Military Engineer Services Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date7 Feb 2025
Closing Date28 Feb 2025
Tender Amount₹ 49,52,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down/ up for repair centrifugal pump sets from foundation, separating pump and motor, disconnecting the water and electric connnection and transporting to work shop, opening the pump for inspecting all parts to identify defective parts, cleaning/ servicing & greasing including refixing and replacement unsv bearings for drive end and non drive end, Gun metal bushes, impeller, shafts, shaft seal, worn out gland packing, gland nut bolt & replacement of damaged foundation bolts, reassembling of pumping set and transporting back to pump house, installing, connecting with water & electric connection and testing for performance complete for following capacities.

-

-

-

... More
Pump capacity upto 10 HP

4

-

-

... More
Pump capacity 10 to 15 HP

2

-

-

... More
Pump capacity 30 HP to 40.0 HP

1

-

-

... More
Taking down/ up for electric motor by disconnection from terminal & pump coupling & foundation complete removing of motor, carrying to workshop and return after opening motor removing burnt copper wire, cleaning all parts throughly rewinding motor with same gauge and same No of turns of super enamelled copper wire including insulating materials like varnishing, heating etc and replacement unsv Ball bearings, Terminal plate, Foundation bolts and reassembling the electric motor by connecting with pump and electrical connections testing on completion of following capacities complete all as directed :-

-

-

-

... More
Motor capacity upto 10 HP

4

-

-

... More
Motor capacity 10 HP to 15 HP

2

-

-

... More
Motor capacity 30 HP to 40.0 HP

1

-

-

... More
M & L for taking out pumps alongwith motor from foundation, disconnecting the water and electric connection and transporting to work shop, opening the pump for inspecting all parts to identify defective parts, cleaning/ servicing and greasing including replacement of unsv bearings for drive and non drive end, bushes, impeller, bearing, shafts, shaft seal, worn out gland packing and rewinding of electric motor by disconnection from terminal removing burnt copper wire, cleaning all parts throughly rewinding motor with same gauge and same No of turns of super enamelled copper wire including insulating materials like varnishing, heating etc and replacement unsv Ball bearings, Terminal plate, Foundation bolts and reassembling the electric motor by connecting with pump and electrical connections testing on completion of following capacities complete all as directed :-

-

-

-

... More
Pump Set capacity 0.5/1/1.5 HP

2

-

-

... More
Pump Set capacity upto 2/3/5 HP

4

-

-

... More
Pump Set capacity upto 7.5 HP

2

-

-

... More
Pump Set capacity upto 12.5 HP

1

-

-

... More
Supply & fix in replacement of following sizes DOL starter in sheet metal enclosure complete all as specified and as directed.

-

-

-

... More
230 volts 50 Hz single phase for electric motor of capacity upto 2 HP

3

-

-

... More
415 volts 50 Hz three phase for electric motor of capacity 3 HP

2

-

-

... More
415 volts 50 Hz Three phase for electric motor of capacity 7.5 HP

2

-

-

... More
415 volts 50 Hz Three phase for electric motor of capacity 10 HP

1

-

-

... More
Supply & fix in replacement of following sizes Fully Automatic Star Delta Starter in sheet metal enclosure all as specified and as directed.

-

-

-

... More
415 volts 50 Hz Three phase for electric motor of capacity 7.5 HP

1

-

-

... More
415 volts 50 Hz Three phase for electric motor of capacity 12.5 HP

2

-

-

... More
415 volts 50 Hz Three phase for electric motor of capacity 40 HP

1

-

-

... More
Supply & Fix in replacement Submersible pump controller starter in sheet metal enclosure, 415 Volts Three phase, suitable for motor of cap upto 7.5 HP complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of automatic pressure pump electrically operated 240 volts, 50 Hz fixed to 20/25mm dia pipe confirming to Model No PB 200 Make Wilo Mather of platt or equivalent model in kirloskar / KSB/ Beacon / Cromton greaves/ Jyoti necessary electrical connections and GI fittings complete all as specified and directed.

1

-

-

... More
M & L for disconnect the electric cable from panel and taking out the unserviceable/ burnt out submersible pump set of capacity upto 3.0/7.5 HP from the bore with the help of chain pully and tripod and transporting to work shop for carrying out rewinding the motor with same gauge and same no of turns of with water proof PVC insulated copper wire of existing guage and size to achieve the specified/ required RPM after taking out old unserviceable winding wire, cleaning/ repairing damaged slots and also replacement of impellers, bearings, thrust bearings, gun metal bushes and NRV as per existings of pump, and installing/ inserting back in position connecting up water and electric connections complete all as directed. Note:- Supply only Submersible cable & nylon rope etc willl be measured paid seperately.

1

-

-

... More
Supply only in replacement for lowering the submerssible copper conductor mutistraned cable of size 3 core x 2.5 Sq mm with necessary connections from Motor to starter complete all as specified.

40

-

-

... More
Supply only in replacement for lowering the submerssible copper conductor mutistraned cable of size 3 core x 4 Sq mm with necessary connections from Motor to starter complete all as specified.

40

-

-

... More
Supply only in replacement Nylon rope 8 and 12 mm dia with necessary locking arrangements complete all as directed.

20

-

-

... More
Material and labour for repairs/servicing to suction sweeper assembly of capacity upto 3 HP including replacement of unserviceable parts such as motors, wire brushes and replacing of axle with bearings including front and rear wheels, working handle, brush etc and painting with 2 coats of epoxy paint over a coat of epoxy primer complete all as directed.

2

-

-

... More
Supply only in replacement nylon rope of size 40mm dia good quality after removing from the suction sweeper complete all as specified & directed.

60

-

-

... More
Supply, installation, testing and commissioning smart level water level controller/ indicator (5 levels) digital type, along with sensor complete with water level controller, 0.75 sqmm 10 core sensing cable 100 mtrs long and all other connective accessories including dismantling of old unserviceable one complete all as specified and directed.

1

-

-

... More
Comprehensive Maintenance for filteration plant -03 nos at ASI Swimming Pool (Outdoor ) (preventive, breakdown, Monthly, Quarterly, Half yearly maintenance). Taking out and removing existing sand, gravel, accumulated mud etc. from Filter media form the pressure filters including cleaning of filter thoroughly inside etc and keeping safe custody in good condition of filter media as of different sizes as suitable for reuse and remaining unusable qty to be removed/ disposal of to a distance not exceeding 100 Mtr complete including testing and commissioning all as directed by Engineer-in-Charge. Note : (a) Replacing the filter media such as sand, gravel and cleaning the gravels. Rejected gravels to be replaced with new gravels as directed by Engineer-in-Charge which will be measured and paid for separately under relevant items. (b) Inspection/ checking the pressure gauges, control valves including connecting pipes etc. damaged/corroded nuts bolts, arresting leakages by replacing gasket with new parts. Welding as required etc/ deemed to be included quoted rates. (c) testing and commissioning the plant all as directed by Engineer-in-charge complete.

1

-

-

... More
Supply only Fresh Nature River Sand Filter media 0.4 mm to 0.8 mm size complete

0.2

-

-

... More
Supply only Fresh Gravel Filter media in filter beds for the following sizes complete all as specified and as directed by Engineer -in-charge

-

-

-

... More
Fresh Gravel filter media 25 mm to 50 mm

0.2

-

-

... More
Fresh Gravel filter media 12 mm to 25 mm

0.1

-

-

... More
Fresh Gravel filter media 03 mm to 12 mm

0.2

-

-

... More
Fresh Gravel filter media 01 mm to 03 mm

0.3

-

-

... More
Supply only TCCA - 90 (TRICHLOROISOCYANURIC ACID) high strength chlorinator of opproved make for water disinfectant in factory sealed HDPE container (40 to 50 Kg each) all as directed.

600

-

-

... More
Supply only alum crystal free from impurity class I suitable for swimming pools

300

-

-

... More
Supply only Copper sulphate in 40/50Kg packaging complete all as specified & directed. Note for item no. 23 to 35 : These items will be added to the swimming pool by DEL/M&O staff at the time of installations.

200

-

-

... More
S&F in replacement Cast iron Double Flanged Non- Rising Spindle type Sluice valve having stainless steel to AISI 410 Spindle & Gun Metal Working parts, manually Handwheel operated PN -1.6 with ISI Marked, Flange ends drilled complete all as specified and as directed.

-

-

-

... More
80mm dia

4

-

-

... More
100mm dia

3

-

-

... More
150mm dia

1

-

-

... More
Supply and fixing in replacement cast iron foot valve, ISI marked both end flanged with nut bolt washers and rubber gasket ISI marked, installation, testing of following sizes complete all as directed and specified .

-

-

-

... More
80 mm dia.

1

-

-

... More
100 mm dia

1

-

-

... More
Supply and fix in replacement gun metal gate valve with iron wheel head screwed both ends including dismantling the old unserviceable gate valve for iron pipe of size :-

-

-

-

... More
15 mm bore

6

-

-

... More
20 mm bore

4

-

-

... More
25 mm bore

5

-

-

... More
40 mm bore

4

-

-

... More
50/65 mm bore

4

-

-

... More
Supply and fix in replacement non return valve or reflex valve both end flanged ISI marked including making new flanged joints with 3 mm thick rubber gasket with necessary bolts, nuts, washer etc of suitable size of following size complete all as specified and as directed

-

-

-

... More
50 mm bore

2

-

-

... More
80 mm bore

1

-

-

... More
Maintenance and servicing of Sluice valve, Non return Valve, foot valve of any size by disconnecting the water connnection opening the valves for inspection of all parts to identify defective parts, cleaning/ servicing & greasing including refixing and replacement unserviceable parts, shafts, shaft seal, rubber washers, gates, rubber seal, worn out gland packing, gland nut bolt & replacement of damaged bolts, reassembling of valves, installing, connecting with water & electric connection and testing for performance complete all as specified and as directed.

10

-

-

... More
M & L in replacement connecting pieces one end flanged and other end socket or spigot and bell mouth pieces one end flanged other end tapering as bell mounth, CI Bends tapers, Tees, pieces (Single or double branch) any Type and angle/ radius and straight connecting pieces for CI/GI/DI Pipe upto 150 mm bore complete all as specified and as directed.

50

-

-

... More
M & L in replacement Bends, Tapers, Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged any type and angle/ radius and straight connecting pieces for CI/GI/DI Pipe upto 150 mm bore complete all as specified and as directed.

50

-

-

... More
M & L for MS work for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated with including two coat of aluminum paint and coat of primer including dismantling of old unsviceable MS Framed works complete all as directed. Note: (i) Scaffolding, ladder etc for welding of MS ladder/Angle for Semi UG sump/ OH tank up to 20 Mtr to be arrange by the contractor. and the rates quoted by the contractor shall be deemed to be included for the above and nothing shall be paid extra on this account

2

-

-

... More
M & L for construction of Brick Masonry Valve Pit, Chanmber one Brick thick wall in cement mortar 1:4 on 100mm thick PCC 1:4:8 (using 40mm graded stone aggregate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (Type B1 using 20mm graded stone aggregates) Block of size 230 x 200 x 100 mm including applying two coats of Anti-corrosive Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary Earth Work and excavation in Soft/Loose Soil including demolition of old unserviceable Valve Pit of following sizes complete all as specified and as directed.

-

-

-

... More
600 x 600 x 600 mm (Internal Dimension)

4

-

-

... More
900 x 900 x 900 mm (Internal Dimension)

4

-

-

... More
1000 x 1000 x 1000 mm (Internal Dimension)

2

-

-

... More
2000 x 2000 x 2000 mm (Internal Dimension)

2

-

-

... More
M & L for preparing old painted surfaces of Pumps, motors, Panels, pipes suction/delivery line by scraping and removing old paints, rust etc and painting with two coats of synthetic enamel paint complete all as specified and directed. (i) Pump & Motar set complete with suction & delivery line - 03 (ii) Honoblock Pump & motar set complete with suction and delivery line - 15 (iii) Panels -02

20

-

-

... More
M & L for Preparation of new or previously untreated steel surfaces over 10mm width or girth of any description, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.

20

-

-

... More
Taking out all loose dirt, scales etc from the inner walls of under ground sumps by scraping with wire brush, cleaning with disinfectant chemicals, bleaching powder etc and providing two coats of white wash after preparing the surface thoroughly including writing date of cleaning of tank on outer side of walls complete all as directed for the following capacity of tank. Note: (i) Scaffolding, brushes, bleaching powder, lime etc for cleaning the internal surface of under ground pump to be arrange by the contractor. and the rates quoted by the contractor shall be deemed to be included for the above and nothing shall be paid extra on this account (ii) Pumping arrangement for pumping out water below wash out shall be arrange by the contractor.

-

-

-

... More
80000 ltrs at OLD NDA pump house

1

-

-

... More
136000 ltrs at OLD NDA pump house

1

-

-

... More
170000 litres at ASI Pump House

1

-

-

... More
Taking out all loose dirt scales etc from the inner walls of over head reservoir of the following capacities upto 20 metre high staging by scraping with wire brushes, cleaning with disinfectant chemicals, bleaching powder etc and providing two coats of whie wash after preparing the surface thoroughly including writing date of cleaning on outer side of walls complete all as directed complete for the sumps following capacity :- Note: (i) Scaffolding, ladder, brushes, bleaching powder, lime etc for cleaning the internal surface of under ground pump to be arrange by the contractor. and the rates quoted by the contractor shall be deemed to be included for the above and nothing shall be paid extra in this account (ii) Pumping arrangement for pumping out water below wash out shall be arrange by the contractor.

-

-

-

... More
1.2 lakh Gallons at OLD NDA complex Pump house

1

-

-

... More
Surface dressing in soft / loose soil not exeeding 15 cm deep, across the pipe lines with including site clearance, cutting and cleaning of branches / bushes / plants / grass obstructing to the pipe lines / valves / chambers / sumps / OHTs on either sides and water supply Installation area including disposal of materials up to a distance not exceeding 50 mtr complete all as specified and directed by Engr-in-Charge.

400

-

-

... More
M & L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in filling and mass concrete for foundation of Pumps / motors/ Pipes including embedding necessary MS frame work / MS channel complete all as specified and directed.

2

-

-

... More
M & L for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground earth pit not less than 2.25 Mtr deep below normal ground level, with top edge of the plate vertically to a depth not less than 1.5 Mtr below ground level connected to and including GI strip 32 x 6 mm and GI pipe 40 mm dia light grade for protection upto the extent of 7.5 Mtr as earthing strip by means of GI bolts, nuts and washers etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Part-I including RCC cover with RCC 1:2:4 type B1 and MS angle iron frame, watering arrangement with GI pipe 20 mm dia medium grade and MS funnel, concrete pit with including necessary excavation and earth work in any type of soil and testing on completion etc complete. Note :- GI strip beyond 7.50 Mtr will be measured and paid separately.

8

-

-

... More
M & L in replacement earth continuity conductor or main earthing lead fixed to wall as recessed and chasses or burried on ground or drawn in conduit / suitable protection pipe fixed to poles or any indicated situtation for loop earthing as required with 32 mm x 6 mm GI flat strip including necessary welding , jointing / GI nuts, washers and bolts etc complete all as directed.

25

-

-

... More
M & L in replacement of integral LED aviation obstruction light (Twin), yellow pointed with die-cast aluminium alloy housing set of two, heat resistant clear thick glass and accessories with LED lamp complete all as directed

1

-

-

... More
M & L for Sub main wiring with 2 runs of single core 2.5 Sqmm PVC insulated unsheathed multistranded 1100 Volts grade with copper conductor drawn through and including non-metallic 20 mm PVC rigid conduit , ISI marked and its accessories on wall / roof including one run of single core 2.5 Sqmm PVC insulated unsheathed multistranded 1100 Volts grade with copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified. Note:- Two run of 2.5 Sqmm conductor & one run of 2.5 Sqmm earth conductor & One run of conduit will be measured as on RM

30

-

-

... More
S & F in replacement of old First Aid box complete at various E/M installations complete all as directed

2

-

-

... More
M & L for Periodical checking of Pumping sets complete, testing and adjusting all moving parts, lubricating, checking of alignment, checking of unusual sounds, heating, water leakages, etc complete all as directed

5

-

-

... More
Supply O-Tolidine Solution in 500 ML Bottle (For Chlorine Test), complete all as directed

2

-

-

... More
Supply only water hardness measuring equipment in built glass electrode of high sensitivity of 0.2 mm thickness digital display, self calibrated, measuring range upto 14.0 ppm resolution 0.01 pH, accuracy 0.01 pH all as directed.

2

-

-

... More
Supply & lay in replacement 15 mm dia GI pipe medium grade including all fittings fixed to walls/ceiling or laid in floors complete all as directed

130

-

-

... More
Supply & lay in replacement 20 mm dia GI pipe medium grade including all fittings fixed to walls/ceiling or laid in floors complete all as directed

130

-

-

... More
Supply & lay in replacement 25 mm dia GI pipe medium grade including all fittings fixed to walls/ceiling or laid in floors complete all as directed

150

-

-

... More
Supply & lay in replacement 40 mm dia GI pipe medium grade including all fittings fixed walls/ceiling or laid in floors complete all as directed

140

-

-

... More
Supply & lay in replacement 50 mm dia GI pipe medium grade including all fittings fixed walls/ceiling or laid in floors complete all as directed

140

-

-

... More
Supply & lay in replacement 80 mm dia GI pipe galvanized, medium grade including all fittings fixed walls/ceiling or laid in floors complete all as directed

140

-

-

... More
Supply & lay in replacement 100 mm dia GI pipe galvanized, medium grade including all fittings fixed walls/ceiling or laid in floors complete all as directed

108

-

-

... More
Supply & lay in replacement Unplasticised PVC pipes of pressure rating 10 Kgf/sqcm fixed complete to walls, ceilings or in floors etc.including all fittings of size 15 mm dia complete all as directed

50

-

-

... More
Supply & lay in replacement Unplasticised PVC pipes of pressure rating 10 kgf/Sqcm fixed complete to walls, ceilings or in floors etc.including all fittings of size 20 mm dia complete all as directed

50

-

-

... More
Supply & lay in replacement Unplasticised PVC pipes of pressure rating 10 kgf/Sqcm fixed complete to walls, ceilings or in floors etc.including all fittings of size 25 mm dia complete all as directed

50

-

-

... More
Supply & lay in replacement Unplasticised PVC pipes of pressure rating 10 kgf/Sqcm fixed complete to walls, ceilings or in floors etc.including all fittings of size 40 mm dia complete all as directed

50

-

-

... More
M&L for LED sign board/ Display board etc on LED board minimum of size1.2m x 0.3 m, suitable for Outdoor application, water proof, Indoor Brightnes, Auto/Manual, can be viewed from long distance, High quality chip, without flickering, display ability like scrolling text, Random text, Numeric, Date and time, animated text, long lasting, unbreakable, high brightness, scratch resistant and Plug & ready to use, wall mounted, WIFI/Bluetooth Programming Interface Method, Multi Colour, complete with all accessories and including wall mounting bracket of suitable size including clamps, nut bolts etc. including all accessories internally pre-wired and connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed

2

-

-

... More
Material and labour for suction sweeper assembly of capacity upto 3 HP including parts such as motors, wire brushes and axle with bearings including front and rear wheels, working handle, brush etc and painting with 2 coats of epoxy paint over a coat of epoxy primer complete all as directed.

1

-

-

... More
M&L for Replacement of old unsv lightening conductor remove from OH Tank and S&F aluminium strip 25 mm x 3 mm complete with saddle and fixing screw /insulators for roof or down conductor or fixed to pole or any other indicated situation for loop earthing etc, as required including making test point and testing complete all as specified and as directed.

20

-

-

... More
M&L for Replacement of old unsv air termination rod from OH tank and S&F Single pointed Air Termination aluminium rod 12mm dia and 300mm long and supported with GI pipe med grade 40 mm dia not less than 2 mtr for fixing air termination rod above the over head tank staging with necessary fixing arrangement complete all as directed

1

-

-

... More
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc

10

-

-

... More
M&L for 75 mm thick cement concrete 1:3:6, type C2, using 40 mm graded stone aggregate in floor/ plinth protection finish the surface even and smooth without using extra cement including filling the expansion joints with bitumenfiller/ filler boards complete as specified

100

-

-

... More
M&L for Machine Pressed Precast Concrete glossy interlocking Paver block any shape and size confirming to IS of 600 mm thickness M-35 grade with grey cement and pigment including 25 mm thick sand cushioning complete all as specified.

100

-

-

... More
Supply and fixing Mechanical joint of made out of CI of thickness not less than 10 mm fabricated as per existing site requirement including long MS nut, bolt, rubber gasket, cutting/fixing of pipe in position of any size CI/GI/DI pipe with the help of manually as well as mechanical T&P complete including taking down old existing mechanical joint all as directed of following sizes :-

-

-

-

... More
40/50 mm bore dia

4

-

-

... More
80/100 mm bore dia

4

-

-

... More
150 mm bore dia

2

-

-

... More
M & L for attending the emergency repairs to leakage / damage GI/UPVC/PPR Pipe of size 20/25 mm dia including carrying out minor repairs to arrest the leakages all as directed including necessary excavation, earth work, returning filling of excavated soil and removal of water by manually/ mechanically and jointing with and including new fittings, accessories such as saddle clamp with rubber packing and nuts, bolts, washers etc union / sockets/Tee/Tee reducer etc as required basis complete all as specified and as directed.

8

-

-

... More
M & L for attending the emergency repairs to leakage / damage GI/UPVC/PPR Pipe of size 40/50 mm dia including carrying out minor repairs to arrest the leakages all as directed including necessary excavation, earth work, returning filling of excavated soil and removal of water by manually / mechanically and jointing with and including new fittings, accessories such as saddle clamp with rubber packing and nuts, bolts, washers etc union/sockets/Tee/Tee reducer etc as required basis complete all as specified and as directed..

8

-

-

... More
M & L for attending the emergency repairs to leakage / damage CI/GI/DI Pipe of size 80/100 mm dia including carrying out minor repairs to arrest the leakages all as directed including necessary excavation, earth work, returning filling of excavated soil and removal of water by manually / mechanically and jointing with and including new fittings, accessories such as saddle clamp with rubber packing and nuts, bolts, washers etc union/sockets/Tee/Tee reducer etc as required basis complete all as specified and as directed.

3

-

-

... More
M & L for attending the emergency repairs to leakage / damage CI/GI/DI Pipe of size 150/200 mm dia including carrying out minor repairs to arrest the leakages all as directed including necessary excavation, earth work, returning filling of excavated soil and removal of water by manually/mechanically and jointing with and including new fittings, accessories such as saddle clamp with rubber packing and nuts, bolts, washers etc union/sockets/Tee/Tee reducer etc as required basis complete all as specified and as directed.

2

-

-

... More
M & L for cutting existing CI/GI/DI tubing for alteration or additions of sizes including screwing existing GI tubing for arresting leakages, tapping or making new connections etc complete all as specified. Note: Excavation and earthwork will be measured and paid separately.

-

-

-

... More
15 mm bore dia

10

-

-

... More
20 mm bore dia

12

-

-

... More
25 mm bore dia

10

-

-

... More
40/50 mm bore dia

10

-

-

... More
80/100/150 mm bore dia

10

-

-

... More
Burning out unsv / leakage lead joint in position, including removing old lead including necessary excavation and earth work in soils, returning, filling and removal of accumulated water by using pump of following sizes complete all as directed. Note : (i) M & L Lead joint will be measured and paid separetly under respective items.

-

-

-

... More
80 mm dia

1

-

-

... More
100 mm dia

1

-

-

... More
150 mm dia

1

-

-

... More
M & L for Run Lead joint in spigot and socket pipes and fittings of size 80 mm dia including necessary caulking the spun yarn as required complete all as specified.

1

-

-

... More
M & L for Run Lead joint in spigot and socket pipes and fittings of size 100 mm dia including necessary caulking the spun yarn as required complete all as specified.

1

-

-

... More
M & L for Run Lead joint in spigot and socket pipes and fittings of size 150 mm dia including necessary caulking the spun yarn as required complete all as specified.

1

-

-

... More
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in Soft / loose soil for laying of pipe etc complete all as directed.

128

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soil complete all as directed

124

-

-

... More
Removing excavated meterial (Soil) to a distance not exc 50 mtr and depositing where as directed at a level not exceeding 1.5 mtr above the starting point complete all as specified.

4

-

-

... More
Cutting of Road/hard standing for taking out of unsviceable water pipe line and making new connection and making good with PCC (1:2:4) using 12.5mm graded stone aggregate including making good the disturbed portion to match the existing complete all as directed.

1

-

-

... More
M & L for running welding of thickness not exc 6 mm complete all as directed.

10

-

-

... More
Material and labour for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of old rusted surface of steel exc 10 cm width/grith, at any height of tank and water supply vertical pipes of pumping and distribution pipe lines as per different colour code including marking of arrow for flowing of water with approved color shade paint complete all as and directed. Note :- Scaffolding and connected allied items etc to be arranged by the contractor the rate quoted by the contractor shall be deemed to be included.

20

-

-

... More
M&L for Pipe Support for all types of pipes including hangars / fastners / elbows/ supports / tees complete all as directed

5

-

-

... More
Maintenance and servicing of DG sets once in a month including attending faults on call basis for normal repairs including replacement of defective & worn out parts by new spares such as filters, gaskets, V-belts, Engine oil, Coolant, rubber hoses, door hinges/ lock, worm drive clamps, nuts, bolts and cleaning of alternator and attending faults of AMF panels etc and greasing of bearings of engine and alternator, checking of batteries, adding distilled water, checking and topup of oil and coolant levels as directed by Engineer-in Charge. Note : 1. Spares required for above maintenance will be measured and paid separately under relevant item. 2. Servicing to be carried out as per manufacturer instruction

-

-

-

... More
D.G Set 400 KVA, Engine make: Kirloskar, Location : AFMC DJ Block

9

-

-

... More
D.G Set 320 KVA, Engine make: Greaves, Location : AFMC IRC

9

-

-

... More
D. G . Set 320 KVA, Engine make: Greaves, Location : AFMC Main Sub Stn

9

-

-

... More
D. G . Set 320 KVA, Engine make: Greaves, Location : AFMC Boys Hostel Pump house

9

-

-

... More
D. G . Set 250 KVA, Engine make: Kirloskar, Location :AFMC Sub Stn (Main Bldg)

9

-

-

... More
D. G . Set 250 KVA, Engine make: Greaves, Location : AFMC Boys Hostel Pump house

9

-

-

... More
D. G . Set 200 KVA, Engine make: Greaves, Location : AFMC Sub Stn (Main Bldg)

9

-

-

... More
D. G . Set 180 KVA, Engine make: Greaves, Location : Ashok Chakra Library

9

-

-

... More
D. G . Set 160 KVA, Engine make: Kirloskar, Location :AFMC Sub Stn (Officers Mess)

9

-

-

... More
D. G. Set 160 KVA, Engine make: Kirloskar, Location : AFMC Dhanwantari Auditorium

9

-

-

... More
D. G. Set 160 KVA, Engine make: Kirloskar, Location : AFMC GJ Block

9

-

-

... More
D. G . Set 100 KVA, Engine make: Kirloskar, Location : AFMC Apramaya Block

9

-

-

... More
D. G . Set 100 KVA, Engine make: Greaves, Location : AFMC CCM

9

-

-

... More
D. G . Set 62.5 KVA, Engine make: Greaves, Location : AFMC Girls Hostel

9

-

-

... More
D. G . Set 62.5 KVA, Engine make: Cummins, Location : AFMC 5 maj 6 capt Dimond Jubilee Pump House

9

-

-

... More
D. G . Set 40 KVA, Engine make: Kirloskar, Location : AFMC BTD Store New

9

-

-

... More
D. G . Set 30 KVA, Engine make: Kirloskar, Location : Nursing Mess

9

-

-

... More
D. G . Set 25 KVA, Engine make: Kirloskar, Location : AFMC 450 OR Pump House

9

-

-

... More
D. G . Set 15 KVA, Engine make: Kirloskar, Location : ALC Pump House

9

-

-

... More
D. G . Set 15 KVA, Engine make: Greaves, Location : AFMC 264 OR Pump House

9

-

-

... More
D. G . Set 7.5 KVA, Engine make: Kirloskar, Location : AFMC Ration Store

9

-

-

... More
Supply only diesel filter element with O ring, suitable for following capacities of DG sets

-

-

-

... More
D. G . Set 15/7.5 KVA

6

-

-

... More
D. G . Set 25/30/40 KVA

6

-

-

... More
D. G . Set 62.5 KVA

4

-

-

... More
D. G . Set 100 KVA

4

-

-

... More
D. G . Set 160/180/200/250 KVA

14

-

-

... More
D. G . Set 320 /400 KVA

8

-

-

... More
Supply only oil filter element with 'O' ring, suitable for following capacities of DG sets :-

-

-

-

... More
D. G . Set 15/7.5 KVA

3

-

-

... More
D. G . Set 25/30/40 KVA

3

-

-

... More
D. G . Set 62.5 KVA

2

-

-

... More
D. G . Set 100 KVA

2

-

-

... More
D. G . Set 160/180/200/250 KVA

7

-

-

... More
D. G . Set 320 /400 KVA

4

-

-

... More
Supply only by pass filter element with O ring suitable for following capacities of DG sets :-

-

-

-

... More
D. G . Set 160/180/200 KVA

5

-

-

... More
D. G . Set 250/320 KVA

5

-

-

... More
D. G . Set 400 KVA

1

-

-

... More
Supply only air filter element suitable for following capacities of DG sets :-

-

-

-

... More
D. G . Set 7.5/ 15 KVA

3

-

-

... More
D. G . Set 25/ 30/ 40 KVA

3

-

-

... More
D. G . Set 62.5 KVA

2

-

-

... More
D. G . Set 100 KVA

2

-

-

... More
D. G . Set 160/180/200 KVA

5

-

-

... More
D. G . Set 250/320 KVA

5

-

-

... More
D. G . Set 400 KVA

1

-

-

... More
Supply only fan belt suitable for following capacities of DG sets :-

-

-

-

... More
D. G . Set 7.5/ 15 KVA V BELT A55

3

-

-

... More
D. G . Set 25/ 30/ 40 KVA V BELT A-48 1252 LENGTH

3

-

-

... More
D. G . Set 62.5 KVA V belt 48X1262 Length

2

-

-

... More
D. G . Set 100 KVA belt (AVX 10 1500 ) SPZ

3

-

-

... More
D. G . Set 160/180/200 KVA (AV X13X 1562 length)

4

-

-

... More
D. G . Set 250/320 KVA SPB V BELT (106 SPB 1340)

2

-

-

... More
D. G . Set 400 KVA BELT V SECTION (BX 58- PITCH LENGTH 1520

1

-

-

... More
Supply only belt for battery charging alternator for following capacities of DG sets :-

-

-

-

... More
D. G . Set 100 KVA SPZX SECTION BELT ( FOR ALTERNATOR- 24V, LP 1180)

2

-

-

... More
D. G . Set 160/180/200 KVA V TYPE AX-58

5

-

-

... More
D. G . Set 250/320 KVA V BELT COGGED( AVX 10 - 1136)

2

-

-

... More
D. G . Set 400 KVA V' WRAPPED BELT, SPB AR 1170

1

-

-

... More
Supply only rubber hose pipe set for water/Air circuit complete with clamps, suitable for following capacities of DG sets :-

-

-

-

... More
D. G . Set 15/30/ 40/50 KVA

3

-

-

... More
D. G . Set 62.5 KVA

2

-

-

... More
D. G . Set 100 KVA

2

-

-

... More
D. G . Set 160/180/200 KVA

4

-

-

... More
D. G . Set 250/320 KVA

2

-

-

... More
D. G . Set 400 KVA

1

-

-

... More
Supply only engine oil, multi grade 15W / 40.

600

-

-

... More
Supply only Petroleum jelly.

2

-

-

... More
Supply only distilled water for lead acid battery

120

-

-

... More
Supply only for coolent for DG Sets.

450

-

-

... More
Supply only for waterr pump for DG Sets.

-

-

-

... More
D. G . Set 15/30/ 40 KVA

2

-

-

... More
D. G . Set 50/62.5 KVA

1

-

-

... More
D. G . Set 100/160/180/200 KVA

2

-

-

... More
D. G . Set 250/320/400 KVA

1

-

-

... More
Supply only brass battery terminals set of 02 Nos suitable for 12 Volt batteries, complete all as directed.

10

-

-

... More
Supply only battery lead/cable PVC copper conductor, size of 10 sqmm and 1 mtr long suitable for 12 Volt batteries, complete all as directed.

10

-

-

... More
M&L cleaning/removing dirt and impurities particles of diesel tank and replacing damaged parts, nuts and bolts including cleaning and rectifying leakages of diesel for effective function of plant complete all as directed.

22

-

-

... More
S & F in repairs Water temperature gauge including sensor and cable complete all as directed.

3

-

-

... More
Dismantling of radiator from the DG set for overhauling & cleaning descaling with acid removal of leakage, welding brazing & refixing it duly repaired complete all as directed by Engineer- in- Charge for the following capacities DG sets.

-

-

-

... More
D. G . Set 15/30/ 40/50 KVA

5

-

-

... More
D. G . Set 62.5 KVA

2

-

-

... More
D. G . Set 100 KVA

2

-

-

... More
D. G . Set 160/180/200 KVA

5

-

-

... More
D. G . Set 250/320 KVA

4

-

-

... More
D. G . Set 400 KVA

1

-

-

... More
Calibration of FIP and injectors from the authorised dealer including petty repairs to make the FIP functional for the following capacities of DG sets including necessary spares required for smooth functioning of FIP :-

-

-

-

... More
D. G . Set 7.5/ 15 KVA

2

-

-

... More
D. G . Set 25/ 30/ 40 KVA

2

-

-

... More
D. G . Set 62.5 KVA

2

-

-

... More
D. G . Set 100 KVA

2

-

-

... More
D. G . Set 160/180/200 KVA

2

-

-

... More
D. G . Set 250/320 KVA

2

-

-

... More
D. G . Set 400 KVA

1

-

-

... More
M&L for repair / overhauling of self starter including replacement of carbon brushes, bearing, bushes, rewinding of armature and field etc. and varnishing complete all as directed for the following capacity :-

-

-

-

... More
12 Volts self starter for DG set of capacity 7.5/15/25/30/40 KVA

5

-

-

... More
12 Volts self starter for DG set of capacity 100/ 62.5 KVA

2

-

-

... More
24 Volts self starter for DG set of capacity 160/ 180/ 200 / 250/ 320/ 400 KVA

5

-

-

... More
M & L for repairing of battery charging alternator engine mounted with replacement of any of the unserviceable part such as rectifier with voltage regulator, diode plate, carbon brushes for the following capacities complete all as directed :-

-

-

-

... More
12 Volts capacity

2

-

-

... More
24 Volts capacity

2

-

-

... More
Supply & fix in repairs battery charging circuit suitable for 12 Volt, DC in existing DG set panel board including addition/ alteration in wiring system complete with auto transformer, diodes, filter circuit, condensers, DC Ammeter, DC Volt meter with selector switches and indicating bulbs etc complete all as directed

3

-

-

... More
Supply and fixing in repairs battery charging circuit suitable for 24 Volt, DC in existing DG set panel board including addition alteration in wiring system complete with auto transformer, diodes, filter circuit, condensers, DC Ammeter, DC Volt meter with selector switches and indicating bulbs etc complete all as directed

3

-

-

... More
S & F Manual changeover switch in sheet steel enclosure of rating 630 Amps 4 Pole 415 Volt all as per manufacturer design complete.

1

-

-

... More
S & F Manual changeover switch in sheet steel enclosure of rating 400 Amps 4 Pole 415 Volt all as per manufacturer design complete.

1

-

-

... More
Dismantling the existing unserviceable power contactor 3 phase 3 pole 630 Amps 415Volt, 50 Hz AC, from the AMF panel after disconnecting incoming and out going connections and all control connections including coil connections, and supply and fixing new power contactor 3 phase 3 pole 630 Amps with 2NO+2NC with suitable 415 Volt/ 220 Volt coil as required and connecting both incoming and outgoing connections complete all as directed

1

-

-

... More
Dismantling the existing unserviceable power contactor 3phase 4 pole 500 Amps 415Volts, 50 Hz AC, from the AMF panel after disconnecting incoming and out going connections and all control connections including coil connections, supply and fixing new power contactor 3 phase 4 pole 500 Amps with 2NO+2NC with suitable 415 Volt/ 220 Volt coil as required and connecting both incoming and outgoing connections complete all as directed

1

-

-

... More
Dismantling the existing unserviceable power contactor 3phase 3 pole 400 Amps 415 Volts, 50 Hz AC, from the AMF panel after disconnecting incoming and out going connections and all control connections including coil connections, supply and fixing new power contactor 3 phase 3 pole 400 Amps with 2NO+2NC with suitable 415 Volt/ 220 Volt coil as required and connecting both incoming and outgoing connections complete all as directed

1

-

-

... More
Dismantling the existing unserviceable power contactor 3phase 3 pole 300 Amps 415 Volt, 50 Hz AC, from the AMF panel after disconnecting incoming and out going connections and all control connections including coil connections, supply and fixing new power contactor 3 phase 3 pole 300 Amps with 2NO+2NC with suitable 415 Volt /220 Volt coil as required and connecting both incoming and outgoing connections complete all as directed.

1

-

-

... More
Dismantling the existing unserviceable power contactor 3phase 4 pole 200 Amps 415Volt, 50 Hz AC, from the AMF panel after disconnecting incoming and out going connections and all control connections including coil connections, supply and fixing new power contactor 3 phase 4 pole 200 Amps with 2NO+2NC with suitable 415V/220 V coil as required and connecting both incoming and outgoing connections complete all as directed.

1

-

-

... More
Dismantling the existing unserviceable power contactor 3phase 3/4 pole 100 Amps 415Volt, 50 Hz AC, from the AMF panel after disconnecting incoming and out going connections and all control connections including coil connections, supply and fixing new power contactor 3 phase 3/4 pole 100 Amps with 2NO+2NC with suitable 415 Volt/ 220 Volt coil as required and connecting both incoming and outgoing connections complete all as directed.

2

-

-

... More
Dismantling the existing unserviceable power contactor 3 phase 4 pole 40/63/65 Amps 415Volt, 50 Hz AC, from the AMF panel after disconnecting incoming and out going connections and all control connections including coil connections, supply and fixing new power contactor 3 phase 4 pole 40/63/65 Amps with 2NO+2NC with suitable 415 Volt/ 220 Volt coil as required and connecting both incoming and outgoing connections complete all as directed. Note for item No 104 to 110:-Necessary modifications to the panel including drilling / welding etc as required to fix the contactor shall be carried out by the contactor without any extra cost to Govt.

2

-

-

... More
S & F in repairs Time delay relay suitable for 100/ 110/ 160/ 180/ 200 KVA DG Set complete all as directed

5

-

-

... More
M&L for tappet setting of following capacities of DG sets complete all as specified and as directed

-

-

-

... More
D. G . Set 15/25/30/40 KVA

3

-

-

... More
D. G . Set 62.5 KVA

2

-

-

... More
D. G . Set 100 KVA

2

-

-

... More
D. G . Set 160/180/200 KVA

4

-

-

... More
D. G . Set 250/320 KVA

3

-

-

... More
D. G . Set 400 KVA

1

-

-

... More
Supply and fix in repairs automatic voltage regulator (AVR) 63 KVA to 160 KVA DG set complete as per existing DG sets all as directed

2

-

-

... More
Supply and fix in repairs automatic voltage regulator above (AVR) 160 KVA to 400 KVA DG set complete as per existing DG sets all as directed

2

-

-

... More
Supply and fix in repairs voltage monitor regulator (VMR) 7.5 KVA to 40 KVA DG set complete as per existing DG sets all as directed

3

-

-

... More
Supply and fix in repairs voltage monitor regulator (VMR) 62.5 KVA to 320 KVA DG set complete as per existing DG sets all as directed

3

-

-

... More
Supply and fix in repairs fuel steel braided pipe with benjo bolts and washers having length of 4 mtr long etc of suitable size DG Sets complete all as directed

16

-

-

... More
Supply and fix in repairs control wiring of the DG set up to 160 KVA complete including provision of additional auto cables heavy duty suitable for Gen set application complete all as directed

2

-

-

... More
Supply and fix in repairs voltage monitor regulator(VMR) of DG set 160 KVA to 400 KVA.

2

-

-

... More
Supply and fix in repairs pressure guage 0 to 7 Kg/Sqcm along with sensor and cable and as directed

2

-

-

... More
Supply and fix in repairs lead acid battery 12 Volts 180 AH with initial charging and having indicators to know the status of level of electrolyte complete all as directed.

4

-

-

... More
Supply and fix in repairs lead acid battery 12 Volts 150 Ah with initial charging and having indicators to know the status of level of electrolyte complete all as directed .

4

-

-

... More
Supply and fix in repairs lead acid battery 12 Volts 100 Ah with initial charging and having indicators to know the status of level of electrolyte complete all as directed.

4

-

-

... More
Supply and fix in repairs lead acid battery 12 Volts 80 Ah with initial charging and having indicators to know the status of level of electrolyte complete all as directed.

4

-

-

... More
Supply and fix in repairs solenoid valve suitable for following capacity DG sets for smooth functioning of DG sets complete to the satisfaction of Engineer-in-Charge

-

-

-

... More
D. G . Set 40 KVA

1

-

-

... More
D. G . Set 62.5 KVA

1

-

-

... More
D. G . Set 100KVA

1

-

-

... More
D. G . Set 160/180/200 KVA

2

-

-

... More
D. G . Set 250/320 KVA

1

-

-

... More
D. G . Set 400 KVA

1

-

-

... More
Supply and fix in repair microprocessor based multifunction relay suitable for DG sets operation and showing the various parameters such as Volt, Ampere, frequency, RPM etc complete all as directed

1

-

-

... More
Supply and fix DIN type HRC fuse link type HN of following capacities :-

-

-

-

... More
630 Amps

3

-

-

... More
500 Amps

3

-

-

... More
400 Amps

3

-

-

... More
315 Amps

3

-

-

... More
250 Amps

3

-

-

... More
160 Amps

3

-

-

... More
80 Amps

3

-

-

... More
Dismantling the existing unserviceable alternator up to 250 KVA DG set and Transporting the same to authorised service centre removing the short circuited winding wire fully, cleaning the armature slots carefully and rewinding fully with same gauge copper winding wire, insulating with same grade and class insulating material, varnishing drying out setting back the alternator and transporting back in location, fitted to the DG set including connecting up testing and commissioning all as directed.

1

-

-

... More
Preparation of old painted surfaces of the Canopy/ Frame/ Exhaust Manifold/ Silencer of DG Sets complete degreasing and spray painting the same with two coats of approved synthetic enamel paint of approved shade complete all as directed.

10

-

-

... More
Taking out turbocharger from 400/320/250/ 200 /180 KVA DG Set any make model, cleaning/removing dirt and impurities particles of turbo charger impeller and replacing damaged parts, washers, nuts and bolts and including rectifying leakages completely for effective function of DG Set and re-fix in same position and testing complete all as directed.

5

-

-

... More
M & L for dismantling of lub oil tank replacement of the gaskets and refixing at original position including checking and repair to leakages in the engine side, replacement of unserviceable gasket complete all as directed

12

-

-

... More
M&L for replacement in repair of foudation/vibration pad set (set of 4 Nos) of DG set of cacacity 160 KVA to 400 KVA as per existing make ,model to match as per required size/capacity includig dismentling the same at site by crane or hydraulic jack coplete as specified

5

-

-

... More
S&F in repairs rubber insulating mat 2.5 mm thick,2 mtr long and 1 mtr width complee all as specified

8

-

-

... More
S&F in repairs copper "O" ring for muffler/silencer of DG set 160 KVA to 400 KVA complete all as directed

8

-

-

... More
S&F in repairs copper "O" ring for muffler/silencer of DG set 7.5 KVA to 125 KVA complete all as directed

10

-

-

... More
M&L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 32 x 6 mm galvanised iron or steel strip all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion

7

-

-

... More
M & L for earth continuity conductor or main earthing lead fixed to wall as recessed and chasses or burried on ground or drawn in conduit/suitable protection pipe or any indicated situtation for loop earthing as required with 32 mm x 6mm GI flat strip including necessary welding joints/Pipe/GI nuts and bolts etc complete all as directed.

150

-

-

... More
Supply, laying connecting and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100volts grade, cross-sectional area following sizes

-

-

-

... More
size 25 Sqmm 4 core

50

-

-

... More
size 95 sqmm 3.5 core

20

-

-

... More
Size 150 sqmm 3.5 core

15

-

-

... More
Size 240 sqmm 3.5 core

15

-

-

... More
size 300 sqmm 3.5 core

10

-

-

... More
Supply and fixing in replacement voltmeter 0 to 500 volt AC supply flush mounted type 415 volt AC supply with suitable CTs for conversion factor

4

-

-

... More
Supply and fixing in replacement ammeter 0 to 300 amps with CTS ratio 300/5 flush mounted type 415 volt AC supply

5

-

-

... More
Supply and fix Multifunction meter Confiming to cat No WDM303FDWAX Make L & T or equivalent

4

-

-

... More
Supply and fix Single phase preventor

5

-

-

... More
Supply and fix maual / remote Genrator controller cum supervisory module designrd to control the engine via push buttons on front panel or remotedly operated key switch / digital inputes during all cycles genrator is fully monitored and protected against any faut tand display on the LCD display suitable for DG set of capacity 250/320/400 KVA complete suitble for existing make / model of DG set, testing all as spcified.

2

-

-

... More
Supply and fix mechanical Fuel indicator suitable for DG set

6

-

-

... More
Supply and fix voltage monitoring relay , three phase suitable for DG set of make L & T or equivalent

4

-

-

... More
Supply and fix in repairs, MCCB 630 Amps , FP , 415 Volts rupturing capacity 35 KA, 50 Hz including spreader terminals complete all as specified and directed

1

-

-

... More
Supply and fix in repairs, MCCB 400 Amps , FP , 415 Volts, rupturing capacity 35 KA, 50 Hz including spreader terminals complete all as specified and directed

1

-

-

... More
Supply and fix in repairs, MCCB 350 Amps , FP , 415 Volts, rupturing capacity 35 KA, 50 Hz including spreader terminals complete all as specified and directed

1

-

-

... More
Supply and fix in repairs, MCCB 250 Amps , FP , 415 Volts, rupturing capacity 35 KA, 50 Hz including spreader terminals complete all as specified and directed

1

-

-

... More
Supply and fix in repairs, MCCB 200 Amps , FP , 415 Volts, rupturing capacity 35 KA, 50 Hz including spreader terminals complete all as specified and directed

1

-

-

... More
Supply and fix in repairs, MCCB 160 Amps , FP , 415 Volts, rupturing capacity 35 KA, 50 Hz including spreader terminals complete all as specified and directed

1

-

-

... More
Supply and fix in repairs, MCCB 125 Amps , FP , 415 Volts, rupturing capacity 35 KA, 50 Hz including spreader terminals complete all as specified and directed

1

-

-

... More
Supply and fix in repairs, MCCB 63/100 Amps , FP , 415 Volts, rupturing capacity 35 KA, 50 Hz including spreader terminals complete all as specified and directed

3

-

-

... More
Supply and fix in repairs fuse base suitable for fuse link Din type fuse suitable for HRC fuse conforming to cat No SK 90405 type HN size 000&000 , 415 volt AC supply of capacity 160 amps (Make L&T. CG or standard )

4

-

-

... More
M&L in repairs fuse base suitable for fuse link Din type fuse suitable for HRC fuse conforming to cat No SK 90406 type HN size 1 &1 B , 415 volt AC supply of capacity 250 amps (Make L&T. CG or standard )

4

-

-

... More
M&L in repairs fuse base suitable for fuse link Din type fuse suitable for HRC fuse conforming to cat No SK 91051 type HN size 2 & 3 , 415 volt AC supply of capacity 800 amps (Make L&T. CG or standard )

6

-

-

... More
Supply and fixing in repair LED type piolet indicator lamp (R,B,Y) with integral circuit suitable for LT panels / AMF panel complete all as specified and directed.

10

-

-

... More
Supply and fix white dry asbestos rope 8mm size

25

-

-

... More
Supply only silver paint of burger make

4

-

-

... More
S&F in repair/ replacement of Electric Smoke/ Heat/ Optical Detector, conventional type, size not less than 10 mm dia, 46 mm height with base weight not less than 139 gm per set with base, operating voltage 24 V, opearating Temp 0 degree to 50 degree C, humidity range 0-95 % RH non condensing current 35 MA maximum sensitivity 2.66 + 1.11 % obscuration confirming to CE & EN 54 standards, fixed complete to RCC ceiling inside the building including all fixing materials junction box etc Make ZICOM/Everday or equivalent make ISI marked.

10

-

-

... More
Supply & Lay armoured cable 1.5 Sq mm 2 Core,copper conductor for fire alarm system between and inside different rooms, fixed with and including saddles on wall/ceiling surface in and including 20 mm dia ERW steel heavy grade fixed O wall /ceiling withsaddles and all other material required for laying/fixing complete all as specified and directed.

10

-

-

... More
M&L for complete servicing,checking of all wiring,detetction of faults as occured,making serviceble of fire alarm panel four zones i.e. 15 Nos alarm intiating circuits, type class 'A' or 'B' end of line 3.9K loop powered device current 1.8 a alarm current 500 mA double outputs. (i) Checking of alarm relay, change over voltage free contacts. (ii) Checking of fault realy, change over voltage free contacts duly monitorised by means of line for sounders (iii) Checking ofAuxilary power out, having autonomy with and including 2 No 12 V 7 AH batteries and terminals etc (iv)Setting of 12 hours on standby and Setting of 30 minutes in alram coneition detection lines duly protected from short cirucuiting, suitable for audio and visual alam indications, power input 230 Volts AC + 15% 50/50Hz optional standy power 24 V DC through batteries panel conforming to CE and EN -54 part 2&4 standars, complete assembly housed in a steel housing with hinged remaovable locking door and having paints finish mak CATEC model no XF-C or equivalent make ISI marked, fixed complete inside the control statuion including all fixing material as required at site complete all as specified and directed.

1

-

-

... More
Supply and fixing of hose box made of 18 gauge MS sheet 800mm x 600mmx 250mm with double door with 4 mm thick glass door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside yard complete all as specified and directed.

3

-

-

... More
Supply and fix 63 mm dia 15 mtr long CP hose confirming to IS 636 complete with male and female coupling.

3

-

-

... More
M & L for AMC / repair of voltage stablizer by opening the case of stablizer and check electronic circuit board and bulging capacitors, removing faluty electronic parts and cleaning circuit board with cleaning agent and refixing after repair and testing output voltage

1

-

-

... More
Supply and fix Water pump assembly for 400/320 KVA DG set radiator confirming to cat No KV8.182.10.0.00 of Kirloskar make

1

-

-

... More
Supply and fix in replacement cubical indoor type, weather proof, AMF Control panel fabricated out of 2 mm thick CRCA MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring etc Mechanically and electrically interlocked 2 Nos 4 pole power contactors of 125 Amps rating mounted side-by-side on a base plate for changeover of engine and main supply, 2 Nos of 100 Amps 35 KA, 4 pole MCCB with overload relay range of appropriate rating for incoming mains supply and engine alternator set supply control including static battery charger of suitable rating with auto cut off facility for charging the battery from mains including AC and DC wiring. Microprocessor based Genset controller and monitoring unit for Mains and DG set supply with AMF with all required standard controls, relays, protective systems, digital type Multi functional Meter with displays, indicator lamps for various functions all as specified and directed suitable for40 KVA DG set. Note: (a) Adequate space shall be provided for cable entry and exit (Minimum 4 Nos of cable of 3.5 core 120 Sqmm cable) shall be provided in the AMF panel. (b) Necessary modifications to the inside DG set including drilling / welding etc as required to fix the contactor shall be carried out by the contactor without any extra cost. .

1

-

-

... More
Supply and fix in replacement cubical indoor type, weather proof, AMF Control panel fabricated out of 2 mm thick CRCA MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring etc Mechanically and electrically interlocked 2 Nos 4 pole power contactors of 400 Amps rating mounted side-by-side on a base plate for changeover of engine and main supply, 2 Nos of 250 Amps 35 KA, 4 pole MCCB with overload relay range of appropriate rating for incoming mains supply and engine alternator set supply control including static battery charger of suitable rating with auto cut off facility for charging the battery from mains including AC and DC wiring. Microprocessor based Genset controller and monitoring unit for Mains and DG set supply with AMF with all required standard controls, relays, protective systems, digital type Multi functional Meter with displays, indicator lamps for various functions all as specified and directed suitable for 250 KVA DG set. Note: (a) Adequate space shall be provided for cable entry and exit (Minimum 4 Nos of cable of 3.5 core 185 Sqmm cable) shall be provided in the AMF panel. (b) Necessary modifications to the inside DG set including drilling / welding etc as required to fix the contactor shall be carried out by the contactor without any extra cost. .

1

-

-

... More
Supply and fix in replacement cubical indoor type, weather proof, AMF Control panel fabricated out of 2 mm thick CRCA MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring etc Mechanically and electrically interlocked 2 Nos 4 pole power contactors of 250 Amps rating mounted side-by-side on a base plate for changeover of engine and main supply, 2 Nos of 200 Amps 35 KA, 4 pole MCCB with overload relay range of appropriate rating for incoming mains supply and engine alternator set supply control including static battery charger of suitable rating with auto cut off facility for charging the battery from mains including AC and DC wiring. Microprocessor based Genset controller and monitoring unit for Mains and DG set supply with AMF with all required standard controls, relays, protective systems, digital type Multi functional Meter with displays, indicator lamps for various functions all as specified and directed suitable for160 KVA DG set. Note: (a) Adequate space shall be provided for cable entry and exit (Minimum 4 Nos of cable of 3.5 core 120 Sqmm cable) shall be provided in the AMF panel. (b) Necessary modifications to the inside DG set including drilling / welding etc as required to fix the contactor shall be carried out by the contactor without any extra cost. .

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.