Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date26 Jun 2024
Closing Date23 Jul 2024
Tender Amount₹ 49,99,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cleaning of PVC/RCC water storage tank in low and high rising buildings(G+14) by mechanical high pressure spray and remove all foreign matter completly and soaking out the water/dirt with a high pressure wet vaccum pump and removing spoils out side of MD land and complete all as specified and as directed by Engineer-in-charge . Note: Rate include the painting of two coats of enamal paint with visible colour about date of cleaning and due date for cleaning complete all as specified.

-

-

-

... More
OH Tank of capacity 5000 Litres

200

-

-

... More
OH Tank of capacity 3000 Litres

80

-

-

... More
OH Tank of capacity 10000 Litres

9

-

-

... More
OH Tank of capacity 15000 Litres

5

-

-

... More
OH Tank of capacity 2000 Litres

150

-

-

... More
OH Tank of capacity 1000 Litres

20

-

-

... More
Cleaning the vegetation including grass, bushes small trees and all vegetation growth complete including uprooting of bushes and small trees around the installation/sump/OH reservoir, valve chamber etc. filling the rough holes with earth and levelling the surfaces by removing all debris to a distance n.exc.50m complete all as specified and directed.

900

-

-

... More
Supply/Fixing in repair/replacement of internal steel water tubing with CPVC pipes SDR 11 & PlainCPVC SDR 11 fittings in wall and shafts including necessary saddling and and work to be done in high rise building up to 15 th floor short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces including fittings such as nipple, union, socket, elbow, bends, tee, adopter e.t.c complete all as specified and directed by Engineer-in-charge of the followingsize:-

-

-

-

... More
20 mm Nominal outside dia

400

-

-

... More
25mm Nominal outside dia

280

-

-

... More
Supply & Fixing in repairs Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc with Fe 410 -W (Gde- E- 250) including making paint with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Note:Contractor should survey each quarter in old and new navy nagar and highly rusted angle should be change accordingly.

450

-

-

... More
Material and labour for bacteriological and chemical analysis of water sample at govt approved lab (Iso 9001:2008) including collecting sample from pumphouse/Md accn/OTM using labed owned sample jar and testing every month all directed and specfied by Engineer-in-charge

90

-

-

... More
Checking of over head tanks of any capacity, making arrangement of mosquito proofing of the tank from overflow side with new GI tank nipples, socket, barrel nipple, elbow, MS wire net, locking the existing tank cover to avoid entry of lizards, mosquitos inside the tank, tightening of all inlet and out let connections to make the tank no leaking of water complete including painting with white colour paint on base coat and writing the letters of black colour of the following details all as specified and directed :- (a) Date of cleaning (b) Date of Next due (c) Tank capacity

270

-

-

... More
M&L for cleaning and sterilization of inside surface of RCC/ Steel Underground/semi underground/Over head/Sedmentation/clear water sumps of capacity UG sump reservoir 12,00,000 ltrs capacity using seven stage water tank sterilization as under :- (a). First Stage : Drain out the water by using exit valve or high capacity dewatering system. (b). Second stage : Cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical (Test certificate of TERBAC-65/INOXI-60/NB -69 from Govt laboratory mentioning suitability for sterilization should be submitted before sterilization) and scrubbing the walls of the tanks. (c). Third strage : Fresh water cleaning by high speed jet pump. (d). Fourth stage: First bacteria screening is sterilization by using TERBAC-G5/ Inohor-5/NB-10 brannded halogen compound (Test certificate of TERBAC-65 Inohor -51 /NB10 from Govt laboratory mentioning suitability for sterilization should be submitted before sterilization). (e). Fifth stage: Cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage :Second bacteria screening and sterilizing by using ultra violet ray ejector covering 360 degree within the tank for killing all suspended bacteria. 2.00 Each Job 150000.00 1.02 (g) Seventh stage : Cleaning and third bacteria screening to sterilize the floor of the water tank using TERBAC G-65 (Test certificate of TERBAC-65 from Govt laboratory mentioning suitability for sterilization should be submitted before sterilization) complete all as specified & directed. NOTE :- The quoted rate is deemed to include for the following :- (i) All cleaning staff shall wear safety helmets, gumboots, safety belts when entering the tanks. (ii) Safety beltsshall be invariabily worn during climbing of stage mounted tanks & getting down in UG sump. (iii) Safety googels shall be worn during spraying of TERBAC-65 & G-65 1.03

8

-

-

... More
All as per item No.10 above but UG sump reservior 90,000 ltrs capacity

8

-

-

... More
All as per item No.10 above but UG sump reservior 2,18,000 ltrs capacity

4

-

-

... More
All as per item No.10 above but UG sump reservior 2,38,000 ltrs capacity

4

-

-

... More
All as per item No.10 above but UG sump reservior 3,63,000 ltrs capacity

2

-

-

... More
All as per item No.10 above but UG sump reservior 1,35,000 ltrs capacity

4

-

-

... More
All as per item No.10 above but UG sump reservior approximately 16,00,000 liters

2

-

-

... More
All as per item No.10 above but UG sump reservior of approximately 14,00,000 liters

2

-

-

... More
Supply/Fixing in repair/replacement of steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note (1)Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the same with new GI pipe in short piece or full length.

-

-

-

... More
15mm bore

290

-

-

... More
20 mm bore

220

-

-

... More
25 mm bore

290

-

-

... More
40 mm bore

90

-

-

... More
50mm bore

80

-

-

... More
80mm bore

270

-

-

... More
Supply and fix in repairs in existing line, gun metal gate valve with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc, work will be executed up to 15 th floor in high rise buildings complete all as specified of following sizes :-

-

-

-

... More
15 mm bore

24

-

-

... More
20 mm bore

8

-

-

... More
25 mm bore

24

-

-

... More
40 mm bore

8

-

-

... More
50 mm bore

5

-

-

... More
80 mm bore

12

-

-

... More
S& F in repair 3-layer PP-R Polypropylene random copolymer) pipes green and blue colour SDR 7.4 11 UVstablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors or shaft of building up to G+15 all specfied and directed by Enginner-in-charge of following sizes:- etc.

-

-

-

... More
16 mm

120

-

-

... More
20 mm

120

-

-

... More
25 mm

110

-

-

... More
40 mm

30

-

-

260

-

-

... More
75 mm

60

-

-

... More
S& F in repair 3-layer PP-R Polypropylene random copolymer) gate valve with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified of following sizes :- etc Note: Work will be executed in building upto G+14 flors

-

-

-

... More
20 mm

20

-

-

... More
25 mm

15

-

-

... More
40 mm

3

-

-

... More
50 mm

8

-

-

... More
63 mm

9

-

-

... More
Excavation in trenches not exceeding 1.5 mtr wide not exceeding 1.5 mtr in depth and getting out in soft/loose soil all as specified.

40

-

-

... More
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil all as specified.

35

-

-

... More
Removing excavated material to a distance exc 250 M but n.exc 500 M and depositing where directed all as specified.

5

-

-

... More
Supply and fix in repair bronze pressure reducing valve suitable for 25 mm bore GI pipe with diaphram cover, spring clamps, cast iron body scatting and adjustable screws and stop valve of chromium plated carbon steel strainer, screw of stain less steel for domestic water supply, suitable for inlet pressure as per IS-7939, including GI pipe connection as required, the work to be carried out from G+14 floor on plain wall with necessary bamboo scaffolding complete all as specified and directed by Engineer-in-Charge.

20

-

-

... More
Dismantling of existing connection and taking out pressure reducing valve of size 25 mm bore cleaning servicing and refixing at existing location in high rise buildings (G+14) including provision of fittings, I.e. union, elbow, bend, nipple, etc. complete to make the line functional all as specified. Note:- (a) All safety measures shall be taken by the worker/plumber while carrying out the work. (b) Rate of scaffolding shall be included in the quoted rate.

37

-

-

... More
Supply and fix in repair brass float valve (ISI marked) high pressure with polythelene float (flat) and fly nut complete screwed for GI pipe 15mm bore including necessary GI fittings such as elbow, reducer, nipple etc.

145

-

-

... More
All as per item No 20.00 above but for GI pipe 20 mm bore

20

-

-

... More
All as per item No 20.00 above but for GI pipe 25 mm bore

20

-

-

... More
All as per item No 20.00 above but for GI pipe 40 mm bore

30

-

-

... More
Taking out existing unserviceabe FRP and supply & fix lid cover for PVC water storage tank complete with accessories for closing and locking arrnagement suitable for 5000 Ltrs as approved BMC.

30

-

-

... More
Taking out existing unserviceabe FRP and supply & fix lid cover for PVC water storage tank complete with accessories for closing and locking arrnagement suitable for 3000 Ltrs as approved BMC.

25

-

-

... More
Taking out existing unserviceabe FRP and supply & fix lid cover for PVC water storage tank complete with accessories for closing and locking arrnagement suitable for 1000/2000 Ltrs as approved BMC.

20

-

-

... More
Taking down GI tubing fixed to wall at location cleaning and refixing the same with clamping by suitable size of MS clamp, nut, bolt, washers on wall/floor/shaft of bldg including provision of necessary fitting in high rise building (G+14 stories) for the following:- (a) All safety measures shall be taken by the worker/plumber while carrying out the work. (b) Rate of scaffolding shall be included in the quoted rate.

-

-

-

... More
15 mm bore

390

-

-

... More
20 mm bore

350

-

-

... More
25 mm bore

550

-

-

... More
40/50 mm bore

180

-

-

... More
S&F in repairs PVC water storage Tank with cover (minimum three layers), ISI marked, pure anti microbail round type and making connections including replacement of new GI fittings i.e. tank nipple, washers, float valves and Gate valves and Pipes for connecting the existing Inlet/delivery lines, testing complete all as specified and directed for the following capacity :- Note :- Gate valves and GI pipe only shall be paid under relevant item of Schedule 'A' remaining items shall be deemed to be included in the item rate.

-

-

-

... More
5000 Ltr capacity

9

-

-

... More
3000 Ltr capacity

3

-

-

... More
2000 Ltr capacity

10

-

-

... More
1000 Ltr capacity

3

-

-

... More
Supply, Installation in repair, Testing & Commissioning of Motor Actuated Butterfly Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 80 mm dia with appropriate bracket/mounting arrangement including two Nos limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status In built Serial / USB communication Port In built data logger with memory In built SD Card Space Heater Mounting ::Extended type with universal joint for installation 18 -24 inches above ground level with angle mounting including raising of existing chamber if required. Make: EMTORK / HASEL HOFENER / RITETORK /SIEMENS/ HONEY WELL

9

-

-

... More
Supply and fixing in repairs, Installation, Testing & Commissioning of Motor Actuated Ball Valve (with wheel for manual operation) consisiting of suitable single phase Actuator and ball valve of size 50 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure complete all as specified and directed. SpecificationSupply and fixing eatures Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Material of Ball: Stainless Steel Limit Switches : 02 Nos.For open and close status Mounting :Direct on valve Make: EMTORK / HASEL HOFENER /SIEMENS/ HONEY WELL/RITETORK

8

-

-

... More
Supply and fixing in repairs, Installation, Testing & Commissioning of Motor Actuated Ball Valve (with wheel for manual operation) consisiting of suitable single phase Actuator and ball valve of size 40 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure complete all as specified and directed. SpecificationSupply and fixing eatures Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Material of Ball: Stainless Steel Limit Switches : 02 Nos.For open and close status Mounting :Direct on valve Make: EMTORK / HASEL HOFENER /SIEMENS/ HONEY WELL/RITETORK

5

-

-

... More
Supply and fixing in repairs, Installation, Testing and Commissioning of Float type Point Level Sensor with the following specifications; Type: Magnetic Magnet: Ring type Switch: Reed Switch (Epoxy sealed) Connecting Cable: Teflon Make: RECKTRONIC DEVICES AND SYSTEMS / TECHTROL / CRYSTAL

30

-

-

... More
Supply and fixing in repairs, Installation, Testing and Commissioning of OFC Cable to be pulled over head and duly fastened/attached to a PVC coated messenger wire / stay wire of gauge either with the required clamps of suitable size not more than 3 feet apart or with a web between the OFC and messenger wire along with endplates at both ends of the suspended cable complete all as specified and directed. (a) 6F Single mode OFC suitable for outdoor networking applications (i) 6 Fibers type single mode, wavelength 1310, Attenuation 0.38/km (ii) Outer jacket of HDPE sheath (iii) Jelly Filled Core (iv) Wrapped with Corrugated Steel Tape (v) Armoured with a pair of Steel Wire for rigidity (vi) Anti Termite and rodent repellent (vii) Water Proof and moisture resistant

120

-

-

... More
Supply and fixing in repairs, Installation of PVC Coated Suitable Dia GI messenger wire / stay wire of gauge either with the required clamps of suitable size not more than 3 feet apart or with a web between the OFC and messenger wire along with endplates at both ends of the suspended cable complete all as specified and as directed.

120

-

-

... More
Supply & Fixing in repairs of 4C x 1.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper cable on wall/ laying in trench complete all as specified and as directed

130

-

-

... More
Supply & Fixing in repairs of 6C x 1.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper cable. on wall/ laying in trench complete all as specified and as directed.

120

-

-

... More
Supply and fixing in repairs, Installation Testing & Commissioning of direct acting type release solenoid valve for air release during priming; with follwing specifications : Size: 10 mm, Pressure rating: 10 kg / sq. cm. Type: Normally closed

5

-

-

... More
Supply and fixing in repairs, motor actuated ball valve suitable for 25 mm GI pipe for priming of pump including all necessary GI fittings, testing and commissioning with following specifications: Size: 25 mm Pressure rating: 10 kg / sq. cm.

5

-

-

... More
Supply, Installation in repair, Testing & Commissioning of pressure Transmitter with following specification including necessary power pack for supply of DC : Power supply: 10-36 V DC Process connection: G ½ “ Enclosure: whether proof IP 65 Process temperature: -30 to 120 celcius Accuracy: 0.25 % Make: Danfoss / Siemens / E & H

5

-

-

... More
Opening of valve chambers, cleaning of grass/earthing materiale inside and perimeter of the chamber, servicing of valves, replacement of gland packings, re-fixing of gate of valve in proper position, painting of valves, chamber covers, repairing of hinges complete all as specified and directed

20

-

-

... More
Dismantle the existing damaged glow sign board complete from the entrance gate of Pump House and remove from site. Supply & installation Glow Sign board made out of PGI sheet 1 mm thick fixed with transparent PVC acrvlic sheet cover of thickness 2.5 mm, of colour as directed with letters and digits of approx size 25 x 10 CM (Appx 42 Nos) of colour as directed, fixed with and including 18 watts, 240 Volt LED tube light fitting with rods as required at site( @ 2 sqm per one LED fitting) connecting with existing electrical point using 2 core PVC insulated, 1.5 Sqmm PVC insulated and PVC sheathed stranded copper conductor cable of suitable length with switch, fixing the sign board on GI pole/building using necessary fixing arrangements viz clamps, nuts, bolts and washers and welding , excavation and PCC work all as specified and directed. Note :1. Size of sign board and colour will be decided by the department as per the site requirement. 2. GI Pole shall be used for fixing of sign shall only be measured and paid separately under relevant item of Sch 'A'. Remaining items are deemed to be inclusive in the item rate.

20

-

-

... More
Supply and fixing in repair CI butterfly valve 100 mm dia PN 1.6 any position/location including all flange joint with rubber or fiber board gaskets, bolts, nuts, washers, welding etc complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing in repair CI butterfly valve 150 mm dia PN 1.6 any position/location including all flange joint with rubber or fiber board gaskets, bolts, nuts, washers, welding etc complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fixing in repair CI butterfly valve 250 mm dia PN 1.6 any position/location including all flange joint with rubber or fiber board gaskets, bolts, nuts, washers, welding etc complete all as specified and directed by Engr-in-Charge.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.