Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Nov 2024
Closing Date10 Dec 2024
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684494_1Tender No
8475/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
All as item No 1.00 above but suitable for split type AC 2.0 Ton capacity.
12
-
-
All as per item No 1.00 above but suitable for Refrigerator 165/190/280/310 Ltrs. Capacity.
8
-
-
All as per item No 1.00 above but suitable for water coolers 40/60/80/100/150 Ltrs. Capacity.
5
-
-
Material and labour for detecting the gas lekage from window type AC 1.5 ton capacity of any make and type including pressure testing, rectification, vacuumising, charging fresh gas R-12/ R-22 as exists, testing and commissioning complete all as specified and directed
3
-
-
All as per item No 7.00 above but 2.0 Ton capacity window type AC.
2
-
-
All as per item No 7.00 above but of 1.5/ 2.0 ton capacity split type AC.
90
-
-
All as per item No 7.00 above but of 40/100/150ltrs. Capacity water cooler / refrigerator.
55
-
-
Supply and fix in repairs blower fan motor of 1.0/ 1.5/ 2.0 Ton capacity AC of existing make including testing complete all as specified and directed.
30
-
-
Supply and fix in repairs fan motor suitable for water cooler of any Capacity including testing complete all as specified and directed.
25
-
-
Taking out AC 1.0/ 1.5/ 2.0 ton capacity of any make from its original location removing the dust from body with blower cleaning the condenser & cooling coil by using water and caustic soda, painting the base tray with one coat of black synthetic enamel paint checking all the connections including functioning of metal clad socket/ DP switch, function of relay capacitors, overload protector, thermostat, fan motor blade, / blower drum etc oiling/greasing of fan motor checking serviceability changing the air filter woolen felt for air tightening complete & refixing it in its original place including commissioning and testing complete all as specified and directed.
130
-
-
Taking down corroded body base tray of window type AC 1.0Ton/ 1.5Ton/ 2.0Ton capacity and replacement of body base tray made out of MS sheet 18 SWG and other portion with 20 SWG including motor mounting frame fixed with and including nuts and bolts of suitable size including painting with two coats of synthetic enamel paint over one coat of red oxide primer and necessary insulation complete all as specified and directed.
3
-
-
Material and labour for preparation of old painted surfaces of Water cooler any capacity by complete scraping old painting an applying two coat of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed.
10
-
-
Material and labour for preparation of old painted surfaces of refrigerator any capacity by complete scraping old painting an applying two coats of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed.
10
-
-
Supply and fix in repairs fan blade of motor suitable for water cooler of any Capacity including testing complete all as specified and directed.
25
-
-
Supply and fix in repairs fan blade of motor suitable for window /split type AC 1.0Ton/ 1.5Ton/ 2.0 Ton capacity including testing complete all as specified and directed.
30
-
-
Supply and fix in repairs blower drum suitable for window type AC 1.0Ton/ 1.5Ton/ 2.0 Ton capacity including testing complete all as specified and directed.
15
-
-
Supply and fix in repairs outer cover for window type Air conditioner of any capacity and size made out of GI sheet 20SWG complete all as specified and directed.
4
-
-
Supply and fix in repairs front cover grill suitable for window type Air conditioner 1.0 Ton/ 1.5 Ton/ 2.0 Ton capacity AC of existing make complete all as specified and directed.
3
-
-
Supply and fix in repairs starting capacitor 60-80 mfd complete all as specified and directed.
20
-
-
Supply and fix in repairs starting capacitor 80-100 mfd complete all as specified and directed.
20
-
-
Supply and fix in repairs starting capacitor 100-120mfd complete all as specified and directed.
20
-
-
Supply and fix in repairs running capacitor 25MFD complete all as specified and directed.
30
-
-
Supply and fix in repairs running capacitor 36MFD complete all as specified and directed .
35
-
-
Supply and fix in repairs relay for window / split type AC of 1.0Ton/ 1.5Ton/ 2 Ton capacity complete all as specified and directed.
30
-
-
Supply and fix in repairs selector switch push button type suitable for window type AC of any make 1.0Ton/ 1.5Ton/ 2.0Ton capacity complete all as specified and directed.
6
-
-
All as per item No 28.00 above but rotary type complete all as specified and directed
3
-
-
Supply and fix in repairs thermostat switch suitable for window type/ split type AC of capacity 1.0Ton/ 1.5Ton/ 2.0Ton capacity complete all as specified and directed.
30
-
-
Supply and fix in repairs thermostat switch suitable for refrigerator of any capacity complete all as specified and directed.
20
-
-
Supply and fix in repairs thermostate switch suitable for water cooler of any capacity complete all as specified and directed.
25
-
-
Supply and fix in repairs Air filter suitable for window type/ split AC of any capacity and type complete all as specified and directed.
55
-
-
Supply and fix in repairs over load protector suitable for window type AC complete all as specified and directed.
35
-
-
Supply and fix in repairs electric bulb suitable of refrigerator of any capacity screw type/ pin type complete all as specified and directed.
5
-
-
Supply and fix in repairs sheet metal enclosure with 2 pin earth plug and socket complete with single pole MCB of 20 Amps complete all as specified and directed.
15
-
-
Taking down carefully split type AC of capacity 1.5/ 2.0 ton & refixing in new location including provision of frame work of MS angle iron/ flat iron for indoor unit and outdoor unit as per manufactures instructions duly painted with two coats of synthetic enamel paint over a coat of zinc chrome primer, making hole in the wall for pipes and making good disturbed surfaces as per existing surface and making connections complete all as specified and directed.
60
-
-
Supply fixing and clamping jointing copper tubing of standard size for suction line and for liquid discharge line duly insulated with and including nitrile rubber insulation material including making hole in wall for passing through and making good the disturbed surface complete all as specified and directed.
100
-
-
Supply and lay cable PVC insulated PVC unsheathed, multistranded, 1100 volts grade (ISI marked) 3 core 4 Sqm with copper conductor suitable for indoor unit to out door unit including taking out old cable complete all as specified and directed.
200
-
-
Supply and lay PVC flexible pipe 5/8" dia, heavy duty for drain out condensing water of split AC including cutting of floor/ making hole in wall and making good after laying of pipe to match the existing surface complete all as specified and directed.
500
-
-
Supply and fix in repairs push cock/ lifting cock for water cooler of any capacity.
15
-
-
Supply and fix in repairs GI water tray 2mm thick for window type AC any capacity with out let system connection provided with PVC pipe of 20mm dia up to 3meter length connecting to drain pipe complete all as specified and directed.
2
-
-
Supply and fix in repairs PVC drain pipe 25mm bore as out let drain, fixed to wall with necessary saddles or laid under floor complete all as specified and directed.
150
-
-
Supply and fix in repairs magnetic gasket suitable for refrigerator of 165/ 286/ 310ltrs capacity complete all as specified and directed.
8
-
-
Supply and fix in repairs relay suitable for water cooler of any capacity complete all as specified and directed.
15
-
-
Supply and fix in repairs relay suitable for refrigerator of any Capacity complete all as specified and directed.
30
-
-
Taking down carefully window type AC of capacity 1.5/ 2.0 ton & refixing in new location after cutting out existing wall, widow grill, existing window frame for making suitable space to accommodate window type AC and making frame with 2nd class hard wood scantling of size 50mm x 50mm for fixing of outer cover of AC & supporting structure made out of 40mm x 40mm x 5mm thick MS angle iron duly grouted in wall & closing the open space around ACs with the help of 6mm thick plywood exterior grade to close air leakage, tightening with wooden fillet and painting to wooden structure & steel structure with two coats of synthetic enamel paint over a coat of primer and making all connections complete all as specified and directed.
2
-
-
Supply and fix in repairs blower motor capacitor 4MFD complete all as specified and directed.
50
-
-
Supply and fix in repairs blower motor capacitor 6MFD complete all as specified and directed.
35
-
-
Supply and fix of Float valve suitable for Water cooler of any capacity incl taking down complete all as specified and directed.
20
-
-
Supply and fix in repairs electronic circuit (PCB) suitable for inverter based split type AC of any capacity, any make complete all as specified and directed.
25
-
-
Repairs to PCB of any capacity split AC including inverter based type by dismantling from indoor units carefully by diconnecting all internal communication cables and sensor supply, replace/ soldering damaged chip, electonic capacitors / transmitters/inductors/switches with new components and re install and connect to the split AC & testing complete all as specified and directed.
35
-
-
Replacement of indoor unit of split type AC 2.0 TR capacity having star rating complete with all accessories such as installation plate with screws, blower motor, swing motor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed.
2
-
-
Replacement of indoor unit of split type AC 1.5 TR capacity having 5 star rating complete with all accessories such as installation plate with screws, blower motor, swing motor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed.
2
-
-
Supply and fix in repairs condenser coil made out of copper pipe and aluminium fins suitable for Air conditioners/ water coolers including leakage checking, gas charging and testing complete all as specified and directed.
7
-
-
Supply & fix in repairs of sensor remote handset suitable for 1.5/2.0 Ton capacity split type AC complete all as specified and directed.
15
-
-
Taking out old unserviceable cooling coil of window/split type AC any capacity and any make with fins cutting in let outlet connecting copper pipe and providing new cooling coil with fins and connecting in let out let copper pipe by bracing and replacement of nut bolts complete all as specified and directed.
35
-
-
Supply and fix in replacement Contactor of split type AC any capacity complete all as specified and directed.
45
-
-
Supply and fix in replacement suction & liquid line valve of size (5/8"&1/4")/(5/8"&3/8") suitable for split type AC complete all as specified and directed.
40
-
-
Supply & fix Condensing unit Bracket of any size and type suitable for supporting to out door unit of split type AC including nut, bolts & washers complete all as specified and directed.
20
-
-
Replacement of outdoor unit of split type AC 1.5 TR cap upto and including 5 star rating complete with all accessories such as hermetically sealed compressor, condenser unit, capacitor, relays, fan motor etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed.
2
-
-
Replacement of outdoor unit of split type AC 2.0 TR cap upto and including 5 star rating complete with all accessories such as hermetically sealed compressor, condenser unit, capacitor, relays, fan motor etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed.
2
-
-
Maintenance & complete servicing of cold/cool room units by electrically disconnecting the units and cleaning the compressor, condenser , piping suction/ discharge suction, fan motor, cooling coils etc. and connected accessories with the help of blower unit, cleaning the same with water and caustic soda for condenser and piping unit, painting the cooler base by scrapping out rusted particle and apply two coats of anticorrosive black paint at corroded portion, tighten all nut bolts, screws etc checking the door bedding, electrical controls of the cooling units rectify where necessary, defrost the system dry & disinfect the inner portion using disinfect material and refixing in original site and testing complete for 04 Nos units of any capacity complete all as specified and directed.
12
-
-
Maintenance & complete servicing of Deep freezer units 04 Nos by electrically disconnecting the units and cleaning the compressor, condensor , piping suction/ discharge suction, fan motor, cooling coils, cooler body and connected accessories with the help of blower unit, cleaning the same with water and caustic soda for condensor and piping unit, painting the cooler base by scrapping out rusted particle and apply two coats of anticorrosive black paint at corroded portion, tighten all nuts,bolts, screws etc checking the door beding, electrical controls of the cooling units rectify where necessary, defrost the system dry &disinfect the inner portion using disinfect material and refixing in original site and testing complete for 04 Nos units of any capacity complete all as specified and directed
12
-
-
Maintenance & complete servicing of Mortury units by electrically disconnecting the units and cleaning the compressor, condensor , piping suction/ discharge suction, fan motor, cooling coils, cooler body and connected accessories with the help of blower unit, cleaning the same with water and caustic soda for condensor and piping unit, painting the cooler base by scrapping out rusted particle and apply two coats of anticorrosive black paint at corroded portion, tighten all nuts bolts, screws etc checking the door beding, electrical controls of the cooling units rectify where necessary, defrost the system dry & disinfect the inner portion using disinfect material and refixing in original site and testing complete for 02 Nos units of any capacity complete all as specified and directed
6
-
-
Taking down the defective compressor unit and supply and installing of new compressor of same type for cool room (by dismantling the unserviceable compressor from composite unit by cutting out copper tubing and electrical connection etc) of capacity 1.5 ton Make- Dan foss, kirloskar, carrier aircon or blue star as suitable at site including bracing work,leak testing vacuumizing Gas charging & testing the site, at required temperature as designed complete all as specified and directed
1
-
-
Taking down the defective compressor unit and supply and installing of new compressor of same type for cold room (by dismantling the unserviceable compressor from composite unit by cutting out copper tubing and electrical connection etc) of capacity 3.5 ton Make- Dan foss, kirloskar, carrier aircon or blue star as suitable at site including bracing work,leak testing vacuumining Gas charging & testing the site, at required temperature as designed complete all as specified and directed
1
-
-
Taking down unserviceable compressor supply and installing the new compressor unit of 2 TR capacity for mortury cabins make- Kirloskar, Carrier, Aircon or Blue star as suitable at site including brazing work vacuumining gas charging leak testing and commissioning the unit to the design temperature complete all as specified and directed
Note for items 3, 4 & 5: Leak testing and gas charging for the units replaced with new compressor is included in the unit rate quoted) Make:- Emerson or equivalent
2
-
-
Material and labour for carrying out Leakage testing of cold storage/cool room/mortury cabinets/ deep freezers by vacuuming the plant with vacuum pump and filling nitrogen gas seperately in compressor and condensor piping etc finding the leakage and rectifying, providing of gaskets packing/brazing, leaking piping where necessary as required for smooth functioning of the plant complete all as specified and directed. (NOTE- Refrigerant gas will be measured seperately)
15
-
-
Material and labour for rewinding of blower motor 0.1 to 0.25 hp with same gauge and turns of copper wire, varnishing and testing of motor complete all as specified and directed
7
-
-
Removing old unserviceable power contactor ML-1.5 and supply & fixing new power contactor ML-1.5 complete all as specified and directed .Make:L&T/Siemens/BCH
7
-
-
Material and labour for LP/HP Cut out after removing to unserviceable LP/HP cut out complete all as specified and directed. Make : Danfoss
7
-
-
Replacement of running capacitor 25 MFD to 45 MFD after removing old unserviceable running capacitor complete all as specified and directed. make : Usha/ Siemens/ Epcos
12
-
-
Replacement of starting capacitor 60MFD to 120MFD after removing old unserviceable capacitor complete all as specified and directed.
16
-
-
Material and labour for oil pressure cut out controls for compressor including taking down old one complete all as specified and directed . Make: MP 55 Indofoss or equivalent.
6
-
-
Removing old unserviceable power contactor ML-2,32A AC3 and supply & fixing new power contactor ML-2, 3pole complete all as specified and directed .Make:L&T/Siemens/BCH
10
-
-
Replacement of old unserviceable thermostat with new thermostat suitable (-)18 deg C to (-) 23deg C cold storage plant complete all as specified and directed.
10
-
-
Removing old unserviceable pilot solenoid valve assembly and providing new pilot solenoid valve assembly for cold room complete all as specified and directed.
13
-
-
Supply and fix in repairs/replacement for defective air curtain sensor suitable for single phase 220 V air curtains of any make complete all as specified and directed.
4
-
-
Material and labour for expansion valve suitable for -18degC to -23degC after removing unserviceable expansion valve in cold room complete all as specified and directed Make :- Danfoss
10
-
-
Supply and fix single phase preventor complete all as specified and directed Make: Minilec
10
-
-
Removing old unserviceable timer, supply and fix new timer of same make and capacity complete all as specified and directed. Make :- L&T, Siemens & Omega
3
-
-
Removing old unserviceable over load relay assembly and supply fixing new overload relay assembly of same make and capacity complete all as specified and directed. Make: L & T or its equivalent
10
-
-
Supply and fix flexible cord type heater 60watt for cold room complete all as specified and directed
5
-
-
Removing the worn out control wiring complete, rewiring with suitable copper conductor cable replacing the lugs starter to compressor motor, fan motor timer HP/LP cut , thermostat complete interlock wiring, checking the complete function of timer, heaters, relays, HP/LP cut outs, thermostat cut out and inter lock wiring system, testing on load and all wiring shall be mounted on cable tray complete all as specified and directed
5
-
-
Supply and fix in repairs ball valve of cast steel flange type of size 25mm bore from the liquid line after pumping down the refrigerant and test for leakages complete all as specified and directed.
4
-
-
Material and labour for replacement of unserviceable / defective existing ampere meter digital type 0-30 Amps with CT of size 96 x 96mm complete all as specified & directed.
1
-
-
Material and labour for replacement of unserviceable / defective existing Volt meter digital type 0-500 Volts with PT of size 96 x 96mm complete all as specified & directed.
1
-
-
Removing old unserviceable condensor coil fan motor with blade assembly and providing new condensor coil fan motor with blade complete suitable for cold room outer unit complete all as specified and directed .
7
-
-
Removing old unserviceable cooling coil fan motor with blade assembly and providing new cooling coil fan motor with blade complete suitable for cold room inner unit complete all as specified and directed .
3
-
-
Taking out old unserviceable condensor and supply & fix new condensor made out of copper pipe and aluminium fins suitable for cold/ cool room including gas charging, leakage checking and testing complete all as specified and directed
5
-
-
Supply & fix in replacement Filter Drier for size 5/8 or 3/8 inch flare size suitable for cold storage/cool room complete all as specified and directed. Make: Sporlan or equivalent
20
-
-
Supply and fix as required at site compressor oil after draining out old oil flushing the compressor chamber and filling oil to the requisite level for cooling equipment complete all as specified and directed
50
-
-
Supply and charge fresh R-22 Mafron refrigerant Gas as required in the cool room/cold storage/ Mortuary/ deep freezer cabinets complete all as specified and directed
200
-
-
Supply & installation for cable tray 300 mm with 50 mm collar height of 16 SWG thickness with cover suitable for laying refrigerant pipes, power & control cables, incl support clamps, rods, bolts, nuts, washers, fastners etc complete all as specified & directed.
50
-
-
Supply & fix in repair wire netting of galvanised steel wire 24 gauge fixed wit tinned tacks of wire staples mesh size 12 mm aparture over entire duct insulation wit 50mm overlap for preventing Rat bites.
50
-
-
Supply & fillig for refrigerant Gas R410a complete all as specified
50
-
-
Supply & fillig for refrigerant Gas R32 complete all as specified
100
-
-
Supply & Filling, Testing and commissioning for Refrigerant Gas R-404a complete all as specified
61
-
-
Taking down the defective compressor unit and supply and installing of new compressor of same type for ductable AC (by dismantling the unserviceable compressor from composite unit by cutting out copper tubing and electrical connection etc) of capacity 5.5 ton Make- Emerson, Dan foss, kirloskar, carrier aircon or blue star as suitable at site including bracing work,leak testing vacuumining Gas charging & testing the site, at required temperature as designed complete all as specified and directed
2
-
-
All as per item no. 100 above, But having capacity 8.5 TR.
4
-
-
All as per item no. 100 above, But having capacity 11.0 TR.
2
-
-
S & F in repairs for sub zero controller with relay,Frontal IP65 rating, 230VAC 2.8VA Max input suitable for cold room/ductable AC having operating temparature range of 0 to +60 degree Celsius fixed to wall/ panels all as specified.
10
-
-
S & F in repairs for cold room temperature display panel of suitable rating including temperature sensor probe fixed/ hanging inside the cold room all as specified and directed
3
-
-
M & L point wiring with 4 sqmm (Nominal area) PVC insulated & unsheathed multistranded FRLSH copper conductor cable (using colour code as per IS), 1100 Volt grade drawn through incl suitable size surface PVC cassing capping (ISI marked) with all accessories & terminated in & incl surface PVC modular box including cover plate and frame of suitable size incl 4 sqmm size PVC insulated & unsheathed multistranded FRLSH copper conductor cable for continious earth conductor (using green colour) and connecting to earth dolly for one industrial metal clad power socket on Independent board for AC.
10
-
-
Supply and fix in repairs electronic circuit (PCB) split type AC of any capacity, any make complete all as specified and directed.
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%