Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date24 Jan 2025
Closing Soon13 Feb 2025
Tender Amount₹ 48,06,000
Costs
EMD
₹ 96,120Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_694758_1Tender No
8152/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Rolling to Soling of broken boulder or quirried stone n.exc. 15 cm thickness using 8 to 10 ton Power roller complete all as specified and directed.
35
-
-
... More
M&L for polythene film ,black ,50 micron laid in floors complete all as specified and directed.
350
-
-
... More
M&L PCC (1:4:8) D-2 40mm graded aggregate in sub base 150 mm thick complete all as specified and directed.
350
-
-
... More
M&L PCC 1:11/2 :3, type B 1 100 mm thick in floors complete all as specified and directed.
350
-
-
... More
M&L for forming Construction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound joint 30 mm deep X 10 mm wide filled with sealing compound, Grade 'A' complete all as specified and directed.
17
-
-
... More
M&L for machine pressed precast concrete inter locking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade, glossy finished of approved colour laid over and including 25 mm thick fine sand cushion to a line and slope etc and joined complete including spreading screened river sand over surface for filling the joints with rising surface vibrator etc complete all as specified and directed.
350
-
-
... More
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
52.5
-
-
... More
M & L for 20-25mm thick, machine cut, Kota stone slab, as in floors, steps, landing etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of slab, including cutting, polishing etc. with and including 20mm thick screed bed in CM 1:4 complete all as specified and directed.
100
-
-
... More
M &L for machine cut kota stone slab 18 to 20 mm thick as in skirting/vertical surfaces jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and 15 mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
5
-
-
... More
Taking down cement plaster on brick walls or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc including removing debries directed for a distance max upto 500m complete all as specified and directed.
300
-
-
... More
M&L for rendering 15mm thick in CM 1:6 on brick work or concrete surfaces finished even and smooth with using sagol finish complete all as specified and directed.
150
-
-
... More
M & L for preparing new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whitening on plastered surfaces complete all as specified and directed.
150
-
-
... More
M&L prepration of old plastered / decorated surfaces of walls and applying two coat of oil bound distemper on plastered/decorated wall surfaces complete all as specified and directed.
80
-
-
... More
M&L Plastering 5mm thick in CM 1:3 on concete surfaces as in ceiling finished even & smooth without using extra cement in ceiling complete all as specified and as directed .
90
-
-
... More
M&L for rendering 15 mm thick pre polymer modified ready mixed cement based plaster in two coats 10 mm thick base coat and 5 mm thick finishing/final coat. Polymer modified ready mixed cement based plaster should having minimum composition of cement & sand 1:4 using fully treated dry, well graded natural sand conforming to IS-383 suitable for external plastering having low rebound properties, low water demand for curing properties, mechnical mixing with water in a matalic tray only to made good, consistency as per the specification of the manufacturer and applied over exterior masonry and concrete surfaces incl using richer mix for making corners if necessary incl making grooves of existing size and necessary two legged MS pipe scaffolding as wherever required incl curing required complete all as specified and directed.
60
-
-
... More
M&L for new or previously untreated surfaces of any description & applying two coats of acrylic (antifungal) exterior grade paint of over one coat of primer on wall/roof complete all as specified and directed
60
-
-
... More
M & L preparation of new plastered surfaces and applying three coat of white wash on ceiling complete all as specified and directed.
90
-
-
... More
M & L for Complete removal of existing treatment of walls and applying two coats of acrylic (antifungal) exterior grade paint of over one coat of primer on wall/roof including necessary scaffolding complete all as specified and directed
30
-
-
... More
Demolition of brick work/stone masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles including coping complete all as specified and directed.
10
-
-
... More
Excavation in trenches not exc 1.5 m wide in for foundation etc getting out in hard dense soil complete all as specified and directed..
33.75
-
-
... More
Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
3.75
-
-
... More
M&L for PCC 1:4:8 type D2 using (40mm graded stone aggregate) as in sub base, foundations, fillings & mass concrete and haunching of pipe etc complete all as specified and directed.
5.63
-
-
... More
M&L brick work with sub class 'B' bricks old size, straight or curved on plan exc 6m mean radius in cement mortar 1:4 complete all as specified and directed.
10
-
-
... More
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in concrete bed 150 mm dia pipe including packing under and haunching against the sides of pips after they are laid and tested complete all as specified and directed.
50
-
-
... More
M&L 150 mm bore (Bore of pipe in mm) reinforced concrete pipes, class NP-2 laid and jointed complete with collars complete all as specified and directed.
50
-
-
... More
S&F for Cast iron work grade FG 150, Articles exc 5kg unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles etc complete all as specified and directed.
3400
-
-
... More
M&L PCC (1;2:4) type B-1 using 20mm graded stone agregete as in coping complete all as specified and directed.
2.5
-
-
... More
Returning and filling in including spreading, levelling, watering and well rammed in layers not exec 25 complete all as specified and as directed as in hard/dense soil complete all as specified and as directed.
20
-
-
... More
S &F 160 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/floor complete all as specified and directed.
100
-
-
... More
S&F for PVC (SWR) bends any radius 160mm bore complete all as specified and as directed
20
-
-
... More
M&L for 100m dia cast iron soil waste pipes (sand cast pipes) in any length with or without ears with cement joints including CI pipe collar wholseal fixed to walls/floor complete all as specified and directed.
60
-
-
... More
S&F CI bends for 100mm dia pipe (any radiius) diminishing pieces or trapers (larger bore measured) fitted with oval access doors complete all as specified and directed.
10
-
-
... More
Taking down existing mild steel rolling shutters for and including replacing the slates, bottom lock plates, helical springs, side guides, sponge rubber gaskets, hood cover and side bracket etc wherever required and refixing in its original position after repairs/replacement including material and labour for greasing and mechanical parts of rolling shutters complete all as per directed for shutters of area n. exc 10 sqm each, complete all as specified and directed.
4
-
-
... More
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, fixed with self tapping screws complete all as specified and directed.
15
-
-
... More
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, valley gutter, ridge and fixed with crumple joint etc fixed with self tapping screws complete all as specified and directed.
3
-
-
... More
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, ,removing material to store for keeping in safe custody and making good to disturbed surfaces complete all as specified and directed.
266
-
-
... More
M&L for concealed point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC Conduit with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth dolly including modular box and cover plate for One light point point controlled by one 5A switch all as specified.
Notes:
a) Colour coding shall be followed as given below:- i) Phase - Red ii) Neutral - Black iii) Earth - Green B) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
129
-
-
... More
All as per item No. 40 but for One Fan point/Exhaust fan point controlled by one 5A switch
72
-
-
... More
All as per item No. 40 but for One 5A switch socket point on same board
25
-
-
... More
All as per item No. 40 but for One 5A flush type switch socket point on independent board
28
-
-
... More
M&L for casing capping point wiring complete with 2.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make drawn through & including PVC Conduit with Accessories fixed on wall/ceiling/truss etc with metallic ISI make terminal boxes fix on wall including one PVC insulated & unsheathed multistranded copper conductor 2.5 Sq. mm as earth continuity conductor connected to common earth dolly for single board having 1 x15 Amp switch socket point for independent board complete including required size and numbers moduler box and cover plate all as specified & directed. Notes:-
a) Colour coding shall be followed as given below:- i) Phase - Red ii) Neutral - Black iii) Earth - Green
12
-
-
... More
S & F ceiling rose surface bakelite 65 x 50mm, flush type, 3 terminals complete all as specified and directed .
141
-
-
... More
S & F modular switch 1 way 6A complete all as specified and directed .
254
-
-
... More
S & F modular switch 1 way 15A complete all as specified and directed .
12
-
-
... More
S & F modular socket, 6A - 2/3 pin combined 2 modules complete all as specified and directed .
53
-
-
... More
S & F modular socket 16A, 2 module complete all as specified and directed .
12
-
-
... More
S&F for modular fan step regulator, 120W - 2 modular complete all as specified and directed .
2
-
-
... More
Supply and fixing in repair new generation slim recessed LED 2X2 Luminaire 36 watt and CRCA powder coated body and high translucent diffuser provides high quality ecomonic energy saving lighting to modern offices. Suitable for 600 x 600 mm modular/POP/Gypsum ceiling complete all as specified and directed .
10
-
-
... More
Supply and fixing in repair walll/surface mounted 20W LED batten fitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round/square block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed .
15
-
-
... More
Supply and fixing in repair of LED 90W Street/building security light fittings with high pressure die cast housing with toughened glass and individual LED with secondary optics and IP66 protection complete all as specified and directed .
4
-
-
... More
S&F in replacement of MS arms bracket (BEST-Pattern) for mounting one in Nos Street/Building security light fitting 40 mm medium grade GI at an angle of 120 degree including clamp/nut/bolts & washers to brace the same properly with duky painted in synthetic enamel paint of two coat in silver colour complete all as specified & directed .. NOTE : Contractor deemed to be included the making the good to the disturbed surfaces to match with the existing.
4
-
-
... More
Taking down and Supply and fixing in repair Distribution Board double door, prewired type, made out of CRCA mild steel surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN DB 08 Way ,240V with bus bar rating 100Amps, dust and vermin proof suitable for incorporation of MCB'S and isolators etc, complete all as specified and directed .
9
-
-
... More
S & F in replacement of MCB SP 6-32 Amps,10KA, 'C' series 240V, with over load and short circuit protection and rapturing capacity not less than 10KA complete all as specified and directed.
12
-
-
... More
S & F in replacment of MCB SPN 40 to 63 Amps,10KA 'C' series 240V complete all as specified and directed.
3
-
-
... More
S & F in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete suitable for one single pole MCB 20A all as specified and directed .
20
-
-
... More
M&L for concealed sub-main wiring with 2 runs of 4.0sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing & caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) 2 runs of 4 Sqmm cable and one run of PVC casing caping shall be measured as one unit.
220
-
-
... More
Supply , fixing, testing in repairs of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( avera Schneider ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof incl all as specified .
Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
1
-
-
... More
M&L for sub-main wiring with 2 runs of 2.5sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC casing & caping not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 2.5sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location,complete all as specified and directed.
Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/Gloster. (c) Make of PVC casing capping:- precision/ pesto plast/ national/plaza.
(d) 2 runs of 2.5 Sqmm cable and one run of PVC casing caping shall be measured as one unit.
90
-
-
... More
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor, complete all as specified and directed.
35
-
-
... More
Taking down and Supply and fixing in repair exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers,complete all as specified and directed .
4
-
-
... More
Taking down and Supply and fixing in repair exhaust fan, steel body AC single Phase. 230V of size 600mm sweep with, blades, and frame and louvers,complete all as specified and directed .
6
-
-
... More
Taking down and Supply and fixing in repair wall mounted fan,400mm sweep,complete all as specified and directed .
25
-
-
... More
Taking down and Supply and fixing in repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose,complete all as specified and directed .
100
-
-
... More
Taking down and Supply and fixing in repair of double door type vertical type TPN DB 8 Way ,240V with 200A busbar , with metalic double door type IP 43 IK 09 protection suitable for housing MCCB's,complete all as specified and directed .
2
-
-
... More
Supply and fixing in replacement, MCCB FP 100 Amps,16KA, complete all as specified and directed.
2
-
-
... More
S & F in replacement of MCB, C Curve type suitable for 415 volts AC supply, TP 24 to 63A with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection, complete all as specified and directed.
4
-
-
... More
S & F in replacement of MCB, B Curve type suitable for 240 volts AC supply, SP 5 to 32A with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection,complete all as specified and directed.
66
-
-
... More
S & F in replacement of MCB, B Curve type suitable for 240 volts AC supply, SPN 40 to 63A with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as directed.
6
-
-
... More
Supply and in repair of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 32 mm dia with 250 micron ( average ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF ECO SAFE compound shall be supplied in 50 Pound Bag. ( 1 Bag required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set incl Supply of Eco Friendly weather proof High Density Polyethylene Earth Pit Chamber Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
2
-
-
... More
Disconnecting and carefully taking down of existing capacity outdoor units of chiller plant from existing position all as specified and directed .
7
-
-
... More
Supply, fixing and testing of outdoor double decker wall mount type metalic stand of suitable size for fixing existing outdoor unit of chillers for cold room including provision of weather proof tin shed of suitable size over the stand complete all as specified and directed by Engr-in-Charge. Note : (i) The design and size for the outdoor stands to be approved from Engr-in-Charge. (ii) The cost of plaster work, PCC, etc required to make good as per existing is deemed to be included in quoted rate.
2
-
-
... More
Supply and fixing of outdoor units stand suitable to fit 03 Nos outdoor units of chiller for cold room complete all as specified and directed. Note : (i) The design and size for the outdoor stands to be approved from Engr-in-Charge. (ii) The cost of plaster work, PCC etc required to make good as per existing is deemed to be included in quoted rate.
1
-
-
... More
Material and labour for re-installation of outdoor unit for chiller rooms over the outdoor stands complete all as specified and directed .
7
-
-
... More
Supply, fixing and jointing copper tubing of appropriate dia for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through and making good to the disturbed surface complete all as specified and directed.
325
-
-
... More
Supply and laying in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 16 sq mm 4 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. Note : 1. The cost of thimbles/lugs, clamping and cable gland etc is deemed to be included in quoted rate.
160
-
-
... More
Supply and laying in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 50 sq mm 4 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. Note : 1. The cost of thimbles/lugs, clamping and cable gland etc is deemed to be included in quoted rate.
95
-
-
... More
S& F GI cable tray perforated type 2 mm thick of size 250x50mm ( Including pre fabricated GI clamp suitable for fixing/supporting ) with 0.71mm thick aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter cable trucking for plain to be fixed on any wall (brick/stone) vertically/horizontally including all accessories complete bending,shaping,drilling,welding, cutting & all fixing arrangement complete etc all as directed
50
-
-
... More
Material and labour for pressure testing, evacuation, gas charging and commissioning of indoor and outdoor units of chiller for cold room complete all as specified and directed .
7
-
-
... More
Supply and fixing rigid PVC pipe 25 mm dia for drain out condensing water of split AC including cutting of floor / opening of hole in wall and making good after laying of pipe etc to match the existing surface complete all as specified and directed.
150
-
-
... More
Supply and charging only refrigerant gas (R-22/R-410A/R-132A/134A) suitable as per site requirement complete all as specified and directed.
40
-
-
... More
Material and labour for weather proof tin shed of suitable size for protection of electrical junction box/DB's etc complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
Supply, install, Test and commissioning wall mounted Split type AC 1.5 TR capacity units indoor/outdoor complete with cordless remote control unit, 220-240 volt, 50Hz, single phase fitted with high quality rotary compressor and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating complete as directed. Note : (a) Rate of supporting brackets for outdoor unit is deemed to be included in rate quoted. (b) Note Windows AC is removed then space is covered to be included in rate quoted.Make : Daikin/Hitachi/LG
6
-
-
... More
Supply, install, Test and commissioning Floor mounted Tower type AC 3.0 TR capacity units indoor/outdoor complete with cordless remote control unit, 410-415 volt, 50Hz, three phase fitted with high quality rotary compressor and with in built air ioniser and Plasma filter for better indoor air quality with maximum 5 star rating complete as directed. Note : (a) Rate of supporting brackets for outdoor unit is deemed to be included in rate quoted.
2
-
-
... More
M&L for submain wiring with 4 runs of 6 sqmm and two run of 6 sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable with proper colour coding drawn through and including non metalic PVC casing & caping not less than 25mm width ISI marked with all accessories like PVC elbow, PVC Tee etc fixed on wall complete including connecting up all as specified and directed. Note: 4 run of 6 Sqmm cable and one run of PVC casing & caping shall be measured as one unit.
50
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%