Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical Works
Eprocure
Opening Date1 Feb 2025
Closing Date22 Feb 2025
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Summary

Repairs Replacement Of Lt Ug Cables, Jointing Works And Other Misc Works Of Em Installation At Ra ,

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, laying and testing LT XLPE insuated PVC bedded galvanised steel strip or wire armoured earthed electric power cable with aluminium conductor 1100 volts grade, heavy duty in trenches/along pole or wall of 10 Sqmm 2 core complete all as specified and directed by Engineer-in-Charges. Note:- 1. Excavation and earth work, sand cushioning, brick pipes, clamps, and cable joint shall be measured and paid separetely under respective items :-

400

-

-

... More
All as per item No 4 above, but of size 16 Sq mm 2 core

500

-

-

... More
All as per item No 4 above, but of size 16 Sq mm 4 core

300

-

-

... More
All as per item No 4 above, but of size 25 Sq mm 4 core

350

-

-

... More
All as per item No 4 above, but of size 35 Sq mm 3.5 core

400

-

-

... More
All as per item No 4 above, but of size 50 Sq mm 3.5 core

300

-

-

... More
All as per item No 4 above, but of size 70 Sq mm 3.5 core

155

-

-

... More
All as per item No 4 above, but of size 95 Sq mm 3.5 core

200

-

-

... More
All as per item No 4 above, but of size 120 Sq mm 3.5 core

150

-

-

... More
All as per item No 4 above, but of size 185 Sq mm 3.5 core

65

-

-

... More
Re- laying LT XLPE insuated PVC bedded galvanised steel strip or wire armoured earthed electric power cable with aluminium conductor 1100 volts grade, heavy duty in trenches/along pole or wall of16 Sq mm -35 Sqmm 3.5/4 core complete all as specified and directed by Engineer-in-Charges. Note:- 1. Excavation and earth work, sand cushioning, brick pipes, clamps, and cable joint shall be measured and paid separetely under respective items.

50

-

-

... More
All as per item No 14 above but of size 50 Sq mm-70 sqmm 3.5/4 core

30

-

-

... More
All as per item No 14 above but of size 95 sqmm-240 Sq mm 3.5/4 core

30

-

-

... More
Excavation in trenches by mechnical means (hydraulic excavator) not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all kind of soil complete all as specified and as directed by EIC..

485.39

-

-

... More
M&L for Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil. complete all as specified and directed Engr-in-Chrage.

364.04

-

-

... More
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed Engr-in-Chrage.

121.35

-

-

... More
Supply & laying in repair 40 mm bore galvanized steel tubing "light grade" with all fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified & directed by Engr-in-Chrage.

30

-

-

... More
All as per item No 20 above but of size 50 mm bore

25

-

-

... More
All as per item No 20 above but of size 80 mm bore

20

-

-

... More
All as per item No 20 above but of size 100 mm bore

10

-

-

... More
Road cutting for UG cable under road/railway crossing, pavement, hardstanding by mannually means, protection GI pipe for cable of required dai and making it good to match with the adjoining surface/structure for after cable passing complete all as specified and directed. Note : GI pipe and PCC will be measured and paid against respective items.

50

-

-

... More
M&L for tesitng of faulty LT XLPE/PVC armoured cable of any size and any position at CAD Pulgaon by using LT voltage testing kit installed on movable vehicle complete all as specified and directed by Engr-in-Chrage. Note : This job includes cost of vehicle transport from Nagpur to Pulgaon and back

10

-

-

... More
Supply & Fixing in repair 6 -16 Sqmm 4 Core cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 and 4 core XLPE armoured aluminium conductor cable complete all as specified and directed by Engr-in-Chrage. Note : Excavation, returning filling, sand brick and removel shall be measured and paid separatly under relevant item of this BOQ

5

-

-

... More
All as per item No 26 above but for cable 25 to 50 sq mm 3.5 core

6

-

-

... More
All as per item No 26 above but for cable 70 to 120 sq mm 3.5 core

8

-

-

... More
All as per item No 26 above but for cable 150 to 185 sq mm 3.5 core

3

-

-

... More
All as per item No 26 above but for cable 240 to 300 sq mm 3.5 core

3

-

-

... More
Dismantling and taking out the existing unserviceable (damaged/broken) or serviceable tilted Panel of any type and any size, from Location and removal from site all as directed by Engr-in-Chrage.

5

-

-

... More
Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation of pole upto ground level complete all as directed by Engr-in-Chrage.

12

-

-

... More
PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in coping/plinth block including necessary form work all as directed by Engr-in-Chrage.

2

-

-

... More
Supply install, testing and commissioning Out door, in replacement of LT Distribution Panel Feeder Pillar (CPRI approved) Cubicle type,IP-56,outdoor type confirming to IS: 61439 Part I & II factory fabricated made out of outer cover with 3 mm thick CRCA sheet & inner cover with 2mm thick CRCA sheet of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing MCCBs feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. The cubicle shall have a bottom and four legs (400mm long) of size 50x 50x6 mm, The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following all as specified and directed by EIC. Note :- PCC work will be measured and paid separately. (I) Incoming :- (i) Aluminium busbar, 4 Pole, 300 Amps (ii) MCCB 4P, 200A, 25 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 01 No. (iii) Ammeter Digital type, CT operated 0-630A range, MAKE: SECURE / L&T (with selector switch and CT) - 01 Set (iv) Volt Meter Digital type 0-500 V range, Make:SECURE / L&T (With selector switch) - 01 No. (iv ) Indicating Lamp LED type 240 V 50 HZ AC supply (Make BCH/SIEMENS/L&T) set of three colour (RYB)-01 set. (II) Outgoing :- (i) MCCB 4P, 63A, 25 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 04 Nos. (ii) MCB TPN, 32A, 10 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 04 Nos.

3

-

-

... More
Supply install, testing and commissioning Out door, in replacement of LT Distribution Panel Feeder Pillar (CPRI approved) Cubicle type,IP-56,outdoor type confirming to IS: 61439 Part I & II factory fabricated made out of outer cover with 3 mm thick CRCA sheet & inner cover with 2mm thick CRCA sheet of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing MCCBs feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. The cubicle shall have a bottom and four legs (400mm long) of size 50x 50x6 mm, The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following all as specified and directed by EIC. Note :- PCC work will be measured and paid separately. (a) incoming (i) Aluminium busbar, 4 Pole, 300 Amps (ii) MCCB 4P, 160A, 25 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 01 No. (iii) Ammeter Digital type, CT operated 0-630A range, MAKE: SECURE / L&T (with selector switch and CT) - 01 Set (iv) Volt Meter Digital type 0-500 V range, Make:SECURE / L&T (With selector switch) - 01 No. (iv ) Indicating Lamp LED type 240 V 50 HZ AC supply (Make BCH/SIEMENS/L&T) set of three colour (RYB)-01 set. (b) Outgoing :- (i) MCCB 4P, 63A, 25 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 01 Nos. (ii) MCB TPN, 32A, 10 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 04 Nos.

3

-

-

... More
M& L for taking out LT feeder panel front and back type opening replace old clamps and fix new hinges by drilling or belding as per condition , replaced burnt out lugs and insulation , proper, insulation taping to XLPE cable and painting inner and outer side , top and bottam, including cleaning of grass around, from the panel till 2mtr and from road to panel for easy operation complete all as specified and drirected by Engr-In-Charge

5

-

-

... More
M& L for taking out LT feeder panel all cables from loops, for fixing GI Pipe for cable protection and making new foundation in place of broken foundation with PCC 1:4:8 in 40 mm graded stone aggregate and re-fixing all cables with proper lugs after inserting through GI pipe complete. all as specified and directed by EIC. Note :; PCC shall be measured and paid in the respective items.

5

-

-

... More
S&F for Ampere meter square type 96 x 96 mm 0-400 Amps with CT and selector switch (Digital type)

8

-

-

... More
S&F for Voltmeter square type 96 x 96 mm 0-500 V with inbuilt selector switch - ( Digital type)

8

-

-

... More
S&F for Indicator lamp neon/LED type (set of three )

10

-

-

... More
S& F for Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade FRLSH type with copper conductor multistranded cable not less than 1.5 sqmm with lugs on both ends of cable. all as specified and directed by EIC.

2

-

-

... More
S&F of MCCB in replacement 3 Pole from 25 Amps to 100 Amps fixed type 16 KA, 415 volts complete all as specified and directed including taking out old one all as specified and directed by EIC.

4

-

-

... More
S&F of MCCB in replacement 3 Pole from 125 Amps 16 KA, fixed type 415 volts complete all as specified and directed including taking out old one all as specified and directed by EIC.

4

-

-

... More
S&F of MCCB in replacement 4 Pole 160 amps 36 KA 415 volts adjustable type complete all as specified and directed including taking out old one all as specified and directed by EIC.

4

-

-

... More
S&F of MCCB in replacement 4 Pole 200 amps 36 KA 415 volts adjustable type complete all as specified and directed including taking out old one all as specified and directed by EIC.

5

-

-

... More
S&F of MCCB in replacement 4 Pole 250 amps 36 KA 415 volts adjustable type complete all as specified and directed including taking out old one all as specified and directed by EIC.

6

-

-

... More
S&F of MCCB in replacement 4 Pole 350 amps 36 KA 415 volts adjustable type complete all as specified and directed including taking out old one all as specified and directed by EIC.

5

-

-

... More
S&F of MCCB in replacement 4 Pole 400 amps 36 KA 415 volts adjustable type complete all as specified and directed including taking out old one all as specified and directed by EIC.

4

-

-

... More
Material and labour in replacement/repair for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (2009) connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt alround earth plate, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) 50mm thick cover reinforced with 8mm dia TMT bars @ 100mm c/c both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm bore GI medium grade earth lead protection pipe, complete all as specified and directed. Note :- Earth strip 32x6 mm and protection pipe 40 mm dia up to 7.5 mtr shall be included in quoted rate.

12

-

-

... More
S&F for GI earthing strip 32x6 mm with nut and bolts complete including taking down old one all as specified and directed by Engr-In Charge

40

-

-

... More
M&L for Preparation of old painted surfaces of steel tubular poles 9/11 Mtr long including cross arms protection pipe and painting one coat of aluminium paint e ground level to top of pole and cross arms and protection pipe paint including writing poles numbers in white letter on black ground complete all as specified and directed by Engr-in-Charge.

450

-

-

... More
S and F in repair loop in / loop out box of internal size 250 x 210 x 115mm made out of FRP (Hot moulded type) with weather proof canopy and locking screws alongwith 5/6 Amps MCB-01 No, 15 Amps rated 3 pole connector - 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector complete in the box, duly fixed to steel tubular pole using 25 x 3mm FI clamp with suitable gland and lugs for connecting cable including taking down old one complete all as specified and as directed.

30

-

-

... More
Taking down existing rusted/broken out MS cross arm, angle, clamps, nuts, bolts and washers and supply and fixing new MS Cross arms, bracings, supports, clamp and back plates fabricated for cable cover frame work, from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed.

1

-

-

... More
M&L in replacement of unserviceable ACSR jumper and ACSR Conductor with new jumpers of ACSR conductor and ACSR Conductor of suitable size as per site including binding properly on the existing OH line with clamp, nuts & bolts etc.complete all as specified and directed.

1

-

-

... More
supply and fixing in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size

50

-

-

... More
supply and fixing in replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade

70

-

-

... More
M&L for replacement of shackle type porcelain, vitreous white brown or insulator working under 1100 volts grade , pressure of height 75 mm & 90mm dia insulators, dia of bolt 12mm , section of straps 31 x 3mm, washers, nuts complete all as specified & directed.

55

-

-

... More
Supply and fixing in replacement of guard wire under LT Over head line Cradles, hexagonal/rectangular,fabricated with galvanised steel wire 3.15 or 4mm dia

1

-

-

... More
Trimming and cutting of tree branches(not more than 50 mm girth) coming across LT over head line clearing the line around 2m single/both sides and and disposal of branches from site exeeding 50m and not exceeding 250m from site complete all as directed by Engr-in-Charge. Note : - (i) Due care is to be given while trimming/cutting the tree branches that there should no damage to over head line conductor/pole. In case due to any negligence, damage is caused to be make good/renewal by the contractor from his own resources and nothing extra is admissible. (ii) All Safety to labourer must be adhered by the contractor during trimming and cutting of tree branches.

350

-

-

... More
Supply & Fixing in replacement of existing PCC/Steel pole with new steel tubular poles complete with cast iron base plate, final taper, plug, bolts, nuts & washers as specified type 410 SP-31 (9.0 mtr long) including re-fixing of removed accessoreis such as ACSR/AAC conductor, cables, street light fittings, clamps, nuts & bolts etc complete all as specified and directed by Engr-in-charge. Note :- Excavation, MS work and PCC work will be measured and paid separately.

4

-

-

... More
Taking down rusted anticlimbing device and providing anticlimbing device spikes type fabricated out of MS bars (round/square/flat) including nuts, bolts, washers and welding into halves made to shape to suit the cross section of steel/RCC poles complete all as specified and directed.

0.5

-

-

... More
M&L for removing all connections, bindings etc of ACSR/AAC conductor on existing LT poles & stretching of ACSR/AAC conductor upto required sag of any size and cross section of conductor and stretching of GI wire on existing pole including making necessary connection & binding with binding wire including cutting of tree branches from both sides upto the stress on each side complete all as specified and as directed by Engr-in-charge.

150

-

-

... More
Taking down U/S stay assy and M&L for stay assy comprising of MS stay plate of size 23cmx23cmx6mm thick, stay rod with nuts 215cm ling 20mm dia , MS/GI stay bow 40cm lingh with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm of suitable length, loop insulation size 65x90mm clearance of hole 16mm & other accessories including excavation earth work & PCC work complete all as per SSR Pt-1 plate No-1 complete all as specified and directed by Engr-in-charge.

4

-

-

... More
Supply and fixing for in replacement of LT 1100 volt Line rigid PVC spacers type 4 lines complete all as specified and directed by Engr-in-charge.

150

-

-

... More
All as per item No 64 above but 2 line.

100

-

-

... More
Supply and fixing in replacement Onload changeover switch AC-21(side handle) in sheet enclosure 415 Volt , 50 Hz four pole 400 Amp all as specified and directed by EIC.

2

-

-

... More
Supply and fixing in replacement Onload changeover switch AC-21(side handle) in sheet enclosure 415 Volt , 50 Hz four pole 200 Amp all as specified and directed by EIC.

2

-

-

... More
Supply and fixing in replacement Onload changeover switch AC-23 (side handle) in sheet enclosure 415 Volt , 50 Hz double pole 100 Amp all as specified and directed by EIC.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.