Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date11 Jan 2025
Closing Date6 Feb 2025
Tender Amount₹ 10,00,000
Costs
EMD
₹ 20,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_692922_1Tender No
82695/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Dehydration and filtration of transformer oil filled in transformer installed at different locations,testing of oil after dehydration to achieve dielectric strength not less than 40 KV for 1 minute in 2.5 mm electrode gap as per relevant IS and to bring the acidity with the permissible limit complete all as specified & as directed.
1250
-
-
... More
Supply & fixing in replacement of ceramic HV bushing with gun metal bushing stud, nuts and washers for transformer of capacities 160/250 KVA complete all as specified & as directed.
3
-
-
... More
Supply & fixing in replacement of ceramic LV bushing with bushing stud (Brass Metal), nuts and washers for transformer of capacities 160/250 KVA complete all as specified & as directed.
3
-
-
... More
Supply and filling fresh tansformer oil confiming to IS 335 having die electric strenght up to 50 KV with oil testing kit 2 mm thick top up transformer complete all as specified & as directed.
210
-
-
... More
Disconnecting of incoming & outgoing cable from both side of transformer indoor/ outdoor type including all accessories, loading unloading and transportation from site to work shop as per site requirement and back to site after carried out repairs & assembling , including connection for the capacity 160 KVA to 250 KVA and commissioning and testing complete all as specified and directed by Engr In Charge.Note: Gasket set,LT/HT Side ceramic bushing,spindle for HT/LT side,rewinding ,dehydration of oil shall be measured and paid separately in respective items.
3
-
-
... More
Taking out defective HT winding and M& L for rewinding of HT coil with super enameled best quality copper wire of existing gauge with superior quality insulation material for transformer of capacity 160 to 250 KVA complete all as specified & as directed.
45
-
-
... More
M& L for rewinding of LT coil with super enameled best quality copper wire of existing gauge with superior quality insulation material for transformer of capacity 160 to 250 KVA complete all as specified & as directed.
55
-
-
... More
Assembling of HV and LV coils including necessary insulation with paper boards and varnishing, making internal connections, drying, removal of moisture from core and coils, heating the complete and carried out all necessary tests for transformer capacity 160 KVA to 250 KVA complete all as specified and directed by Engr In Charge.
2
-
-
... More
M& L for improvement of insulation resistance value for core & coil winding by cleaning complete, applying varnishing & necessary insulation material and baking in oven terminal connection inside the transformer complete all as specified and directed by Engr in Charge.
2
-
-
... More
Disconnecting the HT termination,Supply and fixing HT Boot cover at cable end and VCB complete all as specified & as directed.
2
-
-
... More
Disconnecting all incoming and outgoing connection of HT 22KV under ground cable,detecting fault by applying surge current 1.5 times the rated current & finding exact location of fault with PICO equipment and repair the same immediately complete all as specified and as directed by the Eng.in.Charge.Note: Necessary Jointing kit to be measured and paid separately in respective items.
2
-
-
... More
M&L for Servicing/testing the following equipment of distribution Transformer 22/0.44kv: (a) IR Value of winding (b) De carbonizing all cable connection.(c) Earth Resistance Checking (d) Replacement of Silica gel Complete all as specified and as directed by Eng.in.Charge
5
-
-
... More
Painting of transformer after cleaning the body surface of transformer by rubbing with emery paper to remove oil stains,dust etc and applying one coat of synthetic enamel paint by spray paint incl writing SM No./MES No. of capacity 160/250 KVA Transformer complete all as specified and directed by Eng.in.Charge.
5
-
-
... More
Supply and fix Breather assembly of approved make filled with silica gel suitable for transformer of capacity 160/250 KVA distribution transformer complete all as specified and as directed by Eng.in.Charge.
3
-
-
... More
Supply and fix brass spindle for terminal on HT side threaded complete with nut,washer etc of suitable dia for transformer of capacity 160KVA to 250KVA complete all as specified and directed by Engg.in.Charge.
3
-
-
... More
Supply and fix brass spindle for terminal on LT side threaded complete with nut,washer etc of suitable dia for transformer of capacity 160KVA to 250KVA complete all as specified and directed by Engg.in.Charge.
3
-
-
... More
Supply and fix ceramic bushing and gasket on LT side of transformer of capacity 160 to 250 KVA 22000/433 Volt distribution transformer complete all as spd and directed by Engg.in.Charge
3
-
-
... More
Supply and fixing in replacement of complete gasket(Cork sheet) 6mm thick with and incl conical rubber bush complete all as specified & as directed.
3
-
-
... More
M&L for Servicing/ Testing HT 22KV VCB Panel rupturing capacity 26/3 MVA, 1250 Amps including Calibration,decarburizing , troubleshooting,repairing, replacement of unserviceable spare parts and adjustment of over current relay,earth fault relay, checking of vaccum of interrupter, including connected accssories cleaning of fixed and moving contacts, testing of electrical wiring system, Ammeter, voltmeter ,VAF meter, selector switch all illuminated indications for R Y B phase, by qualified technical person complete all as specified and by the Engr- in- Charge.
Note:-Necessary spare parts, need to replace will be paid in respective item.
4
-
-
... More
Supply only Voltage indicator lamp(Red,Yellow and Orange) 220 V,AC for servecing/replacement the HT 22KV VCB complete all as specified and directed by Engg.in.Charge.
2
-
-
... More
Supply only Control Fuse,HRC,2/4/6 Amp for servecing/repairing the HT 22KV VCB complete all as specified & as directed.
3
-
-
... More
Supply only HT Tape for servecing/repairing the HT 22KV VCB complete all as specified & as directed.
6
-
-
... More
Supply only Monoplast tape for servicing/repairing the HT 22KV VCB complete all as specified and directed by Engg.in.Charge.
6
-
-
... More
Supply only high voltage over current protection relay for servicing/repairing the HT 22KV VCB complete all as specified & as directed.
3
-
-
... More
Supply only Earth fault relay for servicing/repairing the HT 22KV VCB complete all as specified and directed by Engg.in.Charge.
3
-
-
... More
Supply only Auxillary contacts for servicing /repairing the HT 22KV VCB complete all as specified and directed by Engg.in.Charge.
2
-
-
... More
Supply only SPACE heater alongwith thermostat for HT VCB Panel including electric connection complete all as specified and directed by Engg.in.Charge.
4
-
-
... More
Supply only master trip relay suitable for HT 22 KV VCB Panel complete all as specified and directed by Engineer-in-Chrage.
2
-
-
... More
Supply only contact arm suitable for HT 22 KV VCB Panel complete all as specified and directed by Engineer-in-Chrage.
2
-
-
... More
Supply only shunt release coil on, 110 V, DC suitable for HT 22 KV VCB Panel complete all as specified and directed by Engineer-in-Chrage.
1
-
-
... More
Supply only shunt release coil off, 110 V, DC suitable for HT 22 KV VCB Panel complete all as specified & as directed.
1
-
-
... More
Supply only key locks for servicing /repairing the HT 22KV VCB complete all as specified & as directed.
3
-
-
... More
Supply only Switch operating Assembly servicing /repairing the HT 22KV VCB complete all as specified & as directed.
2
-
-
... More
M&L for shutter assembly suitable for HT 22 KV vertical draw type VCB complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
M&L for taking down carefully existing serviceable switch air break, gang operated outdoor, any type of capacity upto 22 KV, servicing to the operating mechanism, greasing etc of all joints for smooth operation, with & including replacement of burnt male/female contact where required, re-fixing the switch air break, gang operated outdoor, testing, complete all as specified and as directed.
2
-
-
... More
Taking down Unserviceable GOD of any capacity and supply and installation HT 22KV/200Amps outdoor type GOD including dropout fuse assembly complete all required at site etc complete all as specifed and directed by Engineer in charge.
2
-
-
... More
Supply & fixing Dropout Fuse 23 SWG complete all as specified & as directed.
2
-
-
... More
S&F in replacement Single phase SMPS based battery backed power pack for Supply Back-up for trip Coil,Protection Relay,Indication,& other Load in HT Panels, working input voltage 90 to 300 Volt AC, output 110 Volts DC with backup for 15-20 min, complete all as specified & as directed.
2
-
-
... More
S&F Lightning arresters HT 22 KV 65 kilo Amp Non linear expulsion type transmission class with standard fittings confirming to IS-3070 (Part-I) 1985, including dismantling & taking down old unserviceable lightning arresters, complete all as specified & as directed.
1
-
-
... More
S&F Disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 22000 Volts, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed.
10
-
-
... More
Supply & laying XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cable with aluminum conductor, 22000 V grade, cross sectional area of 3 core 95 Sqmm in trenches all as specified and directed by Engr In Charge.
100
-
-
... More
Supply & laying un reinforced precast cement concrete cable cover class HV type 1, flat, size 300mm x 180mm x 40mm all as specified & directed by Eng.in .Charge
500
-
-
... More
M&L for earthing complete with Copper earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of copper Strip of size 20x3 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2010 including earthwork, PCC chamber, CI cover, protection and watering pipe, funnel, mesh etc all as required at site and all as directed. Note: (i). 7.5 RM Copper strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately. (ii). Earth resistance of earth pit should be less than 2 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of Copper plate. (iv) Soil registance test if required shall be the responsbility of contractor without any extra cost.
3
-
-
... More
Excavation in trenches , n exc 1.5 m wide and n, exc 1.5 m in depth for foundation, etc. or for shafts, wells cesspits, manholes, peir holes. Etc 1.5 m n exc 10 sqm on plan and n exc, 1.5 m in depth and getting out complete as specified & directed
35
-
-
... More
Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25cm in soft/soil complete all as specified and directed
30
-
-
... More
Removing excavated soil not exc 50m depositing where directed at a level not exc 1.5m above the starting point complete all as directed and specified & directed.
5
-
-
... More
M&L Sand cushioning for UG cable protection/ducts, consolidated sand compacted with clean dry sand all as directed and specified.
7
-
-
... More
Boring for road crossing in any kind of soil/rock strata all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Supply & laying GI pipe light grade of size 50mm dia in trenches and fixing on wall/Poles with help of suitable size MS clamp for cable protection all as directed.
6
-
-
... More
Supply & laying GI pipe light grade of size 80mm dia in trenches and fixing on wall/Poles with help of suitable size MS clamp for cable protection all as directed.
6
-
-
... More
M&L for platform for transformer of size 2000mm x 1500mm x 1200mm with brick masonry construction in cement mortar 1:4, PCC (1:4:8) type D-2, 150mm thick as in foundation, PCC (1:2:4) type B-1, 40mm thick as in floor over sub base PCC (1:4:8) type D-2, 75mm thick, brick masonry step on one side to made access to the top of platform including excavation & earth work in any type of soil including 15mm plastering to brick masonry in CM 1:4 and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and two coats of white wash on plastered surface complete all as specified
1
-
-
... More
M&L for painting of transformer foundation with two coats of OBD after complete scrapping of old paint/whitewash and making good surface all as specified and directed by Engineer-in-Charge.
3
-
-
... More
M&L Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape inclusive of one primer coat, one under coat and one finishing coat of paint complete all as spd and directed by Engg.in.Charge.
0.5
-
-