Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Aug 2024
Closing Date3 Oct 2024
Tender Amount₹ 1,20,00,000
Costs
EMD
₹ 1,95,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_668967_1Bid Award Id
ViewTender No
8202/CWE (NW) Mumbai/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Material and Labour for disconnection of both HT and LT connection from cable and box, taking down the disconnected transformer (Indoor type) 400 KVA to 1000 KVA capacity 11/.433 KV, installed at substation bldg and transporation of unserviceable transformer complete unit to the Transformer repairing workshop and reinstallation the same after repaired back including arrangement of necessary T & P crane and vehicle etc for loading/unloading and to carry following work
(i) Draining out transformer oil, taking down HT/LT studs and opening the top cover to checking of windings.
(ii) Desludging of core and coil assembly by hot oil pressure and checking/testing of all accessories to identify fault leve.
(iii) Brazing of burnt/disconnected copper wound surfaces, studs and connectors including replacement of unserviceable bolts, refixing of existing serviceable bolts, nuts, washers of different size and tightening properly.
(iv) Replacement of all gasket materials in top cover , HT, LT bushing using rubberized gasket sheet 4.0/6.0 mm thick duly paster with gasket cement including replacement of LT/HT coils.
(v) Repositioning of core and winding assembly inside the tank, assembling the complete unit and re-filling of old transformer oil and top up with new transformer oil including oil filtration and testing.
(vi) After assembly of complete unit of transformer load testing, insulation testing including all testing shall be carried out as per IEC and IS and test certificate shall be submitted complete all as specified and directed by Engineer-in-Charge. Note : Transformer oil and copper windings if required shall be measured and paid separately under relevant items of the schedule.
2
-
-
... More
Supply only LT leg coil of copper windings with EC grade for transformer of capacity up to 1000 KVA complete with insulation, varnishing by vacuum impregnation and baking of coil assembly, etc. complete all as specified & directed by the Engineer-in-Charge.
260
-
-
... More
Supply only HT leg coil of copper windings with EC grade for transformer of capacity up to 1000 KVA complete with insulation, varnishing by vacuum impregnation and baking of coil assembly, etc. complete all as specified & directed by the Engineer-in-Charge.
450
-
-
... More
Material & labour for shifting of transformer 11/.433 KV of capacity upto 1000KVA installed at indoor substations to other substation/installation of Navy Nagar area including disconnecting of all HT/LT connections, earth strips etc and refixing the same at reqd site (n.exc. 3 Km) alongwith arrangement of all neccessary T&P and carnes etc including testing and commissioning of transformer after re-installation at new site complete all as specified and directed.
1
-
-
... More
Material & labour for shifting of 11KV VCB panel horizontal draw out type of rupturing capacity 250/350 MVA, 400/630/800 Amps installed at indoor substations to other substation/installation of Navy Nagar area including disconnecting of all HT connections, earth strips etc and refixing the same at reqd site (n.exc. 3 Km) alongwith arrangement of all neccessary T&P and carnes etc including testing and commissioning of VCB after re-installation at new site complete all as specified and directed.
1
-
-
... More
Supply and fixing in repair of thermometer (oil temperature gauge) for indoor type transformer, all as specified and directed by Engineer -in -Charge.
6
-
-
... More
Material and labour for disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for attending leakage problem with replacement of oil seal, all gaskets, thermometer(oil temperature gauge) and reassembling complete all as directed.(Note : New Transformer oil and spare parts will be measured and paid separately excluding oil seal and thermometer i.e oil temperature gauge)
-
-
-
... More
Transformer 1000/1500KVA ,11KV/440Volt
3
-
-
... More
Transformer 400 KVA ,11KV/440Volt
1
-
-
... More
Supply only for replacement of burnt out studs and bushing with nuts of any material by providing new copper alloy stud with nut, washers and bushing with oil seals on HT side all as directed for following capacity transformers:-
-
-
-
... More
Transformer 1000/1500KVA ,11KV/440Volt
9
-
-
... More
Transformer 400KVA ,11KV/440Volt
3
-
-
... More
Supply only for replacement of burnt out studs and bushing with nuts of any material by providing new copper alloy stud with nut,washers and bushing with oil seals on LT side all as directed for following capacity transformers:-
-
-
-
... More
Transformer 1000/1500KVA ,11KV/440Volt
12
-
-
... More
Transformer 400KVA ,11KV/440Volt
4
-
-
... More
Disconnecting and dismantling the existing indoor type VCB 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350 MVA, 400/630/800 Amps from location and repair /overhauling including replacement of damaged spare parts and carrying out with the following all as specified and directed by Engineer-in-Charge.
Note :- spare parts will be measured & paid seperately
(i) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw, motor cut-off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly.
(ii) Inspecting / overhauling of tripping assembly, earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.
(iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptors by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.
(iv) Assembling all items/components parts to the respective position & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete.
21
-
-
... More
Material and labour for Opening the bus-bar chamber, CT chamber, PT Chamber and Meter chamber of HT 11KV, panel board and carry out following complete all as specified and as directed and specified by Engineer-in-Charge. Note :- spare parts shall be measured & paid seperately
(i) Inspecting/cleaning/overhauling of bus bar chamber by checking of bus bars, spout insulators, space heaters and removing dust with vacuum cleaner/Blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying STRIPPEX(A), STRIPPEX(B) and HT tape and test with High Voltage(DC) and meggering before and after high voltage test complete.
(ii) Inspecting/cleaning/overhauling metering chamber by checking of entire wiring system, all meters, selector switches, control fuses and removing dust with vacuum cleaner/blower and moisture by hot air blower and checking tightness of wiring system.
(iii) Inspecting/cleaning/overhauling of CT/PT chamber by checking of Bus bars, spout insulators, space heaters and checking of wiring system and removing dust with vacuum cleaner/blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying anti tracking paint on CT's and insulators and HT Tape.
21
-
-
... More
Overhauling, calibration and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load complete all as specified including testing complete.
21
-
-
... More
Testing of primary injection by artificial load through CT’s, on each multiple setting of over current & earth fault relay, testing polarities, ammeter and selector switch and as directed by Engineer-in-Charge.
21
-
-
... More
Material & labour for Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts AC and replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechenical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed by Engineer-in-Charge.(Note : Spare parts and oil will be measured and paid seperately)
2
-
-
... More
Fixing only HRC PT fuse 1Amps,11KV
9
-
-
... More
Supplly & fixing in repair of Power Factor meters in existing HT/LT Panel Board,Digital type 96x96mm, Voltage 110V AC, Current 5Amps, PTR 11KV/110V ,Accuracy 2deg, Aux Supply 230Volts AC, Range 100LAG-1.000-100LEAD complete all as specified and directed byEngineer-in-Charge.
4
-
-
... More
Supplly & fixing in repair of Multi Function meters in existing HT/LT Panel Board Digital type 96x96mm, Aux Supply 230Volts AC,Type: EM6436 Conzerv complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Supply only following spare parts suitable for VCB Panels Boards, Rating 11 KV , 800A,/630A26.3/18.4kA indoor type, of existing model and make complete all as specified and directed by Engineer-in-Charge.
-
-
-
... More
Spout Insulator, Epoxy type with Hardware.
6
-
-
... More
Spring return latch
9
-
-
... More
Vaccum Interupter assembly
9
-
-
... More
Opening / Closing Push Button Assembly
3
-
-
... More
Spring Charging Motor 230Volts
3
-
-
... More
Closing Coil Assembly 30V DC
4
-
-
... More
Potential Transformer, Resin cast dry type 11KV/ 110Volt /Rout3,100VA burden, Class 1 Accuracy, Trolly mounted as per existing make and model for the transformers
3
-
-
... More
Motor Charging mechanism gear Drum box as per existing make and model
3
-
-
... More
Current Transformers,resin cast dry type, 150 to 20A/ 5+5A Class1 and 5p10,15VA,26.3kA/3Sec.
8
-
-
... More
TNC Switch, 25A, Type:BCA02P004E86/S as per existing make and model
4
-
-
... More
Indicating Lamps LED type,110Volts AC as per existing make and model
20
-
-
... More
Indicating Lamps LED type,30Volts DC as per existing make and model
10
-
-
... More
Ammeters, Digital type 96x96mm, CT ration adjastable type, Class 1 acuracy, Aux Supply 230Volts/110Vots AC.
10
-
-
... More
Voltmeters,Digital type 96x96mm,Voltage 11KV, PTR 11KV/110V, class 1 acuracy, Aux Supply 230Volts AC.
4
-
-
... More
Relay Nuemerical IDMTL+Inst O/C & E/F, Type N141 (Art.No.1MYN742838D) 30V DC,CTR 5A.
4
-
-
... More
Supply & fix in repair strip type heater 80watt with control wiring suitable for indoor VCB,11 KV switch gear Panel board complete all as specified and directed by Engr-in-Charge.
60
-
-
... More
Material & Labour for repairs/ Overhauling /Servicing to Existing LT electric panels Indoor type of each Transformer by taking shut down from appropiate authority including checking loose connections and tight connection and cleaning inside/out side all connection, replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors, providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as directd and specified. Note :- The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt ACB/ MCB/MCCB/Voltmeter/ Ampermeter/CT/LED lamps of any type and discription etc and refixing the same, which shall be measured and paid as supply only vide relivent items of this schedule
(i) Cleaning inside the panel and all incoming and out going feeders i.e including MCCB/SFU/Changeover switches/Contactors/ ACB's thorouly with help of Vaccum Cleaner.
(ii) Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers
(iii) Replacing the burnt out color coated PVC Sleeve of main and fedders bus bar with appropriated size of New PVC heat shrinkable sleeves -01Job
(iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/Hrc Fuses.(Note: New items will be measured and paid separatly)-01Job
(v) Replacing burnt out control wiring of Ammeter/Voltmeter/Indicating lamps and CT'swith 2.5/1.5Sqmm copper single core,1100V grade copper conductor cable- 01Job
(vi) Replacing Burnt out Bus Bar of incomming and out going feededs with approprieted size of new bus bar (Copper/Aluminum) -01Job( Note : Bus Bar will measured and paid separately).
(vi) Replacing Burnt out Insulators of incomming and out going feeders with approprieted size of new Insulators -01Job( Note : Insulators will measured and paid separately)
(vii) Spray Painting of Panel Board with one coat of synthetic enamel paint.
6
-
-
... More
Material & labour for Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 2000 Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and directed by Engineer-in-Charge. (Note : Spare parts will be measured and paid separately)
12
-
-
... More
Supply only Spring Charging Handle suitable for upto 2000A ACB
8
-
-
... More
Supply only CT's suitable for air circuit breakers of rating 800Amps to 2000 Amps as all as per existing of Make
7
-
-
... More
Supply only Auxiliary contact block suitable for air circuit breakers of rating 800Amps to 2000 Amps as all as per existing of Make
5
-
-
... More
Supply only arcing (fixed/moving) suitable for air circuit breakers of rating 800Amps to 2000Amps as all as per existing of Make
10
-
-
... More
Supply only arc chutes (for 415V) suitable for air circuit breakers of rating 800Amps to 2000Amps as all as per existing of Make
6
-
-
... More
Supply only shunt release(110/220V DC or 240V/415V AC) suitable for air circuit breakers of rating 800Amps to 1250Amps as all as per existing make
6
-
-
... More
Supply only cluster contact suitable for air circuit breakers of rating 800Amps to 2000 Amps as all as per existing of Make
10
-
-
... More
Supply only trip coil suitable for air circuit breakers of rating 800Amps to 2000Amps as all as per existing make
6
-
-
... More
Supply & fix Aluminium Bus Bar strips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed.
Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs.
(b) Overall length of the strip shall be measured and paid after necessary conversion into weight.
(c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account.
(d) Rate of Bolts, Nuts etc shall be included in quoted rate.
12
-
-
... More
Supply only Current Transformers, 415KV 200/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel and all as specified and directed.
2
-
-
... More
Material and labour for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-Charge.
10
-
-
... More
Supply and fix cable jointing STRAIGHT THROUGH JOINT for 1.1KV grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 50 to 95 sq mm and all as directed by Engineer-in-Charge.
4
-
-
... More
Supply and fix cable jointing STRAIGHT THROUGH JOINT for 1.1KV grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 120 to 185 sq mm and all as directed by Engineer-in-Charge.
4
-
-
... More
Supply and fix cable jointing STRAIGHT THROUGH JOINT for 1.1KV grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 240 to 300 sq mm and all as directed by Engineer-in-Charge
4
-
-
... More
Supply & fix electrical Insulating mat confirming to IS15652/2006 (superceding IS: 5424-1969) B.I.S+CPRI +NTH+ERDA approved of C class of mats dielectric strength 65KV, sheet thickness not less than 3.0MM using at power houses including pasting of rubber mats with adhesive resin all as specified and directed by Engineer-in-Charge.
39
-
-
... More
Supply & fix Copper Bus Bar stips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed.
Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs.
(b) Overall length of the strip shall be measured and paid after necessary conversion into weight.
(c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account.
(d) Rate of Bolts, Nuts etc shall be included in quoted rate.
40
-
-
... More
Supply & fix of suitable type and size FRP / DMC bus bar support insulator (Bridge Insulator) for fixing the extended aluminium/copper bars, for cable terminations, duly fixed in the body of the panel board including galvanized steel bolts, nuts, washers etc.and necessary drillings, in the panel body, complete all as specified and as directed.
20
-
-
... More
Supply & fix Digital LT voltmeter with selector switch of size 96x 96mm rating 0 to 500 volt all as specified and directed.
3
-
-
... More
Supply & fix Digital LT Ammeter with selector switch of size 96x 96mm suitable for CT ratio 5amp, programmable type and all as specified and directed.
6
-
-
... More
Supply & fix in repairs indicating lamp holder with bulb LED (Red, Yellow, Blue, Green) type to indicate incoming supply suitable for 24 V DC/110 VAC/230Volts AC and all as specified and directed.
32
-
-
... More
Material & labour for Dismantling of ACB and Supply, fix ,test and commissionning in existing panel ACB 4Pole, 800 Amps, MDO, 50KA suitable for 415V, 3phase, AC supply including necessary modification in panel with 2 mm thick CRCA sheet door and suitable size of Copper bus bar with PVC sleev and inculing dismantling of burnt ACB all specified and directed.
1
-
-
... More
Material and labour for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage complete all as specified and as directed by Engineer-in-Charge.
4
-
-
... More
Supply and fix cable jointing kit Straight Through Joint for 11KV grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3 Core XLPE armoured, alluminum conductor cable of size 90 to 185 sq mm complete all as specified and as directed by Engineer-in-Charge.
6
-
-
... More
Supply and fix cable jointing kit, End Termination Joint indoor for 11KV grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size 95 to 185 sq mm complete all as specified and as directed by Engineer-in-Charge.
5
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, class HV Type I, flat, size 300 mm x 180 mm x 40 mm. laid in trenches complete all as specified and directed.
2059.44
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, class LV Type I, flat, size 250 mm x 150 mm x 40 mm. laid in trenches complete all as specified and directed.
233.33
-
-
... More
Material & labour for chequered plate 5 mm thick size as per site requirement including cutting to required shape and appling two coat of synthetic enamel paint over a coat of red oxide primer and complete all as specified and directed by Engr-in-charge.
450
-
-
... More
Material and labour for fixing angle Iron of size 25x25x6mm size and square bar applying two coats of synthetic enamel paint over a coat of red oxide primer and all as directed
85
-
-
... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)11000 Volts grade with stranded aluminium conductor of size 185 Sqmm 3 Core and all as directed by Engineer-in-Charge.
420
-
-
... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)11000 Volts grade with stranded aluminium conductor of size 95 Sqmm 3 Core and all as directed by Engineer-in-Charge.
220
-
-
... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 300 Sqmm 3.5 Core and all as directed by Engineer-in-Charge.
160
-
-
... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 Core and all as directed by Engineer-in-Charge.
90
-
-
... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 Core and all as directed by Engineer-in-Charge.
80
-
-
... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 150 Sqmm 3.5 Core and all as directed by Engineer-in-Charge.
95
-
-
... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core and all as directed by Engineer-in-Charge.
140
-
-
... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core and all as directed by Engineer-in-Charge.
130
-
-
... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 Core and all as directed by Engineer-in-Charge.
60
-
-
... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in hard/dense soil for laying of cable/ GI pipe and getting out complete all as specified and directed.
284.31
-
-
... More
Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm each complete all as specified and directed.
214.45
-
-
... More
Removing surplus soil to a distance outside MoD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
69.86
-
-
... More
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :- Only compacted thickness of sand will be measured and paid.
12.5
-
-
... More
Cutting existing road surface or hard standing, bituminous topping 15 cm but n exc 30cm girth for laying of pipes/ cables and making good distrubed surface to match with existing complete.
170
-
-
... More
Material & labour for cement concrete 1:4:8 type D2 (using 40mm grade stone aggregate) as in foundations, filling and mass concrete finished fair and even complete all as specified
6.5
-
-
... More
Material & labour for GI pipe, light grade 80mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed.
30
-
-
... More
Material & labour for GI pipe, light grade 100mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
30
-
-
... More
Material & labour for fixing of old interlocking paver tiles/blocks of any sizes recovered form item SI. No. 6 including laying over 50 mm thick sand bed compacted complete as specified and directed.
10
-
-
... More
Material & labour for 60 mm thick coloured interlocking paver tiles/ blocks M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, with gray cement & pigment lacquer finish of existing size and existing type and including laying over 50 mm thick sand bed compacted complete as specified and directed.
4
-
-
... More
Material & labour for High density poly-ethylene pipes (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 63, 75mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
250
-
-
... More
Material & labour for High density poly-ethylene pipes (HDPE) of pressure rating PN 6(0.6 Mpa), material grade PE 63, 100/110mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
650
-
-
... More
Outsourcing for maint and operation of HT sub station located at RS - 01 round the clock, having installed VCB/RMU panels of suitable capacity 01 No incoming , 06 Nos outgoing including LT distribution panels, Distribution transformer,capcitor Bank complete with deployment One electrician (skilled) and one mate electrician (semi-skilled) for each shift of 08 hours and for complete three shifts per day including daily periodically maintenance of HT/LT distribution system including minor repairs such as replacing of fuse of HT & LT, tighting/replacing of thimbles,lugs, nuts, jumpers & cleaning of panels and surrounding area. Maintaining/updating of log sheets and other documents and submit to office of AGE E/M (ES) Navy Nagar, to recording of continuous supply of electricity in Navy area/Users including cleaning of installations inside and outside of the installation complete all as specified and directed by Engr in charge. (1 One electrician (skilled) and one mate electrician (semi-skilled) combined rate x 3 shifts x 11 months = Total 33 )
33
-
-
... More
Outsourcing for maint and operation of HT sub station located at Rashi area round the clock, having installed VCB/RMU panels of suitable capacity 02 No incoming , 04 Nos outgoing including LT distribution panels, Distribution transformer,capcitor Bank complete with deployment One electrician (skilled) and one mate electrician (semi-skilled) for each shift of 08 hours and for complete three shifts per day) including daily periodically maintenance of HT/LT distribution system including minor repairs such as replacing of fuse of HT & LT, tighting/replacing of thimbles,lugs, nuts , jumpers & cleaning of panels and surrounding area. Maintaining/updating of log sheets and other documents and submit to office of AGE E/M (ES) Navy Nagar, to recording of continuous supply of electricity in Navy area/Users including cleaning of installations inside and outside of the installation complete all as specified and directed by Engr in charge. (1 One electrician (skilled) and one mate electrician (semi-skilled) combined rate x 3 shifts x 11 months = Total 33 )
33
-
-
... More
Outsourcing for maint and operation of HT Sub Station located at RS - 02 round the clock, having installed VCB/RMU panels of suitable capacity 01 No incoming, 05 Nos outgoing including LT distribution panels, Distribution transformers, Capacitor Banks complete with deployment of One electrician (skilled) for each shift of 08 hours and for complete three shifts per day including daily periodically maintenance of HT/LT distribution system including minor repairs such as replacing of fuse of HT & LT, tighting/replacing of thimbles,lugs, nuts, jumpers & cleaning of panels and surrounding area. Maintaining/updating of log sheets and other documents and submit to office of AGE E/M (ES) Navy Nagar, to recording of continuous supply of electricity in Navy area/Users including cleaning of installations inside and outside of the installation complete all as specified and directed by Engr in charge. (1 One electrician (skilled) x 3 shifts x 11 months = Total 33 )
33
-
-
... More
Note for item No 74.00 to76.00 :- (i)Total Electrician both Skilled & semi skilled required to operate the equipments/installations = 06+06+03=15 Nos per day(ii) One electrician (skilled) and one mate electrician (semi skilled) required in each shift duty of 8 hrs round the clock i.e (Total 03 shifts in a day). (iii) The rate quoted includes Oustourcing for operation & maintenance of installation on all days including Sunday/Gazetted Holidays. (iv) The cost of maintenance of documents installations charts and daily records as clarified under relevent particulars,specification shall deemed to be included in the rates quoted for above items. (v) The quoted rate deemed to be inclusive for provision of reliever duty and leave periods. (vi) The operator on duty should have proper uniform in light blue colour shirt and dark blue trauser duly printed name as MES and contractor with all protective arrangement during the duties like shoes/hand gloves and required tools for operation and maintenance of installation.
-
-
-
... More
(vii) The capacitors banks shall be operated for maintaining power factor not less than 0.95 at incomer. (viii) The cost of replacement of defective LT capacitors/contactors will be measured and paid separately. Any charges leived by State Discom for non maintaining power factor shall be recovered without any claim. (viii)The Contractor shall provide HT 11 KV hand gloves - 2 pairs and box spanner set- 1nos at each installation. (ix) The installation will be handed over in operating state on the commencement of contract though work order.
-
-
-
... More
(x) Antecedents of the Personnel engaged by the contractor to carry out the work shall be verified from police authorities and accordingly security passes shall be issued. (xi) The contractor shall be solely responsible for all personnel deployed for carrying out the above jobs and all transport required for conveyance. The rate quoted deemed to be inclusive of EPF, insurance etc of operator/electrician all as per latest norms of labour Commissioner. (xii). The labourers shall be provided with protective devices and shall wear them while working. In case any accident/ injury/ fatal or partial disability happened, the contractor shall be solely responsible for settling all claims/ compensation. Department will have a right to recover any sum indicated/ claimed by Labour Commissioner/ Court directive. (xiii) Contractor will render a certificate/ confirmation every month that minimum wages act is not violated and every employee engaged have been paid their wages only through individual bank account laborers in full and receipts there on obtained. The Contractor shall produce bank statements every month alongwith the Certificate.
-
-
-
... More
(xiv) Contractor will render a certificate/ confirmation every month that minimum wages act is not violated and every employee engaged have been paid their wages only through individual bank account laborers in full and receipts there on obtained.(xv) If the quoted amount is less than the estimated cost given at SCH A Note at Page No 14 A the lowest bidder will have to depost FDR/BGB as elaborated herein after in favour of Accepting Officer within 07 days of opening of financial bid (cover No 2).
(xvi) The deposited amount shall be the difference between estimated cost given at SCH A Note at Page No 14 A and amount quoted by lowest bidder for respective item. FDR/BGB shall be released only after satisfactory completion of work. If the contractor fails to pay minimum wages to employees, the department shall have right to with hold the said amount which will beverified by GE. The decision of Accepting Officer regarding amont to be withheld shall be final and binding. The withheld amount will be utilised by GE for payment to employees if contractor fails to pay minimum wages and balance amount if any shall only be released. If the lowest bidder fails to deposit the amount as stated above within 07 days, the contractor shall be banned for 06 months & his bid shall be rejected. The contractor shall submit 03 Nos of BGNs/FDRs of equal amount as mentioned above. The BGBs/FDRs validity shall be 04 months, 08 month & 12 months respectively for the purpose of encashment release as the case may be. (iv) The rates quoted shall be inclusive of suitable reliever wherever sundays & holidays are mentioned for working.
-
-
-