Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Dec 2023
Closing Date5 Jan 2024
Tender Amount₹ 36,40,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed by Engineer -in-Charge.

104

-

-

... More
Taking up the un reinforced precast concrete cable cover of any type from the existing trenches.

6650

-

-

... More
Supply and laying un reinforced precast concrete cable cover class HT, type-I, flat size 300 mm x 180 mm x 40 mm laid in trenches.

2250

-

-

... More
Laying only un reinforced precast concrete cable cover as obtained from item no 5 here n before of class HT, type-I, flat size 300 mm x 180 mm x 40 mm laid in trenches.

4400

-

-

... More
Supply, spreading in trenches sand cushioning with dry and cleover and under the cable for protection of cable,complete all as directed(Punned thickness shall be measured for payment)Note: Thickness of sand cushioning shall be measured after punning and consolidating of sand.

98

-

-

... More
Taking out old unserviceable underground cable HT/LT,PVC insulated, PVC sheathed armored heavy duty aluminum conductor form pole, wall and trenches etc after disconnecting complet all as directed.

1300

-

-

... More
Supply and laying XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 70 sq. mm.Note- some place ACSR conductor will be schedule of credit. Make :- Havells/ Polycab/ Gloster

200

-

-

... More
Supply and laying XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 95 sq.mm Note- some place ACSR conductor will be schedule of credit. Make :- Havells/ Polycab/ Gloster

400

-

-

... More
Supply and laying XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 120 sq.mm. Note- some place ACSR conductor will be schedule of credit. Make :- Havells/ Polycab/ Gloster

500

-

-

... More
Relaying HT cable 11000/22000 volt grade of any size any type as obtaing from item no-9 here in before all as directed.

200

-

-

... More
Reaying GI pipe medium grade 80 mm dia for protection of cable all as directed.

24

-

-

... More
Reaying GI pipe medium grade 100 mm dia for protection of cable all as directed.

24

-

-

... More
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm

2

-

-

... More
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm

4

-

-

... More
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm

4

-

-

... More
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm

4

-

-

... More
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm.

3

-

-

... More
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm.

3

-

-

... More
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 22 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm

1

-

-

... More
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm

1

-

-

... More
Taking down unserviceable Aluminium cable lug 120/185 sqmm and supply with fixing the same all as directed. Make:-Dewel,M-Seal

18

-

-

... More
Taking down unserviceable Aluminium cable lug 95 sqmm and supply with fixing the same all as directed. Make:-Dewel,M-Seal

18

-

-

... More
Taking down unserviceable Aluminium cable lug 70 sqmm and supply with fixing the same all as directed. Make:-Dewel,M-Seal

18

-

-

... More
Dismantling and taking out old unserviceable steel tubular pole of any size and type after breaking PCC, incl necessary earth work and removing from site complete all as directed.

10

-

-

... More
Supply & Erect Steel sewaged tubular poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified of type 410 SP-55 (11.0 Mtrs Long) including Painting with two coats of aluminium paint over a coat of red oxide primer complete after preparation of steel surfaces and writing letters / Numbers not more than 10 cm high by Black paint all as directed.. .

10

-

-

... More
Taking down unserviceable danger notic board,Supply and FixingDanger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, forHT, 25x20cm size

20

-

-

... More
Painting of HT Electrical pole of any height including cross arm, clamp etc with two coats of aluminium paint over a coat of red oxide primer complete after preparation of steel surfaces and writing letters / Numbers not more than 10 cm high by Black paint all as directed.

100

-

-

... More
M&L for earthing complete with galvanised Steel earth plate electrode of size 600x600x6mm thick burried directly in ground with (earth pit not less than 2.25mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire of size 4.0 mm dia by means of nuts, bolts, check nuts, washers of galvanised Iron or Steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion all complete.

8

-

-

... More
Supply and fix earth strip of size 25 x 4 mm galvanised iron strip fixed to wall/over head reservoir on batten or recess or chases or buried inground or drawn in conduit /pipe fixed on poles insulated as per Engr-in-Charge.

30

-

-

... More
Cutting & trimming of tree trunks/ branches having grith not more than 50 mm, falling on or likely to fall on LT over head electrical line for clearence of 3.0 meter on ground from the nearest conductor/pole /earth etc .& disposal of unservicable materials to distance not exc.50 mtrs .& clearing of site all as directed by Engr -in-Charge. Note:- The distance between two poles is measured as one span.

400

-

-

... More
M&L for provision of PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.

2

-

-

... More
M & L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed.

2

-

-

... More
M & L for plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed.

2

-

-

... More
M & L to find out fault location in 11000 V /415 V UG Cable of any size by using cable fault locator directed by all as specified and directed by Eng in charge. Note:-Contractor must bring cable fault locator at site within 24 hours of intimation otherwise recovery @ Rs 1000/Hr will be charged after 24 hours.

5

-

-

... More
Material & labour for cable route indicator made out of Aluminium plate 80 MM dia, 6 mm thick & fixed over M.S angle iron of size 30 x 30 x 6 mm, 60 cm in length duly painted with Synthetic enamel BLUE paint suitable for LT cable all as specified & including embedded in PCC (1:3:6) type C1 of size 30 x 30 x 20 cm in ground complete all as specified.

20

-

-

... More
Dismantling and removing ACSR conductor of any type from pole after disconnecting all connection on insulator etc all as directed.

7

-

-

... More
Supply & fixing ACSR conductor of any type and Size incl binding, on insulator all as directed

3

-

-

... More
Restringing/Fxing only ACSR conductor of any type and Size incl binding wire, retrived from item Srl No -39 all as directed

4

-

-

... More
Dismantling cross arms of MS channel or angle iron section etc complete and setting aside for reuse/replacement with in 50 mtr all as directed.

9

-

-

... More
Supply and fix cross arms, bracing, support, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shapes or size including one primer coat, one under coat and one finishing coat all as directed.

6

-

-

... More
Fixing only retrieved serviceable cross arms, bracing, support, clamps ,retrived from item Srl No -43 all as directed.

3

-

-

... More
Dismantling the insulators of any type/size/voltage.Testing with magar and keeping aside serviceable insulator for refixing all as directed.Note: Refixing/Replacement of new items measured and paid in respective seperate items.

96

-

-

... More
Supply and fix pin type insulator, Polymetric/poreceline , vitreous, white/brown including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut 150 mm height 150 mm dia 11000 volt grade all as specified.

30

-

-

... More
Fixing only serviceable pin type insulator, pin type insulator any type and size obtained against item ser No 46 here in before.

30

-

-

... More
Supply and fix disc type insulator Polymetric/ poreceline vitreous,/Polymetric 145 mm height and 255 mm dia ball and socket type white/brown of 11000 volt grad all as specified .

18

-

-

... More
Fixing only serviceable disc type insulator any type and size, obtained against item ser No 45 here in before.

18

-

-

... More
Taking down unserviceableGOD,and supply and fixing Triple pole, mechanically operated mounted on insulator and steel frame, with operating mechanisum worked from ground level GOD 11 KV heavy duty, for current rating 400 amps all as directed.Make:Pactil,Jaipuria,HEI

4

-

-

... More
M & L for DO fuse single pole 11000 volt grade up to 25 Amps

60

-

-

... More
Repair and comrehensive maitanence to 11 KV VCB distribution line for the the following feeder from MRS under GE Dehu road. The scope of work is as under:- (a) To identify reasion for HT line brackdown. (b) Immediat repair the HT line. ( c) replace the unserviceable material. Note:-(i) The material for repair HT line will be measured and paid seperately in respective items of shedule "A". (ii)Providing safty equiptment for maintanence staff. (iii) Insurance of maintanence staff will be provided by the contractor. (vi) The maintanence/serviceabilty of HT VCB completed immediately any fault occured at any time. Part A :- Comprehensive Maintenance and repair of breakdown for 11 HT overhead line from MRS to Garden city (Garden Feeder) under GE Dehuroad all as directed (Noted : Length of feeder Approx-15 Km)

200

-

-

... More
All as per item no 52 here in before but comprehensive maintanence and repair of brackdown for 11 HT overhead line from MRS to 29 FAD(Center feeder) under GE Dehuroad all as directed.(Noted: Length of feeder approx -24KM)

350

-

-

... More
All as per item no 52 here in before but comprehensive maintanence and repair of brackdown for 11 HT overhead line from MRS to Ashok nagar, COD(Ashok nagar feeder ) under GE Dehuroad all as directed.(Noted: Length of feeder approx -15 KM)

200

-

-

... More
All as per item no 52 here in before but comprehensive maintanence and repair of brackdown for 11 HT overhead/Under Ground line from MRS to Kehinya Pump house, COD(Keniya feeder) under GE Dehuroad all as directed.(Noted: Length of feeder approx -9 KM)

100

-

-

... More
All as per item no 52 here in before but comprehensive maintanence and repair of brackdown for 11 HT Under Ground line from MRS to Kehinya Pump houseMAP Qtr(MAP feeder) under GE Dehuroad all as directed.(Noted: Length of feeder approx -4.5 KM)

100

-

-

... More
All as per item no 52 here in before but comprehensive maintanence and repair of brackdown for 22 HT overhead line from MRS to147 unit location(Unit 147 feeder) under GE Dehuroad all as directed.(Noted: Length of feeder approx -8 KM)

100

-

-

... More
Repair and comrehensive maitanence to 22/11 KV Switch yard,GOD with distribution line for the the following feeder from MRS under GE Dehu road. The scope of work is as under:- (a) To identify reasion for HT line brackdown. (b) Immediate repair the HT line. (c) replace the unserviceable material. Note:-(i) The material for repair HT line will be measured and paid seperately in respective items of shedule "A". (ii)Providing safty equiptment for maintanence staff. (iii) Insurance of maintanence staff will be provided by the contractor. (vi) The maintanence/serviceabilty of HT VCB completed immediately any fault occured at any time.

100

-

-

... More
M&L for Servecing/ testing indoor type HT 11KV vertical draw out type VCB of repturing capacity 800/630 Amps including Calibration,trouble shooting,repairing,replacement of unserviceable spare parts and adjustment of over current relay,earth fault relay, checking of vaccum of interrupter, including connected accssories cleaning of fixed and moving contacts, testing of electrical wiring system, Ammeter, voltmete ,VAF meter, selector switch all illuminated indicationes for R Y B pahse, by qualified technical person from OEM, all as directed.Note:- (a)Necessary spare parts, need to replace will be paid in respective item).Make: Simens/crompton greaves/ L&T/Power Tech.

9

-

-

... More
Supply the following items for servecing /repairing the HT 22 KV VCB (i) Indicator LED Lamp,(Read,Yellow,and Orange)110 V,AC,for HT 22 KV VCB Make - L&T

9

-

-

... More
Closing Coil,110V,DC,suitable for HT 11 KV VCB Make - Siemens

2

-

-

... More
Shunt trip coil on,24V ,DC,suitable for HT 11 KV VCB Make - Siemens

3

-

-

... More
Control Fuse ,HRC,2/4/6 Amp,suitable for HT 11 KV VCB Make - L&T

9

-

-

... More
Motor cutoff switch,suitable for HT 11 KV VCB Make - Areva

1

-

-

... More
HT Tape

12

-

-

... More
Monoplast Tape

12

-

-

... More
Digital volt meter 96x96mm,0-500V,Aux supply 110V,AC,suitable for HT 11 KV VCB.

1

-

-

... More
Digital Ammeter Make - Conzerve DM - 3258 /DM 3310 suitable for HT 11 K V VCB

2

-

-

... More
Auxilary switch on block magnet,suitable for HT 11 KV VCB Make - Siemens

2

-

-

... More
Male &Femal Spout assembly,suitable for HT 11 KV VCB Make - Siemens

2

-

-

... More
CT for VCB,suitable for HT 11 KV VCB Make - Siemens

1

-

-

... More
Over Current realy suitable for HT 11 KV VCB Make - Siemens ERL Modle No - PC:05821,In 4/5 Amp , frquency - 50 Hz , Vx - 43-280V DC/110V AC

1

-

-

... More
Master trip relay suitable for HT 11 K V VCB Make - ERL /EASUN REYOLLE operating voltage -110 Volt DC .

1

-

-

... More
Digital VAF meter , EM 6400 suitable for HT 11 K V VCB

3

-

-

... More
Contact arm assembly from HT 11 kV VCB suitable for Siemens braker

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.