Military Engineer Services Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Water Storage And Supply
Electrical Works
Eprocure
Opening Date13 Feb 2025
Closing SoonCancelled
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply Only Closing Shaft Assembly.

1

-

-

... More
Supply Only Spring charge Indicator Assembly.

1

-

-

... More
Supply Only Motor cut off limit switch Assembly.

1

-

-

... More
Supply Only Closing Coil Assembly, DC. 12Voltage.

1

-

-

... More
Supply Only Tripping Coil Assemblyy, DC 12.Voltage.

1

-

-

... More
Supply Only Auxiliary switch 6 NO/6NC.

1

-

-

... More
Supply Only Indicating VCB Lamps (RYB) LED type of Shape & Size as per existing complete all as directed. MAKE : TENICK / L&T or equivalent .

3

-

-

... More
Supply Only Push Button element with one NO / NC MAKE : TENICK / L&T or equivelent.

3

-

-

... More
Supply Only HRC Fuse for PTs 11 KV capacity 1 to 16 Amp.

1

-

-

... More
Supply only warm Gear Wheel with Main Shaft Assembly any type

1

-

-

... More
Supply only insulated VI Seprators

1

-

-

... More
Supply only Big Cam Assembly , VCB

1

-

-

... More
Supply only Closing Spring Assembly

1

-

-

... More
Supply only Tripping Spring Assembly

1

-

-

... More
Supply only PT fuse 3.15 Amp

1

-

-

... More
Supply only (VCB) Heater Single Ph, 230 V, AC

1

-

-

... More
Supply and fixing Current Transformer duel core Class - SP10 & Class - I, VA - 15, 11 KV 25/5 Amps resine casting.

3

-

-

... More
Supply and fixing Current Transformer duel core Class - SP10 & Class - I, VA - 15, 11 KV 100/5 or 50/5 Amps resine casting.

3

-

-

... More
Supply and fixing spring charging motor retrofit. For HT VCB 11 KV Make CG, or equivalent

1

-

-

... More
Supply and fixing Vaccum Interruptor , single phase, 11 KV Make CG, or equivalent

1

-

-

... More
Supply and fixing power pack with batter back up suitable for HT VCB 11 KV input voltage 230/110 AC, Output 24/30/48/110/220 V DC , back up 15-20 minutes with LED Indicator.

1

-

-

... More
Supply and fix three phase over current & earth relay, Model- CGI 14N in CG or equvalent, with 3 phase O/C + E/F + High set, 50/51 RYBN, Numerical Relay, Lowest O.C-1s, Highest O/C-1hs, Lower D/F-0s, Highest E/F Ohs, including calibration of relay with existing system so that fault can be arrested in individual panel, all as specified and directed.

1

-

-

... More
Supply and fixing HT HRC fuse suitable for 11 KV HT Load brake switch , breaking cap 40 KA, single phase, as per existing make and model Make CG, or equivalent

6

-

-

... More
Supply, installation, testing and commissionig Battery bank 24 volt,( 12X2V) , 80AH at 10 Hrs discharge rate, self contained, floor mounted, sheet steel, cabinet with two tiers for housing and including low maint batteries with battery charger unit Make: Exide - Model No. UPST-24V-80Ah - sealed maintenance free VRLA battery, initialy charged complete with all accessaries suitable for DC supply of HT VCB, operated from 415 v, 3 phase, 50 Hz ,AC supply.

1

-

-

... More
M& L for Multifunction Meter 630 to 800 Amp Digital type showing V,A,F,Pf Kw,KWH in built Selector switch with CT coiles for three phase. Cat No WL4410100000 of L&T ./ Legrand including taking down old UNSV meters all as specified and directed by Engineer - in - Charge

1

-

-

... More
M & L for Maintenance,servicing and over hauling of 11 KV HT RMU (SF 6 Type at Borgad Top 1st stage Make-sizilucy)) title ref-SABRE VCE 630/800 Amp by complete inspection of various sub- assemblies of RMU mechanism ,cleaning and provided lubrication all moving parts, deoxidizing electrical contacts including replacement of all unserviceable parts for fully function of SF6 unit incl Testing and calibration of all relays complete by authorized testing team of the OEM, for smooth functioning, complete all as directed specified and directed by Engineer in Charge . Note- The rates for dismantling , transporting to civil work shop and back after repair and installation on its original place is deemed to be included in quoted rates.Contractor may visit the site and note the defective RMU before quotaing the rates.

1

-

-

... More
M&L for Onload filtration and dehydration of transformer oil by on load filtration plant machine to achive minimum 40 KV dielectric strength complete and testing the dielectric strength and contents of acid before and after filtration at different locations of 11 KV / 440 V installations all as specified and as directed by the Engineer in charge.

750

-

-

... More
M&L for Filling only new transformer oil for topping up or replacement of transformer oil in the OCB, Oil switch, transformers 11 KV / 440 V at different locations during the process of filtration, all as directed and specified.

200

-

-

... More
Supply and laying synthetic rubber insulated mats 2.5 mm thick fot voltage up to 11 KV for electrical pupose as per IS IS-15652-2006 (superseding IS 5424) suitable for electrical shock safty of sizes 2 MX1M in blue colour complete all as directed.

6

-

-

... More
Disconnected earthing strip from transformer body and neutral at site . Testing of earth resistance of each earthing of transformer (Neutral and Body earthing ) and report to be submitted at AGE E/M Office complete all as directed by Engr in Charge up to 1000 KVA transformer

5

-

-

... More
Disconnected electric supply of transformer at site and Opening the cable box HT& LT side and carried out the insulation resistance test HV to LV and LV to LV of each type of transformer and re-assembleing the same and report to be submitted at AGE E/M Office complete all as directed by Engr in Charge up to 1000 KVA transformer

5

-

-

... More
Taking down carefully transformer at site and dismantling / Opening the same and taking out coil and core assemebly through reputed firm to be approved by GE and carried out minor repair such as as replacement of HV/LV Bushing, termination rod, nut bolts, gaskets etc and re-fixing in position including testing of present di-electric strength of transformer oil and re-assembleing the same complete all as directed by Engr in Charge up to 250 KVA transformer

1

-

-

... More
Supply only non metel Part- HV bushing complete with packing for transformer of capacity up to 500 KVA and for working pressure 11 KV complete all as specified and as directed by Engr-in-charge.

3

-

-

... More
Supply of HT Bushing rod of suitable size for transformer of capacity up to 250 KVA

3

-

-

... More
Supply only non metel Part- LV bushing complete with packing for transformer of capacity up to 250 KVA and for working pressure 11 KV complete all as specified and as directed by Engr-in-charge.

4

-

-

... More
Supply of LT Bushing rod of suitable size for transformer of capacity up to 250 KVA

4

-

-

... More
Supply only main gasket of transformer and other gasket set complete all as specified and directed by Engineer-inCharge

1

-

-

... More
Taking down unserviceable transofrmer and transporting from site / AGE E/M Yard to civil work shop for repair by reputed firm ( Repair workshop decided by Engr-in-charge) Opening the same including taking out coil and core assembly, cleaning and segregate the damaged parts and replacing with brand new parts as directed and Making the transformer ready for use compete including refilling the dehydrated transformer oil and transporting the transformer back to site, fixing in position and commissioning at site complete in all respect capacity up to 250 KVA transformer. Note- Sparemensioned ser no-38 to 42 will bemeassured and paid separately here in after rest of item deemed to be included for making transformer completely operational and smoothworking to give contant voltage output as per crating at . present load.

1

-

-

... More
Supply only super enameled copper winding wire for rewinding of HV side of transformer as per original gauge asprescribe by manufacturing /OEM incuding insulating material such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer complete all as specified and as direcetd by E ngr-in-charge

30

-

-

... More
Supply only super enameled copper winding wire for rewinding of LV side of transformer as per original gauge incuding insulating material such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer complete all as specified and as direcetd by E ngr-in-charge

30

-

-

... More
Supply only silica gel in breathers of transformers of various capacities including taking down of unserviceable silica gel complete all as directed by Engineer-in-charge

10

-

-

... More
Supply only breather assembly air tight made out of metal body and transparent acrylic glass suitable for various sizes of transformer.

1

-

-

... More
Supply only dial type thermometer for measuring winding /oil temperature of transformer and including taking down old UNSV dial type thermometer from the pocket to safe custody.

1

-

-

... More
Maintenance of GOD fixed on two/four pole structure including cleaning and greasing the all connected parts and replacement of HT jumper-3 nos , alligning of GOD and replacement of male and female brass contacts -3 set of 200 Amp incl all repair and maintenance of of GOD for smooth functioning all as specified and directed by the Engr In charge.

2

-

-

... More
Dismantling of old and unservicable cross arms and M&L for cross arms, bracings, supports, clamps and back plates fabricated from strucural steel sections including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated, with & inclusive of one coat red oxide primer & one under coat and one finishing coat of synthetic enamel paint after preperation of surfaces all as specified, as directed by engg in charge.

4

-

-

... More
S& F in reapairs Air Break switch, gang operated triple pole mechanically operated mounted on insulator and steel frame with operating mechanism and locking arrangement worked from ground level for current rating up to 200 amps,11000 volts all including fix and moving contacts, post insulators, operating rod, handle etc complete with necessary connections/ jumpers with suitable ACSR conductor with heavy duty alkathine pipe all as specified by Engineer in charge Make:- jaipuria/Pactil./ Atlas

1

-

-

... More
S& F in reapairs DO Fuse 100 Amp 11 KV complete with insulator mounted on MS channel necessary connections/ jumpers with suitable ACSR conductor all as specified by Engineer in charge Make:- jaipuria/Pactil./Atlas.

1

-

-

... More
Supply & fix in repairs (HT) lightening arrestor expulsion type complete with all fittings, 65 kilo amps discharge capacity working pressure 11000 volts, distribution class including inter connecting with & including GI Strip 25X4mm. duly insulated on pole upto test point.complete all as specified and directed.(Set of Three)

2

-

-

... More
Supply & fix jointing and testing in replacement HT cable jointing kit for 11 KV(earthed) grade cable cold shrink for end termination out door type joint complete with jointing matrial and accessaries suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed raychem/denson/ M-seal.

2

-

-

... More
All same as per item no. 48 here in before but for indoor type end termination joints for cable size of 50 to 95 Sqmm.

2

-

-

... More
All same as per item no. 48 here-in before but for straight through type joints for 50 to 95 Sqmm cable.

2

-

-

... More
Material and labour for locating under ground cable fault (HT /LT) within 06 hrs including Sunday or any holiday using cable fault locator machine carring out necessary excavation and confirmation of fault taking all necessary precautions as directed by Engr-in-charge. Note : If fault not located by the contractor within specified time a recovery of an amount of Rs. 5000/- will be recovered per day.

2

-

-

... More
Material and labour for Painting of transformer 11KV/433V Indoor/Outdoor type with two coat of synthetic enamel grey paint after cleaning and scraping of old paint, oil, rust etc complete including writing SM Nos with white synthetic enameled paint complete all as per specified as directed by Engineer - in - charge of the250 KVA to 200 KVA Capacity.

2

-

-

... More
Supply and mild steel plates chequerred channels, square cut or notched ( ordinary and counter sunk) forming holes without any attachment of steel Fe - 410W ( Gde-E-250) quality - B as in florring and is supproting members of required size and section duly cutting and welding with foundation etc all as directed by Engineer - in - charge.

1

-

-

... More
Material and labour for cable joint/root indicator casted in 350x200x50mm PCC tile duly engraved with 'HT CABLE/LT CABLE / HT CABLE JOINT" in letters duly fixed into the ground with to th minimum depth of 450 mm, PCC casting (1:4:8), type D2 with 20 mm graded stone aggregate minimum size of PCC,duly painted, complete all as specified and as directed by Engneer-in-Charge.

10

-

-

... More
Supply & laying in trenchs or passing through pipe, fixed to pole or as indicated at site, commissioning and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (earthed) with stranded aluminium conductor,11000 volts, grade of size 3 core 95 Sqmm complete all as specified and as directed by Engr-in-Charge including taking out U/S HT Cable from existing position.

200

-

-

... More
Excavation in trenches carefully for taking out or relaying existing/ new servicable HT UG cable not. exceeding 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in soft/loose soil all as directed by Engr-in-Charge.

60.75

-

-

... More
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm all as specified and as directed.

45.75

-

-

... More
Removing of surplus soil to a distance not exceeding 50 mtr and depositing in low lavel where directed at a level not exceeding 1.5 mtr above the starting point all as directed by Engr-in-Chagre.

15

-

-

... More
M&L river sand cushioning/filling completely dry in trenches 8cm below the cable and 15 cm abobe the cable and punned down to a total thicknes of sand 18 cm cpmplete all as specified and as directed by Engr-in-Charge.

12.15

-

-

... More
Supply and fixing un-reinforced precast concrete cable covers class HV,type 1 flat of size 300x180x40 mm from excaveted trench under srl item No.1 herein before and staking properly aside for reuse to a distance not existing 50 mtr as directed at site by Engr-in-Charge.

825

-

-

... More
Supply and fix 80mm dia bore galvanized iron tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.

12

-

-

... More
M&L for Boring of holes under Road, Pavements, Hard Standing by manually at a depth 0.6 Mtr from top surface complete all as specified and directed by Engineer-in- Charge.

20

-

-

... More
Supply & fix earth continuty conductor or main earthing copper strip of 32X6 mm dia for VCB earthing connection as required all as directed by Engg. in charge. Note :- i) the distance between porcelain insulator will be included .

20

-

-

... More
M&L grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots , filling holes and levelling off ground, stacking of serviceable material and removing of serviceable /unserviceable materials to a distance n exc 50 m and clearing site complete all as directed.

5

-

-

... More
M&L for spraying the chemical in sub stn areas (total 3 location ) for buring of the grass once in three month complete all as directed.

6

-

-

... More
S/F danger notice sticker of size 150mmX200mm ,1.6 mm thick mild steel sheet vitreous enameled white with letters, figures and conventional skull and bones in signal red colour complete all as specified and as directed.

20

-

-

... More
M&L for Preparation of old painted surfaces of steel tublar poles HT 11.00 Mtr long & painting two coats of aluminium paint with alternate strip of blue paint at an interval of 1 feet from bottom of pole upto 6 feet height, including existing cross arm/angle iron/clamps/brackets etc & marking of pole numbers in white on black background all as directed at Borgod Top.

20

-

-

... More
M&L for ACSR conductor of HT line ( 3 Nos of weasel conductor ) with new winding on insulators complete all as specified and as directed by Engr-in-Charge.

0.5

-

-

... More
Re stringig of ACSR conductor of HT line ( 3 Nos of weasel conductor )after dismantling old winding from insulator in position up to permisible sag and re winding on insulators with new winding wire complete all as specified and as directed by Engr-in-Charge.

800

-

-

... More
Tree cutting of HT over head line at Borgad Top complete and removing of serviceable /unserviceable materials to a distance n exc 50 m and clearing site complete all as directed.

800

-

-

... More
M&L MDI controller ( maximum demand controller) for HT application at Borgad Top 1-2A in single varient , 50/60Hz with 5% accuracy0.25, 8 MVA module connected current 5 A-0.05VA per phase 96X96X115 mm , IP-52 incl CT/ VT primary. complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
M&L for yearly Inspection of cranes by checking & testing all parts /seafty deviceincluding Load testing and provide inspection report /certificate from authorised rep complete all as specified for the complete with the testing load as recommended by OEM for the rated tonnage of crane for the specific period complete with and including arrangement for safe test load for 0.5 to 2.0 ton cranes . Note :- Load testing is inclusive of shiffting /Transporting the load place to place, unloading will be arranged by the contractor including required ropes,manpower etc for handilling the load.

1

-

-

... More
Repair maintenance of HOT operated travelling (HOT) cranes, once in a month of crane up to 20 mtr span, 0.5 ton to 1 ton capacity, medium duty floor operated comprising of Hoist motor , long travell , installed at Borgad Top including carry out periodical services as per ,repair /maintenance of unserviceable damaged parts such as bearing bushes all type of shoes headers, / broken MS Parts, safety parts, mechanically safety lock , including all connected accessories complete with push button ,inclusive repair of harness wiring of control panel , minor repair to panel ,for safety and smooth functioning of Cranes, cutting wall making good disturbed surface with masonry work to make the existing surface, cable as per requirement or safety operation of cranes, maintenance of unserviceable /worn out parts such as warm wheel, warm shaft, bushes, thrust bearing and necessary packing including cleaning, alignment of gear box assembly after repair/replacement of worn-out parts re-assemble and fixing with existing machine with proper alignment complete maintenance, binding of loose wire at control panel and painting to rust portion of crane.

2

-

-

... More
M & L for Preventive Checks/Breakdown Maintenance/serviceing of DG set by deputing Skilled Service Mechanic to attend the DG set as per the requirement for carrying out scheduled Preventive checks/Breakdown maintenance for smooth functioning of DG set of any Make all as directed by Engineer-in-Charge of following capacities:-

4

-

-

... More
Supply and Fix in Replacement Diesel filter suitable for 75 KVA

1

-

-

... More
Supply and Fix in Replacement Lub Oil filter suitable for 75 KVA

1

-

-

... More
Supply and Fix in Replacement Air filter (inner and outer) suitable for 75 KVA.

1

-

-

... More
Supply and Fix in Replacement Hose Pipe Set suitable for 75 KVA.

1

-

-

... More
Supply and Fix in Replacement V belt Set for 75 KVA

1

-

-

... More
Supply and Fix in Replacement Automatic Voltage Regulator (AVR) as per Existing Complete

1

-

-

... More
Supply and Fix in Replacement VMR Panel for 75 KVA.

1

-

-

... More
Supply and Fix in Replacement Battery Charger 12V,10Amp SMPS Base

1

-

-

... More
Dismantling and taking out the FIP (PT Pump Assy) for repairing by replacing the worn out gasket, filter, suction valve, discharge valve and fixing the same after calibration and testing complete as directed by Engr-in-charge of Gen set of capacity 75/40 KVA .

2

-

-

... More
Dismantling and taking out the dfective self starter assembly from Gen set of capacity 75/40 KVA (12V/24V) form the DG set and re-fixing the same after repair works including replacing the spare parts such as carbon brushes, springs, spring holder bushes, bearings, or any other spare part not mentioned herein but essentially required for proper functioning of the starter assembly complete all as specified and directed.

1

-

-

... More
Supply & Fixing flexible pressure pipe for lubricant oil and fuel for any size/capacity/model/make of DG set incl taking down old one etc complete all as specified.

1

-

-

... More
Dismantling and taking out radiator from Gen set of capacity 75/40 KVA after disconnecting the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins, incl weilding of lekage portion and re-fixing the same after servicing complete and replacement of coolant solution and hose radiator with clips complete all as directed by Engineer-in-Charge.

2

-

-

... More
M & L for Preventive Checks/Breakdown Maintenance/serviceing of DG set by deputing Skilled Service Mechanic to attend the DG set as per the requirement for carrying out scheduled Preventive checks/Breakdown maintenance for smooth functioning of DG set of any Make all as directed by Engineer-in-Charge of following capacities:- (Major Spares Replacement will be Paid Seperately under respective items below) at DG Set 40 KVA Chamarleni.(2 Nos DG set )

8

-

-

... More
Supply and Fix in Replacement Diesel filter suitable for 40 KVA

2

-

-

... More
Supply and Fix in Replacement Lub Oil filter suitable for 40 KVA

2

-

-

... More
Supply and Fix in Replacement Air filter (inner and outer) suitable for 40 KVA.

2

-

-

... More
Supply and Fix in Replacement V belt Set for 40 KVA

2

-

-

... More
Supply and Fix in Replacement Automatic Voltage Regulator (AVR) as per Existing Complete

2

-

-

... More
Supply and Fix in Replacement VMR Panel for 40 KVA.

2

-

-

... More
Supply and Fix in Replacement Battery Charger 12V,10Amp SMPS Base

2

-

-

... More
M & L for Preventive Checks/Breakdown Maintenance/serviceing of DG set by deputing Skilled Service Mechanic to attend the DG set as per the requirement for carrying out scheduled Preventive checks/Breakdown maintenance for smooth functioning of DG set of any Make all as directed by Engineer-in-Charge of following capacities:- (Major Spares Replacement will be Paid Seperately under respective items below) at DG Set 15 KVA at chamarleni. ( 3 nos DG set )

12

-

-

... More
Supply and Fix in Replacement Diesel filter suitable for 15 KVA

3

-

-

... More
Supply and Fix in Replacement Lub Oil filter suitable for 15 KVA

3

-

-

... More
Supply and Fix in Replacement Air filter (inner and outer) suitable for 15 KVA.

3

-

-

... More
Supply and Fix in Replacement V belt Set for 15 KVA

3

-

-

... More
Supply and Fix in Replacement Automatic Voltage Regulator (AVR) as per Existing Complete

1

-

-

... More
Supply only coolant concentrate Make : Valvoline

50

-

-

... More
Material and labour for draining out old engine/lubrication oil from chamber of the DG sets, cleaning of chamber thoroughly and filling new engine/lubrication oil of grade 20W40 complete all as specified and directed.

70

-

-

... More
Supplying, fixing lead acid battery, 12 volts, 150 AH with lead acid suitable for DG set including initial charging (Make- EXIDE / AMRON ) including connction and testing incl taking down old one complete as specified and directed .

2

-

-

... More
Supply only distilled water for batteries.

20

-

-

... More
Material and labour for servicing/repair of AMF Panel of DG Set 75/40 KVA capacity for smooth functioning of the same with renewal / repair of AMF panel, wiring control timer, engine starting relay, contact point repal, AMF relay, HRC fuse of existing rating inclding painting complate for DG sets installed at various pockets at Borgad all as specified and as directed. Note:- The rate quoted by the contractor shall be deemed to included the cost of all minor spares as or any other part not mentioned herein but essential required to make the AMF panel completely functional and no extra payment shall be made for the same.

2

-

-

... More
S&F Current Transformer with CT ratio 100/5 as per sample.

1

-

-

... More
S&F Contactor FP, 3 Phase 63 A FP , AC as per sample

1

-

-

... More
S&F Contactor FP, 3 Phase 40 A FP , AC as per sample

1

-

-

... More
Supply & Fixing in repairs "ON LOAD" type Change over switch 100 Amps TPN front handle operated, on existing LT/AMF Panels, suitable for three phase, 415V, 50 Hz AC supply of following ratings :- Make - L&T/Schneider/C&S/indoasian/HPL

1

-

-

... More
Dismantling and taking out the dfective door lock assembly of any capacity of the DG set and re-fixing the same after repair works including replacing the defective spare parts as reqd at site. complete all as specified and directed.

1

-

-

... More
Taking down old unserviceable street light fittings /high way light /flood light/Watch tower light ) of any type and capacity up to 15 mtr heights and deposited to MES store yard for further disposal.

65

-

-

... More
Supply, Installation, Testing and commissioning LED street light fittings 70 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No TRP-409-70-57-SL-GL-NSG or equivalent in Havells/ Phillips.complete all as specified and directed by Engineer- in-charge..

25

-

-

... More
Supply, Installation, Testing and commissioning LED street light fittings 45 watt with minimum110 lumen/ watt system lumen output .The luminaire should have cool white coloure temperature with minimum 5700 K. The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No LSTS-25-CDL/NL-M or equivalent in Havells/ Phillips/bajaj.complete all as specified and directed by Engineer- in-charge.

25

-

-

... More
Supply, Installation, Testing and commissioning LED Flood light fittings 120 watt with 110 lm/ watt system lumen output . The luminaire should have cool white coloure temperature with minimum 5700K . The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No LFLN-120- CDL/60-M or equivalent in Havells/ Philips.complete all as specified and directed by Engineer- in-charge.

10

-

-

... More
Supply, Installation, Testing and commissioning LED Flood light fittings 80 watt with 110 lm/ watt system lumen output . The luminaire should have cool white coloure temperature with minimum 5700K . The luminaire housing should be made of pressure die cast aluminium Epoxy power coated with wether proof gasket for LEDs and control gear compartments, heat resistance toughened clear glass fixed with SS screw with IP 66 protection, Make Crompton CAT No LFLN-80-WW CDL/60-M or equivalent in Havells/ Philips.complete all as specified and directed by Engineer- in-charge.

5

-

-

... More
Supply & Fix in repair PVC perplex cover glove type with Base plate /holder not less than 8 inch dia suitable for Post top lantern including one nos 7/9 watt LED lamp complete all as specified and directed by Engineer- in-charge.Make - Bajaj / Surya/*havells.

20

-

-

... More
Repairs to High mast light 15/30 Mtr high, by taking down the luminaires mounting frame mechanically and replacing the unserviceable items (paid separately) including lifting the superstructure after repairs and testing complete all as specified and as directed by Engr-in- Charge..

3

-

-

... More
S&F in repair flat twin core 10 sqmm nominal cross sectional area multistand aluminium conductor cable over all PVC shathed 1100 volt grade Heavy duty cable complete all as specified

200

-

-

... More
S&F in repair flat twin core 6 sqmm nominal cross sectional area multistand aluminium conductor cable over all PVC shathed 1100 volt grade Heavy duty cable complete all as specified

200

-

-

... More
Supply & Fix in repair LED Post top lantern weather proof indirect lighting solution Make Cormpton Cat Pt No LPTC-40-CDL or equivalent in Havells/Bajaj.complete all as specified and directed by Engineer- in-charge.

4

-

-

... More
Supply & Fix in repair Post top lantern decorative HERITAGE LED suitable 1X20 Watt retro LED with opel deffuser including LED 20 Watt of Make Crompton Cat Part No LPTH-20-CDL or equivalent in Havells/ Wipro.complete all as specified and directed by Engineer- in-charge.

6

-

-

... More
Supply and fix in repair street light bracket 32/40 mm bore GI pipe/tubing light grade not less than 1.2 Mtr long band to shape with 2 nos MS clamps flat iron 50 x 5 mm for nuts, bolts and washers suitable for Steel/PCC Pole etc and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. Make- Prakesh surya/Swastik/Jindal

10

-

-

... More
Material and labour for cable joint termination box PVC body housing suitable for housing and including 100 amps rated, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tublar pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 amps MCB, SP, 240 volt for street light supply complete all as as directed by Engr-in-charge.

20

-

-

... More
Supply and fix in repairs power contactor, ML-3type Three pole, 440 volt , Auxilary coil voltage 230 Volt, Make- L&T/Legrand/Semiens

2

-

-

... More
Supply and fix in repairs Time digital switch with built in PCB for street light , Make L&T, type DIGICON or equivalent of GEC/ GIC/ Havells.

2

-

-

... More
Supply and laying in trenches/ducts or passing through pipe 1100 volt grade LTUG cable with XLPE insulated armored heavy duty electric cable multistanded with aluminium conductor 1100V grade 4 core cross sectional area 10 sqmm all as specified and directed.

300

-

-

... More
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil all as directed.

40.5

-

-

... More
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm all as directed.

36.5

-

-

... More
Removing of surplus soil not exceeding 50 meter and depositing where directed at a level not exc 1.50 mtr above the starting point all as directed.

4

-

-

... More
Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc and test report Make :- Dura- line/Gemini/Rex. Of size 38mm

300

-

-

... More
Supply and fix 40mm dia bore galvanized iron tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.

20

-

-

... More
M&L for Preparation of old painted surfaces of PCC LT 9.0 Mtr long & painting two coats of cement base paint from top to bottom and painting with alternate strip of blue paint at an interval of 1 feet from bottom of pole upto 6 feet height, including existing cross arm/angle iron/clamps/brackets etc & marking of pole numbers in white on black background all as directed.

50

-

-

... More
M&L for monthly inspection /periodical maintenance/ brake down maintenance incl six monthly servicing of Fire alarm system any type and make of different location of 11 BRD tech area ( Fire alarms, smoke detectors, fire panel , sesor etc ) once in month by checking & Testing to ensure proper function compete all as specified and as directed by Engr-in-charge , comprising of the following. Testing of smoke detectors and fire alarms to be functional Cleaning of fire alarm and other parts to prevent dirt and dust buid-up Ckecking of sesors and wiring to be all functional of CTO Section Make Bosch-03 at Chamar leni.

4

-

-

... More
All as per Item No-39 above but location Borgad Top Make - Bosch-01

4

-

-

... More
Supply ,install,testing & commissioning Addressable photoelectric smoke detector with base Model No HFP-11+ DB-11 of Make Siemens, complete all as specified & as directed by Engineer-In Charge

5

-

-

... More
Supply ,install,testing & commissioning addressable manual call point Model No HMS-S of Make Siemens, complete all as specified & as directed by Engineer-In Charge

1

-

-

... More
Supply ,install,testing & commissioning control relay for module for hooter Model No HTRI-R of Make Siemens, complete all as specified & as directed by Engineer-In Charge.

1

-

-

... More
Supply and lay 2 core 1.5 sq mm armoured FRLS copper cable for interconnecting devices in PVC conduit of 20 mm dia,complete all as specified & as directed by Engineer-In Charge

100

-

-

... More
M&L for carrying out physical inspection and measurement of individual earth pit resistance of each earth pit, every month located in area and maintain the record of its reading month wise and submit to the office monthly for measuring the resistance of individual electrode of LV distribution system and other non-DG/ Transformer by fall of potential test in case fall of potential method is not possible at certain locations then measurement of earth pit resistance shall be carried out in stake less method using current and voltage clamps.() Nos earth pit located in different area of this station shall be measured in each month or all as directed. Pit for measurement of pit resistance including necessary excavation in any type of soil, or braking of hardstanding for inserting of spikes complete all as directed by Engineer-in-Charge. The rate also include to inspect and measure resistance of any type of earth( like conventional or chemical, strip or wire any size) complete. Note- Minimum 22 Earthings per working day and 100 % within a month to be cheked and testing will be carried out, testing equipment should be calibrated and certified from appropriate Govt Authority. Testing of earth resistance should be carried out in presense of the users and record should be furnished to the AGE E/M Office on daily basis, Failing which a recovery @ Rs 500 per eathing per day will be recovered as penalty.

4

-

-

... More
Repair of old earthing for improvement of earth resistance by removing of old pit Chemeber from existing site , disconnecting all earth electrode of any type and size excavated the pit and removing old existing earth plate any type, cleaning the same and burried directly in ground with new bolts,nuts ,washer and check nut of galvanized steel,filling adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode and including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) The material as salt, charcoal, Magnesium sulphate,GI Plate, wire mesh funnel will be measured and paid seprately.

25

-

-

... More
Supply only Salt

500

-

-

... More
Supply only Char coal

500

-

-

... More
Supply only Magnesium sulphate

100

-

-

... More
Supply only Back fill compound (SGI Engineer or equvalent )

50

-

-

... More
Supply only Wire mesh funnel

10

-

-

... More
Supply & fix earth continuty conductor or main earthing lead of 25 x 3 mm copper strip.

50

-

-

... More
Dismantling and taking down dislocated/de-shaped/loose earth contunity conductor down or roof conductor in any position for re-fixing properly or for replacement complete including UNSV insulators/clamps/ saddles ets Aluminum strip of any size. Note :- The quoted rates shall be deemed to be included with cost of T&P and labour required to work on roof top and at lateral faces of existing hangers upto height of 25 Mtrs.

300

-

-

... More
Supply & Fix 25 x 3 mm aluminium strip ( Roof conductor or down conductor) above ground level fixed to wall/ roof duly insulated fixed on and including new porcelain insulators with clamping device or recessed or chases or burried in ground/ floor or drawn in conduit / pipe or fixed to poles or any other indicated situation or for loop earthing etc. Note :- i) The consecutive distance between porcelain insulator will not be more than 40 cm. ii) The quoted rates shall be deemed to be included with cost of T&P and labour required to work on roof top and at lateral faces of existing hangers upto height of 25 Mtrs.

100

-

-

... More
Re-fixing the taken down aluminium strip on roof top/on wall/lateral faces fixed on new porcelain insulator including new GI bolt, nut, washer provide at a distance not more than 40 Cm consecutively. Note :- i) The quoted rates shall be deemed to be included with cost of T&P and labour required to work on roof top at lateral faces of existing hangers upto height of 25 Mtrs. i) The consecutive distance between porcelain insulator will not be more than 40 iii) The cost of porcelain insulators will be paid under relivant item here in under but cost of GI bolt nut, washer etc is deemed to be included under quoted rates.

200

-

-

... More
M&L for GI tubing light grade with all fitting laid in trenches or fixed to wall or ceiling with clamps or fixed to floor complete all as specied and directed of size 40 mm bore.Make : Tata/Jindal/Prakash Surya/Apollo.

10

-

-

... More
M&L for Air termination, single pointed aluminium rod 12 mm dia and 300 mm long, includind dismantling and taking out old unservicable termination complete all as specified and as directed.

25

-

-

... More
M&L in repairs for PCC block on roof top comprising 1:3:6 of required size at places where directed & laying,clamping the strip any size secured on the block with suitable size GI bolt duly grouted, nut bolt washer etc.

1

-

-

... More
M&L for test point terminal block insulated from wall or external surface made of gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screws complete fixed on ebonite sheet 6mm thick fitted on MS flat 50x5mm bent to shape etc complete all as specified and as directed.

5

-

-

... More
M&L in repairs to earthing pit chamber including replacement of PCC chamber, cement concret pit with cast iron miled steel frame embedded in the massonery enclouser finished flushed & PCC cover 10 mm thick (300mmx300mm having locking arrengment hinged to PCC frame all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, complete all as directed.

10

-

-

... More
Supply only PVC insulator for GI/Aluminium strip supporter adequate to accomadate strip of 32 mm with fasteners complete all as specified and directed.

400

-

-

... More
M&L for earthing in repair including taking out GI plate with pipes earthing lead fasteners etc and earthing complete with galvanised steel earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the pl;ate not less than 1.5 Mtr below normal ground level,connected to galvanised iron strip 32x6 mm as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 50 mm bore (light grade) and connected to main switch / MCB DBs box point / LP test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) Filling the pit with black cottan soil brought at site. ii) The excavated soil will be removed & paid separtely.

5

-

-

... More
Supply and laying LT UG cable with XLPE insulated armoured heavy duty electric power cable with aluminium conductor 1100V grade 4 core cross sectional area 16 sqmm laid in trench/duct/floor or passing through pipe all as specified and as directed byengr-in-charge.

100

-

-

... More
All as per item No 1 -here-in-before above but 4 core 25 Sqmm

200

-

-

... More
All as per item No 1 -here-in-before above but 3 1/2 core 95 Sqmm

100

-

-

... More
Taking down old unserviceable Lt cable from trench/wall/roof rectify the defects and re-laying the same in existing place including all earth work all as directed.

100

-

-

... More
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil all as directed.

54

-

-

... More
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm all as directed.

48

-

-

... More
Removing of surplus soil not exceeding 50 meter and depositing where directed at a level not exc 1.50 mtr above the starting point all as directed.

6

-

-

... More
Supply and laying Double walled corruyated (DWC) Duct (Dura- Guard) as per IS-14930 Part - II for LT UG cable protection including coupler, elbows, T- Joint, Bends, etc and test report Make :- Dura- line/Gemini/Rex. of size 38 mm inner dia

300

-

-

... More
All as per item No -8 here-in-before above but 50 mm inner dia

100

-

-

... More
Supply and fix 40mm dia bore galvanized iron tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.

6

-

-

... More
M&L for Boring of holes under Road, Pavements, Hard Standing by manually at a depth 0.6 Mtr from top surface including supply & fix HDPE pipe of 80 mm dia complete all as specified and directed by Engineer-in- Charge.

6

-

-

... More
M & L for Straight through joints (heat shrink type) for LT underground cable including joint kits and labour complete for making joints suitable for aluminium conductor cables 3 1/2 core 35 to 70 Sqmm.

2

-

-

... More
M & L for Straight through joints (heat shrink type) for LT underground cable including joint kits and labour complete for making joints suitable for aluminium conductor cables 3 1/2 core 95 to 120 Sqmm.

2

-

-

... More
Supply & fix MCCB TP, 415 Volts,50 HZ,Thermal magnatic type with 16 KA, 63 Amps

1

-

-

... More
Supply & fix MCCB TP, 415 Volts,50 HZ,Thermal magnatic type with 16 KA, 100 Amps

1

-

-

... More
Maintainance of Automatic power Factor Controlling Panel at ( Borgad Top and Chamarleni ) by Cleaning, Rewiring, Replacement of components like Capacitors, Contactors, MCB/MCCB, APFC Controller/ Relays , Indicating lamps, Instruments Push Buttons, switches, wires cable termination etc. And demo of working Panel with proper relay setting & loadwise capacitor switching at chamarleni

3

-

-

... More
APFC Relay 12 step ,440 V, 5 A as per sample Make L&T -ETACONM008R+ETACONEXP2R+ETACONEXP3R or equvalent in Ebcos/seimens

1

-

-

... More
Push Buttons, Indicating Lamps, Switches as per sample

3

-

-

... More
Indicating Lamps Red R,Y B as per sample

3

-

-

... More
Current Transformer with CT ratio 100/5, as per sample.

2

-

-

... More
Power Contactor , 3 Phase 1No+0NC suitable for 3 KVAR Capacitor

2

-

-

... More
Power Contactor , 3 Phase 1No+0NC suitable for 5 KVAR Capacitor

2

-

-

... More
Power Contactor , 3 Phase 1No+0NC suitable for 10 KVAR Capacitor

1

-

-

... More
Capacitor Heavy duty Cylindrical type / Box Type ( 1 KVAR ), 440 Volt, 50 Hz as required at existing Panel .

2

-

-

... More
Capacitor Heavy duty Cylindrical type / Box Type ( 2 KVAR ), 440 Volt, 50 Hz as required at existing Panel .

2

-

-

... More
Capacitor Heavy duty Cylindrical type / Box Type ( 3 KVAR ), 440 Volt, 50 Hz as required at existing Panel .

2

-

-

... More
Capacitor Heavy duty Cylindrical type / Box Type ( 4 KVAR ), 440 Volt, 50 Hz as required at existing Panel .

2

-

-

... More
Capacitor Heavy duty Cylindrical type / Box Type ( 5 KVAR ), 440 Volt, 50 Hz as required at existing Panel .

1

-

-

... More
Excavation in trenches n. exc 1.5 Mtr width and n.exc 1.5 mtr deep for foundation, laying GI pipes in hard and dense soil and getting out,complete all as specified and as directed by Engineer-In-Charge.

30

-

-

... More
Returning filling in incl spreading leveling watering and well ramming in layers not exceeding 25 cm levers of soil, complete all as specified and as directed by Engineer-In-Charge.

26

-

-

... More
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point, complete all as specified and as directed by Engineer-In-Charge.

4

-

-

... More
Taking up or down old rusted water tubing and connections fixed to wall floor, celing for bore of 15 mm dia , complete all as specified and as directed by Engineer-In-Charge.

50

-

-

... More
All as per item no-4 but bore 20 mm dia

50

-

-

... More
All as per item no-4 but bore 25 mm dia

50

-

-

... More
All as per item no-4but bore 40 mm dia

50

-

-

... More
All as per item no-4 but bore 50 mm dia

50

-

-

... More
Supply & Fix GI water tubing medium grade with all fitttings and fixed to wall, floor,in trenches, ceiling for bore of 15 mm diameter, complete all as specified and as directed by Engineer-In-Charge.

20

-

-

... More
All as per item no 9 above but of bore 20 mm dia

20

-

-

... More
All as per item no 9 above but of bore 25 mm dia

20

-

-

... More
All as per item no 9 above but of bore 40 mm dia

20

-

-

... More
All as per item no 9 above but of bore 50 mm dia

20

-

-

... More
Fixing only old serviceable water tubing medium grade received from item No 5 here in before and connected with new fittings of medium grade as required including cleaning, cutting, threading and fixed to wall, floor, ceiling for bore of 15 mm diameter , complete all as specified and as directed by Engineer-In-Charge.

30

-

-

... More
All as per item no 14 above but of bore 20 mm dia

30

-

-

... More
All as per item no 14 above but of bore 25 mm dia

30

-

-

... More
All as per item no 14 above but of bore 40 mm dia

30

-

-

... More
All as per item no 14 above but of bore 50 mm dia

30

-

-

... More
Supply & Fix in replacement of Bronze gate valve (Hex type) ISI marked screwed both ends of 50 mm diameter Art No 1006 of Make: Zoloto or Equivalent in SEIKO/GEM complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
All as per item no 19 above but of bore 40 mm dia

1

-

-

... More
All as per item no 19 above but of bore 25 mm dia

1

-

-

... More
All as per item no 19 above but of bore 20 mm dia

1

-

-

... More
All as per item no 19 above but of bore 15 mm dia

1

-

-

... More
Supply & fix in repair Contactor ML-02 Aux coil voltage 230 V , Make L&T or Equivalent in Siemens/Standard complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
All as per Sl. item no 24 above but Contactor ML-03,Aux coil voltage 230 V

1

-

-

... More
All as per Sl.item no 24 above but Contactor ML-04, Aux coil voltage 230 V

1

-

-

... More
Material & Labour for run lead joint suitable for 80/100/150 mm dia spigot and socket end pipe including necessary excavation, cutting of existing pipe etc complete all as specified and as directed by Engineer-In- Charge

2

-

-

... More
Dismantling old unserviceable valve chamber & Material & Labour for construction of valve chamber of size 0.90x0.90x0.90 mtrs internal dimension complete of brick masonary of 23 cm thick in cement mortar 1:6 on PCC 1:4:8 foundation 75 mm thick using 40 mm graded stone aggregates & coping in PCC having wall thickness of 0.26 mtrs 1 :3:6 10 mm thick at the top of brick wall using 20 mm graded stone aggregates and 10 mm thick plastering in cement mortar 1:4 on exposed brick or concrete surfaces & MS cover of 3.15 mm thickness including 40 mm×40mm× 6 mm angle iron frame fixed with the same size of angle iron hold fast,handle with locking arrangement & two coats of synthetic enamel paint over one coat of red oxide primer on steel surface and two coats of white wash on plastered concrete surface ,complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
All as per item no 31 aove but of size 1.20x1.20x1.20 mtrs internal dimension complete

1

-

-

... More
Supply & Fix Cast iron detachable joint(mechanical joint) of 80 mm dia,complete including all excavation work and curtting of existing pipe etc all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
All as per item no 38 above but of size of 100 mm dia,

1

-

-

... More
All as per item no 38 above but of size of 150 mm dia,

1

-

-

... More
Material & labour to collect water sample from 793 SU chamarlene area in container & sending it to govt approved NABL lab , to carry out chemical analysis as well as organoleptic & physical & General Parameters & bacteriological parameter Including Residual free Chlorine test from approved lab Every month & rate quoted are deemed to be quoted with this item.) (Note: - Report from approved NABL lab shall be submitted by 15th of the Month.)

11

-

-

... More
Material & Labour for disconnecting the motor from pumpset & transporting it to workshop rewinding the electric motor after dismantaling the stator and rotor, removing the damaged winding, cleaning the slots, warnishing the stampings, slots and rewindung the stator with super enamelled best quality copper winding wire of the suitable gauge and number of turns/coils as per the existing/manufactureres winding pattern of electric motor of 7.5 HP. Warnishing, drying and reasssembling, testing etc, complete all as specified and as directed by Engineer-In-Charge.

1

-

-

... More
Material & Labour for Repairs to centrifugal pump set of Make :Kirloskar 7.5 HP capacity,dismantling the pump set carefully from its connected electric motor including disconnecting and taking out the electric motor,transporting the pumpset to workshop for complete overhauling the pump set with complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Repairs to vacuum pump of 50 LPM capacity Kirloskar coupled with electric motor 3 PH 440V , 50Hz, 1450 RPM after disconnecting the electric connections,transporting the pumpset to workshop and transporting the pumpset to workshop ,dismantling the pump set carefully from its connected electric motor including disconnecting and taking out the electric motor,transporting the pumpset to workshop for complete overhauling the pump set complete all as specified and directed by Engineer-in-Charge.

1

-

-

... More
Material & Labour for Pumping out water and sediments from overhead resorvoir of capacity 75000 ltrs situated at chmarleni area and carrying out cleaning complete after scraping out fallen paint funai, voids etc. by using mechanical scrappers brushes and cleaning with fresh water and applying lime / stable bleaching powder solution diluted in water drying for two hours washing out with clean water, cleaning the external area of the OH resorvoir including the walk way arround, by removing all the debries & clearing the bushes,vegetation/weeds/salvage/scrap .

1

-

-

... More
Material & Labour for Pumping out water and sediments from the semi underground sump of capacity 250000 ltrs situated at chamarleni area and carrying out cleaning complete after scraping out fallen paint funai, voids etc. by using mechanical scrappers brushes and cleaning with fresh water and applying lime / stable bleaching powder solution diluted in water drying for two hours washing out with clean water, cleaning the external area of the sump including the walk way arround by removing debries & clearing bushes ,vegetation/weeds around 50 metre radius of sump,Prepration of surfaces, Applying two coats of white wash inside the sump, and painting of inlet outlet pipe CI/DI/MS pipe at tank/sump at base,dome ,pumpset & associated pipeline with synthetic enamel paint as directed by Engineer-In-Charge .etc ,and marking a portion of size not exceeding more than 1 Sq M with black syntetic enamel paint over a coat of primer and writing in white synthetic enamel paint the sump capacity,date of cleaning , due for cleaning & painting all the valve chambers & valves and valve cover with synthetic enamel paint and marking flow direction area and area of supply etc. complete all as specified and directed by Engineer-In- Charge.

1

-

-

... More
Material & Labour for Pumping out water and sediments from the semi underground sump of capacity 120000 ltrs situated at chamarleni area and carrying out cleaning complete after scraping out fallen paint funai, voids etc. by using mechanical scrappers brushes and cleaning with fresh water and applying lime / stable bleaching powder solution diluted in water drying for two hours washing out with clean water, cleaning the external area of the sump including the walk way arround by removing debries & clearing bushes ,vegetation/weeds around 50 metre radius of sump,Prepration of surfaces, Applying two coats of white wash inside the sump, and painting of inlet outlet pipe CI/DI/MS pipe at tank/sump at base,dome ,pumpset & associated pipeline with synthetic enamel paint as directed by Engineer-In-Charge .etc ,and marking a portion of size not exceeding more than 1 Sq M with black syntetic enamel paint over a coat of primer and writing in white synthetic enamel paint the sump capacity,date of cleaning , due for cleaning & painting all the valve chambers & valves and valve cover with synthetic enamel paint and marking flow direction area and area of supply etc. complete all as specified and directed by Engineer-In- Charge.

1

-

-

... More
Material, labour & suitable vehicle for making one trip for transportation of 4000 ltrs of clean & hygienic potable water, in water bowser three times in a week ( checked by MI room, borgard) to be delivered to Borgad hill top approximately 22 kms from borgad(chamerlene area) passing through plain and hilly area (of 3100 feet height) & hair pin turns. (Note: The vehicle provided shall be fully insured updated with all vehicle paper. The driver & helper should have suitable life insurance. ii) The water to be delivered three times a week or as reqd . (Note : Failing to provide water bowser at borgad top under any circumstances whatsever, contractor shall be penalise for paying 10000 per trip in the form of recovery. Water shall be loaded form MES pump house at chamarlene with locking arrangement, representative of user unit to ensure its portability and shall be submitted to sub division on monthly basis. If water tanker found rusted/ not suitable to carry the potable water, the sane trip shall be rejected by MES and no claim on this account shall be admissible by the MES)

140

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.