Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Jan 2025
Closing Soon15 Feb 2025
Tender Amount₹ 24,70,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply spreading in trenches dry crushed Stone sand for cable protection and punning down gently by hand all as specified.

25.28

-

-

... More
Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed.

3121

-

-

... More
Supply and fix Galvanized iron steel tubing Light grade of 80mm bore with all fittings as required at site and laid in floors/trenches as in cable protection all as directed by Engineer – in – Charge.

22

-

-

... More
Dismantling and Taking down L.T. under ground armored PVC insulated and PVC sheeted heavy duty 1100 Volts grade under ground cable of any size complete all as specified and directed.

635

-

-

... More
Supply and laying in the ground/ saddling through the wall/trenches of cable XLPE Insulated armoured, heavy duty electric power cables (heavy duty) 1100 Volts grade, cross sectional area with stranded aluminium conductor of size 10 sq mm 4 Core complete all as specified and directed.

200

-

-

... More
Supply and laying in the ground/ saddling through the wall/trenches of cable XLPE Insulated armoured, heavy duty electric power cables (heavy duty) 1100 Volts grade, cross sectional area with stranded aluminium conductor of size 16 sq mm 4 Core complete all as specified and directed.

170

-

-

... More
Supply and laying in the ground/ saddling through the wall/trenches of cable XLPE Insulated armoured, heavy duty electric power cables (heavy duty) 1100 Volts grade, cross sectional area with stranded aluminium conductor of size 25 sq mm 3.5 Core complete all as specified and directed.

140

-

-

... More
Supply and laying in the ground/ saddling through the wall/trenches of cable XLPE Insulated armoured, heavy duty electric power cables (heavy duty) 1100 Volts grade, cross sectional area with stranded aluminium conductor of size 35 sq mm 3.5 Core complete all as specified and directed.

125

-

-

... More
Supply and fixing in repairs/Replacement of of the undermentioned items to be incorporated in street light fittings complete all as specified and directed by Engineer-in-charge

-

-

-

... More
(a) LED Driver for 1 x 45 watt LED street light complete of make -Crompton/Bajaj/Havells or as per sample.

25

-

-

... More
(b) LED Driver for 1 x 60 watt LED street light complete of make -Crompton/Bajaj/Havells or as per sample.

22

-

-

... More
(c) LED Driver for 1 x100 watt LED flood light complete of make -Crompton/Bajaj/Havells or as per sample.

10

-

-

... More
(d) LED Driver for 1 x120 watt LED flood light complete of make -Crompton/Bajaj/Havells or as per sample.

9

-

-

... More
Supply and fix in repairs LED street light fittings 60 Watts 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, almp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed.

61

-

-

... More
Supply and fix in repairs LED street light fittings 35 Watts 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, almp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed.

40

-

-

... More
Supply and fix in repairs LED street light fittings 90 Watts 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, almp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed.

39

-

-

... More
S&F copper cable flexible PVC insulated 3 x 2.5 sqmm single core along with earth wire in PVC conduit from FRP box to street light fitting ,including aluminium flat clamp 25 X 4 mm -03 Nos with suitable nuts,bolts and washers etc all as specified and directed by Engr-in-Charge

156

-

-

... More
Supply & Fix in Replacement of GI Bracket made out of 40 mm dia medium grade GI tube up to 1.5 m long bend to shape 115 degree off set shape, fixed with 2 nos of suitable MS Flat clamp of size 40x5 mm with necessary nut bolts & washers and applying two coats of synthetic enameled paint over one coat of zinc oxide primer for clamp complete all as specified and directed.

16

-

-

... More
Material and Labour for painting of steel tubular pole 9 mtr long with one coat of aluminium paint including preparation old surface with scrapping of steel tubular poles Including numbering of pole no with black oil paint ,incl 2 strips of white & yellow paint , alternate upto a height of 1.2 mtrs complete all as specified and directed.

50

-

-

... More
Material and Labour for painting of Pre-stressed concrete pole 9 mtr long with one coat of white colour weatherproof snowsum paint including numbering of pole no with black oil paint ,incl 2 strips of white & yellow paint , alternate upto a height of 1.2 mtrs complete all as specified and directed.

70

-

-

... More
Supply and fix in replacement FRP cable looping box of size 250mm x 150mm x 100mm With connector block 4 Way , 1 Nos of MCB SP 6 Amp 10KA, etc including suitable Brass gland, including provision for connecting earth continuity conductor etc. all as specified and directed Make :- SINTEX / NATIONAL / NATRAJ.

39

-

-

... More
Material and labour for lowering of LED light fiitings mounting ring 20 Mtr to 30 Mtrs height carefully with help of highly skilled electrician and labours to mannually/electrically, Servicing Repair and replacement of spares of forward/reverse operation induction motor 3 phase 415 volts 2 HP capacity including greasing and oiling. Servicing of forward/reverse operation Gear box including greasing and oiling, dismantling and taking chain of motor to gear box, takindown unserviceable LED Light fittings and replacement of Suitable drivers of existing capacity/ Make its serviceable,supply and replace wire rope for lift side for suitable gauges/size,replacement of time with power contactor three phese 415 volts AC 32 Amps capacity, After repairing of LED light fittings tesiting and make serviceable of all fittings and lifting of mounting rings to existing places, After repairing of LED light fittings tesiting and make serviceable of all fittings and lifting of mounting rings to existing places complete all as pspecified and directed by Engineer-in-charge

2

-

-

... More
Supply and Fix LED flood light fitting 120 Watts Pressure die cast aluminium housing, heat resistant toughened glass with frame, IP66 protection better optics for uniform distribution make or equivalent of complete all as specified and as directed.

4

-

-

... More
S &F Street Light timer anylog type 24 hrs type with backlite fuse and ML4 of 32 Amps current rating contractor for automatic operation of street lights

2

-

-

... More
S &F Street Light timer anylog type 24 hrs type with backlite fuse and ML4 of 63 Amps current rating contractor for automatic operation of street lights

2

-

-

... More
S&F RYB indicator suitable for voltage rating 230 Volt AC complete all as specified and as directed.

1

-

-

... More
S&F Post top lantern LED type 40Watt 230 Volts AC Outdoor type with decorative post top for 360 dergee indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.

2

-

-

... More
M&L for periodical Servicing of Air conditioner Split type of capacities 1.5 to 2.0 TR complete with dismantling internal and external units into components , cleaning of components fan motor, blower, housing, filters etc.Checking up and rectification to wiring and connections,cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories, reallignment of the fan coil unit and replacement of drain / condense pipe , connecting up and testing, to make the unit in fully working condition complete all as specified and directed by Engineer-in-Charge. Note:1. Equipment Shall be serviced once in six months and no repeat maintenance shall be measured. Labour Charge for on site repairs is deemed to be included in the quoted rate of the job all as specified and directed.

35

-

-

... More
All as per Srl Item No 31.00 above here in before but for Airconditioner window type of capacity 1.5 TR all as specified and directed.

6

-

-

... More
Supply and fix only the following spares incorporated during the repairs to Air conditioner Split / Window type as pe above here- in- before but Supply and fix only Capacitor for AC 1.5 TR - 2.0 TR all as specified and directed.

40

-

-

... More
Supply and fix in repairs only Capacitor for Condensing Fan Motor all as specified and directed.

12

-

-

... More
Supply and fix in repairs only Starting Relay complete all as specified and as directed.

15

-

-

... More
Supply and fix in repairs only Evaporator Fan / Blower for for Window AC all as specified and directed.

16

-

-

... More
Supply and fix in repairs only Printed Circuit board for inverter split AC as per sample all as specified and directed.

25

-

-

... More
Supply and fix in repairs only Filter Drier complete all as specified and as directed.

20

-

-

... More
Supply and fix in repairs only Condenser Fan Motor for split AC 1.5 TR complete all as specified and as directed.

7

-

-

... More
Supply and fix in repairs only Condenser Fan Motor for split AC 2 .0 TR complete all as specified and as directed.

12

-

-

... More
Supply and fix in repairs only Compressor Sealed Unit for AC of capacity 2.0 TR all as specified and directed.

5

-

-

... More
Supply and fix in repairs only Compressor Sealed Unit for AC of capacity 1.5 TR all as specified and directed.

2

-

-

... More
Supply and fix in repairs only Condensor Unit for air conditioner complete all as specified and as directed.

4

-

-

... More
Supply and fix in repairs only Blower motor for Split type AC as per sample all as specified and directed.

5

-

-

... More
Supply and fix in repairs only Condenser Fan Motor for Window AC As per Sample all as specified and directed.

3

-

-

... More
Supply and fix in repairs only Thermostat Switch complete all as specified and as directed.

12

-

-

... More
Supply and fix in repairs only Swing motor for Split AC all as specified and directed.

14

-

-

... More
Supply and fix in repairs only Evaporator Fan / Blower for for Split AC all as specified and directed.

9

-

-

... More
Supply and fix in repairs only Cooling Coil all as specified and directed.

4

-

-

... More
Supply and fix in repairs only Over Load Protection Coil all as specified and directed.

8

-

-

... More
Supply and fix in repairs only Copper Capillary tube of Air Conditioner all as specified and directed.

7

-

-

... More
Supply & fix in repair including taking down old one out door unit cabinets with out compressor for split type AC of capacity for AC 1.5 TR all as specified and directed.

1

-

-

... More
Supply & fix in repair including taking down old one out door unit cabinets with out compressor for split type AC of capacity for AC 2.0 TR all as specified and directed.

1

-

-

... More
Supply & fix in repair including taking down old one indoor unit for split type AC of capacity for AC 1.5 TR all as specified and directed.

1

-

-

... More
Supply & fix in repair including taking down old one indoor unit for split type AC of capacity for AC 2.0 TR all as specified and directed.

1

-

-

... More
M&L for periodical repairs and maintenance of water cooler of cooling capacity upto40 /60 Ltrs / Hr and storage capacity upto 80 /120 Ltrs complete with disconnecting the water connection, inserting dead plug, dismantling the fan motor, taps, fan blades, condenser etc.Checking up and rectification to wiring and connections, replacement of necessary parts and accessories, cleaning of the cold water tank, piping, refrigerant lines, reallignment of the fan coil unit and replacement of drain pipe , connecting to water mains and testing to make the unit in fully functional condition. Note: 1. Equipment Shall be serviced once in 03 months and no repeat maintenance shall be measured. Labor Charge for On site repairs is deemed to be included in the quoted rate of the job.all as specified and directed.

5

-

-

... More
Supply and fix in repairs only the spares incorporated during the repairs to Water Cooler as per above herein before.- Thermostatswitch with knob

2

-

-

... More
Supply and fix in repairs only Push tap inner / outer thread chromimum plated of size 1/2 ".all as specified and directed.

3

-

-

... More
Supply and fix in repairs only Rubber gasket with PVC sheet for Top Lid all as specified and directed.

2

-

-

... More
Supply and fix in repairs only Condenser fan motor for water cooler.all as specified and directed.

2

-

-

... More
Supply and fix in repairs only Capacitor for water cooler all as specified and directed.

2

-

-

... More
Supply and fix in repairs only Starting Relay as per Sample all as specified and directed.

4

-

-

... More
Supply and fix in repairs only PVC Hose Pipe size 3/4 " to 1 " all as specified and directed.

5

-

-

... More
Supply and fix in repairs only Waste water tray as per sample all as specified and directed.

2

-

-

... More
Supply and fix in repairs only Compressor Sealed unit for water cooler of capacity upto 120Ltrs all as specified and directed.

2

-

-

... More
Supply and fix in repairs only Condenser unit for water cooler all as specified and directed.

2

-

-

... More
Supply and fix in repairs only Overload protection for Water cooler all as specified and directed.

6

-

-

... More
Supply and fix in repairs only Capillary tube of water cooler all as specified and directed.

2

-

-

... More
S & Fix in repairs ball brass valves, high pressure with Polyethylene float and flynut complete screwed for Iron pipe on or brass ferrule and fixed of size 15 mm dia all as specified and directed.

3

-

-

... More
Supply and fixing in repairs Sheet Metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB SP of Capacity upto 32 Amps 240 Volts all as specified and directed.

12

-

-

... More
S&F in repairs stop gun metal gate or globe valves with iron wheel head, screwed both ends for iron pipe and fixed complete of size 15 mm dia.all as specified and directed.

12

-

-

... More
Taking down geyser of capacity 25 to 50 Ltrs from the location after disconnecting electric and water connection carefully and sealing cable ends and water pipe for repair or removing to store for safe custody & stripping down, testing of tank, and connecting up carrying out repairs complete all as directed by EIC at site. Note: 1. Equipment Shall be serviced once in a Month and no repeat maintenance shall be measured. 2. Spare replaced during the process of repair shall be measured and paid separately as a supply only under relevant item here-in after.all as specified and directed.

25

-

-

... More
Supply and install in repair including taking down old one water heater storage type of capacity 25 liters glass lined coated inner tank, suitable for high pressure and pressure pump installation 02 KW heating elements fire retardant cable with 3 pin plug etc complete all as specified and as directed by EIC. Make: Havells/ Bajaj/Recold or Equivalent

12

-

-

... More
Supply and install in repair including taking down old one water heater storage type of capacity 50 liters glass lined coated inner tank, suitable for high pressure and pressure pump installatrion 02 KW heating elements fire retardant cable with 3 pin plug etc complete all as specified and as directed by EIC. Make: Havells/ Bajaj/Recold

4

-

-

... More
Supply and fix only the spares incorporated during the repair to geysers vide Sl Item no 43 herein before for Heating Coil 2 KW all as specified and directed.

10

-

-

... More
Supply and fix in repairs only Heating Coil 1.5 KW all as specified and directed.

9

-

-

... More
Supply and fix in repairs onlyThermostat all as specified and directed.

35

-

-

... More
Supply and fix in repairs only Copper Water tank for Geyser of capacity upto 25 Ltrs all as specified and directed.

2

-

-

... More
Supply and fix in repairs only Non return valve Brass Chromium plated 15 mm / 20 mm all as specified and directed.

8

-

-

... More
Supply and fix in repairs only Safety valve with anti vacuum pressure reducing HPRV all as specified and directed.

20

-

-

... More
Supply and fixing of PVC Cable entry tray of size 100 MM X 75 MM for entry of copper capillary tube and PVC hose pipe of water all as specified and directed. .

32

-

-

... More
S & F in repair ac stand outdoor unit as per sample all as directed all as specified and directed..

10

-

-

... More
M & L for refrigent charging /Top up to Air conditioners/water coolers complete all as directed and specified.

15

-

-

... More
Supply and fixing in repairs of insulation over and around copper tubing to be fitted across the whole length of copper tubing incl all fixing arrangements and checking for insulation leakages if any all as directed

20

-

-

... More
M&L for periodical Servicing of Refrigerator of any capacities complete with dismantling internal and external units into components , cleaning of components fan motor, blower, housing, filters etc.Checking up and rectification to wiring and connections,cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories, reallignment of the fan coil unit and replacement of drain / condensate pipe , connecting up and testing, to make the unit in fully working condition complete all as specified and directed. Note:1. Equipment Shall be serviced once in six months and no repeat maintenance shall be measured. Labour Charge for on site repairs is deemed to be included in the quoted rate of the job

2

-

-

... More
S & F in repair of freezer basket as per sample all as directed.

2

-

-

... More
S & F in repair of refrigerator locks as per sample all as directed.

1

-

-

... More
S & F in repair of refrigerator bulb as per sample all as directed.

2

-

-

... More
S & F in repair of handle as per sample all as directed.

1

-

-

... More
S & F in repair of defrost heater as per sample all as directed.

3

-

-

... More
S & F in repair of condensor coil of refrigerator as per sample.all as directed.

3

-

-

... More
S & F in repair of evaporator of refrigerator as per sampleall as directed.

1

-

-

... More
Supply and fix copper pipe of size 5/8 all as directed.

85

-

-

... More
Supply and fix copper pipe of size 1/4 all as directed.

60

-

-

... More
Supply and fix copper pipe of size 1/2 all as directed.

45

-

-

... More
Supply and fix NRV copper of size 1/4 and 1/2 all as directed.

8

-

-

... More
Supply and fix NRV Copper of size 5/8 all as directed.

4

-

-

... More
Supply and fix PVC Drain pipe of suitable Size all as directed.

30

-

-

... More
Supply and fix remote control for Splt AC as per site requirment and make at site all as directed.

3

-

-

... More
Supply only potable drinking water through water browsersfrom authorised water point (BMC) taken duly tested by BMC OR Govt approved Lab / SO Laboratory and decan into under ground sump of suitable Capacity of AGE E/M Air Force Station Mumbai for further pumping complete all as specified and directed. NOTE :- The quoted rate shall be deemed to include the following. (a) Cost of BMC charges for water supply in water tanker to be paid at BMC Officeas applicable.(b) Cost of conveyance.

142

-

-

... More
Supply Only "CALCIUM HYPOCHLORITE" in plastic drum (Having 60% to 70% available chlorine) ,complete all as specified and as directed by Engineer in Charge

180

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.