Military Engineer Services Tender
... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Solar Installation and Products
Electrical Works
Eprocure
Opening Date7 Feb 2025
Closing Date28 Feb 2025
Tender Amount₹ 49,65,000
Costs
EMD
₹ 99,300Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_696889_1Tender No
8564 (A) MISC E/M WORKS AND REPAIR/ REPLACEMENT/ MAINT OF LT ELECTRICAL DISTRIBUTION SYSTEMTender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Removing excavated material to a distance n.exc 50m and depositing where directed at level not exceeding 1.5m above the starting point all as specified & directed.
24.47
-
-
... More
M & L for Reinforced concrete pipes of dia 150 mm 2 nos half round (each of 1 RM long for bottom and top ) and before laying excavated area shall be levelled all as specified and directed.
808.5
-
-
... More
M & L GI Tubes, 'light grade', galvanised, with all fittings laid in trenches of size 50 mm dia.
30
-
-
... More
M & L GI Tubes, 'light grade', galvanised, with all fittings laid in trenches of size 80 mm dia.
30
-
-
... More
Cutting of road/hard standing and making good with PCC (1:2:4) type B 1 using 20mm graded stone aggregate complete all as specified.
1.5
-
-
... More
M & L for fixing of Orange electrical conduit underground HDPE/DWC pipe of size 80 mm dia including all necessary clamping and fixing arrangement complete all as spd and dircted by EIC.
200
-
-
... More
Taking out existing worn out/old PVC insulated cable in 3.5 core of 185 /240 sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete in all respect and as directed at site.
147
-
-
... More
Taking out existing worn out/old PVC insulated cable in 3.5 core of 70/95/120/150 sqmm to 35 Sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete in all respect and as directed at site.
339.5
-
-
... More
Taking out existing worn out/old PVC insulated cable of 4/10/16/25/35/50 sqmm any type of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete in all respect and as directed at site.
861
-
-
... More
Maint and augmentation by Supply, laying, testing and commissionnig of LT cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete 10 sqmm 2 core.
300
-
-
... More
-- do-- as per item no. 13 above but of size 16 sq mm 2 core
150
-
-
... More
-- do-- as per item no. 13 above but of size 16 sq mm 4 core
150
-
-
... More
-- do-- as per item no. 13 above but of size 25 sq mm 3.5 core
200
-
-
... More
-- do-- as per item no. 13 above but of size 35 sq mm 3.5 core
150
-
-
... More
-- do-- as per item no. 13 above but of size 50 sq mm 3.5 core
130
-
-
... More
-- do-- as per item no. 13 above but of size 70 sq mm 3.5 core
150
-
-
... More
-- do-- as per item no. 13 above but of size 95 sq mm 3.5 core
100
-
-
... More
-- do-- as per item no. 13 above but of size 120 sq mm 3.5 core
120
-
-
... More
-- do-- as per item no. 13 above but of size 150 sq mm 3.5 core
115
-
-
... More
-- do-- as per item no. 13 above but of size 185 sq mm 3.5 core
130
-
-
... More
-- do-- as per item no. 13 above but of size 240 sq mm 3.5 core
80
-
-
... More
Supply, laying, testing and commissionnig of LT cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete 4 sqmm 3 core.
150
-
-
... More
M & L for MCCB 63/100 Amps, 16KA, TP 415 Volts with adjustable thermal and fixed magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
3
-
-
... More
M & L for MCCB 125 Amps, 25KA, TP 415 Volts with adjustable thermal and fixed magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
2
-
-
... More
M & L for MCCB 200 Amps, 25KA, TP 415 Volts with adjustable thermal and adjustable magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
2
-
-
... More
M & L for MCCB 160 Amps, 25KA, TPN 415 Volts with adjustable thermal and fixed magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
2
-
-
... More
M & L for MCCB 250 Amps, 25KA, TPN 415 Volts with adjustable thermal and adjustable magnetic setting with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
2
-
-
... More
M & L for MCCB 400 Amps, 36KA, TPN 415 Volts with adjustable overload and adjustable shortcircuit with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
2
-
-
... More
M & L for MCCB 630 Amps, 50KA, TPN 415 Volts with adjustable overload and adjustable shortcircuit with cable entry arrangements, lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete including taking down the old U/S MCCB.
2
-
-
... More
M&L for trimming of branches of trees touching LT/HT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height 9 mtr and above and carrying the depositing where directed not exceeding 50 mtr. Note :-the contractor shall be solely responsible for ensurig all safety measures during execution of the job.
50
-
-
... More
M& Labour for removal of vegetation in and around the MES substation, 4 pole structure, 2 pole structure like grass , shurbs, small plants. The contractor shall be solely reonsible for ensureing all safety meassures during the execution of the job. The contractor shall complete the work within one (01) hour to minimize the inconvenience to the users and sufficient man power and eqpt will be provided to complete the job within the specified timeframe.
60
-
-
... More
Taking down old UNSV panel any type and shape/size and supply , installation, testing and commissioning as in repair Outdoor type LT panel board cubical and outdoor canopy type with double door, floor mounted CPRI approved with MS angle iron base frame made out of 40x40x6mm angle, with angle iron Stand made out of 50x50x6 mm thick having 4 Nos legs of 2 feet height of size as required at site,grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates for fixing panel board with and including necessary fixing arrangements,totally enclosed dust and vermin proof, front opening with locking arrangement, suitable for AC 415V, 3 phase, 50 Hz system, Red, Yellow, Blue and Black coloured insulated Aluminium bus bar of suitable size to carry 450 amps four Nos of suitable length and internal wiring with aluminum strip of suitable size duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer of any tint and marking wiring circuits, complete all as specified and as directed duly comprising of the following accessories :-
1
-
-
... More
Continued to Item No 35 Above
(a) Voltmeter flush mounted 0-500 V square digital type -01 No.
(b) Ammeter flush mounted 0-250A, CTs operated, square digital type-01 Nos.
(c) Phase indicating lamp set (RYB) industrial LED type-01 Set. (d) MCCB 250 Amp FP 36 with adjustable thermal setting (with spreader terminal kit) - 01 NOs.
(e) MCCB 160 Amp FP 25 with adjustable thermal setting (with spreader terminal kit) - 01 NOs. (f) MCCB 63 Amp FP 25 with adjustable thermal setting (with spreader terminal kit) - 05 NOs (g) SPN 63 Amp - 02 NOs
-
-
-
... More
Taking down old UNSV panel any type and shape/size and supply , installation, testing and commissioning as in repair Outdoor type automatic power factor correction (APFC) panel of capacity 50 KVAr panel board cubical and outdoor canopy type with double door, floor mounted CPRI approved with MS angle iron base frame made out of 40x40x6mm angle, with angle iron Stand made out of 50x50x6 mm thick having 4 Nos legs of 2 feet height of size as required at site,grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates for fixing panel board with and including necessary fixing arrangements,totally enclosed dust and vermin proof, front opening with locking arrangement, suitable for AC 415V, 3 phase, 50 Hz system, Red, Yellow, Blue and Black coloured insulated Aluminium bus bar of suitable size to carry 450 amps four Nos of suitable length and internal wiring with aluminum strip of suitable size duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer of any tint and marking wiring circuits, complete all as specified and as directed and minimum comprising of the following accessories :-
1
-
-
... More
Continued to Item No 36 Above
(a) 100A 3P 25kA MCCB TM Release (Adjustable Thermal & Adjustable Magnetic) (with spreader terminal kit) - 01
(b) VAF Meter, 3Ph/1Ph, Acc. CL: 0.5, 3 Digit 3 line Display, CT Ratio Selectable upto 6000/5A AC, Parameters: Avg. V(L-L), Avg. V(L- N), Hz, Load Hr/ No Load Hr., RPM, Voltage: 230V AC, Size: 96x96, Model: AVF-19D -multispan or equalient makes - 01
(c) 200/SA Acc.Cl: 1 10VA Tape Wound Ring Type Current Transformer -01 Nos
(d) Phase indicating lamps set (RYB) industrial LED type (e) 12 Stage Intelligent Power Factor Controller (1CT), Type: IPFC CS 1001, Voltage: 90/550V AC, (f) 6 Amp, 3 Way Multi Step Switchs with off
(g) ON Delay Timer, Time Setting: 0.3sec - 30hrs, Voltage: 240V AC /24V AC/DC, Contact: 1 C/O
(h) 16A Auxiliary Contactor, Coil: 240V AC, Aux. Contact: 2NO+2NC,Type: HGR 22 Havells or equivalient (j) Different size heavy duty, square/cylinder type 440 V AC capacitor
(k) 6 Amp 1 P 10 KA MCB
-
-
-
... More
Man and material for Load Distribution and Balancing at LT Panel/Feeder Pillar any type and size. , the job focuses on checking and redistributing the load at an outdoor LT feeder pillar or large panel using XLPE cables. Work works include measuring of the load on each phase using a digital clamp meter and load analyzer, Identify unbalanced loads or overloaded phases, redistribute load from one phase to another, disconnect and reconnect equipment or circuits from feeder pillar terminals or busbars as needed, ensure balanced load on each phase. Any insulation tape, connectors, and cable ties for securing connections use of Clamp meter, multimeter, load analyzer, and phase sequence tester use by the contractor will be the part of this job, precaution like De-energize the distribution Panel while making connections other electrical safety measures will be the reasonability of contractor, The whole job will be completed in a time bound manner complete all as directed by Engr-in-charge.
30
-
-
... More
Taking down old UNSV Panel any type and shape/size and supply , installation, testing and commissioning as in repair Outdoor type LT panel board cubical and outdoor canopy type with double door, floor mounted CPRI approved with MS angle iron base frame made out of 40x40x6mm angle, with angle iron Stand made out of 50x50x6 mm thick having 4 Nos legs of 2 feet height of size as required at site,grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates for fixing panel board with and including necessary fixing arrangements,totally enclosed dust and vermin proof, front opening with locking arrangement, suitable for AC 415V, 3 phase, 50 Hz system, Red, Yellow, Blue and Black coloured insulated Aluminium bus bar of suitable size to carry 450 amps four Nos of suitable length and internal wiring with aluminum strip of suitable size duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer of any tint and marking wiring circuits, complete all as specified and as directed duly comprising of the following accessories :-
1
-
-
... More
Continued to Item No 38 Above
(a) MCCB 200 Amp 4, Pole 36 KA - 01
(b) MCCB, AC, 415 Volt, 100 Amps breaking capacity 25 kA at 415 volt, 4 pole - 01
(c) MCCB, AC, 415 Volt, 63 Amps breaking capacity 25 kA at 415 volt, 4 pole -02
(d) MCB, AC, SPN 63 Amp - 02
(e) Digital Voltmeter with selecor switch range 0 to 500 volt (f) Digital Ammeter with selectro switch range 0 to 100 Amp
(g) Indicator Lamps
-
-
-
... More
Man and material for Load Distribution and Balancing at Indoor DB (any type and size ), the job focuses on checking and redistributing the load at all the DBs including measuring of the load on each phase using a digital clamp meter and load analyzer, Identify unbalanced loads or overloaded phases, redistribute load from one phase to another, disconnect and reconnect equipment or circuits from DBs or busbars as needed, ensure balanced load on each phase. Any insulation tape, connectors, and cable ties for securing connections use of Clamp meter, multimeter, load analyzer, and phase sequence tester use by the contractor will be the part of this job, precaution like De-energize the distribution Panel while making connections other electrical safety measures will be the reasonability of contractor, The whole job will be completed in a time bound manner all as directed by Engr-in-charge.
70
-
-
... More
Material and labour for servicing and repairing LT distribution panel installed at various substation, including dismantling incomming & outgoing cable connections from feeders/ switch gears, S&F heat shrinkable cable sleeves and insulation taping properly on cable. Replacement of cable end terminals (lugs) of appropriate size, replacement of U/s Nut bolts washers etc., replacing unserviceable indicator lamp R Y B, repairing to panel wiring including Panel door repair, replacement of door hinges, locking system etc. repairing/replacement of ampt meter, voltmeter, indicator lamp will be included in the job. Reconnecting all elect connections, earthing connections checking throughly and made all feeders serviceable. All electrical safety measures will be the reasonability of contractor, The whole job will be completed in a time bound manner all as directed by Engr-in-charge.
20
-
-
... More
M & L for preparing old painted surfaces by scraping and removing old paints, rust etc. from LT Panel/feeder pillar, painting in one coat of redoxide with two coats of synthetic enamel paint Complete all as specified and directed.
20
-
-
... More
M & L in repairs for cable jointing kit for 1.1 KV grade cable for outdoor, heat shrink type, joint complete with jointing material and accessories suitable for 4/3.5 core XLPE, armoured, Aluminium conductor cable of following sizes:-
-
-
-
... More
25 to 50 sqmm
10
-
-
... More
70 to 120 sqmm
6
-
-
... More
150 to 185 sqmm
4
-
-
... More
240 to 300 sqmm
4
-
-
... More
Taking down old UNSV panel any type and shape/size and supply , installation, testing and commissioning as in repair Outdoor type automatic power factor correction (APFC) panel of capacity 125 KVAr panel board cubical and outdoor canopy type with double door, floor mounted CPRI approved with MS angle iron base frame made out of 40x40x6mm angle, with angle iron Stand made out of 50x50x6 mm thick having 4 Nos legs of 2 feet height of size as required at site,grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates for fixing panel board with and including necessary fixing arrangements,totally enclosed dust and vermin proof, front opening with locking arrangement, suitable for AC 415V, 3 phase, 50 Hz system, Red, Yellow, Blue and Black coloured insulated Aluminium bus bar of suitable size to carry 450 amps four Nos of suitable length and internal wiring with aluminum strip of suitable size duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer of any tint and marking wiring circuits, complete all as specified and as directed and minimum comprising of the following accessories :-
1
-
-
... More
Continued to Item No 43 Above
(a) 250A 3P 25kA MCCB TM Release (Adjustable Thermal & Adjustable Magnetic) (with spreader terminal kit) - 01
(b) VAF Meter, 3Ph/1Ph, Acc. CL: 0.5, 3 Digit 3 line Display, CT Ratio Selectable upto 6000/5A AC, Parameters: Avg. V(L-L), Avg. V(L- N), Hz, Load Hr/ No Load Hr., RPM, Voltage: 230V AC, Size: 96x96, Model: AVF-19D -multispan or equalient makes - 01
(c) 250/SA Acc.Cl: 1 10VA Tape Wound Ring Type Current Transformer -01 Nos
(d) Phase indicating lamps set (RYB) industrial LED type (e) 12 Stage Intelligent Power Factor Controller (1CT), Type: IPFC CS 1001, Voltage: 90/550V AC, (f) 6 Amp, 3 Way Multi Step Switchs with off
(g) ON Delay Timer, Time Setting: 0.3sec - 30hrs, Voltage: 240V AC /24V AC/DC, Contact: 1 C/O
(h) 16A Auxiliary Contactor, Coil: 240V AC, Aux. Contact: 2NO+2NC,Type: HGR 22 Havells or equivalient (j) Different size heavy duty, square/cylinder type 440 V AC capacitor
(k) 6 Amp 1 P 10 KA MCB
-
-
-
... More
Supply, Errecting and fixing of true Vertical position steel tubular swaged pole complete with coat iron base plate, finial taper plug, bolt, nuts and screw,weld and reduced section and logitudional weld Seam through out entire length of pole including 2 coats of black bituminious paint through out intrnely and externely up to planting depth and remaining exterior portion of pole with two caot of aluminium paint over a coat of red oxide as specified type 410 SP 31 (9.00 Mtr long) incl taking down old unserviceable pole all as specified and directed at site. NOTE - Excavation and Earth work and PCC in foundation shall be measured and paid seprately.
2
-
-
... More
Testing and fault locating of LT underground cable with the help of cable fault locating machine at site including excavated with in the area of faulty cable all as directed.(Note:- The machine for locating of fault will be arranged by the contractor .The quoted rate is included for the fault locating machine. Necessary excavation , earthwork etc.)
10
-
-
... More
M&L for earthing for sub station equipments (Transformer, lightning arrestor and feeder pillar box) complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of equipments etc at the other, earth strip encased in and including 40mm bore GI medium grade pipe with all fittings from top of electrode to body of equipment fixed with and including 40 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work , etc.complete all as specified and shown in electrical plate No 3 of SSR Pt-I. Note : 1. Refilling of the earth pit shall be carried out with black cotton soil. 2. GI strip 32 x 6 mm & GI protection pipe upto 7.5 m length will be measured under this item.
8
-
-
... More
Supply and fixing GI strip 32 x 6 mm for extension of earth and connected to equipment or panel complete all as specified and directed by Engineer-in-Charge.
40
-
-
... More
M & L for Earthing complete with Copper earth plate electrode 6mm thick of size 600x600x3.15 mm buried directly and vertically in ground with top edge of the plate not less than 2.25 mtr from GL, connected with strip 20x3 mm all as shown in Plate No-3, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx50mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 50 mm dia light grade GI tubing for protection of Strip , charcoal and salt in alternate 150mm thick layers around Copper earth plate, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion
4
-
-
... More
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
4
-
-
... More
Taking down old UNSV Panel any type and shape/size and supply , installation, testing and commissioning as in repair Outdoor type LT panel board cubical and outdoor canopy type with double door, floor mounted CPRI approved with MS angle iron base frame made out of 40x40x6mm angle, with angle iron Stand made out of 50x50x6 mm thick having 4 Nos legs of 2 feet height of size as required at site,grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates for fixing panel board with and including necessary fixing arrangements,totally enclosed dust and vermin proof, front opening with locking arrangement, suitable for AC 415V, 3 phase, 50 Hz system, Red, Yellow, Blue and Black coloured insulated Aluminium bus bar of suitable size to carry 450 amps four Nos of suitable length and internal wiring with aluminum strip of suitable size duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer of any tint and marking wiring circuits, complete all as specified and as directed duly comprising of the following accessories :-
1
-
-
... More
Continued to Item No 50 Above
(a) MCCB, AC, 415 Volt, 160 Amps breaking capacity 25 kA at 415 volt, 4 pole -01 Nos
(b) MCCB, AC, 415 Volt, 63 Amps breaking capacity 25 kA at 415 volt, 4 pole - 03 Nos
(c) MCB, AC, SPN 63 Amp - 04 Nos
(f) Digital Voltmeter with selecor switch range 0 to 500 volt (g) Digital Ammeter with selectro switch range 0 to 100 Amp
(h) Indication lamp as per required
-
-
-
... More
Taking down old UNSV panel any type and shape/size and supply , installation, testing and commissioning as in repair Outdoor type LT panel board cubical and outdoor canopy type with double door, floor mounted CPRI approved with MS angle iron base frame made out of 40x40x6mm angle, with angle iron Stand made out of 50x50x6 mm thick having 4 Nos legs of 2 feet height of size as required at site,grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates for fixing panel board with and including necessary fixing arrangements,totally enclosed dust and vermin proof, front opening with locking arrangement, suitable for AC 415V, 3 phase, 50 Hz system, Red, Yellow, Blue and Black coloured insulated Aluminium bus bar of suitable size to carry 450 amps four Nos of suitable length and internal wiring with aluminum strip of suitable size duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer of any tint and marking wiring circuits, complete all as specified and as directed duly comprising of the following accessories :-
2
-
-
... More
Continued to Item No 51 Above
(a) MCCB, AC, 415 Volt, 160 Amps breaking capacity 25 kA at 415 volt, 4 pole - 01 Nos (b) MCB TPN, 4 pole , AC, 415 Volt, 63 Amps breaking capacity 10 KA - 05
(c) MCB, AC, SPN 63 Amp - 06
(d) Digital Voltmeter with selecor switch range 0 to 500 volt (e) Digital Ammeter with selectro switch range 0 to 100 Amp
(f) Indicator Lamps
-
-
-
... More
Material and labour for disconnecting the Electric & Water connection of the Desert Cooler incl taking down from its existing location removal of unserviceable side panel, Top cover W/Tank side support, grill regulator etc. Scratching old paint with sand paper complete cleaning inner & outer surfaces of the Desert Cooler body to make the surface smooth and painting the inner surfaces & Grills with two coats of black anticorrosive paint and outer surfaces with two coats of alluminium/ hammerton paint over one coat of primer paint of 1st quality with spray machine and including checking the servicibility of Fan and submersible (little ) pump , selector switchs etc., and fixing the D/Cooler at its original place including oiling & Greasing and making electric & water connections and testing the same complete all as specifid and directed by Engineer-in-Charge.
Note :- 1. Labour charges for fixing of defective spare parts shall deemed to be included in unit rate quoted. Replacement of defective spares will be measured & paid separately under relevant items.
6
-
-
... More
Supply and fix as in repairs Capacitor 4 Mfd complete all as specified and directed by Engineer-in-charge.
4
-
-
... More
Supply and fix as in repairs Cooler Pad set of Three of existing size and type complete all as specified and directed by Engineer-in-charge.
6
-
-
... More
Supply and fix as in repairs Selector Switch of existing type & make for D cooler with Knob complete all as specified and directed by Engineer-in-charge.
3
-
-
... More
Supply and fix as in repairs Front Show grill as per exisitng size type and make at site complete all as specified and directed by Engineer-in-charge.
3
-
-
... More
Supply and fix as in repairs PVC Pipe 1/2 " with Elbow plastic as per exisiting length set of three complete all as specified and directed by Engineer-in-charge.
6
-
-
... More
supply and fix as in repairs Wooden ply of size 6mm thick and sheet size 3’x6’ water proof for desert cooler fixing of desert cooler/window AC complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
Supply and fix as in repairs Blades for Cooler motor fan as per existing size and make complete all as specified and directed by Engineer-in-charge.
4
-
-
... More
Disconnecting the mains and Taking out the existing unserviceable cooler fan motor and supply, fixing and testing new cooler fan motor as exiting capacity single phase 240 volts of existing make including reconneting the electric mains and testing complete all as specified and directed by the Engr-in-charge.
2
-
-
... More
Disconnecting the mains and Taking out the existing unserviceable cooler Water lifitng pump submersible and supply, fixing and testing new cooler Water lifting pump heavy duty single phase 240 volts of existing make including reconneting the electric mains and testing complete all as specified and directed by the Engr-in-charge.
4
-
-
... More
Removal of ceiling/Wall mounted fan after Disconnecting the power supply to the fan,Taking apart the fan from its mounted position and fix it to othe location by adjusting or extending electrical wires ensuring wires are insulated using electrical tape or connectors, Ensuring the fan blades are balanced for smooth operation, reconnecting the switch to control the fan complete all as spd and directed by EIC.
250
-
-
... More
Disconnecting and taking down and opening the ceiling fan of size 1200/1400 mm sweep carefully dismantling complete for servicing by cleaning the bearing/bush by cleaining solution and replacing the split pin and unserviceable items like bearing, bushes, rubber real, condenser, flexible cable, canopy, etc., assembling Ceiling fan and refixing in the original place connection and testing complete all well complete all as specified and directed by Engineer-in-Charge. Note- Replacement of unserviceable items will be measured and paid under relevant items.
2316
-
-
... More
Supply and Fixing ball bearing of existing size for 1200/1400 mm sweep complete all as per installed shape and size.
650
-
-
... More
Supply and Fixing gun metal bushes of existing size & make for 1200/1400 mm sweep ceiling fan complete all as specified and directed by Engineer-in-Charge.
400
-
-
... More
Supply and Fixing of condenser 2.5/3 Mfd for ceiling fan/exhaust fan complete all as specified and directed by Engineer-in-Charge.
890
-
-
... More
Supply and Fixing of canopy of existing size & make for 1200/1400 mm Sweep ceiling fan complete all as specified and directed by Engineer-in-Charge.
100
-
-
... More
Supply and fix as in repairs of ceiling fan clamp assembly complete with nut, bolt, washer, u clamp and rubber reel etc of existing size & suitable for 1200/1400mm sweep ceiling fan complete all as specified and directed by Engineer-in-Charge.
100
-
-
... More
Supply and Fixing of PVC 3 core Cord Flexible copper insulated cable 24/0.2mm size Black/Grey colour complete all as specified and directed by Engineer-in-Charge.
300
-
-
... More
Disconnecting and taking down the Exhaust fan & wall mounted fan/Air circulator of size 300/380/450 mm sweep carefully dismantling complete for servicing by cleaning the bearing/bush by cleaining solution and replacing the unserviceable items like bearing, condenser, flexible cable, etc., assembling Exhaust fan and refixing in the original place connection and testing complete all as specified and directed by Engineer-in-Charge. Note;- Replacement of unserviceable items will be measured and paid under relevant items saparately.
445
-
-
... More
S&F Exhaust fan AC single phase 230 volts for size 300 mm sweep, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed inluding removing and dismentaling and given as sch of credit to contractor
10
-
-
... More
Supply and Fixing ball bearing and Bush of existing size for Exhaust fan/wall mounted fan 300 /380/450 mm sweep complete all as specified
150
-
-
... More
Material and labour for Collecting the burnt ceiling fans including blades of any make from AGE E/M dismantling removing the burnt winding and rewinding of ceiling fan 1200/1400 mm sweep with super enameled copper conduct winding wire of same gauge and wight insulating, varnishing, baking, including wornout bearing/bush greasing assembling and fixing the same and testing at site complete all as specified and directed by Engineer-in-Charge. Note- Any transportation of unsv fans to civil workshop if required is deemed to be included in the job.
450
-
-
... More
Supply and fix as in repairs of ceiling fan down rod GI pipe of 15 mm bore, duly arrangement of hole and cutting of pipe etc of size 6 Feet long complete all as spd and directed.
30
-
-
... More
S&F Ceiling Fan AC single phase 230 volts for size 1200 mm sweep, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV fan any type and size and and given as sch of credit to contractor
60
-
-
... More
Material and labour for Collecting the burnt Exhaust fans including blades of any make from AGE E/M store yard/ site removing the burnt winding and rewinding of Exhaust Fan/wall mounted fan of size 280/300mm sweep complete with super enameled copper conduct winding wire of same gauge and wight insulating, varnishing, baking, including wornout bearing/bush greasing assembling , and after repairing fixing and testing of ex fan at site complete all as specified and directed by Engineer-in-Charge. Note- Any transportation of unsv Ex fans to civil workshop if required is deemed to be included in the job.
200
-
-
... More
Material and labour for Preparing the faded surfaces of ceiling fan size 1200/1400 mm sweep with soap/ soda, painting with DUCO paint of approved tint by one coat of spray painting as specified and directed by EIC.
400
-
-
... More
S&F Exhaust fan AC single phase 230 volts for size 450 mm sweep, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV ex fan any type and size and given as sch of credit to contractor
1
-
-
... More
Material and labour for Collecting the burnt Exhaust fans including blades of any make from AGE E/M store yard/ site taking out to reputed work shop dismantling removing the burnt winding and rewinding of Exhaust Fan/wall mounted fan/aircirculator of size 450 mm sweep complete with super enameled copper conduct winding wire of same gauge and wight insulating, varnishing, baking, including wornout bearing/bush greasing assembling and transporting the same and fixing and testing at site complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Material and labour for disconnecting from the electric mains and Taking down opening and inspection of storage type water heater of size 25ltrs/50 Ltrs capacity and descaling with dilute hydrochloric acid, checking for water tightness of the inner tank, cable continuity, thermostat of setting at 70 degree C checking fusible plug, base assembly, stop cock including replacement of indicator lamp, rubber PVC gasket washers reassembling, refixing and reconnection the electric connections at old place and replacing unserviceable bolts and nuts, cementing work including hydraulic pressure testing with hard operated hydraulic pump complete after repair including spray painting of one coat with DUCO paint of approved in after preparation of surface.
Note : (a) Replacement of unserviceable items like heating element, Indicator lamps, thermostat, stop cock, PVC Hot and cold pipes will be measured & paid separately as supply only. (b) Labour charges for replacing the unsv spares, disconnection and reconnection of water and electric connections shall be deemed to be included in unit rate quoted for this items .
209
-
-
... More
Supply and fix as in repairs Heating element (round/ triangular) including rubber washer/PVC gasket of the following size 1.5KW of existing type & make complete all as specified and directed by Engr-in-Charge..
100
-
-
... More
Supply and fix as in repairs Thermostat for geyser of capacity upto 50 ltrs capacity of existing type & make complete all as specified and directed by Engr-in-Charge..
30
-
-
... More
Supply & fix Electric Storage water heater of capacity 25 Ltr , 230 V energy efficient complete all as specified and directed by Engineer-in-charge. Including fast nut, bolt, washe complete and removing and dismentaling of old UNSV electric storage water heater any type and size and given as sch of credit to contractor
4
-
-
... More
Supply and fix as in repair Rubber Gasket for Inner Tank of capacity upto 25 Ltrs of existing type & make complete all as specified and directed by Engr-in-Charge..
80
-
-
... More
Supply and fix as in repair Air release Valve for 25/50 Ltrs capacity of existing type & make complete all as specified and directed by Engr-in-Charge..
50
-
-
... More
Removing of Old leakage geyser tank and supply and fixing of 25 ltr storage water heater tank as per existing shape and type complete all as specified and directed by Engr-in-Charge..
10
-
-
... More
Removing of Old leakage geyser tank and supply and fixing of 50 ltr storage water heater tank as per existing shape and type complete all as specified and directed by Engr-in-Charge..
4
-
-
... More
Supply and fix as in repairs safety valve of existing type and complete all as specified and directed by Engr-in-Charge.
10
-
-
... More
Supply and fix as in repairs CP Stop Valve 15mm dia of existing type complete and make all as specified and directed by EIC.
30
-
-
... More
Supply & fix Electric Storage water heater of capacity 50 Ltr , 230 V energy efficient complete all as specified and directed by Engineer-in-charge. Inluding fast nut, bolt, washe complete and removing and dismentaling of old UNSV electric storage water heater any type and given as sch of credit to contractor
1
-
-
... More
Material and Labour for Disconnecting from mains and Dismantling the unserviceable gyeser base assembly (syphon system) and replacing the new base assembly of existing size & make with rubber gasket for 25 Ltrs capacity (6/8 hole) all as spd and directed by EIC.
50
-
-
... More
Material and Labour for Disconnecting from mains and Dismantling the unserviceable gyeser base assembly (syphon system) and replacing the new base assembly of existing size & make with rubber gasket for 50 Ltrs capacity (6/8 hole) all as spd and directed by EIC.
10
-
-
... More
Supply and fix as in repairs Indicator Lamps for Geyser of capacity 25/50 Ltr existing type complete all as specified and directed by Engr-in-Charge..
50
-
-
... More
Supply and fix as in repairs PVC connections 15 mm size with PTMT nuts of up to length 600 mm length (for hot and cold water inlet and outlet ) complete all as specified and directed by Engr-in-Charge.
100
-
-
... More
supply and and fix as in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron/GI pipe 25 mm dia all as specified and directed
5
-
-
... More
supply and fix as in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron/GI pipe 20 mm dia all as specified and directed
2
-
-
... More
Supply and fix self adhesive printed sticker of vinyal sheet and of size 10 x 3 cm with written letter GE ( C) Pune all as specified and directed.
400
-
-
... More
Supply and fix as in repairs hot water GI pipe duly insulated with glass wool and aluminium cladding 20 mm bore incl connection with solar water heater to tape point and fixing with MS clamp nut bolt etc complete all as spd and directed by EIC.
50
-
-
... More
Repairing of Solar Water heating system (Tubelor rod collector) based on direct transfering of heat thermosyphon cirulation, non pressurised system of capacity 100 to 200 LPD with suitable electric backup including accessories complete all as existing type and size all as specified and directed
5
-
-
... More
supply and fix as in repairs of Solar Water heating system Tubelor rod collector of capacity 58mm x 1800 Dia evacuted class tubes used in solar water heater all as per existing type and size complete all as specified and directed
30
-
-
... More
Replaement of Tubelor rod collector based on direct transfering of heat for 100 to 500 LPD solar water heater (ETC) as per existing shape and size complete all as specified and directed
5
-
-
... More
Supply and fix as in repairs repair of washer (exterior/interior type) of Solar water heating system complete as per existing shape and size.
20
-
-
... More
Replacement of Thermostate for 100 to 500 LPD solar water heater 2000 watt, 35 to 75 deg C, 230 volt single phase complete all as specified and directed
2
-
-
... More
Supply and fix as in repairs of solar water heating element with thermostat 3 KW incl electric connections complete all as specified and directed by Engr-In-charge
5
-
-
... More
supply an fix as in repairs 200 LPD Technoz Spark solar waer heater PC Zing coated tank inner tank sheet 2.5mm, thick and high glass epoxy coating suitable for hard water and borewell water complete all as per existing make and type. The work include installation, removing the old solar panel, installation, commissioning and testing complete all as spd and directed by EIC.
1
-
-
... More
S&F wall fan single phase 230 volts for size 400 mm sweep, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV wall fan any type and size and and given as sch of credit to contractor
2
-
-
... More
Supply and fix as in repairs Heating element (round/ triangular) including rubber washer/PVC gasket of the following size 2 KW of existing type & make complete all as specified and directed by Engr-in-Charge..
70
-
-
... More
Supply and fix as in repairs of ceiling fan down rod GI pipe of 15 mm bore, duly arrangement of hole and cutting of pipe etc of size 30 cm long complete all as spd and directed.
30
-
-
... More
Supply and fix as in repairs of ceiling fan down rod GI pipe of 15 mm bore, duly arrangement of hole and cutting of pipe etc of size 60 cm long complete all as spd and directed.
30
-
-
... More
S&F Exhaust fan AC single phase 230 volts for size 200 mm sweep Plastic body along with louvers, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV ex fan any type and size and taken in sch of credit.
4
-
-
... More
Supply and fix as in repairs of ceiling fan down rod GI pipe of 15 mm bore, duly arrangement of hole and cutting of pipe etc of size 4 Feet long complete all as spd and directed.
40
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%