Military Engineer Services Tender
... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Aug 2024
Closing Date28 Sep 2024
Tender Amount₹ 30,00,000
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_669506_1Bid Award Id
ViewTender No
8531 REPAIRS/ REPLACEMENT/ MAINT SERVICING TO COOLING APPLIANCES LIKE Acs, AIR CURTAINS, WATER COOLETender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S & F as in repairs of Running capacitor as per existing MFD and type for window / split AC of capacity 1.5/2/2.5/3 ton as per exiting type Complete all and as specified and directed by Engineer-in-Charge.
50
-
-
... More
S & F as in repairs of Starting capacitor as per existing MFD for window / split /Cassete AC of capacity 1.5/2/2.5/3 ton Complete all as as per exiting type and specified and directed by Engineer-in-Charge.
45
-
-
... More
S & F as in repairs of Relay for window / split/Cassete AC of capacity 1.5/2/2.5/3 ton Complete as per exiting type and capacity all as specified and directed by Engineer-in-Charge.
50
-
-
... More
S & F as in repairs of Thermostat switch/sensor for window / split AC of capacity 1.5/2/2.5/3 ton Make Indfass Complete as per exiting type and as specified and directed by Engineer-in-Charge.
40
-
-
... More
S & F as in repairs of Condenser fan blade for spilt/Cassete Type A.C Cap 1.5/2/2.5/3 as per existing shape and size Complete all as specified and directed by Engineer-in-Charge.
20
-
-
... More
M&L for testing and repairing for replacement of old wornout/burnt wiring window AC as per existing type of capacity and length complete all as directed
20
-
-
... More
M&L for testing and repairing for replacement of old wornout/burnt wiring Split AC as per existing type of capacity and length complete all as directed
35
-
-
... More
Supply only Remote control for split AC Cap 1.5/2/2.5/3 Ton of any make as per site requirement Complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
M & L, testing and commissioning of Main printed circuit board (PCB) with electric accessories and sensors suitable for split AC capacity 1.5/2Ton Complete all as specified and directed by Engineer-in-Charge.
40
-
-
... More
M & L, testing and commissioning of Main printed circuit board (PCB) with electric accessories and sensors suitable for split /Cassete AC capacity 2.5/3 Ton Complete all as specified and directed by Engineer-in-Charge.
20
-
-
... More
M & L for Platic louvers for (Front panel) for Window AC 1.5/2 Ton as per existing at site Complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
M & L for Selector switch for fan/cooling of Window AC 1.5/2 Ton Complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
Supply only Suction and discharge valve set for Split /Cassete AC 1.5/2/2.5/3 Ton capacity of any make as per exisiting Complete all as specified and directed by Engineer-in-Charge.
60
-
-
... More
Supply and fix as in repairs service valve/Flair Nut of 1/2 inch all as per sample approved by Engr-in-charge.
30
-
-
... More
Supply and fix as in repairs service valve/ Flair Nut of 1/4 inch all as per sample approved by Engr-in-charge.
40
-
-
... More
Taking down carefully old unserviceable, burnt out sealed unit compressor from Window/split/casette type AC any type and size by means of unscrewing foundation nut bolts, disconnecting from suction & discharge side mechanically & electrically, of any make and keeping a side for further disposal as directed by Engr-in-Charge for the following :-
23
-
-
... More
Supply, fixing, testing and commessioning of AC sealed unit compressor of 2 Ton Capacity with including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification (caplary tube etc ) & Charging of Gas F-22/R-134A all as directed by EIC.
10
-
-
... More
All as per item No. 20 above but Air Conditioner of capacity 1.5 Ton
8
-
-
... More
All as per item No. 20 above but Air Conditioner of capacity 2.5/3 Ton
5
-
-
... More
Taking down carefully old unserviceable, burnt out fan motor from Window/split/casette type AC any type and size by means of unscrewing foundation nut bolts, disconnecting from suction & discharge side mechanically & electrically, of any make and keeping a side for further disposal as directed by Engr-in-Charge for the following :-
15
-
-
... More
Supply, fixing, testing and commessioning of new blower fan motor unit of window /Split type AC 1.5/2 ton capacity as per existing type and model
10
-
-
... More
-Ditto- all as per item Ser No 24 above but for Split /Cassete type AC 2.5/3 ton capacity of any make and type
5
-
-
... More
Supply, fixing, testing and commessioning of blower fan motor unit after carefully disconnecting form mains and Taking out unserviceable swing fan motor of Split type AC upto to 3 ton capacity of any make and type from any location and supply, installing and testing of new swing fan motor as per existing capacity and model
15
-
-
... More
Taking down carefully old unserviceable, burnt out condenser coil from Window/split/casette type AC any type and size by means of unscrewing foundation nut bolts, disconnecting from suction & discharge side mechanically & electrically, of any make and keeping a side for further disposal as directed by Engr-in-Charge for the following :-
62
-
-
... More
Supply, fixing, testing and commessioning of new condenser coli of window Type AC Cap. 1.5 Ton/2 Ton of any make and type all as directed by Engr-in- Charge.
2
-
-
... More
-Ditto- all as per item Ser No 28 above but for split AC /Cassete type AC 1.5 TR of any make and type
30
-
-
... More
-Ditto- all as per item Ser No 28 above but for split AC /Cassete type AC 2 TR of any make and type
25
-
-
... More
-Ditto- all as per item Ser No 28 above but for split AC /Cassete type AC 2.5/3 TR of any make and type
5
-
-
... More
Taking down carefully old unserviceable, burnt out evaporator /cooling coil from Window/split/casette type AC any type and size by means of unscrewing foundation nut bolts, disconnecting from suction & discharge side mechanically & electrically, stroing of refrigerant, brazing, of any make and keeping a side for further disposal as directed by Engr-in-Charge for the following :-
48
-
-
... More
Supply, fixing, testing and commessioning of Evaporator /Cooling coil coil of window type AC of capacity 1.5 Ton /2 Ton all as per existing type /size existing make and size all as per specified and directed by Engineer-in-Charge.
4
-
-
... More
-Ditto- all as per item Ser No 33 above but for split /Cassete type AC 1.5/2 TR of any make and type
40
-
-
... More
-Ditto- all as per item Ser No 33 above but for split /Cassete type AC 2.5/3 TR of any make and type
4
-
-
... More
Material & Labour for painting the body of window type AC/Split type AC outer body unit capacity 1.5/2 TR of any make and capacity of colour as per existing.
20
-
-
... More
Taking down unserviceable copper pipe of size 1/4" and supply & fixing new copper pipe 1/4" complete including brazing, welding, but bolts and screws of reqd size complete all as directed by Engr-in-Charge
200
-
-
... More
Taking down unserviceable copper pipe of size 1/2" and supply & fixing new copper pipe 1/2" complete including brazing, welding, but bolts and screws of reqd size complete all as directed by Engr-in-Charge
170
-
-
... More
Taking down unserviceable copper pipe of size 3/8 and supply & fixing new copper pipe 1/2" complete including brazing, welding, but bolts and screws of reqd size complete all as directed by Engr-in-Charge
50
-
-
... More
Material & labour for detecting the leakages of gas of window AC capacity 1.5/2 TR from any location and rectified/stopped the leakages by gas welding or by any other manner and make it functionng as directed by Engr-in-Charge
10
-
-
... More
Material & labour for detecting the leakages of gas of split /Cassete type AC 1.5/2/2.5/3 TR from any location and rectified/stopped the leakages by gas welding or by any other manner and make it functionng as directed by Engr-in-Charge
50
-
-
... More
Material and labour for Charging of only Refrigerant Gas F-22/R-134a in window type /Split /CasseteType AC Unit of capacity 1.5 Ton including testing and commissioning complete in satisfactory working condition.
40
-
-
... More
Material and labour for Charging of only Refrigerant Gas F-22/R-134a in window type /Split /CasseteType AC Unit of capacity 2Ton including testing and commissioning complete in satisfactory working condition.
35
-
-
... More
Material and labour for Charging of only Refrigerant Gas F-22/R-134a in window type /Split /CasseteType AC Unit of capacity 2.5/3 Ton including testing and commissioning complete in satisfactory working condition.
30
-
-
... More
M & L for Charging of only Refrigerant Gas F-22/R-134a in Split /Cassete Type AC Unit of capacity 2.5 /3Ton including testing and commissioning complete in satisfactory working condition.
10
-
-
... More
Material and labour for taking down of split type AC any type and Capacity duly storing of its refrigerant, disconnecting its both the copper tubes from indoor and out door unit carefully, taking its inner and outer unit and refixing the same in other side of wall/location as directed by EIC , duly filling of make up refrigerant as per desired pressure, minor brazing/welding in copper tubing, making all elect connections as before and testing all as spd and direted by EIC
40
-
-
... More
Material and labour for taking down old UNSV AC Stand and refixing of new stand for outer unit of Split AC (set of 02) as per the existing size for split type AC 1.5/2/2.5/3TR Capacity duly fixing it on wall with nut,bolt and washer as per desired pressure, minor brazing/welding all as spd and direted by EIC
15
-
-
... More
Material and labour for taking down old UNSV insulation pipe of split AC from inlet and out let copper tubing by storing the Referigerant incl and after fixing of new insulation restore the referigerant as earlier by making connection as before all as spd and direted by EIC
40
-
-
... More
Supply and fixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete with all as spd and directed in EIC.
20
-
-
... More
Material and labour for sub main wiring with two single core PVC insulated unsheathed copper conductor cable 4 sqmm drawing in and existing PVC conduit along with one additional PVC wire of copper conductor of 2.5 sqmm for earth continuity conductor of any length and making good the disturbed surface complete all as specified and directed by EIC.
200
-
-
... More
M&L in replacement of air filter made out of nylon wire mesh moulded in plastic complete suitable for existing old filter's size and shape, as directed for 1.5/2 TR capacity of split type AC
35
-
-
... More
Removing of old UNSV outdoor unit and supply and fixing as in replacement new outdoor AC unit with one new out door unit of 2 TR capacity duly assembled the following items :- consisting a 2-ton split air conditioner (AC) outdoor unit, consisting of a Compressor 2 TR capacity, duly charged with refrigerant gas, Condenser Coil to dissipate the heat from the refrigerant into the outside air, a Fan and Motor matching the 2 TR capacity, a Expansion Valve of suitable size to match the 2 TR capacity, Refrigerant Lines to connect the indoor and outdoor units suitable for a 2 TR system, all compontent to be duly connect with each as a required manner along with Electric Panel and Wiring, Printed Circuit Board (PCB), Mounting Brackets and Hardware, Necessary material for securely fixing the unit, Drain Pipe of suitable capacity to carry away condensation,Insulation Material for refrigerant lines to ensure efficiency all control box and Relays for managing the operation of the outdoor unit, Vibration Absorbe to minimize noise and vibration ,the whole items to be protected and placed in a suitable size unit/outer cover complete all as spd and directed by EIC.
3
-
-
... More
Taking down for servicing of Door air courtain any type and size including cleaning of blower / fan motor, air filter, nozzle or air outlet, motor for powers the blower or fan, control panel, internal wiring and keeping the door curtain unit in satisfactory working condition including small nut bolts, washers complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares will be measured & paid separately under relevant items and Labour charges for fixing of defective spares shall deemed to be included in unit rate quoted.for this item
5
-
-
... More
M & L for testing and commissioning of Main printed circuit board (PCB) with electric accessories and sensors suitable for door air curtain any type and size Complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply, fixing, testing and commessioning of blower fan motor unit after carefully disconnecting form mains and Taking out unserviceable fan motor/ blower motor of door air curtain any type and size from any location and supply, installing and testing of new fan motor as per existing capacity and model
1
-
-
... More
Taking down for servicing of walk-in-cold room of any Capacity and make including cleaning of insulated panesl, compressor, evaporator, condenser unit, door , lighting , temperature control system such as thermostats , defrost system, drainage system and keeping the AC unit in satisfactory working condition including small nut bolts, washers complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares will be measured & paid separately under relevant items and Labour charges for fixing of defective spares shall deemed to be included in unit rate quoted.for this item
5
-
-
... More
Supply only Thermostat switch for walk in cold room system of any capacity Complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
Supply only Condenser fan blade for walk in cold room system of any capacity as per existing shape and size Complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
Supply only Copper filter double capillary pencil type for walk in cold room system of any capacity Complete all as specified and directed by Engineer-in-Charge.
3
-
-
... More
Supply only Wiring kit for walk in cold room system of any capacity Complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
Supply only Main printed circuit board (PCB) with electric accessories and sensors suitable for walk in cold room system of any capacity Complete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
Disconnecting from mains and Taking out existing unserviceable sealed unit from the walk in cold sotrage unit of capacity 2/2.5 TR , of any make any type from any location and Supply , Installing and testing of new sealed unit compressor with including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification (caplary tube etc ) & Charging of Gas F-22/R-134A and commisioning as directed by Engg-in-Charge , Note :- Transportation Charges From site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted.
2
-
-
... More
Disconnecting from mains and Taking out existing unserviceable sealed unit from the walk in cold sotrage unit of capacity 4 TR , of any make any type from any location and Supply , Installing and testing of new sealed unit compressor with including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification (caplary tube etc ) & Charging of Gas F-22/R-134A and commisioning as directed by Engg-in-Charge , Note :- Transportation Charges From site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted.
1
-
-
... More
S&F in replacement of indoor discharge fan with for walk-in cooler complete as per existing type of following size as directed by Enginner- in- charge:-
-
-
-
... More
Description all as per ser No 64 above but & size 10"
2
-
-
... More
Description all as per ser No 64 above but & Size 12"
2
-
-
... More
S&F in replacement of HP/LP cut off, KP-15 Make - Danfoss/Indfoss for Walk-in-Cooler of any type
3
-
-
... More
S & F in replacement of Digital Sub-zero thermostat suitable for the cold storage & programe the thermostat for auto cut-off including all wiring complete as directed
3
-
-
... More
Disconnecting form mains and Taking out unserviceable fan motor/ blower motor of Walk in cold storage unit any type and size from any location and supply, installing and testing it by new fan motor as per existing capacity and model
1
-
-
... More
Disconnecting from mains and Taking out unserviceable condenser coil of Walk in cold storage unit any type and size from any location and supply, installing and testing it by new condneser coil as per existing capacity and make as directed by Engr-in- Charge.
1
-
-
... More
Supply and fixing in replacement of Evaporator /Cooling coil of Walk in cold storage unit any type and size from any location all as directed by Engr-in- Charge.
2
-
-
... More
Material & labour for detecting the leakages of gas of Walk in cold storage unit any type and size from any location and rectified/stopped the leakages by gas welding or by any other manner and make it functionng as directed by Engr-in-Charge
3
-
-
... More
Charging only Refrigerant Gas F-22/R-134a in Walk in cold storage unit any type and size from any location of capacity 2/2.5 Ton including testing and commissioning complete in satisfactory working condition.
3
-
-
... More
Removing after disconnecting all electric and refrigerent connection of old and UNSV wall mounted blower unit/fan coil unit and supply fixing , testing and commissioning of new wall mounted blower unit/fan coil unit of capacity 2 TR split AC, comprising the following :- Evaporator Coil ,Blower/Fan, Air Filter, Thermostat, Swing Motor to Controls the direction of the airflow,Electric Control Panel and Wiring, Display Panel Showing the operating status and settings, Control Box and Relays for managing the operation of the indoor unit, Insulation Material for refrigerant lines to ensure efficiency, Copper Tubing to Connects the indoor unit to the outdoor unit, Drain Pan and Pipe, Mounting Brackets and Hardware for necessary for securely fixing the unit the all accessories to be mounted and connected properly in a suitable size AC Indoor unit casing complete all as spd and directed by EIC.
3
-
-
... More
Disconnecting from mains and Taking down for servicing of Refrigerator/Deep freezer of Capacity 165 to 310 Ltrs including detecting the leakage of gas and refilling, cleaning of cooling coil, condenser, compressors, with vacuum cleaner OR cleaning solution including checking the servicibility of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition all as specified and as directed by Engineer-in-Charge.
Note :- 1. Replacement of defective spares for refrigerator /deep freezer will be measured & paid separately under relevant items and Labour charges for fixing of defective spare parts shall deemed to be included in unit rate quoted of for this item.
50
-
-
... More
Supply only Thermostat switch used with refrigerator/deepfreezer with Knob
10
-
-
... More
Supply only Starting relay 1/6 H.P. Open type used with refrigerator/deepfreezer with O.L.P.
10
-
-
... More
Supply only Starting relay 1/8 H.P. open type used with refrigerator/deepfreezer with O.L.P.
8
-
-
... More
Supply only copper filter single capillary pencil type used with refrigerator/deepfreezer.
12
-
-
... More
Supply only Door Lock for refrigerator 200to 310 ltrs
2
-
-
... More
Supply only Door switch for refrigerator 200 to 310 ltrs
3
-
-
... More
Supply only Interior light fittings with bulb used with refrigerator/deepfreezer.
10
-
-
... More
Supply only Door handle suitable for 200 to 310 Ltrs used with refrigerator/deepfreezer.
3
-
-
... More
Supply only compartment Glass used with refrigerator/deepfreezer.
5
-
-
... More
Disconnecting from mains and taking down the unserviceable compressor sealed unit of Refrigerator of any make and type and providing and fixing New Compressor suitable for 165 to 310 Ltr Refrigerator/deefreezer & testing and charging of the refrigent gas F-22 , R-134A and all other copper tubes, capillary and filter and put in working condition all as directed by Engineer-in-Charge. Note :- The Unit Rate quoted by the Contr shall include cleaning of condenser, Nuts & bolts and making necessary connection and testing complete.
5
-
-
... More
Material and labour for Charging only of gas refrigerant F 22 R-134A after detecting or rectify the leakages including cutting welding for Deepfreezer & Refrigerant capacity 165 Ltrs to 310 Ltrs of any Make complete all as specified and directed by Engr-in-charge.
20
-
-
... More
Supply and Fixing Voltage Stablizer for automatic operation single Phase naturally air cooled indoor type and design and input variation between 170 volt to 250 volt with output voltage stablized at 230volt with accuracy +/- 2.5% and of capacity 4 KVA complete , V Guard VG 400 or equvilent all as specified and as directed
5
-
-
... More
Supply and Fixing Voltage Stablizer for automatic operation single Phase naturally air cooled indoor type and design and input variation between 170 volt to 250 volt with output voltage stablized at 230volt with accuracy +/- 2.5% and of capacity 5 KVA complete , V Guard VG 500 or equvilent all as specified and as directed
5
-
-
... More
Disconnecting from mains and Taking down for servicing of Water Cooler of Capacity upto 150 Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the servicibility of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition all as specified and as directed by Engineer-in-Charge.
Note :- 1. Replacement of defective spares will be measured & paid separately under relevant items and Labour charges for fixing of defective spare partsshall deemed to be included in unit rate quoted for this item.
50
-
-
... More
Supply only Over load protect device for 40 to 150 Lts Cap. Water cooler
10
-
-
... More
Supply only Starting relay open type/Box type suitable for 40 to 150 Ltr water cooler
12
-
-
... More
Supply only Starting Capacitor 80-100 MFD for Water cooler .
10
-
-
... More
Supply only Running Capacitor 25 MFD for water cooler.
8
-
-
... More
Supply only Drain Hose pipe 40mm for water cooler.
20
-
-
... More
Supply only Condenser fan blade duly match with the existing system for fan Motor 1/10/ 1/16 HP for water cooler.
5
-
-
... More
Supply only Copper filter pencil type single / Double Capillary for water cooler.
7
-
-
... More
Supply only Self closing/pushtaps CP for water cooler Cap 40 to 150 Ltr
3
-
-
... More
Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from Water Cooler storage type capacity 40 to 150 Lts from any location and supply and installing it by the company made new sealed unit compressor of similar cap, cleaning of condenser by machine doing vacum the fully system and supply and charging of oil and gas and other necessary lubricants including reconnecting the electric and water connections & testing as directed by Engr-in-charge.
4
-
-
... More
Disconnecting the electric mains and Taking out unserviceable condenser fan motor 1/10, 1/16 HP from water cooler cap.40 to 150 Ltr and supply and replace with new motor single phase AC 220 V of same Cap including reconnecting the electric connections and testing . complete all as specified and directed by Engineer-in-Charge.
5
-
-
... More
Disconnecitng the mains and Taking out the unserviceable condenser coil fins type and S&F new condenser coil fins type as per existing size & patterns for Water Coolers 40 to 150 Ltrs Cap.
10
-
-
... More
Dismantling the evaporator/cooling coil of water cooler capacity 40 to 150 Ltrs, checking the leakages of gas and rectify the leakages by gas welding or as other manner and refixing complete all as specified and directed by Engineer-in-Charge.
8
-
-
... More
Material and labour for Charging only of Gas F-22/R134a for the water cooler Cap. 40 to 150 ltrs including testing and satisfactory commissioning
20
-
-
... More
Taking out the Water Cooler Tank from water cooler 40 to 150 ltrs cap. & repair the tank with brazing welding etc to stop the leakage of tank incl provn the insulating material as per existing type and size etc and repair to cooling coil and refixing as per original position & testing and commissioning
1
-
-
... More
Cleaning & removing the existing paint of Water Coolers Cap. 40 Ltrs by rubbing & preparing the surface smooth & applying one coat of primer and two coats of synthetic enamel paint by spray gun of colour as approved by E-in-Charge.
2
-
-
... More
M & L for repair of Top door made out of stainless steel with the existing guage sheet with handle and locking arrangement with double keys including door gasket and recommended insulation material and PVC inner sheet of suitable thickness for 40 to 150 Ltr capacity water cooler as per eixsiting size and shape, welding work nuts bolts & washerscomplete all as specified and directed by Engineer-in-Charge.
2
-
-
... More
Supply and Fixing of PVC connections 15 mm dia bore with PTMT nuts of length 600 mm including taking down the unserviceable PVC connections.
9
-
-
... More
Supply and Fixing Stop vlave cast copper alloy screw down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15 mm dia bore including taking down old unsv /rusted stop valve of any size/make complete all as specified and directed by Engr-in-charge.
10
-
-
... More
M&L for removing of old unserviceable stabilizer of capacity upto 3 KVA from the site, transporting it to the workshop, replacement of unserviceable spares such as control transformer, main transformer, voltmeter, relay, control board, etc as required and getting back the stabilizer at site and fiixing at the same position and checking it for its workablility as specified and directed
20
-
-
... More
M&L for removing of old unserviceable stabilizer of capacity 4/5 KVA from the site, transporting it to the workshop, replacement of unserviceable spares such as control transformer, main transformer, voltmeter, relay, control board, etc as required and getting back the stabilizer at site and fiixing at the same position and checking it for its workablility as specified and directed
30
-
-
... More
Routine maintenance services of central air conditioning plant of any capacity by checking and cleaning Air filters, adust thermostat settings, tighten of all electric connection, check and cleanning of condensate drain blockage, monitoring of refrigerant levels and check of leaks, clean evoporaor and condenser coils, inspect belts and pulley for wear and proper tension and replacement, checking of insulation on refrigerant linges, checking and maintainance of compressor assembly, cleaning of air handling unit complete all as spd and directed. All small nut, bolts, washers , belts any type and size will be included in the Monthly job. Note :- All other spare parts such as refrigerent, Oil etc will be measured and paid seperately.
6
-
-
... More
Charging of Refrigerant Gas F-22/ in air conditioner plant including testing and commissioning complete in satisfactory working condition all as spd and dir by EIC.
58
-
-
... More
Replacement of compressor oil including drain out existing oil, testing & labour for filling oil ,non freezing in AC plant complete all as specified and as directed. Note- (b) Only qty of filled oil accounted as per compressor capacity shall be considered for payment purposes.
(b) While filling , if any leakage/wastage of oil noticed/occured, payment for that qty shall not be accounted for.
45
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements