Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Solar Installation and Products
Water Storage And Supply
Electrical Works
Eprocure
Opening Date14 Feb 2024
Closing Date5 Mar 2024
Tender Amount₹ 37,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in soil including spreading in low lying area and leveling complete all as specified and as directed.

5

-

-

... More
Cutting the existing road/hard standing/chequered cement concrete tiling/PCC floor etc,. not exceeding 50cm wide, and refilling with excavated material after laying CI/GI pipe line all as specified and as directed.

0.8

-

-

... More
Supply, Laying, fixing in repair steel water tubing, medium grade, galvanised, with screwed and socketed joints, in any length, including supply and fixing all fittings, fixed to walls or laid in trenches / floors etc complete all as specified and as directed for the 20 mm bore and taking down old unserviceable pipes complete.

15

-

-

... More
All as per item No 6 above but 25mm bore .

30

-

-

... More
All as per item No 6 above but 40mm bore

30

-

-

... More
All as per item No 6 above but 50mm bore

30

-

-

... More
All as per item No 6 above but 80mm bore

50

-

-

... More
All as per item No 6 above but 100mm bore

30

-

-

... More
Supply and fix for Hose Reel Drum, with high pressure fire hose reel of 30m in length, conforming to IS marked, complete all as specified and as directed.

1

-

-

... More
Supply and fix for jet spray shut-off polymer nozzle for hose reels conforming to EN 671-1, leak proof, corrosion free, rotary operated, Super tough recyclable polymer alloy used with red in colour complete all as specified and as directed. Make :- Best available in market

2

-

-

... More
Supply and fix for Shut-off nozzle 20 mm in size Non ferrous/Gun metal with leak proof, corrosion free complete all as specified and as directed. Make :- Best available in market

2

-

-

... More
Supply and fix in repairs ISI Marked UPVC Pipe size 50mm nominal dia,pressure pipe schedule 80 with all connected acessories like UPVC bend,Tees,Unions,Sockets etc for each 3 mtr length of Pipe & solvent to join it including taking down old unserviceable pipes complete all as specified and as directed. Make:Supreme/Dutron/Finolex/Duplon

50

-

-

... More
All as per item No.15 above but of 40mm dia

50

-

-

... More
All as per item No.15 above but of 25 mm dia

50

-

-

... More
Supply only Calcium hypo chlorite 65% -70% chlorine content granular based water disinfectent in sealed containers complete all as specified and as directed. Make:- 1.Aqufit manufactured by Sree Rayalaseema Hi strength Hypo Ltd. 2. Puri chlor manufactured by Sree Rayalaseema Hi strength Hypo Ltd. / M/s Ravi Enterprises / M/s Potter & Watts (Traditional products). Brands having pan india availability, acceptability & being manufactured /processed in open market termed as traditional products .The brands /makes must have certified by All India Institute of Hygenic & Public Health. 3. Best available in the market

250

-

-

... More
S&F in repairs gunmetal gate or globe valve for 50mm dia, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing,a including taking down old unserviceable gate or globe valve complete all as specified and as directed

4

-

-

... More
All as per item No 19 above but 40mm dia

4

-

-

... More
All as per item No 19 above but 25mm dia

4

-

-

... More
All as per item No 19 above but 20mm dia

4

-

-

... More
S&F for fabricate supply and fix MS flat clamps made out MSFI of size 40 x 6 mm (confirming to Fe 290 Gde-165 ) including drilling hole, nut, bolts, washer and made to shape of required size ie. for 200 mm dia / 150 mm dia / 100 mm dia MS pipe.

50

-

-

... More
Taking out in repairs sluice valves of size 80mm to 100mm and refacing, regrinding and refixing to match with standard size and refixing in position including replacing of defective gland packing/washer /nuts/ set screws etc for 80mm to 100mm size sluice valves. Note : Rate quoted is inclusive of cost of spare parts.

2

-

-

... More
All as per item No 24 above but for size 150mm to 200mm dia

2

-

-

... More
S&F in repairs sluice valve 100mm bore, cast iron body, flanged and drilled end, conforming to IS-14846, ISI marked, class PN 1.6 including all joints with rubber or fibre board, gaskets, bolts and nuts, washers, iron wheel including taking up / down old unserviceable valves from any position and any addition / alteration for fixing required complete all as specified and as directed

1

-

-

... More
All as per item No 26 above but 150mm bore

1

-

-

... More
All as per item No 26 above but 80mm bore

1

-

-

... More
M&L in repairs for run lead joints to CI spigot and socket pipes of 80mm bore and fittings including cleaning the joints, re-aligning the pipeline properly as required, cocking and jointing with old pig lead, including any addition / alteration for fixing required, testing pipelines for any leakage , making good any disturbed / damaged pipeline / parts etc, complete all as specified and as directed Note ; Necessary excavation and earthwork will be measured and paid separately

2

-

-

... More
All as per item No 29 above but 100mm bore

2

-

-

... More
All as per item No 29 above but 150mm bore

2

-

-

... More
S&L in repairs cast iron pipes of 80mm bore with spigot and socket ends centrifugally cast, Class LA, confirming to IS suitable for lead joints in any length laid in trenches including taking out old damaged CI main including fitting burning out joints and recovering lead complete etc as specified and directed.

10

-

-

... More
All as per item No 32 above but 100mm bore

10

-

-

... More
All as per item No 32 above but 150mm bore

10

-

-

... More
All as per item No 32 above but 200mm bore

10

-

-

... More
M&L in repairs for CI fittings confirming to IS for spigot and socket pipes, upto 150mm bore such as bends, tapers, tee pieces single branch, collars etc.

50

-

-

... More
All as per item No 36 above but 200 to 300mm bore.

50

-

-

... More
Supply and fix in repairs display boards of size 4 feet x 3 feet showing machine details/specifications of pumpsets/filteration plants and for ozonator including taking out old u/s display boards complete all as specified and as directed by Engr-in-charge.

2

-

-

... More
Fabricate supply and fix in repairs valve chamber covers made out of suitable size MS angle/MS plate/flat/rod, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removing existing unserviceable rusted cover all as directed.

50

-

-

... More
Supply and fix in repairs 50mm bore PVC Ball valve ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed including taking out old u/s PVC ball float valve complete all as specified and as directed by Engr-in-charge.

10

-

-

... More
All as per item No.40 above but 40mm bore

10

-

-

... More
All as per item No.40 above but 25mm bore

10

-

-

... More
All as per item No.40 above but 20mm bore

10

-

-

... More
Supply and fix schematic diagram of swimming pool plant display board of size 1000mm x1000mm including all pipe lines,pumpsets,and other equipments all in detail in different colour code all as directed by Engr-in-charge.

1

-

-

... More
Supply and fix in repairs cast iron water meter of size 50mm class B flange type conforming to IS-2373 including taking down old u/s water meter complete all as specified and as directed Make:Kranti/Capston/Dashmesh/Accuflow or equivalent.

1

-

-

... More
Supply and fix in repairs cast iron water meter of size 80mm class B flange type conforming to IS-2373 including taking down old u/s water meter complete all as specified and as directed Make:Kranti/Capston/Dashmesh/Accuflow or equivalent.

1

-

-

... More
Supply and fix in repairs cast iron water meter of size 150mm class B flange type conforming to IS-2373 including taking down old u/s water meter complete all as specified and as directed

1

-

-

... More
M&L in repairs for petty repair work by replacement of fittings such as elbow,socket,tee etc and depositing the complaint slip in complaint cell after user signature complete as per directed by engineer in charge.

6

-

-

... More
M&L in repairs for angle iron, U shape channel of any size as per site requirement, welding to required shape, including all nuts,bolts,washers etc complete all as specified and directed by engineer-in-charge.

60

-

-

... More
M&L for PCC foundation 1:2:4 as per site requirement,including form work complete all as specified and directed by engineer-in-charge.

2

-

-

... More
Supply only OT solution for chlorine test(500ml),complete all as specified and directed.

4

-

-

... More
Supply only phenol red solution for PH test(500ml),complete all as specified and directed.

4

-

-

... More
Supplying, fixing, jointing and testing, in repairs ISI marked heavy grade, Class C, MS ERW pipe of 100 mm conforming to IS: 1239-1982, including fittings such as coupling, bends, elbow and tee screwed/flanged joints, nuts & bolts, rubber packing rings,fixed on wall, hanged with ceiling through clamps, hangers, brackets, pipe supports, U bolts on MS brackets with anchor fasteners all as directed and appliying 2 coats of synthetic enamel paint over a coat of zinc dichromate primer, etc as per the site requirement in long/short pieces including taking down old MS ERW pipes complete all as specified and directed by Engr-in-charge. Make :- Tata/ Jindal / BST/ Oswal

30

-

-

... More
All as per item No 53 above but 80mm bore

30

-

-

... More
All as per item No 53 above but 150mm bore

22

-

-

... More
Supply and fix in repairs flanged yard hydrant/Stand post of 80 mm dia MS with double end flanged type 1.5 m height including taking down old u/s hydrant/stand post complete all specified and as directed by Engr- in - Charge. Make :- Best available in the market

3

-

-

... More
Supply and fix in repairs 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903 including taking down old u/s hose complete all specified and as directed by Engr- in - Charge. Make:- NewAge / Essel / Swati

3

-

-

... More
Supply and fixing in repairs fire hose cabinet box of size as per requirement but not less than 800X600X250 mm, out door type Made out from 16 Gauge MS sheet duly painted with 2 coats of red colour synthetic enamel paint over a coat of redoxide primer with double leafed glazed shutters (Glaged with 4mm thick glass) suitable for housing of 2 length of canvas hose, branch pipe, fire hose nozzle, fire man axe, first aid hose and single outlet landing valve,including free standing stand made of of MS angle of size 40 mm X 40mm X 5 mm and including pcc foundation of required size but not less than 0.45 mtr height above ground level including dismantling old cabinet hose box complete all as directed. Make :- Vijay / Winco / Ceasefire

5

-

-

... More
Supply and fixing, in repairs Gun Metal, single outlet type fire hydrant landing valve, type A ISI marked of size 63mm dia complete with brass spindle cast iron wheel, with rubber gasket, nut,bolt etcand instantaneous coupling ISI marked, confirming to IS 5290 hydrostatic test pressure 23 kg/cm2, minimum operating pressure 7kg/cm2 including taking down old u/s fire hydrant landing valve complete all as directed. Make:- NewAge / Essel / Swati

2

-

-

... More
Supply and fix in repairs Pressure gauge of 4" dial 0-14 kgs rating with ball valve including taking up / down old unserviceable pressure gauge from any position and any addition / alteration for fixing required including taking down old u/s pressure gauge complete all as specified and as directed.

5

-

-

... More
Fabricate supply and fix in repairs valve chamber covers made out of suitable size MS angle/MS plate/flat/rod,hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removing existing unserviceable rusted cover all as directed.

90

-

-

... More
M & L for earthing chemical with copper plated 50 mm dia pipe 3 mtr long (100 microns) including Electrodite 50 Kg buried directly in ground including earth bore hole work (earth bore not less than 3 Mtr deep below normal ground level and connected to copper earth strip of size 20×3 mm by means of copper nuts bolts with washers and connected as per following specifications complete all as directed by Engineer-in-Charge. (a) Product Model: ASEEL 19 CP, 3 meter long (Copper Plated) – 100 microns . Fast Electrode, Model FE 80 mm 3 mtr (Pure Copper Single Pipe), Outer Dia is 80 mm with a wall thickness of 2 mm, Inner Dia is 26 mm with a wall thickness of 2.6 mm, Overall Length is 3000 mm, External Corrosion Protection: Copper Plated (100+ microns), Internal Corrosion Protection: In addition to Copper Plated (100+ microns), a ground breaking corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance. Conforms to IS: 3043 - 1987 i.e., Code Of Practice For Earthing (+ 10%) variations in dimensions applicable. (b) Electrodite backfill: Fast Electrode Earth Enhancement Compound, Manufactured using Eco - Friendly minerals, Blended homogeneously with conductive carbon(s), Resistivity: 5 ohm-metre (In ideal moist conditions); 5 ohm-metre (Dry Conditions), Ph Value: 7.0 - 8.5, High water retention capacity, Hygroscopic, Ionic & Electronic conduction, Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil which is a crucial aspect in the performance of an earthing system. Packing Size : 2 Bags of 25 kilograms, Recommended for normal soil conditions. Conforms to IS : 3043 – 1987. (c) Installation of earthing with bore well machine complete for bore exceeding upto 4.5 meter below ground level complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
S&F in repairs 20x3mm copper strip all as directed including welding brazing and taking down of old copper strips as required at site

32

-

-

... More
M & L for preparation of old painted / unpainted surfaces of any description, including taking out of parts / components under painting from any position / location as listed under GE (NW) Mankhurd and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-In-Charge for the following capacity of electric motor. (a) Electric motor pump set upto 167 HP capacity

2

-

-

... More
(b) Electric motor pump set upto 150 HP capacity

2

-

-

... More
(c) Electric motor pump set upto 20 HP capacity

2

-

-

... More
(d) Electric motor pump set upto 7.5 HP capacity

2

-

-

... More
M & L for preparation of old painted / unpainted surfaces of any description, including taking out of parts / components under painting from any position / location as listed under GE (NW) Mankhurd and applying one coat of synthetic enamel paint over a coat of red oxide primer for Low Tension (LT) indoor type panel with new danger sign board made from mild steel, thickness not less than 1.6mm and size of 200 x 150 mm, vitreous enamelled white, with letters, figures and the conventional skull and cross bones in signal red colour on the front side and rear side of the plate also be enamelled conforming to IS- 2251-1982, complete all as specified and as directed by Engineer-In-Charge. Make: Asian paints / Berger / Nerolac

5

-

-

... More
Comprehensive maintenance & GPRS charges for LPRF energy metering system installed at NOFRA, NSB under GE (NW) Mankhurd including all supporting units/system & software’s for the period of one year (on all days including holidays) comprising of following all as specified & directed by Engineer in Charge. i)   The entire system shall be inspected and checked by the service engineer atleast once in one month of OEM (Main manufacturer) and replacement of spares and updating/reinstalling of software including testing etc records of the same is to be submitted to department. ii)   In case of fault as errors noticed in the system the defects should be rectified immediately with in 24 Hrs iii) Checking serviceability of all Meters, Data Concentrator Unit (DCU), Repeater unit, Software, Computer & Printers. (iv) Unit per month Means - Calendar month irrespective of days i.e 28 days to 31 days.

12

-

-

... More
Material and labour for preparing old painted steel pipe surface such as Rising pipe (Red), Delivery pipe (Blue), Overflow washout pipe (Yellow) , fire hydrant stand post and any exposed pipe etc and applying one coat of synthetic enamel paint for any bore GI pipe complete all as specified and as directed. Make: Asian paints / Berger / Nerolac

200

-

-

... More
Supply and fixing in repairs water level indicator, 36" dia as per IS and including numbering with radium stickering heavy duty float, counter weight heavy duty driving gear nylon wire fitted in all in GI housing, cutting the RCC slab and making good the slab, painting the exposed surface with two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed. Make: Flowtech / Nishka / Best available in the market

2

-

-

... More
S & F in repairs of motorised rolling shutter of capacity 400 K.g. of size 5000 mm (W) X 6000 mm (H) along with curtain made of single skinned galvalume steel laths with natural finish, pressed galvalume steel hood & motor cover with natural finish, CE certified CRS compact, gear P.R.C three station push button with deadman control, windlock storm anchor external safety brake complete as all specified and directed by the engineerg-in charge . The motorised rolling shutter shall confirm to the following technical specification: (i) Surface: Galvalume with natural finish (ii)Material thikness: 1.0 mm (iii) Curtein weight: 13 kg/m² approx (iv) Structure shape: Curved (v) Support Bracket mild steel wiih one coat of aluminium paint over coal of grey primer by spray. (vi) Shaft: Shaft is manufactured from mild steel tube of suitable outside diameter and wall thickness to suit the shutter application and is unsprung (vii) Finish : One coat of aluminium paint over a coat of Grev epoxy primer spray (viii) Side Guides: 5.0 mm thick heavy duty mild stee! storm guide (ix) Bottom Profile: Bend resistance double skinned extruded aluminium profiie forl additional strength. The bottom rail is filtted with exlruded rubber bottom, seal that will seal against the floor when the door is fully closed (x) Hood A Motor Cover. Pressed galvalune steel hood box complete with reinforced bracket as requried to suit the shutter width (xi) Drive Unit: Indirect drive operation (xii) Safety mechanism: Safety brake in accordance with EN- 14124-1: 2007 safety of machinary. (xiii)Contro! Swiich: Three station push button with deadman control (xiv) Emergency manual operation: Emergency operation by means of chain operation.

2

-

-

... More
All as per Item No. 72 here in before but Capacity of 600 K.g

4

-

-

... More
All as per Item No. 72 here in before but Capacity of 800 K.g

6

-

-

... More
All as per Item No. 72 here in before but Capacity of 1000 K.g

2

-

-

... More
All as per Item No. 72 here in before but Capacity of 1500 K.g

1

-

-

... More
Comprehensive maintenance of Chemical Type Dehumidification Plant of capacity 900 CFM (1500CMH) to maintain condition of 40% x 5 RH complete including all equipments, accessories of make Bry Air model FFB-1500 total 12 No's unit complete installed at New CMT Complex Mankhurd comprising of the following:- (i) Dehumidfier totally self contained unit CNC fabricated unit with powder coated finish, rotary type working on the principle of chemical adsorption to remove moisture from air on a continuous basis by use of desiccant synthesized fluted type media in rotor form and is Indigenous made. (ii) Desiccant honey comb rotor media adsorbent non-toxic,non-flammable,water washable. (iii) Desiccant rotor bed horizontal type. (iv) Casing advanced component welding. (v) Dehumidifier to having capacity by oversized by 60% of the normal capacity without deterioration in performance and pressure drop. (vi) Suitable for continuous operation. (vii) Auto/Manual selector switch (vii) Power on,heater on/off with fault status indication. (viii) Volume control,damper for both (reactivation & process) air flow. (ix) Humidity Control by digitally controlled humidistat on/off. (x) High temperature safety thermostat,cutout,react Cool safety device. Scope of work as follows:- Servicing: 01. Checking the motors and starter / contactors. 02. Checking the operation and proper functioning of controls. 03. Checking up bed speed and bed drive. 04. Inspecting and cleaning the air filters. 05. Lubricating the bearings of motors, fans etc. 06. Inspection of “Reactivation” side “Regeneration Heat Source” 07. Inspection Of seals. 08. Inspection of draft gauge. 09. Checking the inlet & outlet dampers. 10. Inspection of Actuator unit. 11. Inspection of flexible connection of “Process” & “Reactivation” fans from unit. 12. Inspection of V-belt and adjustment of tension. 13. Checking the air pressure balancing and air flow of the system / unit. 14. Checking the plant performance. 15. Checking of all other charts furnished with the unit and their appropriate functioning as per system design. Overhauling : Once A Year ( During Quarterly Visits) In addition to the ‘servicing’ mentioned above, the supervision of overhauling activity wil include the followings : 1. Checking and inspection of bed(s), bed screen. 2. Checking and inspection of bed seal, centre divider seal and radius and end seal for 3. Greasing / lubricating of all motors, drives, bearings etc. 4. Checking and inspecting impellers of “Reactivation” fans as well as “Process” fan. 5. Cleaning and overhauling of draft gauge. 6. Change of V-belts, if necessary. 7. Overhauling of the bed drive gear reduction unit. 8. Checking of associate dust work for air vapour tightness. 9. Detailed check of the air pressure balancing of the system / unit. 10. Detailed check of the performance of the system.

12

-

-

... More
M & L for point wiring with PVC insulated unsheathed 1100 Volts grade single core FRLS multistranded copper conductor cable 1.5 Sqmm drawn in and including PVC casing-caping and accessories, fixed on wall / ceiling etc with neccessary fixing accessories and earth continuity FRLS multistranded copper conductor cable size connected to common earth and earth dolly including 2 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws including taking down u/s wiring, fittings, switch, sockets etc all as specified for the following: Note:- All points to be made in Hangers/Sheds, hight up to 10 Meters only. Make of Wire : KEI/ Polycab/ Benlo/ Finolex Make of Conduit: Pressfit/ Sudhakar (a) For one light, fan, call bell, point controlled by one switch.

75

-

-

... More
(b) For one socket point controlled by one switch on same board

5

-

-

... More
(c) For one 5 Amp independent socket point controlled by one switch.

15

-

-

... More
All as per item No 78 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, multistranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, multi stranded 1100 volt grade cable as continuous earth lead.

15

-

-

... More
M&L circuit wiring in repairs with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 1.5 sqmm drawn in MS Steel conduit with 1.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI marked of size not less than 20 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable wiring complete. Note : 1. M S Conduit/ PVC Conduit will be measured and paid separately. 2. wiring in shed upto height of 6 mtr. 3. Three run of 1,5 Sqmm wire will be measured & paid as one unit. Make of Wire : KEI/ Polycab/ Benlo/ Finolex Make of Conduit: Pressfit/ Sudhakar

140

-

-

... More
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 2.5 sqmm drawn in MS Steel conduit with 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI marked of size not less than 20 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete. Note : 1. M S Conduitwill be measured and paid separately. 2. wiring in shed upto height of 6 mtr.3. Three run of 2.5 Sqmm wire will be measured & paid as one unit. Make of Wire : KEI/ Polycab/ Benlo/ Finolex Make of Conduit: Pressfit/ Sudhakar

60

-

-

... More
M&L sub main wiring in repairs with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 Sqmm drawn in MS Steel conduit with 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI marked of size not less than 20 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete. Note : 1. M S Conduit will be measured and paid separately. 2. wiring in shed upto height of 6 mtr.3. Three run of 4 Sqmm wire will be measured & paid as one unit. Make of Wire : KEI/ Polycab/ Benlo/ Finolex Make of Conduit: Pressfit/ Sudhakar

60

-

-

... More
S&F in repairs rigid metallic medium 20 mm dia stove enameled steel conduit ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position all as directed by Engineer-in-Charge. Make of Conduit: Pressfit/ Sudhakar/ Precision

230

-

-

... More
M&L sub main wiring in repairs with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 1.5 sqmm drawn in Existing surface/recessed MS Steel conduit/PVC Conduit with 1.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI marked of size not less than 20 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete. Note : 1. M S Conduit will be measured and paid separately if required on ground. 2. wiring in shed upto height of 6 mtr.3. Three run of 1,5 Sqmm wire will be measured & paid as one unit. Make of Wire : KEI/ Polycab/ Benlo/ Finolex Make of Conduit: Pressfit/ Sudhakar

120

-

-

... More
M&L sub main wiring in repais with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 2.5 sqmm drawn in Existing surface/recessed MS Steel conduit/PVC Conduit with 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid stove enameled steel conduit ISI marked of size not less than 20 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete. Note : 1. Additional M S Conduit/ PVC Conduit will be measured and paid separately if required . 2. wiring in shed upto height of 6 mtr.3. Three run of 2.5 Sqmm wire will be measured & paid as one unit. Make of Wire : KEI/ Polycab/ Benlo/ Finolex Make of Conduit: Pressfit/ Sudhakar

80

-

-

... More
M & L for Opening switch mounting plate, rectifying the defects in fittings and fixtures by tightening loose connections or taking down of unserviceable/burnt Piano Switches, fan regulators, 5 Amps Sockets, 15 Amps Sockets, 5 Amps Switch socket Commbination, 15 Amps Switch Socket combination, Fan Regulators. Note :- (i) The representative of the contrcator (Supervisor - 1 No, Electrician Skilled - 1 No, Helper - 1 No) shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contract period (ii) Replacement of defective parts/items will be measured and paid as supply and fix under respective items herein below.

230

-

-

... More
M & L for taking down of Light fittings such as 1 X 40 W, 1 X 20, 1x10 Watts tube light fittings, CFL light/LED fittings for repairs & refixing the same after carrying out repairs . Note :- (i) The representative of the contrcator (Supervisor - 1 No, Electrician Skilled - 1 No, Helper - 1 No shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contract period (ii) Tube Rod, CFL lamps, Choke & Starter required to be replaced shall be paid under respective item of this schedule as Supply & fixing. (iii) Minor spares such as holders, connectors, wires are deemed to be inclusive of the quoted rate.

140

-

-

... More
M & L for opening of MCB DB /MCCB DB front door & replacing of burnt wires & tesing comple after carrying out repairs . Note :- (i) The representative of the Contractor (Supervisor - 1 No, Electrician Skilled - 1 No, Helper - 1 No shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contract period (ii) MCCB & MCB required to be replaced shall be paid under respective item of this schedule as Supply & fixing. (iii) Minor spares such as connectors, wires, lugs are deemed to be inclusive of the quoted rate.

8

-

-

... More
M & L in repairs for rewiring of old burnt out copper wiring in LT Panels/LT Feeder, replacing of damaged cable Glands, burnt cable lugs, bus bar link, connectors, damaged insulators, burnt copper cables, door hinges, panel door locks & scrapping of old paints & applying two coats of paint all as directed by Engg-in Charge Make of paints : Nerolac/ Asian Paints/ Berger. Make of primer : Sheenlac/Asian/ Apcolite

1

-

-

... More
Supply & Fix in repairs switch piano single pole flush type 5A, 240 V one way complete. Make - Anchor/ Roma/ Havells

12

-

-

... More
Supply & Fix in repairs Bell push flush type 5 amp, 250 Volts complete. Make - Anchor/ Roma/ Havells

2

-

-

... More
Supply & Fix in repairs switch socket combination 2 in 1 , 5 Amps multipurpose flush type complete Make - Anchor/ Roma/ Havells

8

-

-

... More
Supply & Fix in repairs switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal. Make - Anchor/ Roma/ Havells

8

-

-

... More
Supply & Fix in repairs Ceiling rose surface bakelite three terminal, 240 V complete. Make - Anchor/ Roma/ Havells

30

-

-

... More
S&F, in replacement, electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete conforming/ ISI Marked all as specified. Make - Anchor/ Roma/ Havells

8

-

-

... More
Supply and fix in repairs bell ding dong AC 230 V single pole. Make - Anchor/ Roma/ Havells

2

-

-

... More
S & F in repairs Modular Socket 6 A, 2/3 Pin Combined, inclusive of modular cover plate & box as per combination of points Make - Anchor/ Roma/ Havells

18

-

-

... More
S & F in repairs Modular Socket 6/16 A, 2/3 Pin Combined inclusive of modular cover plate & box as per combination of points Make - Anchor/ Roma/ Havells

8

-

-

... More
S & F in repairs Modular Switch single pole 1 Way 6 Amps inclusive of modular cover plate & box as per combination of points Make - Anchor/ Roma/ Havells

18

-

-

... More
S & F in repairs Modular Switch single pole 1 Way 16 Amps inclusive of modular cover plate & box as per combination of points Make - Anchor/ Roma/ Havells

8

-

-

... More
S&F in repairs ULTRON LED polycarbonate T8 tube 20 Watt with in built driver with metal heat sink, Single/ double sided connection, 230 volts including fixing arrangements and taking down old unserviceable tube rod complete all specified and directed. Make-:Crompton / Havells /Bajaj/Jaquar/Wipro

325

-

-

... More
S&F in Repairs/Replacement Surface and wall mounted batten suitable for LED tube 20-22 watts, 230 volts, including fixing mounting blocks 2 Nos, 1.5 sqmm 3 core PVC insulated copper conductor cable including fixing arrangements and taking down old rusted bracket fittings complete all specified and directed. Make-:Crompton /Bajaj/Jaquar/Wipro

175

-

-

... More
Supply and fix in repairs decorative recessed type LED light fitting 35/36 watt (size 2'x2') 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, including making addition/altn to existing false ceiling and providing of false ceiling sheets, aluminium frames including fixing arrangements and taking down old rusted bracket fittings complete all specified and directed. Make-:Crompton /Bajaj/Jaquar/Wipro

15

-

-

... More
Supply and fixing in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete all as specified and directed. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO

25

-

-

... More
Supply & fix in repairs recess & surface LED 1 ft x 4 ft panel ceiling light fitting 40 Watt (SPAN) with high brightness SMD LED as light source and including driver unit, including provision of 3 core copper flexible cable size 1.5 Sqmm from ceiling rose to connector, including making addition/altn to existing false ceiling and providing of false ceiling sheets, aluminium frames including fixing arrangements complete all specified and directed. Make-:Crompton /Bajaj/Jaquar/Wipro

2

-

-

... More
Supply & fix in repairs LED Highbay light fittings 150 watts, Energy saving, environment friendly & robust open type vertical Highbay LED IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting. The fitting including fixing arrangements and taking down old rusted bracket fittings complete all specified and directed. Make-:Crompton /Bajaj/Jaquar/Wipro Note : Fittings shall will be installed in Hangers/Sheds, height up to 10 Meters only and directed by Engr-in-Charge.

2

-

-

... More
Supply Installation, Testing and Commissioning of LED Highbay luminaire 118 Watts with S nominal system lumen outpot Of 14300 lumens and a minimum system efficacy of 120 im/. The luminaire shall have a rated syatem lifetime of 50,000 buring hours at -70 The luminaire Should have a color temperature of 6500K and CRI 80 iuminaire shall meet IP65 rating with THD with THD 20% and PF 0.95 al iK07. The luminaire housing should made of High Pressure cie cast Aluminium with tempered glass and offering narrow beam optics with 2*50degree Rotationai symmetry beam (for high ceiling heights). The total power. consumption should not exceed 118W (including driver) Similar-to Philips Make MAXOLID "BY415P LED145S CW WB FG PSU GR or equivalent in Wiprol Jaquar" Fabricate,supply & fix GI pipe bracket 25mm dia- 0.9m long &2 set of clamps made out of 30.

15

-

-

... More
S&F in repair of building Security light fitting made up of pressure die cast alluminium body with mid power 35 Watt LED (PINNACLE PLUS) as lighting sources and PC cover having Top opening seperate driver compartment with IP66 protection Including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. Make-:Crompton /Bajaj/Jaquar/Wipro

4

-

-

... More
M & L in repairs for GI steel tubing medium grade 40mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 40mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge

20

-

-

... More
Supply & Fix in repairs MCCB DB TPN 4 Way double door prewired suitable for Triple Pole 125 A incomer MCCB with the following acessories including taking down u/s DB - a) MCCB TP 125 A 25 KA 415 Volt - 1 Nos b) Bus bar, Din rail , Neutral link Make - Havells/Indoasaian/Legrand/ABB/Schnider

2

-

-

... More
Supply & Fix in repairs MCB DB SPN 2 way 240 volts Single door, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider

2

-

-

... More
Supply & Fix in repairs MCB DB SPN 4 way 240 volts Double door 200 Amps rated bus bar, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider

2

-

-

... More
Supply & Fix in repairs MCB DB SPN 8 way 240 volts Double door 200 Amps rated bus bar, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider

2

-

-

... More
Supply & Fix in repairs MCB DB SPN 12 way 240 volts Double door 200 Amps rated bus bar, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider

2

-

-

... More
Supply & Fix in repairs TPN DB 4 way 415 volts Double door, including connecting up with existing cable with new lugs including taking down old u/s. The DB Shall be of Make - Havells/Indoasaian/Legrand/ABB/Schnider

2

-

-

... More
S&F in repairs single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 20 Amp 240 Volts including taking down old u/s complete all as specified and directed. Make - Indoasain/Legrand/Havells

8

-

-

... More
M&L in repairs for MCB SP, 240 volt, 5 to 32 Amps, 10 KA, C Curve, including taking down old u/s complete all as specified and directed. Make - Indo Asian/Legrand/ ABB/Schnider/Havells

35

-

-

... More
M&L in repairs for MCB SPN, 240 volt, 40 to 63 Amps, 10 KA, C Curve, including taking down old u/s complete all as specified and directed. Make - Indo Asian/Legrand/ABB/Schnider/Havells

25

-

-

... More
M&L in repairs for MCB TPN, 240 volt, 40 to 100 Amps, 10 KA, C Curve, including taking down old u/s complete all as specified and directed. Make - Indo Asian/Legrand/ABB/Schnider/Havells

3

-

-

... More
Taking down old unserviceable High bay, Mid Bay, Flame Proof light fittings from walls/Builings/Sheds/Ceiling height up to 10 Meter for repairs and replacement of burnt/worn out accessories and refixing the same in existing position including testing of fittings after repair, testing of connected wiring complete all as directed by Engineer in charge . Note :- (a) T & P, Ladder for any height etc are deemed to be included in the quoted rate. (iii) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contrcat period and the defect shall be rectified on the same day (iii) A penal recovery of Rs 500 Per Day Per Complaint for not attening the compalint will be recovered

10

-

-

... More
Supply and fixing Post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp including removing old unsv lights complete. Make:- Bajaj/ Havells / Benlo/ Crompton/ Jaguar/ Wipro

2

-

-

... More
Supply and fixing Post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp including taking down old u/s light fitting complete. Make:- Havell's/ Crompton/ Jaguar/ wipro/ Bajaj/ Benlo

2

-

-

... More
S&Fix in replacement Flameproof wall mounted outdoor type double door LT Panel made out of 3 mm thick CRCA Sheet, the panel shall be provided with flame proof MCB DB made out of Cast aluminium alloy LM6, inside and out side light gray epoxy powder coating shade, with 1 No cable entry for incoming cable and three Nos cable entry for out going circuits with and including cable gland and stopping plug, 1 No MCB SPN 32 Amp as incoming and 3 Nos MCB SP6 Amps for out going connections IP 65 protection as per IS 2147/1962. The panel shall be powder coated, front openable and locakable with key and shall be fabricated from CPRI approved sample manufacturer including taking down old u/s Panel complete all as specified and directed. Make- Sudhir /Flexpro /Baliga /crompton greeves/ Shyam Switch Gear Note - The contractor shall submit the Layout Drawing of Panel and got approved by GE before the panel fabrication

1

-

-

... More
Supply & fix in repairs UPVC panel trunking of size 25 mm X 25mm including spacers, screws, saddles for fixing the trunking in wall/GI sheets of shed Make - Precision Cat No PPT 2525 or Equivalent from Presto Plast/Finolex

14

-

-

... More
Supply & fix in repairs UPVC panel trunking of size 45 mm X 45mm including spacers, screws, saddles for fixing the trunking in wall/GI sheets of shed Make - Precision Cat No PPT 4545 or Equivalent from Presto Plast/Finolex

14

-

-

... More
Supply & fix in repairs UPVC panel trunking of size 100 mm X 100mm including spacers, screws, saddles for fixing the trunking in wall/GI sheets of shed Make - Precision Cat No PPT 100100 or Equivalent from Presto Plast/Finolex

14

-

-

... More
Supply & fix in repairs UPVC panel trunking of size 300 mm X 100mm including spacers, screws, saddles for fixing the trunking in wall/GI sheets of shed Make - Precision Cat No PPT 100100 or Equivalent from Presto Plast/Finolex

14

-

-

... More
M & L for taking down of LT XLPE insulated, armoured heavy duty 1100 volt grade electric cable with aluminium conductor of size 2 Core 10 Sqmm to 3.5 Core 35 Sqmm from wall/Roof/steel Structures of buildings/Storgae Sheds etc and refixing the same in position after replacing of Saddles & Spacers all as directed by Enginner incharge including replacing of cable glands, lugs & making all connections complete as required at site and as directed by Engr-in-Charge. Make - KEI/ Polycab/ Gloster/ Havells

60

-

-

... More
Supply and Fix in repairs CIMFR certified LED flame proof well glass light fitting 60 watts , with driver & LED, IP 65 protection, including connecting up with three core flexible multi strand copper conductor of 1.5 Sqmm, with flexible metal conduit, including including fabricating red oxide coated brackets made out of MS angles/MS flat for fixing the fitting up to one meter below permenent ceiling, including anchor fastners, nut, bolts, hooks, chain etc including taking down old u/s fitting. The Fitting Shall Conform to Make : Crompton/ Shyam Switch Gear /Bajaj / Sudhir Note : (a) Fittings shall will be installed in Hangers/Sheds, hight up to 6 Meters only and directed by Engr-in-Charge. (b) T & P, Ladder for any height etc are deemed to be included in the quoted rate.

5

-

-

... More
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10 - 60Amp suitable for single phase, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as directed by Engr-in - Charge .Make - L&T / HPL / ABB/ Benlo

10

-

-

... More
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.

36.45

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.

19.04

-

-

... More
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.

17.42

-

-

... More
M & L for sand cushioning by spreading in trenches fine crush sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.

14.58

-

-

... More
Supply and laying in repairs un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified. Make: MEHTAB /NATIONAL TILES

480

-

-

... More
Laying only un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified. Note :- Serviceable cable cover obtained here-in-after shall be reused.

720

-

-

... More
Dismantling only in repairs of PCC foundation / pole coping from ground level all as per specified.

2.28

-

-

... More
M & L in repairs for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed.

2.28

-

-

... More
Supply and Laying in repairs or fixing or passing through pipe, XLPE insulated ISI marked, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 35 Sqmm 3.5 core including necessary connection and providing cable lugs as required including disconnection/taking down of existing cable all as specified. Make: Polycab/ Havell's/ KEI/ Gloster

180

-

-

... More
Supply & Fix of Lithium Based Integrated Solar in FRP Body all in one integrated solar street light 40 Watt white LED type with IP 66 or better ingress protection with inbuilt lithium ion battery 11.1 V/ 12.8 V 39.6 Ah, provide with 2 LED indicators: a green light to indicate charging in progress and a red LED to indicate depp discharge condition of the battery, green LED glow only when the battery is being actully charged, batery included in the luminary enclosure, with water proof i.e. IP 66 or better and corrosion resistant, material of construction of solar light fitting shall be FRP, LED lamp 40 watt (W-LED, 180-200 mn/watt, CRI70) with 120Degree vide angle lens for better light distribution and colour temp-5700-6500K, Solar PV Module mono crystalline, = 82 Wp. Make : SAIAPL or equivalent

1

-

-

... More
Supply and fix air termination, single pointed aluminium rod 12mm dia and 300 mm long, including base plate complete with all screws, nut/bolts.

24

-

-

... More
S & F test poing terminal block made of gun metal or phosphours bronze size 75 x75 x25 mm drilled and screwed including 3 nos . 8 mm dia 25 mm long hex. Head screw.

6

-

-

... More
S & F Aluminium strip 25 X 3.15 mm with saddles and supporting insulator fixed with non-corosive screw/nut, bolt etc. for roof conductors and down conductors above ground.

160

-

-

... More
M&L for pre-cast cement concreate block of size 0.15M x0.15M x0.30 M for fixing of roof conductor Aluminium strip type C1 1:3:6 using 20mm graded stone aggregate in cement motor 1:4.

1.6

-

-

... More
M&L for earthing complete with GI earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal gound level and connected to earth test point by means of GI Strip of size 32x6 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including earthwork, PCC chamber, CI cover, protection and watering pipe, funnel, mesh etc all as required at site and all as directed. Note: (1). 7.5 RM GI strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately (2) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of GI earth plate.

4

-

-

... More
Material and labour in repairs for attending breakdown and rectification of faults detected of existing upto 300 LPD roof top solar power water heater system, Re-assembling the solar water heater assambly and re-install at same position and testing complete installed as per following. Make: Racold (a) Capacity of Solar Water heater: 100 LPD (b) Location: NSB /NOFRA, (Total 4) (c) Capacity of Solar Water heater: 200 LPD (d) Location: NSB /NOFRA (Total 9) (e) Capacity of Solar Water heater: 300 LPD (f) Location: Godavari, Kaveri NOFRA (Total 4)

8

-

-

... More
Material and labour for comprehensive systematic maintenance and periodical inspection service of existing up to 300 LPD Roof top solar water heater system by the trained and qualified employee to provide routine maintenance, examination, according to recommended schedule of maintenance/ service for once in a month during working hours (i.e. Monday to Saturday 0900 hours to 1700 hours) except scheduled holidays to undertake the necessary examination including checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc. in situ to ensure proper functioning of parts including supply and checking serviceability of individual componenets and replacement of worn out fasteners, gaskets, washers accessories, inspection of the entire system, cleaning of sacrificial anode, rectification of any leaks, tightening of electric loose connections, etc complete all as specified and as directed by the Engineer-in-charge. Make : Racold (a) 100 LPD plant at NSB/NOFRA (Total 4)

6

-

-

... More
(b) 200 LPD plant at NSB/NOFRA (Total 9)

6

-

-

... More
(c) 300 LPD plant at Godavari, Kaveri, NOFRA (Total 4)

6

-

-

... More
Supply and fix heating elements of capacity 3 KW AC 240 volts (as per existing sample) ISI marked suitable for solar water heater of capacity 100ltr to 500ltr capacity as per requirement (press type/ screw type/ triangular/ circular base or ceramic cartige type) including taking down unserviceable complete all as specified and as directed.

50

-

-

... More
S&F 25 mm bore GI tubing medium grade with all fittings such as bends, socket, tee, elbows, union, barrel, nipple, plugs etc fixed to walls and ceilings or laid in floors with suitable size GI clamps including taking down old GI tubing including fittings complete all as specified.

70

-

-

... More
S&F 20 mm bore GI tubing medium grade with all fittings such as bends, socket, tee, elbows, union, barrel, nipple, plugs etc fixed to walls and ceilings or laid in floors with suitable size GI clamps including taking down old GI tubing including fittings complete all as specified.

60

-

-

... More
S&F 15 mm bore GI tubing medium grade with all fittings such as bends, socket, tee, elbows, union, barrel, nipple, plugs etc fixed to walls and ceilings or laid in floors with suitable size GI clamps including taking down old GI tubing including fittings complete all as specified.

60

-

-

... More
S&F in repairs gunmetal gate or globe valve for 25mm dia, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing,a including taking down old unserviceable gate or globe valve complete all as specified and as directed

10

-

-

... More
S&F in repairs gunmetal gate or globe valve for 20mm dia, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing,a including taking down old unserviceable gate or globe valve complete all as specified and as directed

10

-

-

... More
M& L for supplying, hoisting and fixing rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) as per IS 12701-1996 (Reaffirmed 2006) of 500 Litres capacity with virgin food grade plastic, UV stabilized tank and lid, two layers protection with black outer layer for superior UV protection and white inner layer to see water leval and tank condition including covers, hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes etc complete all as specified and as directed. Make-: Sintex/ Reno/ Plasto / Supreme

8

-

-

... More
Supply, install, testing and commissioning of solar panel flat plate collector type based on direct transfer of heat of capacity upto 300 LPD, producing temperature upto 80 degree centigrade including fixing arrangement and providing connections as per existing including distmantling existing Solar Panel of any capacity complete all as specified and as directed by Engineer-in-Charge. Make - RACOLD (OMEGA), THERMAX LTD, VENUS, MACHINO CRAFT, BRITTO

6

-

-

... More
Supply and fixing in repairs hot water tank of capacity 100 ltrs,SS-304, including provision for inlet and out let of hot water, pressure release system.Hot water tank shall be made of 5 mm thick MS sheet duly insulated with glass wool / rock wool / Puf, aluminium / stainless steel cladding all around the tank and heat exchanger compartment etc complete.

2

-

-

... More
Supply and fixing in repairs hot water tank of capacity 200 ltrs,SS-304, including provision for inlet and out let of hot water, pressure release system.Hot water tank shall be made of 5 mm thick MS sheet duly insulated with glass wool / rock wool / Puf, aluminium / stainless steel cladding all around the tank and heat exchanger compartment etc complete.

3

-

-

... More
Supply and fixing in repairs hot water tank of capacity 300 ltrs,SS-304, including provision for inlet and out let of hot water, pressure release system.Hot water tank shall be made of 5 mm thick MS sheet duly insulated with glass wool / rock wool / Puf, aluminium / stainless steel cladding all around the tank and heat exchanger compartment etc complete.

4

-

-

... More
S&F in repair MCB, single pole & neutral 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.

10

-

-

... More
S&F 1100V grade heavy duty XLPE armoured cable, PVC insulated Al conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection of size 6sqmm, 3 core cable complete all as specified and as directed

50

-

-

... More
M&L thermostat of Type EST 11/20A, 240 Volt of ISI marked approved make complete all as specified and directed.

12

-

-

... More
M&L thermostat of Type EST 7/15A, 240 Volt of ISI marked approved make complete all as specified and directed.

12

-

-

... More
Supply and fix in repair 25 mm bore PVC Ball valve ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron rod and fixed complete all as specified and directed. Make -: Prayag / Shakti / Airaeuro / Agrotech / Teleflo / Techno International

20

-

-

... More
M & L for rolled mild steel in joist,channel,angle or tee sections in framework for staging of water tank, solar panel etc including all necessory drilling, bolting,riveting or welding conforming to Fe-290 (Gde E-165) and embeding the supportin PCC bed block on roof top with suitable size FI hold fast including dismantling carefully existing staging complete all as specified. Note - The staging for water tank/solar panel shall be embedded in PCC block provided over RCC slab. No drilling in RCC slab shall be allowed for fixing staging and any damage due to any reason shall be made good by the contractor at his own cost.

100

-

-

... More
M&L PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in bed blocks/ pedestals for support of water tank staging support, solar panel supports including necessary formwok complete all as specified.

3

-

-

... More
M & L for Hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore complete all as secified and as directed

12

-

-

... More
S&F of 3 Phase Solar water Heater control panel of capacity 230V, 50 Hz, having provision for Start/Stop switch ,RYB indicators, Auto Manual switch,ML2 Series 32A AC3 415V 50HZ, 40A AC1 IS4EC 60947-4-1 contactor, Selec TC344 Temperature panel indicator with sensors ,connectors and MCB capacity C40 TPN, SP MCB C6 4 in Nos with Control wiring complete all as specified and directed by Engineer- in -charge. Note : A sum of Rs 76187.00 towards sch of credit shall be deducated to arrive the contract sum.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.