Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date15 Jun 2024
Closing Date13 Jul 2024
Tender Amount₹ 5,57,00,000
Costs
EMD
₹ 6,03,500Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_660248_1Bid Award Id
ViewTender No
8870/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling fencing wire mesh, any type complete all as specified and directed.
1100
-
-
Excavation over areas n exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed.
4270
-
-
Excavation over areas exc 1.5m in depth and not exc 3.0m in depth in hard/dense soil and getting out, complete all as specified and directed.
7.2
-
-
Excavation in trenches,n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc and getting out in hard /dense soil complete all as specified and directed.
979
-
-
Returning,filling in,including spreading, levelling,watering and well ramming in layers n.exc 25cm thick in soft/loose/hard dense soil.
1172.4
-
-
M & L for moorum/red bajri filling in floors or paving laid in layers n exc 15 cm thick, spread, levelled, and rammend including watering complete all as specifed and directed
1000
-
-
Forming embankments inlcuding rasing (or lowering) earth, spreading in layers n. exc. 30 cm thick, watering, ramming / rolling and finishing to required size, shape, etc. n.exc 15cm high base complete all as specified and directed.
3850
-
-
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
393
-
-
Removing excavated soil to a distance exc 250m and not exc 500m deposited where directed at a level n.exc 1.50m above the starting point complete all as specified and directed.
200
-
-
Removing of debris, excavated material to outside MoD land n. exc 1.50 KM distance complete all as specified and directed
352
-
-
Removing excavated material to a distance exc 1.50 Km but n.exc.5 Km and depositing outside MD land complete all as specified and directed.
450
-
-
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
975
-
-
M & L for rolling and consolidating formation surfaces in cutting with power roller exceeding 8 tonne and not exceeding 12 tonne complete all as specified and directed.
450
-
-
M & L for soling (or sub base) with broken boulders or quarried stone, interstices filled, surface formed and rolled and consolidated to required gradient and camber 150mm complete all as specified and directed.
450
-
-
M & L Cement concrete 1:4:8 type D2 (40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
450
-
-
M & L for 20 cm thick cement concrete work in pavement/hardstanding of flexural strength 40kg/per square centimetre in field using 400 kg of cement per cubic metre complete all as specified and directed.
900
-
-
M & L for forming construction joints 300mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as specified and directed.
220
-
-
M & L for Forming contraction (Dummy) joints 65mm deep x 10mm wide , filled with sealing compound Grade 'A' complete all as specified and directed.
220
-
-
M&L for cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in surface channels and drawing complete all as specified & directed.
25
-
-
M & L Pre-cast cement concrete block masonry with solid blocks Type C1 1:3:6, exc. 10 cm in width and setting in Cement (1:4) mortar complete all as specified and directed.
60
-
-
M&L for pre-cast cement concrete block masonary with solid blocks(1:2:4) type B1 (20mm graded agg), exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
581
-
-
M&L for Pre cast cement concrete block masonry with solid block of grade (C-5) having block density not less than 1800 Kg/cum, exc, 10cm in width and setting in CM 1: 6, complete all as specified and directed.
180
-
-
M & L for cement concrete 1:3:6 type C-1, using 20mm grade stone aggregate as in coping of stone masonry wall, bed blocks and the like including weathering slightly rounded or chamfered and throating as directed including necessary formwork complete all as specified and directed.
5
-
-
M&L rendering 15mm thick on fair faces of stone masonry or concrete surface in CM 1:4 is to be finished even and smooth(without using extra lime or cement) complete all as specified and directed.
300
-
-
M&L RCC class NP2 hume pipes laid and joined complete with collars of 300mm dia complete all as specified and directed.
30
-
-
M&L for 300 mm thick Concrete bed to drain pipes in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested for 300 mm bore pipe complete all as specified and as directed
30
-
-
M&L RCC class NP2 hume pipes laid and joined complete with collars of 450mm dia complete all as specified and as directed.
30
-
-
M&L for 450 mm thick Concrete bed to drain pipes in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested for 450 mm bore pipe complete all as specified and as directed
30
-
-
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed.
250
-
-
Add or deduct for each 24 mm girth or part thereof over or under 30 cm -ditto-
250
-
-
M&L for PCC 1:3:6 type C2 (using 40mm graded aggregate) as in foundations,filling and mass concrete complete all as specified and directed.
101.2
-
-
M&L for reinforced cement concrete (Design mix) complete in M-30 (20mm graded aggregates) for foundation including raffs, footins, plinth beams, bases for columns etc complete all as specified and directed.
184
-
-
M&L for reinforced cement concrete (Design mix) in M-30 (using 20mm graded aggregate) in columns/pillars etc. complete all as specified and directed.
151
-
-
M&L for reinforced cement concrete Type B1 1:2:4 (20mm graded aggregate) for beams, lintels over 1.5m span complete all as specified and directed.
44
-
-
M&L for reinforced cement concrete Type B1 1:2:4 (20mm graded aggregate) in lintels upto 1.5m clear span, cills, steps, copings, plinth courses complete all as specified and directed.
2.05
-
-
M & L for formwork to sides of concrete foundations and plinth beams and similar work vertical or to batter for fair finished flat concrete surface complete all as specified and directed.
425
-
-
M&L formwork to sides of pillars, posts, struts, piers, columns and stanchions for square, rectangular fair finished concrete surface complete all as specified and directed.
2030
-
-
M&L formwork to edges of conceret break in floors,window cills, railling, opening in concrete wall ,floor and roof not exc. 20cm wide and side of RCC bands in walls, horizontal or sloping and similar work exc10cm and n exc 20cm wide fair finished surfaces. and complete all as specified and directed
76
-
-
M&L formwork to side and soffits of floor or roof beams and lintels, cantilevers,overhanging etc.fair finished flat surfaces of concrete complete all as specified and directed.
1210
-
-
M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 10 mm dia & over, including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
37587
-
-
All as per Item No 38 but 5mm dia and over upto including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
12803
-
-
M&L for rendering 15mm thick on fair faces of bricks or concrete surface work in CM 1:4, finished fair and even inculiding with integral water proofing compound 3% for by weight of cement including necessary scaffolding complete all as specified and directed. (NOTE :- WPC shall be measured and paid separately) .
7084
-
-
Supply only integral Water Proofing compound
136
-
-
M&L for preparing new plastered surface of walls, and applying two coats of cement base paint over a coat of chalk whiting complete all as specified and directed
7834
-
-
S&F mild steel Framed work such as grills, gratings etc, with ends of bars shouldered or rebated or forged into spikes, framed guard bars, barred iron doors, railings, framework of water tanks and similar work conforming to Fe -290 Grade -E-165, complete all as specified and directed.
857
-
-
M & L for broken glass coping on top of walls in cement morter 1:3 complete all as specified and directed.
219
-
-
S & F Rolled Mild Steel Framed work as in doors or Gates of angle or other section confirming to Fe 410 - S, with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering and hanging and fixing complete all as specified and directed.
100
-
-
M & L for mild steel works (Fe-290 Grade E-165) as in posts and struts etc in fencing of angle or other sections, including cuttings tops to shape as directed, drilling holes, notching for wire etc, complete all as specified and directed.
13100
-
-
M&L two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface complete all as specified and directed.
1000
-
-
S&F galvanised 2 strand, steel barbed wire 2.24mm dia bars 75mm spacing fencing incuding dismantled wire to be coiled neatly as directed by EIC.
80
-
-
S & F Mild steel screw bolts (machine made) 10 mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm and n exc 10 cm long complete all as specified and directed.
70
-
-
S & F for pre painted Galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50 mm thick of any colour as approved, having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed.
660
-
-
S & F barbed razor type concertina coil DG hot galvanised spring for site wire manufactured by M/s Special steel Ltd or M/s Super Fence or Global Engrs as approved by GE, 1.45 to 1.50 Kg/metre and dia of coil when stretched 610 mm complete all as specified and directed..
1100
-
-
Fixing only Mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
6000
-
-
Dismantling plain or corrugated asbestoes sheeting, any guage, thickness complete all as specified and directed.
2000
-
-
Fixing only for 6mm thick corrugated asbestos sheet cladding to wall fixed with self tapping screws complete all as specified and directed.
2000
-
-
S & F for 6mm thick corrugated asbestos sheet ccladding to wall fixed with self tapping screws as specified and directed.
200
-
-
Grubbing up tree trunk including cutting of trunk portion ,digging out roots and levelling the ground, girth of tree exceeding 100cm and not exceeding 150cm removal of debris out side the MD land complete all as specified and directed.
20
-
-
M&L hardcore of gauge n.exc 63mm,deposited,spread and levelled in layers n.exc 15 cm thickness with broken stone or boulders, watered and rammed to a true surface complete all as specified and directed.
9
-
-
M&L for reinforced cement concrete (design mix) RMC M-30 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed.
28.8
-
-
M&L for reinforced cement concrete (design mix) RMC M-30 (using 20mm graded stone aggregate) for walls, retaining walls, basement walls and the like, any thickness, above top of footings, including attached pillasters and buttresses, complete all as specified and directed.
37.2
-
-
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished flat surfaces of concrete, complete all as specified and directed.
24
-
-
M&L Formwork to faces of walls, retaining wall, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses etc, vertical or to batter, for fair finished flat furfaces of the concrete, complete all as specified and directed.
186
-
-
M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions for square, rectangular or polygonal fair finished surfaces of the concrete, complete all as specified and directed.
15.2
-
-
M&L for rendering 15 mm thick on the wall surfaces of the concrete in CM 1:4 and finishing the surfaces even and smooth without using extra cement, complete all as specified and directed.
750
-
-
S&F 110mm outer dia, HDPE pipes (PE-63 grade), Class 3, 06 Kgf / Sqcm, in any length, laid through weep holes in the masonry wall, complete all as specified and directed.
50
-
-
M&L for coarse sand filling as in invert filter etc (at back of walls) laid in layers not exc 15cm thick, spread, levelled and consolidation including watering, complete all as specified and directed.
6
-
-
M&L for hand packing (any thickness) with boulders of gauge 60mm to 40mm as in invert filters etc (at back of walls) and raising (or lowering) to the required level, complete all as specified and directed.
5
-
-
M&L for hand packing (any thickness) with boulders of gauge 20mm to 12.5mm as in invert filters etc (at back of walls) and raising (or lowering) to the required level, complete all as specified and directed.
10
-
-
Taking out old unserviceable underground cable XLPE insulated, PVC sheathed armoured heavy duty aluminium conductor LT 1100 Volts grade of any size fixed on pole, wall and laid in trenches etc after disconnecting complete all as specified and directed.
Note - Excavation and earth work will be mesured and paid seprately.
2450
-
-
Dismantling of old UNSV PCC poles 9 mtr long including Street Light fittings including necessary disconnecting cables and removing unserviceable pole from site complete all as specified and directed.
30
-
-
M & L for sand cushioning by spreading in trenches crushed sand by gently punning down manually as in cable protection complete all as specified and as directed by Engineer -in-charge.
292.5
-
-
Supply and laying un-reinforced precast concrete cable cover class LV ISI marked,type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches,complete all as specified and directed.
24067
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core including cable lugs of suitable size, complete all as specified and directed.
1100
-
-
-ditto- all as per above item No. 77 but of size 10 sq mm 4 core complete all as specified and directed.
2700
-
-
Supply and fixing LED flood light fitting 150 Watt operating on 230 V AC outdoor type with high pressure die cast aluminium housing along with prismatic polycarbonate optic with IP-66 ingress protection having 4kv in built and 10kv external surge protection with top opening driver cover for easy maintenance,efficiency not less than or equal to 110lm/W,CCT 5700K complete with driver,lamp bracket with impact and corroison resistant including thermal management in multiple optics including MS clamps,bolts,nuts,washers,anchor fastners etc suitable for fixing security light,complete all as specified and directed.Make: Bajaj,Jaguar,Wipro, wipro Cat No LF07-152-060-50-V5,Jaguar cat No LFLDSLM150XC,Bajaj Cat No- GLEAMF165L WH SYPCSDV2 Notes: The bidder shall submit warranty certificate of minimum 3 yrs from OEM of LED lumanaries with LM-79 and LM-80 test certificate from NABL certified Lab.
10
-
-
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections including of 10A SP MCB all as specified and directed . Make - Hensel /National/Sintex
10
-
-
M&L for fabricating and fixing MS angle iron 25x25x5mm, flat iron and brackets etc for fabrications for fixing flood light in wall ,including nuts,bolts,washers,welding to shapes for fabrication of structure to fix flood light including necessary cutting/jointing/welding with one coat of red oxide and two coats of synthetic enamel paints complete all as specified and directed.
10
-
-
M&L for cutting existing road in hard dense soil, dense soil not exc 45 cm in wide & 60cm in depth and getting out excavated material for laying GI tube, returning filling & well ramming watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplus soil complete all as specified and directed.
5.4
-
-
S& F of HDPE pipe 100 mm dia PN-10 confirming to ISI for laying in ground, road crossing etc for pipe/cable protection including necessary fittings,clamps for supports, etc complete all as specified and directed. Make-Plasto,Prayag,Supreme
20
-
-
M&L for reinforced cement concrete nominal mix M-30 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed. (Note - Reinforcement and form work will be measured and paid separately).
24
-
-
S&F CRS TMT Steel bars 10mm dia and overcut to length,bent to shape required,including cranking,bending spirally for hooping for coloumns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips,complete all as specified and directed.
119
-
-
S&F CRS TMT Steel bars 8mm dia,cut to length,bent to shape required,including cranking,bending spirally for hooping for coloumns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips,complete all as specified and directed.
192
-
-
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished flat surfaces of concrete, complete all as specified and directed.
96
-
-
Supply, errect and connection of hot dip galvanised octagonal poles of height 6 mtr with 130mm bottom A/F & 70mm top A/F made up of 3mm thick High Tensile sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed.Make-Bajaj/Crompton/Philips. Note-1. Two run of cable protection pipe (UPVC) shall be provided in PCC foundation and rate shall be included in the quoted rates 2.Foundation of pole shall be as per OEM recommendation and the cost of the same deemed to be included in the rate quoted against the item.
60
-
-
Supply and fixing LED street light fitting 60 Watt operating on 230 V AC outdoor type with high pressure die cast aluminum housing along with prismatic polycarbonate optic with IP-65 ingress protection having 4kv in built and 10kv external surge protection with top opening driver cover for easy maintenance,efficiency not less than or equal to 120lm/W,CCT 5700K complete with driver,lamp bracket with impact and Corrosion resistant including thermal management in multiple optics including MS clamps,bolts,nuts,washers,anchor fastners etc suitable for fixing security light,complete all as specified and directed.Make: Bajaj,Jaguar,Wipro Jaguar cat No-LSRT015060XC,Bajaj Cat No-ENXT P-72L WH PO PC SD,Wipro Cat No-LR02-671-XXX-57-XX Notes: The bidder shall submit warranty certificate of minimum 3 yrs from OEM of LED lumanaries with LM-79 and LM-80 test certificate from NABL certified Lab
60
-
-
S&F for Multistranded Copper Conductor PVC insulated, 1100 volts grade cable of 3 Core 1.5 Sqmm size for interconnection of cable looping box to street Light Fitting fixed on the pole complete all as specified and directed Make-KEI,Finolex,Benlo
480
-
-
M&L for earthing using GI earthing strip 25 x 4 mm complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 25 x 4 mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, making good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with 8mm dia TMT bars 150mm c/c both ways with one lifting handle made of 8mm dia MS bar funnel wire mesh and testing on completion including making test point on wall as per SSR specification complete all as specified and directed.
8
-
-
Supply install, testing and commissioning in renewal of LT Power Distribution Board (CPRI Approved) outdoor type Powder coated cubical type factory fabricated made out of 3 mm thick CRCA sheet & suitable for 3 Phase 4 wire 415 V, 50 Hz tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated in an approved factory having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust/ vermin proof & general construction confirming to IS : 8623/93 and size to accommodate all accessories/fittings, compartmentalized in construction to accommodate all accessories. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval not more than 500 mm through out the length of the TPN bus bar. The Cubicle incomer MCCB as well as outgoing MCCBs shall have copper TPN extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coated sleeves. The cubicle shall have a bottom channel of size 50x50x6 mm duly coated with zinc metal coating having thickness not less than 100 microns. A detachable predrilled powder coated gland plate should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both sides having chromium plated 19mm dia fancy locks,louvers and air vent gasket for natural flow of air. The Panel shall be powder coated with pure polyster siemens grey structural RAL 7032 shade. The degree of protection of outer shell shall be IP-54. All control wires shall be with 2.5 sqmm multistrand copper conductors and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs. A detachable predrilled gland plate of thickness 2.0 mm powder coated should be used at the bottom. Adhesive type gasket shall be used to make panel vermin proof/ Dustproof Complete as specified and consisting the following :- a) Electrolyte copper bus bar 200 Amps capacity for 3 Phase and neutral Make of LT Panel - Lotus Power Gear Pvt Ltd/Universal Switch Gear control/Power Switch Gear & Control,Vidyut Technologies india Pvt Ltd.
4
-
-
INCOMER
b) MCCB FP 63 Amps 415 Volt 32 KA - 1 Nos (Incoming) Make - Wipro/ABB/Schneider/L&T OUTGOING
c) MCB TPN 32 Amps, 16 KA 415 Volts- 1 Nos (Outgoing) Make-Wipro/ABB/Schneider/L&T
d) MCB SPN 32 Amps, 10 KA 230 Volts - 1 Nos (Outgoing) Make-Wipro/ABB/Schneider/L&T
e) Digital VAF Meter - 1 Nos Make- L&T,Schneider,C&S
f) LED based indication lamp for RYB phase,set of three- 1 Set Make: L&T,Schneider,C&S,Havells
g) Selector switch for voltmeter and Ammeter.- 01 nos.
h) Timer switches 415 V three phase of 20 Amps rating with contactor-2 No's
Note - (i) The cost of PCC for foundation and platform deemded to be included in the rate quoted aginst this item.
(ii) The layout drawing of the panel, its fittings/components and the specifications shall be got approved by the contractor from the GE before panel fabrication.
-
-
-