Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Dec 2024
Closing Soon15 Jan 2025
Tender Amount₹ 79,50,000
Costs
EMD
₹ 1,44,250Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_689341_1Tender No
8068/CWE(NW)MUMBAI/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
SCHEDULE 'A' PART II
Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolley of rupturing capacity 250/350 MVA, 400/630/800/1200 Amps from location and repair /overhauling and carrying out with the following complete all as specified and directed by Engineer-in-Charge.
(Note: spare parts will be measured & paid seperately.)
(i) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly switch assembly and applying multi grease lubricant to function smoothly. (ii) Inspecting / overhauling of tripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.
(iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptors by carbon cleaner solution and applying dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.
(iv) Assembling all items/components parts to the respective position & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete.
10
-
-
... More
Material and labour for painting of HT VCB capacity 250/350MVA,11KV, 400/630/800/1200Amps, with one coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities for out side surface and inside surfaces of VCB and complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Material and labour for Opening the bus-bar chamber, CT chamber, PT Chamber and Meter chamber of HT 11KV, panel board and carrying out the following and all as directed and specified by Engineer-in-Charge. (Note: spare parts will be measured & paid seperately.) :-
(i) Inspecting/cleaning/overhauling of bus bar chamber by checking of bus bars, spout insulators, space heaters and removing dust with vacuum cleaner/Blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying STRIPPEX(A), STRIPPEX(B) and HT tape and testing with High Voltage(DC) and meggering before and after high voltage test complete.
(ii) Inspecting/cleaning/overhauling of CT/PT chamber by checking of Bus bars, spout insulators, space heaters and checking of wiring system and removing dust with vacuum cleaner/blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying anti tracking paint on CT's and insulators and HT Tape.
(iii) Inspecting/cleaning/overhauling metering chamber by checking of entire wiring system, all meters, selector switches, control fuses and removing dust with vacuum cleaner/blower and moisture by hot air blower and checking tightness of wiring system.
10
-
-
... More
M & L for overhauling, calibration and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load including testing complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Testing of primary injection by artificial load through CT’s, on each multiple setting of over current & earth fault relay, testing polarities, ammeter and selector switch and complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts, AC and replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechanical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed by Engineer-in-Charge.
Note : Spare parts and oil will be measured and paid seperately.
4
-
-
... More
Testing of dielectric strength of transformer oil of indoor type transformer, 11KV/433 volt, filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to above 40 KV for 1 minute including new transformer oil for toping up & testing after filtration complete all as specified and directed by Engineer-in-Charge.
(Note: Transformer oil will be measured & paid seperately.)
4400
-
-
... More
Supply only transformer oil with 50KV di-electric strength for topping up and replacement of old/burnt transformer oil complete all as specified and directed by Engineer-in-Charge.
1200
-
-
... More
Supply and fixing in repair of breather with 500 Grams silica gel of indoor type transformer for 1600KVA, complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Material and labour for preparation of old painted surfaces of Transformer 1600KVA ,11KV/440Volt capacity, indoor type with scrapers, cleaning all dust etc, filling of cavities and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer with spray painting complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Material and labour for disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer 1600KVA ,11KV/440Volt, top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for attending leakage problem with replacement of oil seal, all gaskets, thermometer(oil temperature gauge) and reassembling complete all as directed.(Note : New Transformer oil and spare parts will be measured and paid separately excluding oil seal and thermometer i.e oil temperature gauge)
4
-
-
... More
S & F in repairs copper alloy stud with nut, bolts, washers and bushing with oil seals on HT side of Transformer 1600KVA ,11KV/ 440Volt complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
S & F in repairs copper alloy stud with nut, bolts, washers and bushing with oil seals on LT side of Transformer 1600KVA ,11KV/ 440Volt complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Supply and fixing in repair following spare parts suitable for GEC Alsthan make HT VCB, 11 KV, 630/ 800/ 1000/ 1200 Amps indoor type complete all as specified and directed by Engineer-in-Charge.
-
-
-
... More
Opening / Closing Push Button Assembly
2
-
-
... More
Motor Charging mechanism gear box
1
-
-
... More
Limit Switches
1
-
-
... More
Closing Coil Assembly
1
-
-
... More
Tripping Coil assembly
1
-
-
... More
Spring Charging Motor
1
-
-
... More
Auxiliary Switch with link
1
-
-
... More
Spring return latch
1
-
-
... More
Vaccum Interupter assembly
2
-
-
... More
Spout Insulator assembly (3Phase) feeder side
2
-
-
... More
Spout Insulator assembly (3Phase) Bus bar side
2
-
-
... More
Potential Transformer,11KV/110Volt/Route3,100VA burden trolley mounted with HRC Fuse
2
-
-
... More
Current Transformers,50-30,5+5Amps, Class1 and 5p10,15VA,18.3kA/3Sec
3
-
-
... More
TNC Switch
2
-
-
... More
PF meters digital type 96x96mm
4
-
-
... More
Indicating Lamps LED type
10
-
-
... More
Supply & fixing in repair strip type heater 80 watt with control wiring suitable for indoor VCB,11 KV switch gear Panel board complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Dismantling Air Circuit Breaker 4pole/3pole, 630/ 800/ 1200/ 2500 Amps, 415 Volts, draw out/ fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & applying multi grease for mechnical parts, cleaning and inspecting male and female contacts and applying dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and directed by Engineer-in-Charge.
(Note : Spare parts will be measured and paid separately)
10
-
-
... More
Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric panels Indoor type of each Transformer by obtaining permission for shut down from appropriate authority including checking loose connections and tight connection and cleaning inside/out side all connection, replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petroleum jelly on the contactors, providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it serviceable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed by Engineer-in-Charge. (Note: The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt ACB/ MCB/MCCB/Voltmeter/Amperemeter/CT/LED lamps of any type and description etc and refixing the same, which shall be measured and paid as supply only vide relevent items of this schedule.) (i) Cleaning inside the panel and all incoming and out going feeders i.e including MCCB/SFU/Changeover switches/Contactors/ ACB's thoroughly with help of Vaccum Cleaner.
(ii) Checking the loose connections of incoming and out going feeders and rectififying the same with help of new GI nut bolts and washers
(iii) Replacing the burnt out color coated PVC Sleeve of main and fedders bus bar with appropriate size of New PVC heat shrinkable sleeves -01Job
(iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/Hrc Fuses-01Job. (Note: New items will be measured and paid separatly)
(v) Replacing burnt out control wiring of Ammeter/Voltmeter/Indicating lamps and CT'swith 2.5/1.5Sqmm copper single core,1100V grade copper conductor cable- 01Job
(vi) Replacing Burnt out Bus Bar of incomming and out going feeders with appropriete size of new bus bar (Copper/Aluminum) -01Job ( Note : Bus Bar will measured and paid separately).
(vi) Replacing Burnt out Insulators of incoming and outgoing feeders with appropriate size of new Insulators -01Job ( Note : Insulators shall be measured and paid separately)
(vii) Spray Painting of Panel Board with one coat of synthetic enamel paint.
8
-
-
... More
Supply and fixing Aluminium Bus Bar strips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and directed by Engineer-in-Charge.
Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs.
(b) Overall length of the strip shall be measured and paid after necessary conversion into weight.
(c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account.
(d) Rate of Bolts, Nuts etc shall be included in quoted rate.
8
-
-
... More
Supply and fixing Copper Bus Bar stips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and directed by Engineer-in-Charge.
Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs.
(b) Overall length of the strip shall be measured and paid after necessary conversion into weight.
(c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account.
(d) Rate of Bolts, Nuts etc shall be included in quoted rate.
8
-
-
... More
Supply and fixing suitable type and size FRP / DMC bus bar support insulator (Bridge Insulator) for fixing the extended aluminium/ copper bus bars, for cable terminations, duly fixed in the body of the panel board including galvanized steel bolts, nuts, washers etc.and necessary drillings, in the panel body complete all as specified and directed by Engineer-in-Charge.
6
-
-
... More
Material and labour for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
Supply and fixing cable jointing kit Straight Through Heat shrink type Joint for 11KV grade cable complete with Jointing material and accessories suitable for 3 core XLPE armoured, aluminum conductor cable of size 120 to 185 sq mm complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply and fixing cable jointing kit Straight Through Heat shrink type Joint for 11KV grade cable complete with Jointing material and accessories suitable for 3 core XLPE armoured, aluminum conductor cable of size 240 to 300 sq mm complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply and fix cable jointing kit, End Termination Joint indoor for 11KV grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3 core XLPE armoured, aluminum conductor cable of size 120 to 185 sq mm complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
Supply and fix cable jointing kit, End Termination Joint indoor for 11KV grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3 core XLPE armoured, aluminum conductor cable of size 240 to 300 sq mm x 3 core complete all as specified and directed by Engineer-in-Charge
2
-
-
... More
Supply, laying, commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 10 Sqmm x 2 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles including taking out old u/s damaged cables complete all as specified and directed by Engineer-in-Charge.
450
-
-
... More
- Ditto- all as per Item No 43.00 above but of size 6 Sqmm x 4 core.
200
-
-
... More
- Ditto- all as per Item No 43.00 above but of size 10 Sqmm x 4 core
200
-
-
... More
- Ditto- all as per Item No 43.00 above but of size 16 Sqmm x 4 core
500
-
-
... More
- Ditto- all as per Item No 43.00 above but of size 25 Sqmm x 4 core
250
-
-
... More
- Ditto- all as per Item No 43.00 above but of size 35 Sqmm x 4 core
200
-
-
... More
- Ditto- all as per Item No 43.00 above but of size 50 Sqmm x 3.5 core
225
-
-
... More
- Ditto- all as per Item No 43.00 above but of size 70 Sqmm x 3.5 core
200
-
-
... More
- Ditto- all as per Item No 43.00 above but of size 95 Sqmm x 3.5 core
210
-
-
... More
- Ditto- all as per Item No 43.00 above but of size 120 Sqmm x 3.5 core
100
-
-
... More
- Ditto- all as per Item No 43.00 above but of size 150 Sqmm x 3.5 core
183
-
-
... More
- Ditto- all as per Item No 43.00 above but of size 185 Sqmm x 3.5 core
100
-
-
... More
- Ditto- all as per Item No 43.00 above but of size 240 Sqmm x 3.5 core
50
-
-
... More
- Ditto- all as per Item No 43.00 above but of size 300 Sqmm x 3.5 core
50
-
-
... More
Taking out carefully old XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, from the trenches/ pipes/ walls and keeping safely for reuse at site, the cross sectional area of 10 to 50 Sqmm x 3.5 core complete all as specified and directed by Engineer-in-Charge.
200
-
-
... More
Laying only old XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles the crossectional area 10 to 50 Sqmm x 3.5 core complete all as specified and directed by Engineer-in-Charge. Note- Cable taken out Sch "A" srl item no 57.00 to be re-used.
200
-
-
... More
Excavation in trenches not exc 1.5 mtr wide and not exc.1.5 mtr in depth for laying of cables etc. and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Note : Rate includes removing of paver blocks carefully, stack properly and refixing after laying of cables .
196
-
-
... More
Returning filling in , including spreading, leveling, watering and well ramming in layers not exc 25 cmm in soil.
115
-
-
... More
Removing surplus excavated material outside MoD land complete all as specified and directed by Engineer-in-Charge.
Note: The place of disposal shall be find out by the contractor.
75
-
-
... More
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I .
Note :- Only compacted thickness of sand will be measured and paid.
62
-
-
... More
Fixing only machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 100 mm thickness M-50 Grade not less than 0.45 mtr wide for repairing road cutting / footpath carried out under Sch "A" srl item No -57.00.
10
-
-
... More
Supply and laying un-reinforced precast concrete cable cover class LV type 1 flat of size 250mm x 150 mm x 40 mm complete all as specified and directed by Engineer-in-Charge
4000
-
-
... More
Cutting existing road surfaces or hard standing 0.45 mtr depth (22mm thick comprising bituminuous topping) for laying of pipes/cables and making good disturbed surfaces to match with existing surfaces complete all as specified and directed by Engineer-in-Charge
20
-
-
... More
Material & labour for PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) for road/Hard standing cutting complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
Material & labour for PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in coping for steel pole including necessary formwork complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
S & F in repairs 100mm bore High density polyethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe for cable protection laid in trenches for crossing road or above ground surface complete all as specified.
40
-
-
... More
- Ditto- all as per Item No-68.00 above but 50mm bore.
30
-
-
... More
- Ditto- all as per Item No-68.00 above but 25mm bore.
30
-
-
... More
Material & labour for GI pipe ,light grade 40mm bore for cable protection laid in trenches for crossing road or above ground surface complete all as specified.
20
-
-
... More
Supply and fixing Exhaust fan, steel body AC single phase, 230volts, 50Hz of size 200mm sweep with blades, frames and louvers including connecting up with three core flexible copper conductor cable of suitable size including one 6 Amps 1 way switch controlled by fan point and using digital Timer switch 110-240 V, AC, 50/ 60HZ tolerance -20% to +10% contact 16 A (NO) & 5A (NC) @ 240 VAC/24 VDC model digital crono times setting by position coordinates Performance testing with necessary time adjustment of digital timer for successful operation at the time of users requirement complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Cutting hole in existing LT panel board 3mm thick suitable for fixing 200mm sweep exhaust fan and making good the hole using proper gasket work and surface finish in side and outside the hole as per site requirement complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
Supply and fixing ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply and fixing ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 250 Amps complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
M & L for earthing complete with G .l earth plate electrode 60cm x 60 cm x 6.3 mm thick burried directly in ground vertically (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50m, including PCC chamber in PCC (1 : 2 : 4) type B1 (using 20 mm graded stone aggregate), precast RCC (1: 2 :4) type B1 (using 20 mm graded stone aggregate) as in eartpit cover reinforced with XPM jali not less than 4 Kg per Sqm as with handle , watering arrangement with funnel internally secured with wire mesh, 20 mm bore medium grade GI pipe for watering, 40 mm bore light grade Gl pipe for lead protection including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified and indicated including testing on completion as directed by Engineer-in-Charge.
4
-
-
... More
Material & labour for Galvanised iron strip 32 x 6mm burried in ground or fixed on walls/floor with suitable saddles and screws beyond 7.5mtr of earth lead connecting with test point after taking out old/unserviceable one complete all as specified and directed by Engineer-in-Charge.
40
-
-
... More
Supply & fixing test point terminal block for connecting the earth pit and down conductor or Aluminium strip, made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw after taking out old/unserviceable one complete all as specified and directed by Engineer-in-Charge.
6
-
-
... More
S & F in repairs Solar LED standloane street light 45 Watts, system volt -24 Volt, Lumens- 4725Lumen, Maximum power point tracking control with in built SCC, SPV Panel - 200wp (100 x 2 Nos), Low maintenance lead acid tubular battery-120AH (2 x60AH), Hot Dip Galvanized tubular pole length - 6 mtr above ground level with base plate and clamps including all accessories, Pole/box with clamp duly painted with one coat of red oxide and two coats of Synthetic enamel paint blue/silver colour including taking down existing battery box complete all as specified.
Note:- Earth work and PCC foundation shall be measured and paid separately.
2
-
-
... More
S & F in repairs Mild steel solar street light battery box 5mm to 10mm thickness, surface finished, rectangular shape, single phase, weight - upto10 Kgs, fixed to pole with MS clamp made out of MS flat 25mm x 5 mm duly painted with one coat of red oxide and two coats of enamel paint blue/silver colour to MS box and MS clamp including taking down existing battery box complete all as specified.
5
-
-
... More
Taking down carefully street light/ flood light/ post top/High mast light fittings for repair/replacement of any capacity from 40-200 W and refixing the same after all repair work complete all as specified and directed by Engr-in-charge.
Note: Spares shall be measured and paid separately.
130
-
-
... More
Supply only LED driver of 40/45 W LED Street light/ Post top/ Flood light fitting.
50
-
-
... More
Supply only LED driver of 60/72 W LED Street light/Flood light fitting.
25
-
-
... More
Supply only LED driver of 90 W LED Street light/Flood light fitting.
20
-
-
... More
Supply only LED driver of 100 W LED Flood light fitting.
20
-
-
... More
Supply only LED driver of 160 W LED Flood light fitting.
10
-
-
... More
Supply only LED driver of 200 W LED Flood light fitting.
5
-
-
... More
S&F in repairs PVC insulated sheathed multistranded flexible copper conductor cable of size 2.5 sqmm x 3 core, drawn through existing conduit / pipe from junction box to fitting complete including taking down old unsv cable all as specified.
100
-
-
... More
S & F in repairs Solar street light Hot Dip Galvanized tubular poles 80mm dia complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified (7.5 meter Long) and applying one coat of steel primer and two coat of aluminium paint and marking pole ser number as per existing number including taking out old corroded/broken pole by cutting or digging complete all as specified and directed by Engineer -in-Charge. Note:- Earth work and PCC foundation shall be measured and paid separately.
10
-
-
... More
S & F GI tubular poles 50mm dia, 5 meter Long for Post top lantern ,applying two coat of synthetic enamel paint (block colour) over a coat of red oxide zinc chrome primer, marking pole ser number as per existing number including taking out old corroded/broken pole by cutting or digging complete all as specified and directed by Engineer -in-Charge. Note:- Earth work and PCC foundation shall be measured and paid separately.
20
-
-
... More
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete for embedding steel pole complete all as specified.
2
-
-
... More
M&L for 8.5 meter Long Steel tubular swaged poles type 410 SP-22 complete with cast iron base plate, final taper plug, bolts, nuts & scews as specified and applying one coat of red oxide zinc chrome primer and two coats of aluminium paint and writing pole ser number as per existing number including taking out old unserviceable/broken pole by cutting or digging complete all as specified and directed.
1
-
-
... More
S&F in repairs street light bracket bend to shape made as required of 40mm bore, 1 mtr long GI pipe light grade fixed to pole/ Wall with flat iron clamp of size 40mm x 6mm two numbers with the help of nuts and bolts for fixing of street light fitting complete all as specified and as directed.
10
-
-
... More
M&L Mild steel angle cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated and including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer (for supporting frame for flood light fitting) complete all as specified.
0.5
-
-
... More
M & L for scraping out old paint from Steel/HDG tubular poles more than 7.5 mtr length above ground level including street light arms and applying two coats of synthetic enamel paint of any tint over a coat of red oxide zinc chrome primer and writing pole numbers serially in 60 mm circle yellow base sticker and pole serial no written with radium letter in white colour, 150 cm above benching of pole complete all as directed by Engineer-in-Charge.
100
-
-
... More
Supply and fixing in repairs PVC insulated, stranded copper conductor cable of size 2 x 2.5 Sqmm + 1 x 1.5 Sqmm connecting from FRP type looping box to street light fitting connector, passing through steel tubular pole complete all as specified and directed.
150
-
-
... More
S & F in repairs junction box made from FRP sheet factory fabricated of size 300x200x110 mm including connector blocks four way having suitable size bolt to connect upto 35 sqmm x 3.5 core cable two Nos with the help of suitable copper gland, thimble nuts, washers supports by clamps made out of aluminium flat not less than 25 mm x 3mm with suitable size nuts, bolts and washers inside and outside looping box including fixing with electric pole complete as directed.
40
-
-
... More
S&F in repairs MCB TPN 32 Amp 10 kA, 415 V, 50 Hz, AC ' C " curve complete all as specified.
4
-
-
... More
S&F in repairs MCB TPN 63 Amp 10 kA, 415 V, 50 Hz, AC ' C " curve complete all as specified.
2
-
-
... More
S & F in repairs Timer switch 3 phase, 63 Amps capacity 01 No including power contactor nominal rating 25 A- 02 No with all accessories suitable for existing complete all as specified.
2
-
-
... More
Supply and fixing in repairs LED Flood light fitting 150 watts with secondary optics made in pressure die-cast housing and heat sink in aluminium xtrusion with IP66,having not less than 110 lumen per watt complete all as specified and directed .
18
-
-
... More
Supply and fixing in repairs LED street light fitting 120 watts with secondary optics made in pressure die-cast housing and heat sink in aluminium xtrusion with IP66, having not less than 110 lumen per watt complete all as specified and directed .
10
-
-
... More
Supply and fixing in repairs LED street light fitting 70 watts with secondary optics made in pressure die-cast housing and heat sink in aluminium xtrusion with IP66, having not less than 110 lumen per watt complete all as specified and directed .
20
-
-
... More
S & F in repairs LED Post top lantern 40 watts made in cast aluminium with decorative opal polycarbonate diffuser with IP65 protection, having not less than 110 lumen per watt complete all as specified and directed .
16
-
-
... More
Taking down old unserviceable Post top light fitting of any make/wattage and S & F in LED Post top lantern 25 watt made in cast aluminium with decorative clear opal acrylic diffuser with IP65 protection, complete all as specified and directed.
20
-
-
... More
S & F in repairs LED Post top lantern 45 watts made in cast aluminium with innovative glare free indirect lighting distribution and IP65 protection, having not less than 110 lumen per watt complete all as specified and directed .
10
-
-
... More
S & F in repairs 9 watt LED Bollard light fitting, watt offers a high level of durability with high impact resistance, easy to install, comes with ingress protection and provides compartable soft lighting having not less than 110 lumen per watt complete all as specified and directed .
20
-
-
... More
S&F in replairs MCCB TP 25 to 100 Amp 16 kA, 415 V, 50 Hz, AC complete all as specified & directed.
1
-
-
... More
S&F in repairs MCCB TP 125 Amp 16 kA, 415 V, 50 Hz, AC complete all as specified & directed.
1
-
-
... More
S&F in repairs MCCB TP 200 Amp 36 kA, 415 V, 50 Hz, AC complete all as specified & directed.
1
-
-
... More
S&F in repairs MCCB TPN 100 Amp 16 kA, 415 V, 50 Hz, AC complete all as specified & directed.
1
-
-
... More
S&F in replairs MCCB TPN 250 Amp 36 kA, 415 V, 50 Hz, AC complete all as specified & directed.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%