Military Engineer Services Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Feb 2025
Closing Date12 Mar 2025
Tender Amount₹ 1,48,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing in repair bracket for street/security light fitting made of GI pipe 25 / 40 mm light grade 1.2 m long bend to shape including two Nos of clamps nuts and bolt as required including taking down old bracket complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
M&L in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 25 x 4 mm including taking down old strip complete all as specified and directed be Engr in Charge.

800

-

-

... More
Material and labour for refixng of Old uprooted lightening arrestor strips including saddling of strips with suitable saddles and nails all as directed at site by Engineer - in - Charge.

1500

-

-

... More
Supply and fixing 1x 50 sqmm copper conductor with 0.5 mm thick PVC sheathed cable including taking down old cable complete all as specified and directed.

550

-

-

... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators,sockets,light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc

990

-

-

... More
Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC Casing caping of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes/ modular boxes surfacing on wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed by Engr in Charge.

-

-

-

... More
(a) One light point controlled by one switch SP one way.

200

-

-

... More
(b) One ceiling fan point controlled with one 5A switch

50

-

-

... More
(c) One exhaust fan point controlled with one 5A switch

30

-

-

... More
(f) One bell point controlled by one bell push 5 Amps.

10

-

-

... More
(d) One 3 pin socket outlet 5Amps on independant board.

300

-

-

... More
(e) One 3 pin socket outlet 5Amps on same board with other switches.

250

-

-

... More
Material and Labour point wiring complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC casing caping of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 2.5 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed by Engr in Charge.

150

-

-

... More
Supply and fixing Modular Switch, 6Amp, One way, 1 module complete all as specified and directed by Engr in Charge.

830

-

-

... More
Supply & fixing Modular Switch , 16Amp, One way, 1 module, ISI marked complete all as specified and directed.

150

-

-

... More
Supply & fixing Modular type bell push , 6Amp, 1 module, ISI marked complete all as specified and directed by Engr in Charge.

20

-

-

... More
Supply & fixing Bell electric AC 230Volt single pole musical type, ISI marked complete all as specified and directed by Engr in Charge.

150

-

-

... More
Supply and fixing support function blank plate single, 1 module complete all as specified and directed.

10

-

-

... More
Supply and fixing Modular type, electronic fan regulator (5 step), 450 Watts, 230 volts, 2 module complete all as specified and directed .

85

-

-

... More
Supply and fixing ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified.

280

-

-

... More
Supply and fixing Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module.

500

-

-

... More
Supply and fixing Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed complete all as specified and directed by Engr in Charge.

300

-

-

... More
Supply and fixing Modular white cover plate with Frame 2 Module complete all as specified and directed.

50

-

-

... More
Supply and fixing Modular white cover plate with Frame 3 Module complete all as specified and directed.

300

-

-

... More
Supply and fixing Modular white cover plate with Frame 4 Module complete all as specified and directed.

100

-

-

... More
Supply and fixing Modular white cover plate with Frame 6 Module complete all as specified and directed.

100

-

-

... More
Supply and fixing Modular white cover plate with Frame 8 Module complete all as specified and directed.

60

-

-

... More
Supply and fixing Modular white cover plate with Frame 12 Module complete all as specified and directed.

50

-

-

... More
Supply and fixing Modular metal flush box 2 module including cutting, chassing, filling putti & good make of distrubed surface and matching with existing colour complete all as specified and directed.

50

-

-

... More
All as per item No 32.00 but metal flux box 3 module.

300

-

-

... More
All as per item No 32.00 but metal flux box 4 module.

100

-

-

... More
All as per item No 32.00 but metal flux box 6 module.

60

-

-

... More
All as per item No 32.00 but metal flux box 8 module.

100

-

-

... More
All as per item No 32.00 but metal flux box 12 module.

50

-

-

... More
Supply and fixing Polymer extruded channel, with opaque diffuser for glare free light 1x18/20 WH (min 100 lumen /watt) 04 feet long accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size with all accessories complete all as specified and directed.

1500

-

-

... More
Supply and fixing Polymer extruded channel, with opaque diffuser for glare free light 1x10 WH 02 (min 100 lumen /watt) feet long accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size with all accessories complete all as specified and directed.

550

-

-

... More
Material and labour for cleaning all ldust filling cavities with filler, prepartation of surfaces, painting of ceiling fans , in situ with one coat of synthetic enamel paint by spray painting complete all as specified and directed.

450

-

-

... More
Material and labour for cleaning all ldust filling cavities with filler, prepartation of surfaces, painting of Exhaust fan , in situ with one coat of synthetic enamel paint by spray painting complete all as specified and directed by Engr in Charge.

100

-

-

... More
M & L for rewinding of unserviceable ceiling fans lof size 1200/1400 sweep with approved copper enamalled wire of suitable guage, varnishing, replacing existing split/ quarter pins, rubber bush, capacitor 2.5 Mfd and including taking down and refixing in exsiting position and testing complete all as specified and directed by Engr in charge.

800

-

-

... More
M & L for rewinding of unserviceable exhaust fans lof size 225/300/450/630mm sweep with approved copper enamalled wire of suitable guage, varnishing, replacing existing nut bolts pins, rubber bush, capacitor , bearing ,m bush, frastner etc and including taking down and refixing in exsiting position and testing complete all as specified and directed by Engr in charge.

100

-

-

... More
Supply & fixing in repair Switch 5 Amps piano type, single pole 230 Volts complete all as specified and directed

50

-

-

... More
Supply & fixing in repair switch socket combination multipurpose for 3/2 pin 5 Amps flush type ISI marked complete all as specified and directed.

150

-

-

... More
Supply & fixing in repair switch socket combination multipurpose 2 in 1 for 3 pin 15 Amps & 3pin 5 Amp controlled by one switch flush type complete all as specified and directed.

150

-

-

... More
Supply & fixing in repair stepped type electronic fan regulator flush type 450 Watts, complete ISI marked all as specified and directed

50

-

-

... More
Supply and fixing in repair Capacitor 2.5Mfd complete all as specified and directed.

400

-

-

... More
Supply and fix in repair LED lamp suitable for 14 watts (min 120 lumen /watt), 240 volts, single phase, 50 Hz, Lumen 1450 AC supply complete all as specified and directed.

1400

-

-

... More
Material and Labour in repair for Lamp holder, PVC /Polycarbonate type with cord grip cap suitable for pendant fittings complete all as directed by Engineer-in-Charge.

450

-

-

... More
Supply and fixing GI strip 32/6 for building earthing and sadling in high rise bldg wall (G+ 15 floor), cable trunch, building cable duct from the LT panel to DB up to height of 50 RM from ground and fix properly all as directed by Engr-in-Charge

550

-

-

... More
Supply & Fixing 3 inch / 4 inch long 12 mm to 20 mm dia fastner including bolt , pin , washer complete all as specified and directed by engineer in charge.

100

-

-

... More
Supply and fixing plastic water tank top cover double lock of capacity of tank 500 Ltr to 2000Ltr design in round shape to provide complete coverage and protection to the water tank and equipped with a closing lid mechanism ensuring secure sealing and preventing contaminants from entering the water complete all as specifed and directed by Engr in Charge.

45

-

-

... More
Supply and fixing plastic water tank top cover double lock of capacity of tank 3000 Ltr to 10000 design in round shape to provide complete coverage and protection to the water tank and equipped with a closing lid mechanism ensuring secure sealing and preventing contaminants from entering the water complete all as specifed and directed by Engr in Charge.

25

-

-

... More
Taking down unserviceable and Supply and fixing CPT Cirprotec CPT-L ESE lightning rod with stainless steel body Type Advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186-96, working on the principle of Early Streamer Emission technology which will offer Level 1 protection for up to 30 Mtrs Mtrs radius when mounted on the RCC concrete base on Building at a height of 4.5 mtrs from the place to be protected complete all as directed by Engr-in Charge.

6

-

-

... More
Taking down Old Unserviceable battery and supply and fixing new SMF battery having 30 Miniuts backup 12 Volt 42 AH SMF batteries with battery links complete all as specifed and directed . Make Exide/Amron

15

-

-

... More
Supply and fixing submain wiring with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing and caping of suitable dia, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing including taking down old unsv submain wiring complete all as specified and directed. Note :- (i) Two runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping

1600

-

-

... More
All as per item No 57.00 but 6 Sqmm sub main wiring complete all as specified and directed by Engr in Charge.

1500

-

-

... More
All as per item No 57.00 but 10 Sqmm sub main wiring complete all as specified and directed by Engr in Charge.

1200

-

-

... More
All as per item No 57.00 but 16 Sqmm sub main wiring complete all as specified and directed by Engr in Charge.

1000

-

-

... More
Supply and fixing in repair submain wiring 4 run x 10 sqmm + 1 run x 10 sqmm earh wire FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC casing and caping of suitable dia, ISI marked including 1 single core cable with stranded copper conductor of size 10 sqmm (green colour) for earthing. Note :- (i) Four runs of 10 Sqmm cable, 1 run of PVC casing & caping and 1 run of 10 Sqmm cable for earth shall be measured as 1 RM.

300

-

-

... More
Supply and fixing in repair submain wiring cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 3 core , 10 Sqmm and including laying , sadling with clamps, / laid in duct / along pole/wall alongwith suitable size of PVC conduict including making connection to DB complete all as specified and directed by Engineer-in-Charge.

500

-

-

... More
Supply & fixing in repair Plug and Socket enclosure, in sheet metal enclosure with MCB, DP 20 Amps 240 Volts complete with metal clad socket complete all as specifed and directed.

80

-

-

... More
Supply & fixing in repair DB 4 way Double door TPN type, 415 volt having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed.

25

-

-

... More
S & F in repair MCB TPN 40 to 100 Amps, 415 volt, 10 KA rating complete all as specified and directed.

100

-

-

... More
Taking down unserviceable light and Supply and fix Ceiling light 36 WATT (min 120 lumen /watt) 2 ft X 2 ft Recess mounting led ultra slimceiling light with extruded aluminium housing and milky diffuser LED ultra slim panel complete all as specified and directed.

90

-

-

... More
Supply of PVC DLP - On wall trunking with all finishing accessories (end, joint of lid, joint of body,interior angle, exterior angle, flat angle, derivation) confirming standard EN 50085-2-1.Trunking should accept Wiring device with all the functions by associating the accessory of installation.Trunking should confirm to the current specifications of NF C 68-104 in terms of both performance and level of functions provided by the system. Installation trunking (which carries electrical wiring accessories) should be type 3 (installation)in the new standard.Material should be Non-flame propagating. Degrees of protection provided by enclosure should be IP 40. Protection against mechanical impact should be IK 07. Trunking should be delivered in length of 2m. The trunking covers and partitions should be in PVC white RAL 9003.The accessories should be in plastic ABS white RAL as per details

-

-

-

... More
S & F in repair of PLASTIC TRUNKING 105mmX50mm with 2 Compartment with following acessories complete all as specified and directed by Engineer - in - Charge.

130

-

-

... More
(i) FLEXIBLE COVER 40MM WIDTH - 2 covers

260

-

-

... More
(ii) CLIP ON PARTITIONS

130

-

-

... More
(iii) BASE JOINT

65

-

-

... More
(iv) JOINT FOR 40MM WIDTH COVER

130

-

-

... More
(v) INTERNAL ANGLES-ADJ FRM 80 DEG

10

-

-

... More
(vi) EXTERNAL ANGLES-ADJ FRM 60 DEG

10

-

-

... More
(vii) FLAT ANGLES

10

-

-

... More
(viii) END CAP

10

-

-

... More
S & F in repair of PLASTIC TRUNKING 195mmX50mm with 2 Compartment with following acessories complete all as specified and directed by Engineer - in - Charge.

140

-

-

... More
(i) FLEXIBLE COVER 85MM WIDTH

280

-

-

... More
(ii) CLIP ON PARTITIONS

140

-

-

... More
(iii) BASE JOINT

70

-

-

... More
(iv) JOINT FOR 85MM WIDTH COVER

140

-

-

... More
(v) INTERNAL ANGLES-ADJ FRM 80 DEG

20

-

-

... More
(vi) EXTERNAL ANGLES-ADJ FRM 60 DEG

20

-

-

... More
(vii) FLAT ANGLE FOR 195X50-DLP TRU

20

-

-

... More
(viii) END CAPS

20

-

-

... More
Supply and fixing in repair sheet metal enclosure 12 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed by Engr in Charge.

30

-

-

... More
Supply and fixing in repair sheet metal enclosure 8 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed.

30

-

-

... More
Supply & fixing in repair MCB SPN (DP) 40 to 63 Amps, 240 Volts, 'C' curve, 10 KA complete all as specified and directed by Engr in Charge.

60

-

-

... More
Supply & fixing in repair MCB SP 6 to 32 Amps, 240 Volts, 'C' curve, 10 KA complete all as specified and directed by Engr in Charge.

960

-

-

... More
M & L for in repair maintenance free chemical earthing of environment friendly earth electrod set comprising of 17.2 mm dia , 3 m long rod low carbon steel molecular copper bounded for a thickness of 250 micro Omhs highly conductive ANS/INSF STD -60 certified carbon bound backfill compound which shall set like concrete accordingly to BS 7430 & IEEE 80 each bag shall contain 50 ibs alongwith pit cover complete ass as specified and directed.

20

-

-

... More
Material and labour for in repair PCC pit 1:2:4 type B-1, cover reinforced with XPM, weight not less than4kg/sqm and 6 mm dia bar handle earth pit angle iron frame of size 25x25x3mm complete all as specified and directed.

20

-

-

... More
Supply & fixing in replacement PVC non-metallic double locked casing ISI marked upto 25 mm with accessories fixed in wall/ceiling/truss including cutting chases as per site requirement complete all as specified and directed by Engr in Charge.

600

-

-

... More
Supply & fixing in replacement PVC conduict ISI marked upto 25 mm with accessories fixed in wall/ceiling/truss including cutting chases as per site requirement complete all as specified and directed by Engr in Charge.

400

-

-

... More
Supply and fixing in replacement single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 Sqmm in existing PVC casing caping/ new as per site requirement complete all as specified and directed by Engr in Charge.

800

-

-

... More
Supply and fixing in repair single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 2.5 Sqmm in existing PVC casing caping/ new as per site requirement complete all as specified and directed by Engr in Charge.

1400

-

-

... More
Refixing of existing PVC casing caping including copper wires with suitable size of screws and making the disturbed surface good complete all as specified and directed by Engineer in charge.

2000

-

-

... More
Supply and fixing hot water extension pipe made out of copper chromium plated 450 mm long with brass adaptor and fixing in position complete all as specified.

130

-

-

... More
Supply and fixing Cold water extension pipe made out of copper chromium plated 450 mm long with brass adaptor and fixing in position complete all as specified.

130

-

-

... More
M&L for stopping the leakage of the geyser of any capaciry by applying brazing to inner tank , or replace the nut bolts and refixing the inner tank after making it functional all as specified and as directed by engr-in-charge. Note : Adeuqate water pressure will be apply to the brazed tank to ensure that no leakage is left if the tank leaked the same will be repaired by the contractor witout claiming any additional cost from the department.

250

-

-

... More
Supply & fixing in replacement of heating element as required at site of 1.5 KW ISI marked as required at site and approved by Engr-in charge.

80

-

-

... More
Supply & fixing in replacement of heating element as required at site of 2.0 /03 KW ISI marked as required at site and approved by Engr-in charge.

90

-

-

... More
S& F in replacement geyser steel inner tank assembly suitable for geyser capacity of 03 Ltr complete all as specified and directed by engineer in charge.

30

-

-

... More
S& F in replacement geyser steel inner tank assembly suitable for geyser capacity of 06 Ltr complete all as specified and directed by engineer in charge.

30

-

-

... More
S& F in replacement geyser steel inner tank assembly suitable for geyser capacity of 25 Ltr complete all as specified and directed by engineer in charge.

35

-

-

... More
Supply & fixing in replacement of top plug 15 Amp 3 pin complete all as specified and directed by engineer in charge.

200

-

-

... More
Supply and fixing in repair Linear Aluminium Baten, inbuilt sensor based on smart LED auto dimmable from 100% of rated wattage to 30% on sensing of movement/occupancy, baten 20W Aluminium Extruded Chanel Powder Coated with opaque diffuser for glare free light complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified.

30

-

-

... More
Material and labour for attending emergency internal electrification complaints i.e shortcircuit, fault in internal wiring circuit, mcb triping, fault in DB, fault in meter panel, earth or current leakage in light circuit complete all as specified and directed by Engr in Charge. Note :- minor items i.e tape, thimble, etc included in the quoted rate.

350

-

-

... More
Supply and fixing in repair Mild Steel Galvanized Coating Powder Coated Cable Tray vantilatted channel type single compartment of size 300 mm x 50 mm x 2.0 mm for carrying of LT cable of suitable size fixing on wall/ angle iron along with all necessary fixing accessories ( bracket, nut bolts, washer, fastner) all as spcified and directed by Engineer-in-Charge.

200

-

-

... More
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in hard/dense soil for laying of cable/ GI pipe and getting out complete all as specified and directed.

380

-

-

... More
Returning, filling including spreading levelling watering well ramming in layers not exceeding 25cm complete all as specified and directed by Engr in Charge.

330

-

-

... More
Removing surplus soil to a distance outside MD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr in Charge.

50

-

-

... More
Supply, fixing, install, testing and commissioning of LT Panel ,indoor type ,three phase, 4 wire, aluminum bus bar rating 1200 amps for phases and 800 amps for neutral made out of CRCA sheet ,indoor type ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame of suitable size fixed in existing duct properly ,and of suitable size to accommodate the items mentioned below and having separate compartment /chambers for cable gallery busbar,switch gear and front side door openable , back side fixed wall etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc . INCOMING (a) ACB 4 Pole, 415 Volts, 800 Amps, 50 KA - 01 No. (for incoming) (b) ACB 4 Pole, 415 Volts 800 Amps, 50 KA - 01 No (for bus coupler) OUTGOING (a) MCCB 4 pole, 415 Volts, 315 Amps, 25 KA - 01 Nos with adjustable thermal and magantic release with Ics=100 Icu. (b) MCCB 4 pole, 415 Volts, 250 Amps, 25 KA - 03 Nos with adjustable thermal and magantic release with Ics=100 Icu. (c) MCCB 3 pole, 415 Volts, 200 Amps, 25 KA - 04 Nos with adjustable thermal and magantic release with Ics=100 Icu. (d) MCCB 3 pole, 415 Volts, 100 Amps, 25 KA - 01 Nos with adjustable thermal and magantic release with Ics=100 Icu. (e) MCCB 3 pole, 415 Volts, 63 Amps, 25 KA - 02 Nos with adjustable thermal and magantic release with Ics=100 Icu. (f) Multifunctional meter flush mounting type 96 x 96 mm - 02 Nos (g) Indicator lamp (RYB) (set of three) - 02 Set (h) CTs of suitable size.

1

-

-

... More
Supply, fix, install, testing and commissioning of LT Panel ,indoor type ,three phase, 4 wire, aluminum bus bar rating 1200 amps for phases and 800 amps for neutral made out of CRCA sheet ,indoor type ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame of suitable size fixed in existing duct properly ,and of suitable size to accommodate the items mentioned below and having separate compartment /chambers for cable gallery busbar,switch gear and front side door openable , back side fixed wall etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc . INCOMING (a) ACB 4 Pole, 415 Volts, 800 Amps, 50 KA - 01 No. (for incoming) OUTGOING (a) MCCB 4 pole, 415 Volts, 315 Amps, 25 KA - 01 Nos with adjustable thermal and magantic release with Ics=100 Icu. (b) MCCB 4 pole, 415 Volts, 250 Amps, 25 KA - 02 Nos with adjustable thermal and magantic release with Ics=100 Icu. (c) MCCB 3 pole, 415 Volts, 200 Amps, 25 KA - 05 Nos with adjustable thermal and magantic release with Ics=100 Icu. (d) MCCB 3 pole, 415 Volts, 100 Amps, 25 KA - 01 Nos with adjustable thermal and magantic release with Ics=100 Icu. (e) MCCB 3 pole, 415 Volts, 63 Amps, 25 KA - 02 Nos with adjustable thermal and magantic release with Ics=100 Icu. (f) Multifunctional meter flush mounting type 96 x 96 mm - 01 Nos (g) Indicator lamp (RYB) (set of three) - 01 Set

1

-

-

... More
Material & Labour for repairs/ Overhauling /Servicing to Existing LT electric panels Indoor type of each Transformer by taking shut down from appropiate authority including checking loose connections and tight connection and cleaning inside/out side all connection, replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors, providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as directd and specified. Note :- The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt Voltmeter/ Amp meter/CT/LED lamps of any type and discription etc , Note : Spare part wiil be measured and paid seprately as supply only vide relivant item No 97 to 111 of this schedule.

30

-

-

... More
(i) Cleaning inside the panel and all incoming and out going feeders i.e including MCCB/SFU/Changeover switches/Contactors/ ACB's thorouly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers (iii) Replacing the burnt out color coated PVC Sleeve of main and fedders bus bar with appropriated size of New PVC heat shrinkable sleeves -01Job

-

-

-

... More
(iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/Hrc Fuses.(Note: New items will be measured and paid separatly)-01Job (v) Replacing burnt out control wiring of Amp meter/Voltmeter/Indicating lamps and CT'swith 2.5/1.5Sqmm copper single core,1100V grade copper conductor cable- 01Job (vi) Replacing Burnt out Bus Bar of incomming and out going feeders with approprieted size of new bus bar (Copper/Aluminum) -01Job( Note : Bus Bar will measured and paid separately). (vi) Replacing Burnt out Insulators of incomming and out going feeders with approprieted size of new Insulators -01Job (vii) Spray Painting of Panel Board with one coat of synthetic enamel paint. (viii) Replacement of old burnt or rusted nut bolts as per existing size - 01 Job

-

-

-

... More
Supply only Digital LT voltmeter with selector switch of size 96x 96mm rating 0 to 500 volt all as specified and directed.

6

-

-

... More
Supply only Digital LT Ammeter with selector switch of size 96x 96mm suitable for CT ratio 5amp, progaramable type complete all as specified and directed.

12

-

-

... More
Supply only indicating lamp holder with bulb LED(Red Yellow,Blue,Green) type to indicate incoming supply suitable for 24 V DC/110 VAC/230Volts AC and all as specified and directed.

60

-

-

... More
Supply only Aluminium Bus Bar strips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed.

20

-

-

... More
Supply only Copper Bus Bar strips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed.

20

-

-

... More
Note for item No.120 &121 (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account. (d) Rate of Bolts, Nuts etc shall be included in quoted rate.

-

-

-

... More
Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1250Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete and unserviceable item will be paid seprately as supply only under item No 103 to 112 of this schedule.

10

-

-

... More
Supply only Spring Charging Handle suitable for upto 1250A ACB complete all as specified and directed.

2

-

-

... More
Supply only CT's suitable for air circuit breakers of rating 630Amps complete all as specified and directed.

2

-

-

... More
Supply only CT's suitable for air circuit breakers of rating 800Amps complete all as specified and directed.

2

-

-

... More
Supply only CT's suitable for air circuit breakers of rating 1250 Amps complete all as specified and directed.

2

-

-

... More
Supply only Auxiliary contact block suitable for air circuit breakers of rating 630Amps to 1250 Amps complete all as specified and directed.

4

-

-

... More
Supply only arcing (fixed/moving) suitable for air circuit breakers of rating 630 Amps to 1250Amps complete all as specified and directed.

5

-

-

... More
Supply only arc chutes (for 415V) suitable for air circuit breakers of rating 630Amps to 1250Amps complete all as specified and directed.

4

-

-

... More
Supply only shunt release(110/220V DC or 240V/415V AC) suitable for air circuit breakers of rating 630Amps to 1250Amps complete all as specified and directed.

3

-

-

... More
Supply only cluster contact suitable for air circuit breakers of rating 630Amps to 1250Amps complete all as specified and directed.

3

-

-

... More
Supply only trip coil suitable for air circuit breakers of rating 630Amps to 1250Amps complete all as specified and directed.

2

-

-

... More
Material and labour for repairing of Capacitor (APFC ) panel of 100KVAR to 400KVAR and carryout repairs as (i)Dismantling of Power contactor,TP,415Volts and auxiulary contactors and cleaning,Overhauling, servicing, repairing thoroughly and replacing burnt contactors upto 63Amps including suitable capacity of copper wire single core,1100Volts grade -01 Job.

4

-

-

... More
(ii)Replacing of the HRC fuses and fuse base with MCB, D'curve,TP,415Volts upto 63Amps with mounting rail including suitable capacity of copper wire single core,1100Volts grade. (New MCB will be measured paid separately) (iii)Dismantling ,testing and replacing of damaged Capacitor banks up to 25KVAR including suitable capacity of copper wire single core,1100Volts grade (New Capacitor banks will be measured paid separatly) (iv) Reapair/repalcement of controle wiring of realy,contactors,aux contactors,indicating circuits,auto/manual circuits etc including all logic circuit with new copper wire single core1.5/2.5Sqmm,1100Volts grade-01Job (v)Testing and repairing / replacing of timer-01Nos & auxillary contractor (vi) Testing and replacing of A/M selector switch-01No.,Ammeter-01no ,Voltmeter-01No,selector switches with CT's -01Set. (vii) Testing and repair/replacing of controle fuses with base capacity up to 20 Amps (viii) Relacing of power wiring from bus bar to fuses and fuse to contactors and contactors to capacitor banks of size single core,flxible copper conductor, 4Sqmm to 16Sqmm cable with Copper lugs. (ix) Testing and Repairing/Replacing APFC relay 8 to 12 stage, digital type.(New Relay will be measured paid separatly) (x)Testing and repairing / replacing of Indicating lamps LED type-24Nos and push bottons. (xi)Checking and testing of all logical fuctions and commissioning the panel board. Note :- New parts wiil be measured and paid seprately as supply only under item no 114 to 130 of this schedule.

-

-

-

... More
Supply only Capacitor bank 5KVAR, Heavy duty type,415Volts,50Hz AC supply in existing panel complete all as specified and directed.

8

-

-

... More
Ditto all as per item No.136.00 but of rating 10KVAR

4

-

-

... More
Ditto all as per item No. 136.00 but of rating 15KVAR

3

-

-

... More
Ditto all as per item No. 136.00 but of rating 20KVAR

3

-

-

... More
Ditto all as per item No.136.00 but of rating 25KVAR

3

-

-

... More
Supply only Power contactors Capacitor Duty(Type MOC of L&T) 50Amps Capacitor duty with 2NO+2NC suitable for 415Volts,50Hz AC supply in existing panel complete all as specified and directed.

2

-

-

... More
Ditto all as per item No.141.00 but rating 40Amps

2

-

-

... More
Ditto all as per item No.141.00 but rating 32Amps

4

-

-

... More
Supply & fixing MCB,TP,C'Curve,63 Amps,415Volts,50Hz AC supply in existing panel with mounting rail complete all as specified and directed by Engr-in-charge.

3

-

-

... More
Ditto all as per item No.144.00 but rating 40Amps

2

-

-

... More
Ditto all as per item No.144.00 but rating 32Amps

3

-

-

... More
Ditto all as per item No.144.00 but rating 20Amps

4

-

-

... More
Supply only Auxilaury contactors 10Amps Capacitor duty with 8NO+8NC suitable for ,415Volts,50Hz AC supply in existing panel complete all as specified and directed.

2

-

-

... More
Supply only Time relay Timer suitable for APFC panel ,415Volts,50Hz AC supply in existing panel complete all as specified and directed.

4

-

-

... More
Supply only Current Transformers, 415V 600/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel complete all as specified and directed.

4

-

-

... More
Supply only Current Transformers, 415V 400/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel complete all as specified and directed.

1

-

-

... More
Supply only Current Transformers, 415V 200/5Amps,15VA burden,accuracy class 1 for metering accuracy for in existing panel complete all as specified and directed.

3

-

-

... More
Material and Labour for Attending Faults/Trippings and rectifing /repairing the faults in LT Panels Boards/Capacitor Panels Boads/ MCCB's/ACB's /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. Note : Note : (i) Spare parts will be measured and paid separately (ii) Fault rectfication and restore the supply withing 4hrs otherwise penality liable Rs 500 per our till supply will restore.

50

-

-

... More
Material and labour for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage complete all as specified and directed by Engineer-in-charge.

15

-

-

... More
Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable) and accessories suitable for 3.5 core XLPE armoured, aluminum conductor cable of size 16 to 35 sq mm and all as directed by Engineer-In-Charge.

12

-

-

... More
Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, aluminum conductor cable of size 50 to 70 sq mm and all as directed by Engineer-In-Charge.

14

-

-

... More
Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, aluminum conductor cable of size 70 to 95 sq mm and all as directed by Engineer-In-Charge.

10

-

-

... More
Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, aluminum conductor cable of size 120 to 185 sq mm and all as directed by Engineer-In-Charge.

12

-

-

... More
Supply and fixing cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, aluminum conductor cable of size 240 to 300 sq mm and all as directed by Engineer-In-Charge.

7

-

-

... More
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 300Sqmm 3.5 core including taking down old faulty cable complete all as directed by Engineer-In-Charge.

50

-

-

... More
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 185Sqmm 3.5 core including taking down old faulty cable complete all as directed by Engineer-In-Charge.

150

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 150Sqmm 3.5 core including taking down old faulty cable complete all as directed by Engineer-In-Charge.

160

-

-

... More
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core including taking down old faulty cable complete all as directed by Engineer-In-Charge.

200

-

-

... More
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core including taking down old faulty cable complete all as directed by Engineer-In-Charge.

130

-

-

... More
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core including taking down old faulty cable complete all as directed by Engineer-In-Charge.

100

-

-

... More
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core including taking down old faulty cable complete all as directed by Engineer-In-Charge.

200

-

-

... More
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core including taking down old faulty cable complete all as directed by Engineer-In-Charge.

200

-

-

... More
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core including taking down old faulty cable complete all as directed by Engineer-In-Charge.

400

-

-

... More
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core including taking down old faulty cable complete all as directed by Engineer-In-Charge.

200

-

-

... More
Cutting metal road/hard standing for laying of cable and re mataling/making good the same to match the existing surface complete all as directed by Engr incharge.

25

-

-

... More
Supply & fixing in repair GI tubing light grade 100 mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc.

25

-

-

... More
Supply & fixing in repair GI tubing light grade 50 mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc.

20

-

-

... More
M&L for High density poly-ethylene pipes (HDPE) of pressure PN 6(0.6 Mpa), material grade PE 63, 90 mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.Make: Supreme/Kisan/Finolex/Astrol/Prince

450

-

-

... More
M&L for High density poly-ethylene pipes (HDPE) of pressure PN 6(0.6 Mpa), material grade PE 63, 63 mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed. Make: Supreme/Kisan/Finolex/Astrol/Prince

500

-

-

... More
M&L for High density poly-ethylene pipes (HDPE) of pressure PN 6(0.6 Mpa), material grade PE 63, 40 mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed. Make: Supreme/Kisan/Finolex/Astrol/Prince

650

-

-

... More
Supply & fixing electrical Insulating mat confirming to IS15652/2006 class B, minimum thickness 2.5 mm , maximum leakage current 10mA, low temperature, flame retardance using at power houses including pasting of rubber mats with adhesive resin all as specified and directed by Engineer-in-Charge.

150

-

-

... More
M&L for iron Chequered plate as per site requirement including cutting to required shape and appling two coat of synthetic enamel paint over a coat of red oxide and all as directed

800

-

-

... More
Material and labour for Angle Iron work size as per requirement of site applying two coats of synthetic enamel paint over a coat of red oxide primer and all as directed by Engr in Charge.

100

-

-

... More
Material and Labour for Attending Faults/Trippings and rectifieng /repairing the faults in DG Sets/AMF Panels etc including PVC insulating Tapes/Nut bolts and all as specified and directed by Engineer-In-Charge. Note : Note : (i) Spare parts will be measured and paid separately (ii) Fault rectfication and restore the supply withing 4hrs otherwise penality liable Rs 500 per our till suupply will restore.

20

-

-

... More
Supply & fixing in replacement of battery 12 volts 180 AH suitable for DG set starting complete all as specified and testing and commisioning complete all as specified and directed by Engineer In Charge.

2

-

-

... More
Supply & fixing in replacement of battery 12 volts 150 AH suitable for DG set starting complete all as specified and testing and commisioning complete all as specified and directed by Engineer In Charge.

1

-

-

... More
Material & Labour for Repairing/Servicing of AMF panel of capacity 25KVA to 125KVA as under complete all as specified and directed by Engineer-in-Charge. :-

5

-

-

... More
(i) Checking of auto/manual functions and other logical functions of AMF panel including battery charging system,Lub oil pressure sytem,Engine start ,stop,over load etc..

-

-

-

... More
ii) Repair/replacing of control wiring 1.5/2.5Sqmm copper cable

-

-

-

... More
iii) Repair/replacing of Engine start relay 24Volt DC/ AMF relay

-

-

-

... More
iv) Repair/replacing of PLA relay 3 C/O,240Volt AC/AMF relay

-

-

-

... More
v) Replacement of Sequency relay/AMF Relay

-

-

-

... More
vi) Repair/replacing of Timer

-

-

-

... More
vii) Repair/replacing indicating lamps

-

-

-

... More
viii) Repair/replacing of Auto/Manual selector switch

-

-

-

... More
ix) Repair/replacing of Auxualary contactros

-

-

-

... More
x )Repair/replacing of main power contactros

-

-

-

... More
xi) Repairing/replacing of Under Voltage relay

-

-

-

... More
xii)Testing of the panel at site with functions of DG sets

-

-

-

... More
Note : Spares will be measured and paid separatly as supply only under item no 161 to 173 of this schedule.

-

-

-

... More
Supply only Power Contactor,50A,4pole with 2NO + 2NC suitable for 25KVA DG set existing AMF Panel and complete all as specified and directed by Engineer In Charge.

2

-

-

... More
Supply only Power Contactor,80Amps ,4pole with 2NO+2NC suitable for 62.5KVA DG set existing AMF Panel and complete all as specified and directed by Engineer In Charge.

1

-

-

... More
Supply only Power Contactor,100Amps ,4pole with 2NO+2NC suitable for 82.5KVA DG set existing AMF Panel and complete all as specified and directed by Engineer In Charge.

1

-

-

... More
Supply only Power Contactor,130Amps ,4pole with 2NO+2NC suitable for 100/110KVA set existing AMF Panel and complete all as specified and directed by Engineer In Charge.

2

-

-

... More
Supply only Power Contactor,160Amps ,4pole with 2NO+2NC suitable for 125KVA set existing AMF Panel and complete all as specified and directed by Engineer In Charge.

3

-

-

... More
Supply only of ON relay timer in existing AMF Panel and complete all as specified and directed by Engineer In Charge.

4

-

-

... More
Supply only of AMF relay suitable for 25KVA to 62.5KVA in existing AMF Panel and complete all as specified and directed by Engineer In Charge.

2

-

-

... More
Supply only of AMF relay suitable for 82.5KVA to 125KVA in existing AMF Panel and complete all as specified and directed by Engineer In Charge.

3

-

-

... More
Supply only Auxiluary Contactactor, with 4NO+4NC in existing AMF Panel and complete all as specified and directed by Engineer In Charge

4

-

-

... More
Supply only PLA relay 3 C/O,240Volt AC, with socket in existing AMF Panel and complete all as specified and directed by Engineer In Charge

1

-

-

... More
Supply only Under Voltage relay in existing AMF Panel and complete all as specified and directed by Engineer In Charge.

2

-

-

... More
Supply only Under Voltage relay LED indicating lamps(Red/Green/Yellow/Blue) 24/230V AC /DC in existing AMF Panel and complete all as specified and directed by Engineer In Charge.

14

-

-

... More
Supply only A/M selector switch in existing AMF Panel and complete all as specified and directed by Engineer In Charge.

4

-

-

... More
Taking down old unserviceable ACB any type and Supply, installation testing and commissioning new LT ACB of 800 Amps four pole mannual draw out microprocessor based, 415 Volts, 50 Hz suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar /nut bolts/lugs complete all as specified and directed by Engr-in-charge.

1

-

-

... More
Supply and fixing in repair MCCB four pole 400 amps 415 volt , 50 Hz breaking capacity not less than 36 KA complete all specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fixing in repair MCCB four pole 320 amps 415 volt , 50 Hz breaking capacity not less than 36 KA complete all specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fixing repair MCCB four pole 250 amps 415 volt , 50 Hz breaking capacity not less than 36 KA complete all specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing in repair MCCB four pole 160 amps 415 volt , 50 Hz breaking capacity not less than 36 KA complete all specified and directed by Engr-in-Charge.

4

-

-

... More
Supply and fixing in repair MCCB four pole 100 amps 415 volt , 50 Hz breaking capacity not less than25 KA complete all specified and directed by Engr-in-Charge.

4

-

-

... More
Supply and fixing in repair MCCB four pole 63 amps 415 volt , 50 Hz breaking capacity not less than25 KA complete all specified and directed by Engr-in-Charge.

2

-

-

... More
Supply & fixing in replacement change over switch ON LOAD type, 415 volt, 50 Hz, AC 4 pole in sheet steel enclosures, capacity 400 Amps rated current manually operated confirming to IS : 13947 or lates edition with hight thermal and dynamic strength to with stand short circuit current level of 80 KA rms complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply & fixing in replacement change over switch ON LOAD type, 415 volt, 50 Hz, AC 4 pole in sheet steel enclosures, capacity 315 Amps rated current manually operated confirming to IS : 13947 or lates edition with hight thermal and dynamic strength to with stand short circuit current level of 80 KA rms complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fixing in repair MCCB 3 pole 630 amps 415 volt , 50 Hz breaking capacity not less than 36 KA complete all specified and directed by Engr-in-Charge.

1

-

-

... More
Supply, fixing, install, testing and commissioning of LT Panel ,indoor type cubical shape,three phase, 4 wire, copper bus bar rating 400 amps for phases and 200 amps for neutral made out of CRCA sheet ,2 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,1 ft long grouted on PCC foundation of height not less than 40 cm from the ground level , grouting properly ,and of suitable size to accommodate the items mentioned below and having separate compartment /chambers for cable gallery busbar,switch gear and front side door openable , back side fixed wall etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc . (i) MCCB 4 Pole, 415V, adjustable type, 250 Amps with breaking capacity 25KA -01 No (Incoming) (ii) MCCB 4 pole 415V fixed type, 25 to 160 Amps with breaking capacity 16KA- 03 Nos (outgoing) (iii) Motor star delta starter suitable for UPTO 40 HP motor - 02 Nos (iv) Voltmeter/ Ammeter,digital type 0- 400 volt,with selector switch -03 set (v) Phase indicating lamps LED type ( red , yellow, blue) -03 set (vi) MCB SPN 40 Amps- 06 Nos (outgoing)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.