Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Jan 2025
Closing Date10 Feb 2025
Tender Amount₹ 54,95,000
Costs
EMD
₹ 1,07,500Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_692869_1Tender No
CWE/KKE/TOKEN-29 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M&L for fine dust cushioning to under ground cable providing with a layer of and 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge
Note : Measurement shall be taken after gentling punning.
16
-
-
... More
Supplying and laying un-reinforced precast concrete HT cable cover, class HV, type 1 flat , size 300mm x 180mm x 40mm complete all as specified and directed.
900
-
-
... More
Demolition of stone slabs and tiles of any description or thickness laided bedded and pointed in cement mortar in floors, aprons etc.
2
-
-
... More
Demolition of cement concrete in ground floors and paving n exc 15 cm thickness ( below or above ground level) all as specified and directed.
2
-
-
... More
M&L for 100 mm thick cement concrete M-7.5 grade (Nominal Mix) using 40 mm graded stone aggregate finished even and fair as in sub base complete all as specified and directed.
20
-
-
... More
M&L for stone sett flooring with stone setts of size 200 to 150 mm long ,150 to 200 mm wide and 150 mm deep and sides dressed, bedded in cement mortar 1:3 joints 20 mm thick ; grouted in cemnt mortar 1:2 with an admixture of metallic floor harder 5% by weight of cement and struck flush complete all as specified and directed by Engr-in-Charge.
15
-
-
... More
All as per item no 9.00 above but except stone complete all as specified and directed by Engr-in-Charge.
5
-
-
... More
M&L for flush pointing 20mm thich to stone sett paving any decription in cement mortar 1:3 with an admixture of metallic floor harder 5% by weight of cement all as specified an directed .
20
-
-
... More
Removal of debris ( concrete, broken stone etc.) to out side defence land (distance exceeding 1.5 Km but 5Km from the site ) an depositing where directed.
2
-
-
... More
Supply, laying in replacement, in trenches/trenchless bore /ducts/fixing on pole or any location as indicated, XLPE insulated, screened, earthed, PVC bedded, galvanised steel strip, electric power cable (heavy duty) of following size with aluminium conductor suitable for 22 KV (E) grade as per relevent IS including latest amendment for IS testing, commissionong all as specified and directed including taking out of old burnt out cable as directed by Engr-in-Charge .
Note:- (i) Necessry tests to be conducted at site before and after laying of HT cable and reading shall be recorded jointly and test report to be submitted in triplicate to the Engineer-in-Charge. The cost of the same shall be deemed to be included in the unit rate quoted above.
-
-
-
... More
300 Sqmm 3 core
100
-
-
... More
120 Sqmm 3 core
100
-
-
... More
95 Sqmm 3 core
100
-
-
... More
Supply only laying HDPE pipe, 140mm dia (OD), PN-10, min wall thickness 8mm, ISI Marked, in trench or in trenchless bore, for protection of cable, in continuous length all as specified and as directed by Engr-in-Charge at site. Note: (a) Pipe should be continuous in length as per cable length, rate including jointing if required. (b) Rates for laying of pipe in underground boar included in the item No 13.00 above.
100
-
-
... More
M&L for servicing of HT vacuum circuit breaker (HT VCB) and SF6 breaker of capacity 630/800A/1250A, 22 KV, 350 MVA for servicing, repairs, replacement of defective/worn out parts / components and reassembling complete comprising of the following including testing and commissioning to the entire satisfaction of Engineer-in-Charge:-
Make of HTCBs :- Powercare Electrical , ABB (a) Dismantling the HTCB from the enclosure consisting of vacuum interrupter assembly, socket contacts , checking the serviceability of the parts carefully including cleaning, adjustments, replacement of defective/worn out parts and re-assembling the unit complete.
(b) Cleaning the external surface of bushings with CTC or Liquid ammonia to remove the accumulation of dirt or any other deposits. Inspection of bushings and make sure that vibration due to breaker operation have not caused the bushings to move resulting misallignment of contacts.
7
-
-
... More
(c) Checking the vaccum interrupter assembly and contacts. Checking the allignment of contacts and setting the contact surfaces to bare firm and uniform pressure and adjust the gap as per manufacterurs tolerance. Badly potted contacts needs to be replaced.
(d) Checking the breaker bushing of bus bar and circuit side inspecting the internal surface carefully for any charging/trackings,replacement of bushings.
-
-
-
... More
(e) Dismantling the spring charging mechanism of the HTCB, checking the operations of the closing/tripping through closing/tripping coils electrically as well as manualy charging including cleaning adjustments complete for smoothly functioning. (f) Checking the condition of the spring charging motor along with gear box including servicing to the motor commulator bushes, lubrication of bearing surfaces etc.
(g) Checking the ratchet wheel assembly, driving and charging parts for smooth functioning (h) Checking the operating mechanism of the breaker and ensure its operation freely through entire stroke. (j) Inspecting all bolts, nuts, pins and coller pins are in place and they are tight and opened properly.
(k) Inspection, cleaning and relubrication of circuit breaker
-
-
-
... More
M&L for servicing of HT oil circuit breaker (HT MOCB) of capacity 800/400A.22 KV, 350 MVA for servicing , repairs, replacement of defective/worn out parts / compounents and reassembling complete comprising of the following including testing and commissioning to the entire satisfaction of Engineer-in-Charge:- Make : Kirloskar Electric
26
-
-
... More
(a) Dismatling the HTCB by separating the upper chamber consisting of contacts and cross bar assembly from the oil tank, checking the serviceability of the following parts carefully including cleaning, adjustment,replacement of dffective/worn out parts (excluding parts) re-assembling the unit complete
(b) Drain out the oil from the tank, cleaning the tank by removing the sediments at the bottom, checking the condition of the tank liners and gaskets including replacement of defective gasket/tank liners. Testing of oil, if shows signs of moisture, carbonisation or dirt filtering and testing and replacement if necessary. Ensuring the oil guage indicating properly the actual oil level. Checking the condition of all gaskets to ensure that they are sealed properly and arrest any leakages by replaceing the gaskets or sealing the box outside and inside ,with necessery sealing material etc.,
-
-
-
... More
(c) Checking the operating mechanism of the breaker including cleaning, lubrication to all moving parts of the breaker mechanism like hold on catch assembly, trip bridge, trip lever and assembly, charging motor, belt, latchgear and worm gear assembly clutch shaft etc for proper operation both electrically and manualy. Checking the operating mechanism of the breaker and ensure its operation freely through entire stroke. Parts which shows excessive wear and tear to be replaced or adjusted as per manufacterurs tolerance. (d) Checking of operating voltage at mechanism terminals and tripping arrangement for positive tripping. Contacts to be examined for their condition and operation. Dress the pitted contactcts and replace if necessary. (e) Checking the raise /lower mechanism in three position(Draw out,test,service) and lubrication to the moving parts.
-
-
-
... More
(f) Review the adjustment of all pressure switches and lockout devices.
(g) Inspecting all bolts, nuts, pins and coller pins are in place and they are tight and opened properly.
(h) Inspection, cleaning and relubrication of circuit breaker
(j) Checking the auxiliary contact assembly, cleaning/replacement of contacts, adjustment of operating lever and lubrication to moving parts and apply petroleum jelly to the contacts.
-
-
-
... More
NOTEs for item No 15.00 & 16.00:- (a) Cost of additional hardwares like bolts,nuts , washers, spring washers, petrolium jelly or any other item not included in the list of supply only spare parts etc, to put the breaker in serviceable condition shall be deemed to be included under unit rate quoted . (b) The major spare parts requiered to be replced shall be measured and paid for separatly as "Supply only".
(c) Old unserviceable spare parts removed from the breakers shall be accounted for under schedule of credit (d) Contractor should visit the site before quoting the rates.
-
-
-
... More
Supply of following material for 630/800/1250A VCBs/SF6 of power care /ABB make complete all as specified and as directed.
Make of existing HTCBs :- Powercare Electrical , ABB
-
-
-
... More
Closing Coil 24V
4
-
-
... More
Closing Coil 110V
6
-
-
... More
Shunt Trip Coil 24V
4
-
-
... More
Shunt Trip Coil 110V
6
-
-
... More
Space heater
20
-
-
... More
Thermostat for strip heater
20
-
-
... More
Auxiliary Housing Assembly Male
2
-
-
... More
Auxiliary Housing Assembly female
2
-
-
... More
Emergency Trip handles
2
-
-
... More
Rachet wheel assembly
1
-
-
... More
Dust proof covers for bushings
6
-
-
... More
Male & Female contacts with necessary parts to connect breaker with bus bars
2
-
-
... More
Supply of following material for 800 Amps capacity MOCBs complete all as specified and as directed. Make of existing breaker : Kirloskar
-
-
-
... More
Fixed arcing contacts.
4
-
-
... More
Main fixed contacts with springs
4
-
-
... More
Oil seals for oil breaker
30
-
-
... More
Shunt trip Coil
8
-
-
... More
Closing Coil
8
-
-
... More
Rachet wheel assembly
1
-
-
... More
Aux Relay VAA 33, 110V DC 8NO & 8 NC
4
-
-
... More
Epoxy circuit spout insulator
2
-
-
... More
Male & Female contacts with necessary parts to connect breaker with bus bars
4
-
-
... More
fuse carrier of oil breaker
10
-
-
... More
M&L for Breaker/ transformer oil duly filtered ,dehydrated with minimum 60 KV di-electric strength.
210
-
-
... More
Spring charging motor 180W, 440 V, 3 phase as per sample
4
-
-
... More
Spring charging motor protection relay as per sample
20
-
-
... More
Repair /servicing / Maint/Reconditioning of breaker In-Out trolly, including proper allignment of wheels, wheel moving channel/rail, ramp etc, repairing of stoper pins, locking pins, replacement of dammaged wheels, fixing base etc complete for smooth operation of trolly for in/out and up/down etc complete all as specified and directed .
Note: The unit rate quoted shall be deemed to include necessary welding, bending, staightning work etccomplete.
33
-
-
... More
M&L decarbonising/cleaning / servicing complete HT panels board, 22 KV cubicle type, consists of bus bar chamber, circuit chamber and metering chambers, by opening the spout/bus covers inspecting the bus bar joints, cleaning of bus bars, checking the bus bar spouts and circuit spouts for any flash overs/tracks, applying Becktolred solution to the bus bars, tightening of joints, cleaning of bus bar insulators and bus bars with CTC and improving megger with inject to ensure proper decarbonisation and re-assembling complete including fixing of new bus bar supporting insulators if required to be replaced all as directed by Engineer-in-Charge. Note: Cost of new insulator shall be paid as supply only in respective item of this BOQ.
33
-
-
... More
Supply only HT bus bar supporting insulators as per existing size and shape suitable for 22 KV panel complete all as specified and directed .
100
-
-
... More
S&F in replacement including commissioning & testing of power pack rating 110 volt/230volt AC input 30 volt DC output for Auxiliary supply including necessary control wiring in existing HT panel complete all as specified and directed.
4
-
-
... More
M&L for overhauling / repairing /testing / calibrating the relays of HT breaker any type with disconnecting all connections and by conducting primary injection and secondary injection tests, checking with current transformer, rectification of defects in control wiring for proper tripping of circuit brakers through CTs and relays and tripping coils. adjustment/setting to plug and time multiplier settings of the relay to achieve the discrimination in tripping time of upstream brakers, re-installation of the relay in circuit complete all as specified and as directed by Engr-in-Charge at site.
NOTE:- (i) Contractor shall visit site before quoting the rate (ii) Contractor shall provide skilled staff for testing purpose as per specifiction and rates included for replacement of any unserviceable relay, necessary control wiring , testing, calibration, setting to load requirements etc., are deemed to be included in the rates quoted. The cost of only New relay will be paid as supply only rates under relevant item of this BOQ. (iii) Testing shall be carried out in presence of Engr-in-Charge.
15
-
-
... More
Taking down unserviceable electro mechanical relay and supply, install, testing and commissioning of microprocessor based numerical relay (over current + earth fault relay ) with high set, housed in drawout type metal case for panel mounting with complete including necessary control wiring all as directed by Engr-in-Charge at site. Make: L&T or equivalent in Schneider
Note:
(i) Contractor shall visit site before quoting the rates. (ii) Relay shall be set as per requirement. All the necessary retrofitting / alteration for fittings of this new type of relay are to be done by the contractor without extra cost.
10
-
-
... More
S&F digital type multifunction meter VAF, PF 3 Phase 4 wire AC 440 Volts 50 Hz of rating 5 Amps with Class 1.0 with Provision for housing the meter & control wiring with 2.5 Sqmm PVC insulated unsheathed multistranded copper conductor including testing & Commissioning complete all as specified and as directed by Engr-in-Charge. Make: L&T or equivalanet in Schneider
10
-
-
... More
Taking down unserviceable Master trip relay and and supply, install, testing and commissioning of new Master trip relay, to operate the trip coil at high speed, available with hand reset contact and hand reset flag, housed in drawout type metal case for panel mounting with complete including necessary control wiring all as directed by Engr-in-Charge at site. Make: L&T or equivalanet in Schneider
Note for Item No 26.00, 27.00 & 28.00 :-
(i) The Relays and meters to be fixed in existing Panel by suitable cutting fixing wiring connecting and complete testing etc. The rates quoted by the contractor are deemed to be inclusive of these misc. works.
(i) Contractor shall visit site before quoting the rate (ii) Contractor shall provide skilled staff for testing purpose as per specifiction and rates included for replacement of any unserviceable relay, necessary control wiring , testing, calibration, setting to load requirements etc., are deemed to be included in the rates quoted. The cost of only New relay will be paid as supply only rates under respective itemof this BOQ (iii) Compete testing shall be demonstrated to the concern JE after completion of work.
10
-
-
... More
S & F in reapirs Current Transformer 22 KV epoxy resin cast HT CT Ratio as per existing ratio or as required at site, dual core Class 5P 10 for protection, metering Class 1.0 as per existing size/shape suitable for optimum perforemance of relays all as specified and as directed by Engr-in-Charge at site. Make: Kappa/CG or equivalent. Note: contractor shall visit site before quoting the rate.
12
-
-
... More
S & F in reapirs Potantial Transformer 22 KV epoxy resin cast HT PT Ratio 22KV/110V Class 1.0 200 VA burden suitable for optimum perforemance of relays all as specified and as directed by Engr-in-Charge at site. Make: Kappa/CG or equivalent
12
-
-
... More
M&L for HT fuse for PT 22 KV, 3.5Amps to 10Amps, 25 KA breaking cap of rating as per existing for the particular HT panel as per existing shape and size tubular or box type complete with fuse holder all as specified and directed. Note: Existing fuses shall be checked at site and procurement shall be made as per existing sample.
10
-
-
... More
M&L for replacement of panel locks with panel key suitable for old panels as required at site complete all as specified and as directed.
30
-
-
... More
S&F in repairs PVC insulated, PVC inner sheathing, four core, multi stranded, copper conductor cable of size 2.5 sqmm suitable for breaker control wiring, complete all as specified and directed by Engr-in-Charge.
90
-
-
... More
S&F in repairs PVC insulated, PVC inner sheathing, 12 core, multi stranded, copper conductor cable of size 2.5 sqmm suitable for breaker control wiring, complete all as specified and directed by Engr-in-Charge.
90
-
-
... More
M&L for disconnecting HT/LT XLPE cable of any size from structure/pole/transformer for finding fault, defect rectification HT/LTcable laid in trenches or any location by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal or any type of strata required for exposing the cable fault. removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of any size. The fault locating equipments will be brought to site within the 6 hours of instruction from Engr-in-Charge as specified and as directed. Notes:-
i). Complaint will be notified to contractor on mobile phone at any time between 0800 hrs to 2200 hrs and will be rectified within 6 hours after notification, failing which Rs 500/- per day per complaint will be recovered. ii). Rates included necessary earth work in any type of strata or Road or Tank road for opening the cable and prepare the cable ready for jointing work and making good to match with existing finishes complete.
10
-
-
... More
S&F in repairs HT heat shrinkable indoor type end termination cable jointing kit suitable for 22 KV 3 core 120-185 sqmm XLPE aluminium conductor cable including disconnecting of cable and removing of old jointing kit complete all as specified and as directed.
4
-
-
... More
S&F in repairs HT heat shrinkable indoor type end termination cable jointing kit suitable for 22 KV 300 Sqmm 3 core XLPE aluminium conductor cable including disconnecting of cable and removing of old jointing kit complete all as specified and as directed.
4
-
-
... More
S&F in repairs HT heat shrinkable straight through cable jointing kit suitable for 22 KV 3 core 120-185 sqmm XLPE aluminium conductor cable including disconnecting of cable and removing of old jointing kit complete all as specified and as directed.
4
-
-
... More
S&F in repairs HT heat shrinkable straight through cable jointing kit suitable for 22 KV 300 Sqmm 3 core XLPE aluminium conductor cable including disconnecting of cable and removing of old jointing kit complete all as specified and as directed.
4
-
-
... More
S&F in repairs HT heat shrinkable indoor type end termination cable jointing kit suitable for 11 KV 3 core 95 sqmm XLPE aluminium conductor cable including disconnecting of cable and removing of old jointing kit complete all as specified and as directed.
4
-
-
... More
S&F in repairs HT heat shrinkable straight through cable jointing kit suitable for 11 KV 3 core 95 sqmm XLPE aluminium conductor cable including disconnecting of cable and removing of old jointing kit complete all as specified and as directed.
4
-
-
... More
M&L for preparation of steel surfaces of existing MOCB/ breaker cubical panel including cleaning/scrapping of old painted surface, removing all the scrapped of paint particals from the panel using the proper vaccum cleaner to the complete satisafication of engr-in-charge, applaying two coats of synthetic enamel paint by using of spray machine to finish the surface glosy of colour or/shade approved by Eng-in-charge commissioning of breaker after completing the job include marking of MES/SM No, incomoming, outgoing to or from etc all as specified and directed.
Note :-(i) The quoted rate is deemed to the inclusive of painting details pertaning to respective breaker like - details of CT & PT connected, details of transformer fed by respective HV breaker, etc all as specified by Eng-in-charge at site
30
-
-
... More
M&L for cement concreteM-7.5 grade (Nominal Mix) using 40 mm graded stone aggregate as in foundation for pole/ foundation for transformer or any other loction as per direction of Engr-in-Charge including necessary form work all as specified and directed
4
-
-
... More
M&L for Chemical Earthing complete with copper earthing rod 25mm outer dia electrode, including testing 3 mtr long and having suitable hole on top to connect earthing strip with copper nut bolts and washers, placed in ground in a bore 3.5 mtr drilled by Pneumatic boring machine and 50 Kg BFC coumpound having high moistue retaining capacity, earth pit cover made of reinforced FRP complete all as specified and as directed. Note:-
(i) Contractor shall visit site before quoting the rates.
(ii) Rates including demolition of old earthing. (iii) Contrctor shall provide all necessary safety measures during exectution the job and responsible for any loss to the Govt property during execution the job.
10
-
-
... More
M&L Earth continuity copper conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. of size 20x3mm all as directed by Engineer-in-Charge.
200
-
-
... More
M&L cross arms, bracing, supports, clamps and back plates MS sheet fabricated from structual steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size for repair to panels, duct cover and as indicted and inclusive of one primer coat one under coat and two finishing coat of aluminium /oil paint all as specified and as directed.
3
-
-
... More
M&L for replacement of batterry inter connecting lead / srtip with terminal and nut bolt mabe from lead metal as per sample for connecting of batterries in series of 200 AH all as directed at site.
18
-
-
... More
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC sheathed in service connections one twin core cable flat or circular of size 6 Sqmm all as specified and as directed
300
-
-
... More
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC sheathed in service connections one twin core cable flat or circular of size 10 Sqmm all as specified and as directed
300
-
-
... More
S&F in repairs PVC insulated, single core, multi stranded, copper conductor cable of size 2.5 sqmm suitable for panel wiring complete all as specified and directed by Engr-in-Charge.
300
-
-
... More
S & F for coloured machine pressed precast concrete interlocking paver block glossy finish (Two colour combination ) any shape and size confirming to latest IS of 60 mm thickness M-35 grade with grey cement and pigment laid over and including sand cuhsion not less than 25mm thick including taking down old paver block all as specified and as directed at E/M Installtion for Pathway or as directed by Engr-in-Charge at site. Note: Rate shall be deemed to be includedfor taking down old borken paver block of any type and stacking side for Schedule of Credit.
100
-
-
... More
S & F in repairs jumper connection between GOD and drop out fuses and transformers with Jummpers made with copper strip 20x3mm as a conductor duly insulated 1.5 mtr long with copper nut bolt and washers both ends and PVC sleeves, 22 KV grade, high tension, with colour code all as directed by Engr-in-Charge at site.
20
-
-
... More
M & L for Checking of DC circuit complete from batterry bank to HT panels for proper supply to HT panel cotrols for smooth fuctioning of panels complete all as spcified and directed.
2
-
-
... More
Supply only Fiber glass discharge rod, 33 KV, extendable type, as directed by Engr-in-Charge.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%