Military Engineer Services Tender
... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Feb 2025
Closing Date14 Mar 2025
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_698930_1Tender No
GE I R AND D GNR TOKE3 62 OF 2024 2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Material and labour for cutting of bituminous road / floor for laying of pipe / cables 45 CM wide and not exceeding 1.5 meter deep including refilling / with material and, watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified and directed by Engr-in-Charge.
50
-
-
... More
Supply & Laying 50 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement & directed by EIC.
300
-
-
... More
Supply & Laying 75 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement & directed by EIC.
100
-
-
... More
Supply & Laying 120 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement & directed by EIC.
100
-
-
... More
M & L for GI pipe light grade in repair for road crossing / on wall / on pole for cable protection of following size:-
a) 50 mm dia
30
-
-
... More
b) 80 mm dia
30
-
-
... More
c) 100 mm dia
30
-
-
... More
M & L to find out fault in LT line bring/call fault finding machine equipment and find out fault in any size of LT UG Cable including disconnecting and connecting of cable from both side panels/poles and necessary excavation in any type of strata to reach upto cable and making space for cable joint all as specified and directed.
Note:- (i) Cable required at site same size of faulty cable if required for jointing purpose will be paid in relevant item. (ii) Jointing material will be paid in relevant Item.
10
-
-
... More
M & L to find out fault in HT line bring/call fault finding machine equipment and find out fault in any size HT UG Cable including disconnecting and connecting of cable from both side panels/poles and necessary excavation in any type of strata to reach upto cable and making space for cable joint all as specified and directed.
Note:- (i) Cable required at site same size of faulty cable if required for jointing purpose will be paid in relevant item. (ii) Jointing material will be paid in relevant Item.
5
-
-
... More
Supply and jointing straight through joint, 22000 volts grade heat shrinkable type suitable for 3 core 95 Sqmm to 120 Sqmm, HT, XLPE cable and testing after jointing all as specified and directed by Engr-in-charge.
5
-
-
... More
Supply and fix in repair straight through cable jointing kit 22 KV earthed grade heat shrinkable joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm all as specified and as directed.
4
-
-
... More
Material and labour for dismantling old cable end termination and supply and jointing new Cable end termination heat shrinkable outdoor type suitable for 22KV, 95 Sqmm XLPE, 3 Core power cable with aluminium conductor all as specified and directed.
5
-
-
... More
Material and labour for dismantling old cable end termination and supply and fixing new Cable end termination heat shrinkable outdoor type suitable for 22KV, 120 Sqmm to 185 sqmm, XLPE, 3 Core power cable with aluminium conductor all as specified and directed.
4
-
-
... More
M & L for cable jointing kit for 22 KV earthed graded cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm to 185 sqmm all as specified and directed.
4
-
-
... More
Taking down the existing defective HT UG cable of size 95 sq mm 3 core upto 185 sqmm 3 core in trenches / pipes / pole for attending the repair,jointing materials, refixing / relaying back in trenches fixed on poles complete all as specified and directed. Note-: (i) Excavation and earth work will be measured and paid seperately under relevant item. (ii) Old U/S cable shall be the property of contractor and will be measured in Sch of credit.
90
-
-
... More
Taking down the existing defective LT UG cable of following size in trenches / pipes / pole for fault finding /attending the repair and repair the same all as specified and directed .
(a) 6 sq mm 2/3/3.5/4 core upto 50 sqmm 3/3.5/4 core.
180
-
-
... More
(b) 95 sq mm x 3.5 core upto 300 x 3.5 core sqmm.
Note for item No 17.00 & 17.01(b) above : (i) Cost of excavation & earth work shall deemed to be included in quoted rate. (ii) If the existing cable become faulty and can not be useful, then cable / joint kit shall be provided by contractor as supply and fix under relevent item. Retrived cable shall be handed over to contractor as per schedule of credit.
150
-
-
... More
Supply & fix heat shrinkable jointing kit for 1.1 KV grade cable for straight through joint/ end joint kit complete with jointing material and accessories suitable for 2/3.5/4 core XLPE / PVC armoured AIuminium Conductor cable of following size all as specified and directed .
(a) 16 sqmm to 50 sqmm
8
-
-
... More
(b) 70 sqmm to 120 sq mm
8
-
-
... More
(b) 150 sqmm to 185 sqmm
4
-
-
... More
(c) 240 sqmm to 300 sq mm
4
-
-
... More
Supply and lay LT XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade of following cross-sectional area including cable lugs, jointing materials etc., laid in trenches fixed on poles or laid through GI pipes including taking down old unserviceable cable all as specified and directed .
Note-: (i) Excavation and earth work shall be measured and paid seperately under relevant item. (ii) Old U/S cable shall be the property of contractor and will be measured as per Sch of credit.
(a) 2 core 6 sq. mm
180
-
-
... More
(b) 2 core 10 sq. mm
150
-
-
... More
(c) 2 core 16 sq. mm
200
-
-
... More
(d) 4 core 16 sq. mm
150
-
-
... More
(e) 3.5 Core sec. area 25 sq. mm
150
-
-
... More
(f) 3.5 Core sec. area 35 sq. mm
200
-
-
... More
(g) 3.5 Core sec. area 50 sq. mm
150
-
-
... More
(h) 3.5 Core sec. area 70 sq. mm
150
-
-
... More
(j) 3.5 Core sec. area 185 sq. mm
50
-
-
... More
(k) 3.5 Core sec area 240 sq. mm
50
-
-
... More
(l) 3.5 Core sec. area 300 sq. mm
50
-
-
... More
Strengthening and Restringing of HT/LT over head ACSR conductor of any size in overhead lines inlcuding removing and replacement of binding wire from insulators and triming the branches on both / above side of the line before,stringing and rebinding of insulators after stringing complete all as specified and as directed by Engineer - in - Charge.
100
-
-
... More
Dismantling of old jumper, including supply and fixing new jumper connection at cut point on HT / LT over head line with suitable size of ASCR conductor 6 / 1 x 3.00 mm (ferrule) PG Clamps, lugs, alkatriene sleaves complete of required length not exceeding 3 mtr including testing on completion complete all as specified and as directed by Engineer - in - Charge.
15
-
-
... More
M&L for ACSR conductor on existing poles including dismantling of old unsv ACSR conductor all as specified & directed.
0.5
-
-
... More
Servicing the 22 KV GOD by cleaning the contact, disc/pin insulator with CTC & applying the petroleum jelly at the contact point/down rod links for smooth operation including replacing the rusted/corroded bolts & nuts and defective insulator of GOD as required at site and as directed.
Note :- Insulator shall be measured and paid seperately under relavant items.
4
-
-
... More
a) Male / Moving contact ( set of 3 Nos )
4
-
-
... More
b) Female / Fixed contact ( set of 3 Nos )
4
-
-
... More
c) Copper tinned strip ( set of 3 Nos )
4
-
-
... More
Material and labour for dismantling old U/S AB switch and Supply, installation. connecting electrically & commissioning switch air break, gang operated, tripple pole mounted on insulators 15 Nos with drop out fuse and steel frame with operating mechanism in working from ground level, including jumper connection with ACSR conductor alongwith PVC pipe covering with colour code between main supply and GOD complete all as specified and directed for current rating upto 200 amps and working voltage 22000 volts all as required at site or directed by Engr-in-charge.
1
-
-
... More
Cutting / trimming of Tree branches which are touching to HT / LT over head lines and clearing the same up to 4 meter radius for span length not exceeding 45 to 55 meter complete all as specified and as directed by Engineer - in - Charge. Note: Each span of 45-55 Mtrs will be considered as one length of span for payment purpose.
150
-
-
... More
M & L for painting of steel tubular LT pole up to 9 mtr long with two coats of aluminium paint incl cross arms (for single pole), clamps etc complete including marking of pole No with black paint with all arrangement for ladder etc all as specified and directed.
250
-
-
... More
M & L for line separator suitable for LT line four conductor feeder all as specified.
30
-
-
... More
M & L for line separator suitable for LT line three conductor in horizontal /vertical feeder all as specified.
30
-
-
... More
Isolate/de-energize the supply to the HT/LT Panel Board of capacity ranging from 200 Amps to 2000 Amps, opening the doors/covers of the cubicle enclosure for carrying out the servicing/ maintenance/ repairs of the Panel Board, switch gear, metering etc and re-fixing the same in place after repairs including testing and commissioning of the panel board comprising of the following:-
a) Cleaning the inside switch gear chambers for removing dust, carbon and rusted surfaces including cleaning with blower and apply insulating varnish.
b) Check the condition of the DMC/SMC support insulators including cleaning applying Dr beck red for better IR values and replacement of insulators if required. c) Tightening up of all bus bar connections, cable connections, replace bolt, nuts wherever required.
Note : Contractor has to inspect the site before quoting. Any modifications/frame work and renewal is deemed to be included in the quoted rates. Spares will be measured and paid under relevant items of schedule
10
-
-
... More
S&F in repair mild steel hinges suitable for LT panel board shutters including welding, riveting complete all as specified and as directed.
6
-
-
... More
Disconnecting and taking out old existing worn out control wiring connections including cable lugs of LT panel board of 4 wire system and supply and connect with new cable PVC insulated, stranded copper conductor 2.5 sqmm including with new copper lugs and nuts, bolts, washers complete all as specified and directed.
10
-
-
... More
Disconnecting and taking out old existing worn out cable lugs, nuts, bolts, washers etc from LT panel board of 4 wire system (incomming and outgoing) and supply and connect with new aluminium lugs all sizes as per site requirement and nuts, bolts, washers etc complete all as specified and directed.
13
-
-
... More
Material and labour for dismantling of old steel tubular pole and suppy, errecting in truly vertical position steel tubular swaged pole 11 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 55, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative white & black strips of 30 cm width upto 1.5 mtr above ground level all as required at site and as directed.
1
-
-
... More
Material and labour for dismantling of old steel tubular pole and suppy, errecting in truly vertical position steel tubular swaged pole 9.0 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative white & black strips of 30 cm width upto 1.5 mtr above ground level all as required at site and as directed.
4
-
-
... More
Surface excavation not exceding 30 cm deep in hard dense soil and averaging 15 cm deep and getting out green vegetation, roots, bushes, etc surrounding of 2 / 4 / 6 pole structure / substations / RMU all as directed by Engr-in- charge.
250
-
-
... More
M&L for PCC 1:4:8 Type D2 (using 40 mm graded stone aggregate) as in foundation including necessary form work if required and finishing the exposed surface of concrete even and smooth complete all as specified and directed.
4
-
-
... More
M & L for PCC 1:3:6 type, type C-2 (using 40 mm graded stone aggregate) as in foundation of stay, for making good the disturbed portion of road/floor/platform etc including necessary form work if required complete all as specified and directed.
1
-
-
... More
M&L for providing PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) for coping of pole including necessary form work if required complete all as specified and directed.
1
-
-
... More
S& F in replacement of MCCB 3 Pole 63 Amps 16 KA Thermal magnetic adjustable type with both side spreader links all as specified and directed.
4
-
-
... More
S& F in replacement of MCCB 3 Pole 100 Amps 16 KA Thermal magnetic adjustable type with both side spreader links all as specified and directed.
4
-
-
... More
S& F in replacement of MCCB 3 Pole 160 Amps 25 KA Thermal magnetic adjustable type with both side spreader links all as specified and directed.
2
-
-
... More
S& F in replacement of MCCB 4 Pole 200 Amps 25 KA Thermal magnetic adjustable type with both side spreader links all as specified and directed.
2
-
-
... More
S& F in replacement of MCCB 4 Pole 250 Amps 25 KA Thermal magnetic adjustable type with both side spreader links all as specified and directed.
2
-
-
... More
S& F in replacement of MCCB 4 Pole 400 Amps 36 KA Thermal magnetic adjustable type with both side spreader links all as specified and directed.
2
-
-
... More
S& F in replacement of MCCB 4 Pole 630 Amps 36 KA Thermal magnetic adjustable type with both side spreader links all as specified and directed.
2
-
-
... More
S& F in replacement of MCCB 4 Pole 800Amps 50 KA Thermal magnetic adjustable type with both side spreader links all as specified and directed.
1
-
-
... More
S & F in replacement of ACB type manual fixed with microprocessor based LSIG & tempreture rise protection consisting of digital display with battery backup 3 ph ,4 pole , 415 Volts, 630 Ampr 50KA in existing panel & connecting to incoming & outgoing with suitable rating of Aluminium/Copper busbar properly testing of ACB all as specified and directed . Make: Legrand/ABB/Siemens / L&T as approved.
1
-
-
... More
S & F in replacement of ACB type manual fixed with microprocessor based LSIG & temprature rise protection consisting of digital display with battery backup 3 ph ,4 pole , 415 Volts, 800 Ampr 50KA in existing panel & connecting to incoming & outgoing with suitable rating of Aluminium/Copper busbar properly testing of ACB all as specified and directed .
Make: Legrand/ABB/Siemens / L&T as approved.
1
-
-
... More
S & F in replacement of power contactor 4 pole , 415 Volts, 630 Ampr AC1 with integrated auxiliary contacts and coil voltage 200-240V AC/DC in existing panel & connecting to incoming & outgoing with suitable rating of Aluminium/Copper busbar properly all as specified and directed .
1
-
-
... More
S & F in replacement of power contactor 4 pole , 415 Volts, 800 Ampr AC1 with integrated auxiliary contacts and coil voltage 100-240V AC/DC in existing panel & connecting to incoming & outgoing with suitable rating of Aluminium/Copper busbar properly all as specified and directed .
1
-
-
... More
S&F in replacement of 3 phase digital multi function meter with suitable accessories and fixing arrangements all as directed.
5
-
-
... More
S&F in replacement of selector switch suitable for 415 volts all as specified and directed.
6
-
-
... More
S&F in replacment of voltmeter/Ammeter of range 0 to 500 Volts as specified and directed.
10
-
-
... More
S&F in replacament of LED type phase indicator to be fitted on panel ( R,Y, B as per site requirement)
18
-
-
... More
M&L for dismentling and disconnecting the ACB rating 800/630 amps of any approved make by carrying out repairs/ servicing, checking and renewing the defective shunt trip coil & UV trip 415 volts AC, checking and rectifying the defective CTs and rectifying the mechanism operation including spring charging system, reinstalling the same in the panel and providing necessary line and connections all as directed by Engineer-in-charge
2
-
-
... More
Material and labour for dismantling of old danger notice plate and supply and fixing danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts & nuts of approved size of 20 x 15 cm with font written "22 KV" as specified and directed.
25
-
-
... More
Material and labour for dismantling of old danger notice plate and supply and fixing danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts & nuts of approved size of 20 x 15 cm with font written "440 Volts" as specified and directed.
25
-
-
... More
M & L for Scraping of old paint from 2 pole structure without removing accessories and preparation of surfaces for repainting, painting of 2 pole structure with two coats of aluminium paint incl channels, DO fuse parts, clamps etc complete including marking of pole numbers (with yellow background and black colour font) with all arrangement for ladder and painting of bottom portion of the pole upto 1.0 m from top of the copping with one coat of synthetic enamel red paint over a coat of red oxide primer etc all as specified and directed.
4
-
-
... More
M & L for Scraping of old paint from 4 pole structure without removing accessories and preparation of surfaces for repainting, painting of 4 pole structure with two coats of aluminium paint incl channels, DO fuse parts, clamps etc complete including marking of pole numbers (with yellow background and black colour font) with all arrangement for ladder and painting of bottom portion of the pole upto 1.0 m from top of the copping with one coat of synthetic enamel red paint over a coat of red oxide primer etc all as specified and directed.
4
-
-
... More
Supply & fix HT fuse element 22 KV fibre glass type suitable for folloiwng :- (a) 22 KV 50 Amps
30
-
-
... More
(b) 22 KV 60 Amps
50
-
-
... More
Disconnecting all the electrical connections from H.T.and L.T. side of unserviceable transformer of cap above 160 KVA to 500 KVA i.e. Jumpers/cable from the cable end box or bushings & earthing terminal of the transformers, loading and unloading of transformer with help of crane or other mode and transportation by vehicle from substation to the repairing workshop including reinstallation, commissioning and testing complete all as specified and directed.
3
-
-
... More
Opening the transformer cover along with the conservator by removing the nut bolts then after removing the internal HT & LT connections by taking them out by removing studs, bushings, taking out the core-winding assembly out of the tank removing out burnt HV and LV windings from the core assembly, Draining & decanting of burnt transformer oil and cleaning of sludge deposited in the tank with CTC of transformer having ratio 22/0.433 KV . Rewinding of HV and LV coils with suitable size super enamelled copper wire / strip ( As Existing ) having suitable class insulation material. Heating of core winding assembly in hot chamber for 48 hours and remove all the moisture present in it, removal of leakage of tank if any by welding, refilling transformer oil to tank, after putting the core-winding assembly into the tank, reassembling making the internal H.T. & L.T. connections by fixing the studs, bushings,fitting the top cover by replacing cork sheet gasket along with conservator, testing the transformer in the workshop, all as directed by Engineer-in-charge.for various capacities as under. Note:- Rewinding Material will be measured seperately.
a) upto 160KVA
1
-
-
... More
b) All as per item herein above 160KVA to 500 KVA
1
-
-
... More
Supply and fix super enamelled copper winding wire / strip of any size for H.T coils of transformers complete all as specified and directed.
90
-
-
... More
Supply and fix copper winding wire/ strip of any size for L.T. coils of transformers including providing insulation all as required complete all as specified and directed.
80
-
-
... More
Reconditioning of LT coil of copper wound transformer by turning the old paper insulations, straightening the entire LT Strip providing new paper insulations of superior quality and making coil of suitable design as original all as specified and directed by Engr-in-Charge.
250
-
-
... More
Supply & fix HT Bushing (as per sample) all as directed.
6
-
-
... More
Supply & fix LT Bushing (as per sample) all as directed.
6
-
-
... More
Supply & fix brass stud (for LT433V side) of suitable size complete with one chuck nut, two nuts, washers and rubber seal, all as per sample for outdoor type transformer of the capacity as under:-
a) upto 160 KVA
3
-
-
... More
b) All as per item herein above but for 160KVA upto 250KVA complete all as specified and directed.
3
-
-
... More
c) All as per item herein above but for 250KVA upto 500KVA complete all as specified and directed.
3
-
-
... More
Supply & fix brass stud (for HT 22KV side) of suitable size complete with one chuck nut, two nuts, washers and rubber seal, all as per sample for outdoor type transformer of the capacity as under:-
a) upto 160KVA
3
-
-
... More
b) All as per item herein above but for 160KVA upto 250KVA
3
-
-
... More
c) All as per item herein above but for 250KVA upto 500KVA
3
-
-
... More
Scrubbing of old rusted paint from transformer and preparation of surfaces for fresh painting, by means of spray painting with two coats of synthetic enamel paint of approved colour of transformer up capacity 100 KVA to 500 KVA and writing SM No/MES No of the transformer etc complete all as specified and as directed.
8
-
-
... More
M&L for dehydration of transformer oil with mobile transformer oil filtration plant at site with all accessories connected to transformer and carrying out filtration of oil for desired dielectric strength i.e. not less than 60 KV at 2.5mm gap all as directed.
Note :- 1. Test certificates shall be submitted before and after filtration for dielectric strength on the proper format.
2. Power supply arrangement for the dehydration machine will be provided by contractor.
800
-
-
... More
M & L for replacement of breather assembly of transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for pipe entry of 15/20/25mm dia as per the site requirement, complete all as specified and as directed by Engineer-in-Charge.
6
-
-
... More
Supply and Filling/ topping up new transfermer oil of approved make conforming to IS- 335 / 1983 including testing of IR value of the oil not less than 60 KV, complete all as specifaied and as directed by Engineer - in - charge.
800
-
-
... More
M&L for taking down transformer oil level indicator assembly of transformer upto 500 KVA capacity from position for making visibility of oil level by lowering oil level in conservator including cleaning thoroughly, painting, changing of gaskets and acrylic sheet, fixing back in position refilling the removed oil all as directed.
6
-
-
... More
M & L for repair to earth chamber by providing plastering to existing earth chamber including provision of new earth chamber cover of specified size and marking the earth pit number, complete all as specified and as directed by Engineer-in-charge.
5
-
-
... More
M&L in replacement of earth pit indicator board made out of MS sheet 6mm thick of size 25cm x 15cm fixed on MS flat of size 40 x 6mm x 1.2mtr (long) by means of nut, bolt/ welding duly painted with two coats of synthetic enamel paint over a coat of red oxide paint of approved colour including writing the letters of size not exceeding 60mm all as directed by Engineer - in - charge. The indicator should indicate the following :- (i) Earth Pit No. (ii) Earth result in Ohms (iii) Date of testing
Note :- (i) Cost of excavation of earth in any type of soil/ rock for erection of earth pit indicator board removal (upto the 50 Mtrs from starting point) and returning filling in of soil/ rock is deemed to be included in the quoted rate.
20
-
-
... More
M&L in repairs of GI funnels with wire mesh for earthing complete all as specified and as directed by Engineer-in-charge.
25
-
-
... More
M&L for earth testing, identifying the earthings in system and recording the results on indicator board and maintain the register for the same all as directed by Engr-in-charge.
Note :- (i) Cost of labour and tools required for testing is deemed to be included in quoted rates.
50
-
-
... More
M&L for earthing with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground earth pit not less than 2.25M deep below ground level with top edge of the plate not less than 1.5M below normal ground level connected to galvanised strip 32 x 6mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point including excavation/ earth work in any strata removal of surplus earth, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with 40mm dia light grade GI protection pipe and 20mm dia light grade GI pipe for watering all as specified and directed by Engr-in-charge.
Note : Earth lead strip upto 7.5m is included in quoted rate.
5
-
-
... More
M&L for earthing with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground earth pit not less than 2.25M deep below ground level with top edge of the plate not less than 1.5M below normal ground level connected to GI Earth wire 4 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point including excavation/ earth work in any strata removal of surplus earth, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with 40mm dia light grade GI protection pipe and 20mm dia light grade GI pipe for watering all as specified and directed by Engr-in-charge.
Note : Earth lead wire upto 7.5m is included in quoted rate.
5
-
-
... More
M&L for earthing with copper plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25M deep below ground level with top edge of the plate not less than 1.5M below normal ground level connected to copper strip 20 x 3 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earthing test point including excavation/ earth work in any strata removal of surplus earth, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with 40mm dia light grade GI protection pipe and 20mm dia light grade GI pipe for watering all as specified and directed by Engr-in-charge.
Note : Earth lead strip upto 7.5m is included in quoted rate.
5
-
-
... More
M&L for hard core of broken stone or boulders of gauge n. exc. 40 mm, deposited, spread and leveled in layers n. exc. 200 cm thick, watered and rammed to a true surface complete all as specified and directed.
12
-
-
... More
S&F in replacement of timer switch 16 Amps, 230 Volts, 24 hrs dial type for operation with by pass operation complete all as specified and directed.
4
-
-
... More
S&F in replacement of triple pole power contactor suitable for 40 Amps, with coil voltage 230 Volts complete all as specified and directed.
4
-
-
... More
Supply and fix outdoor type FRP junction box light weight suitable for pole mounting including flat iron clamp duly painted with two coats of aluminium paint over a coat of red oxide primer and GI nut, bolts, washers and necessary connector for loop in loop out cable connection and suitable size glands, of size 200x140x95 mm all as directed by EIC.
20
-
-
... More
Supply and fix in replacement of 3 core x 1.5 sq mm PVC Circular copper cable for connection of street light fitting, Security light fitting, post top lantern and garden light fitting and including all fixing arrengenment with proper fixing all as directed by Engr in charge.
100
-
-
... More
Dismantling and taking down existing Street light / Gate light / Garden Light, any type / capacity and carrying out repairs and replacement of drivers and refixing on bldgs/poles /wall.
50
-
-
... More
S & Fix LED Street light fitting 90 Watts High performance IP 66 LED street light luminaires with complete acessories all as specified and directed by Engr In charge.
40
-
-
... More
S & Fix LED Street light fitting 60 Watts High performance IP 66 LED street light luminaires with complete acessories all as specified and directed by Engr In charge.
35
-
-
... More
S & Fix LED Street light fitting 45 Watts High performance IP 66 LED street light luminaires with complete acessories all as specified and directed by Engr In charge.
15
-
-
... More
Supply & fix of 30 / 35 W LED post top lantern for 360 degree designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform illumination all as directed and specified.
10
-
-
... More
Supply & fix of 40 / 45 W LED post top lantern for 360 degree designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform illumination all as directed and specified.
5
-
-
... More
M & L for replacement of unserviceable MS clamp with new clamp as per sample/as per site requirement made out of MS flat iron 25 x 5mm including fixing nuts bolts, washers etc and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed
10
-
-
... More
Supply and fix electronic driver for LED street light fitting as per sample/existing fitting specifications complete with all accessories as suitable for street light fitting of size 90 Watt all as directed.
Note- Quoted rate include replacement of driver and testing and making fitting serviceable and upto entire satisfaction of JE/Engr-in-Charge.
30
-
-
... More
Supply and fix electronic driver for LED street light fitting as per sample/existing fitting specifications complete with all accessories as suitalable for street light fitting of size 60 Watt complete all as specified and directed.
Note- Quoted rate include replacement of driver and testing and making fitting serviceable and upto entire satisfaction of JE/Engr-in-Charge.
25
-
-
... More
Supply and fix electronic driver for LED street light fitting as per sample/existing fitting specifications complete with all accessories as suitalable for street light fitting of size 30 to 45 Watt complete all as specified and directed.
Note- Quoted rate include replacement of driver and testing and making fitting serviceable and upto entire satisfaction of JE/Engr-in-Charge.
15
-
-
... More
M&L for PCC 1:2:4 type B2 (using 40 mm granded stone stone aggregate) in foundations, filling and mass concrete complete including removing of all the connections from LT and HT side, shifting the transformer using by the crane and connecting the LT and HT cable to the transformer and shifting the transformer on the new platform all as specified and directed by Engr-in-Charge.
2
-
-
... More
Dismantling and taking down existing any type unserviceable parts and complete overhauling of High galvanised mast light suitable for 6 to 9 lantern symmetrically fitted along with their control gear having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 gauge and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light lightning arrester spike including greasing of motor / pulley parts all as directed. Note : Spares shall be measured and paid separately as supply only under relevant item here in below :-
4
-
-
... More
Supply only spares for item of High mast
(a) Rope SWR 6mm .
30
-
-
... More
(b) Gear motor
4
-
-
... More
(c) 5 core cable
35
-
-
... More
(d) Suitable LED Fitting 250 watt IP 66.
6
-
-
... More
M& L for VCB Cleaning, Greasing mechanism, Old greasing cleaning, Checked Electrical Motor, Checked & tight control connection, Checked Charging Mechanism, Greasing Moving part and mechanism, Checked Electrical Motor, Checked HT Cable Connection, Checked Boots, Earth Switch ON OFF Operation, Checked shunt coil, Checked Functions of relay Schneider Electric Make Relay Testing:
Overload Current, Short circuit Ground Fault, CT R Phase, Y Phase CT, B Phase CT, Control Wiring Checking
VCB Panel Heater Installation (Per Panel 2 heaters) Control Wiring , MCB serviceable and upto entire satisfaction of JE/Engr-in-Charge.
Note : Spares to the extent required shall be measured & paid as 'supply only'.
5
-
-
... More
Supply only spares for VCB
(a) HT Tape
4
-
-
... More
(b) HT Boot kit suitable for HT VCB panel complete all as specified and directed.
4
-
-
... More
(c) Relay suitable for HT VCB panel complete all as specified and directed. make schneider
4
-
-
... More
(d) Tripping coil
6
-
-
... More
(e) CT suitable for HT VCB panel complete all as specified and directed.
4
-
-
... More
(f) Heater suitable for HT VCB panel complete all as specified and directed.
10
-
-
... More
(g) Relay batteries
5
-
-
... More
(h) Power Pact 24 V DC
1
-
-
... More
Material and Labour for removing the RMU / VCB panel from its existing place including dismantling the HT cable, transporting to the company for testing of any leakage in RMU / VCB panels, arresting the leakage, filling of Gas to the desired volume for the HT Breaker and servicing the RMU / VCB panel and reinstalling the same at the existing place, joining of HT cable to the panel all as specified and directed by Engr-in-Charge.
Note : The above rate includes the arrangement for removing, transporting, servicing, testing and reinstalling of RMU / VCB Panel all as directed.
1
-
-
... More
Supply & Laying synthetic rubber insulated mat 3mm thick for voltage up to 1.1 KV for electric shock safety of size 2X1m. complete all as specified and as directed by Engineer - in - Charge
4
-
-
... More
Supply & Laying synthetic rubber insulated mat 3mm thick for voltage up to 22 KV for electric shock safety of size 2X1m. complete all as specified and as directed by Engineer - in - Charge
5
-
-
... More
Material and labour for dismantling of old steel tubular pole and suppy, errecting in truly vertical position steel tubular swaged pole 8.5 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 22, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative white & black strips of 30 cm width upto 1.5 mtr above ground level all as required at site & all as directed.
3
-
-
... More
Supply & fix cylindrical capacitors for following sizes as per existing capacitor bank panel including all fixing arrengenment with proper fixing all as directed by Engr in charge. Make:Havells & Epcos.
(a) 15 KVAR
2
-
-
... More
(b) 10 KVAR
2
-
-
... More
(c ) 7.5 KVAR
3
-
-
... More
(d) 5 KVAR
3
-
-
... More
Supply & fix box type power capacitors of size 3 KVAR for improvement of power factor in the panels including all fixing arrangement with proper fixing all as directed by Engr in charge.
10
-
-
... More
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm to 300 mm dia all as directed.
15
-
-
... More
Supply and fixing of Fire Extinguisher CO2 type fire extinguisher of capacity 4.5 kg made from brand new seamless cylinder fitted with discharge hose and horn and squeeze grip type valve with initial charge all as directed.
5
-
-
... More
Supply and fixing of fire beater made out of mild steel alongwith 6 feet long bamboo handle for sub stations all as specified and directed by Engr-in-Charge.
5
-
-
... More
Supply and fixing of fire hook made out of mild steel alongwith 6 feet long bamboo handle for sub stations all as specified and directed by Engr-in-Charge.
5
-
-
... More
Supply and fixing of Iron Galvanised Fire Bucket of size 9 Ltrs all as specified and directed by Engr-in-Charge.
5
-
-
... More
Material and labour for dismantling old lightening arrestor and Supply and fix lightening arrester, complete with all fittings, transmission classes, discharge capacity 10 Kilo amps suitable for 22 KV out door type complete all as specified and directed including taking down the existing LA.
6
-
-
... More
Supply and fixing of cable route marker for LT Cable made out of CI, 8 inch of length and 4 inch dia painted with yellow colour including pcc work complete all as specified and directed by Engr-in-charge.
10
-
-
... More
Supply and fixing of cable route marker for HT Cable made out of CI, 8 inch of length and 4 inch dia painted with yellow colour including pcc complete all as specified and directed by Engr-in-charge.
10
-
-
... More
Supply and fix of aluminium lugs of size 16 sqmm to 25 sqmm all as directed.
15
-
-
... More
Supply and fix of aluminium lugs of size 35 sqmm to 50 sqmm all as directed.
15
-
-
... More
Supply and fix of aluminium lugs of size 70 sqmm to 95 sqmm all as directed.
15
-
-
... More
Supply and fix of aluminium lugs of size 120 sqmm to 185 sqmm all as directed.
15
-
-
... More
Supply and fix of aluminium lugs of size 240 sqmm to 300 sqmm all as directed.
15
-
-
... More
Supply, install, connect & testing main switch of cap 200 Amps, 415 Volts, 3 phase and neutral in cubical outdoor type factory made sinle door, powder coated feeder pillar box of size 400mm x 400mm x 200mm complete weather proof and verminproof conforming to IP-54 made out of 3.2 mm thick CRCA sheet. It should be mounted on 40 x 40 x 6mm angle frame with a clearance of at least 0.45 mtrs above GL and 0.30 mtrs below ground including required PCC for foundation and coping complete all as specified and directed.
1
-
-
... More
Material and labour for scrapping / removing of rust on the panel boards preparation of surfaces for fresh painting, cleaning inside the panel boards with the vacuum or blower and painting by means of spray paint with two coats of synthetic enamel paint of approved colour all as specified and directed by Engr-in-Charge.
5
-
-
... More
Supply and fixing of GI bend for fixing of street light fitting on the poles / buildings all as specified and directed by Engr-in-Charge.
15
-
-
... More
Dismantiling of ACSR conduyctor alongwith the cross arms and connected accessories and old unsv ACSR conductor shall be the property of contractor and will be measured in Sch of credit complete all as specified and directed.
0.5
-
-
... More
Supply and install of rectangular Acrylic and steel sign boards with LED tube lights inside for all sub stations, made out of steel and acrylic sheet on front with blue colour and white font of size 5' x 3' x1' (LxHxW) alongwith 50x50x5 mm angle iron of 4 feet length above ground level and 2 feet below ground level on sides of the sign boards including syntax box with MCB and PCC work for erecting of the sign board, all as specified and directed by Engr-in-Charge.
Note : (i) The content for the sub station boards will be provided by MES.
(ii) The rates includes the connection of the LED board with cable to the nearest street light supply, welding and masnory works.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%