Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Sep 2024
Closing Date21 Oct 2024
Tender Amount₹ 39,99,000
Costs
EMD
₹ 79,980Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_675186_1Bid Award Id
ViewTender No
8603 GE South PuneTender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Dismantling unserviceable galvanized earth steel wire 3.15 or 4 mm dia and existing hexagonal cradle guard HT/LT poles and removing binding wire and removal of the same from site complete all as specified and directed by Engineer-in-Charge.
0.2
-
-
Dismantling old ACSR conductor any size from over head lines, poles by removing binding wire, service wire, cables and removal from site, complete all as specified and directed.
0.5
-
-
Dismantling insulator any type/ any size from LT poles, complete all as specified and directed.
12
-
-
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil complete all specified and as directed.
380
-
-
All as per Serial item No 7.00 above but depth exceeding 1.5 mtr and not exceeding 3.00 mtr , complete all as specified and directed.
0.3
-
-
Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point, complete all as specified and directed.
92
-
-
Returning filling in incl spreading leveling watering and well ramming in layers n. exc 25cm thick, complete all as specified and directed.
288
-
-
Material & labour cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and directed by Engineer- in-charge.
9
-
-
Material & labour PCC 1:3:6 type C-1 (using 20 mm graded mechanically crushed stone aggregate) as in stays and coping of poles including necessary form work complete all as specified and directed.
1
-
-
M&L for making of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique of minimum up to depth of 1.5 meters with and including necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as directed by Engr-in-charge
25
-
-
Supply, fixing and errecting in true vertical position of steel tubular swaged pole swan neck type single arm 9 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, conforming to IS-1678 including painting with anti corrosive black bituminous paint internally complete and externally up to planting depth and exposed portion with Aluminium paint two coats over a coat of red oxide primer including taking down of old unserviceable / damaged pole complete all as specified and directed by Engr-in-charge.
(Note : Excavation and earth work, PCC for foundation and coping shall be measured and paid seperately under respective item of BOQ)
12
-
-
Supplying and fixing in replacement galvanized stay stranded wire of size 7/4 mm and fixing to stay assembly complete all as shown in electrical plate No 1 of SSR-2009 (Part-I) complete all as specified and directed.
0.25
-
-
M & L for GI Stay assembly set comprising of 14 mm dia 400 mm iron stay bow, 2150 mm long stay rod 20 mm dia, stay plate 300 x 300 x 6 mm thick complete with all aceessories as shown in electric plate no 1 of MES schedule Part I, complete all as specified and directed.
Note :- Earth work, PCC, loop type insulator, galvanized stay stranded wire will be measured separately.
1
-
-
S&F in repairs cable route indicator made out of 3 mm thick MS sheet of suitable size (As approved by Engr-In-Charge) duly painted with two coats black paint over a coat of red oxide primer and writing cable direction, Nature of cable, size of the cable (in Sqmm), type of cable (LT Cable) with white paint, mounted on angle iron 40X40X3mm, angle height 45 cm, (30 cm below ground level) grouting with PCC 1:2:4 type B-1 as in foundation of size 20 cmX 20cm X 20 cm complete all as specified and directed by Engr-In-Charge.
20
-
-
Material & labour for Cross Arms, bracings supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps stay clamps, D clamps nuts, bolts , washers welding bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
8
-
-
Supply and fixing of cradles, hexagonal / Rectangular, fabricated with galvanized steel wire 4 mm dia including stretching, sagging and jointing in position as a continuous earth wire on pole and for guarding complete all as specified and directed by Engineer-in-Charge.
0.2
-
-
Supply and fixing Aluminium conductor steel reinforced (ACSR) of any size for LT OH lines on poles including stringing ,binding with aluminium wire 14 SWG or aluminium tape including jumpers complete connecting of disconnected cable, service cable and street light connection complete all as specified and directed by Engr In charge.
0.5
-
-
Supply and fixing insulatiors pin type LT 1100 Volts grade porcelain vitreous white or brown including one galvanized mild steel spindle, two galvanized iron washers, iron nut, 100 mm height, 65 mm dia complete all as specified and directed by Engineer–in-charge.
6
-
-
Supply and fixing shackle type insulator LT 1100 volt grade porcelain vitreous white or brown including insulator bolts, nuts 12 mm dia, 75 mm height and 90 mm dia of insulator complete all as specified and directed by Engineer-in-Charge.
6
-
-
Prunning / trimming the branches of trees if any along overhead line, 3 mtr on all side below/ above/ sides of overhead line and removing the same upto 150 mtr away, each span not exceeding 45 mtr complete all as specified and directed by Engineer-in-Charge (Note- The above work shall be caried out for the entire contract period by cutting / trimming of trees any number of times as required at site).
60
-
-
M&L for Stringing / stretching , including jointing in situ of each span not more than 45 Mtrs between two electric poles having 4 nos. of ACSR of any size with and including GI earth continuity wire, with / without guarding wires on electric poles of any size at different locations all as ordered manually or by telephonically means to the extent of permissible sag limit or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete as ordered, complete all as directed by Engr-in-charge. Note :- One span including 4 wire of LT over head line and two nos of earth wire.)
50
-
-
All as per serial item no 24 above but for two wires, complete all as directed by Engr-in-charge. Note :- One span includes 2 wire of LT over head line and two nos of earth wire.
30
-
-
M & L for replacement for PVC separator in position to keep ACSR conductor as equal spacing suitable for 2 Wire system, complete all as directed by Engr-in-charge.
12
-
-
M & L for replacement for PVC separator in position to keep ACSR conductor as equal spacing suitable for 4 Wire system, complete all as directed by Engr-in-charge.
12
-
-
Supply and fix in repairs GI Strip 32mmx6mm in any position , bending in shape and fixing in position with suitable size GI nuts, bolts & washers or by welding, complete all as specified and directed.
40
-
-
Supply and fix in repairs of aluminium strip 25 mm x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed by Engr-In-Charge.
40
-
-
S & F 1100 volts grade heavy duty flat cable of size 4 sqmm 2 core, PVC insulated aluminum solid conductor , served with inner sheathing of pvc tape and overall PVC sheathed in service connections suspended by insulating hangers not more then 1 mtr apart including replacing 4 mm suspension wire, complete all as specified and directed.
300
-
-
All as per item No.30 here in above but size 6 Sqmm 2 core, complete all as specified and directed.
400
-
-
All as per item No.30 here in above but size 10 Sqmm 2 core, complete all as specified and directed.
400
-
-
All as per item No.30 here in above but size 16 Sqmm 2 core, complete all as specified and directed.
300
-
-
Material & Labour painting of steel tubular LT poles including cross arms, clamps, back plates etc in situ on with one under coat and one finishing coat with aluminum paint after cleaning /preparation of surfaces including making white and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint and marking of pole No , Subsation No also, complete all as specified and directed.
200
-
-
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to with and including earth lead of 4mm dia GI wire up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth wire protected by galvanised iron 15 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing wire shall be encased in and including 15mm nominal bore GI 'light grade' tubing with all fittings from earth plate up to panel shall be provided & charcoal / salt funnel & other fittings etc. complete all as specified and as directed.
Note :- (i) GI earth wire and GI pipe 15mm bore medium grade for encasing GI earth wire upto 7.50m length per earthing shall be deemed to be included in the unit quoted rate.
15
-
-
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to with and including earth lead of 32x6 mm size GI strip up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth strip protected by galvanised iron 50 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing strip shall be encased in and including 50mm nominal bore GI 'light grade' tubing with all fittings from earth plate up to panel shall be provided & charcoal / salt funnel & other fittings etc. complete all as specified and as directed.
Note :- (i) GI strip and GI pipe 50mm bore medium grade for encasing GI strip upto 7.50m length per earthing shall be deemed to be included in the unit quoted rate.
12
-
-
Taking up underground cable of size 16 sqmm 2/4 core to 35sqmm 3.5core from trenches including bricks / PCC cable cover etc as required complete all specified and as directed.
1800
-
-
Taking up underground cable of size 50 sqmm 3.5 core to 95 sqmm 3.5core from trenches including bricks / PCC cable cover etc. as required complete all specified and as directed.
800
-
-
Taking up underground cable of size 120 sqmm 3.5 core to 185 sqmm 3.5core from trenches including bricks / PCC cable cover etc. as required complete all specified and as directed.
200
-
-
Supply and laying XLPE insulated armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core, complete all as specified and directed.
400
-
-
All as per Sch 'A' item No. 40 here in above but size 16 sqmm 2 Core, complete all as specified and directed.
400
-
-
All as per Sch 'A' item No.40 here in above but size 16 sqmm 4 Core, complete all as specified and directed.
400
-
-
All as per Sch 'A' item No. 40 here in above but size 25 sqmm 4 Core, complete all as specified and directed.
300
-
-
All as per Sch 'A' item No. 40 here in above but size 35 sqmm 3.5 Core, complete all as specified and directed.
300
-
-
All as per Sch 'A' item No. 40 here in above but size 50 sqmm 3.5 Core, complete all as specified and directed.
300
-
-
All as per Sch 'A' item No. 40 here in above but size 70 sqmm 3.5 Core, complete all as specified and directed.
250
-
-
All as per Sch 'A' item No. 40 here in above but size 95 sqmm 3.5 Core, complete all as specified and directed.
250
-
-
All as per Sch 'A' item No. 40 here in above but size 120 sqmm 3.5 Core, complete all as specified and directed.
100
-
-
All as per Sch 'A' item No. 40 here in above but size 150 sqmm 3.5 Core, complete all as specified and directed.
50
-
-
All as per Sch 'A' item No. 40 here in above but size 185 sqmm 3.5 Core, complete all as specified and directed.
50
-
-
Returning filling of excavated soil upto a depth of 30cm after riddling excavated soil (in lieu of sand) for cushioning of cable and re-filling of trenches with left over normal excavated soil, complete all as specified and directed by Engr-in-charge.
68.85
-
-
Taking out of existing cable covers of any type from cable trenches, complete all as directed by Engr-in-charge.
12000
-
-
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250x150x40mm complete all as specified and directed by Engr-in-Charge
9200
-
-
Laying only precast concrete cable cover of any type, complete all as specified and directed by Engr-in-Charge
Note- Serviceable cable cover obtained from item no. 52 have to be re-used under this item
2800
-
-
Supply and fixing in replacement of GI pipe, light grade, 40 mm bore , confirming to IS-1239, for cable protection on poles / walls / Road crossing / floor crossing with and including fittings & fixtures complete all as specified and directed.
12
-
-
All as per item No. 54 here in above but 50mm bore, complete all as specified and directed.
14
-
-
All as per item No. 54 here in above but size 80mm bore, complete all as specified and directed.
13
-
-
All as per item No. 54 here in above but size 100mm bore, complete all as specified and directed.
16
-
-
S & F in replacement of illuminated display board of size 1.28m x 0.2m x 0.9m (L x B xH) with Flex of Light Blue (MES Colour), Colour of letters shall be white, outer side fabrication bordered with Aluminium angle Frame of size 20x20mm x 3mm thick, inner side fabricated with 12mm MS square bar and aluminium sheet for top, bottom, back side, left side and right side of the display board, 50mm dia GI Pipe medium grade shall be fixed both side of board with 2 Nos. 30x4mm thick MS flat of 0.2m length welded to GI pipe and nut bolt and washer with display board not less than 2.50m and including PCC 1:4:8 for foundation type D-2 including all internal wirings and illuminated with and including LED 40 W Tube light fitting - 01 No., SMC/FRP Junction Box 140mm x 140mm x 95mm inner dimension make Sintex / National. The board must be openable from back side for maintenance of tube light, control wiring etc including its fixing arrangement and written Letters in capital not less than 10 letters and more than 40 letters, size of letters proportion with overall size of board complete all as directed by Engr-in-charge. Note : (i) Before manufacturing of Boards drawing and design of Board including colour of board will be approved by Engr-in-charge.
4
-
-
S&F Electric Shock Treatment Chart in Hindi , English and regional language laminated type of size 60 x 32 Cm (Approx) to be displayed in installations, completed all as directed by Engr-in charge.
8
-
-
M&L for MCCB TP, 25-100 Amps,16 KA, 415 volts Ics-100% Icu, Adjustable over load setting 0.8-1.0 x In and Adjustable short circuit setting 6-10x In with spreader links and separators Confirming to IS/IEC 60947-2, complete all as specified and directed.
10
-
-
All as per item No. 61 above but, rating MCCB TP, above 100 up to 125 Amps, 16 KA, 415 volts, complete all as specified and directed.
2
-
-
All as per item No. 61 above but, rating MCCB TP, above 125 up to 160 Amps, 16 KA, 415 volts, complete all as specified and directed.
2
-
-
All as per item No. 61 above but, rating MCCB TP, above 160 up to 200 Amps, 36 KA, 415 volts, complete all as specified and directed.
2
-
-
All as per item No. 61 above but, rating MCCB TP, above 200 up to 250 Amps ,36 KA, 415 volts, complete all as specified and directed.
1
-
-
All as per item No. 61 above but, rating MCCB FP, above 320 up to 400 Amps, 36 KA, 415 volts, complete all as specified and directed.
1
-
-
S&F in replacement of cylindrical panel locks of suitable size or as per sample including drilling, cutting and welding etc in panel sheets without disturbing to other existing fitments complete all as directed by Engr-in-charge
25
-
-
S&F in replacement of old broken cold rolled mild steel hinges of existing bus bar etc of suitable size or as per sample including welding and painting to match with existing colour of panel sheet etc complete all as directed by Engr-in-charge
25
-
-
S&F in repairs straight through (Heat shrinkable jointing kit) suitable for LT underground cable, 1.1 KV including cable connection on pole, complete all as specified and directed for the following sizes:-
(a) 16 to 35 Sqmm 3.5 Core
2
-
-
(b) 50 to 95 Sqmm 3.5 Core
3
-
-
(c) 120 to 185 Sqmm 3.5 Core
2
-
-
M&L for preparation of existing surface of LT panel and supporting surface of angle iron of LT Panel by scraping down, peeled off old paint, cleaning etc and applying one coat of smoke grey paint to LT Panel including cleaning of panels from inside by blowing compressed air etc complete all as specified and directed
30
-
-
Taking down LT panel / feeder pillar boxes from foundation complete all as specified and directed by engr-in-charge.
9
-
-
S&F including testing and commissioning LT Feeder Panel weather proof outdoor type double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 300 amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be showing the arrangements of circuit shall be pasted inside the panel door and covered with transparent laminated plastic sheet . The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x6mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint
1
-
-
and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both sided and suitable extended rotary handles for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not less than 1200mmX300mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earhting Terminals one on each side of the Panel with GI earth strip and including following accessories complete all as directed by Engr-in-charge:-
Note : The contractor has to taken approval of design of panels including size and length of the busbar before commencement of panel work and quoted rate includes cost of the drawings also.
(a) Incoming :-
(i) MCCB 4 pole 25 KA, 125 Amps capacity 415 V, 50 Hz, AC supply, IS marked, complete with all standard accessories - 01 No.
(b) Outgoing:-
(i) MCCB 3 pole 25 KA, 40-63 Amps capacity- 03 Nos.
(ii) MCCB 3 pole 63-80Amps 25 KA, 415V - 02 Nos. (iii) Digital Amps meter 0 to 150 Amps with selector switch - 01 No.
(iv) Digital Volt meter 0 to 500 volt with selector switch - 01 No. (v) Indicator lamp Red/Yellow/Blue - 03 Nos.
(vi) three CTs of ratio 400/5A class-1 burden 15VA- 01 Set.
(vii) MCBDP 40A,10KA-02 Nos. mounted on DIN channel.
-
-
-
(c) M&L for construction of platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate, 15 cm thick as in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding in PCC 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be constructed in such manner that it will be 60 cm above from the nearest road level. Drawing and size of platform will be provided by Engr-in-charge.
-
-
-
S&F including testing and commissioning LT Feeder Panel weather proof outdoor type double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 400 amp current rating. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent bus bars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be showing the arrangements of circuit shall be pasted inside the panel door and covered with transparent laminated plastic sheet . The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos. 50x50x6mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black
1
-
-
paint and grouted in PCC 1:3:6 at suitable depth as per site requirement. All MCCBs shall be provided with spreader links with phase separators on both sided and suitable extended rotary handles for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not less than 800mmX300mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos. of Earhting Terminals one on each side of the Panel with GI earth strip and including following accessories, complete all as directed by Engr-in-charge:-
Note : The contractor has to be taken approval of design of panels including size and length of the bus bar before commencement of panel work and quoted rate includes cost of the drawings also.
(a) Incoming :-
(i) MCCB 4 pole 25 KA, 250 Amps capacity 415 V, 50 Hz, , AC supply, IS marked complete with all standard accessories - 01 No.
(ii) Insulated Al bus bar 400 Amps-04 nos. mounted on epoxy insulators & housed in compartmentalised chamber.
(b) Outgoing:-
(i) MCCB 3 pole 16 KA,160 Amps capacity- 01 Nos.
(ii) Digital Amps meter 0 to 150 Amps with selector switch - 01 No. (iii) Digital Volt meter 0 to 500 volt with selector switch - 01 No. (iv) Indicator lamp Red/Yellow/Blue - 03 Nos. (v) Three CTs of ratio 400/5A class-1 burden 15VA- 01Set (vii) MCBDP 40A,10KA-02 Nos. mounted on DIN channel (vii) MCB, TPN, 63A,10KA-03 Nos. mounted on DIN channel
-
-
-
(c) M&L for construction of platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate, 15 cm thick as in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding in PCC 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be constructed in such manner that it will be 60 cm above from the nearest road level. Drawing and size of platform will be provided by Engr-in-charge.
-
-
-
S&F including testing and commissioning LT Feeder Panel weather proof outdoor type double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 300 amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be showing the arrangements of circuit shall be pasted inside the panel door and covered with transparent laminated plastic sheet . The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x6mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint
1
-
-
and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both sided and suitable extended rotary handles for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not less than 1000mmX300mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earhting Terminals one on each side of the Panel with GI earth strip and including following accessories complete all as directed by Engr-in-charge:-
Note : The contractor has to taken approval of design of panels including size and length of the busbar before commencement of panel work and quoted rate includes cost of the drawings also.
(a) Incoming :-
(i) MCCB 4 pole 25 KA, 160 Amps capacity 415 V, 50 Hz, , AC supply, IS marked, complete with all standard accessories - 01 Nos.
(ii) Insulated Al busbar 30mmx10mm - 04 nos. mounted on epoxy insulators & housed in compartmentalised chamber (b) Outgoing:-
(i) MCCB 3 pole 25 KA, 80-100 Amps capacity- 02 Nos.
(ii) MCB TPN 40A-02 Nos. on DIN channel
(iii) Digital Volt meter 0 to 500 volt with selector switch - 01 No
(iv) Digital Amps meter 0 to 150 Amps with selector switch - 01 No
(v) Indicator lamp Red/Yellow/Blue - 03 Nos.
(vi) Three CTs of ratio 400/5A class-1 burden 15VA- 01Set
-
-
-
(c) M&L for construction of platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate, 15 cm thick as in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding in PCC 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be constructed in such manner that it will be 60 cm above from the nearest road level. Drawing and size of platform will be provided by Engr-in-charge.
-
-
-
S&F including testing and commissioning LT Feeder Panel weather proof outdoor type double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 400 amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be showing the arrangements of circuit shall be pasted inside the panel door and covered with transparent laminated plastic sheet . The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x6mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint
1
-
-
and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both sided and suitable extended rotary handles for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not less than 1200mm X 300mm X 1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earhting Terminals one on each side of the Panel with GI earth strip and including following accessories, complete all as directed by Engr-in-charge:-
Note : The contractor has to be taken approval of design of panels including size and length of the busbar before commencement of panel work and quoted rate includes cost of the drawings also.
(a) Incoming :-
(i) MCCB 4 pole 25 KA, 250 Amps capacity 415 V, 50 Hz, , AC supply, IS marked, complete with all standard accessories - 01 Nos.
(ii) Insulated Al busbar 40mmx10mm-04 nos. mounted on epoxy insulators & housed in compartmentalised chamber
(b) Outgoing
(i) MCCB 3 pole 25 KA, 125-160 Amps capacity- 01 No.
(ii) MCCB 3 pole 80-100 Amps 25 KA, 415V - 01 No. (iii) MCCB 3 pole 40-63 Amps 25 KA, 415V - 04 No. (iv) Digital Amps meter 0 to 150 Amps with selector switch - 01 No
(v) Digital Volt meter 0 to 500 volt with selector switch - 01 No. (vi) Indicator lamp Red/Yellow/Blue - 03 No.
(vii) Three CTs of ratio 400/5A class-1 burden 15VA- 01 Set
-
-
-
(c) M&L for construction of platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate, 15 cm thick as in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding in PCC 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be constructed in such manner that it will be 60 cm above from the nearest road level. Drawing and size of platform will be provided by Engr-in-charge.
-
-
-
S&F in repairs DIN type HRC fuse link type HN of capacity 125 Amps, complete all as specified and directed.
2
-
-
S&F in repairs DIN type HRC fuse link type HN of capacity 160 Amps, complete all as specified and directed.
2
-
-
S&F in repairs DIN type HRC fuse link type HN of capacity 200 Amps, complete all as specified and directed.
2
-
-
S&F in replacement inverter RTC operational LED street light 45 Watts pipe mounted HSG made of pressure die cast aluminium alloy for effective thermal management (heat sink) excellent corrosion resistant tempered protective toughened glass or PC cover IP 66 LED street light, system wattage consist of max 45 watt composite / individual optical lens cover to ensure better uniformity. High efficiency long life SMD LED module with lumen efficacy110 lm/W within built emergency inverter operational principal i.e on emergency inverter light output -initial lumen at battery mode operate at 15-20% of rated Im within built RTC ON/OFF Timing Auto ON (Astro Sun set-30 mins) and Auto Off (Astro Sun Rise). Emergency Inverter back up 1.5-2 hrs at battery fully charge STC operation (3.7 v/ oooo WH Li-ion battery) CRI70,IP 66 Color temp 5700 K THD10% and PF0.95 Life class of 50,000 hrs @L70, Operating temperature -10 to+45 Degree Centigrade, input supply voltage Range 140-270 V Frequency 50-60 Hz, internal surge protection 5 KV Test certificate to be submitted, certification LM79 for luminaries LM 80 for LED source Make : HALONIX -HLSLD-ML04-45W-CWL-INV-RTC-R-B or equivalent make as approved, complete all as directed by Engr-in-charge
10
-
-
SS&F in replacement LED street light fitting 35 Watts, 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
8
-
-
S&F in replacement LED street light fitting 60 Watts, 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
9
-
-
S&F in replacement LED street light fitting 70 Watts, 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.directed.
7
-
-
S&F in replacement MPP Cylindrical Capacitor Fixed type 10 KVAR make - Schneider / VAC /L&T / Epcos, complete all as specified and directed.
3
-
-
S&F in replacement capacitor bank 5 KVAR capacity MPP, 440V 50Hz AC make L&T / Crompton Greaves / Meher / epcos, complete all as specified and directed.
5
-
-
S&F in replacement cooling fans sitable for capacitor panel heat dissipation of reputed standard make, complete all as specified and directed.
2
-
-
S&F in replacement Indicating Lamps (ON /OFF), Make - L&T / Schneider / Siemens, complete all as specified and directed.
18
-
-
M&L for replacement of outdoor type junction box made out of CRCA sheet 3mm powder coated comprising of epoxy coated aluminium bus bar 400 Amps - 04 Nos. drilled holes and GI nut bolts of suitable size for four nos. three phase four wire cables (3 Phase and 1 Neutral), Aluminium bus bars 1.20 m long mounted on insulator epoxy insulators with double covers and providing one MCCB 250 Amps, Four Pole, 415V, 25 KA housed in separate chamber, iron frame made out of angle iron of size 40mmx40mmx5mm at 60 cm clear height from ground level complete with grouting of angle legs of sufficient length in PCC 1:2:4 type B-1, complete all as directed by Engr-in-charge.
1
-
-
M&L for testing and find out the fault in LT underground cable with the help of by providing cable fault locating machine at site including removal of moisture content from cable complete all as directed by Engr-in-charge.
(Note:- (a). The fault locating machine will be arranged by the contractor at his own cost i.e the cost of bringing of fault locating machine at site shall be deemed to be included in unit quoted rates. (b). Necessary excavation and earthwork etc. will be measured and paid separately under respective items of BOQ
(c) Finding of one fault and make it functional will be measured as one Job.
12
-
-
M&L for 4mm dia galvanised or steel wire as in earth continuity wire or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing, complete all as specified and directed.
35
-
-
All as per item No. 89 above but 32mmx6mm galvanised iron strip, complete all as specified and directed.
20
-
-
All as per item No. 89 above but 25mmx3mm aluminium strip, complete all as specified and directed.
12
-
-
Surface excavation n. exc. 30 cm depth and averaging 15 cm depth and getting out in soft / loose soil including clearing away all grass and vegetation saplings, shrubs, bushes, undergrowth roots and removing rubbish up to a distance n. exc. 50 mtrs outside the periphery of the transformer/ 2 pole /4 pole structure/ feeder pillar area, complete all as specified and directed.
Note:-The contractor will ensure that no vegetation should grow during the contract period on the area so excavated.
600
-
-
S&F including testing and commissioning LT Feeder Panel weather proof outdoor type double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 1.5 times of incoming switch gear of current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size, properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be showing the arrangements of circuit shall be pasted inside the panel door and covered with transparent laminated plastic sheet. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos. 50x50x6mm thick angle iron supports of not less than each 1.0 m height duly painted with
1
-
-
anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement. All MCCBs shall be provided with spreader links with phase separators on both sided and suitable extended rotary handles for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not be less than 1800mmX300mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos. of earthing terminals one on each side of the Panel with GI earth strip with and including following accessories, complete all as directed by Engr-in-charge:-
Note : The contractor has to be taken approval of design of panels including size and length of the bus bar before commencement of panel work. The cost of drawing will be deemed to be included in unit quoted rates.
(a) Incoming :-
MCCB 4 pole 36 KA, 630 Amps capacity 415 V, 50 Hz, AC supply, IS marked, complete with all standard accessories - 01 No.
(b) Outgoing:-
(i) MCCB 3 pole, 25 KA, 200 Amps capacity with thermal adjusting Ics-100% Icu- 04 Nos.
(ii) MCCB 3 pole, 100Amps 25 KA, 415V with thermal adjusting Ics-100% Icu - 01 No. (iii) MCB, TPN, 40 Amps- 01 No., mounted on DIN channel (iv) MCB, SPN, 40Amps - 01 No. mounted on DIN channel (v) Digital Amps meter 0 to 150 Amps with selector switch - 01 No. (vi) Digital Volt meter 0 to 500 volt with selector switch - 01 No. (vii) Indicator lamp Red / Yellow / Blue - 03 Nos. (viii) Three CTs of ratio 600/5A class-1 burden 15VA- 01 Set
-
-
-
(c) M&L for construction of platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate, 15 cm thick as in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding in PCC 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be constructed in such manner that it will be 60 cm above from the nearest road level. Drawing and size of platform will be provided by Engr-in-charge.
-
-
-
S&F including testing and commissioning LT Feeder Panel weather proof outdoor type double door, fabricated out of 3.15mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 300 amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, ON, OFF & Trip LED indicating lamps at incoming. The panel shall be showing the arrangements of circuit shall be pasted inside the panel door and covered with transparent laminated plastic sheet. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x6mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable
3
-
-
depth as per site requirement. All MCCBs shall be provided with spreader links with phase separators on both sided and suitable extended rotary handles for incoming MCCB complete all as specified and as directed. The overall size of the panel shall not less than 1200mmX300mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos. of earthing Terminals one on each side of the Panel with GI earth strip with and including following accessories, complete all as directed by Engr-in-charge:-
Note : The contractor has to be taken approval of design of panels including size and length of the bus bar before commencement of panel work. The cost of drawing will be deemed to be included in unit quoted rates.
(a) Incoming :-
MCCB 4 pole 25 KA, 200 Amps capacity 415 V, 50 Hz, , AC supply, IS marked, complete with all standard accessories - 01 No.
(b) Outgoing:-
(i) MCCB 3 pole 25 KA, 80-100 Amps capacity with thermal adjusting Ics-100% Icu- 04 Nos.
(ii) MCCB 3 pole 40-50Amps 25 KA, 415V - 01 No. (iii) MCCB 3 pole , 50-63 Amps capacity, 25 KA – 01 No. (iv) MCB TPN 40A - 01 No. mounted on DIN channel (v) MCB SPN 40A - 01 No. mounted on DIN channel (vi) Digital Amps meter 0 to 150 Amps with selector switch - 01 No (vii) Digital Volt meter 0 to 500 volt with selector switch - 01 No (viii) Indicator lamp Red/Yellow/Blue - 03 Nos. (ix) Three CTs of ratio 150/5A class-1 burden 15VA- 01 Set
-
-
-
(c) M&L for construction of platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate, 15 cm thick as in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding in PCC 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be constructed in such manner that it will be 60 cm above from the nearest road level. Drawing and size of platform will be provided by Engr-in-charge.
-
-
-