 compatible to existing one complete all as specified and directed.
5
-
-
... More
S&F in repair V belt B-108 compatible to existing one complete all as specified and directed.
10
-
-
... More
S&F in repair V belt B-110 compatible to existing one complete all as specified and directed.
8
-
-
... More
S&F in repair V belt C-144 compatible to existing one complete all as specified and directed.
6
-
-
... More
S&F in replacement of framed chicken mesh with 25mmx3mm flat iron frame in corner and center with stiffners of Size complete all as specified and directed.
30
-
-
... More
M&L for dismantling the condenser inlet pipe and outlet pipe for opening both end plates of condenser by loosing nuts bolts.Brushing the copper tubes with the help of nylon brush to remove the scale without damaging the surface and cleaning the tube with descaling regent Dilute HCL or equivalent) for Compressor model FK - 450 & 500 existing Make : Kirloskar all as directed by EIC.
4
-
-
... More
All as per item No. 123.00 but for existing model 05040S Make : Voltas complete all as specified and directed.
2
-
-
... More
All as per item No. 123.00 but for existing model DXT type Seal type all as specified and directed.
1
-
-
... More
M&L for cleaning the cooling tower of any type by removing all type of fins and scraping the Fungus of fins and make up tank by applying Dilute HCL solution and drawing out including cleaning and filling with fresh water specified and as directed by Engineer-in-charge.
8
-
-
... More
Taking down carefully defective /unserviceable Liquid line valve assembly complete from existing installed at site by cutting the line and supply and fix new Liquid line valve assembly by doing brazing/welding specified and as directed by Engineer- in- charge.
18
-
-
... More
M & L for preparing existing surfaces of steel exc 10cm width or girth by scrapping rusted part and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
25
-
-
... More
M & L for replacement of FRP louvers of size 1220 x 330 x 3mm thick complete all as specified and directed
36
-
-
... More
S&F in replacement of contactor 70 Amps, 3 pole with coil voltage 230 volt AC all as specified and directed.
8
-
-
... More
Surface excavation not exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
40
-
-
... More
S&F in replacement of Mild steel chequered plate 10mm thick for ducting edges beaded if directed,holes punched included round headed screws complete all as specified and directed by Engn-In-Charge.
60
-
-
... More
Suplly and fixing in replacement of Cast Iron butterfly valve of 100mm dia as per IS: 13095, having epoxy coated disc, carbon steel shaft, EPDM/nitrile rubber field replacible body lining and of approved make. including a set of MS flanges, required nos of nut & bolts complete all as specified and directed.
4
-
-
... More
Supply & fixing in replacement of 100 mm dia pot type strainers with copper cage and flange type complete all as per direction of Engr- in -charge.
4
-
-
... More
Supply and lay in trenches/on ground, jointing, testing and commissioning in replacement of MS pipe heavy grade including all necessary pipe fittings/accessories like socket, unions, tees elbows etc of the size 150 mm bore all as specified and directed.
40
-
-
... More
All as per item No. 135.00 but size 100 mm bore all as specified and directed.
60
-
-
... More
Maintenance and Servicing including attending faults on day to day basis of AC plant of 40 TR including taking down unserviceable parts, refixing new parts wherever necessary complete including leak testing with nitrogen gas complete,cleaning all type of filters including all accessories and cleaning and maintaining equipment and plant room as specified and directed by Engineer in charge and testing the plant for satisfactory. Make : Kirloskar Location - MINTSD DIAC Bldg
11
-
-
... More
All as per item No 137.00 above but for AC plant Cap 3TR compatible to existing Make : Frizking complete all as specified and directed.
Location : AICTS med store
11
-
-
... More
All as per item No 137.00 above but for AC plant Cap 80TR compatible to existing Make : Voltas complete all as specified and directed.
Location : CTC OT 1& 2
11
-
-
... More
All as per item No 137.00 above but for AC plant Package type, Cap 66TR complete all as specified and directed.
Location : CTC ICU/ NICU
11
-
-
... More
All as per item No 137.00 above but for Negative pressureAC plant Package type, Cap 4TR complete all as specified and directed.
Location : AICTS
11
-
-
... More
All as per item No 137.00 above but for Cardiac ICU AC plant, Cap 34TR complete all as specified and directed.
Location : AICTS
11
-
-
... More
All as per item No 137.00 above but for Cardiac OPD AC plant, Cap 51 TR complete all as specified and directed.
Location : AICTS
11
-
-
... More
NOTE FOR SER. ITEM No. 137.00 TO 143.00 ABOVE :-
(a) Spares required for the above maintenance shall be measured & paid as Supply only under appropriate items of Schedule 'A'.
(b) Every day checklist as approved by Engr-in-charge has to be produced by technician giving the details of the AC plant
(c) Routine checking/testing/servicing of the AC plants and Oxygen plants shall be done on weekly basis including greasing and oiling, if not Rs. 3000 will be imposed as penalty for every week & machinery missed and completion of servicing be produced to Engr-In-Charge.
(d) Every day one technician has to be deployed for day to day maint and rectification of faults if any and failing which Rs.800 will be charged as penalty for every day. Technician should report attendance to Engr-in-charge.
(e) Providing Gland, oil, gresaing and other neccessary items for better functioning of machinery to be provided by the contractor and cost shall be deemed to be included in the per month maintenance of the machinery.
(f) The rates are inclusive complete testing of machine to the entire satisfaction of Engr-In-Charge.
-
-
-
... More
Supply and fix in replacement of a suitable 20 way copper distributer for cooling coil of AHU for 50 TR AC plant all as specified and directed.
2
-
-
... More
M&L for Caliberation micro processor system of Voltas compressor or and seting the same to for smooth function of compressor and AC plant from autherised agency complete all as specified and directed.
Location - MH (CTC) / MITS & D
1
-
-
... More
S&F in repairs PVC insulated FRLS copper wire 1.5sqmm, 1100V grade of colour code red, yellow, blue,black or green laid down from motor to panel or inside panel all as specified and directed.
300
-
-
... More
S&F in repairs PVC insulated FRLS copper wire 2.5sqmm, 1100V grade of colour code red, yellow, blue, black or green all as specified and directed.
250
-
-
... More
S&F in repairs PVC insulated FRLS copper wire 4.0sqmm, 1100V grade of colour code red, yellow, blue, black or green all as specified and directed.
200
-
-
... More
S&F in repairs PVC insulated FRLS copper wire 6.0sqmm, 1100V grade of colour code red, yellow, blue, black or green all as specified and directed
150
-
-
... More
S&F in repairs PVC insulated FRLS copper wire 10.0sqmm,1100V grade of colour code red, yellow, blue, black or green all as specified and directed
200
-
-
... More
M&L for painting of panels,cooling water pipe line,and other connected items ,compressors and motor of central AC plant of capacity upto 50 TR with synthetic enamel paint of approved colour after preparartion of surface all as specified and directed by engineer in charge.
4
-
-
... More
M&L for painting of panels,cooling water pipe line,and other connected items ,compressors and motor of central AC plant of capacity 51 to 90 TR with synthetic enamel paint of approved colour after preparartion of surface all as specified and directed by engineer in charge.
6
-
-
... More
Supply and fix in repairs/replacement of Variable frequency drive (VFD) input power 380-480V, 50/60Hz, 51.9A, 22 KW,30 HP compatible to existing Model OPTIDRIVE E3 Make : Invertek or equivalent complete all as specified and directed.
4
-
-
... More
M& L for duct thermal insulation class O Nitrile rubber based thermal insualtion 19 mm thick with treated woven glass fibre covering of 0.18mm thick density of 200+20 GSM Tensile strength 275+25 kg/mm for exposed to sun applictaion (green colour) including fixing with adhesive which is specifically formulted for duct insulation which shall be free from benzene joints shall be fixed with self adhesive ability to ensure 100% leak proof, including taking out existing unsv insulation material,celaning the dust suraface complete all as specified by OEM complete all as specified and directed by Engr-In-Charge.
100
-
-
... More
S&F in replacement of canvas connection (To reduce ducting vibration fitting on machine between ducting) including nuts,bolts and washers all as specified and directed by Engr-In-charge.
15
-
-
... More
Supply and fix in replacement of supply air diffuser for the 4 way square,air terminal shall be aluminium powder coated construction with easily removable central core & 4 way unifrom air distribution.Volume control damper to be of opposed blade,nylon geared with aerofill blades & blank matt powder coated(out to out ) size 600mm X 600mm with full louvers with required duct connection size(as per approved layouts) & as per approved sample (colour to match the requirements) complete all as specified and directed by Engr-In-Charge.
12
-
-
... More
Supply and fix in replacement of return air diffuser for the 4 way square,air terminal shall be aluminium powder coated construction with easily removable central core & 4 way unifrom air distribution.Volume control damper to be of opposed blade,nylon geared with aerofill blades & blank matt powder coated(out to out ) size 600mmX 600mm with full louvers with required duct connection size(as per approved layouts) & as per approved sample (colour to match the requirements) complete all as specified and directed by Engr-In-Charge.
12
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%