Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Dec 2024
Closing Date21 Jan 2025
Tender Amount₹ 48,78,000
Costs
EMD
₹ 97,560Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_690602_1Tender No
8137/E8 OF 2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Material and labour for sand/fine dust cushioning to under ground cable providing with a layer of 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge
NOTE :- Punning thickness of 18 cm will be measured for payment
75
-
-
... More
Supplying and laying precast, PCC LT cable cover, class LV, type flat , size 250mm x 150mm x 40mm complete for protection of underground cable all as specified and directed.
5500
-
-
... More
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
320
-
-
... More
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
155
-
-
... More
Dismantling of stone sett paving laid bedded and pointed in cement mortar of any description or thickness complete all as specified and directed.
18
-
-
... More
Demolition of cement concrete in ground floors and paving n exc 15 cm thickness ( below or above ground level) all as specified and directed.
3
-
-
... More
Material and labour for cement concrete 1:4:8 type D-2 (using 40 mm graded agg) 100 mm thick as in sub base for stone sett paving finished even and fair complete all as specified and directed.
12
-
-
... More
Material and labour for stone sett flooring with stone setts of size 200 to 150 mm long ,150 to 200 mm wide and 150 mm deep and sides dressed, bedded in and including 50 mm thick screed in cement mortar 1:3, joints 20 mm thick ; grouted in cement mortar 1:2 with an admixture of metallic floor harder 5% by weight of cement and struck flush complete all as specified and directed by Engr-in-Charge.
12
-
-
... More
Description all as item no 11.00 above but except stone complete all as specified and directed by Engr-in-Charge.
6
-
-
... More
Material and labour for flush pointing 20mm thick to stone sett paving any decription in cement mortar 1:3 with an admixture of metallic floor harder 5% by weight of cement all as specified an directed.
18
-
-
... More
Removal of debris (concrete, broken stone etc.) to out side defence land (distance exceeding 1.5 KM but n.exc 5KM from the site ) and depositing where directed.
3
-
-
... More
Supply, Laying , jointing and testing 10 Sqmm 2 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection including taking down existing cable complete all as specified and directed.
Make of cable :- Polycab/Finolex/Havells
190
-
-
... More
Supply, Laying, jointing and testing 10 Sqmm 4 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection including taking down existing cable complete all as specified and directed. Make of cable :- Polycab/Finolex/Havells
250
-
-
... More
Supply, Laying , jointing and testing 16 Sqmm 4 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection including taking down existing cable complete all as specified and directed.
Make of cable :- Polycab/Finolex/Havells
600
-
-
... More
Supply, Laying , jointing and testing 25 Sqmm 4 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection including taking down existing cable complete all as specified and directed.
Make of cable :- Polycab/Finolex/Havells
550
-
-
... More
Supply, Laying , jointing and testing 50 Sqmm 3.5 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection including taking down existing cable complete all as specified and directed. Make of cable :- Polycab/Finolex/Havells
100
-
-
... More
Supply, Laying , jointing and testing 70 Sqmm 3.5 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection including taking down existing cable complete all as specified and directed.
Make of cable :- Polycab/Finolex/Havells
125
-
-
... More
Supply, Laying , jointing and testing 95 Sqmm 3.5 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection including taking down existing cable complete all as specified and directed.
Make of cable :- Polycab/Finolex/Havells
100
-
-
... More
Supply, Laying , jointing and testing 120 Sqmm 3.5 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection including taking down existing cable complete all as specified and directed.
Make of cable :- Polycab/Finolex/Havells
450
-
-
... More
Supply, Laying , jointing and testing 150 Sqmm 3.5 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection including taking down existing cable complete all as specified and directed. Make of cable :- Polycab/Finolex/Havells
450
-
-
... More
Supply, Laying , jointing and testing 185 Sqmm 3.5 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection including taking down existing cable complete all as specified and directed.
Make of cable :- Polycab/Finolex/Havells
90
-
-
... More
Supply, Laying , jointing and testing 240 Sqmm 3.5 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection including taking down existing cable complete all as specified and directed.
Make of cable :- Polycab/Finolex/Havells
60
-
-
... More
Supply, Laying , jointing and testing 300 Sqmm 3.5 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection including taking down existing cable complete all as specified and directed. Make of cable :- Polycab/Finolex/Havells
60
-
-
... More
Supply, Laying , jointing and testing 400 Sqmm 3.5 core LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls including cable gland of suitable sizes and aluminium lugs for connection including taking down existing cable complete all as specified and directed. Make of cable :- Polycab/Finolex/Havells
100
-
-
... More
(Item No.27 Contd...)
Note for Item No 15 to 27:- (i) During earth work for laying of cable, any damage to the existing services shall be made serviceable without any extra cost within 24 hrs. (ii) Contractor should visit the site before quoting the rate for understanding the scope of work. (iii) The cost of saddling of cables on walls/roof is included in the above qouted rates.
-
-
-
... More
Supply and fix tubing 'light grade' galvanised iron 100 mm with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed.
6
-
-
... More
Supply and fix tubing 'light grade' galvanised iron 80 mm with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed.
6
-
-
... More
Supply and fix tubing 'light grade' galvanised iron 50 mm with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed.
6
-
-
... More
Supply and fix tubing 'light grade' galvanised iron 40 mm with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed.
6
-
-
... More
Material and labour for cutting through existing bituminous road /PCC/floor along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finishes complete all as specified and directed. NOTE :- Contractor should visit the site before quoting the rate & GI Pipe will be measured and paid seperately in respective item.
24
-
-
... More
Material and labour in replacement of u/s MCCB 415V, 3 phase 50 HZ FP 63 to 100 Amps breaking capacity 16KA complete all as specified and directed. MAKE :- Legrand or equivalent in Schneider/Havells/ C&S/ L&T.
4
-
-
... More
Material and labour in replacement of u/s MCCB 415V, 3 phase 50 HZ FP 125 Amps breaking capacity 16 KA. Switch/rotery type and as per existing all as specified and directed by Engr-in-Charge. MAKE :- Legrand or equivalent in Schneider/Havells/ C&S/ L&T.
6
-
-
... More
Material and labour in replacement of u/s MCCB 415V, 3 phase 50 HZ FP 160 Amps breaking capacity 16 KA. Switch/rotery type and as per existing all as specified and directed by Engr-in-Charge. MAKE :- Legrand or equivalent in Schneider/Havells/ C&S/ L&T.
9
-
-
... More
Material and labour in replacement of u/s MCCB 415V, 3 phase 50 HZ FP 200 Amps breaking capacity 36 KA. Switch/rotery type and as per existing all as specified and directed by Engr-in-Charge. MAKE :- Legrand or equivalent in Schneider/Havells/ C&S/ L&T.
3
-
-
... More
Material and labour in replacement of u/s MCCB 415V, 3 phase 50 HZ FP 250 Amps breaking capacity 36 KA Switch/rotery type and as per existing all as specified and directed by Engr-in-Charge.
MAKE :- Legrand or equivalent in Schneider/Havells/ C&S/ L&T.
3
-
-
... More
Material and labour in replacement of u/s MCCB 415V, 3 phase 50 HZ FP 400 Amps breaking capacity 36 KA Switch/rotery type and as per existing all as specified and directed by Engr-in-Charge. MAKE :- Legrand or equivalent in Schneider/Havells/ C&S/ L&T.
2
-
-
... More
Material and labour in replacement of u/s MCCB 415V, 3 phase 50 HZ FP 630 Amps breaking capacity 36 Switch/rotery type and as per existing all as specified and directed by Engr-in-Charge. MAKE :- Legrand or equivalent in Schneider/Havells/ C&S/ L&T. Note Sl item No 34 to 40 :- Rates include for necessary altretion for replacement of MCCB in existing panel and necessary connection of incoming & out going cable as per existing maner and including lugs, peruls and connected items.
2
-
-
... More
Material and labour for disconnecting LT XLPE cable of any size from LT Panel or any location as directed for finding fault and Material and labour for defect rectification of underground cable laid in trenches or any location by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. all as directed. NOTE :- (i) The fault locating equipments will be brought to site within the 12 hours of instruction from Engr-in-Charge.
(ii) Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and has to be rectified within 12 hours after notification, failing which Rs 500/- per day per complaint will be recovered from the dues to the contractor.
(iii) Rates include necessary earth work .
20
-
-
... More
Material and labour for straight through (Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm including dismantling the old burnt cable joint termination complete all as specified and directed by Engr-in-Charge .
4
-
-
... More
Material and labour for straight through (Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 150 Sqmm including dismantling the old burnt cable joint termination all as specified and directed by Engr-in-Charge .
4
-
-
... More
Material and labour for straight through (Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 to 300 Sqmm including dismantling the old burnt cable joint termination all as specified and directed by Engr-in-Charge .
3
-
-
... More
Supply, installation, commissioning and testing of outdoor type Outgoing Bus Bar LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar, of capacity 250 Amps fabricated in factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 . The panel shall be made out of 3.00mm thick CRCA mild steel sheet , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work and the following :- (a) Incommer:- MCCB 4 pole 250A, 36kA, thermal & magnetic release - 01 Nos Make of MCCB :- Legrand or ABB/ Schneider/Havells
4
-
-
... More
Supply, installation, commissioning and testing of outdoor type Outgoing Bus Bar LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar, of capacity 100 Amps fabricated in factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 . The panel shall be made out of 3.00mm thick CRCA mild steel sheet , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work and the following :- (a) Incommer:- MCCB 4 pole 100A, 16kA, thermal & magnetic release - 01 Nos Make of MCCB :- Legrand or ABB/ Schneider/Havells
4
-
-
... More
Material and labour for earthing complete with hot dip galvanized steel pipe in pipe electrode, outer pipe 88mm dia medium grade and inner pipe 55 mm dia including testing, 3 mtr long and having 50x6 mm terminal on inner pipe to connect earthing strip with 14 mm holes for nut bolts, buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and 3.3 mtr deep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with galvanized steel earthing lead of 32x6 mm strip with minimum two Nos of GI nut bolits and connected to test point from earthing pit. The electrode pipes should be filled with 2x 25 kg bags of carbon based earthing compound. The resistance of the compound should be less than 0.1 Ohms . The compound should be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities with ph value between7-9. Connected to the earthing test point, Fiber reinforced plastic pit not less than 300x300 mm with pit cover, including necessary returning filling & removal of extra soil , to achieved earth resistance value less than 5 Ohms including testing complete all as specified and directed. Make U-Protect or equivalent NOTE :- IF the desired result not obtained after testing the contractor should do re-earthing without any extra cost.
15
-
-
... More
Material and labour for connecting galvanised iron ( GI ) strip 32 X 6 mm, in replacement to the existing earthing strip to eqpts complete all as specified and directed.
150
-
-
... More
Supply and errect in true vertical position steel tubular swaged poles complete with MS base plate of 6mm of size 300mmX300mm finial taper plug, pole cap, bolts, nuts and washers screws, pole made out of ERW MS tubing as per IS-1161 and pole shall be as per IS-2713 Part II type 410 SP-31 (9.00 Mtrs Long) complete including one coat of red oxide zinc chrome primer and two coats of Aluminium paint for exposed surfaces and two coats of black bitumenous paint for portion embedded in concrete complete all as specified and as directed NOTE :- Excavation and earth work , PCC in foundation /plinth block/coping shall be measured and paid separately
12
-
-
... More
Material and labour for dismantling electric pole any type any size and removing from site all as specified and as directed.
12
-
-
... More
Material and labour for Cement concrete in foundation filling and mass concrete 1 : 4 : 8 type D2 complete all as directed by Engineer-in-charge.
8
-
-
... More
Material and labour for PCC 1:3:6 type C-1 with 20mm agregate in copping including necessery form work all as directed by Engr-in-Charge
3
-
-
... More
Dismantling of ACSR conductor HT/LT on any type of pole, cradle guard and earthing wire complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
Supply, stringing, streching and binding with insulator, ACSR conductor (Weasel /ferret/Mink) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc all as specified & directed.
2
-
-
... More
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 1 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as directed.
NOTE :-
(a). The trees branches etc will be removed from site and stack as directed and will not be carried away by the contractor as the wood belongs to CEO / DEO.
(b). Prooning of all tree branches in per Span (not less than 30 Mtr) in HT/ LT OH Line shall be measured as one Job. (c). Contractor will employ sufficient labour to complete the job with in time as directed. (d). Contractor will be responsible for any type of mis-happening / accident while prooning the trees. (e). Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply. (f). The contractor will provide proper tools and safety devices to his staff for prooning of trees.
50
-
-
... More
Material and labour in replacement Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding , bending cold or hot, drilling holes for bolts, in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed.
1
-
-
... More
Supply and fix pin type porcelain , vitreous white, brown or green insulator including galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia wahsers, bolts etc as working pressure 1100 volts complete all as specified and directed.
10
-
-
... More
Supply and fix shackle type porcelain , vitreous white, brown or green insulator including galvanised mild steel straps, wahsers, insulator bolts, wahsers and nuts, as working pressure 1100 volts height 100 mm maximum dia 115 mm section of straps in 31 x 5 mm dia of bolts 14 mm complete all as specified and directed.
10
-
-
... More
Removing of old main switch after disconecting the incoming and out going cables and supply and fix MCCB thermal magnetic release four pole 25 KA 63 Amps Make Legrand Cat No 420053 /L&T /ABB with one way metal enclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nutbolt etc including making good the disturbed suface of wall including material complete all as specified and as directed.
10
-
-
... More
Removing of old main switch after disconecting the incoming and out going cables and supply and fix MCCB thermal magnetic release four pole 25 KA 100 Amps Make Legrand Cat No 420055 /L&T /ABB with one way metal enclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nutbolt etc including making good the disturbed suface of wall including material complete all as specified and as directed.
4
-
-
... More
Removing of old main switch after disconecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 25 KA 160 Amps Make Legrand Cat No 420057 /L&T /ABB with one way metal enclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complete all as specified and as directed.
2
-
-
... More
Removing of old main switch after disconecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 25 KA 200 Amps Make Legrand Cat No 420218 /L&T /ABB with one way metal enclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complete all as specified and as directed.
3
-
-
... More
Removing of old main switch after disconecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 35 KA 250 Amps Make Legrand Cat No 420249 /L&T /ABB with one way metal enclosure LegrandCat No 5078 01 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complete all as specified and as directed.
2
-
-
... More
Removing of old main switch after disconecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 35 KA 400 Amps Make Legrand Cat No 422007 /L&T /ABB with one way metal enclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complate all as specified and as directed.
1
-
-
... More
Removing of old main switch after disconecting the incoming and out going cables, supply and fix MCCB thermal magnetic release four pole 35 KA 630 Amps Make Legrand Cat No 422009 /L&T /ABB with one way metal enclosure Legrand Cat No 5078 01 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complete all as specified and as directed.
1
-
-
... More
Removing of old main switch after disconecting the incoming and out going cables, supply and fix Industrial plug and socket board TP 32 Amps including plug top and MCB "C" curve 10 KA 32 Amps Make Legrand Cat No 5078 18 and 4086 58 /L&T /ABB and making conections of cables with suitable size nuts, bolt etc including making good the disturbed suface of wall complete all as specified and as directed.
3
-
-
... More
Removing of old main switch after disconecting the incoming and out going cables, supply and fix one way metal enclosure all as per Legrand Cat No 5077 93 /L&T/ABB and MCB "C" curve TPN 10 KA 32Amps Legrand Cat No 4086 80 /L&T/ABB and making conections of cables with suitable size nuts, bolt etc. including making good the disturbed suface of wall complete all as specified and as directed.
10
-
-
... More
Supply, fixing, connecting and testing in replacement of industrial earth plug & socket with sheet metal enclosure of IP 44 protection rating, electric driven, single phase including MCB 'C' series SP 20 Amps and supplied with neutral link complete all as specified and as directed.
3
-
-
... More
Supply, fixing, connecting and testing in replacement industrial earth Plug & socket with sheet metal enclosure of IP 44 protection rating, electric driven three phase including MCB 'C' series TP 20 Amps and supplied with neutral link complete all as specified and as directed.
4
-
-
... More
Material and labour for preparation of old painted surface of LT Steel tubular pole of any length by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with double coat of apex exterior, synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos) & rest of the height of the pole is in silver colour aluminium paint, including bracing support on poles and writing of identification Nos with proper stencil cut etc as per directions by Engineer-in-Charge.
100
-
-
... More
Material and labour for preparation of old painted surface of F/P box/LT Panel by removing all dirt, dust, etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour over a coat of primer including writing of identification with proper stencil cut etc as per directions by Engineer-in-Charge
20
-
-
... More
Material and labour for disconnecting old worn out control wiring connections incl cable lugs of LT panel board , taking down existing bus bars system from LT panel board of all size cleaning with CTC, removing old insulation and providing new heat shrink insulating sleeves as per the site requirements, connecting and fixing in the same panel with new nuts, bolts, washers of suitable size complete all as specified and directed by Engr-in-Chage.
20
-
-
... More
Disconnecting and taking down old distribution Box with MCB/fuse grip TPN/SPN DB 2 Way to 12 Way old type DB including taking out all cable connections of any description and in any position and making good the disturbed surface of walls, to match with the existing surfaces complete all as specified and directed by Engineer in charge.
6
-
-
... More
Supply and fix connecting & testing of VTPN DB of 12 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified and as directed. MAKE :- Legrand Cat.No. 5077 48 or equivalent in Schneider/L&T. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule.
2
-
-
... More
Supply and fix connecting & testing of VTPN DB of 8 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed. MAKE :- Legrand Cat.No. 5077 47 or equivalent in Schneider / L&T. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule.
2
-
-
... More
Supply and fix connecting & testing of VTPN DB of 4 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed. MAKE :- Legrand Cat.No. 5077 45 or equivalent in Schneider/ L&T. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule.
2
-
-
... More
Disconnecting and taking out existing SMC of any size and in any position on pole and Supply & fix in repair sheet moulding compound junction (SMC) suitable for terminating 2 Nos 4 x 6/10/16 Sqmm UG cable including S&F of one in Nos MCB SP 6-32A including cable glandes- 2 Nos, and two way connector 1 No, including dismantling old one complete all as specified and as directed. MAKE :- Sintex/National
20
-
-
... More
Supply, installation, commissioning and testing of indoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar of 300 Amps capacity, pre-wired and, fabricated in CPRI Approved panel factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The panel shall be made out of 2.00mm thick CRCA mild steel sheet including suitable stainless steel nuts, bolts & washers for incoming/Outgoing feeder etc duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. The feeder pillar shall be comprising of the followings:- Incommer :- MCCB 4 pole 200A, 25kA, thermal & magnetic release - 01 Nos Outgoing :-
(a) MCCB 3 pole 63A, 16kA, thermal & magnetic release - 02 Nos
(b) MCCB 3 pole 40A, 16kA, thermal & magnetic release - 06 Nos
(c) Digital Multifunction meter & indicator set (RYB) - 01 Set
1
-
-
... More
Supply, installation, commissioning and testing of indoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar of 500 Amps capacity, pre-wired and, fabricated in CPRI Approved panel factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS:13947. The panel shall be made out of 2.00mm thick CRCA mild steel sheet including suitable stainless steel nuts, bolts & washers for incoming/Outgoing feeder etc. duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. The feeder pillar shall be comprising of the followings:- Incommer :- MCCB 4 pole 320A, 36kA, thermal & magnetic release - 01 Nos.
Outgoing :- (a) MCCB 3 pole 100A, 16kA, thermal & magnetic release - 01 Nos.
(b) MCCB 3 pole 63A, 16kA, thermal & magnetic release - 04 Nos.
(c) MCCB 3 pole 40A, 16kA, thermal & magnetic release - 04 Nos.
(d) MCCB 3 pole 16A, 16kA, thermal & magnetic release - 04 Nos.
(e) Digital Multifunction meter & indicator set (RYB) - 01 Set
1
-
-
... More
Supply, installation, commissioning and testing of outdoor type LT panel box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bar of 600 Amps capacity, pre-wired and, fabricated in CPRI Approved panel factory having modern fabrication duly powder coated painting, dust and vermin proof and degree of protection not less than IP-65 and general construction conforming to IS:13947. The panel shall be made out of 3.15mm thick CRCA mild steel sheet including suitable stainless steel nuts, bolts & washers for incoming/Outgoing feeder etc. duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and suitable angle iron mounting base frame at bottom min 0.6 Mtr above ground level incl PCC work. The feeder pillar shall be comprising of the followings:- Incommer :- MCCB 4 pole 400A, 36kA, thermal & magnetic release - 01 Nos.
Outgoing :- (a) MCCB 4 pole 250A, 25kA, thermal & magnetic release - 02 Nos.
(b) MCCB 4 pole 100A, 16kA, thermal & magnetic release - 01 Nos.
(c) MCCB 4 pole 63A, 16kA, thermal & magnetic release - 04 Nos.
(d) Digital Multifunction meter & indicator set (RYB) - 01 Set
1
-
-
... More
Supplying & fixing in replacement MCB 6 to 32 Amps, single pole and neutral, "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and directed. MAKE :- Legrand/ABB/L&T/ Havells/Schneider.
6
-
-
... More
Supplying & fixing in replacement MCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, complete all as specified and directed. MAKE :- Legrand/ABB/L&T/ Havells/Schneider.
30
-
-
... More
Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground All as specified and directed.
250
-
-
... More
Copper strip 20 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground all as specified and directed by Engr-in-Charge
50
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past