Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Pipe Line Project
Eprocure
Opening Date28 Jun 2024
Closing Date3 Sep 2024
Tender Amount₹ 38,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for cleaning thoroughly by using wire brush/coconut coir of walls and floor of Semi Under Ground Open Sump (SWT) of capacity 0.5 Lakh Ltr TO 0.9 Lakh ltr at COD and ODTD SWT and taking out all accumulated silt, foreign materials etc including disposal of materials n.exc. 50 mtr as directed and cleaning of chocked pipes etc by applying soda lime solutions with white primer one coat and writing Tank capacity by Paint all as directed.

5

-

-

... More
Taking up of Existing cast iron water mains (including all fittings) DI Pipe,with spigot and socket end sand lead joints including burning out joints and recovering lead of water pipe 100 mm dia all as directed... Note: (i) Earthwork will be measured and paid separately.(ii) Old unserviceable pipe to be deposited in MES store yard the cost including the transportation of old pipe from site to E/M store yard..

700

-

-

... More
All as per items no 05 here in before but size of water pipe 150 mm dia all as directed..

630

-

-

... More
All as per items no 05 here in before but size of water pipe 200 mm dia all as directed..

100

-

-

... More
Refixing only of Cast iron pipes with spigot and socket ends s centrifugally cast. Class LA,in any length,laid in trenches of water pipe 100 mm dia all as directed. Note:- cost of jointing and jointing material will be paid separately.

50

-

-

... More
All as per items no-08 here in before but size of water pipe 150 mm dia all as directed..

50

-

-

... More
All as per items no-08 here in before but size of water pipe 200 mm dia all as directed..

50

-

-

... More
Supply lay connect of water pipe 100 mm dia type DI-K7class in repair with push to lock rubber tighten lock centrifugally in any lengths conforming to IS including DI fittings & lead joints laid in trenches/ on wall/ on floor at locations all as specified & directed. Make : Electrosteel/ TISCO/ KESORAM Make: Jindal / Electro steel casting Ltd / Kalinga.

650

-

-

... More
All as per items no-11 here in before but size of water pipe 150 mm dia all as directed..

580

-

-

... More
All as per items no-11 here in before but size of water pipe 200 mm dia all as directed..

50

-

-

... More
Taking up unserviceable CI/DI fittings and supply and fixing any type radius and angle taper any type (Straight) bend increasing decreasing or double socket etc Tee pieces, single branch ‘Y’ junction double branch, coller, capacity and plugs for 100 mm bore to 200 mm bore CI pipe conforming to IS-1538- 1993 complete and all as specified.

400

-

-

... More
Taking up or down the GI Pipe 40/50/80mm size steel galvanized water tubing with all necessary fittings complete from walls / floor or trenches all as directed.

2370

-

-

... More
Cleaning,washing,descaling the of water pipe 40/50 mm dia serviceable GI pipe .Refixing/re-laying in same icluding necessary fitting/ fixture in same tranches or new location all as directed

320

-

-

... More
All as per items no-16 here in before but size of water pipe 80 mm dia.

200

-

-

... More
Supply & fixing the of water pipe 40 mm dia of GI steel tubings of medium grade with all fittings and fixed complete to walls/ ceiling or laid in floors all as directed.

550

-

-

... More
All as per items no-18 here in before but size of water pipe 50 mm dia.

1200

-

-

... More
All as per items no 18 here in before but size of water pipe 80 mm dia.

100

-

-

... More
M&L for cutting existing steel tubing for alterations or additions of pipes size 40/50 mm bore all as directed

18

-

-

... More
M&L for Screwing existing steel tubing for alterations or additions of pipes size 40/50 mm bore all as directed

18

-

-

... More
Taking up/down the following unserviceble gate valve of any type any size and Supply and fixing the Gate valve of water pipe 40 mm dia made with. Gun-metal,, with iron wheel head, screwed both ends on G.I pipes with GI union, all as per directed..

4

-

-

... More
All as per items no-23 here in before but size of water pipe 50 mm dia all as directed..

2

-

-

... More
Taking up unserviceable CI sluice valve of any size from existing pipe line all as directed.

2

-

-

... More
Supply and fixing and replacement of sluice valve 100 mm dia type PN-1.6 double Flanged cast iron type with brass spindle and iron wheel iron nuts, bolts & washers and rubber insertion sheet conforming to IS specification complete and all as specified. make -Cair/ Kirloskar/ BIR/ UPADHYA.

1

-

-

... More
All as item srl no 26 here in before but size of sluice valve 150 mm dia

1

-

-

... More
Repair of brick massonry valve pit chamber of inner dimension 100x100x100 cms suitable for sluice valves upto 100mm size, with , brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including MS sheet cover of thickness 2 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement and removing the debris from the site or as specified and all as directed.

2

-

-

... More
Repair of brick massonry valve pit chamber of inner dimension 120x120x120 cms suitable for sluice valves upto 100mm size, with , brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including MS sheet cover of thickness 2 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement and removing the debris from the site or as specified and all as directed.

2

-

-

... More
Repair of brick massonry valve pit chamber of inner dimension 150x50x150 cms suitable for sluice valves upto 100mm size, with , brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including MS sheet cover of thickness 2 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement and removing the debris from the site or as specified and all as directed.

2

-

-

... More
Repair of Defects such as leakage and blockage in CI/DI pipe of size 80 mm to 100 mm including neccesary excavation work upto 6 RM and depth up to 60 cm manually or by JCB (Extractor) and refixing again after cutting and jointing as per site requirement using new CI/DI fittings as required following sizes :- Note :- (a) fittings reqd will be paid in respective items (b) Diffects shoud be rectified within 24 Hrs of intimation oterwised recovery @ of rupees 300 per day will be carried out.

5

-

-

... More
Repair of Defects such as leakage and blockage in CI/DI pipe of size 150 mm to 200 mm including neccesary excavation work upto 6 RM and depth up to 60 cm manually or by JCB (Extractor) and refixing again after cutting and jointing as per site requirement using new CI/DI fittings as required following sizes :- Note :- (a) fittings reqd will be paid in respective items (b) Diffects shoud be rectified within 24 Hrs of intimation oterwised recovery @ of rupees 300 per day will be carried out.

5

-

-

... More
Supply lay connect of Fire water pipe 150 mm dia type MS in repair with welding for connection fire pump to distribution network in any lengths conforming to IS including necessary fitting complet all as directed. Make : Electrosteel/ TISCO/ KESORAM Make: Jindal / Electro steel casting Ltd / Kalinga.

10

-

-

... More
Supply lay connect of Fire water pipe 100 mm dia type MS in repair with welding for connection fire pump to distribution network in any lengths conforming to IS including necessary fitting complet all as directed. Make : Electrosteel/ TISCO/ KESORAM Make: Jindal / Electro steel casting Ltd / Kalinga.

10

-

-

... More
Taking out LT Cable of any size(25 sqmm 4 core to 70 sqmm 3.5 core) for reuse or under Schedule of credit to contractor. Note:- Excavation is not included in quoted rate and will be measured & paid separately.

350

-

-

... More
Supply ,laying ,commossionong,testing in repair UG cable 70 Sq mm x 3.5 core ,XLPE insulated screened PVC bedded ,galvanized steel strip or wire armoured ,electric power cable heavy duty 1100 volts grade with stranded aluminum conducter all as directed- Make :- Gloster/ Polycab/Vishal.

100

-

-

... More
All as per item no-36 here in before but size of cable 25 Sqmm x 4 Core all as directed.

100

-

-

... More
All as per item no-36 here in before but size of cable 50 Sq mm x 3.5 core all as directed.

150

-

-

... More
Taking down unserviceable feeder pillar/panel of any type any capacity,supplying, designing, fabricating, erecting, connecting, testing & commissioning outdoor type vermin & weather proof totally enclosed double door type feeder pillar box front and back operated with hood (Canopy) on top, sufficient ventilation on sides, cubicle type, compartmentable fabricated out of 3.15 mm thick CRCA sheet powder coated texture finish colour. The panel shall be erected on 50mm x 50mm x 6mm thick MS angle iron frame and shall be pre-wired with PVC insulated copper conductor cable for monitors & Heat shrinkable PVC insulated sleeves, copper strips of appropriate current carrying capacity for connecting the incoming and outgoing MCCBs including reconnecting of existing serviceable cable / new cable with lugs & Brass cable glands. The panel shall consisting of following accessories :- (i) Colour coded copper bus bar 400 Amp rating 3 Phase & Neutral. (ii) Epoxy insulator 16 Nos . (iii) Digital Volt meter 0 to 500 V with selector switch -01 Set (iv) Digital Ammeter with CT 0 to 100A with selector switch -01 set. (v) LED indicators R,Y &B - 01 Set. (vi) Angle Iron stand made out of 50x50x6 mm of suitable size & upto 0.6 mtr high above GL - 01 job. (vii) Internal connection to MCCBs/ MCBs with copper busbar/wiring - 01 Job. (viii) The panel shall provisioned compartments for fixing the following:- (a) MCCB 160Amp TPN,( as in comming)- 01 No. (b) MCCB 63 Amp TPN, (outgoing) - 02 Nos). (c) MCCB 40Amp TPN,(outgoing) - 02 Nos (d) DOL Starter suitable for submersible pump 10 HP-01 Nos Note: (1) The Feeder pillar panel should be front & back openable and hinged door lock handle (2) The door should be tightened with rubber gasket (3) Each compartment have door, lock and Main bus bar and MCCB input & outgoing connection should be suitable size copper bus bar, nut & bolts etc (4) All incomming & out going cable connected through new suitable size copper gland and aluminium lugs, nut & bots etc. (5) This item not include the cost of MCCBs & MCBs, This should be measured and paid as separate item remaining all accessories are included in this cost.

2

-

-

... More
Taking down the unserviceable submersible cable Supply ,laying ,connecting the same of size 10 sqmm PVC insulated 1100 volts grade with stranded copper conducter all as directed- Make :- Havells/ Polycab/Vishal.

50

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion

2

-

-

... More
Excavation in trenches Soft / loose soil not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all as specified and directed.

412

-

-

... More
Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed.

400

-

-

... More
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed.

12

-

-

... More
M&L for provision of PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.