Military Engineer Services Tender
... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 Sep 2024
Closing Date30 Oct 2024
Tender Amount₹ 59,50,000
Costs
EMD
₹ 1,14,250Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_670146_1Bid Award Id
ViewTender No
8605/CWE (NW) Mumbai/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Returning & filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm as in soil complete all as specified & directed .
212
-
-
... More
Material and labour for dry clean sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :- Only compacted thickness of sand will be measured and paid.
94.2
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, class LV Type I, flat, size 250 mm x 150 mm x 40 mm. laid in trenches complete all as specified and directed.
6778
-
-
... More
Supply and fixing, laying in repair PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 4 core 10 Sqmm laid in trenches/ through pipe/ ducts or fixed on wall etc ,complete all as specified and as directed.
835
-
-
... More
Supply & fixing laying in repair PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 4.0 core 25 Sqmm laid in trenches/ through pipe/ ducts or fixed on wall etc complete all as specified and directed .
321
-
-
... More
Supply & fixing laying in repir PVC insulated XLPE, armoured LT cable, 1100 Volts grade with aluminium conductor of size 3.5 core 35 Sqmm laid in trenches/ through pipe/ ducts or fixed on wall etc complete all as specified and directed.
298
-
-
... More
Material and Labour required for taking up loose XLPE cable from wall & refixing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of sizes upto 50 Sqmm 3.5 Core complete fixed on wall with suitable size of clamps with anchor fastner or saddles & screw all as specified and directed.
795
-
-
... More
Supply and fixing in repair MCB DP 63 Amps adjustable type with Breaking capacity 16 KA. (B series) .
48
-
-
... More
Supply and fixing in repair MCB of size 40 Amps, 240 Volts B series all as specified and directed by engr-in-Charge.
68
-
-
... More
Supply and fixing in repair MCBs of Size 6 to 32 Amps, 240 Volts all as specified and directed by engr-in-Charge.
125
-
-
... More
Supply and fixing in repair MCB 3P/4P 63 Amps adjustable type Breaking capacity 16 KA. (B series) .
15
-
-
... More
Supply and fixing in repair MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA all as specified and directed by engineer in charge
8
-
-
... More
Supply and fixing in repair MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA all as specified and directed by engineer in charge
9
-
-
... More
Supply and fixing in repair MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA all as specified and directed by engineer in charge
10
-
-
... More
Supply and fixing hydroblast Marine 5050 LED Deck Lightining Beveled Downward pitch technology, Black casing,warm white colour LED compatible with Hydoblast controllers with necessary arrangement for connecting the lights including terminal/junction boxes, ceiling roses for connection of lights complete all as specified and directed by Engineer-in-charge.
12
-
-
... More
Supply and fixing in repair LED Post top Lantern with die cast aluminium spigot,spun AL powder coated top cover, AL clear acrylic and with holder and IP 65 protection with all accseeories including PCC foundation tapper plug bolts,Nuts,Screwed, complete including taking down of Old Light complete all as specified and directed by engr-in-charge.
8
-
-
... More
Supply and fixing in repairs LED light 9/10 Watt (min 100 lumen /watt) square shaped integral decorative LED bollard IP 65/IK10 With all acessories including PCC foundation tapper plug bolts, nuts, screwed complete including taking down of old light complete all as specified and directed by Engineer-in-Charge and taking down old light complete
11
-
-
... More
Supply and fixing in repairs LED light 9/10 Watt (min 100 lumen /watt) City Cube LED bollard P with IP 65/IK10 With CCT Ranges from 3000K to 4000K and all acessories including PCC foundation tapper plug bolts, nuts, screwed complete including taking down of old light complete all as specified and directed by Engineer-in-Charge.
12
-
-
... More
Supply and fixing in repairs LED Post Top HERITAGE TYPE Ideal to Light up Parks/Streets, Gardens light 20 Watts (min 100 lumen/watt) integral decorative IP 65/IK10 With all acessories including PCC foundation tapper plug bolts, nuts, screwed complete including taking down of old light complete etc complete all as specified and directed by Engineer-in-Charge.
44
-
-
... More
Supply and fixing in repairs LED Post Top TERRIAN TYPE Ideal to Light up Gates, Gardens light 40 Watts (min 100 lumen/watt) integral decorative IP 65/IK10 With all acessories including PCC foundation tapper plug bolts, nuts, screwed completeincluding taking down old light etc complete all as specified and directed by Engineer-in-Charge.
16
-
-
... More
Supply and fixing in repairs LED Post Top GLOBE TYPE Ideal to Light up Gates, Gardens light 25 Watts (min 100 lumen/watt) integral decorative IP 65/IK10 With all acessories including PCC foundation tapper plug bolts, nuts, screwed complete etc complete including taking down old light fitting all as specified and directed by Engineer-in-Charge.
46
-
-
... More
Supply and fixing in repairs LED post top integral pole mounted decorative LED post top 50Watt with IP66/IK10 protection complete including taking down old light fittings all accessories including complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Material and Labour required for checking serviceability of all garden lights and if minor fault find then inform to the concerned JE E/M and repair that garden light and all as specifien and directed by engineer-in-charge.
Note-: Quoted rate shall include minor spare parts which is required for the serviceability of that light.
180
-
-
... More
Supply and lay in repair 40 mm dia GI tubing "light" grade for cable protection at road crossing/ hard standing/ plinth protection/ on the pole etc complete all as specified and directed.
45
-
-
... More
Supply and fix in repair FRP type looping box of size 300x200x125 mm including necessary arrangement to fix the looping box with the suitable size of cable glands with entry, nuts,bolts, washers flat iron etc comprising of the followings:- Make of looping box - (a) MCB,63 Amps, TP (10 KA) (C series) - 01 No. (b) MCB 5 to 30 Amps, SP (10KA) (C series)-01 No
(c) Neutral link - 01 No
145
-
-
... More
Supply and fixing in repair PVC insulated, stranded copper conductor of size 3 core 2.5 Sqmm in connection of FRP type looping box to light fitting connector, passing through GI pipe / tubular pole complete with fixing arrangement all as specified and directed.
580
-
-
... More
Dismantling connections & Taking out broken, damaged / rusted street light poles of any kind / make complete alongwith light fittings including necessary excavation, breaking PCC, returning/ filling and removing surplus soil out of MD land complete all as specified and directed.
22
-
-
... More
Material & labour for preparation of deteriorated /rusted Feeder Pillers, scraping and applying two coat of aluminium paint and marking the panel numbers with Black/ yellow paint complete all as specified and directed by Engineer-in-Charge.
85
-
-
... More
Supply and fixing Steel tubular swaged street light poles complete with cast iron base plate ,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 9.0 mtr long and painting with two coat of aluminium paint over one coat of primer on exposed surface of pole all as specified and directed by Engr-in-Charge.
(NOTE-Excavation & PCC will be measured and paid separately)
22
-
-
... More
Material & labour PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, base foundation filling concrete including necessary form work.
1.25
-
-
... More
Material & labour for PCC 1:3:6 type C2 using 20 mm graded aggregate block masonry with solid block ,exc 10 cm in width and setting in mortar complete for coping of pole including necessary from work and fair finish to the exposed surface area without using extra cement complete all as specified and directed.
10.88
-
-
... More
Material & labour PCC 1:2:4 type D2 using 40 mm graded stone aggregate for coping of the poles as in foundation, filling mass concrete, coping including necessary form work.
2.2
-
-
... More
Supply & fixing in repairs LED Street Light 75 Watt (min 100 lumen/watt) capacity in aluminium pressure die cast housing , High Power LED, secondary optics, IP 65/66, 10KV, including wiring complete all as specified & directed.
28
-
-
... More
Supply & fixing in repairs LED Street Light fittings 90 Watt (min 100 lumen/watt) capacity in aluminium pressure die cast housing , High Power LED, secondary optics, IP 65/66, 10KV SPD including wiring complete all as specified & directed.
38
-
-
... More
Supply & fixing in repair LED Flood light fittings 120 Watt (min 100 lumen/watt) capacity in aluminium pressure die cast housing , High Power LED, secondary optics, IP 65/66, 10KV SPD, including wiring complete all as specified & directed.
21
-
-
... More
Supply & fixing in repairs LED Flood light fittings 75 Watt (min 100 lumen/watt) capacity in aluminium pressure die cast housing, High Power LED, secondary optics, IP 65/66, 10KV SPD, including wiring complete all as specified & directed.
18
-
-
... More
Supply & fixing in repairs LED Flood light fittings 250 Watt capacity in aluminium pressure die cast housing , High Power LED, secondary optics, IP 65/66, 10KV SPD, including wiring complete all as specified & directed.
14
-
-
... More
Supply and fixing High intensity LED flood light fittings 400 W, specially designed for sports/Search etc. Alluminium housing , polycarbonate secondary optic cover, IP 66, 10KV SPD and wired with all acessories.
8
-
-
... More
Taking down U/S high mast light fittings of height 15 meter after lowering the arm including taking out winch, gear box, from high mast pole.
4
-
-
... More
Material and labour required for oiling, greasing and servicing of steel wire rope , complete double drum winch system, control gear box, checking the internal wiring and balancing the arms duly vertical in position for smooth functioning of high mast tower complete all as specifed and directed.
4
-
-
... More
Supply and fix in repair, replacement of complete control gear box for high mast lights of any height with all assessories as existing including alignment i.e. truly vertical in position, 2 point suspension system with steel wire rope 6 mm dia and suitable aviation light as existing complete all as specified
4
-
-
... More
Material & labour for switching on & off the mast fittings by automatic control using astronomical timer and contactor for automatic switch on & off of mast at present time over current and latch mechanism including 4 core PVC flexible cable 2.5 Sqmm multi stranded copper with 3 pin metal clad socket to plug the supply for luminaries shall be mounted on PVC rigid board of suitable size provided in the base compartment of mast to terminate the incoming power supply cable from junction box to incoming luminaries complete outdoor type weather proof with MCB 63 Amps 4 pole 35 KA for incoming.
6
-
-
... More
Supply and fix CC LED driver suitable for 45-75 W high power LED street light fittings, Vin- 230V, AC, 50Hz , Vout- 68-80V DC, PF 0.95, Current (I in) : 1.25A, Current (I out) : 1.0-1.5A with IP rating 66 duly taking down the existing UNSV driver complete all as specified.
58
-
-
... More
Supply and fix CC LED driver suitable for 90-165 W high power LED street light fittings, Vin- 230V, AC, 50Hz , Vout- 88-93V DC, PF 0.95, Current (I in) : 1.7A, Current (I out) : 1.5A with IP rating 66 duly taking down the existing UNSV driver complete all as specified.
68
-
-
... More
Supply and fix CC LED driver suitable for 400 W high power LED street light fittings, Vin- 230V, AC, 50Hz , Vout- 100-120V DC, PF 0.95, Current (I in) : 0.110A, Current (I out) : 0.63 A duly taking down the existing UNSV driver complete all as specified.
15
-
-
... More
Supply and fix CC LED driver suitable for 250 W high power LED light fittings, Vin- 230V, AC, 50Hz , Vout- 32-42V DC, PF 0.95, Current (I in) : 1.25A, Current (I out) : 1.0-1.5A with IP rating 66 duly taking down the existing UNSV driver complete all as specified.
28
-
-
... More
Supply & fix in repair install testing and commissioning of feeder pillar box ,outdoor type cubical shape,three phase, 4 wire, aluminium bus bar rating 400 amps for phases and 200 amps for neutral made out of CRCA sheet ,3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust, weather and vermin proof , provn for ventilation , angle iron frame and four legs of thick angle iron , grouted on PCC 1:2:4 type B1 foundation work of suitable height from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar,switch gear etc complete all as specified & directed and comprising of following including necessary PCC , cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc complete all as specified & directed. (i) MCCB 4 Pole, 415V, fixed type, 250Amps with breaking capacity 25KA : 01 Nos (incoming). (ii) MCCB 3/4 Pole, 415V, fixed type, 160 Amps with breaking capacity 16KA : 02 Nos (outgoing) (iii) MCB 3/4 Pole, 415V, fixed type, 40 Amps with breaking capacity 16KA : 6 Nos (outgoing)
1
-
-
... More
Supply & fix in repair install testing and commissioning of feeder pillar box ,outdoor type cubical shape,three phase, 4 wire, copper bus bar rating 600 amps for phases and 300 amps for neutral made out of CRCA sheet ,3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust, weather and vermin proof , provn for ventilation , angle iron frame and four legs of thick angle iron , grouted on PCC 1:2:4 type B1 foundation work of suitable height from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar,switch gear etc complete all as specified & directed and comprising of following including necessary PCC , cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc complete all as specified & directed. (i) MCCB 4 Pole, 415V, adjustable thermal type, 400Amps with breaking capacity 25KA : 01 Nos (incoming). (ii) MCCB 4 Pole, 415V,adjustable thermal type, 200 Amps with breaking capacity 16KA : 01 Nos (outgoing) (ii) MCCB 4 Pole, 415V,adjustable thermal type, 125 Amps with breaking capacity 16KA : 01 Nos (outgoing) (ii) MCCB 4 Pole, 415V,adjustable thermal type, 100 Amps with breaking capacity 16KA : 01 Nos (outgoing) (ii) MCCB 4 Pole, 415V,adjustable thermal type, 63 Amps with breaking capacity 16KA : 02 Nos (outgoing) (iii) MCB 4 Pole, 415V, adjustable thermal type, 32 Amps with breaking capacity 16KA : 2 Nos (outgoing)
1
-
-
... More
Supply and Fix in repair street light/Decorative Light timer astronomical type 230V,50Hz,1 Channel Control and automatic operating modes, IP rating 20 and fix timing according to sunrise and sunset which automatically switches on and switches off street Light/Decorative Light all as specified and directed by Engineer-in-Charge.
25
-
-
... More
Material & labour for in repair Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.5 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6 mm with the help of bolts, nuts, check nuts and washers of galvanised iron or steel, including necessary excavation, PCC 1:3:6 type D2 and PCC cover 1:2:4 type B1 watering arrangement with GI pipe funnel, jali, complete all as specified and shown in electrical plate No.3 including connection to the earthing test point and testing on completion.
18
-
-
... More
Material and Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed by engineer-in-charge.
415
-
-
... More
Material & labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip.
325
-
-
... More
Material & labour for preparation of deteriorated /rusted poles, scraping and applying two coat of aluminium paint after one coat and marking the pole numbers with Black/ yellow paint complete all as specified and directed by Engineer-in-Charge.
325
-
-
... More
Material & labour required for attending & restoring the short circuits/sparking/tripping complaints for street lights and landscaping lights and removing the burnt out parts, making proper insulation with insulating materials etc complete all as specified and directed by Engr - in - Charge.
465
-
-
... More
Material & labour for replacement of in repair old deteriorated street light brackets made out of GI pipe of 40 mm dia light grade, single arm of suitable size and shape complete including fabrication, fitting fixtures all as specified and directed at site by Engr - in- Charge
40
-
-
... More
Material & labour for replacement of in repair old deteriorated street light brackets made out of GI pipe of 40 mm dia light grade, Double Arm of suitable size and shape complete including fabrication fitting fixtures all as specified and directed at site by Engr - in- Charge
35
-
-
... More
Material & labour for in Repair/replacement coping of existing street light /Garden Lights poles complete with PCC 1:2:4 D2 type 20 mm graded stone, painting after PCC work complete all as specified and directed at site by Engr - in- Charge.
185
-
-
... More
Supply, Installation, Testing and commissioning of heritage aesthetic look (RAL Color Code 9007) post top luminaire (including light pole and lights as per description) having symmetrical distribution beam angle of 120°X120° (±5%) with housing material of Die-cast aluminum, powder-coated finish, PC cover; system wattage not exceeding 33W and system lumen output of not less than 3900 lumens with efficacy not less than 110 lumens/W. CCT of 3000K and CRI=70 with SDCM5. Weight not more than 8.5 kgs. Fixture shall operate in a temperature range of 0°C to 50°C . Fixture shall have input voltage for 100 – 277 VAC, 50/60 Hz. Lifetime should be at least 50,000 burning hours at L70 at 40 degree centigrade ambient. Fixture shall equipped with total IP65 protection and mechanical impact of minimum IK08. The fixture should be capable of surge protection upto 20kV minimum with salt spray test of 50hr. Luminaire driver should be EMI/EMC Compliant Luminaire dia must be minimum 460mm. LM79 and LM80 reports must be submitted along with the bid. Luminaire and driver should be of same make. Luminaire ies file (photometry file) must also be submitted along with the bid. Should include Decorative poles with base plate and all associated items made out of MS pipe (finished with P.U. painted shade) of 301 Cm height and window at the bottom for space for MCB and terminal block for fixing LED post top integral mounted decorative LED light post suitable for 40/25/20 mm dia GI bend to desired shape as directed by Engineer-in-Charge. NOTE :- Excavation & PCC will be measured and paid seperately
18
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements