Military Engineer Services Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Feb 2025
Closing Date5 Mar 2025
Tender Amount₹ 14,97,95,00,00,000 
Notes
Download

AI Insights

Class Of Bidder
... View More
The class eligibility requirement to bid or participate in this tender is Class 'B' and above.
Technical Capacity
... View More
The required prior work experience for the bidder includes satisfactorily completion of requisite value works with Central/State Government/ Central/ State PSUs/AWHO/ AFNHB/ CGEWHO/ DGMAP, and the bidder should meet the enlistment criteria of Class ‘B’ and above and category ‘b (i)’. However, specific details on the required prior work experience, value, and percentage of similar works completed are not mentioned, including specific values like amount and percentage.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing surplus soil to a distance outside MD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr in Charge.

10

-

-

... More
Supply ,install , testing and commissioning LT panel in replacement, indoor type Aluminium bus bar with colour coded heat shrinkable sleeves, IP 43 Protection class, factory fabricated, cubical panel,provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,1 ft long grouted on PCC foundation of height not less than 40 cm from the ground level , grouting properly , free standing type, made out of 2mm thick CRCA sheet with locking arrangement, both sides openable, having cable gallery of suitable size for easy connection of cables, dust vermin proof suitable for 3 phase 4 wire 415 volt 50Hz AC including Digital multi display meter with selector switch,phase indicator lamp(RYB), suitable size copper conductor control wiring and power coating, connecting the cable with necessary cable glands, lugs etc for all incoming & outgoing cables, proper arrangement for ventilation accomodating the following items and space as per site complete all as specified and directed by Engineer-in-Charge. Note :- 1. LT Panel shall be fabricated from CPRI approved Manufacturer and manufacture as per site space measured by contractor. 2. Comprising of the following items :- (a) MCCB 630A, rated for 415Volt, 4 pole, 3 Phase, rupturing capacity of 36KA, Thermal-Magnetic type MCCB, Qty-01 No. (incoming), the service short circuit breaking capacity (Ics) shall be equal to ultimate breaking capacity (Icu) i.e. Ics =100% Icu. (Thermal adjustment and magnetic adjustment setting) (b) MCCB 250A, Rated for 415Volt, 4 pole, 3 Phase rupturing capacity of 36KA, Thermal-Magnetic type MCCB, Qty-04 No. (Outgoing) the service short circuit breaking capacity (Ics) shall be equal to ultimate breaking capacity (Icu) i.e. Ics =100% Icu. Fixed Thermal and magnetic setting (c) MCCB 160 A, Rated for 415Volt, 4 pole, 3 Phase, rupturing capacity of 25kA, Thermal-Magnetic type Qty-02 No (Outgoing) (d) Indicating lamp - 02 sets (e) Digital volt / ammeter -02 Nos with selector switch (f) CT coil 400/5A - 01

1

-

-

... More
Supply, fix, install, testing and commissioning of feeder pillar box ,out door type cubical shape,three phase, 4 wire, copper bus bar CRCA sheet ,3 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,1 ft long grouted on PCC foundation of height not less than 40 cm from the ground level , grouting properly ,and of suitable size to accommodate the items mentioned below and having separate compartment /chambers for cable gallery busbar,switch gear and front side openable , back side fixed l etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc including taking down existing panel. (i) MCCB 4 Pole, 415V, adjustable type, 200 Amps with breaking capacity 36KA -01 No (Incoming) (ii) MCCB 4 pole 415V fixed type, 63 to 100 Amps with breaking capacity 16KA. -03 Nos (iii) MCB Isolator 40 Amps- 06 Nos (outgoing) (iv) Voltmeter,digital type 0- 400 volt,with selector switch -01 set (v) Phase indicating lamps LED type ( red , yellow, blue) -01 set (vi)Ammeter Digital type 0-100Amps, with selector switch and CT'-1set .

4

-

-

... More
Supply, fix, install, testing and commissioning of feeder pillar box ,indoor type cubical shape,three phase, 4 wire, copper bus bar rating 400 amps for phases and 200 amps for neutral made out of CRCA sheet ,2 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,1 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accommodate the items mentioned below and having separate compartment /chambers for cable gallery busbar,switch gear and front side double door openable , back side fixed wall etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc .(i) MCCB 4 Pole, 415V, adjustable type, 200 Amps with breaking capacity 36KA -01 No (Incoming) (ii) MCCB 3 pole 415V fixed type, 63 to 100 Amps with breaking capacity 16KA. - 04 Nos (outgoing) (iii) MCB Isolator 40 Amps- 02 Nos (outgoing) (iv) Voltmeter,digital type 0- 400 volt,with selector switch -01 set (v) Phase indicating lamps LED type ( red , yellow, blue) -01 set (vi)Ammeter Digital type 0-100Amps, with selector switch and CT'-1set .

1

-

-

... More
Supply & install, testing and commissioning of indoor type AMFpanel for automatic operation of the DG set, comprising of main and DG contctors , auto unit timers , relay , metering , fuses , incomming MCCB 160 Amps 04 pole, cubicle panel board, 415 V, 3 phase, 4 wire, aluminium bus bar of rating 300 Amps, contractor 200Amps and made out of 2.0 mm thick thick CRCA sheet , factory fabricated , CPRI approved , powder coated(seven tank processed) with approved shade ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50 x 50 x 6 mm thick angle iron , grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery, cable glands, cable lugs , bus bar, MCCB fixed vertically with bus bar and panel both side (front and back) openable etc all as specified and comprising of including necessary PCC work, cable connections to the MCCBs digital multifunction meter and cable lugs etc complete all as specified and directed by Engineer In Charge.

2

-

-

... More
Taking out old Unserviceable LT Panal from pump house and Supply, install, testing and commissioning of motor on /off LT Panel CPRI Approved mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type, with front side opening or suitable fixing of all breakers and controls for 415V, 3 phase, made of 2 mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 600 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections Panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmework and PCC foundation including shifting of existing of LT Panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :- (a) Motor star delta starter suitable for UPTO 12.5 HP motor - 02 Nos (b) MCCB 250 Amps, 36 KA FP - 01 Nos (c) (f) MCCB 100 Amps, 36 KA, FP - 04 Nos (d) conrol panel wiring with 2.50 sq mm multistranded, pvc insulated copper conductor cable between voltmeter, Am meter, and their selector switch complete with CTs of ratio 400/5A- 2 Nos,320/5 A- 2 Nos , 250/5 A- 2 Nos ,200/5 A - 2 Nos , 160/5 A - 2 Nos , voltmeter flush pattern type 96 mm square dial -1 nos, Am- meter digital CT operated 96 mm sqare dial flush pattern type -10 Nos, indication lamp for 3 phase and control fuses-3 Nos complete . (e) Aluminium bus bar 400 Amps for phase & 200 Amps for neutral complete with bus bar insulator,nuts & bolts complete. (f) Power panel wiring between bus bar to MCCB of different capacity with PVC insulated multistranded copper cable , 10 Sqmm ,single core ,1100 volts grade of appropriate size complete with copper lugs. (g) Digital Ammeter-03 No, (h) Digital Voltmeter-03 No (j) Phase indicator lamp R,Y & B with slector switch - 03 Set

2

-

-

... More
Supply & fix LED type security search light for 2000 Watt with stand fitting as per AJMERA (marine search light) weather proof cromium plated brass body, wheel house arrangements for both vertical and horizontal direction made out of brass sheet complete with heat resistant toughned glass with hot air scape arrangement with LED lamp provided on security watch tower situted along the perimeter of wall and area all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Supply & install, testing and commissioning of outdoor type cubicle panel board, 415 V, 3 phase, 4 wire, aluminium bus bar of rating 200 Amps, made out of 3 mm thick CRCA sheet , factory fabricated , CPRI approved , powder coated(seven tank processed) with approved shade ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50 x 50 x 6 mm thick angle iron , grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery, cable glands, cable lugs, bus bar, MCCB fixed vertically with bus bar and panel both side (front and back) openable etc all as specified and comprising of following including necessary PCC work, cable connections to the MCCBs digital multifunction meter and cable lugs etc . :- (a) MCCB 4 Pole, 415V, 50Hz adjustable magnitic & thermal type, 100 Amps with breaking capacity 16KA. - 01 No. (Incoming). (b) MCCB 4 Pole, 415V, 50Hz adjustable magnitic & thermal type, 63 Amps with breaking capacity 25KA. -02 (c) Phase indicating lamps LED type ( Red , Yellow, Blue) - 02 set

1

-

-

... More
M&L for PCC 1:3:6 type C 1 using 20 mm graded stone aggregate block masonry with solid block, exc 10 cm in width and setting in mortar complete for coping of pole including necessary from work and fair finish to the exposed surface area without using extra cement complete all as specified and directed by Engineer-in-Charge.

40

-

-

... More
Supply and fix 8 W LED bolard Cone NXG Series with touch of aesthetic innovative design with uniformally with its diffuser at the upper portion acts a beacon of path guidance in a landscape environment with robush IP 65 rating including foundation nut botls including taking down old complete all as specifed and directed by Engr in Charge.

40

-

-

... More
Supply and fixing in repair Steel tubular swaged street light poles complete with pole arms 1.2 m & cast iron base plate ,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 , 8.5 mtr long and painting with two coat of aluminium paint over one coat of primer on exposed surface of pole including taking down old rusted pole complete all as specified and directed by Engineer-in-Charge. (NOTE- Excavation & PCC will be measured and paid separately)

20

-

-

... More
Supply & fix hot dip galvanized anti corroded weather proof octagonal electric poles 6 mtrs long top mounting on foundation complete with base plate and final including PCC foundation as per manufacturer design with 1500 mm long Arms bracket,tapper plug,bolts nuts and screws incl aluminium painting etc as specified complete all as specified and directed including taking out existing damaged pole with street light bracket complete.

15

-

-

... More
Cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregates), in foundation and mass concrete etc complete all as specified and as directed.

10.8

-

-

... More
Cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregates) as in coping, blocks, bed plates, kerbs etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary formwork as required complete all as specified and directed.

3.6

-

-

... More
Supply and fix new generation ruby LED post top series IP 65 LED post-top 35 Watt, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source Clear Cover offers bright illumination for different applications including suitable dia of GI pipe and taking down old post top complete all as specified and directed be Engr in Charge.

60

-

-

... More
Material and Labour for Attending Faults/Trippings and rectifying /repairing the faults in street light panel/ Junction box/ cable fault/ connection/ busbar including PVC insulating Tapes/Nut bolts/lugs and all as specified and directed by Engineer-In-Charge. Note : Damaged/Burnt MCCB/MCB/cable/chageover switch will be measured and paid separately)

200

-

-

... More
Supply only MCCB,4Pole,250 Amps,25/36kA, 415Volts,50Hz AC including taking down old MCCB complete all as specified and directed by Engr-in-charge.

12

-

-

... More
Supply only MCCB,4Pole,160 Amps,25/36kA, 415Volts,50Hz AC including taking down old MCCB complete all as specified and directed by Engr-in-charge.

12

-

-

... More
Supply only MCCB,4Pole,100 Amps,25/36kA, 415Volts,50Hz AC including taking down old MCCB complete all as specified and directed by Engr-in-charge.

12

-

-

... More
Supply only MCCB,4Pole,63 Amps,25/36kA, 415Volts,50Hz AC including taking down old MCCB complete all as specified and directed by Engr-in-charge.

12

-

-

... More
Supply only Change Over Switch ,4Pole, 63 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC including taking down old changeover switch complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply only Change Over Switch ,4Pole, 100 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC including taking down old changeover switch complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply only Change Over Switch ,4Pole, 250 Amps, Open Execution,ON LOAD type 415Volts,50Hz AC including taking down old changeover switch complete all as specified and directed by Engr-in-charge.

2

-

-

... More
M&L for Earthing complete with galvanised steel earth plate electrode 60 × 60 cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.

60

-

-

... More
M&L in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 25 x 4 mm including taking down old strip complete all as specified and directed be Engr in Charge.

1200

-

-

... More
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as directed.

150

-

-

... More
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as directed.

80

-

-

... More
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as directed.

200

-

-

... More
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as directed.

180

-

-

... More
Supply, install, commission and testing LT panel board, outdoor type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof, front and rear operated door with necessary locking arrangement with MS-75 for base frame and angle iron 50 x 50 x 6 mm for legs , four nos legs 750 mm long and CRCA sheet of outdoor type duly powder coated both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity aluminum bus bar (1.5 times the incoming switch gear current rating) complete all as specified and as directed with the following accessories :- INCOMING (a) MCCB 4 pole, 415 Volts, 400 Amps, 36 KA - 02 Nos with adjustable thermal and magantic release with Ics=100 Icu (b) Change over switch ON LOAD type, 415 volt, 50 Hz, AC 4 pole in sheet steel enclosures, capacity 400 Amps rated current manually operated confirming to IS : 13947 or lates edition with hight thermal and dynamic strength to with stand short circuit current level of 80 KA rms, OUTGOING (a) MCCB 4 pole, 415 Volts, 320 Amps, 36 KA - 02 Nos with adjustable thermal and magantic release with Ics=100 Icu (b) MCCB 4 pole, 415 Volts, 250 Amps, 36 KA - 02 Nos with adjustable thermal and magantic release with Ics=100 Icu. (c) MCCB 4 pole, 415 Volts, 200 Amps, 25 KA - 02 Nos with adjustable thermal and magantic release with Ics=100 Icu. (d) MCCB 4 pole, 415 Volts, 100 Amps, 25 KA - 02 Nos with adjustable thermal and magantic release with Ics=100 Icu.

2

-

-

... More
Supply and fix AMFrelay suitable for 25KVA to 62.5KVA in existing AMF Panel and complete all as specified and directed by Engineer In Charge.

1

-

-

... More
Supply and fix AMFrelay suitable for 82.5KVA to 125KVA in existing AMF Panel and complete all as specified and directed by Engineer In Charge.

4

-

-

... More
Supply and fixing in replacement of Power Contactor ,100Amps ,4pole with 2NO+2NC suitable for 82.5KVADG set existing AMF Panel and complete all as specified and directed by Engineer In Charge.

1

-

-

... More
Supply and fixing in replacement of Power Contactor,130Amps ,4pole with 2NO+2NC suitable for 100/110KVA set existing AMF Panel and complete all as specified and directed by Engineer In Charge.

1

-

-

... More
Supply and fixing in replacement of Power Contactor,160Amps ,4pole with 2NO+2NC suitable for 125KVA set existing AMF Panel and complete all as specified and directed by Engineer In Charge.

3

-

-

... More
Supply & fix electrical Insulating mat confirming to IS15652/2006 (superceding IS: 5424-1969) B.I.S+CPRI+NTH+ERDA approved of C class of mats dielectric strength 65KV, sheet thickness not less than 3.0MM using at power houses including pasting of rubber mats with adhesive resin all as specified and directed by Engineer-in-Charge.

150

-

-

... More
Material and labour for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.

30

-

-

... More
Supply and fix cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 70 t0 95 sq mm and all as directed by Engineer-In-Charge.

12

-

-

... More
Supply and fix cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 120 to 185 sq mm and all as directed by Engineer-In-Charge.

10

-

-

... More
Supply and fix cable jointing STRAIGHT THROUGH JOINT for 1100V grade cable for straight through joint complete with Jointing material (Heat shrinkable)and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 240 to 300 sq mm and all as directed by Engineer-In-Charge.

10

-

-

... More
M&L for High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 90 mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.

550

-

-

... More
M&L Chequered plate thickness as per site requirement including cutting to required shape and appling two coat of synthetic enamel paint over a coat of red oxide and all as directed

1200

-

-

... More
Material and labour for Angle Iron of size as per site requirement and square bar applying two coats of synthetic enamel paint over a coat of red oxide primer and all as directed

150

-

-

... More
Supply & fixing power pack ,230V AC input, 30V DC /110Volt DC out put suitable for VCB/OCB 11 KV as power back complete all as specified and as directed.

20

-

-

... More
Supply and fix in repair MCCB four pole 400 amps 415 volt , 50 Hz breaking capacity not less than 25/36 KA complete all specified and directed by Engr-in-Charge.

14

-

-

... More
Supply and fix in repair MCCB four pole 320 amps 415 volt , 50 Hz breaking capacity not less than 25/36 KA complete all specified and directed by Engr-in-Charge.

12

-

-

... More
Taking down old unserviceable ACB any type and Supply, installation testing and commissioning new LT ACB of 1000 Amps four pole mannual draw out microprocessor based, 415 Volts, 50 Hz suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar /nut bolts/lugs complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Taking down old unserviceable ACB any type and Supply, installation testing and commissioning new LT ACB of 800 Amps four pole mannual draw out microprocessor based, 415 Volts, 50 Hz suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar /nut bolts/lugs complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Taking down old unserviceable ACB any type and Supply, installation testing and commissioning new LT ACB of 630 Amps four pole mannual draw out microprocessor based, 415 Volts, 50 Hz suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar /nut bolts/lugs complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply & install, testing and commissioning of outdoor type cubicle panel board, 415 V, 3 phase, 4 wire, aluminium bus bar of rating 400 Amps, made out of 3.15 mm thick CRCA sheet , factory fabricated , CPRI approved , powder coated(seven tank processed) with approved shade ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50 x 50 x 6 mm thick angle iron , grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery, cable glands, cable lugs, bus bar, MCCB fixed vertically with bus bar and panel both side (front and back) openable etc all as specified and comprising of following including necessary PCC work, cable connections to the MCCBs digital multifunction meter and cable lugs etc . :- (a) MCCB 4 Pole, 415V, 50Hz adjustable magnitic & thermal type, 400 Amps with breaking capacity 35KA. - 01 No. (Incoming). (b) MCCB 4 Pole, 415V, 50Hz adjustable magnitic & thermal type, 160 Amps with breaking capacity 25KA. -05 Nos (Out going). (c) Digital multifunction meter for 3 phase supply showing voltage, current, Frequency, PF, KWH - 01 No. (d) Phase indicating lamps LED type ( Red , Yellow, Blue) - 01 set

1

-

-

... More
Supply & install, testing and commissioning of indoor type AMF panel for automatic operation of the DG set, comprising of main and DG contactor , auto unit timers , relay , metering (Ammeter & volt meter), fuses (indicator lamps) , incoming MCCB 63 Amps 04 pole, cubicle panel board, 415 V, 3 phase , 4 wire, aluminium bus bar of rating 200 Amps, made out of 3.15 mm thick CRCA sheet , factory fabricated , CPRI approved ,powder coated (seven tank processed) with approved shade ,dust and vermin proof , provision for ventilation , angle iron frame and four legs of 50 x 50 x 6 mm thick angle iron , grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly and of suitable size to accomodate the items mentioned below and having separate compartment /chambers for cable gallery, cable glands, cable lugs , bus bar, MCCB fixed vertically with bus bar and panel both side (front and back) openable etc all as specified and directed & comprising of including necessary PCC work, cable connections to the MCCBs digital multifunction meter and cable lugs etc .

1

-

-

... More
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, single phase,10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specifed and directed by Engr in Charge.

120

-

-

... More
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 415 V, 3 Phase, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specifed and directed by Engr in Charge.

15

-

-

... More
Taking down old APFC panel and Supply, installation, testing and commissioning of 150/175/200 kVAr new APFC panel suitable for 500 KVA transformer totally enclosed, metal clad, sheet steel fabricated, fixed feeder type, dust and vermin proof, free standing , floor mounting type . The enclosure shall be pre treated as per 9 tank process and finished with powder coating of shade RAL 7032. The panel shall be factory OEM . The panel should be as per IEC 61439 & IEC 61921, rated system voltage 440 volt, short circuit rating more than 35 KA, altitude 1000 m, ambient temperature -5 degree C to 45 degree C, power supply 3 phase 4 line , relay current input signal 5A from CT online. The load bearing structure is made of 2 mm sheet steel and the front door and partition are made of 1.6 mm thickness IP 42. The capacitor element used in unit shall be metallized polypropylene film having low loss dielectric impregnated with such impregnant, which shall have high dielectric constant , low viscosity and high chemical stability. The operating temp of capacitor shall be 65 degree centigrade. The capacitor shall have maximum operating loss of 0.45 W/ KVAR. The capacitors shal have miximum 250 % overload current carrying capacity or rated current. The maximum inrush current carrying capacity of capacitor bank shall be 350 times of capacitors bank rated current. The maximum switching life of capacitor banks shall be 1500 switching/ years complete with internal wiring of panel with coding system all as specified and directed by Engr-in- charge. Note- Capacitor Bank designed by OEM for 500 KVA distribution transformer.

2

-

-

... More
Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1250Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete and unserviceable item will be paid seprately as supply only under item No 59 to 69 of this schedule.

10

-

-

... More
Supply only Spring Charging Handle suitable for upto 1250A ACB complete all as specified and directed.

4

-

-

... More
Supply only CT's suitable for air circuit breakers of rating 630Amps complete all as specified and directed.

5

-

-

... More
Supply only CT's suitable for air circuit breakers of rating 800Amps complete all as specified and directed.

4

-

-

... More
Supply only CT's suitable for air circuit breakers of rating 1250 Amps complete all as specified and directed.

5

-

-

... More
Supply only Auxiliary contact block suitable for air circuit breakers of rating 630Amps to 1250 Amps complete all as specified and directed.

6

-

-

... More
Supply only arcing (fixed/moving) suitable for air circuit breakers of rating 630 Amps to 1250Amps complete all as specified and directed.

4

-

-

... More
Supply only arc chutes (for 415V) suitable for air circuit breakers of rating 630Amps to 1250Amps complete all as specified and directed.

4

-

-

... More
Supply only shunt release(110/220V DC or 240V/415V AC) suitable for air circuit breakers of rating 630Amps to 1250Amps complete all as specified and directed.

5

-

-

... More
Supply only cluster contact suitable for air circuit breakers of rating 630Amps to 1250Amps complete all as specified and directed.

5

-

-

... More
Supply only trip coil suitable for air circuit breakers of rating 630Amps to 1250Amps complete all as specified and directed.

6

-

-

... More
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole,630 Amps,35kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.

2

-

-

... More
Taking out old unserviceable UPS and Supply and fixing UPS (inverter) 5 KVA /180 VDC three phase AC input 300 to 450 V. (a) Isolation transformer for 60 min back up single phase AC input 300 to 450 V and out put 230 ± 1% - 01 No (b) 30 Miniuts backup 12 Volt/ 26 AH SMF batteries with battery links - 15 Nos (or as per 60 mints backup for 5 KVA load) (c) Stainless steel battery rack with links, nut, bolts etc with all accessores for fixing of 15 Nos of battery - 01 No.

1

-

-

... More
Supply of PVC DLP - On wall trunking 195MMX50MM with 2 Compartment with all finishing accessories (end, joint of lid, joint of body,interior angle, exterior angle, flat angle, derivation) confirming standard EN 50085-2-1.Trunking should accept Wiring device with all the functions by associating the accessory of installation.Trunking should confirm to the current specifications of NF C 68-104 in terms of both performance and level of functions provided by the system. Installation trunking (which carries electrical wiring accessories) should be type 3 (installation)in the new standard.Material should be Non-flame propagating. Degrees of protection provided by enclosure should be IP 40. Protection against mechanical impact should be IK 07. Trunking should be delivered in length of 2m. The trunking covers and partitions should be in PVC white RAL 9003.The accessories should be in plastic ABS white RAL.

140

-

-

... More
(i) FLEXIBLE COVER 85MM WIDTH

280

-

-

... More
(ii) CLIP ON PARTITIONS

140

-

-

... More
(iii) BASE JOINT

70

-

-

... More
(iv) JOINT FOR 85MM WIDTH COVER

140

-

-

... More
(v) INTERNAL ANGLES-ADJ FRM 80 DEG

20

-

-

... More
(vi) EXTERNAL ANGLES-ADJ FRM 60 DEG

20

-

-

... More
(vii) FLAT ANGLE FOR 195X50-DLP TRU

20

-

-

... More
(viii) END CAPS

17

-

-

... More
Supply and fix in repair sub-main wiring with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC casing and caping of suitable dia, ISI marked including 1 single core cable with stranded copper conductor of size 10 sqmm (green colour) for earthing including taking down old unsv submain wiring complete all as specified and directed. Note :- (i) Four runs of 10 Sqmm cable, 1 run of PVC casing & caping and 1 run of 10 Sqmm cable for earth shall be measured as 1 RM. (ii) Each sub-main wiring shall run in seperate PVC casing caping

550

-

-

... More
Supply and fix in repair Mild Steel Galvanized Coating Powder Coated Cable Tray with top cover single compartment of size 300 mm x 50 mm x 2.0 mm for carrying of LT cable of suitable size fixing on wall/ angle iron along with all necessary fixing accessories ( bracket, nut bolts, washer, fastner) all as spcified and directed by Engineer-in-Charge.

246

-

-

... More
Supply and fix in repeir sub-main wiring with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing and caping of suitable dia, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing including taking down old unsv submain wiring complete all as specified and directed. Note :- (i) Two runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each sub-main wiring shall run in seperate PVC casing caping

900

-

-

... More
Taking down old unserviceable flood lights and supply and fixing 250 watt LED flood light with cast aluminum housing , toughened glass cover, high power LED, second optics , IP 65/66 , 10KV SPD, 100lm/watt, and wired with all complete accessories complete all as specified and directed.

25

-

-

... More
Taking down old unserviceable flood lights and supply and fixing 150 watt LED flood light with cast aluminum housing , toughened glass cover, high power LED, second optics , IP 65/66 , 10KV SPD, 100lm/watt, and wired with all complete accessories complete all as specified and directed.

22

-

-

... More
Taking down old unserviceable flood lights and supply and fixing 120 watt LED flood light with cast aluminum housing , toughened glass cover, high power LED, second optics , IP 65/66 , 10KV SPD, 100lm/watt, and wired with all complete accessories complete all as specified and directed.

22

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.