Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Nov 2024
Closing Soon26 Nov 2024
Tender Amount₹ 49,00,000
Costs
EMD
₹ 98,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682840_1Tender No
88614/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
TENDER INVITING FOR REPAIR / REPLACEMENT OF HT ELECTRICAL SYSTEM, HT CABLE, HT POLES, GOD, VCB CALIBRATION, EARTHING OF E/M INSTALLATION UNDER GE (N) AHMEDNAGAR
BOQ Items
Returning and filling in, including spreading and levelling, water and well remming in layers not exc. 25cm all as specified and directed.
230
-
-
Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed.
30
-
-
Supply, laying, testing & commissioning of HT 11 KV (Earthed) ISI marked XLPE insulated screened PVC bedded, electric power cable (heavy duty) with aluminium conductor 11000 volts grade,circular screened with extruded semi conducting compound in combination with copper tape , inner sheath of PVC tape galvanized steel strip flat , around and overall PVC sheathed, armoured conforming to IS 7098 Part II, 1985 amended upto date, of size 3 core 120 Sqmm, ISI marked, laid in trenches or passing through pipes/ducts including taking down old cable of any size all as specified and as directed.
200
-
-
Supply, laying, testing & commissioning of HT 11 KV (Earthed) ISI Marked XLPE insulated screened PVC bedded, electric power cable (heavy duty) with aluminium conductor 11000 volts grade,circular screened with extruded semi conducting compound in combination with copper tape , inner sheath of PVC tape galvanized steel strip flat , around and overall PVC sheathed, armoured conforming to IS 7098 Part II, 1985 amended upto date, of size 3 core 95 Sqmm, ISI marked, laid in trenches or passing through pipes/ducts including taking down old cable of any size all as specified and as directed.
500
-
-
Supply, laying, testing & commissioning of HT 33 KV (Earthed) ISI marked XLPE insulated screened PVC bedded, electric power cable (heavy duty) with aluminium conductor 33000 volts grade,circular screened with extruded semi conducting compound in combination with copper tape , inner sheath of PVC tape galvanized steel strip flat , around and overall PVC sheathed, armoured conforming to IS 7098 Part II, 1985 amended upto date, of size 3 core 300 Sqmm, ISI marked, laid in trenches or passing through pipes/ducts including taking down old cable of any size all as specified and as directed.
60
-
-
Supply and fixing in replacement of HT single core power cable 11 KV ,ISI marked ( earthed) strandred of size 95 Sqmm , compacted, circular,aluminium conductor, conductor screen with extruded semiconducting compound XLPE Insulated, insulation screening with extruded semiconducting compound in combination with copper tape,aluminium round wire armored and FRLS PVC inner and outer sheathed,oxygen index cable confirming to IS 7098(Part II) 2011 up to date amendments complete all as specified.
680
-
-
Notes for item No 6 to 9 above :- 1. Excavation and earthwork , GI pipe, cable protection will be measured and paid for separately 2. Cable shall be tested at high voltage test before & after laying. 3. No straight through joint will be permitted inside pipe or duct. 4. Cost of straight through joint if any deemed to be included in cost of cable.
-
-
-
Supply & lay HDPE DWC pipe 110mm bore for laying of HT cables etc complete with all accessores all as specified and directed.
650
-
-
S&F steel tubing GI light grade of size 80mm bore dia for cable protection passing under road / floor or for fixing to poles all as specified and as directed.
30
-
-
M&L for cable jointing kit for 11 KV grade cable for straight through heat shrinkable joint suitable for XLPE armoured aluminium conductor cable of size 3 core 95 Sqmm all as specified and directed.
3
-
-
All as per item NO 13 above but 120-185 Sqmm 3 core
2
-
-
M&L for end termination cable jointing kit for 11 KV grade cable heat shrinkable joint, out door suitable for XLPE armoured aluminium conductor cable complete with jointing materials and accessories suitable for 3 core 95 Sqmm all as specified and directed.
7
-
-
All as per item NO 15 above but 120-185 Sqmm 3 core
7
-
-
All as per item NO 15 above but 240-400Sqmm 3 core
4
-
-
M&L for end termination cable jointing kit for 33 KV grade cable heat shrinkable joint, out door suitable for XLPE armoured aluminium conductor cable complete with jointing materials and accessories suitable for 3 core 300 Sqmm all as specified and directed.
4
-
-
M & L for checking of HT UG 11 KV XLPE faulty cable with HT UG cable fault locating testing machine, rectifing the fault, putting the jointing kit and charging the cable as all as specified and directed. Approx length 650 RM for each Job. (The rate for excavation, removing of old cable, laying after repairs is demmed to be included in the rate quoted by the contractor).
3
-
-
Dismantling of existing unserviceable HT / LT poles of any size and type from its position carefully and removing from the site and necessary excavation and earth work in any type of strata, demolition of concrete, disconnecting of conductor etc all as specified and as directed .
5
-
-
Supply, erecting and fixing in replacement of true vertical position of steel tubular swaged pole, 11 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-55, conforming to relevant IS, including one primer coat of red oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of botton portion up to 1.8 mtr length all as specified and provide circular bend 1 No of width 2 cm complete all as specified and directed. (Excavation and earth work , foundation concrete and PCC coping shall be measured and paid separately)
5
-
-
M&L for cement concrete (1:4:8 ) type D2 using graded stone aggregate as in foundation for pole including necessary form work all as specified & directed.
0.5
-
-
Demolition of Pole coping and depositing where as directed.
2
-
-
M&L cement concrete (1:3:6 ) type C1 using graded stone aggregate as in foundation for pole including necessary form work all as specified & directed.
2
-
-
Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing complete all as specified and as directed.
1
-
-
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, botls, washers, welding bending cold or hot, drilling holes for bolts, in any shape or size as indicated or irected and inclusive of one coat of red oxide primer, one under coat and one inishing coat of aluminium paint all as specified and as directed.
1
-
-
Dismantling of unserviceable insulator of any type complete from its position and removing all as specified and as directed.
40
-
-
M&L for pin type, porcelain, vitreous, brown or green insulator including one galvanised mild steel spindle, steel washers and one galvanised nut of size 150mm height, 150mm dia for 11000 volts grade complete all as specified & directed.
20
-
-
M& L for disc type, pocelien, vitreous, white or brown 145mm hieght, 255 mm dia ball and socket type complete with tension assembly clamps for conductor for 11000 volts grade single disc assembly complete all as specified & directed.
20
-
-
Dismantling carefully the existing unserviceable HT/LT overhead line ACSR conductor fo any size from its position by necessary disconnecting of conductor and removing complete .
1.5
-
-
supply and stringing new ACSR conductor (Weasel/ Ferret) for over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size all as specified and as directed. (Note :- (a) Jumper on cutout point/2 pole structer/4 pole structure shall be provided with PVC insulated sleeve. (b) Rate is inclusive of jumper & tree branch cutting to make a safe distance from over head line.)
1.5
-
-
S&F in repairs/replacement of GI continuous earth wire 4mm dia on cross of poles for guarding including binding with aluminum wire 16 SWG etc. and dismantling of old broken guarding complete all as specified and directed
0.5
-
-
M&L for restringing of HT over head line consisting of 3 conductors by dismantling, taking down, repairing wherever required including cutting, re-jointing andrestringing in situ, with proper sag, binding to insulator with and including aluminium binding wire complete all as per specified and directed.
300
-
-
S&F jumpers in replacement made out of 6/1 x 2.59 mm weasel ACSR conductor in and including PVC alkaline pipe and nuts, bolts etc all as specified and as directed.
50
-
-
S&F jumpers in replacement made out of 6/1 x 4.72mm DOG ACSR conductor in and including PVC alkaline pipe and nuts, bolts etc all as specified and as directed.
30
-
-
Dismantling of unserviceable stay assembly carefully including stay wire, including M&L for necessary excavation and earth work in any type of soil, demolition of PCC of any type and removing from site al as specified and as directed.
4
-
-
S&F in replacement of galvanized MS stranded stay wire of size 7/4mm including necessary binding straightning complete all as specified and directed.
0.5
-
-
S & F in replacement of Loop type insulators ,vitreous porcelain, white , brown or green, large size with over all dimensions 140mm, clearance of hole 25.5mm including necessary cutting , jointing all as per directed by Engr-in- charge.
30
-
-
S&F stay assembly complete with accessories as shown in Electrical Plate No 1 of SSR 2009 (Part I) using stay rod 20mm dia, including clamps made out of 50 x 6mm MS flat, MS galvansied stay plate 300mmx 300mm x 6mm and galvanised thimble including insulator 90x140mm and conductor all as specified and as directed. (loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately
4
-
-
M & L for replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps of size 25x4mm, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
50
-
-
M&L for prunning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 1.5 Mtr of tree both side of the OH line with JCB, hydrolic vehical, Cutter and all tools, plants etc all as directed by Engineer-in-Charge
Note : (i) Distance between pole to pole will be measured and paid. (ii) Any breakdown of line caused during punning shall be made good without any extra cost. (iii) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening. If any mishappening occures the contractor will be solely responsible for it.(iv) ladder/vehical/tansport required for tree cutting shall supply by contractor at his own arrangement rate of vehical/jcb/ladder/manpower included in quited rate.
17
-
-
S&F in replcement of vertical type air break switch, gang operated, tripple pole, mechnically operated, outdoor type, with all fittings and accessories mounted on and including HT 11 KV porcelain insulators ( 9 Nos) and steel channel frame, GI operating rod 25 mm dia of suitable length to worked from ground, including locking arrangements , suitable for 11000 volts, 400 Amps current rating complete including dismantling existing one all as specified and as directed.
6
-
-
Repair / Maint of air break switch by replacing stationary and moving contacts, flexible copper chord, GI nuts, bolts etc including alingment for smooth functioning from ground level all as required at site and all as specified & directed.
10
-
-
S&F in replacement of HT 11 KV out door non-linear type lightening arrestor with mountings, accessories complete fixed on cross arms of two pole structure / GI flat strip and connect with same size of ACSR conductor encashed in PVC alkathine pipe with all fittings connected to earth strip with nuts, bolts and washers, transmission class having discharge capacity of 65 KA and rupturing capacity 5 KVA and suitable for working pressure 9 KV RMS compelete including taking down old lightning arrestor all as specified and as directed including dismantling existing one all as specified and as directed.
2
-
-
S&F drop out fuse unit, explusion type for out door air break gang oprated switch, single pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts and washer etc synthetic bounded fuse tube complete with line capcity suitable for current carrying capacity upto 400 Amps all as directed including taking down old one all as specified and as directed
6
-
-
M&L for replacement of earthing of poles/system with galvanised earth plate 60x60 cm x 6 mm thick electrode of size and 32 x 6mm GI strip buried vertically in ground not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level and connected to copper strip dia by means of nuts, bolts and washers and encased in and including 15 dia GI medium grade pipe upt 2.4 mtr height form ground level fixed by MS flat iron clamp 40mm x 5mm with nut, bolt and washers, GI strip fixed to base along pole and connected to over head line for providing earthing to HT pole/feeder AB switch LA complete with charcoal dust, salt packed around plate 150 mm thick including watering GI pipe, medium grade 40 mm dia with blanking cap 1.5 mtr long fixed to funnel with wiremesh complete with PCC chamber and RCC chamber over all as per Electrical Plate No 3 of SSR Part I - 2009 incl excavation and earth work in any type of starta and testing on compeltion.
(Note: Any length of GI strip and 15 mm dia GI medium grade pipe shall be provided as per actual requirement at site).
13
-
-
Supply & install in replacement of GI strip 32 mm x 6 mm buried ground/floor/surface/roof including taking doown existing GI Strip complete all as specified and directed
60
-
-
Supply & fix in replacement of Copper strip 32 x6 mmComplete with saddles and fixing screws on including epoxy Insulater for Fitting the strip.including Taking down existing Al/cu strip complete all as specified and directed.(note: Rate included with Insulater)
20
-
-
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 20 mm at 11KV substations / Near DP structures after through cleaning, anti grass treatment etc all as per pecified and as directed.
50
-
-
Supply and fix in replacement of basic numerical relay, wide range with facility over current,phase fault ,short circuit,earth fault,instantaneous witn connected accessories complete all as specified and directed.
10
-
-
Supply and fix in replacement of Inrus protection relay wide range,4BI + 6BO,IEC 103/MODBUS on RS 485 port,Non draw out,24-250 VDC/AC universal voltage.CT secondary 1A & 5 A Universal,wide range complete all as specified and directed.
2
-
-
Labour for Disconnecting,repairing,servicing of existing HT 11 KV/33 KV VCBs/SF6 breakers of any make from housing and cleaning, rubbing and overhauling the mechanical parts and servicing of 11 KV indoor VCB upto 800 amp , checking of quality of vaccum interrupter, insulation resistances, static contact resistance, testing (IR value, Ratio test, Polarity test) and connection verification of 11 KV current transformer (Set of three) by PRIMARY INJECTION KIT, and testing and calibration of relay (set of two over current and one earth fault) by SECONDARY INJECTION KIT including all other functional tests of VCB, C&R panel and CTs, PTs,auxilary relay complete all as directed. NOTE: (i) Rate Included also for complete bus bar cleaniong and tightning,checking of bus bar insulation test,IR test with heat shrinkasble bus bar slive,IR test ,CRM test for busbar and breaker including testing of breaker IR testing,closing and opening time test coil ressitrance test,motor resistane test and submit the all final test reports ckeacking and replacement of rusted HT hardware nut and bolts (ii) Contractor should make his own arrangement of testing equipments and electric supply so required. A detailed test report should be submitted to Engg-in-charge.
(iii) All test should be carried out by authorised company service dealer with company othorised certificate of Individual.
(iv) Service charges of service engineer for attending servicing/overhauling of 11 KV vcb included in quated rates.
46
-
-
Labour for Power Transformer routine test ( regular at site)33/11 KV,3.15 MVA including removing of both side cable and refixing the same carried out folling test
IR Test,Ratoi test,Magnetic core balance test,open circuit test,vector group test,short circuit test,No load test,winding resistence test complete
Note : Test report mandatory for all test and submitted to Engr in charge is resposibility of contractor (ii) External Eletric supply and transport required for all above test is supplyed by contractor at his own arregement rate included in quited rate
4
-
-
Supply and fix inreplacement of DC Power pack ,input 230 Volt Ac and output 30 volt DC,SPD base,,continous load 100 VA,impulse load 450 volt for 240 MS,back up 20 minute complete all as specified and directred. Make Gogate Elerosystem /Allen Eletreicals and equivalent
4
-
-
Supplky and fixing CTTB (current transformer terminal block) 2. 5 Sqmm including control wiring 2.5 Sqmm suitable for 11 kv vcb complete all
10
-
-
Supply and fixing in replacement of PT fuses suitable for 11 KV,rating 3.15 Amps complete all as specified and directed.
15
-
-
Supply and fixing Hooter suitable for control relay panel of range 18 -90 volt AC/DC complete all as specified and directed.
1
-
-
Supply and fixing in replacement of breaker control switch four position suitable for 15 Amps complete all as specified and directed.
15
-
-
Suply and fixing in replacement of space heater 100/80 watt for VCBs 11 KV complete all as specified and directed.
5
-
-
s & F in replacemennt for resin cast type twin secondary current transformer of ratio 100-50/5-5A ,core 1:15 VA/Class – .5 and core 2: 15 VA/class .3P10,STC : 26.3 KA/1 SEC for protection and metering , conform IS – 2705 of 1992 complete all as directed. Make : Crompton/Kirloskar
1
-
-
Supply and fixing in replacement of 5 mm thick toughend arylic transferent door glass with gasket of suitable size existing size
5
-
-
Supply and fix in replacement of Auxilary contractor 2 No + 2 NC with Addon,30 volt DC,20-25 Amps Make :" L 7 T /ABB/ Siemens
7
-
-
Supply and fixing in replacement of Tripping/closing coil 11KV,30 volt Dc complete all as specified and directed. Make : crompton/kirloskar
4
-
-
Supply and fixing in replacement of Tripping/closing coil 33KV,30 volt DC Make : crompton/kirloskar
2
-
-
Supply and fixing in replacement of fuse base with carrier 20 Amp Make : CG
20
-
-
Supply and fixing in replacement of 32 pin plug and socket for CG breakercomplete all as specified and directed.
2
-
-
Supply and fixing in replacement of tripping half shaft for 11 KV CG VCB complete all as specified and directed.
3
-
-
Supply and fixing in replacement of closing half shaft for 11 KV CG VCB complete all as specified and directed.
3
-
-
Supply and fixing in replacemnt of Master trip relay ,30 volt DC CGL complete all as specified and directed.
3
-
-
Supply and fixing in replacement of big Gear Assembly for 11 kv VCB , Make - CG/Kirloskar
3
-
-
Supply and fixing in replacement of small gear assembly for 11 kv,VCB, Make- CG/Kirloskar
3
-
-
Supply and fix in replacement of warm wheel for 11 kv VCB full teeth compmete all as specified and directed. Make : CG
1
-
-
Supply and fix in replacement of motor cut off limit switch suitable for 11KV, VCB complete all as specified asnd diercted
2
-
-
Supply and fixing in replacement of micro switch assembly for vcb 11 kv, Make -Kirlosker/ CG
2
-
-
Supply and fix in replacement of Anti pumpiung device relay for 11 KV VCBs complete all as specified and directed.
1
-
-
Supply and fix in replacement of timer for motor protection range 0-25 Amps for 11 KV VCBs complete all as specified and directed.
1
-
-
Supply and fix in replacement of trip circuit healthy push butten with Normally open contact for 11 kv vcbs complete all as specified and directed.
10
-
-
Supply and fix in replacement of Announaciator for SF6 control and relay panel upto 12 window voltage range 18-90 volt complete all as specified and directed.
1
-
-
M & L for replacement of SF6 copper Armed cable 10 core,2.5 Sqmm complete all as specified and directed.
50
-
-
M&L for gas charging for breaker by using SF-6 gas including checking SF6 gas pipe line ,pole leakage and reparing and reffiling of gas complete all as specified
3
-
-
Supply and fix in repair of racket wheel assembly for SF6 breaker 33 kv
1
-
-
Supply and fix repair povel set assembly make as per existing site for sf6 breaker
1
-
-
Supply and fix in repair closing latch assembly
1
-
-
Supply and fix in repair of complete set O ring assembly
1
-
-
Supply and fix in repair of crank lever assembly
1
-
-
Supply and fix in repair of AVR relay for RTCC panel ,110V,Ac
1
-
-
Supply and fix in repair of tap position Indicator meter for RTCC panel
1
-
-
Servicing ,Testing of RTCC Panel including rewiring,relay setting,testing ,calibration and reconditioning complete all as specified and directed.
2
-
-
Labour only for dehydration filtration and cleaning of transformer oil of 33 KV / 11KV power transformer / distribution transformer / HT switchgear till achievement of die-electric-strength of strength should be not less than 40 KV for new insulating oil and 45 KV for existing oil at 2.5MM Gap all as specified and directed Note :(i) Toping of Transformer oil shall be measured and paid separately.
(ii) Transportation of Filtration vehical and required vehical mounted DG set for power supply during the filtration of transformer is responsibility of contractor and rate included in quaited rates.
8000
-
-
Supply only new insulating oil conforming to IS 335 for Power Transformer/MOCB etc all as specified and directed. Note : transfor oil shall be supply only in seailed barrel
600
-
-
Decanning the Power transformer oil from leaking transformer by opening the stop valve.Checking for leakages, arresting the leakages, replacing cork sheet gasket 5 mm thick,bushing,washer, HV/LV Road,tapchanger gasket, reassembling the transformer completely at nearest authorized workshope & refilling transformer oil, connecting HT / LT connection complete and back install at sub station 33/11 solapur & New KLP , all as directed.
NOTES: (i) Spares required shall be measured and paid separately under relevant. (ii) Topping of transformer oil will be measured and paid separately. (iii) The rate quoted includes HV/LV rod,Gasket, cork sheet,washers,tap changer gaskit etc. (iv) The rates also includes charging with and without load. (v) The rates includes transportation of transformer to workshop and after repairing installed back at site complete all as directed by Engr-in-charge (vi) Re-insulation & heating of LV/HV coil included in rate quoted
1
-
-
M&L for existing 33 KV / 800A GOD set, horizontal operation by replacing all stationary and moving contacts for all the three phases, rutsed nuts, bolts all as specified and directed
4
-
-
M&L for repair and servicing testing and recommissioning series reactor by replacing gasket set, insulating oil etc including painting by using two coats of synthtic enemel paints all as specified and directed
2
-
-
M & L for servicing testing of OLTC including opening top and bottom plate removing of oil and refiiling of oil and checking of all taps removing of uncv parts and replace it complete
Note: Spare parts and oil measured and paid separetly
1
-
-
Supply and fix in repalacement of resistance moving contact assembly for OLTC complete all as specified and directed.
1
-
-
Supply and fix in repalacement of main moving contact assembly for OLTC complete all as specified and directed.
1
-
-
Supply and fix in repalacement of contact for OLTC complete all as specified and directed.
20
-
-
Supply and fix in repalacement of transister register assembly for OLTC complete all as specified and directed.
1
-
-
Supply and fix in repalacement of local remote switch for OLTC complete all as specified and directed.
2
-
-
Supply and fix in repalacement of eletrical counter for OLTC complete all as specified and directed.
1
-
-
Supply and fix in repalacement of Directional selector switch OLTC complete all as specified and directed.
1
-
-
Supply and fix in repalacement of oil Sealed for OLTC complete all as specified and directed.
2
-
-
Supply and fix in repalacement of top let gasket & bottem let gasket assembly for OLTC complete all as specified and directed.
2
-
-
Supply and fix in repair Auto manual selector switch for OLTC comlete all as specified and directed.
2
-
-
Supply and fix in repair On /0ff switch for OLTC comlete all as specified and directed.
1
-
-
Supply and fix inrepair Lower/Raise/ACK push butten for OLTC complete all as specified and directed.
2
-
-
Supply and fix in repair Tap changer alarm hooter complete all as specified and directed.
1
-
-
Supply and fix inrepair mechanism stuck alarm hooter for OLTC complete all as specified and directed.
1
-
-
Supply and fix in repair Tap counter for OLTC complete all as specified and directed.
1
-
-
Supply and fix in repair Tap position Indicator for OLTC complete all as specified and directed.
1
-
-
Supply and fix in repair only starter, Three phase 4-10 AMps complete all as specified and directed.
1
-
-
Supply and fix in repair only spring charging motor gear box assembly 230 VAC, for VCB,11 KV Make - , Crompton/ABB/Siemens
1
-
-
Supply and fix in repair only control fuse links NS type 2A, 4A, 6A,10A,16A complete all as specified
140
-
-
Supply and fix in repair only busbar support insulator complete all a specified and directed.
8
-
-
S&F in repair of dropout (DO) fuse, explosion for outdoor, single pole mounted on and including 33000V insulator - 02 Nos and MS Channel with nuts, bolts and washer of capacity 100Amp all as specified and directed
3
-
-
S&F in repair of lightning arrestor, station class, metal oxide 33 KV class III IEC long duration, current impulse rating with pressure relief high suitable for 33 KV including reconnecting in 33 KV distribution circuit and testing all as specified and directed.
1
-
-
Supply and fixing in repair Marshiling box with terminal box including TB terminal for CT/PT connection for 33 KV VCB including complete wiring and testing complete all as specified and directed
3
-
-
Supply and fix in repair 33KV SF6 outdoor breaker TR-02 closing linkage assembly complete all as specified and directed.
1
-
-
Supply and fix in repair DP 10 Amps,10ka complete all as specified and directed.
10
-
-
M&L for painting to 33 KV substation outer fencing and 11 KV substation fencing of structure complete including channel, beams, angle bracket supports, clamps by using two coats of aluminium paint after scrapping out existing wornt out paint including square wire mesh all as specified and directed.
500
-
-
S& F in replacement sign boards for MES installations of size 1200x 900mm made out with angle iron 40x40x 6mm as framing covered one side with 2 mm thick aluminium sheet rivetting on frame covered with retro reflective sheet & 100mm high letters as diredcted. Th sign board to be fixed on 2 No. 40x40x6mm angle iron legs of upto 2 mtr long embedded in PCC(1:4:8) using 40mm graded stone aggregate including of necesary excavation complete at the installation etc complete all as specified and directed by Engr-in-charge Note : Information on sign board supplied by Engr in Charge
4
-
-
Painting of VCB Panel consist 6 nos of panel in one Job) outerside with power coating spray painting with instant dry type paint RL 7032 including covered panel assessories like Amp meter ,voltr meter ,relay,selector switch etc with transferent tape and removing after paint complete all as specified and directed.
2
-
-
Supply and fix in repair of epoxy paint for VCB breaker insulater complete all as specified
5
-
-
Supply and fixing in repair relay fixing plate including cutting,drlling,fixing etc plate ,size 200 x 200 mm with power coating RL 7032 complete all as specified and directed.
8
-
-
Supply and fixing in repair residual voltage transformer ,
VOLTAGE RATIO- 11KV/V3/110KV/V3/190 VOLT ,3 phase,50 HZ,complete set
Insulation level - L1 75,AC28/1.2 cont,1.9 for 30 sec
Burden - 50 VA sec,50 VA TER
Class - 1/3 P Make : Harshanil Eletric Pvt Ltd and Equivalent
1
-
-
Supply and fixing in replacement including testing of power factor capacitor set of 3 outdoor box type fixed on channel 11 kv of following specification
Capacitor unit :PMPO,3 Phase
Rated KVAR : 70
Rated KV : 6.7,50 Hz (for each)
Rated Current : 10.45 Amps,Temp Catagary : 50 degree centigrade,Insulation Level -28/75,Discharge time - 600 Second. Make :Madhav capacitors Pvt ltd and Equivalent
1
-
-
M & L for shifting of transformer of any capacity from two pole /fore pole structure with crane including dismentalling existing connection of transfomer and shifting it on plinth within 100 mtr area and reconection of transformer after shifting on the plinth with necessary connection and testing of survicable complete withoput any damage all as specified and directed by engr in charge .
Note : Any type of damage/lekage of tranformer oil during the shifting/transportation is repaired by contractor at his won payment without any claim
4
-
-
M &L for transformer plinth (of size 2000mm x 2000 mm x 1500 mm) including excavation in trenchs in any type of soil,PCC 1:4: 8 in foundation fly ash bricks machinaryin cement mortor1 : 6 ,filling with moorum inside the plinth and RCC 1:2:4 over plinth including 16 mm bar reainfrocement with center to centre distane 100mm and external surface of masonary shall be plasterd with cement morter 1:4 and painted with weather coat paint ( double coat paint ) of shade as directed by Engr In Charge complete all as specified and directed by Engineer- in- charge
2
-
-
Supply and fixing in replacement of synthetic insulating rubber mat tested for HT 11/22 KV with test certificate for installation of size 2m x1m x22 mm etc complete all as specified and directed by Engineer-in-Charge
13
-
-
Supply and laying of bricks surrounding the stone aggregate at sub station including necessary excavation,returning and removing complete all as specified and directed.
1
-
-
M&L Providing Pre cast RCC 1:1½:3 type A1 using 20 mm graded stone aggregates as in Cable Route Indicator of height 800 mm x width 300 mm x thickness 120 mm duly reinforced all as per details shown in drawing and having top circular section, provided with and including PCC 1:4:8 type D2 using 40 mm graded stone aggregates foundation of suitable size as directed and including engraving letters "MES 11 KV HT" on route indicator duly painted in synthetic enamel ( dark brown colour) paint, complete .
100
-
-
Supply and fixing in replacement of Indicating lamp with universal voltage with color caading ,Red ,Yellow ,blue,Amber, White ,Green
144
-
-
Supply & Fixing in replacement of Digital volt meter, Single phase
9
-
-
Supply & Fixing in replacement of Digital Ammeter meter,11/33 KV,control supply 230v AC
14
-
-
S & F replacement of HT bushing, porcelain vitreous brown body suitable for power traxsformer as per IS 3347.
4
-
-
M & L for replacement of breather assembly including silica gel complete suitable for power transformer existing at site complete all as specified anddirected.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%