Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date7 Nov 2024
Closing Soon31 Dec 2024
Tender Amount₹ 90,94,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SER. ITEM No. 2.00 ABOVE (CONTD....) (e) Explosive vent, Thermometer pocket on tank cover, oil level gauge, Oil drain filter valve, Jacking / Lifting lugs, Marshalling 55, with oil filling hole with cap/plug with connection plate complete, Air release valve plug and four no. plain solid cast steel detachable rollers. (f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree Celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 50x6mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate. (j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral. (k) First fill of new and unused transformer oil, IS-335 of 1986 marked, filtered and tested up to 50 KV dielectric strength at 2.5 mm air gap between testing electrodes, specific resistance at 27 Degree Celsius Ohm-ohm 500 x 10 the power12, water content 50 PPM, Dielectric dissipation factor (tan Delta at 90 degree Celsius) 0.005, Neutralisation value mg of KOH/gm of oil 0.03, Inter facial tension N/M at 27 Degree Celsius - 0.04, flash point 140 Degree Celsius with sludge 0.1% by weight. (l) Detachable Rollers of adequate load capacity and no. of channels, embedded in floor, for movement of transformer. (m) Top and Bottom Filter cum drain Valves with Dummy. (n) 6" Oil temperature indicator and winding temperature indicator with alarm and Trip contacts. (o) Radiators shall be of Detachable type with proper butter fly valves. (p) Double Float Buchholz Relay with alarm and trip Contacts.

-

-

-

... More
All as per Ser. Item No. 2.00 above but for transformer of capacity 160 KVA complete all as specified and as directed.

2

-

-

... More
All as per Ser. Item No. 2.00 above but for transformer of capacity 250 KVA complete all as specified and as directed.

1

-

-

... More
All as per Ser. Item No. 2.00 above but for transformer of capacity 400 KVA complete all as specified and as directed.

1

-

-

... More
All as per Ser. Item No. 2.00 above but for transformer of capacity 800 KVA complete all as specified and as directed.

1

-

-

... More
NOTES FOR SER. ITEM NO. 2.00 TO 6.00 ABOVE.... (a) The OEM of the transformers should have in house LAB Certificate for Accreditation from National Accreditation Board for Testing and Calibration laboratories. (b) Manufacturer /OEM must have type test / short circuit reports for each & every rating from CPRI / ERDA (matching all the major parameters including the Loss Figure) shall not be older than 5 years. (c) Core shall be procured from one of these manufacturers – Posco/Nippon/NLMK/AK Steels or NOVEX Trader CRGO and CRGO core grade used should be M-OH / ZDKH / TCH only. Procurement, Mill's Test Certificate / Invoice from supplier /Bill of landing Bill of entry certificate by CUSTOMS shall be provided. The OEM Should have in house core cutting / slitting Machine. Burr level should be less than 10 Microns. (d) CPRI Short circuit test report for exactly similar transformer (matching all major electrical parameters including Loss Figure) shall not be older than 5 years to be furnished). (e) OEM should be BIS and BEE certified for all the ratings of the transformer that are to be submitted. (f) Rate quoted includes the cost of making and Testing of control wiring connection at the Transformer and RMU/VCB for the Temperature alarm/Trip, Gas alarm/Trip. The Control cable shall be measured and paid separately under relevant item. (g) Expenses / cost for FAT and necessary Travel / freight / conveyance / stay expenses for inspecting/ testing officers as nominated by the Accepting Officer for FAT shall be included in the rate quoted. (h) Tender/ contractor shall submit all the necessary certificates/ material Invoice of core as mentioned in above note (a) to (e) along with Guaranteed Technical Particulars (GTP) from the OEM of transformer for make Approval by the Accepting Officer before placing the Order.

-

-

-

... More
Supply, laying and testing of HT cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11000 Volts grade cross sectional area 3 Core x 95 Sqmm ISI Marked complete all as specified and as directed. (Note : Cost of provision of suitable double crimpped lugs and glands shall deemed to be included in quoted rate.)

100

-

-

... More
M&L for XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (heavy duty) 11000 Volts grade (earthed) with aluminium conductor 3 core 120 sqmm ISI marked laid in trenches, duct, through pipe, under floor, on pole including jointing and testing complete all as specified and as directed.

110

-

-

... More
Supply, laying and testing of cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 400 Sq mm. complete all as specified and as directed. Note : Cost of provision of suitable double crimpped lugs and glands shall deemed to be included in quoted rates.

100

-

-

... More
Supply and fix cable End jointing kit for 11 KV (E) grade cable for indoor termination jointing and testing of heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cables of size 120 to 185 sqmm complete all as specified and as directed.

1

-

-

... More
Supply and fix cable End jointing kit for 11 KV (E) grade cable for outdoor termination jointing and testing of heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cables of size 120 to 185 sqmm complete all as specified and as directed.

5

-

-

... More
Supply and fix HT Cable jointing kit for 11 KV (Earthed) grade cable for outdoor End termination Heat shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and as directed.

8

-

-

... More
S & Fix End Cable jointing kit for 11 KV (Earthed) grade cable heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 300sqmm XLPE armoured aluminium conductor cable (11KV, 300 sqmm Touch proof) complete all as specified and as directed.

4

-

-

... More
Supply and lay pipe galvanized, “Light grade”, including fittings 100 mm dia for cable protection with clamps nut bolts to fixby clamp/ nuts - bolts etc. against existing MS channel of HT structure all as specified and as directed.

18

-

-

... More
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.

60.75

-

-

... More
Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.

58.45

-

-

... More
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level not exc 50m above the starting point complete all as specified and as directed.

2.3

-

-

... More
Supply and laying 77 mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.

210

-

-

... More
Material and labour for 100mm thick PCC (1:2:4) type B2 (using 40mm graded broken stone aggregate) as in sub base complete all as specified and as directed.

11

-

-

... More
Material and labour for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed.

13

-

-

... More
Material and labour for rendering 15mm thick in cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement all as specified and as directed.

36

-

-

... More
Material and labour for prepration of new plastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified and as directed.

36

-

-

... More
Material and labour 100mm thick PCC (1:2:4) type B1 (Using 20mm graded stone aggregate) as in floor top finished even and smooth without using extra cement complete all as specified and as directed.

9

-

-

... More
M&L for Glass dividing strips, width of strip 38mm, 3 mm thick, inserted in position, confirm to design complete all as specified and as directed.

12

-

-

... More
Supply, install, testing and commissioning of 11KV 630 Amps 21KA for 3 Sec. SF6 insulated, One side extensible, outdoor duty Manual FOUR (4) way ( 02 Nos Incomer and 02 Nos outgoing) Ring main unit in combination of 2 nos LOAD BREAK SWITCH modules and 2 nos. VCB modules consisting of copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer fixed, with series trip, self-powered microprocessor based numerical over current relay (IDMTL + Inst.) in each VCB feeder. Suitable CT for Protection to be provided with each VCB Feeder. The HV switchgear and control gear should be confirming to IEC-62271-1, 100, 200. The RMU should be internal arc tested for 21 KA for 1Second with IAC-AFLR classification for gas tank & cable box. The complete RMU front along cable chamber to be covered by an seperate outdoor door to have ingress protection of minimum IP65. The RMU design should support site replaceable HT cable bushing and VI of VCB should be RMU Manufacturer’s own make. Each feeder of should have voltage presence indicator. All the type test certificated as per IEC from Third party lab to be submitted.

1

-

-

... More
SER. ITEM No. 26.00 CONTD... RMU Should have followings: - 1 No. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 100-50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB. - VCB should confirm operating sequence O-0.3 Sec-CO-3min-CO and 10000 mechanical operation. - 1 No. Manometer for each tank - 1 No. Voltage passage indicator for each feeder. - 1 No. Fault passage indicator for each RMU. - Right angle boots for all the feeder Modules (NOTE : Design of RMU to be approved by GE before supply of item by the Contractor.)

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.