Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 May 2024
Closing Date14 Jun 2024
Tender Amount₹ 38,82,000
Costs
EMD
₹ 78,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_655920_1Bid Award Id
ViewTender No
GE/LONAVLA/8235/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
One 3 pin socket outlet, 5 Amp on the same board with other switches
15
-
-
S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
15
-
-
S & F switch piano, 15 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
60
-
-
S & F socket out let, 2 in 1, 3 pin, 5 Amps, 240 volts complete all as specified and directed.
15
-
-
S & F Switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and directed.
20
-
-
S & F Ceiling rose, 3 way PVC insulated body complete all as specified and directed by engineer in charge.
60
-
-
Supply and fixing energy saving, envroment friendly & robust mediumby/Hiighbay LED luminaire with high efficacy (100 im/W) with toughened glass. Make : havells cat no- GAZELLAHBP100WLED857PBOTG or equivlent Philips/Bajaj. Note: All Highbay light hanging with truss ,all wiring done in casing caping or in condute as per site required,additional accesories price including in this rate.
40
-
-
Supply and fixing Higher wattage flood light luminaire with ultra sleek, light weight and secondary optics,made of pressure die cast housings with IP66 ingress protection and impact resistance of IK07.4kv inbult and 10kv external surge protection .Make : Bajaj (BJFL 150W LED I ) or equivalent philips/Havells.
20
-
-
Supply and fixing Higher wattage warm white flood light luminaire with ultra sleek, light weight and secondary optics,made of pressure die cast housings with IP66 ingress protection and impact resistance of IK07.4kv inbult and 10kv external surge protection .Make : Bajaj (BJFL 150WW LED I ) or equivalent philips/Havells...
6
-
-
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Crompton or equivlent Bajaj/Philips/Havells
55
-
-
Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface.
1120
-
-
Supply and fix FR PVC insulated cable 1100 V grade with multistranded copper conductor of size 2.5 Sqmm 3 core conductor all as s specified and directed by Engineer-In -Charge at site
320
-
-
S&F in replacement MCB DB TPN 4 ways double door with 440 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
1
-
-
S&F in replacemen MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
6
-
-
S&F in replacemen MCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
6
-
-
S&F in repairs MCB SPN 40 to 63 AMP, 240 Volts 10KA 'C' curve , Complete all as specified and directed.
12
-
-
S&F in repairs MCB SP 5 To 32 AMP, single pole 240 Volts 10KA 'C' curve, Complete all as specified and directed.
20
-
-
S&F in repairs MCB 415V 10KA 'C' Curve TPN 16 To 32 AMP , complete all as specified and directed.
4
-
-
S&F in repairs MCB 415V 10KA 'C' Curve TPN 40 To 100 AMP , complete all as specified and directed.
2
-
-
S&F in repairs MCCB FP 125 Amps 16 kA 415 V , wcomplete all as specified and directed.
1
-
-
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x2.5 sq. mm + 1x2.5 sq. mm earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:- Two run of 2.5 sqmm wire and One run of 2.5 sqmm wire and One run of PVC casing caping will be measured as one running meter.
420
-
-
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x4 sq. mm + 1x4 sq. mm earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:- Two run of 4 sqmm wire and One run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter.
380
-
-
S & F Outdoor Type, weather and vermin proof Bus bar panel made out of 2 mm thick stainless steel sheet including four pole 200 Amps MCCB 415 Volts 50 Hz with front opening and locking arrangement, 200 Amps capacity aluminium bus bar for phase, 3 No's and 1 No 200 Amp bus bar for neutral, mounted on epoxy insulator including neccessary copper control wiring, heat shrinkable, RYB coloured sleeves over bus bar for identification, earth shields, circular holes at bottom / top to receive incoming and outgoing cable, cable lugs, cable gland of sizes as required floor mounting angle iron frame made out mild steel angle iron of size 40 x 40 x 6 mm grouted on PCC (1:3:6) upto required height all as specified and as directed by Engr-In-Charge .
3
-
-
M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
15
-
-
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in soft/loose soil including making the bottom of trenches levelled for proper laying of pipe line, foundation etc or for shafts, cesspits, manholes, pier hole etc not exceeding 10 sqm on plan and getting out in soft/loose soil as as specified and as directed.
475.8
-
-
Removing the excavated material not exc 50 M and depositing where directed at a level not exc 1.5 above the starting point in soil complete all as specified and as directed.
50.3
-
-
Returning and filling including spreading, levelling watering and well ramming in layers not exceeding 25 CM in soil complete all as specified and as directed.
425.5
-
-
Taking up Cast iron water main of size any dia including all fittings for spigot and socket ends and lead joints including burning out lead joint and recovering lead complete all as specified as directed. Note :- (i) Excavation earthwork shall be measured and paid seperately
60
-
-
S&F cast Iorn Pipes with Spigot and Socket ends centrifugally cast, Class LA laid in trenches including reducing the length of required size complete all as specified as directed for following size of CI pipe :- Note :- (i) Excavation earthwork shall be measured and paid seperately. (ii) CI fitting will be measured and paid seperately.
a. 250 mm bore.
10
-
-
b. 200 mm bore.
15
-
-
c. 150 mm bore.
15
-
-
d. 100 mm bore.
10
-
-
e. 80 mm bore.
10
-
-
S&F cast iron fitting for spigot and socketted cast iron pipe such as bend, tees, pieces, joint piece single branches, junction colar branches, cap plug etc for size upto 150 dia pipes complete all as specified and as directed.
50
-
-
Ditto all as per item No 06 above but of size exceeding 200 mm to 300 mm dia.
50
-
-
M&L for run lead jointing of CI pipes including making working pits for carrying out lead jointing and necessary excavation and earth work as required for following size of CI pipes with spigot and socket ends complete all as specified and as directed :-
a. 250 mm bore.
1
-
-
b. 200 mm bore.
1
-
-
c. 150 mm bore.
1
-
-
d. 100 mm bore.
1
-
-
e. 80 mm bore.
1
-
-
M & L for brick masonary valve pit chambers with and including one brick thick masonary built in cement mortar (1:6)) PCC in foundation 1:4:8 type D2 (using 40 mm graded stone aggregate, rendering 10 mm thick in cm 1:6 internally 10 mm thick rendering in cement mortar (1:4) finished even and fair externally, PCC 1:2:4, type B1 (Using 20 mm graded stoneaggregate) for coping 10 cm thick, 6 mm thick MS plate cover with locking arrangements with angle iron frame of size 40x40x6mm including painting to MS work with two coats of synthetic enamel black paint over one coat of red oxide primer including necessary excavation and earth in any type of soil/strata complete for following sizes :-
a. Internal dimension 600x600x600mm.
1
-
-
b. Internal dimension 900x900x900mm.
1
-
-
c. Internal dimension 1050x1050x1050mm.
1
-
-
Taking down unserviceable GI pipe line of following size from the trenches by removing of nut and bolts.
a. 100 mm bore.
30
-
-
b. 80 mm bore.
80
-
-
c. 50 mm bore.
350
-
-
d. 40 mm bore.
350
-
-
e. 25 mm bore.
600
-
-
f. 20 mm bore.
750
-
-
g. 15 mm bore.
365
-
-
S & F GI tubing medium grade with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc Laid in trenches for following size of pipes complete all as specified and as directed :-
a. 100 mm bore.
30
-
-
b. 80 mm bore.
80
-
-
c. 50 mm bore.
250
-
-
d. 40 mm bore.
200
-
-
e. 25 mm bore.
300
-
-
f. 20 mm bore.
350
-
-
g. 15 mm bore.
150
-
-
S & F GI tubing medium grade with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc fixed complete to walls and ceiling or laid in floors for following size of pipes complete all as specified and as directed :-
a. 50 mm bore.
100
-
-
b. 40 mm bore.
150
-
-
c. 25 mm bore.
300
-
-
d. 20 mm bore.
400
-
-
e. 15 mm bore.
215
-
-
S&F in replacement stainless steel ball valve with locking handle complete of following size :-
a. 15 mm dia.
25
-
-
b. 20 mm dia.
60
-
-
c. 25 mm bore.
50
-
-
d. 40 mm bore.
35
-
-
e. 50 mm dia.
20
-
-
S&F in replacement sluice valve class PN-I heavy duty with flanged ends having high stainless steel spindle , cast iron wheel , with shut down and open direction & marked on wheel . (IS-14846-2000) and fixing up complete by providing rubber insertion sheet,nut, bolt, washer etc complete of following sizes:-
(a) For 100 mm dia CI sluice valves.
3
-
-
(b) For 150mm dia CI sluice valves.
4
-
-
(c) For 200mm dia CI sluice valves.
2
-
-
S&F in repairs Non return butterfly valves of size 150mm dia complete all as specified and as directed.
2
-
-
M&L for cutting /breaking of cement concrete path or bituminous road of any thickness with or without reinforcement for taking up/down of GI/CI pipes and connection and making good to surface by PCC (1:2:4) type B1 (Using 20 mm graded stone aggregates) complete all as specified as directed.
15
-
-