Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date10 Oct 2024
Closing Soon26 Nov 2024
Tender Amount₹ 51,07,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Total amount of Sch 'A' Part-III (Internal Electrification) brought forwarded from sl page No 33.

1

4778238

-

... More
Total amount of Sch 'A' Part-IV (Internal Water supply) brought forwarded from sl page No 35.

1

196774

-

... More
Total amount of Sch 'A' Part-V (Road/Hard standing) brought forwarded from sl page No 38.

1

1028109

-

... More
Total amount of Sch 'A' Part-VI (Sewage Disposal ) brought forwarded from sl page No 39.

1

481203

-

... More
Total amount of Sch 'A' Part-VII (Area Drainage) brought forwarded from sl page No 40.

1

1516610

-

... More
Total amount of Sch 'A' Part-VIII (External Electrification) brought forwarded from sl page No 42.

1

4815906

-

... More
Total amount of Sch 'A' part- IX (External Water supply) brought forwarded from sl page No 43.

1

464387

-

... More
Total amount of Sch 'A' part- X (Fire Fighting) brought forwarded from sl page No 44.

1

116256

-

... More
Total amount of Sch 'A' part- XI (Water Cooler) brought forwarded from sl page No 45.

1

157311

-

... More
Total amount of Sch 'A' part- XII (Arbouriculture ) brought forwarded from sl page No 46.

1

855800

-

... More
Total amount of Sch 'A' part- XIII (Lift) brought forwarded from sl page No 47.

1

2164315

-

... More
Total amount of Sch 'A' part- XIV (Demolition & Dismantling) brought forwarded from sl page No 48.

1

2644003

-

... More
Subtotal

-

-

-

... More
Sch 'A' Part- XV(MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.

-

-

-

... More
INTERNAL ELECTRIFICATION

-

-

-

... More
TPN DB(LPDB)- 12Way TPN DB, Main Incoming: 63A, TPN, MCB,Sub Incomers-40A,DP,100ma,RCBO - 3Nos. With Outgoings: -16-20A 10KA SP MCB- 36Nos.

1

-

-

... More
TPN DB(LPDB)- 8Way TPN DB, Main Incoming: 63A, TPN, MCB,Sub Incomers-40A,DP,100ma,RCBO - 3Nos. With Outgoings: -16-20A 10KA SP MCB- 24Nos.

5

-

-

... More
TPN DB(LPDB)- 6Way TPN DB, Main Incoming: 63A, TPN, MCB,Sub Incomers-40A,DP,100ma,RCBO - 3Nos. With Outgoings: -16-20A 10KA SP MCB- 18Nos.

3

-

-

... More
12Way SPN DB ,(UPS&ELDB), Incoming: 32A,DP,100ma,RCBO,. Outgoings: -16A 10KA SP MCB- 10Nos.

10

-

-

... More
TPN DB(ACDB)- 6Way TPN DB, Main Incoming: 63A, TPN, MCB,Sub Incomers-40A,DP,100ma,RCBO - 3Nos. With Outgoings: -16-20A 10KA SP MCB- 18Nos. (FUTURE PURPOSE)

3

-

-

... More
Supply,Erection,Testing & Commissioning of 200W LED Pressure die-cast aluminum housing with polycarbonate direct lens. LED module fixed on die-cast aluminum heat sink for proper thermal management and constant current driver with built-in surge protection,open & short circuit protection. System efficacy should not be less than 160lm/W and nominal system lumens should not be less than 32000 lumens, CRI 70, CCT 5700K and lifetime of 50,000 hours. Operating Temperature Range -20degC to 50degC , THD10 %, Innovative LED layout & heat sink design improve airflow and enhance heat dissipation for better performance. Input voltage range of 140V to 270V, 4kV internal + 10kV External (optional) surge protection. IP rating of IP66 and IK07 impact resistance. XE version is with EMI/EMC compliant IP67 rated & constant current driver. (+/- 10% Tolerance in Lumen/Watt is acceptable.) 200W SUSPENDED HIGHBAY WITH 160LM/W 5700K 32000 LUMENS OUTPUT 60 DEGREE BEAM ANGLE

33

-

-

... More
Supply,Erection,Testing & Commissioning of 40W LED luminaire comprising of powder coated aluminium housing and special Opal diffuser for smooth light distribution. Constant current integral LED Driver is provided, having open/short circuit protection and Built-in surge protection. Luminaire is suitable for surface mounting. Housing color: white . System efficacy should not be less than 120lm/W and nominal system lumens should not be less than 4800 lumens, CRI 80, CCT 5665K ±355K. Operating Temperature Range 0degC to 45degC, Constant Current driver suitable to operate in input voltage range of 180V to 270V (nominal rated voltage – 240V) 4kV internal surge protection . IP rating of IP20 .(+/- 10% Tolerance in Lumen/Watt is acceptable.) 40W INDUSTRIAL BATTEN EXTRUDED ALUMINIUM HOUSING WITH 120LM/W

371

-

-

... More
Supply,Erection,Testing & Commissioning of 36W LED Luminaire with visual comfort ,Recess Mounted Sleek and Seamless aesthetics with CRCA steel sheet housing and Opal diffuser fixed in separate engineered plastic frame. White powder coated Housing finish Uniformly lit special diffuser with well distributed light suitable for Armstrong and grid ceiling.The Luminaire shall be designed to emit at least 3600 nominal lumens with system efficacy of at least 120 lumen/watt.Luminaire should have CRI 80, and CCT of 5665K+355K and shall be compliant with IP20 classification. Operating Temperature Range is -10degC to 45degC. The luminaire shall be designed to ensure lumen depreciation L70 over 25000 burning hours as per LM 80 report. Constant current driver , with power factor 0.90 with a built-in surge protection of 4kV and input operating voltage range of 180 to 270V AC. Driver should comply Driver safety requirements as per IS 15885 with BIS certification.Manufacture should have in house NABL testing facility & LM80 report from LED manufacturer. LM 79 report from NABL accredited Lab shall be submitted. The luminaire should comply with all the required IEC and IS standards.The supplier or OEM shall ensure that brand name should be visible on all equipment supplied for the work and same should be eponymous as their company name as per incorporation documents. +/- 10% Tolerance in Lumen/Watt is acceptable. 36W 2X2 RECESS OR SURFACE MOUNTED CRCA HOUSING WITH 120LM/W (36W 2X2 LIGHT FIXTURE)

27

-

-

... More
Supply,Erection,Testing & Commissioning of 20W LED luminaire comprising of extruded aluminium housing with engg. plastic end caps and Opal diffuser for smooth light distribution . LED’s connected in series parallel and populated on FR4 PCB. Luminaire is suitable for surface mounting. Housing color: white . System efficacy should not be less than 120lm/W and nominal system lumens should not be less than 2400 lumens, CRI 80, CCT 6530K ±510K. Operating Temperature Range 0degC to 45degC, Constant Current driver suitable to operate in input voltage range of 180V to 270V (nominal rated voltage – 240V) 4kV internal surge protection . IP rating of IP20 . +/- 10% Tolerance in Lumen/Watt is acceptable 20W INDUSTRIAL BATTEN EXTRUDED ALUMINIUM HOUSING WITH 120LM/W (20W TUBE LIGHT)

176

-

-

... More
Supply,Erection,Testing & Commissioning of 18W LED luminaire comprising of Engineered Plastic housing and Opal diffuser for uniform lighting.. Luminaire is suitable for surface mounting with seamless integration with ceiling. Housing color: white. System efficacy should not be less than 120lm/W and nominal system lumens should not be less than 1800 lumens, CRI 80, CCT 6500K . Operating Temperature Range 0degC to 45degC, Constant Current driver suitable to operate in input voltage range of 140V to 270V (nominal rated voltage – 240V) 4kV internal surge protection . IP rating of IP20 .+/- 10% Tolerance in Lumen/Watt is acceptable 18W RECESS OR SURFACE MOUNTED DOWNLIGHT WITH 120LM/W (18W DOWN LIGHT)

36

-

-

... More
Supply,Erection,Testing & Commissioning of 12W LED luminaire comprising of Engineered Plastic housing and Opal diffuser for uniform lighting.. Luminaire is suitable for surface mounting with seamless integration with ceiling. Housing color: white. System efficacy should not be less than 100lm/W and nominal system lumens should not be less than 1200 lumens, CRI 80, CCT 6500K . Operating Temperature Range 0degC to 45degC, Constant Current driver suitable to operate in input voltage range of 140V to 270V (nominal rated voltage – 240V) 4kV internal surge protection . IP rating of IP20 . +/- 10% Tolerance in Lumen/Watt is acceptable 12W RECESS OR SURFACE MOUNTED DOWNLIGHT WITH 120LM/W (12W DOWN LIGHT)

56

-

-

... More
WATER SUPPLY EXTERNAL Supply, installation, testing and commissioning approved make high quality G.I.Class 'B' Pipes with 50 mm dia, GI malleable specials such as tees, elbows, check nuts, unions, flanges, reducers, supports for the pipes traveling above ground, clamps, etc., including threading, cutting and fixing in/on walls ceiling, ground, terrace floor etc., The rate shall include for necessary chasing the walls and making bores wherever required and making good the chased surfaces and bores in cement mortar etc., complete.

120

-

-

... More
Supply, installation, testing and commissioning of GM Ball Valve (PN 10) with solvent and threaded end connections of approved make and provided with EPDM seals, PE ball seats, true union with adjuctable support, round ball etc., complete. The valve shall be fixed after the union. The quoted rate shall include the cost of the union, nipples etc., complete of following size:-

-

-

-

... More
20 mm dia (Screwed ends)

20

-

-

... More
25 mm dia (Screwed ends)

8

-

-

... More
32 mm dia (Screwed ends)

8

-

-

... More
Supply, installation, testing and commissioning in position control lever operated type C.I body Butterfly Valve with 65 mm dia (Flanged ends) , matching companion flanges, bolts, nuts, rubber gasket etc., complete

1

-

-

... More
Supply, installation, testing and commissioning of Level Sensor shall consist of control unit, preamplifier and one full insulated probe-mounted vertically or two part insulated probe mounted from tanks side wall adjustable switching system for pump control application, the same to be housed in stove enamel painted cast aluminium weather proof suitable for black panel / wall mounting etc.

2

-

-

... More
2 core x 1.5 sq.mm cable

120

-

-

... More
Supply and Fixing of 25mm dia Air Release Valves for water risers.

2

-

-

... More
GI angle iron brackets using 40 x 40 x 6`mm thick for supporting water supply, soil and waste pipe on walls/ceiling by using hanger rods welded/grounted and the brackets shall be given two coats of anti corrosive paint over a coat of primer etc., complete as per drawing or as per site requirements.

78

-

-

... More
Supply and Installation of Main Pump of capacity 2280 Lpm 70 Mtrs Head electrical hydrant pump.

2

-

-

... More
SEWAGE DISPOSAL

-

-

-

... More
Supply, fixing, testing and commissioning of UPVC Class “3” Pipes (IS:4985) 150 mm dia soil waste and vent pipes jointed with solvent cement inclusive of all necessary specials like bends, tees, offsets, junctions, cowls etc.,laid under floor/under ceiling/on walls with suitable supports for the pipes clamps making bores in masonry / RCC slabs etc., and rendering the bores in cement mortar after laying the pipes and specials curing etc., complete.

140

-

-

... More
Supply, fixing, testing and commissioning of RCC Hume Pipes of NP2 class 200 mm dia and suitable collars filling the recess at joints of pipes with hemp dipped in hot bitumen or other suitable compound for chalking of joint by jack, setting up of loose space over the collar joints chalked with CM 1:2, finished both ends to a slope of 1:1 complete.

20

-

-

... More
Supply and fixing MS angle iron brackets using 40 x 40 x 6`mm thick for supporting water supply, soil and waste pipe on walls/ceiling by using hanger rods welded/grounted and the brackets shall be given two coats of anti corrosive paint over a coat of primer etc., complete as per drawing or as per site requirements.

100

-

-

... More
EXTERNAL ELECTRIFICATION

-

-

-

... More
11KV INDOOR HT PANEL (11KV 3WAY HT RMU PANEL)

1

-

-

... More
INCOMING (1 No's) Each Consisting of Following

-

-

-

... More
CB:-(1 Set): 11KV, 1250A, 25KA For 1Sec Horizontal Draw out type VCB Manually and Motor Operated spring charging mechanism, With 230V AC Supply for Motor,110V DC for shunt Trip coil and Closing Coil. Axu. Contact 4No+4Nc, Mechanical ON and OFF indicator and Push button, Mechanical operation counters with lightining surge arrester.The Each VCB Shall be Provided with DC Power Pack, AUXILIARY SWITCH 6NO + 6NC, Aluminium BUSBAR WITH HEAT SHRINKABLE HT SLEEVE- 1250A, 25kA/3sec STC, PAINT SHADE - FRONT / REAR , LV DOOR S & COVERS - RAL9003 (as per final technical clarification), DEGREE OF PROTECTION - IP42, BOTTOM CABLE ENTRY, MECHANICAL ON / OFF INDICATOR

-

-

-

... More
(ii) CURRENT TRANSFORMER : - (1 Set) 11KV ,25kA FOR 1SEC CURRENT TRANSFORMER:- (1 Set), CT Current Ratio:-: 100/1/1A, Core-1: CL. 0.5, 15VA - (Metering), Core-2: CL. 5p10, 15VA - (Protection), 11KV CBCT,25kA FOR 1SEC.CURRENT RATIO:- 100/1/1A

-

-

-

... More
(iii) LINE POTENTIAL TRANSFORMER (STAR - STAR-STAR) : - (1 Set) , Cast resin PT with HT and LT HRC Fuses, Ratio:11KV/√3/110v/√3 /110v/√3 Three Phase, Burden 100 VA, Core-1:-CL. 0.5 for metering, Core-2:-CL. 3P for Protection

-

-

-

... More
(iv) Measuring METER with MODBUS Protocol :- 96Sq.mm ,Class 0.5 ,Digital Ammeter with selector switch Digital type (0-1250A).

-

-

-

... More
(v) PROTECTION RELAYS: ( RELAYS as per requirement of IEC 61850 protocol), ECOX - 6 Nos. Thermal Sensors (3Nos. Cable Compartment + 3Nos. Busbar Compartment) per Feeder + 2 Nos. Humidity (Climate sensors) per offered Board 1) TRIPLE POLE NON DIRECTIONAL IDMT - 2 O/C + 1 E/F-((50/50N 51/51N) Digital Numerical relay and shall be compatable for BMS with communication port.-1 No. 2) Master Trip Relay -(86) - (1No), 3) Trip Circuit Super Vision Relay -(95) - (1No) 4) Instantaneous Overcurrent with Ground Fault-(50G) 5) ANTI PUMPING RELAY (SEPARATE CONTACTOR)-94

-

-

-

... More
(vi) BREAKER PANEL INDICATION LAMPS : 1) ON, OFF and Trip Indication Lamps for RYB. - (1 set), 2) Trip Circuit Healthy lamp - (1 set), 3) Spring Charging lamp - (1 set) 4) Auto trip - (1 set) 5) LED Type R-Y-B Phase Indication Lamps - (1 set) 6) TRIP CIRUIT SUPERVISION - (1 set) 7) TEST POSITION - (1 set) 8)SERVICE POSITION - (1 set) 9) R-Y-B HEALTHY - (1 set) DC SUPPLY HEALTHY INDICATION - (1 set)

-

-

-

... More
(vii)CONTROL SWITCHES/PUSH BUTTON AND OTHER ACCESSORIES: T-N-C Switch (Breaker Control Switch) - (1 set), Trip circuit Healthy Push Button-(1 set), AC ON/OFF SWITCH - (1 set), STRIP HEATER - (1 set), THERMOSTAT - (1 set), CUBICLE ILLUMINATING LAMP - CFL - (1 set), 15A, 230V, 3 PIN PLUG & SOCKET - (1 set), MOTOR ON / OFF SWITCH - (1 set), EMERGENCY TRIP PUSH BUTTON - (1 set), MCBs - (1 set), LOCAL/REMOTE SELECTOR SWITCH - (1 set), FACIA ANNUNCIATOR + AC / DC FAIL + RS 485 - (1 set), HOOTER - (1 set) TTB FOR RELAY (Metering and Protection TTB shall be separately provided) - (1 set), Control Wiring with appropriate colors - (1 set), 230V AC/110V DC Power Pack - 1 No, Alarm scheme with hooter, Accept and Reset Button with 23Way Annunciation window. - (1 set), Bus Bar with 1250Amps , 25KA Aluminium (Electrical Grade). - (1 set), Note: The CT's/PT's specified are Cast Resin and Testing / Approval are as per the ERDA Test Lab.

-

-

-

... More
(b) OUTGOING - 1&2: (2 No's) Each Consisting of Following

2

-

-

... More
(i) CB:-(1 Set): 11KV, 800A, 25KA For 1Sec Horizontal Draw out type VCB Manually and Motor Operated spring charging mechanism, With 230V AC Supply for Motor,110V DC for shunt Trip coil and Closing Coil. Axu. Contact 4No+4Nc, Mechanical ON and OFF indicator and Push button, Mechanical operation counters with lightining surge arrester.The Each VCB Shall be Provided with DC Power Pack, AUXILIARY SWITCH 6NO + 6NC, Aluminium BUSBAR WITH HEAT SHRINKABLE HT SLEEVE- 800A, 25kA/1sec STC, PAINT SHADE - FRONT / REAR , LV DOOR S & COVERS - RAL9003 (as per final technical clarification), DEGREE OF PROTECTION - IP42, BOTTOM CABLE ENTRY, MECHANICAL ON / OFF INDICATOR

-

-

-

... More
(ii) CURRENT TRANSFORMER : - (1 Set), 11KV ,25kA FOR 1SEC CURRENT TRANSFORMER:- (1 Set), CT Current Ratio:-: 100/1/1A, Core-1: CL. 0.5, 15VA - (Metering), Core-2: CL. 5p10, 15VA - (Protection), 11KV CBCT,25kA FOR 1SEC.CURRENT RATIO:- 100/1/1A

-

-

-

... More
(iii) LINE POTENTIAL TRANSFORMER (STAR - STAR-STAR) : - (1 Set), Cast resin PT with HT and LT HRC Fuses, Ratio:11KV/√3/110v/√3/110v/√3 Three Phase, Burden 100 VA, Core-1:-CL. 0.5 for metering ,Core-2:-CL. 3P for Protection

-

-

-

... More
(iv) Measuring METER with MODBUS Protocol :- 96Sq.mm ,Class 0.5 ,Digital Ammeter with selector switch Digital type (0-1250A).

-

-

-

... More
(v) PROTECTION RELAYS: ( RELAYS as per requirement of IEC 61850 protocol), ECOX - 6 Nos. Thermal Sensors (3Nos. Cable Compartment + 3Nos. Busbar Compartment) per Feeder + 2 Nos. Humidity (Climate sensors) per offered Board) 1) TRIPLE POLE NON DIRECTIONAL IDMT - 2 O/C + 1 E/F-((50/50N 51/51N) Digital Numerical relay and shall be compatable for BMS with communication port.-1 No. 2) Master Trip Relay -(86) - (1No) 3) Trip Circuit Super Vision Relay -(95) - (1No) 4) Instantaneous Overcurrent with Ground Fault-(50G) 5) ANTI PUMPING RELAY (SEPARATE CONTACTOR)-94

-

-

-

... More
(vi) BREAKER PANEL INDICATION LAMPS : 1) ON, OFF and Trip Indication Lamps for RYB. - (1 set), 2) Trip Circuit Healthy lamp-(1 set), 3) Spring Charging lamp - (1 set), 4) Auto trip. - (1 set), 5) LED Type R-Y-B Phase Indication Lamps. - (1 set), 6) TRIP CIRUIT SUPERVISION - (1 set), 7) TEST POSITION - (1 set), 8) SERVICE POSITION - (1 set), 9) R-Y-B HEALTHY - (1 set), 10) DC SUPPLY HEALTHY INDICATION - (1 set)

-

-

-

... More
(vii) CONTROL SWITCHES/PUSH BUTTON AND OTHER ACCESSORIES : T-N-C Switch (Breaker Control Switch) - (1 set), Trip circuit Healthy Push Button - (1 set), DC ON/OFF SWITCH - (1 set), AC ON/OFF SWITCH - (1 set), STRIP HEATER - (1 set), THERMOSTAT - (1 set), CUBICLE ILLUMINATING LAMP - CFL - (1 set), 15A, 230V, 3 PIN PLUG & SOCKET - (1 set), MOTOR ON / OFF SWITCH - (1 set), EMERGENCY TRIP PUSH BUTTON - (1 set), MCBs - (1 set), LOCAL/REMOTE SELECTOR SWITCH - (1 set), FACIA ANNUNCIATOR + AC / DC FAIL + RS 485 - (1 set), HOOTER - (1 set), TTB FOR RELAY (Metering and Protection TTB shall be separately provided) - (1 set), Control Wiring with appropriate colors - (1 set), 230V AC/110V DC Power Pack - 1 No, Alarm scheme with hooter, Accept and Reset Button with 23Way Annunciation window. - (1 set), Bus Bar with 1250Amps , 25KA Aluminium (Electrical Grade). - (1 set), Note: The CT's/PT's specified are Cast Resin and Testing / Approval are as per the ERDA Test Lab. Busbar: 11KV, 800A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 25KA for 1 Sec. - LS (with 50% Neutral)

-

-

-

... More
(2) VCB ISOLATOR (OUTDOOR) (As mentioned Below) (a) 11 KV, HT VCB OUTDOOR PANEL-(ICOG)-1 set, INCOMER-1: 11KV, 800A, 25.1KA/3 SEC-1 no's , 3P indoor VCB With 88: Spring Charging Motor Aux. Supply - 230V AC- 1 no's, 52a: Closing Coil - 24V DC or 110VDC-1 no's, 52b: Tripping Coil - 24V DC or 110VDC -1 No's, Mechanical ON/OFF Indicator and Push button, mechanical Operation Counter-1 No's, 25A Breaker Control Switch : 1C+1T -1 No's, Indication lamp ON (Red)-1 No's, Indication lamp OFF (Green)-1 Nos, Indication lamp Trip (Ambar)-1 No's, Breaker test position (White) -1 No's, Breaker service position (Yellow)-1 No's, Spring Charging (Blue)-1 No's, Trip Circuit Healthy (white) -1No's, Indicating Lamps R-Phase 110V AC-1No's, Indicating Lamps Y-Phase 110V AC-1No's, Indicating Lamps B-Phase 110V AC-1No's, 6A Local/Remote Selector Switch-1No's, Emg Stop Push Button with NO+NC ELEMENT-1No's, Potential Transformer:-Resin Cast Single Phase Fixed Type Potential Transformer With 1A HRC Fuses, PTR: 11KV/√3/110v/√3, Core1: Class:1.0, Burden:-50VA/Phase -3 No's, PT HT FUSE-3Nos, Current Transformer:-Epoxy Cast Resin Current Transformer, CTR:100-150/1A, Core1:7.5VA, Class: 1.0, Core2: 7.5VA Class: 5P10-3 No's, Master Trip Relay(86)-1 No's,Numerical Protection relay (50/50N)-1 No's, Small win Annunciator-1 No's, Hooter-1 No's, Power Pack With 7AH Battery-1 No's , Ammeter,cl-1.0-1 No's, Voltmeter with Cl:1.0-1No's, Ammeter Selector Switch-1No's, Voltmeter Selector Switch-1 No's, Voltmeter Selector Switch-1 No's, CT's Terminal's-8 No's,Panel Space Heater, 80W, 230V AC-1 No's, Thermostat-1 No's, Toggle Switch :-Heater ON/OFF (230V AC, 10A)-1 No's, 06A/16A SPN/DP 10KA MCB-1 No's.

1

-

-

... More
(3) DRY TYPE TRANSFORMERS: Supply, erection, testing, commissioning and installation of 11KV / 433V, 1250KVA, 50Hz, Z=6.25% (DRY TYPE) , transformer with OLTC, RTCC & AVR with ±10% instep of 1.25% manufactured as per IS 1180 Energy Efficiency Level 2 with all standard accessories and as per MSEDCL approved standards as per Technical Specification and SLD. Rating:- 1250 KVA 1) Installation:- INDOOR ONLY 2) Type Two Windings, Cast Resin-Dry Type 3) Cooling:- AN/AF (unless otherwise specified) 4) Phase:- 3 Phase 5) Primary Voltage:- 11kV (As specified in BoQ) 6) Secondary Voltage:- 433 V 7)Tap changeover:- ON LOAD ( As specified in BoQ) 8)Tapping on windings HV/LV :-HV winding 9)Motorized load tap changer (if specified):- -15% to +5%, In steps of 1.25% 10)Winding connection:- H.V Delta ,L.V Star grounded 11) Winding material:- Copper 12) Vector Group:- Dyn 11 13) Percentage Impedance:- As per IS 14) Losses Unless otherwise specified,:- as per table 7.1 (Page no, 76) of ECBC-2017 Revision: April, 2018 and subsequent revisions thereof, by BEE, Govt. of India 15) Neutral CT:- REQUIRED 16) Fault Level HV system:- 350 MVA 17) Transformer Neutral:- Effectively earthed through an additional bushing on LV side 18) Transformer Terminations: Primary side 11kV (E) XLPE Aluminum Conductor armored cable 19) Secondary side Bus-duct:- (2000A SANDWICH TYPE BUSDUCT)

-

-

-

... More
MAIN PCC PANEL ( The MPCC Consisting of the Following ) (INDOOR PANEL)

1

-

-

... More
ELECTRICAL + MECHANICAL INTERLOCKING (ALL THE NECESSARY ACCESSORIES SHOULD BE TAKEN INTO THE PANEL FOR E+M INTRACTION) Incomer-1 (From EB - Transformer - 1), 2000A, 4P, EDO ACB of 50KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases -6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 2000/5A, CL-1, 15VA, Tape wound CT's - 3Nos Incomer-2 (From DG PANEL), 630A, 4P, MCCB of 50KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases - 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 320/5A, CL-1, 15VA, Tape wound CT's - 3Nos

-

-

-

... More
Outgoing Feeders on BUSBAR-1: 1) 1250A, 4P, EDO ACB of 50KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases -2 Nos (1 DEDICATED + 1SPARE) Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 1250/5A, CL-1, 15VA, Tape wound CT's - 3Nos. 2) 630A, 4P, MCCB of 35KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases -2 Nos (1 DEDICATED + 1 SPARE). Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 630/5A, CL-1, 15VA, Tape wound CT's - 3Nos 3) 320A, 4P, MCCB of 35KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases -1 Nos (1 DEDICATED ). Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 320/5A, CL-1, 15VA, Tape wound CT's - 3Nos 4) 200A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -1 Nos (1 DEDICATED ). Each consisting of following 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 200/5A, CL-1, 15VA, Tape wound CT's - 3Nos 5). 125A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -4 Nos (4DEDICATED). Each consisting of following 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set)On,Off & Trip Indications: (1 sets ) 125/5A, CL-1, 15VA, Tape wound CT's - 3Nos 6) 100A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -1 Nos (1DEDICATED). Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ), 100/5A, CL-1, 15VA, Tape wound CT's - 3Nos

-

-

-

... More
(iii) Busbar-1: 415V, 3000A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 50KA for 1 Sec. - LS (with 50% Neutral)

-

-

-

... More
(iv) Outgoing Feeders on BUSBAR-2: 1600A, 4P, EDO ACB of 50KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases -2 Nos (1 DEDICATED + 1SPARE). Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No.LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 1600/5A, CL-1, 15VA, Tape wound CT's - 3Nos

-

-

-

... More
(v) Busbar-2: 415V, 3000A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 50KA for 1 Sec. - LS (with 50% Neutral)

-

-

-

... More
(vi) BUS COUPLER : 2000A, 4P, EDO ACB of 50KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases

-

-

-

... More
(vii) SPD: This panel shall include Mains Incoming Panel:Protection at the main incomer of the power supply system has to be connected at the Main Distribution Board after the incoming breaker. CLASS B SPD -TYPE I -MAIN DISTRIBUTION PANEL(THREE PHASE+ NEUTRAL) The SPD should be connected between Phase and Neutral and between Neutral and Earth with the following ratings: Nominal Voltage, Un -230V, 50/60 Hz,Line to Neutral-MOV with built in thermal fuse,Neutral to Earth-Spark Gap Encapsulated / Non-exhausting,MCOV of 320V Total Impulse current -50 kA (10/350µ sec) - 12.5 kA each. Voltage protection level 1.5 kV. Protection Modes for : L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) Mounting on -Din rail Max. Back-up fuse-Up to 500 amps max. Depending up on panel design & breaking capacity. rovals:UL Degree of Protection:IP 20 Operating temperature range:-40°C to +85°C Response Time- 100 nano seconds Remote signaling:Visual Model Number- ,MCD 50 B 0S -320 V+MCD 125 B NPE ,BACK UP FUSE NEEDED 250 A, 3PHASE , 4 WIRE SYSTEM DIN RAIL MOUNTED SPD CLASS B SPD-TYPE-1 Quantity-2No

-

-

-

... More
(b) 600KVAR CAPACITOR BANK APFC PANEL - 1No Panel consisting of the following

1

-

-

... More
(i) Incomers: 1250A, 4P, ACB of 50KA breaking capacity with O/C, S/C, E/F and Micro Processor based Releases with RS485 communication port -1 No. Each consisting of following. 6A, Control MCB - 3Nos LED type R Y B Phase indicating lamps - 1 set ON / OFF INDICATING LAMPS Voltmeter of range (0-415V) with selector switch - 1 set Ammeter of range (0-1250A) with selector switch - 1 set 1250/5A, CL-1, 10VA CT's with tape wound - 3 nos. Phase Failure Relay (PFR) 10 Stage APFCR Controller.

-

-

-

... More
(ii) Outgoings: 1) 250A, TP ,35KA Thermal Magnetic MCCB with OverLoad & Short circuit Protections- 5No's. Each consisting of following 100KVAR CAPACITOR DUTY CONTACTOR 7% DETUNED COPPER REACTOR100KVAR CAPACITOR BANK @ 480V MPP HEAVY DUTY CAPACITOR BANK ON / OFF INDICATING LAMPS START/STOP PUSH BUTTONS 2) 63A, 3P, MCCB of 10KA breaking capacity with O/C, S/C, E/F and Thermal Magnetic based Releases -3Nos. Each consisting of following 25KVAR CAPACITOR DUTY CONTACTOR 7% DETUNED COPPER REACTOR 25KVAR CAPACITOR BANK @ 480V MPP HEAVY DUTY CAPACITOR BANK ON / OFF INDICATING LAMPS START/STOP PUSH BUTTONS 3) 40A, 3P, MCCB of 10KA breaking capacity with O/C, S/C, E/F and Thermal Magnetic based Releases -1Nos. Each consisting of following 15KVAR CAPACITOR DUTY CONTACTOR 7% DETUNED COPPER REACTOR 15KVAR CAPACITOR BANK @ 480V MPP HEAVY DUTY CAPACITOR BANK ON / OFF INDICATING LAMPS START/STOP PUSH BUTTONS 4) 32A, 3P, MCCB of 10KA breaking capacity with O/C, S/C, E/F and Thermal Magnetic based Releases -1Nos. Each consisting of following 10KVAR CAPACITOR DUTY CONTACTOR 7% DETUNED COPPER REACTOR 10KVAR CAPACITOR BANK @ 480V MPP HEAVY DUTY CAPACITOR BANK ON / OFF INDICATING LAMPS START/STOP PUSH BUTTONS Note - All Capacitors Should be with DETUNED FILTERS.

-

-

-

... More
(iii) Bus Bar: 415V, 1250A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 50 KA for 1 Sec. - LS

-

-

-

... More
(iv) SPD: This panel shall include Mains Incoming Panel: Protection at the main incomer of the power supply system has to be connected at the Main Distribution Board after the incoming breaker. CLASS B SPD -TYPE I -MAIN DISTRIBUTION PANEL (THREE PHASE+ NEUTRAL). The SPD should be connected between Phase and Neutral and between Neutral and Earth with the following ratings:- 1. Nominal Voltage, Un -230V, 50/60 Hz, Line to Neutral-MOV with built in thermal fuse, Neutral to Earth-Spark Gap Encapsulated / Non-exhausting, MCOV of 320V 2. Total Impulse current -50 kA (10/350µ sec) - 12.5 kA each. 3. Voltage protection level 1.5 kV. 4. Protection Modes for: L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) 5. Mounting on -Din rail Max. 6. Back-up fuse-Up to 500 amps max. 7. Depending up on panel design & breaking capacity. 8. Approvals :UL 9. Degree of Protection : IP 20 10. Operating temperature range:-40°C to +85°C 11. Response Time- 100 Nano seconds Remote signalling Quantity-2No

-

-

-

... More
(c) GROUND FLOOR (LIGHTING,POWER,AC DISTRIBUTION-LPDB AND ACDB)

1

-

-

... More
(i) Incomer: 125A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -Each consisting of following. 6A, control MCB of C-Curve - 3Nos, Multifunction Meter(MFM) With RS485 communication port - 1 No, LED Type R-Y-B Phase Indication Lamps -(1 set), On,Off & Trip Indications: (1 sets ), 125/5A, CL-1, 15VA, Tape wound CT's - 3Nos

-

-

-

... More
(ii) Outgoing: 63A, TPN, MCB of 10KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -7 Nos (4 DEDICATED + 3 SPARE)

-

-

-

... More
(iii) Busbar: 415V, 160A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 25 KA for 1 Sec. - LS

-

-

-

... More
(iv) SPD: This panel shall include Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system.Class B+C/Class I+II (according to IEC 61643 - 1)(THREE PHASE+ NEUTRAL) Class B+C/Class I+II (according to IEC 61643 - 1) Pluggable type SPD with potential free contact and thermal disconnector has to be connected between Line and Neutral and SPD of Spark Gap type between Neutral and Earth of following ratings should include base element & pluggable arresters. If required, remote signaling should be provided for remote monitoring purpose. Nominal Voltage, Un -230V, 50/60 Hz,Line to Neutral-MOV with built in thermal fuse,Neutral to Earth-Spark Gap Encapsulated / Non-exhausting,MCOV of 320V Nominal current -90 kA (8/20µ sec) - 30 kA each. Voltage protection level 1.4 kV. Protection Modes for : L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) Mounting on -Din rail Max. Back-up fuse-Up to 160 amps max. Depending up on panel design & breaking capacity. Approvals: OVE Degree of Protection:IP 20 Operating temperature range:-40°C to +85°C Response Time- 25nano seconds Quantity-1No

-

-

-

... More
(d) (TYPICAL) FIRST & SECOND FLOOR (LIGHTING,POWER,AC DISTRIBUTION-LPDB AND ACDB)

2

-

-

... More
(i) Incomer: 125A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -Each consisting of following. 6A, control MCB of C-Curve - 3Nos, Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set) , On,Off & Trip Indications: (1 sets ), 125/5A, CL-1, 15VA, Tape wound CT's - 3Nos

-

-

-

... More
(ii) Outgoing: 63A, TPN, MCB of 10KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -7Nos (4 DEDICATED + 3 SPARE)

-

-

-

... More
(iii) Busbar: 415V, 160A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 25 KA for 1 Sec. - LS

-

-

-

... More
(iii) Busbar: 415V, 160A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 25 KA for 1 Sec. - LS

-

-

-

... More
(iv) SPD: This panel shall include Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Class B+C/Class I+II (according to IEC 61643 - 1)(THREE PHASE+ NEUTRAL) Class B+C/Class I+II (according to IEC 61643 - 1) Pluggable type SPD with potential free contact and thermal disconnector has to be connected between Line and Neutral and SPD of Spark Gap type between Neutral and Earth of following ratings should include base element & pluggable arresters. If required, remote signaling should be provided for remote monitoring purpose. Nominal Voltage, Un -230V, 50/60 Hz,Line to Neutral-MOV with built in thermal fuse,Neutral to Earth-Spark Gap Encapsulated / Non-exhausting,MCOV of 320V Nominal current -90 kA (8/20µ sec) - 30 kA each. Voltage protection level 1.4 kV. Protection Modes for : L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) Mounting on -Din rail Max. Back-up fuse-Up to 160 amps max. Depending up on panel design & breaking capacity. Approvals: OVE Degree of Protection:IP 20 Operating temperature range:-40°C to +85°C Response Time- 25nano seconds Quantity-1No

-

-

-

... More
(e) THIRD FLOOR (LIGHTING,POWER,AC DISTRIBUTION-LPDB AND ACDB)

1

-

-

... More
(i) Incomer: 125A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps.- (1 set)On,Off & Trip Indications: (1 sets ) 125/5A, CL-1, 15VA, Tape wound CT's - 3Nos

-

-

-

... More
(ii) Outgoing: 63A, TPN, MCB of 10KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -9 Nos (6 DEDICATED + 3 SPARE)

-

-

-

... More
(iii) Busbar: 415V, 160A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 25 KA for 1 Sec. - LS

-

-

-

... More
(iv) SPD: This panel shall include Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Class B+C/Class I+II (according to IEC 61643 - 1)(THREE PHASE+ NEUTRAL) Class B+C/Class I+II (according to IEC 61643 - 1) Pluggable type SPD with potential free contact and thermal disconnector has to be connected between Line and Neutral and SPD of Spark Gap type between Neutral and Earth of following ratings should include base element & pluggable arresters. If required, remote signaling should be provided for remote monitoring purpose. Nominal Voltage, Un -230V, 50/60 Hz,Line to Neutral-MOV with built in thermal fuse,Neutral to Earth-Spark Gap Encapsulated / Non-exhausting,MCOV of 320V Nominal current -90 kA (8/20µ sec) - 30 kA each. Voltage protection level 1.4 kV. Protection Modes for : L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) Mounting on -Din rail Max. Back-up fuse-Up to 160 amps max. Depending up on panel design & breaking capacity. Approvals: OVE Degree of Protection:IP 20 Operating temperature range:-40°C to +85°C Response Time- 25nano seconds Quantity-1No

-

-

-

... More
(f) ALL FLOORS ( EMERGENCY LIGHTING AND UPS POWER DISTRIBUTION-EL&UPSDB )

1

-

-

... More
(i) Incomer: 100A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -Each consisting of following.

-

-

-

... More
(ii) Outgoing: 32A, DP, MCB of 10KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -10 Nos (7 DEDICATED + 3 SPARE)

-

-

-

... More
(iii) Busbar: 415V, 125A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 25 KA for 1 Sec. - LS

-

-

-

... More
(g) COMMON SERVICE PANEL

1

-

-

... More
(i) Incomer: 320A, 4P, MCCB of 35KA breaking capacity with O/C, S/C, E/F and Micro proceser based Releases - Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. -(1 set) On,Off & Trip Indications: (1 sets ) 320/5A, CL-1, 15VA, Tape wound CT's - 3Nos

-

-

-

... More
(ii) Outgoing: 1) 100A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -2 Nos (1 DEDICATED + 1SPARE) 2) 63A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -3 Nos (1 DEDICATED + 2SPARE) 3) 32A, 4P, MCCB of 25KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -9 Nos (7 DEDICATED + 2SPARE)

-

-

-

... More
(iii) Busbar:415V, 400A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 35 KA for 1 Sec. - LS

-

-

-

... More
(iv) SPD: This panel shall include Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Class B+C/Class I+II (according to IEC 61643 - 1)(THREE PHASE+ NEUTRAL) Class B+C/Class I+II (according to IEC 61643 - 1) Pluggable type SPD with potential free contact and thermal disconnector has to be connected between Line and Neutral and SPD of Spark Gap type between Neutral and Earth of following ratings should include base element & pluggable arresters. If required, remote signaling should be provided for remote monitoring purpose. Nominal Voltage, Un -230V, 50/60 Hz,Line to Neutral-MOV with built in thermal fuse,Neutral to Earth-Spark Gap Encapsulated / Non-exhausting,MCOV of 320V Nominal current -90 kA (8/20µ sec) - 30 kA each. Voltage protection level 1.4 kV. Protection Modes for : L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) Mounting on -Din rail Max. Back-up fuse-Up to 160 amps max. Depending up on panel design & breaking capacity. Approvals: OVE Degree of Protection:IP 20 Operating temperature range:-40°C to +85°C Response Time- 25nano seconds Quantity-1No

-

-

-

... More
(h) INDUSTRIAL SOCKET PANEL

1

-

-

... More
(i) Incomer: 630A, 4P, MCCB of 50KA breaking capacity with O/C, S/C, E/F and Micro proceser based Releases - Each consisting of following. 6A, control MCB of C-Curve - 3Nos Multifunction Meter(MFM) With RS485 communication port - 1 No. LED Type R-Y-B Phase Indication Lamps. - (1 set) On,Off & Trip Indications: (1 sets ) 630/5A, CL-1, 15VA, Tape wound CT's - 3Nos

-

-

-

... More
ii) Outgoing: 1) 32A, TP, MCB of 10KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -43 Nos ( 40 DEDICATED + 3SPARE) 2) 20A, DP,

-

-

-

... More
(MCB of 10KA breaking capacity with O/C, S/C and Thermal Magnetic based Releases -43 Nos ( 40 DEDICATED + 3SPARE)

-

-

-

... More
(iii) Busbar: 415V, 800A, 3Ph, 4wire 50Hz, Aluminium busbars (91E electrical grade) having withstand ability symmetrical fault level of 50 KA for 1 Sec. - LS

-

-

-

... More
(iv) SPD: This panel shall include Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Protection at the Main Distribution Board / Sub distribution board or in LT panel of the power supply system. Class B+C/Class I+II (according to IEC 61643 - 1)(THREE PHASE+ NEUTRAL) Class B+C/Class I+II (according to IEC 61643 - 1) Pluggable type SPD with potential free contact and thermal disconnector has to be connected between Line and Neutral and SPD of Spark Gap type between Neutral and Earth of following ratings should include base element & pluggable arresters. If required, remote signaling should be provided for remote monitoring purpose. Nominal Voltage, Un -230V, 50/60 Hz,Line to Neutral-MOV with built in thermal fuse,Neutral to Earth-Spark Gap Encapsulated / Non-exhausting,MCOV of 320V Nominal current -90 kA (8/20µ sec) - 30 kA each. Voltage protection level 1.4 kV. Protection Modes for : L & N to PE. Maximum Discharge Current Imax per pole-50 kA (8/20µ sec) Mounting on -Din rail Max. Back-up fuse-Up to 160 amps max. Depending up on panel design & breaking capacity. Approvals: OVE Degree of Protection:IP 20 Operating temperature range:-40°C to +85°C Response Time- 25nano seconds Quantity-1No

-

-

-

... More
(5) BUS BAR TRUNKING SYSTEM :

-

-

-

... More
NOTE: 1) ALL THE BUS DUCTS WHICH ARE BEING LAID AND TERMINATED OUTDOOR SHALL BE PROVIDED WITH IP-68 PROTECTIONS ALONG WITH CANOPY.

-

-

-

... More
(a) Supply, erection, testing and commissioning of 415V, 50 Hz. 3Phase+50% Neutral, 2000 Amps 50 kA 4P (IP 68) Sandwich BUSDUCT [Between TRANSFORMER TO MAIN PCC PANEL] . The Busbar Trunking System shall be of Sandwich construction, . It shall be possible to mount the Busbar Trunking System in any orientation without affecting the current rating. The busbars should be made of high conductivity electrical grade Aluminum (60%). The Purity of Aluminum conductor should not be less than 99.6%, the joint area should be Tin plated. Inside should be Class-F, each layer shall have withstand breakdown voltage of minimum 6kv. The insulation material used shall be of minimum class of (155 deg.c) with UL Certified. Housing shall be made of 1.6mm electro-galvanized sheet steel, epoxy powder coated with RAL7032 shade, indoor busduct must be IP-54 / IP-55 & Outdoor busduct should be IP-65 / IP-66 with canopy. This includes bends/flangers/connectors etc as per the requirements to work done as per the site conditions.

15

-

-

... More
(6) UPS/INVERTERS : Supply , Erection ,testing and Commisioning of 20KVA Microprocessor based double conversion on line UPS System with 3 phase input and 3ph output IGBT Based as per the requirement/ Technical Specifications including SMF Batteries to provide 90 Minutes backup with necessary accessories (Considered Battery Racks, interlinks, 5 Mtrs UPS to battery cable) .

1

-

-

... More
(7) HT/LT CABLE SUPPLYING AND LAYING. Supplying, laying, testing and commissioning of cables of the following sizes of cables on trays built up trenches or through GI pipes or clamping to column wall or structure using GI spacers and saddles (at an interval of 300mm for cables of OD up to 25mm and 500mm for the cables) scope shall includes supply of these saddles, hardware and consumables. Cables laid in trays shall be dressed and tied with black nylon ropes in the horizontal portions and clamped using the GI saddles at every 750mm in the vertical portion. What ever cables are laid through GI pipes scopes shall also include sealing the mouth of the GI pipes. Where ever cables are to be laid in built up trenches work shall be includes opening the RCC slabs before laying and replacing them after laying. The work shall be carried out as per the specification and as per the directions of the Engineer-in-charge.NOTE:All Aluminium Cable(Size) complying to IS 7098 Part 1,XLPE insulation,Inner & Outer Sheath complying ST2, Armoured Cable.

-

-

-

... More
4 C XLPE Cable ( AL & CU both)

-

-

-

... More
3 C x 2.5 Sq.mm Cu,Flexible Cable (Specifcally For Internal Cabling/Wiring of all the High Bay Light Fixtures.)

500

-

-

... More
3 C x 10 Sq.mm AL,Ar XLPE Cable

650

-

-

... More
CABLE TERMINATIONS (including supply of cable glands and lugs)

-

-

-

... More
3.5 C AL,Ar XLPE Cable (Only AL)

-

-

-

... More
3.5 C x 240 Sq.mm

48

-

-

... More
3.5 C x 185 Sq.mm

4

-

-

... More
3.5 C x 95 Sq.mm

8

-

-

... More
3.5 C x 70 Sq.mm

4

-

-

... More
3.5 C x 50 Sq.mm

2

-

-

... More
3.5 C x25 Sq.mm

14

-

-

... More
CABLE TERMINATIONS (including supply of cable glands and lugs) Aliminium Armoured XLPE Cable OF FOLLOEING SIZES4 C XLPE Cable ( AL & CU both)

-

-

-

... More
4 C x 25 Sq.mm

30

-

-

... More
4 C x 10 Sq.mm

80

-

-

... More
3 C x 6 Sq.mm

80

-

-

... More
3 C x 2.5 Sq.mm Cu,Flexible Cable (Specifcally For Internal Cabling/Wiring of all the High Bay Light Fixtures.)

52

-

-

... More
3 C x 10 Sq.mm AL,Ar XLPE Cable

14

-

-

... More
FRLS Control Cables. (All below Mentioned Cables are Provided for Transformer and DG set Control Wiring)

-

-

-

... More
14Cx2.5 Armoured Copper Cable.

350

-

-

... More
4Cx2.5 Armoured Copper Cable.

150

-

-

... More
3Cx2.5 Armoured Copper Cable.

250

-

-

... More
2Cx2.5 Armoured Copper Cable.

300

-

-

... More
3.5 C AL,Ar XLPE Cable (Only AL)

-

-

-

... More
100X10mm GT flat

200

-

-

... More
50X6 mm GI flat

4500

-

-

... More
40X6 mm GI flat

100

-

-

... More
75X6 mm Copperflat

200

-

-

... More
CABLE TRENCH/CABLE TRAYS.

-

-

-

... More
CABLE TRAYS

-

-

-

... More
Supply & Installation of heavy duty hot dipped galvanized perforated type Cable trays of following sizes, suspended from ceiling or fixed vertically on wall / column 2mm thick as per including necessary supports like anchor bolts, hangers, brackets etc. and accessories like Elbows, Bends, Tee, requisite support / suspenders, hardware etc. as per site requirement. All supporting structure & hardware including nuts & bolts etc. shall be of galvanized iron as approved. Height of cable tray will be 50 mm.

-

-

-

... More
Without Cover

-

-

-

... More
600 mm width perforated cable tray

600

-

-

... More
450 mm width perforated cable tray

400

-

-

... More
300 mm width perforated cable tray

150

-

-

... More
150 mm width perforated cable tray

150

-

-

... More
75 mm width perforated cable tray

150

-

-

... More
50 mm width perforated cable tray

150

-

-

... More
With Cover

-

-

-

... More
600 mm width perforated cable tray

1200

-

-

... More
450 mm width perforated cable tray

600

-

-

... More
300 mm width perforated cable tray

150

-

-

... More
150 mm width perforated cable tray

200

-

-

... More
75 mm width perforated cable tray

350

-

-

... More
50 mm width perforated cable tray

50

-

-

... More
Ladder trays Without cover

-

-

-

... More
600 MM width Ladder cable tray

600

-

-

... More
450 mm width Ladder cable tray

150

-

-

... More
300 mm width Ladder cable tray

250

-

-

... More
150 mm width Ladder cable tray

50

-

-

... More
75 mm width Ladder cable tray

50

-

-

... More
50 mm width Ladder cable tray

50

-

-

... More
Steel for supporting the above Cable Trays

1

-

-

... More
Supply and fixing 45W LED street light fitting made up of pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection, bracket 1.5 m long, made of 40 mm dia GI pipe, light grade, including GI clamps, nuts, bolts and washers with two coats of synthetic enamel paint over a coat of red oxide primer, input voltage range 220-240 V, including necessary electrical connections from ceiling rose to light fitting with 3 core, 1.5 Sqmm flexible copper conductor cable complete as as specified and as directed.

25

-

-

... More
SAFETY ACCESSORIES : Supply and installation of following safety accessories., Pair of sand bucket (two buckets on one stand) - 7, Shock treatment chart in Hindi and English duly framed - 2, First Aid Box - 5, Enamelled Danger Boards for 11KV - 2, 3 Buckets 9Ltr. Capacity with angle Iron stand - 1, Electrical Insulating Rubber Mats for 11KV and 433V (HT and LT panels) should be of 3.0mm and 2.0mm respectively As per IS: 15652-2006 to be provided as per the requirements on site.

1

-

-

... More
NOTE- (I) Earthing Strips,Running Length of Conductors in the LPS System, Cable Tray and Cable quantities measured based on the as on date Latest drawings received from the Client. It may vary based upon the Site Conditions/Equipment Locations and as per the routing at site by (+/-10%).

-

-

-

... More
(II) Please note that Electrical Contractor need to consider the electrical services layout drawings of overall plant as conceptual drawing only and the electrical contractor need to furnish/prepare the final shop drawing before starting the electrical works and as built drawings after completion of the electrical works as per the site condition and exact shed area machinery/equipment/instrument location layout. Electrical Contractor is duty bound to prepare shop and as built drawings.

-

-

-

... More
RAIN WATER HARVESTING

-

-

-

... More
UPVC Class “3” Pipes (IS:4985) with 100 mm dia latest amendment soil waste and vent pipes jointed with solvent cement inclusive of all necessary specials like bends, tees, offsets, junctions, pan connector, cowls etc., laid under floor/under ceiling/on walls with suitable supports (threaded rods with clamps/ms angles/gripple supports) for the pipes clamps including making bores in masonry / RCC slabs etc., and rendering the bores in cement mortar after laying the pipes and specials curing etc., complete.

256

-

-

... More
RCC Hume Pipes of NP2 class with suitable collars filling the recess at joints of pipes with hemp dipped in hot bitumen or other suitable compound for chalking of joint by jack, setting up of loose space over the collar joints chalked with CM 1:2, finished both ends to a slope of 1:1 including curing, testing of pipes, etc., complete of following sizes:-

-

-

-

... More
200 mm dia

60

-

-

... More
250 mm dia

40

-

-

... More
400 mm dia

16

-

-

... More
ARBORICULTURE

-

-

-

... More
Organic mannuer filling in ground laid in layers not exceeding 15cm thick spread levelled watering for required level and gradient and shapes

200

-

-

... More
Clearing the area removal of weeds root pebbles etc.

120

-

-

... More
Supply and plantetion of Fox tail palm ( Wodyetaib Bifurcate) 9 to 10 ft length including necessay digging and application of fertilizers.

200

-

-

... More
Supply and plantetion of Bouganvilla(dwarf) Hybrid variety 3 x 3ft high including necessary digging and application fertilizers.

100

-

-

... More
FIRE FIGHTINING

-

-

-

... More
CO2 Design, Supply and installation of a high-pressure seamless brand new rechargeable type CO2 cylinder with a water capacity of 68 liters and CO2 capacity of 45 kg, equipped with a master valve and 24 VDC solenoid for both auto and manual operation. The cylinder conforms to IS-72855 standards with a test pressure of 250 Kg/cm2 and a working pressure of 150 Kg/cm2. It holds approvals from BIS and CCOE. Max working pressure: 250 Kg/Cm2., Qty- 68 Nos

1

-

-

... More
Design, Supply and installation of a high-pressure seamless brand new rechargeable type CO2 cylinder with a water capacity of 68 liters, ISI marked, and CCE approved to fill 45 kg of CO2 gas. The cylinder adheres to IS-72855 standards with a test pressure of 250 Kg/cm2 and a working pressure of 150 Kg/cm2. It holds approvals from BIS and CCOE. Max working pressure: 250 Kg/Cm2.,Qty- 748 Nos

-

-

-

... More
Design,Supply and installation of pilot cylinders with pressure actuation, Qty -28 Nos.

-

-

-

... More
Design, supply and installation of CO2 Cylinder Bank Accessories suitable for 45kg capacity CO2 cylinders, the package includes: a seamless Sch.80 pipe manifold made as per ASTM-A-106 Gr.B standards, finished with a P.O Red shade; a frame assembly equipped with holding rods and nuts for cylinder stability, powder-coated for durability with suitable holes provided for anchor fasteners for grouting; and a gas weight monitor fixing rail assembly, also powder-coated with a red shade finish., Qty - 69 Nos

-

-

-

... More
Design, supply and installation of a Continuous Gas Weight Loss Monitor from reputable brands such as UFC, TRIPARULEX, or equivalents, ensuring accurate and reliable monitoring of gas consumption.", Qty - 814 Nos

-

-

-

... More
Design,Supply and Installation of Remote Cylinder Weight Tracking System, Qty- 66Nos

-

-

-

... More
Design,Supply and Installation of CO2 Discharge, Qty - 650 Nos.

-

-

-

... More
Design,Supply and Installation of Non-Return Valve for CO2 Cylinder. Qty - 814 Nos.

-

-

-

... More
Design,Supply and Installation of 1/2" High-Pressure Hose from Cylinder Manifold, Qty - 814 Nos.

-

-

-

... More
Supply and Installation of 1/4" High-Pressure Hose from Valve to Pneumatic Head, Qty- 748 Nos.

-

-

-

... More
Design,Supply and Installation of Primary Adapter for Cylinder, Qty- 66 Nos.

-

-

-

... More
Design,Supply and Installation of Provision of Conventional Heat Detector (Probe Type with FP Junction Box), Qty - 1200 Nos.

-

-

-

... More
Design,Supply and Installation of Gas Release Control Panel with Backup Battery., Qty - 5 Nos.

-

-

-

... More
Supply and Installation of Manual Gas Release Unit - Weatherproof, Qty - 5 Nos.

-

-

-

... More
Supply and Installation of CO2 Discharge Pressure Sensor, Qty - 5 Nos.

-

-

-

... More
Supply and Installation of Safety Outlet for Manifold, Qty - 5 Nos.

-

-

-

... More
Supply and Installation of Hand-operated suppression mechanism-WP, Qty - 5 Nos.

-

-

-

... More
Supply and Installation of auditory alarm device, Qty - 5 Nos.

-

-

-

... More
Supply and Installation of Audible and Visual Alert System., Qty - 5 Nos.

-

-

-

... More
Supply and Installation of Schedule 40 seamless piping system including elbows, tees, reducers, and other fittings., Qty - 10 Nos

-

-

-

... More
Supply and installation of 2 x 1.5 sq mm cu conductor cable with glands., Qty - 10 Nos

-

-

-

... More
Design, Installation, Testing and Commissioning Charges, Qty - 5 Nos

-

-

-

... More
Portable Fire extinguishers for other areas

-

-

-

... More
Supply and Installation of DCP Cartridge type Fire Extinguisher 6Kgs. capacity bearing ISI Mark for Fighting BC Class of Fire. The Extinguisher will be Manufactured Strictly as per IS: 15683 bearing ISI Mark with floor mounting stand. Minimum fire rating should be 6A, 183B with MAP 90% , Qty- 16 Nos.

-

-

-

... More
Supply and Installation of Co2 type Fire Extinguisher 4.5 Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Squeeze Grip type valve with initial Charge as per IS: 15683:2006 specification, bearing ISI Mark with floor mounting stand. With minimum fire rating 55B. Qty - 2 Nos.

-

-

-

... More
Supply and Installation of Co2 type Fire Extinguisher 9Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Squeeze Grip type valve with initial Charge as per IS: 15683:2006 specification, bearing ISI Mark with floor mounting stand. With minimum fire rating 55B, Qty- 36 Nos.

-

-

-

... More
Hydrant network- piping & Accessories

-

-

-

... More
supply and installation of MS pipe 'B' class, complete with requisite fittings, precise cutting, and fabrication as per provided drawings

-

-

-

... More
150 mm dia Approximate , Qty- 300 Mtr.

-

-

-

... More
100 mm dia Approximate , Qty- 180 Mtr.

-

-

-

... More
80 mm dia Approximate , Qty- 90 Mtr.

-

-

-

... More
supply and installation of wrapping and coating solutions tailored for underground pipes with an approximate diameter of 150mm, ensuring long-lasting protection against corrosion and environmental factors, Qty- 300 Mtr.

-

-

-

... More
Supply and Installation of SS Double Hydrant valve 63mm dia coupling ISI mark With nut bolt, flange, gasket, tee, angle, etc. , Qty- 6 Each.

-

-

-

... More
Supply and Installation of SS Single Hydrant valve 63mm dia coupling ISI mark With nut bolt, flange, gasket, tee, angle, etc., Qty- 14 Each.

-

-

-

... More
Supply and Installation of RRL hosepipe 15mtr. Long with male-female coupling winded ISI mark., Qty- 40 Each.

-

-

-

... More
Supply and Installation of Branch pipe with nozzle 63mm dia, ISI mark., Qty- 20 Each.

-

-

-

... More
Supply & fixing of wall mounting swing type first aid fire hose reel with drum (30 Mtr) With "1" Inch Ball valve, Qty- 20 Set.

-

-

-

... More
Supply and Installation of weather proof fire hose cabinet for keeping 2 no. RRL hose & branch pipe standard size, Qty- 20 Each.

-

-

-

... More
Supply and installation of SS four way fire brigade inlet., Qty- 2 Set.

-

-

-

... More
Supply & fabrication of steel support for piping along with wall side include grouting/ anchorfastner., Qty- 1 Tone.

-

-

-

... More
SITC of GM Air Release Valve 25.**Manufacturer certificate with serial number to be provided, Qty- 4400 Nos.

-

-

-

... More
Selection, SITC of High Pressure portable fire pumps ( 1100-1600lpm ) with suitable pressure ( one working + One stand by ) of same capcity two pumps, the cost shall includes the all fittings, valves, control panel built in cable etc one ready made skid pre assembled.,Qty- 1 Set.

-

-

-

... More
FIRE EXTINIGUSHERS

-

-

-

... More
Supply and install in position approved make ABC Stored pressure type Fire Extinguisher 6 Kgs Modular Fire Extinguishers Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher is manufactured strictly as per IS: 15683:2006 with ISI mark. FIRE RATING 4A 55B, Qty- 48 Nos.

-

-

-

... More
supply and installation of 9-liter Water CO2 Stored Pressure Type fire extinguishers, equipped with a controllable discharge mechanism, suitable for Class A fire ratings (2A), and bearing the ISI Mark IS 15683 for assured quality and compliance.", Qty- 12 Nos.

-

-

-

... More
Foam 9 Ltrs capacity Fire Extinguisher for Transformer Yard and DG Yard., Qty- 1 Nos

-

-

-

... More
Supply and install in position approved make Co2 type Fire Extinguisher 4.5 Kgs Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with 1 metre length Wire Braided Discharge hose and horn and Wheel type (ISI Approved) valve with wall bracket and with initial Charge as per IS: 15683-2006specification, bearing ISI Mark. FIRE RATING 21B, Qty- 48 Nos.

-

-

-

... More
FIRE ALARM & DETECTION

-

-

-

... More
Supply, Installation, testing & Commissioning of Microprocessor based Analogue addressable fire alarm control panel. panel shall have below specifications: 1) Combination of 120 Detectors & Devices per SLC loop. 2) expandable up to min. 1loops. 3) Minimum 40 x 4 Characters LCD display. 4) Networkable - Modules shall be considered ( OFC/copper ) 5) Auto Dialer upto 5 numbers. ( vendor shall consider the auto dailer ) 6) Auto Programming Day and Night Mode 7) Enable and Disable function 8) FM Approved. 9) Advanced user friendly programming software including ‘Fuzzy Logic’. Operates on 120 to 220V AC, 60 / 50 Hz. Operating Temperature 0°C- 49°C /95% relative humidity RH (non-condensing) . Built-in Alarm, Trouble, Security, and Supervisory relays, with 24Hrs Normal Condition 1Hrs Alarm Condition battery backup & mounting accessories as per site conditions. Quote rate shall be included required network/communication modules. Scope of work includes cutting the false ceiling, drilling the holes, laying the cables as per site conditions etc.

-

-

-

... More
4Loop

1

-

-

... More
Supply Installation, Testing & Commissioning of Analogue Addressable type Optical Smoke & Heat Detectors(Multisensor) with required mounting base and back box, FM Approved

164

-

-

... More
Supply, Installation, Testing & Commissioning of Addressable pull type Manual call point /resettable which is used for manually trigger a fire alarm suitable for interconnecting to the loop technology directly. ( No break glass type). FM Approved

38

-

-

... More
Supply, Installation, Testing & Commissioning of Sounder cum strobes multi tone sounder. FM Approved

38

-

-

... More
Supply, Installation , Testing & Commissioning of Addressable Control Modules with required battery backup and Power Supply Units. With required back box. FM Approved

12

-

-

... More
Supply, Installation , Testing & Commissioning of Addressable Monitor Modules.(for third party integration) . With required back box. FM Approved

14

-

-

... More
Supply, Installation , Testing & Commissioning of Fault Isolator Module with required back box. FM Approved

12

-

-

... More
Supply& Fixing of Response Indicators, Local Approved

45

-

-

... More
Supply & laying of 2 core x1.5 Sq.mm FRLS Cu conductor Armoured shielded type fire rated low smoke multi-stranded, copper conductor cable.(includes termination and testing of loop into device) approx. quantity only. Actuals as per site conditions. ( for loops & Hooters )

4300

-

-

... More
Supply & laying of 3 core x1.5 Sq.mm FRLS Cu conductor Armoured shielded type Power cable multi-stranded, copper conductor cable.(includes termination and testing of loop into device) approx. quantity only. Actuals as per site conditions. ( for control modules/FZM )

860

-

-

... More
Short wave length laser-Based Absolute Smoke Detection system with 1 pipe inlets, 500 m2 coverage; Wide sensitivity range - 0.001%–20% obs/m; 4 alarm levels ; High efficiency aspirator; Clean air barrier optics protection; Easy to replace dual stage filter with memory; 7Nos of inbuilt potential free relay outputs;supports linear pipe length of 50m per pipe (total 100m) or branched pipe up to 50m per pipe; supports 20 Nos of EN54 Class A sampling points, AutoLearn for automatic setup of alarm threshold, Referencing & Event log; TCP/IP, WiFi & VESDANet connectivity for central monitoring & monitoring of Andriod/iOS tablets/smartphones. The panel shall have Automated Pipe Cleaning technlogy. Approvals-UL, ULC, FM, ActivFire, VdS, CE , EN54-20.

12

-

-

... More
Short wave length laser-Based Absolute Smoke Detection system with 2 pipe inlets, 2000 m2 coverage; Wide sensitivity range - 0.001%–20% obs/m; 4 alarm levels ; High efficiency aspirator; Clean air barrier optics protection; Easy to replace dual stage filter with memory; 7Nos of inbuilt potential free relay outputs;supports linear pipe length of 100m per pipe (total 400m) or branched pipe up to 130m per pipe; supports 80 Nos of EN54 Class A sampling points, AutoLearn for automatic setup of alarm threshold, Referencing & Event log; TCP/IP, WiFi & VESDANet connectivity for central monitoring & monitoring of Andriod/iOS tablets/smartphones.The panel shall have Automated Pipe Cleaning technlogy. Approvals-UL, ULC, FM, ActivFire, VdS, CE , EN54-20.

1

-

-

... More
Short wave length laser-Based Absolute Smoke Detection system with 4 pipe inlets, 6000 m2 coverage; Wide sensitivity range - 0.001%–20% obs/m; 4 alarm levels ; High efficiency aspirator; Clean air barrier optics protection; Easy to replace dual stage filter with memory; 7Nos of inbuilt potential free relay outputs;supports linear pipe length of 100m per pipe (total 600m) or branched pipe up to 130m per pipe; supports 100 Nos of EN54 Class A sampling points, AutoLearn for automatic setup of alarm threshold, Referencing & Event log; TCP/IP, WiFi & VESDANet connectivity for central monitoring & monitoring of Andriod/iOS tablets/smartphones, The panel shall have Automated Pipe Cleaning technlogy. Approvals-UL, ULC, FM, ActivFire, VdS, CE , EN54-20.

1

-

-

... More
Sampling Hole Kit which consist of PVC pipe fitting ( Tee ) with 10mm dia built in hole to suck the air.

234

-

-

... More
PVC/UPVC/CVPC/ABS Plastc End Cap for large bore pipes, 25 mm

41

-

-

... More
EN approved power supply unit with 110/230VAC input and 18 to 29VDC output. The power supply unit has the following indications: OK - Green LED and Fault - Yellow LED, shall be installed at Aspiration panel.

14

-

-

... More
Sampling Pipe - 25mm OD, 18 to 21mm ID smooth bore PVC/UPVC/CVPC/ABS Plastc Pipe

1610

-

-

... More
Software based Air flow calculation shall be run to verify the Transport Time from the farthest sampling point of the zone to Aspiration panel. ( Ensure that the Transport Time shall not more than 120 Sec )

14

-

-

... More
Supply, install, testing, commissioning and configuration of Aspiration system central monitoring station to monitor the all the field aspiration panels at control room which consist of suitable Workstation with 21 inc monitor, key pad, wired mouse pre loaded latest OS, i5 processor, 1TB SSD, 8GB Ram, Pre loaded Central monitoring software, the sofware supports upto 20 field panel and user firendly. The required Ethernet Communication cable with conduit & Network switch from field panels shall be considered.

1

-

-

... More
LIGHTNING PROTECTION SYSTEM

-

-

-

... More
8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination and down conductor system . Cross sectional area of conductor should be 50 mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.034 µm, c.Tensile strength - 178 MPa or N/mm² d. Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2.

370

-

-

... More
Nylon Conductor Holder for Parapet wall for holding 8 mm dia Aluminium alloy round Conductor.

340

-

-

... More
Nylon roof conductor holder for flat roof with concrete block for fixing 8 mm dia Aluminium alloy Solid Round Conductor in the terrace flat surface at every 1 mtr.

30

-

-

... More
Stainless steel 304 Grade Cross Connector for 8 mm dia Aluminium alloy round conductor & 10 mm Copper bonded conductor at cross/Tee junction. Test Parameter a) Mechanical Load b) Electrical Test c) ENvironmental Test Tested for IEC 62561-1

35

-

-

... More
Expansion Joint with connector to compensate the expansion and contraction of 8mm dia Solid Round Al. Conductor during temperature variations. Expansion Joint should be consider at every 20 mtr length of straight horizontal air termination and connected at both the end with use of straight connector conductor.

15

-

-

... More
Supply Installation of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305. Test Parametres: a) Mechanical Load b) Electrical Resistivity c) Environmental Test Tested as per IEC 62561-1

9

-

-

... More
VAT 2mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends (Tappered Type). The rod shall be mounted with stainless steel clamp and fixing accessories . Test Parameter for 2 mtr vertical air terminal a)ELectrical Resistivity b) Tensile Strength c) Condition of Salt Mist Tested as per IEC 62561-2. Test Parametrer for Wall clamp a) Mechanical load as per IEC 62561-1

2

-

-

... More
VAT 2 mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends(Tappered Type). The rod shall be mounted with stone and fixing accessories . Test Parameter for 2 mtr vertical air terminal a)ELectrical Resistivity b) Tensile Strength c) Condition of Salt Mist

5

-

-

... More
VAT 6mtr length of material AlMgSi of diametre ø 40/22/16/10 mm crimped on both the ends(Tappered Type). The rod shall be mounted with stainless steel stand and fixing accessories . Test Parameter: Mechanical Load Test for individual aluminium alloy rods - 120 to 280 N/mm² Salt Spray Test-No sign of corrosion Tested as per IEC 62561-1&2

1

-

-

... More
Stainless steel SS 304 Grade Folding Clamp as per sheet profile for 8 mm dia Aluminium alloy Solid Round Conductor for horizontal Air terminal above metal sheet to meet the requirements for IS/IEC 62305. Test Parameter: a) Mechanical Load b) Environmental Test Tested as per IEC 62561-4

5

-

-

... More
DOWN CONDUCTOR SYSTEM

-

-

-

... More
8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination and down conductor system . Cross sectional area of conductor should be 50 mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.034 µm, c.Tensile strength - 178 MPa or N/mm² d. Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2.

325

-

-

... More
Nylon Conductor Holder for Parapet wall for holding 8 mm dia Aluminium alloy round Conductor.

325

-

-

... More
Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305. Test Parametres: a) Mechanical Load b) Electrical Resistivity c) Environmental Test Tested as per IEC 62561-1 CAPE Type : CJ 8

15

-

-

... More
Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6.

1

-

-

... More
Stainless Steel 304 grade Test Joint with enclosure to interconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor. Test Parameter: Salt Spray Test for test joint plate -No sign of Corrosion Tested as per IEC 62561-1 CAPE Type : TJRRE-G1

14

-

-

... More
EARTHING SYSTEM

-

-

-

... More
10 mm copper bonded Solid Steel Round Conductor with minimum coating thickness 70µm as integrated down conductor. Material should be tested Tensile strength, Electrical Resistance, salt mist, Bend & Adhesion to meet the requirements of IS/ IEC 62305 and IEC 62561-1&2.

100

-

-

... More
Stainless steel SS 304 Grade Conductor Holder for fixing the 8 -10 mm dia round conductor on the wall . Test Parameter: a) Mechanical Load b) Environmental Test Tested as per IEC 62561-4

28

-

-

... More
Supply Installation of CAPE make UL Listed Maintenance Free Copper bonded Earth rod of 3048mm length having the dia of 14.2 mm with copper coating thickness of 254 microns. The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2 & UL 467. Supply Installation of Earth enchancing mineral compound tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7 Supply Installation of Supply of CAPE make Earth rod clamp made for terminating cable. Supply Installation of Connecting point made of stainless steel for terminating 10mm dia copper conductor. Supply Installation of Earth Chamber Inspection Pit made up of Plastic withstand load of 60kN

14

-

-

... More
LIFT Supply, Installation, Testing, Commissioning of Goods lift, 4 stops, encompassing with Capacity: 4 tons Speed: 0.5 meters per second Power Supply: 415 volts, 3 phase AC, 50 Hz Drive System: Single-speed motor with AC Variable Voltage and Variable Frequency Drive (VVVF drive) Compliance: Conforms to IS-14665 standards and amendments, components, safety features, installation process. centre opening stainless steel doors with electric motor-driven mechanism, Sliding stainless steel doors for enhanced durability and safety, Automatic rescue device (ARD) system for emergency situations, 3D infrared sensor integrated into the full height of the door for safety. Simplex automatic and manual dual-controlled operation, Optional attendant mode for manual operation, Built-in announcing system without a handset in the lift car, machine room, and ground floor landing door, Overload protection to prevent exceeding the lift's capacity, Emergency stop button for immediate halting of operation, Fire-resistant construction materials and components, Battery backup system to ensure operation during power outages, Emergency lighting and alarm system for evacuation procedures.

1

-

-

... More
EOT Design, Supply, Installation, Testing and Commissionoing OF double girder EOT crane,20 ton with Long Travel 37210mm with long travel rail size 60 * 40 MS Bright Bar. Of span 17080mm, Height of lift 11000mm, for Indoor location, with class of duty M5, Hoist Speed : 3.8/ 1.3 m/ Min(VDF), Cross Travel Speed: 20/ 5 m/ Min(VDF), Long Travel Speed: 20/ 5 m/ Min(VDF), Hoist Motor: 18.5 KW, Cross travel motor: 0.75 KW * 2Nos, Long travel motor: 1.15 KW * 2Nos, End carraige wheel base 4000mm, Supply voltage 415v, Control Voltage 110v, Crane Weight: 16300kg(apprx weight), Max wheel Load without impact : 14375 kg (Apprx)

1

-

-

... More
WATER COOLER Supply and installation of 2KVA Air Cooled Servo Controlled Voltage Stabilizer(SCVS) with Input: (170-270) V , Output: 230 V , Type of Colling: Air Cooled, Indoor Type: IP 20.

4

-

-

... More
AC PLANT

-

-

-

... More
Supply, Installation, Testing and commissioning of water coolled VFD SCREW Chiller of the capacity net 175 TR at operating conditions as specified with refrigerant R 134a packaged type Water cooled variable frequency drive (VFD) screw chillers ( Part load details as per IPLV & NPLV FOR AHRI CONDITIONS AND ACTUAL CONDITIONS AT CONSTANT CONDENSER WATER TEMPERATURE WITH AHRI RELIF to be provided along with the tender documents) including its drive motors , water cooled Shell & Tube condensors, expansion device , micro processor control with RS-485 port,nessary operational and safety devices, flow switches, victaulic couplings at the following conditions. chilled water inlet temp is 52.8˚ F and outlet temp is 42.8˚ F ,Fouling Factor 0.0005 ft2/h/°F/BTU for Chiller & Condenser water inlet temp 87.44˚F and outlet temp 97.52˚F,Fouling Factor 0.001 ft2/h/°F/BTUas per specification. (2W+1S)- Qty-03

1

-

-

... More
QTY -3(lot) Coordination with Chiller Supplier / Installer for installation, testing and commissioning of WATER AND AIR COOLED CHILLERS CO-ORDINATION - 3 also ensure that interconnections, piping and cabling are carried out as per BOQ and specifications to enable seamless integration between Chillers & low side work- Qty 03 (lot)

-

-

-

... More
Supply, installation, testing & commissioning of CTI/ JCI APPROVED FRP MULTI CELL, INDUCED DRAFT CROSS FLOW COOLING TOWER WITH BASIN with Capacity Flow: 700USGPM (2W+1S) for airconditioning system. Each tower shall be complete with basin, casing, distribution system, filling, louvers, ladder, fan, Motor (IE3/IE4) and other complete accessories as described in the technical specifications. Motor shall be suitable for 415±10% volts, 50 cycles and 3 phase power supply. Tower shall be designed with high efficiency drift eliminators to meet current environmental standards and guidelines for microbial control. Each tower cell must be installed with common cold water basins and water discharge sumps to facilitate maintenance without causing disruption to the other cells in operation.Cooling Tower Selection Parameters shall be as below and It should be possible to hook up with Chiller plant manager system. All necessary hardware and software should be part of the scope and as per the specifications and approved drawings-QTY -3

-

-

-

... More
CHILLED WATER & CONDENSOR PUMPS

-

-

-

... More
Design, Supply, installation, testing and commissioning of centrifugal End Suction Long Coupled Top Discharge Chilled Water Primary Pumps with high efficency (EFF#1) electric drive motor, as per technical specifications (impellers and wearing rings made of bronze, priming funnel and air purging provision with valves and with necessary grouting, foundation bolts, etc.) including customs clearance and transportation to site. Inertia base Foundation for pumps shall be carried out by hvac contractor until or unless stipulated else where otherwise. All pumps shall be mounted with necessary vibration isolators. Each Pump capacity shall be 420 USGPM @ 15 mt. head as per specifications and approved drawings (2working + 1 stand by) - QTY -3

-

-

-

... More
Design, Supply, installation, testing and commissioning of centrifugal End Suction Long Coupled Top Discharge Chilled Water Secondary Pumps( VARIABLE SPEED) with high efficency (EFF#1) electric drive motor, as per technical specifications (impellers and wearing rings made of bronze, priming funnel and air purging provision with valves and with necessary grouting, foundation bolts, etc.) including customs clearance and transportation to site. Inertia base Foundation for pumps shall be carried out by hvac contractor until or unless stipulated else where otherwise. All pumps shall be mounted with necessary vibration isolators. Each Pump capacity shall be 420 USGPM @ 25 mt. head as per specifications and approved drawings (2 working + 1 standby ) -QTY -3

-

-

-

... More
Design, Supply, installation and testing and commissioning of centrifugal End Suction Long Coupled Top Discharge Condenser water Pumps with high efficency (EFF#1) electric drive motor, as per technical specifications impellers and wearing rings made of bronze, priming funnel and air purging provision with valves and with necessary grouting, foundation bolts, etc. including customs clearance and transportation to site. Inertia base Foundation for pumps shall be carried out by hvac contractor until or unless stipulated else where otherwise. All pumps shall be mounted with necessary vibration isolators. Each Pump capacity shall be 700 USGPM @ 15mt. head as per specifications and approved drawings (2working + 1 stand by)-QTY -3

-

-

-

... More
VARIABLE FREQUENCY DRIVES & LOGIC CONTROL PANEL:

-

-

-

... More
Supply, Installation, Testing & Commissioning fo variable speed pumping system comprising of following accessories. The system shall be complete in all respects including electrical components for motor of primary chilled water pumps. Each pump shall have an independent adjustable frequency drive. Common Panel with suitable controller to control 4 Nos. Pumps separately. as per specs and drawing. Including sensor, transmiter, control wiring etc complete in all respect. It shall be also BMS compatible. Panel should be IP 55 Rated. For Secondary chilled water pumps. Variable frequency drive (VFD) : 3Nos Micro processor based pump controller : 1 No Software down loaded in pump controller : Job Control wiring : Lot Variable speed pumping system described above-QTY -1

-

-

-

... More
QTY -1 Supply Installation Testing and Commissioning Dirt separator , it shall be of a solid and robust construction (Mild Steel). It shall be able to remove solid particles upto 5 microns from water at Velocity between 2-3m/s. All connections, fittings and heads shall be of carbon steel. The medium used to de-aerate and remove dirt shall be manufactured of Steel Tube & a mesh made of copper wire. This medium should be non clogging in nature. The flow should not be obstructed by the dirt collected. A Drain valve should be present at the bottom to remove the accumulated dirt without the need of shutting down the operation of the system. The Dirt Separator shall be insulated depending upon its location (outdoor or indoor). The pressure drop on account of the dirt separator shall not exceed 21 kPa at maximum flow of the chilled water system.and also as per the tender Specifications.

-

-

-

... More
PRESSURIZATION SET

-

-

-

... More
Supply, Installation, Testing and Commissioning of Insulated Pressurisation Unit (1000 L)of requisite capacity with necessary makeup, quick fill, drain and over flow connection, valves, fittings, suitable rating pump,expansion vessel (1000 L), necessary pump connection along with valves,stariner and compleate panel etc. The closed expansion tank will be of M.S. construction with interchangeable EPDM-BUTYL rubber membrane. The expansion tank shall be complete with safety relief valve, pressure reducing valve and pressure gauge. The tank will be of pressure rating to suit the system pressure and will be sized to adequately compensate for water expansion due to operating temperature variations. The tank shall be fabricated as per IS 2825-1969 for “non-fired pressure vessels” and the flanges shall be as per IS 6392-1971. For chilled water application, it will be insulated with 50mm thick insulation to the specifications and cladded with 26G-aluminium cladding. The expansion tank shall be supplied along with pressurization unit. Pressurization unit shall be with 2 nos. (1 working + 1 stand by) horizontal/vertical multi-stage pumps of suitable rating & capacity, as indicated hereunder, factory mounted on a steel frame along with interconnected piping, valves, strainer, pressure gauge, pressure transmitter, flow meter to measure the make-up water quantity, control panel with duty cycling and dry-run protection, electrical relays/contactors and interconnecting wiring: Protection - IP55 ,Insulation class - F ,Liquid temperature range - 0°C - 50°C The unit shall be capable of Pressurising the system to the required pressure with suction from a break-tank located at least 1m above pump level. The control unit shall be housed in a metal box, IP 54 protection with BMS compatibility via an RS485 cable interface. All pump's shall be mounted with necessary vibration isolators, etc. as per the specifications and approved drawings -QTY -1

-

-

-

... More
Supply of the chiller plant manager system shall have the capability to monitor and control chillers, primary,Secondary ,condenser water pumps, cooling towers and motorized valves to provide the chiller plant operator with control, monitoring, and management information as per the IO summary and tender spec. Water cooled Chiller's to be controlled - 3 No's No. of primary pumps: 3 No’s No. of Secondary pumps: 3 No’s No. of Condensor pumps : 3 No’s No. of Cooling towers: 3 No’s Management of hydronic units : Yes Regulation on two water circuits : Yes User interface with display and commands : Yes- QTY -1

-

-

-

... More
Automatic Tube Cleaning system :- Supply Installation Testing and Commissioning of Automatic Tube Cleaning system (Ball Type) having common controller for monitoring and operating 80CS for 3 Nos chillers with ancillary components and touch screen controller plc Panel for automatic operation.It shall consist of Ball trap,Ball collector,Ball injection,Collection skid consisting of seperate injection pumpsp with motors,seperate collection pump with motors,necessary electrical operated motorised control valves,control panel with PLC and HMI on the control panel- multicolor seventh touch screen type long end manual ball valves ,pressure gugaes,Cleaning sponge balls etc. qty : 3Sets Chillers ,Supply , Supply Installation Testing and Commissioning HDPE Water tank of suitable capacity not less than 5000Liters ISI Marked( 3 layers,Cylindrical,Vertical with closed top) complete with inlet,Outlet and overflow connection and float valves etc.including GI pIPE medium grade complete with fitting valves etc.for connecting cooling tower sump and storage tank as required and specified.l. Note Necessary Platform for make up water tank and connected pipes and piping shall be dwmed to be included in the rate quoted in above items -QTY -1

-

-

-

... More
AIR HANDLING UNIT

-

-

-

... More
Supply, Installation of double Skin Thermal Break AIR HANDLING UNIT 's With 50 mm Sand witched PUF Insulation, Thermal break profile with 0.8 mm GI inner skin and 0.63 mm GI painted outer skin comprising of Pre filter section with 10 microns washable type of 90% efficiency , CHW Coil sections of min 6row coil ( coil size should be selected for max velocity of 500 fpm across face),2 Row Hot Water Coil complete with necessary Coil drift eliminator of ABS construction, Fan section with plug fan , fan limit load . TEFC high efficency motor, Variable speed drive , vibration isolator, provision for fire damper, fire retardant canvass connection with GI ,powdercoated finish angle flanges on both sides at the outlet of fan, and volume control damper at all the inlet / outlet of AHU, Limit Switch, Emergency Light, Guard for Inspection Door,Commissioning filters set,mixing box as required for connection for return air and fresh air, Starter panel with necessary controls, incoming cable from starter panel to unit , 12-24V Step down transformer for PIBC Valve Actuators, etc. Digital Thermostat with remote sensing element with unit switch on/off control , compatable to the PIBC valve to control the room temperature to be included as per the specifications and approved drawings.

-

-

-

... More
QTY -4(NOS) 7100CFM / 30TR(ASRS ROOM) @ 80mm TSP

-

-

-

... More
QTY -3 (NOS)8350CFM / 30TR(PROVIDER ROOM) @ 80mm TSP

-

-

-

... More
CEILING SUSPENDED UNITS:

-

-

-

... More
Supply, Installation of Double Skin Ceiling suspended Unit with 50 mm Sand witched PUF Insulation, Non Thermal break profile with 0.8 MM GI inner skin and 0.63 MM GI painted outer skin comprising of Pre filter section with 10 microns washable type of 90% efficiency , CHW Coil sections of min 6row coil ( coil size should be selected for velocity not exceeding 500 fpm across face), DIDW forward curved centrifugal Fan belt/ direct driven with TEFC motor, vibration isolator, insulated Stainless steel drain tray, supports, provision for piping connections, Starter panel with necessary controls, incoming cable from starter panel to unit ,12-24V Step down transformer for PIBC Valve Actuators,Digital Thermostat with remote sensing element with unit switch on/off control , compatable to the PIBC valve to control the room temperature to be included, required Fire retardant canvass connections with GI . powdercoated finish angle flanges on both sides, etc. Extended tray should accommodate all valves & PIBC valves, etc. as per the specifications and approved drawings.

-

-

-

... More
QTY -1(NOS)16.0 TR / 2400 CFM@ 50mm TSP .

-

-

-

... More
QTY -4(NOS) 8.0 TR / 3200 CFM@ 50mm TSP .

-

-

-

... More
QTY -1 (NOS) 10.0 TR / 4000 CFM@ 50mm TSP .

-

-

-

... More
QTY -1 (NOS) 12.0 TR / 4800 CFM@ 50mm TSP .

-

-

-

... More
QTY -6 (NOS) 15.0 TR / 6400 CFM@ 50mm TSP .

-

-

-

... More
CASSETTE UNITS:

-

-

-

... More
Design,Supply, installation and testing and commissioning of Chilled water Cassette Units with 3.0TR (4WAY), 3 speed having coil section, blower section, filter section, condesate drain pump, insulated and extended drain tray, supports, copper piping connections&Unions, Incoming cable from MCB/ Isolator to unit , 12-24V Step down transformer for PIBC Valve Actuators, etc. Extended tray should accommodate ball valves, PIBC motorised valves, etc. . Digital Thermostat with remote sensing element with Cassette unit switch on/off control , compatable to the PIBC valve to control the room temperature to be included.Noise level of fan coil unit shall be less than 35 dBA as per the specifications and approved drawings-QTY -1

-

-

-

... More
CALORIFIERS (HOT WATER GENERATOR)

-

-

-

... More
Design, Supply installation testing and commissioning of 30KW capacity galvanised steel shell with removable electric water element of min 30KW, designed for inlet temp of 60deg C and 70 deg C water out let with nessary fittings, valves, mounting brakets with minimum 15 minutes storage as per specification-QTY -6

-

-

-

... More
HOT WATER PUMPS

-

-

-

... More
Design, Supply, installation and testing and commissioning of Horizontal Multistage monoblock Centrifugal pump with necessary grouting, foundation bolts, etc. including customs clearance and transportation to site, testing and commissioning of constant speed hot water pumps. Each Pump capacity shall be 30 USGPM @ 15 mt. head, mounted on frame with factory fitted nessary fittings, valves, pressure guages, header, control panel and expansion tank (100 L) as per specification (1 working + 1 stand by)-QTY -6

-

-

-

... More
HOT WATER PIPES

-

-

-

... More
Supply, Installation, Testing and Commissioning of MS 'C' Class hot water pipe with Ø 50 mm, fittings, flanges, valves,reducers ,sockets for probe meter, support hangers with vibration isolation hanger etc with Supply, Installation, Testing and Commissioning of chilled water pipe insulation with 44mm thick closed cell elastrometric nitrile rubber of density 43 Kg/m3, Thermal conductivity not exceeding 0.035 W/M°K Class 1, fire performance to pass class 1 as per BS 476 part 6& class O as per BS 476 part 7 & use recommended adhesive. the insulation finished with treated woven glass fiber reinforced covering & further finished with 24G Aluminium cladding as per the specifications and approved drawings-QTY -210

-

-

-

... More
AIR DISTRIBUTION SYSTEM:

-

-

-

... More
Supply, Installation, Testing and Commissioning of factory fabricated Box type GSS Ducting ( with minimum 120 Gms /Sqm zinc coating) as per SMACNA/DW standards with splitters,bends, elbows, vanes, supports,neoprene of minimum 6mm thick gasket, duct sealant (to be applied in all corners & joints), nuts, bolts, angle iron flanges, ect. GI full threaded rods hung to minimum 12 mm dia HILTI make anchor fastner as required and Pre painted slotted rail supports, as per the specifications and approved drawings.

-

-

-

... More
QTY -352 24G (0.6 mm thick)

-

-

-

... More
QTY -1028 22G (0.8 mm thick)

-

-

-

... More
QTY -562 20G (1.0 mm thick)

-

-

-

... More
QTY -2255 18G (1.2 mm thick)

-

-

-

... More
INSULATION:

-

-

-

... More
Supply, Installation, Testing and Commissioning Thermal Insulation of Supply air ducting /Return for Indoor with 19mm thick closed cell elastrometric Nitrile rubber with of density minimum 43Kg/m3, FM approved and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and covered with 7 mil thick chemically treated woven glass cloth having density 205+/- 10 g/sqm and affixed using synthetic contact adhesive of approved make and protective coating of starbond 30-36 all as per the specifications and approved drawings -QTY -2200

-

-

-

... More
Supply, Installation, Testing and Commissioning of Under deck insulation type of a 25mm thick non fibrous ,closed cell , Elastometric Nitrile Rubber with factory laminated aluminium foil of density minimum 43 kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7& class O as per BS 476 part 6 and fixed to roof slab using recommended adhesive / SR Fevicol 505 grade and fastened using 26g chicken wire mesh and 2"x2" GI washers and joints sealed with tape as per the specifications and approved drawings - QTY -815

-

-

-

... More
Supply & Installation of Duct Accoustic Insulation (for initial 5 meters )applied inside of the duct work with 10mm thick Open cell Nitrile Rubber fixed using sticker pins and GI washers. Material density minimum of 150 kg/m3 & The material should conform to Class 1 rating for surface spread of Flame as per BS 476 Part 7, as per the specifications and approved drawings-QTY -725

-

-

-

... More
DAMPERS, GRILLES & DIFFUSERS:

-

-

-

... More
Supply, Installation, Testing and Commissioning of Opposed type GI Zero leakage Volume Control dampers with matching flanges of sizes as per specification and approved drawings-QTY -8(SQM)

-

-

-

... More
Supply, Installation, Testing and Commissioning of Fire dampers with fusible links with frame etc for supply. Rated for 2 hours (Dampers should be of wall / duct mounted) as per specification and approved drawings.

-

-

-

... More
QTY -14 (NOS)Up to 0.5 Sqmt

-

-

-

... More
QTY -R/O 0.51 to 1 Sqmt

-

-

-

... More
Supply, Installation, Testing and Commissioning of Extruded Al. Powder coated Continous grill / Discrete grills for supply/ Return air as per the specifications and approved drawings. (Colour to match the false ceiling as per the Client/ Consultant approval)

-

-

-

... More
QTY -75(SQM) 250MM Ht

-

-

-

... More
QTY -4 (SQM)150MM Ht

-

-

-

... More
Supply, Installation, Testing and Commissioning of Extruded Al. Powder coated Diffusers for Supply/ Return air, as per the specifications and approved drawings.(Colour to match the false ceiling as per the Client/ Consultant approval) -QTY -40(SQM)

-

-

-

... More
)Supply, Installation, Testing and Commissioning of Al. Collar dampers, as per the specifications and approved drawings.(Colour to match the false ceiling as per the Client/ Consultant approval) -QTY -58 (SQM

-

-

-

... More
Supply, Installation, Testing and Commissioning of weather proof extruded aluminium powder coated fresh air louver of non vision type of Perforated Al net, VCD etc as per the specifications and approved drawings-QTY -5 (SQMT)

-

-

-

... More
Supply, Installation, Testing and Commissioning of Extruded Al. Powder coated Toilet Exhaust Grills , as per the specifications and approved drawings.(Colour to match the false ceiling as per the Client/ Consultant approval) -QTY -2(SQM)

-

-

-

... More
CHILLED WATER PIPING WITH INSULATION, VALVES AND ACCESSORIES:

-

-

-

... More
INSIDE CHILLED WATER PIPE INSULATION of 32mm thick for inside piping with closed cell elastrometric nitrile rubber of density 43 Kg/m3, Thermal conductivity not exceeding 0.035 W/M°K Class 1, fire performance to pass class 1 as per BS 476 part 6& class O as per BS 476 part 7 & use recommended adhesive / SR Fevicol 505 grade and Insulation covered with 7 mil thick chemically treated woven glass cloth having density 205+/- 10 g/sqm and affixed using synthetic contact adhesive of approved make and protective coating of starbond 30-36 ,as per the specifications and approved drawings.

-

-

-

... More
QTY -50(RM) Ø 300 mm

-

-

-

... More
QTY -160(RM) Ø 250 mm

-

-

-

... More
QTY -120(RM) Ø 200 mm

-

-

-

... More
QTY -130(RM) Ø 150 mm

-

-

-

... More
QTY -80(RM) Ø 125 mm

-

-

-

... More
QTY -300(RM) Ø 100 mm

-

-

-

... More
QTY -440(RM) Ø 80 mm

-

-

-

... More
QTY -200(RM) Ø 65 mm

-

-

-

... More
QTY -140(RM) Ø 50 mm

-

-

-

... More
QTY -280(RM) Ø 32 mm

-

-

-

... More
QTY -320(NOS) Ø 25 mm

-

-

-

... More
Supply, Installation, Testing and Commissioning of balancing (Manual) with Ø 150 mm, matching flanges , bolt, nuts, Nitrile rubber insulation with GC cloth and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with (24G Aluminium cladding for Exposed), all etc., complete as per specifications and approved drawings -QTY -6

-

-

-

... More
Supply, Installation, Testing and Commissioning of butterfly / isolation valve'swith matching flanges , bolt, nuts,Nitrile Rubber insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding for Exposed , all etc., complete as per specifications and approved drawings.

-

-

-

... More
QTY -15(NOS) Ø 200 mm

-

-

-

... More
QTY -8(NOS) Ø 150 mm

-

-

-

... More
QTY -8(NOS) Ø 125 mm

-

-

-

... More
QTY -12(NOS) Ø 80 mm

-

-

-

... More
QTY -24(NOS) Ø 50 mm

-

-

-

... More
QTY -2(NOS) Ø 40 mm

-

-

-

... More
Supply, Installation, Testing and Commissioning of Motorised butterfly valve's (IP55)with Ø 150 mm (chiller), actuator ,mating flanges, bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding, all etc., complete as per specifications and approved drawings-QTY -6

-

-

-

... More
Supply, installation, testing & commissioning of PRESSURE INDEPENDENT BALANCING CUM CONTROL VALVE with spring return , matching flanges,necessary digital thermostat And control wiring bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering etc., complete as per specifications and approved drawings.

-

-

-

... More
QTY -6(NOS) Ø 80 mm (for AHU )

-

-

-

... More
QTY -12(NOS) Ø 50 mm

-

-

-

... More
QTY -1(NOS) Ø 40 mm

-

-

-

... More
Supply, Installation, Testing and Commissioning of Y Strainers consisting of magnetic screen , bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding, all etc., complete as per specifications and approved drawings.

-

-

-

... More
QTY -6(NOS) Ø 150 mm

-

-

-

... More
QTY -6(NOS) Ø 80 mm (for AHU )

-

-

-

... More
QTY -18(NOS) Ø 50 mm

-

-

-

... More
QTY -1(NOS)Ø40 mm

-

-

-

... More
Supply, Installation, Testing and Commissioning of flexible connections (Bellows)suitable for working pressure of PN16. as per the specifications and approved drawings.

-

-

-

... More
QTY -18(NOS) Ø 150 mm (for pumps & CHILLER )

-

-

-

... More
QTY -12(NOS) Ø 80 mm (for AHU )

-

-

-

... More
QTY -24(NOS) Ø 50 mm (for CSU )

-

-

-

... More
QTY -2(NOS) Ø 40 mm (for CSU )

-

-

-

... More
CONDENSER WATER PIPING WITH VALVES AND ACCESSORIES:

-

-

-

... More
Supply, Installation, Testing and Commissioning of MS 'C' Class conforming to IS -1239(pt-1) Equvavalent to BS-1387, Condenser water pipe with fittings, flanges, valves, reducers, sockets for probe meter, support hangers with vibration isolation hanger, including painting, etc for condenser water piping without insulation as per the specifications.

-

-

-

... More
QTY -50(RM) Ø 350 mm

-

-

-

... More
QTY -35(RM) Ø 300 mm

-

-

-

... More
QTY -120(RM) Ø 250 mm

-

-

-

... More
QTY -60(RM) Ø 200 mm

-

-

-

... More
QTY-80(RM) Ø 150 mm

-

-

-

... More
QTY-20(RM) Ø 125 mm

-

-

-

... More
QTY-80(RM) Ø 100 mm

-

-

-

... More
QTY-20(RM)Ø 80 mm

-

-

-

... More
QTY-25(RM) Ø 65 mm

-

-

-

... More
QTY-10(RM) Ø 50 mm

-

-

-

... More
QTY-15(RM) Ø 32 mm

-

-

-

... More
QTY-10(NOS) Ø 25 mm

-

-

-

... More
Supply, Installation, Testing and Commissioning of balancing (Manual) with QTY-6(NOS) 250 mm dia (chiller), matching flanges , bolt, nuts, insulation and suitable for working pressure of PN16. as per the specifications and approved drawings.

-

-

-

... More
Supply, Installation, Testing and Commissioning of Motorised butterfly valve's QTY-3(NOS) (IP55)with actuator ,mating flanges, bolt, nuts, insulation and suitable for working pressure of PN16. , all etc., complete as per specifications and approved drawings.

-

-

-

... More
Supply, Installation, Testing and Commissioning of butterfly / isolation valve's with matching flanges , bolt, nuts, insulation and suitable for working pressure of PN16 as per the specifications and approved drawings.

-

-

-

... More
QTY-12(NOS)250 mm dia ( cooling tower & condenser pumps)

-

-

-

... More
QTY-4(NOS) 200 mm dia ( cooling tower & condenser pumps)

-

-

-

... More
QTY-12(NOS)150 mm dia ( cooling tower & condenser pumps)

-

-

-

... More
QTY-4(NOS)100 mm dia ( Condenser Equiliser Line)

-

-

-

... More
QTY-4(NOS)80 mm dia ( For Flush/Circulation)

-

-

-

... More
QTY-2(NOS)65 mm dia ( For Flush/Circulation)

-

-

-

... More
QTY-7(NOS)50 mm dia ( Make up water & Drain)

-

-

-

... More
QTY-10(NOS)40 mm dia (Cooling Tower Quick Fill /Make Up)

-

-

-

... More
Supply, Installation, Testing and Commissioning of Y Strainers consisting of magnetic screen ,insulation & matching flanges and suitable for working pressure of PN16 ,as per the specifications and approved drawings.

-

-

-

... More
QTY-3(NOS)250mm dia ( Condenser Pumps)

-

-

-

... More
Supply, Installation, Testing and Commissioning of Non return valves with matching flanges , bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding, all etc., complete as per specifications and approved drawings. .

-

-

-

... More
QTY-3(NOS)250 mm ( Condenser Pumps)

-

-

-

... More
Supply, Installation, Testing and Commissioning of flexible connections (Bellows) and suitable for working pressure of PN16 as per the specifications and approved drawings.

-

-

-

... More
QTY-6(NOS)250 mm ( Condenser Pumps )

-

-

-

... More
QTY-4(NOS)200 mm (Condensor unit)

-

-

-

... More
Supply & Installation of other accessories:

-

-

-

... More
QTY-80(NOS)6 inch dia dial type thermometers with thermowell and mounting box. as per the specifications and approved drawings.

-

-

-

... More
QTY-92(NOS) 6 inch dia dial type pressure gauge with isolating gate valve / cock with insulation (Chillers, Pumps , CSU's ) as per the specifications and approved drawings.

-

-

-

... More
Gate valve for drain with insulation as per the specifications and approved drawings.

-

-

-

... More
QTY-10(NOS)Ø 25 mm

-

-

-

... More
QTY-14(NOS)Ø 32 mm

-

-

-

... More
Double float Automatic air vents with QTY-32(NOS) Ø 25 mm as per the specifications and approved drawings.

-

-

-

... More
DRAIN PIPE:

-

-

-

... More
Supply, Installation, Testing and Commissioning of CPVC (Chlorinated Poly Vinyl Chloride) pipes condensate drain piping insulated using 9 mm thick nitrile rubber tubes including fitting and supports as per the specifications and approved drawings.

-

-

-

... More
QTY-150(RM)Ø 25 mm

-

-

-

... More
QTY-100(RM)(Ø 32 mm

-

-

-

... More
QTY-75(RM)Ø 40 mm

-

-

-

... More
HOT WATER SYSTEM WITH VALVES AND ACCESSORIES:

-

-

-

... More
Supply, Installation, Testing and Commissioning of butterfly / isolation valve'swith QTY-30(NOS) Ø 50 mm, matching flanges , bolt, nuts,Nitrile Rubber insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding for Exposed , all etc., complete as per specifications and approved drawings.

-

-

-

... More
Supply, Installation, Testing and Commissioning of Y Strainers consisting of QTY-12(NOS)Ø 50 mm, magnetic screen , bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding, all etc., complete as per specifications and approved drawings.

-

-

-

... More
Supply, Installation, Testing and Commissioning of Non return valves with QTY-12(NOS) Ø 50 mm, matching flanges , bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with 24G Aluminium cladding, all etc., complete as per specifications and approved drawings. .

-

-

-

... More
Supply, Installation, Testing and Commissioning of balancing (Manual) with QTY-12(NOS) Ø 50 mm, matching flanges , bolt, nuts, Nitrile rubber insulation with GC cloth and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering & finished with (24G Aluminium cladding for Exposed), all etc., complete as per specifications and approved drawings.

-

-

-

... More
Supply, installation, testing & commissioning of 3 - WAY MOTORISED VALVE with QTY-6(NOS) Ø 50 mm, spring return , matching flanges,necessary digital thermostat And control wiring bolt, nuts, insulation and suitable for working pressure of PN16. The insulation covered with treated woven glass fiber reinforced covering etc., complete as per specifications and approved drawings.

-

-

-

... More
Supply, Installation, Testing and Commissioning of flexible connections (Bellows) ,QTY-12(NOS) Ø 50 mm suitable for working pressure of PN16. as per the specifications and approved drawings.

-

-

-

... More
Supply, Installation, Testing and Commissioning of Cabinet type/ Circular Inline Ducted Exhaust Fan complete with TEFC Motor with suitable supports and other accessories complete of following capacities .

-

-

-

... More
QTY-8(NOS)700cfm @ 20 mm TSP

-

-

-

... More
QTY-2(NOS)650cfm @ 20 mm TSP

-

-

-

... More
ELECTRICAL WORKS:

-

-

-

... More
Main Panel for Chillers , Pumps & Ahu's:

-

-

-

... More
QTY-1(NOS)Supply, installation, testing and commissioning of Plant room ACB panel of 3 phase 415 V free standing floor mounted made out of 14 G MS sheet after seven tank processes and painted with Powder coating as required , the compartment having cut out of minimum 3mm . the panel shall be for out door application with class protection not less than IP-65 , as per the specifications and approved drawings with earth leakage relay. Incomer : 2100 Amps 4P ACB having SC release and thermal over load element inbuilt with setting range between 40-100% -1 No. Busbar : 2100A TPN Aluminium Busbar-1 Set Out Goings: 3 x 300 Amps MCCB outgoing for Water Cooled chillers, 3 x 100 Amps MCCB outgoing for Cooling Towers, 3 x 40 Amps MCCB outgoing for chilled primary water Pumps (2 W + 1 S) , 3x 40 A MCCB outgoing for Secondary water Pumps (2W + 1 S), 3 x 40 A MCCB outgoing for Condensor water Pumps (2W + 1 S), 1x 32 A MCCB outgoing with starter for Pressurisation Unit, 7x 63 A MCCB outgoing with starter for AHU, 1 no. spare feeder with 400 A MCCB. 1 no. spare feeder with 40 A incoming , 1 no. spare feeder with 32 A incoming . Above MCCBs should have in built SC release and thermal over load element with setting range between 40 - 100% as per standard, 32 A & above outgoing modules shall also include power contactor, O/L relay with single phase preventer, On/Off push buttons, On/Off trip indication lamps, Rotary auto /manual selector switch. All out going feeders will have 96 X 96 mm taut band ammeters with appropriate CT ratio - 4 Nos 4 NO/NC contacts. Auxiliary contactor 2 Nos. each per MCCB 0-500 V digital voltmeter with selector switch. 0-400 A digital ammeter of size 96 X 96 mm and selector switch with CT ratio. 400/5A, Class 1 accuracy and 15A burden. The MCCB shall consist of load manager for measuring Voltage, Amp's, power factor, frequency,energy consumption , hours of operation and fault trip indication

-

-

-

... More
Supply, Installation, Testing and Commissioning of following size 1.1 KV Grade Aluminum / Copper conductor XLPE insulated PVC sheathed armoured cable and shall be laid on cable tray with all installation materials. the cable shall conform to IS 7098 / part-I.

-

-

-

... More
QTY-80(RM)3.5C x 240 sq.mm. - (Aluminum) (for Chillers)

-

-

-

... More
QTY-250(RM)3C x 10 Sq.mm. - (Copper) (for Cooling tower ,chilled water Primary , Secondary Pumps & Condensor Pump)

-

-

-

... More
QTY-40(RM)3C x 6 Sq.mm. - (Copper) (for pressurisation unit).

-

-

-

... More
Supply, Installation, Testing and Commissioning of POWER CABLING of QTY-120(RM)3C x 2.5 sq.mm copper cable, for each IDU to be suitably laid in PVC conduit as per site requirement.

-

-

-

... More
ELECTRICAL TERMINATIONS WITH DOUBLE COMPRESSION GLANDS / LUGS:

-

-

-

... More
Supply, Installation, Testing and Commissioning of QTY-3(SET) 3.5C x 240 sq.mm. Al armoured (For CHILLERS)

-

-

-

... More
Supply, Installation, Testing and Commissioning of QTY-9(SET) 3C x 10 sq.mm. Al armoured (Copper) (For PUMPS )

-

-

-

... More
Supply, Installation, Testing and Commissioning of QTY-1(SET)3C x 6 sq.mm. Al armoured (Copper) (For PRESSURISATION UNIT ).

-

-

-

... More
Supply, Installation, Testing and Commissioning of REMOTE CABLING QTY-100(RM)of 4C x 1 Sq.mm. copper cable between each IDU & its wired remote to be suitably laid in PVC conduit as per site requirement.

-

-

-

... More
EARTHING SYSTEM:

-

-

-

... More
Supply, Installation, Testing and Commissioning of GI flat QTY-50(RM)50 mm x 6 mm.

-

-

-

... More
Supply, Installation, Testing and Commissioning of single core Green PVC insulated QTY-50(RM)2.5 sq.mm. wire.

-

-

-

... More
CABLE TRAY:

-

-

-

... More
Supply, Installation, Testing and Commissioning of powder coated GI Cable tray of perforated type QTY-120(RM)150mm wide with GI cover (both 2mm thick) including suitable powder coated MS supports as per the specifications and approved drawings.

-

-

-

... More
Supply, Installation, Testing and Commissioning of powder coated GI Cable tray of perforated type QTY-100(RM)300mm wide with GI cover (both 2mm thick) including suitable powder coated MS supports as per the specifications and approved drawings.

-

-

-

... More
ENGINEERING CHARGES:

-

-

-

... More
QTY-1(LOT)Engineering, documentation, shop drawings, technical writeup, logic development, graphics development, installation, testing and commissioning

-

-

-

... More
THIRD PARTY COMMISSIONING CHARGES:

-

-

-

... More
QTY-1(LOT)Supply installation and testing of third party commissioning.

-

-

-

... More
QTY-13(NOS)Supply,Installation,Testing and Commissioning of Duct Heaters to control the RH,with DP air flow Switch and safety Thermostats, Digital RH Control panel Wall mounted Control Panel Supplied along with Duct Mountable RH sensor,Flange In type DUCT Cross section /Duct Heater for Ceiling Suspended Units.

-

-

-

... More
Subtotal

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.