Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date22 Jan 2025
Closing Date17 Feb 2025
Tender Amount₹ 36,87,000
Costs
EMD
₹ 94,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_694284_1Bid Award Id
ViewTender No
GE I R AND D GNR TOKEN 89 OF 2024 2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
S & F structural steel work as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410-W (Gde- E-250) quality-B complete all as specified and directed.
6000
-
-
... More
M &L two coats of synthetic enamel paint to steel surface over a coat of red oxide primer exc 10 cm width or girth incl preparation of new surfaces complete all as specified and as directed.
100
-
-
... More
M & L for preparation of old painted surfaces of steel & Iron of any description over 10 cm width or girth and applying one coat of synthetic enamel paint (1st quality) including necessary scaffolding required for painting work & safety measures at any height of bldg complete all as specified and directed.
120
-
-
... More
Taking down of cement plaster of any description including racking out of joints hacking for keys and scrubing down with water etc complete all as specified and directed.
700
-
-
... More
M&L for rendering 15mm thick in two layers, 5mm thick using WPC @3% by weight of cement over 10mm thick on cement concrete block masonry/concrete surfaces in cement mortar 1:4 finished surfaces even and smooth without using extra cement, complete all as specified and directed.
400
-
-
... More
M&L for rendering 15 mm thick on brick surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
300
-
-
... More
Supply only WPC complete all as specified and directed.
60
-
-
... More
M&L for preparation of surfaces and applying 2mm thick wall care putty in two layers over new plaster surfaces internally complete all as specified and directed.
300
-
-
... More
M&L for two coats of oil bound distemper over a coat of primer on internal surfaces of wall complete all as specified and directed.
300
-
-
... More
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43litre/10sqm over and including priming coat of exterior primer applied @ 0.90litre/10Sqm over Old/New surfaces of wall including necessary scaffolding required for painting work, safety measures etc complete all as specified and directed.
800
-
-
... More
Taking down chowkats or frames with shutters (without taking off shutters from frame) area exc.1.5 sqm and not exc.4 sqm each complete all as specified and directed.
10
-
-
... More
Taking down chowkats or frames with shutters (without taking off shutters from frame) area not exc.1.5 sqm each complete all as specified and directed.
14
-
-
... More
Taking down shutters of any description, area not exc.1 sqm each complete all as specified and directed.
2
-
-
... More
S & F for pressed steel frames of size 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, as per ISI mark, including PCC (1:3:6), type C-0,( using 12.5 mm graded stone aggregates) as in filling of pressed steel frames complete all as specified and as directed .
70
-
-
... More
Supply and fix for 30mm thick flush shutters solid core construction, with block board core and plywood face panels, commercial type on both sides including second class hard wood plain cover fillets 35X6mm all around the shutters complete all as specified and directed
19.3
-
-
... More
S & F mild steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
21
-
-
... More
S & F mild Steel ventilator with top hungshutter including hinges, steel pegstay complete all as specified and directed.
1.3
-
-
... More
S & F for factory made solid Panel PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 4mm thick moulded PVC sheet on the front face and 4mm moulded prelam colour PVC sheet on back face wirth wood free EPS, fixed in frame at site as per specification and drawing including fittings complete all as specified and directed.
2.1
-
-
... More
Supply and fix for solid PVC door frame of size 50mm x 47mm, made out of 5 mm thick plain colour PVC sheet, reinforced with mild steel square tube complete all as specified and directed.
6
-
-
... More
Supply and fix for aluminium powder coated minimum 50 micron, louvered ventilator with provision of exhaust fan using ‘Jindal” aluminium section or equivalent make as specified including glass 3mm thick ordinary quality, frosted and stainless steel wire mesh 0.36mm dia wire and 1.40mm aperture etc complete all as specified and directed.
2
-
-
... More
S & F for aluminium powder coated minimum 50 micron, three track sliding window with two glazed shutters, one 4mm thick float glass ordinary quantity and one shutter of stainless steel wire mesh 0.36 mm dia wire and 1.40mm aperture including good quality of bearing handle, locks, PVC rubber lining etc complete all as specified and as directed. Catlouge numbers of Jindal company or equivalent make as specified. Sections of Jindal company : Three track bottom – 20957, Three track top/vertical – 20958,Handle – 20606, Interlocking – 20605, Top and bottom – 20604 complete all as specified and directed.
5
-
-
... More
S & F for anodised aluminium frame (powder coated minimum 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified complete all as specified and directed.
10
-
-
... More
S & F for anodised aluminium door shutters (powder coated minimum 50 micron) aluminium section weighing 0.55 kg/ m including necessary joining, cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified complete all as specified and directed.
20
-
-
... More
S & F for 300mm long aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, ISI marked, complete all as specified and directed.
18
-
-
... More
S & F for 300mm long brass sliding door bolts with sand or die cast brass hasp, staple (bolt type) and fixing bolt with roller or drawn brass bolts, ISI marked complete all as specified and directed.
15
-
-
... More
S & F for 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
14
-
-
... More
S & F for 150 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
18
-
-
... More
S & F for butt hinges, 100mm size, mild steel cold rolled, medium weight complete all as specified and as directed.
12
-
-
... More
Supply and fix for 75mm size butt hinges, extruded brass with mild steel hinge pin, bright polished and fixed type D-11 complete all as specified and directed.
14
-
-
... More
Supply and fix for floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, overall length of cover plate 150mm complete all as specified and directed.
8
-
-
... More
Supply and fix for 100mm size brass handles, extruded, fabricated type, polished complete all as specified and directed.
8
-
-
... More
Supply and fix for 150mm size extruded aluminium alloy handles fabricated type anodised complete all as specified and directed.
7
-
-
... More
Supply and fix for 300mm, mild steel, ordinary rat tail rod pattern spring (helical spring) including roller and roller plate complete all as specified and directed.
8
-
-
... More
Supply and fix for aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed
5
-
-
... More
Supply and fix in repairs for floor door stopper of brass body and tongue with hard drawn steel spring of over all length of cover plate 150mm complete all as specified and directed.
8
-
-
... More
Supply and fix in repairs for floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, overall length of cover plate 150mm all as specified and directed.
7
-
-
... More
Supply and fix in repairs for 150mm size extruded aluminium alloy handles fabricated type anodised complete all as specified and directed.
9
-
-
... More
M&L for preparation of new surface of wooden and applying two coats of synthetic enemal paint over a coat of zinc chrome primer as complete all specified and directed
30
-
-
... More
M & L 100 mm thick for plain cement concrete type B-0 , 1:2:4 12.50mm graded aggragate finishing concrete surface even and smooth as in subbase complete all as specified and directed.
700
-
-
... More
M & L for Plinth protection 50 mm thick in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth without using extra cement complete all as specified and directed.
320
-
-
... More
M & L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade A complete all as specified and directed.
4
-
-
... More
M&L for precast cement concrete block masonry with solid blocks of PCC 1:3:6 type C-1 using 20 mm graded stone aggregate, exc. 10 cm in width and setting in CM 1:6, complete all as specified and directed.
7
-
-
... More
M&L for rendering 10mm thick on cement concrete block masonry/concrete surfaces in cement mortar 1:6 finished surfaces even and smooth without using extra cement complete all as specified and directed.
30
-
-
... More
M&L for one coats of cement base paint on old surfaces of wall including preparation of surfaces complete all as specified and directed.
1000
-
-
... More
M&L for one coats of distemper oil emulsion, on old surfaces of wall/ceiling including preparation of surfaces complete all as specified and directed.
750
-
-
... More
M&L for one coats of white wash on old surfaces of wall/ceiling including preparation of surfaces complete all as specified and directed.
1000
-
-
... More
S & F for sheet glass 4mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
200
-
-
... More
S & F in Stainless Steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
12
-
-
... More
M & L for RCC nominal mix Type B-0 1:2:4 (12.50 mm graded aggregate) slabs supported on walls, beams and columns in floors, roofs, slab projections, landings, balconies, canopies, deck slabs and in shelves and the like including scaffolding of any height any discription complete all as specified and directed.
6.75
-
-
... More
Supply and fixing TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed.
800
-
-
... More
Excavation in post hole (or similar holes) each n.exc 0.5 cum and getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm watering and removing surplus soil to a distance n.exc 50m and making good in hard/dense soil complete all as specified and directed.
14
-
-
... More
M & L for PCC 1:2:4 type B-2(40 mm graded aggregate) in foundation filling mass concrete and like complete all as specified and directed.
2
-
-
... More
Formwork to flat sides and soffits of slab floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
20
-
-
... More
M & L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick set jointed and pointed in neat cement slurry with grey cement and pigment as in floors including15mm thick screed bed in cement mortar 1:4, 25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone agg) over 75mm thick plain cement concrete 1:4:8 type D2 complete all as directed.
70
-
-
... More
M & L for Machine pressed precast cement concrete interlocking paver block rubberised any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade including 15mm thick screed bed in Cement Mortar 1:4 over 25mm thick PCC 1:2:4 type B0 (using 12.50mm graded crushed stone agg sub floor over 75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) sub base complete all as specified & directed.
90
-
-
... More
Surface dressing n exc 15 cm deep and getting out in soft /loose soil complete all as specified and directed.
160
-
-
... More
M&L for Hardcore 100 mm thick gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed
16
-
-
... More
M & L 75 mm thick PCC 1:4:8 Type D 2 using 40 mm graded stone aggregate as in sub base surface finished even and rough to receive floor topping complete all as specified and directed.
120
-
-
... More
M & L 50 mm thick PCC type B-1, 1:2:4 (20mm graded aggregate) as in floor complete all as specified Finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
120
-
-
... More
E/M PORTION
Taking down carefully aluminium / copper point wiring complete (light, fan socket & power) including unserviceable fixtures and fittings such as switches ceilimg roses pendents regulators sockets etc complete removing material for taking credit & making good disturbed wall / floor etc complete all as specified and directed.
78
-
-
... More
Taking down sub main wiring complete including fitting and fixtures, removing materials for making good disturbed surfaces of walls, floors, roof etc, complete all as specified and directed.
105
-
-
... More
Taking down carefully unserviceable DBs any type/size With MCCBs/ MCBs/ Isolator etc and disconnecting and making good disturbed surfaces complete all as specified and directed.
17
-
-
... More
Taking down carefully old light fittings and removing for taking credit complete all as specified and directed.
94
-
-
... More
M&L for point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through heavy duty PVC conduit fixed in walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly including concealed modular flush boxes modular cover plates with frame mounting for housing the switches, socket outlets etc complete all as specified and directed (a) One light point controlled by one way switch.
42
-
-
... More
(b) One fan/exhaust fan point controlled by one switch and one regulator.
12
-
-
... More
(c) One 3 pin switch socket outlet point 5 Amps on independent board.
8
-
-
... More
(d) One 3 pin switch socket outlet point 5 Amps on same board with other switch.
8
-
-
... More
All as per item here in before but with copper conductor cable 2.5 Sqmm size for one 3 pin socket outlet, 15 amp independent complete all as specified and directed.
8
-
-
... More
S & Fix modular switch 1 way 6A, 1 module
70
-
-
... More
S & Fix modular switch1 way 16A, 1 module
8
-
-
... More
S & Fix modular socket out let 6A 2/3 on combined 2 module
16
-
-
... More
S & Fix modular socket out let 6A/16A-2/3 pin combined 2 module
8
-
-
... More
S & Fix Ceiling rose surface backlite 65x50mm 3 terminals complete.
34
-
-
... More
S&Fix fan regulator electronic 2 modular type volts AC 50 HZ ,300 Watts,4step complete all as specified and directed.
12
-
-
... More
S & Fix Batten for single or twin LED Tubelight with integral LED driver, available in single / double side connection CRCA batten suitable for mount LED tube rod 1 x 18 watts including necessary electric connections 3 core 1 sqmm insulated copper wire from ceiling rose to tube light fitting complete all as specifed and directed.
42
-
-
... More
S & Fix LED Tubelight (single side connection) with very high efficiency suited for installation in existing tubelight luminaire with G13 lamp holders to give glare free light with necessary fixing arrangement etc complete all as specifed and directed.
42
-
-
... More
S & Fix 30 Watts LED new generation energy saving and environmental friendly long life LED building light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded in PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 complete all as specifed and directed.
8
-
-
... More
Supply and Fix 25 watts Gate light fitting New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete all as specifed and directed.
2
-
-
... More
Taking down the defective ceiling fan of any sweep and make after disconnecting electrically & mechanically and examine & carry out the servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, startor rotor & applying the lubricant / grease to the bearing including applying one coat of painting, replacing of broken canopy, re-fixing, testing in all respect for smooth running complete.
10
-
-
... More
Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Five star rated with brushless direct current motor (BLDC) and taking down existing old fan to the store complete all as specified and directed .
2
-
-
... More
S&Fix MCB DB ETPN 4 ways,with metal double door, IP -43 protection suitable for MCCB as incommer and MCB as out going, VTPN DB's 415 volt 3 phase complete with appropriate size copper bus bar and neutral link as required at site and including cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site complete all as specified and directed.
1
-
-
... More
S & Fix sheet metal enclosure distribution board SPN, 4 ways 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs complete all as specified and as directed.
8
-
-
... More
S & Fix sheet metal enclosure distribution board SPN, 2 way 240 volts, single door, suitable for mounting MCBs all as specified and as directed.
8
-
-
... More
Supply and fixing MCB Four pole, 415 volts, 63 Amps, rupturing capacity 16 KA, in the DB complete all as specified and directed.
1
-
-
... More
Supply and fixing MCB Three pole, 415 volts, 32 Amps, rupturing capacity 16 KA, in the DB complete all as specified and directed.
2
-
-
... More
S & Fix of MCB single pole and neutral, 240 volts, 6 to 40 Amps, rupturing capacity 10 KA, ‘C’ series complete all as specified and directed.
7
-
-
... More
S & Fix of MCB single pole, 240 volts, 6 to 40 Ampere, rupturing capacity 10 KA, ‘C’ series complete all as specified and directed.
32
-
-
... More
M & L for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable, multistranded through and including suitable size of PVC concealed conduit with its accessories complete all as specified and directed for the following :-
(a) 2x1.5 sq mm and 1x1.5 sq mm as earth wire.
Note : 2 Runs of 1.5 Sqmm cable, 1run of 1.5 Sqmm wire & PVC conduit shall be measured and paid as one unit.
85
-
-
... More
(b) 2x6.0 sq mm and 1x6 sq mm as earth wire Note : 2 Runs of 6.0 Sqmm, 1 Run of 6.0 Sqmm wire & PVC conduit shall be measured as one unit.
20
-
-
... More
M&L for Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good, cutting not exc 20 cm in stone/ concrete block or slab wall grith all as specified and directed by Engr-in-Charge
50
-
-
... More
M & L Earthing complete with galvanised steel earth plate electrode 60x60cmx06mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point complete all as specified or indicated including testing on completion. Note : Earth lead wire 4.0mm dia of 7.5m length is deemed to be included in quoted rates.
1
-
-
... More
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Hard / dense or any type of soil including forming bottom surface etc complete all as specified and directed.
24.3
-
-
... More
Returning, filling in including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
21.06
-
-
... More
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 50 mtr above the starting point complete all as specified and directed.
21.24
-
-
... More
Supply lay and testing LT UG cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of the following size :-
(a) 3.5 Core 50 Sqmm
190
-
-
... More
(b) 2 Core 6 Sqmm
20
-
-
... More
Supply & Laying 50 mm outside dia double wall corrugated pipe (DWC) ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size couplers for jointing of pipe all as per site requirement complete all as specified and directed.
170
-
-
... More
M&L for cutting of bituminous road / floor for laying of pipe / cables not exceeding 30 cm wide and not exceeding 60 cm deep including refilling with material and watering well ramming / compacting and making good with PCC 1;2;4, type B-1, 100 mm thick complete all as specified and directed by Engr-in-Charge.
12
-
-
... More
M &L for GI pipe ''light grade'' for road crossing / on wall / on pole for cable protection of 40 mm dia size complete all as specified and directed.
12
-
-
... More
Supply Fabricate, install, connect, test and commission Outdoor type dust & Vermin proof LT electrical panel board, CPRI approved 1100 volts, 50 Hz AC supply, fully compartmentalised for cable chamber and busbar chambers with adequate space made out of 3.15 mm thick CRCA sheet for load bearing like all over body, front and back cover with hinges and aldrops with DC locks CRCA poweder coated and 2.0 mm thick MS Sheet for non load bearing and portions, complete with one coat of powder coating including suitable angle iron/ flat iron frame work/ supports bottom 50x50x6 mm MS channel as base and chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated and connection wirings with FRLS copper conductor complete mounted on PCC pillars foundation, cable connection using new lugs complete with danger notice all as specified and comprising of the followings:-
(i) Existing cables which removed from old panel board will be fixed with new lugs during fixing in new panel board (if required) (ii) Getting of approval for Panel board drawing from Engr-in-Charge is necessary before fabrication. (iii) All swith gears should be fixed with 06 mm thick Fibre sheet Make: MES & CPRI approved make. (iv) All MCCBs fixed with extended rotary handles ROM. (v) Adequate space and independent compartment given to MCCBs & switch gears as directed. (vi) Adequate space given to Each MCBs for easy cable connection and working.
Incoming : a) LED/Neon indicator bulb in RYB Colour - 1 Set. (b) 4 No aluminium Bus bar 200 amps with chamber (c) Digital Multi function meter for showing Amps (upto 500 Amps) and Voltage (upto 500 voltage) with suitable CT and PT. (d) MCCB 4 Pole, 415 V, Adjustable thermal & adjustable magnetic type, 125A with breaking capacity 36 KA - 01 Nos.
Out going: (a) MCB 4 Pole, 415 V,adjustable type,40A - 02 Nos (One space for spare MCB to be provided) (b) MCB Single Pole and Neutral, 220 V,adjustable type, 32 A - 10 Nos (One space for spare MCB to be provided) (c) Suitable cap of timer dial type with contactor. (d) suitable cable gland for incoming and outgoing cable